+ All Categories
Home > Documents > 156 MITCHELL STREET, NORTHCOTE · • timber floors to comply with as1684.2 -2010, as1684.3 -2012,...

156 MITCHELL STREET, NORTHCOTE · • timber floors to comply with as1684.2 -2010, as1684.3 -2012,...

Date post: 01-Feb-2021
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
21
Area Analysis Site Area Building Area Paving / Driveways m2 m2 Permeability Total Site Coverage m2 m2 49.03% 244.4 222.40 479.50 22.00 Ground Floor Studio m2 Total Ground Private Open Space m2 m2 Total Building Area m2 m2 Unit 222.4 222.4 166.10 56.30 1 132.7 Project: Client: Municipality: Stage: MITCHELL STREET 156 MITCHELL STREET, NORTHCOTE STACEY & TONY 02.03.2018 156 MITCHELL STREET, NORTHCOTE Project Status DAREBIN WORKING DRAWINGS- BUILDING PERMIT-WD03 Sheet List - Construction Sheet Number Sheet Name A00 COVER SHEET A01 GENERAL NOTES A02 EXISTING GROUND FLOOR PLAN A03 EXISTING SITE PLAN A04 EXISTING ROOF PLAN A05 PROPOSED DEMOLITION PLAN A06 PROPOSED GROUND FLOOR PLAN A07 PROPOSED DIMENSIONED GROUND FLOOR PLAN A08 PROPOSED SITE PLAN A09 PROPOSED ROOF PLAN A10 PROPOSED ELEVATIONS A11 PROPOSED ELEVATIONS 2 A12 PROPOSED SECTION A13 DETAIL SECTION A14 PROPOSED ELECTRICAL PLAN A15 PROPOSED WINDOW & DOOR SCHEDULE A16 3D VIEW- GLAZING A17 3D VIEWS-1 A18 3D VIEWS-2 A19 3D VIEWS-3 A20 Detail GARDEN AREA 152 M2 SITE AREA 479.50 M2 GARDEN AREA COVERAGE 31.7 %
Transcript
  • Area AnalysisSite AreaBuilding AreaPaving / Driveways

    m2m2

    PermeabilityTotal Site Coverage

    m2

    m249.03%

    244.4

    222.40479.50

    22.00

    Ground FloorStudio

    m2

    Total GroundPrivate Open Space

    m2m2

    Total Building Area

    m2

    m2

    Unit

    222.4

    222.4

    166.1056.30

    1

    132.7

    Project:

    Client:

    Municipality:

    Stage:

    MITCHELL STREET156 MITCHELL STREET,

    NORTHCOTE

    STACEY & TONY

    02.03.2018

    156 MITCHELL STREET, NORTHCOTE

    Project Status

    DAREBIN

    WORKING DRAWINGS-BUILDING PERMIT-WD03

    Sheet List - ConstructionSheet

    Number Sheet NameA00 COVER SHEETA01 GENERAL NOTESA02 EXISTING GROUND FLOOR PLANA03 EXISTING SITE PLANA04 EXISTING ROOF PLANA05 PROPOSED DEMOLITION PLANA06 PROPOSED GROUND FLOOR PLANA07 PROPOSED DIMENSIONED GROUND FLOOR PLANA08 PROPOSED SITE PLANA09 PROPOSED ROOF PLANA10 PROPOSED ELEVATIONSA11 PROPOSED ELEVATIONS 2A12 PROPOSED SECTIONA13 DETAIL SECTIONA14 PROPOSED ELECTRICAL PLANA15 PROPOSED WINDOW & DOOR SCHEDULEA16 3D VIEW- GLAZINGA17 3D VIEWS-1A18 3D VIEWS-2A19 3D VIEWS-3A20 Detail

    GARDEN AREA 152 M2SITE AREA 479.50 M2

    GARDEN AREA COVERAGE 31.7 %

  • NOTES (GENERAL):• DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS.• SITE DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.• ALL ARCHITECTURAL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH

    ALL CONSULTANTS' DOCUMENTS: STRUCTURAL ENGINEERING, ENERGY RATINGS, SOIL TESTS, FIRE ENGINEERING AND MECHANICAL ENGINEERING.

    • REFER TO STRUCTURAL ENGINEER'S DOCUMENTATION FOR FOOTING/FOUNDATION DETAILS AND FOR PREPARATION OF EXCAVATIONS.

    • ALL WORKMANSHIP AND MATERIAL SHALL CONFORM TO ALL RELEVANT CODES AND VICTORIAN BUILDING REGULATIONS AND BUILDING CODE OF AUSTRALIA.

    • BUILDER AND BUILDING CONTRACTORS SHALL VERIFY EXISTING SITE CONDITIONS PRIOR TO COMMENCEMENT OF ANY SITE WORKS.

    • ALL ELECTRICAL WIRING TO BE PROVIDED BY A REGISTERED ELECTRICIAN.• IF IN DOUBT ASK, DO NOT GUESS.• CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE

    COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.• ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR

    CLARIFICATION AND APPROVAL IN WRITING.• THE BUILDER SHALL TAKE ALL NECESSARY STEPS TO ENSURE THE

    STABILITY OF NEW AND EXISTING STRUCTURES DURING ALL WORKS• THE BUILDER SHALL ENSURE FOR THE GENERAL WATER TIGHTNESS OF

    ALL NEW AND EXISTING WORKS

    SOIL CLASSIFICATION:• REFER TO SOIL REPORT.

    GROUND WORKS:• EXCAVATE FOR FOOTINGS TO MINIMUM 100mm ONTO FIRM FOUNDATION

    WITH MIN. 100kpA BEARING CAPACITY. REFER TO ENGINEER'S DETAILS.• FOOTINGS TO BE FOUNDED AT THE MINIMUM DEPTHS INDICATED IN THE

    SOIL REPORT• FOOTINGS NOT TO ENCROACH ON BOUNDARIES AND EASEMENT LINES.• NEW STORMWATER PIPE TO BE CONNECTED INTO EXISTING

    STORMWATER SYSTEM AND DISCHARGE TO PUBLIC STORM WATER DRAINAGE SYSTEM ACCORDING TO LOCAL AUTHORITIES REQUIREMENTS.

    DRAINAGE:• ALL DRAINS SHALL COMPLY WITH ALL RELEVANT STANDARDS AND

    APPROPRIATE REGULATORY BODIES AND DISCHARGE IN ACCORDANCE WITH THE RELEVANT CITY COUNCIL'S REQUIREMENTS.

    • STORM WATER DRAINS GENERAL 90dia PVC• STORM WATER DRAINS EXCEEDING 6 INLETS OR UNDER

    RESIDENCE/VEHICLE PAVING 100dia PVC• AGRICULTURAL DRAINS 90 PVC SLOTTED• SEWER DRAINS 100mm PVC• SILT PITS (AG TO SWD) 350mm SQUARE CONCRETE LID• JUNCTION PITS 450mm SQUARE BRICK OR CONCRETE• ALL DRAINAGE SHALL COMPLY WITH ENGINEERING DRAWINGS IF

    SUPPLIED AND TAKE PRECEDENCE OVER THESE SPECIFICATIONS.

    PLUMBING:• BUILDER SHALL ALLOW FOR THE FITTING OFF AND CONNECTION OF ALL

    PLUMBING FIXTURES INDICATED ON PLANS. BUILDER SHALL ALSO ALLOW FOR THE SUPPLY AND INSTALLATION OF 2 EXTERNAL WATER TAPS TO LOCATIONS DIRECTED BY THE OWNER. DOWN PIPES, GUTTERS, SUMP & RAIN HEAD SIZES TO AS3500 - 2003

    • PRESSURE EQUIPMENT TO COMPLY WITH AS1200 - 2000• TECHNICAL SPECIFICATIONS FOR PLUMBING AND DRAINAGE PRODUCTS

    TO COMPLY WITH AS5200 - 2006• ALL PLUMBING WORK TO BE PROVIDED BY A REGISTERED PLUMBER.• WASTE FROM KITCHEN SINK AND OTHER SANITARY FITTINGS (SIZE TO BE

    ESTABLISHED BY REGISTERED PLUMBER) TO BE DISCHARGED TO PUBLIC SEWERAGE SYSTEM

    FOUNDATIONS:• ALL FOUNDATIONS TO COMPLY WITH AS2870 - 2011• REFER TO ENGINEER'S DRAWINGS FOR FULL DETAILS.• ALL FOUNDATIONS SHALL BE INSPECTED BY THE BUILDING INSPECTOR

    PRIOR TO PLACING CONCRETE.• ANY VARIATION IN FOUNDATION MATERIAL FROM THAT SPECIFIED TO BE

    NOTIFIED TO THE ENGINEER AND OWNER.• ALL REINFORCEMENT IN FOOTINGS AND PAD FOOTINGS SHALL BE

    INSPECTED BY THE BUILDING INSPECTOR PRIOR TO POURING CONCRETE.• ALL CONCRETE SHALL BE 25MPa MIN. OR AS SPECIFIED IN STRUCTURAL

    ENGINEER'S DETAIL. IT SHALL BE PROPERLY VIBRATED AND WORK TO BE DONE TO AS1480 - 1975

    CONCRETE:• ALL CONCRETE SHALL COMPLY WITH ALL RELEVANT CODES AS3600 -

    2009, AS2870 - 2011, AS1379 - 2007, AS3610 - 1995 AND IN ACCORD WITH ENGINEERS NOTES AND SPECIFICATION

    • NOTE: REINFORCEMENT BARS SHALL BE SUPPORTED VIA CHAIRS AT A MAXIMUM OF 800mm CENTRES

    TIMBER FRAMING:• ALL TIMBER SHALL COMPLY WITH AS1720.1 - 1997• TIMBER FLOORS TO COMPLY WITH AS1684.2 - 2010, AS1684.3 - 2012,

    AS1684.4 - 2010• TIMBER STRUCTURES - DESIGN METHODS AS1720.1 - 2010• ALL FRAMING TO BE INSPECTED AND APPROVED BY THE BUILDING

    INSPECTOR PRIOR TO COVERING UP ALL TIMBER FRAMING AND MATERIAL.

    • ALL TIMBER TO BE PARTIALLY SEASONED UNLESS NOTED OTHERWISE.• ALL RAFTERS AND ROOF MEMBERS TO BE TIED DOWN TO SUPPORT

    STRUCTURE USING STRAPS, PLATES, CLEATS, ETC BY "PRYDA" OR "TECO" COMPONENTS.

    • BUILDER TO ENSURE THAT ALL WORK IS CARRIED OUT TO THESE SPECIFICATIONS AND NO SPANS OR SIZES TO VARY. NO SPLICES ARE PERMITTED WITHOUT ENGINEER'S WRITTEN CONSENT.

    • ALL EXPOSED BOLTS, FIXINGS, ETC TO BE HOT DIP GALVANISED TO ACCORDANCE WITH AS1650 TO SUIT SITE EXPOSURE CONDITION.

    • ALL TIMBER PRESERVATIVE TO ARCHITECT'S SPECIFICATION TO SUIT EXPOSURE CONDITIONS.

    SUB-FLOOR VENTILATION:• PROVIDE MIN. 6000mm 2 SUB-FLOOR VENTILATION/m OF WALL, AS PER

    PART 3.4.1 OF THE BCA. PROVIDE 'ALETA' OR EQUIVALENT, 230X160 BRASS WIRE VENT. (13,400mm^2 VENTILATION ACHIEVED PER VENT) 6000mm VENTILATION REQUIRED PER METRE OF WALL. VENTS TO BE CALCULATED AS FOLLOWS: (ie. WALL LENGTH 10m x 6000 = 60,000. 60,000 / 13,400 = 4.47 (5) VENTS REQUIRED. 10 / 6 = 1.6m MAX. SPACING) FOR ZONE 3.

    • ALL INSULATION OF PARTICLEBOARD FLOORING TO COMPLY WITH AS1860 - 1998

    WIND LOADS:• ALL STRUCTURES MUST BE TIED DOWN IN ACCORDANCE WITH AS4055 -

    AMDT 1 - 2006 FOR CATEGORY N1 UNLESS OTHERWISE STATED.

    STEEL:• ALL STEEL STRUCTURE TO COMPLY WITH AS4100 - 1998• COMPOSITE STRUCTURES TO COMPLY WITHAS2327 - 2003• COLD FORMED STEEL STRUCTURES TO COMPLY WITH AS4600 - 2005

    INSULATION:• ALL INSULATION TO BE IN ACCORDANCE WITH AS4859.1 - 2009• REFER TO ENERGY RATINGS REPORT FOR FULL INSULATION

    REQUIREMENTS.• WALL INSULATION TO BE ADOPTED IN FIRE RATED WALLS CONTAINING

    TIMBER FRAMING TO BE NON-COMBUSTIBLE.• PROVIDE INSULATION BETWEEN FLOOR AND CEILING TO ACHIEVE A MIN,

    Rw+Ctr RATING OF 50. PROVIDE 50 GLASSWOOL PARTITION BATTS -11kg/m^3

    • RFL TO HAVE A FLAMMABILITY INDEX NOT EXCEEDING 5.

    BRICKWORK:• ALL MASONRY SHALL COMPLY WITH AS3700 - 2001 OR AS4773.1 - 2010 AND

    AS4773.2 - 2010• AS2699 AMDT 1 - 2000: ALL WALL TIES SHALL BE IN ACCORDANCE WITH

    RELEVANT CODES AND SHALL BE GALVANISED. GENERALLY WALL TIES TO BE 600mm CENTERS IN EACH DIRECTION FOR CAVITY MASONRY, FOR MASONRY VENEER: 600x450 FOR 450 STUD WALLS AND 600x600 FOR 600 STUD WALLS AND WITHIN 300mm OF ARTICULATION JOINTS.

    • PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 5000mm CENTERS IN EACH DIRECTION AND WITHIN 300mm OF ARTICULATION JOINTS 2200mm SQ. CLEAR VENTILATION PER 1000mm OF INTERNAL DWARF WALLS.

    • SPACING OF WALL TIES TO TOP AND SIDES OF OPENINGS TO BE HALVED.• MASONRY IN SMALL BUILDINGS DESIGN - AS4773.1 - 2010,

    CONSTRUCTION - AS4773.2 - 2010• BRICKWORK TO BE SELECTED BY CLIENT AND AGREED UPON BY BUILDER

    TOILETS:• PROVIDE 1.2M MIN CLEAR FROM THE DOOR TO THE WC PAN, OR PROVIDE

    LIFT OFF DOOR HINGES.

    GLAZING:• ALL GLAZING SHALL COMPLY WITH AS1288 AMDT 1 - 2006 AND BE

    CERTIFIED ON COMPLETION OF WORKS AS REQUIRED• ALL ROOMS WITHIN 500mm VERTICAL OF THE FLOOR• BATHROOMS WITHIN 1500mm VERTICAL FROM THE BATH BASE• LAUNDRY WITHIN 1200mm VERTICAL FROM THE FLOOR AND/OR WITHIN

    300mm HORIZONTAL FROM ALL DOORS• DOORWAY WITHIN 300mm HORIZONTAL FROM ALL DOORS.• SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS• ALL WINDOWS TO COMPLY WITH AS2047 - 1999TO DOORS AND SIDELIGHTS:• UP TO 0.5m2 - 6.38mm LAMINATED• GREATER THAN 5m2 - 6.38mm LAMINATEDTO WINDOWS:• UP TO 0.1m2 - 6.38mm LAMINATED• UP TO 0.3m2 - 6.38mm LAMINATED• UP TO 2.0m2 - 6.38mm LAMINATED• DOOR AND WINDOWS: UP TO 500mm FROM FLOOR - 6.38mm LAMINATED.• TO BATHROOMS AND ENSUITE WHERE WINDOWS ARE LOCATED OVER

    BATHTUB OR WITHIN SHOWER • ENCLOSURE- SAFETY GLASS.

    WET AREAS:• PROVIDE IMPERVIOUS WALLS, FLOOR AND FLASHINGS TO ALL WET AREAS

    IN ACCORD WITH THE B.C.A. 2008 PART 3.8.1 AND AS3740 - 2010• WET AREA MEMBRANES TO COMPLY WITH AS4858 - 2004• INTERNAL- THE WALL AND FLOOR SURFACES OF A SHOWER ENCLOSURE,

    ADJACENT OR BEHIND A BATH, BASIN TROUGH OR SINK SHALL BE IMPERVIOUS TO WATER IN ACCORDANCE WITH AS 3740 -2010

    • THE WALL SURFACE OF A SHOWER ENCLOSURE SHALL BE IMPERVIOUS TO WATER TO A HEIGHT OF 1800mm

    • THE FLOOR SURFACE TO ALL SANITARY COMPARTMENTS SHALL BE IMPERVIOUS TO WATER.

    • THE WALL IMMEDIATELY ADJACENT OR BEHIND A BASIN, TROUGH OR SINK SHALL BE IMPERVIOUS TO WATER TO A HEIGHT NOT LESS THAN 150MM ABOVE THE FIXTURE.

    • THE FLOOR SURFACE TO ALL SANITARY COMPARTMENTS SHALL BE IMPERVIOUS TO WATER.

    • THE WALL IMMEDIATELY ADJACENT OR BEHIND A BASIN, TROUGH OR SINK SHALL BE IMPERVIOUS TO WATER TO A HEIGHT NOT LESS THAN 150MM ABOVE THE FIXTURE, IF IT IS WITHIN 75mm OF THE WALL.

    • THE JUNCTIONS BETWEEN THE WALLS AND FIXTURES, THE WALLS WITHIN THE SHOWER COMPARTMENT AND THE WALLS AND THE FLOORS ARE REQUIRED TO BE IMPERVIOUS TO WATER.

    • WHERE A SHOWER IS PROVIDED ABOVE THE BATH, FLOOR AND WALL SURFACES WITHIN A RADIUS OF 1500mm FROM THE SHOWERHEAD IS REQUIRED TO BE IMPERVIOUS TO WATER. WHERE NO SHOWER SCREEN IS PROVIDED, THE FLOOR IS REQUIRED TO BE PROVIDED WITH A FLOOR WASTE OUTLET.

    • IF THE SHOWER IS UNENCLOSED, THE WALLS SHALL BE WATER RESISTANT TO A HEIGHT OF 1800MM FOR A LENGTH OF 1500mm FROM EITHER SIDE OF THE SHOWER HEAD.

    • A WATER STOP MUST BE INSTALLED SO THAT ITS VERTICAL LEG WILL FINISH FLUSH WITH THE FLOOR LEVEL TO A 1500mm ARC FROM THE SHOWER HEAD. WHERE A WATER STOP INTERSECTS WITH A WALL OR IS JOINED, THE JUNCTION MUST BE WATERPROOF. FURTHERMORE THE AREA WITHIN THE 1500MM ARC SHALL BE GRADED BETWEEN 1:60 AND 1:80 TO THE SHOWER OUTLET.

    • ALTERNATIVELY, THE WHOLE FLOOR MUST BE WATERPROOFED AND DRAINED TO A FLOOR WASTE AS FOR THE SHOWER AREA. THE FALL OF THE FLOOR OUTSIDE THE SHOWER AREA SHALL BE BETWEEN 1:80 AND 1:100 AND WITHIN THE SHOWER AREA SHALL BE 1:60 AND 1:80. A WATER STOP MUST BE PROVIDED AT THE DOORWAY TO THE BATHROOM.

    VENTILATION:• WHERE APPLICABLE TO HAVE EFFECTIVE AIRWAY OF NOT LESS THAN

    40,000mm^2 AND FIXED INLET VENTILATION OF NOT LESS THAN 8000mm^2 AT LOW LEVEL THROUGH THE EXTERNAL

    • EXHAUST FANS TO ALL GROUND FLOOR APARTMENTS TO BE DUCTED TO OUTSIDE. EXHAUST FANS TO ALL LEVEL 1 APARTMENTS TO VENT INTO CEILING SPACE.

    • PROVIDE CLEARANCE FROM UNDERSIDE OF BEARER TO FINISHED GROUND LEVEL OF 150mm FOR FLOOR WITH STRIP FLOORING OR 200mm FOR FLOORS WITH PARTICLEBOARD FLOORING OR 300mm WHERE IN TERMITE PRONE AREA.

    ELECTRICAL:• PROVIDE NEW CIRCUIT BREAKER BOARDS, WIRING, POWER POINTS AND

    LIGHT OUTLETS AS SCHEDULED TO COMPLY WITH RELEVANT VICTORIAN BUILDING CODES AND AUSTRALIAN STANDARDS. TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.

    STAIRS:• STAIRS SHALL COMPLY WITH 3.9.1 AND 3.9.2 OF NCC BCA 2013• RISERS MIN 115mm, MAX 190mm HIGH.• GOINGS MIN 240mm, MAX 355mm WIDE.• PRIVATE STAIRS (AND 250mm FOR PUBLIC STAIRS), RISERS AND TREADS

    TO BE CONSTANT IN SIZE THROUGHOUT FLIGHT.• PROVIDE 865mm MIN HIGH HANDRAIL TO STAIRS FROM LINE OF NOSING.• PROVIDE CONTINUOUS HANDRAIL TO STAIRS IN ACCORDANCE WITH PART

    3.9.2 OF NCC BCA 2014• PROVIDE 1000mm MIN HIGH HANDRAILS ABOVE FINISHED FLOOR LEVEL TO

    LANDINGS AND BALCONIES.• PROVIDE 1000mm MIN HIGH HANDRAILS ABOVE FINISHED FLOOR LEVEL TO

    CHANGE IN LEVELS EXCEEDING 900mm IN HEIGHT.• PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKID STRIP NEAR EDGE OF

    NOSING.• MAXIMUM OPENING BETWEEN BALUSTRADES NOT TO EXCEED 125mm.

    ENSURE MAXIMUM GAP BETWEEN RISES NOT TO EXCEED 125mm OR USE CLOSED RISES.

    • HANDRAILS TO COMPLY WITH 3.9.2.4 OF BCA 2013 AND AS 3700-2011.

    GAS:• GAS INSTALLATIONS TO COMPLY WITH AS5601 - 2010

    LIGHTING:• ARTIFICIAL LIGHTING TO COMPLY WITH AS/NZS1680.0 - 2009• ARTIFICIAL LIGHTING TO BE INSTALLED IN ACCORDANCE WITH PART

    3.12.5.5 OF THE BCA 2012• INTERIOR AND WORKPLACE LIGHTING TO COMPLY WITH AS1680.1 - 2006

    MECHANICAL VENTILATION:• MECHANICAL VENTILATION TO COMPLY WITH AS1668.2 2012

    SMOKE DETECTORS:• LOCATION OF SMOKE ALARMS TO BE PROVIDED AND INSTALLED IN

    ACCORDANCE WITH AS3786 - 1993 AMDT 1-4 - 2004 AND PART 3.7.2 OF THE BCA 2012 AND SHALL BE HARDWIRED WITH BATTERY BACKUP.

    ACOUSTICS:• ACOUSTICS TO COMPLY WITH AS1276.1 - 1999

    ROOFING:• SHEET ROOF AND WALL CLADDING - AS 1562.1 - 1992, AS1562.2 - 1992,

    AS1562.3 - 1992• ROOF TILES - AS2049 AMDT 1 - 2002, AS2050 AMDT 1 - 2002• PLIABLE BUILDING MEMBRANES AND UNDERLAYS - AS4200 - 1994• DAMP-PROOF COURSES AND FLASHING - AS2904 - 1995• ROOFING TO BE SELECTED BY CLIENT AND AGREED UPON BY BUILDER

    PLASTIC ROOFING AND WALL CLADDING:• ALL PLASTIC ROOFING AND WALL CLADDING MATERIALS TO COMPLY WITH

    AS4256 - 1994/96

    STORMWATER AND SERVICES:• STORMWATER SHALL COMPLY WITH AS/NZS3500.3 - 2003• STORMWATER SHALL BE TAKEN TO LEGAL POINT OF DISCHARGE TO THE

    SATISFACTION OF THE RELEVANT AUTHORITY• SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITH THE

    RELEVANT AUTHORITIES REQUIREMENTS

    CORROSION:• FOR BUILDINGS IN AREAS LESS THAN 1km FROM BREAKING SURF OR LESS

    THAN 100m FROM SALTWATER NOT SUBJECT TO BREAKING SURF OR IN HEAVY INDUSTRIAL AREAS, WALL TIES SHALL BE EITHER GRADE 316 OR 316L STAINLESS STEEL, OR ENGINEERED POLYMER TIES.

    THRESHOLDS:• IF A THRESHOLD SILL OF THE DOORWAY IS GREATER THAN 190mm ABOVE

    THE FINISHED SURFACE OF THE GROUND TO WHICH THE DOORWAY OPENS, A LANDING SHALL BE PROVIDED NO LESS THAN THE WIDTH OF THE DOOR LEAF, OR 900mm WIDE x 900mm LONG, WHICHEVER IS GREATER.

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A01

    GENERAL NOTESNo. Description Date

  • RO

    BE

    ROBE

    KITCHEN

    LIN

    EN

    GAS

    HEA

    THER

    SH

    ENTRY

    ROBE

    LIVING

    LIVINGCARPET

    CARPET

    BED1CARPETBED2

    CARPET

    BED3CARPET

    TILETILE

    BATHTILE

    L'DRYTILE

    WC

    2600H

    3400H

    2600H 2600H

    2600H2600H

    3400H3400H

    3400HPORCH

    GARAGE

    EX. SHED

    CARPORT

    CONCRETE

    2400H

    TILE

    EXSITNG CONCRETE

    EXISTING GRASS

    EXSITNG BRICK TILE

    EXSITNG BRICK TILE

    SERVICE LANEWAY

    EXISTING G

    ATE

    2638

    1000

    1500

    Obscured Window

    Obscured Window

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A02

    EXISTING GROUND FLOOR PLANNo. Description Date

  • RO

    BE

    ROBE

    KITCHEN

    LIN

    EN

    GAS

    HEA

    THER

    SH

    ENTRY

    ROBE

    LIVING

    LIVINGCARPET

    CARPET

    BED1CARPETBED2

    CARPET

    BED3CARPET

    TILETILE

    BATHTILE

    L'DRYTILE

    WC

    2600H

    3400H

    2600H 2600H

    2600H2600H

    3400H3400H

    3400HPORCH

    GARAGE

    EX. SHED

    CARPORT

    CONCRETE

    2400H

    TILE

    EXSITNG CONCRETE

    EXISTING GRASS

    EXSITNG BRICK TILE

    EXSITNG BRICK TILE

    MIT

    CH

    ELL

    STR

    EET

    SERVICE LANEWAY

    Obscured Window

    Obscured Window

    2638

    1000

    1500

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS IF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS. ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052 A03

    EXISTING SITE PLANNo. Description Date

    1 : 200 @ A3@A1

  • EX. SHED

    EXISTING TILED ROOF STRUCTURESERVICE LANEWAYEXISTING METAL ROOF STRUCTURE

    EXSITING DWELLINGEXISTING GARAGE

    EXISTING METAL ROOF STRUCTURE TO BE REMOVED

    EX. CARPORT

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A04

    EXISTING ROOF PLANNo. Description Date

  • KITCHEN

    ENTRY

    LIVING

    LIVING

    BED1BED2

    BED3 BATHL'DRY

    PORCH

    GARAGE

    SHED

    CARPORT

    PORCH

    FRONT YARD LANDSCAPING & PAVING TO BE RETAINED

    CONCRETE

    2400H

    CARPET

    CARPET

    CARPETCARPET

    CARPET

    TILETILE

    TILETILE

    2600H

    3400H

    2600H 2600H

    2600H2600H

    3400H3400H

    3400H

    CONCRETE

    2400H

    TILE

    EXSITNG CONCRETE

    EXSITNG BRICK TILE PAVING

    EXSITNG BRICK TILE

    GAS

    HEA

    THER

    LIN

    EN

    WC

    REMOVE EXSTING PAVING ANDPLANTER BOXES TO ACCOMODATE FOR PROPOSED WORKS

    SIGNIFIES DEMOLITION

    EXISTING GRASS

    SERVICE LANEWAYREMOVE EXISTING CONCRETE TO MAKE WAY FOR NEW WORKS

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A05

    PROPOSED DEMOLITION PLANNo. Description Date

  • w.

    DN

    15 m²BED 2

    13 m²BED 3

    14 m²Living/Retreat

    15 m²MASTER BED

    7 m²BATH

    5 m²ENS

    ENTRY

    PORCH

    LIVING

    DINING

    3 m²WIP

    TV U

    NIT

    /SH

    ELVE

    S

    KITCHEN

    DECKING

    BBQ

    PROPOSED WALL

    EXISTING WALL

    7 m²WIR

    DES

    K

    DES

    K

    BEN

    CH

    6 m²L'DRY

    RO

    BE

    FIREPLACE

    F

    window seat / storage below

    Overhead cupboards

    Stac

    ker D

    oor (

    2600

    h x

    3770

    w)

    splashback window (700h x 3000w)

    1300

    h x

    2100

    w

    (900h x 2200w)

    (900h x 1900w)

    (2300h x 1440w)

    CU

    PBO

    ARD

    WORK/STUDIO56.3 m2

    8 m²STORAGE/SHED

    OPEN PLAN LIVING 60.2 m2

    SERVICE LANEWAY

    CAR

    SPAC

    E

    3.7m x 1.9m

    3.1m x 1.7m

    1.7m x 3.7m1.9m x 3.7m

    3.6m x 4.1m

    Double Sliding Door

    (1300h x 2600w)

    (170

    0h x

    270

    0w)

    (130

    0h x

    260

    0w)

    (1300h x 2020w)

    RAISE CEILING HEIGHT TO 3.4M TO MATCH EXISTING FRONT OF DWELLING

    3400H

    3400H

    3400H

    3400H

    3400H

    3400H

    3400H

    3400H

    Clothes Line

    Infill wall to match existing wall

    Infill wall to match existing wall

    Tim

    ber G

    ate

    (230

    0h x

    110

    0w)

    (900h x 1650w)

    900h

    x 2

    200w

    Stac

    ker D

    oor 2

    200h

    x 2

    690w

    15 m²BEDROOM 1

    7 m²BATH

    1

    A12

    W101

    W402

    W303

    W404

    W606

    W505

    FD 10

    W909

    W707

    W1210

    W1011

    W1112

    AD 01

    BD 02

    CD 03

    CD 04

    ND 05

    DD 06

    DD 07

    GD 12

    OD 13

    PD 14

    CD 08C

    D 09

    SHEL

    VES

    ED 15 12

    00

    1200

    1000

    2638

    EXISTING G

    ATE

    DESK

    CARSPACE

    2

    A12

    6702

    1202

    2638

    1

    A20

    1000

    1500

    Obscured Window

    Obscured Window

    1750

    DN

    1000

    step

    DN

    150

    mm

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A06

    PROPOSED GROUND FLOOR PLANNo. Description Date

    NOTES:

    - Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 & SHGC-0.61 or approved equivalent.

  • w.

    15 m²BED 2

    13 m²BED 3

    14 m²Living/Retreat

    15 m²MASTER BED

    7 m²BATH

    5 m²ENS

    1200 ENTRY

    PORCH

    LIVING

    DINING

    3 m²WIP

    TV U

    NIT

    /SH

    ELVE

    S

    KITCHEN

    PROPOSED WALL

    EXISTING WALL

    7 m²WIR

    DES

    K

    DES

    K

    BEN

    CH

    6 m²L'DRY

    RO

    BE

    FIREPLACE

    F

    window seat

    Overhead cupboards

    Stac

    ker D

    oor (

    2300

    h x

    3770

    w)

    splashback window (700h x 3000w)

    1300

    h x

    2100

    w

    (900h x 2200w)

    (900h x 1900w)

    (2300h x 1440w)

    8 m²STORAGE/SHED

    OPEN PLAN LIVING 60.2 m2

    3.7m x 1.9m

    3.1m x 1.7m1.7m x 1.3m

    1.7m x 3.7m1.9m x 3.7m

    3.6m x 4.1m

    Double Sliding Door

    (1300h x 2600w)

    (170

    0h x

    270

    0w)

    (130

    0h x

    254

    0w)

    (1300h x 2020w)

    3400H

    3400H

    3400H

    3400H

    3400H3400H

    3400H

    3400H

    Tim

    ber G

    ate

    (230

    0h x

    110

    0w)

    (900h x 1650w)

    900h

    x 2

    200w

    Stac

    ker D

    oor 2

    100h

    x 2

    690w

    15 m²BEDROOM 1

    7 m²BATH

    WORK STUDIO7080 960

    1502870

    240

    Living5670

    90

    L'dry1700

    90

    Bath1900

    1703620 170 4210 240

    240 17620 240

    OVERALL

    OPENINGS

    WALLS

    WALLS

    STU

    DIO

    9480

    240

    BAT H

    3300

    9056

    1024

    0STUDIO

    7080

    490 1650 4940

    240 2000 90 4510 240

    OVE

    RAL

    L

    WAL

    LSOVERALL

    OPENINGS

    WALLS

    790

    2200

    3060

    2690

    740

    OPE

    NIN

    GS

    3000 2656 2200 1565EXISTING

    18100

    2600 4940

    2020 5420

    OVERALL

    OPENINGS

    240

    KITCHEN4880 90

    WIP1290

    90

    ENS3110 160

    MASTER BED4110 90

    RETREAT3800 240 WALLS

    240DINING

    5670 90

    WIR3700 160 4110 90 3800 240 WALLS

    EXIS

    TIN

    G

    9260

    5250

    3770

    Stac

    ker D

    oor 2

    100h

    x 3

    770w

    900h

    x 2

    200w

    240

    240

    2330

    9025

    9090

    OVE

    RAL

    L

    OPE

    NIN

    GS

    WAL

    LS

    WAL

    LS

    240

    ENS

    1700

    90

    WIR

    1930

    90

    CO

    RR

    IDO

    R

    1200

    90

    BAT H

    3680

    240

    OVE

    RAL

    L

    WAL

    LS

    150

    1050

    8

    1728

    150

    5408

    150

    2030 2000 1925 725

    18100

    1139

    9260

    710

    2700

    690

    1100

    720

    2600

    740

    OPE

    NIN

    GS

    CU

    PBO

    ARD

    DESK

    WORK/STUDIO56.3 m2

    EXISTING G

    ATE

    Prop

    osed

    1638

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A07

    PROPOSED DIMENSIONEDGROUND FLOOR PLAN No. Description Date

  • w.

    DN

    15 m²BED 2

    13 m²BED 3

    14 m²Living/Retreat

    15 m²MASTER BED

    7 m²BATH

    5 m²ENS

    1200 ENTRY

    PORCH

    LIVING

    DINING

    3 m²WIP

    TV U

    NIT

    /SH

    ELVE

    S

    KITCHEN

    DECKING 29.7 m2

    7 m²WIR

    DES

    K

    DES

    K

    BEN

    CH

    6 m²L'DRY

    RO

    BE

    BEDROOM1

    FIREPLACE

    F

    window seat

    BATH

    Overhead cupboards

    Stac

    ker W

    indo

    w (2

    300h

    x 3

    770w

    )

    splashback window (700h x 3000w)

    1300

    h x

    2100

    w

    (900h x 2200w)

    (900h x 1650w)

    (2300h x 1440w)

    8 m²STORAGE/SHED

    OPEN PLAN LIVING 60.2 m2

    MIT

    CH

    ELL

    STR

    EET

    SERVICE LANEWAY

    Clothes Line

    Tim

    ber G

    ate

    (900h x 1650w)

    900h

    x 2

    200w

    Stac

    ker D

    oor 2

    100h

    x 2

    690w

    CAR

    SPAC

    E

    1

    A12

    EXISTING G

    ATE

    CU

    PBO

    ARD

    WORK/STUDIO56.3 m2

    DESK

    BBQ

    2

    A12

    1

    A20

    1000

    1000

    1500

    Obscured Window

    Obscured Window

    CARSPACE

    PROPOSED WALL

    EXISTING WALL

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS IF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS. ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052 A08

    PROPOSED SITE PLANNo. Description Date

    1 : 200 @ A3@A1

    NOTES:

    - Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 and SHGC-0.61 or approved equivalent.

  • SERVICE LANEWAY1.

    00°

    PROPOSED GLAZING ROOF STRUCTURE

    EXISTING DWELLING

    PROPOSED TIN SHED

    proposed dp

    proposed dp

    existing dp

    existing dp

    existing dp

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A09

    PROPOSED ROOF PLANNo. Description Date

  • BOU

    ND

    ARY

    BOU

    ND

    ARY

    3400

    C.L

    F.L

    WORK STUDIO EXISTING DWELLINGPROPOSED EXTENSIONPROPOSED DECKING

    PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION

    FD 10

    W505 W3

    03

    3115

    G.C.L

    G.F.L

    N.G.L

    2907 3

    763

    150 DECKING

    BOU

    ND

    ARY

    BOU

    ND

    ARY

    C.L

    F.L

    3400

    EXISTING DWELLING

    PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION

    DECKING

    PROPOSED WORK STUDIO

    W606 W7

    07

    W1112

    G.C.L

    G.F.L150

    3205

    STEPS

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A10

    PROPOSED ELEVATIONSNo. Description Date

    1 Revision 1 Date 1

    EAST ELEVATION

    WEST ELEVATION NOTES:- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 and SHGC-0.61 or approved equivalent.

  • BOU

    ND

    ARY

    BOU

    ND

    ARY

    C.L

    F.L

    3400

    EXISTING DWELLING

    PROPOSED EXTENSION

    PROPOSED DOOR AS PER CLIENTS SELECTION

    PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION

    AD 01 W1

    01

    W402

    BOU

    ND

    ARY

    BOU

    ND

    ARY

    C.L

    F.L

    3400

    SERVING BENCH

    EXISTING DWELLING

    PROPOSED EXTENSION

    PROPOSED RENDER FINISH TO EXTERIOR AS PER CLIENTS SELECTION

    DECKING

    W909

    W1519

    2907

    PROPOSED DECKING

    3

    76

    3

    STEPS

    150

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A11

    PROPOSED ELEVATIONS 2No. Description Date

    1 Revision 1 Date 1

    NORTH ELEVATION

    SOUTH ELEVATIONNOTES:

    - Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 and SHGC-0.61 or approved equivalent.

  • 3400

    BOU

    ND

    ARY

    BOU

    ND

    ARY

    C.L

    EX. F.L

    EXISTING DWELLING

    PROPOSED EXTENSION

    2733

    EXISTING FLOOR

    PROPOSED 100 mm CONCRETE SLAB ON GROUND REFER TO ENGINEERING DETAILS FOR FURTHER DETAILS

    EXISTING

    EXISTING ROOF TO BE TRIMMED

    PROPOSED GLAZED ROOF SYSTEM, REFER TO ENGINEERING FOR FURTHER DETAILS

    PROPOSED FACIA & GUTTER TO MATCH EXISTING

    N.G.L.PROPOSED 600mm DEEP x 350mm WIDE EDGE BEAM, REFER TO ENGINEERING FOR FURTHER DETAILS

    EXISTING FOOTING TO BE CONFIRMED ON SITE, REFER TO ENGINEERING DRAWINGS FOR FURTHER DETAILS

    REFER TO ENGINEERING DRAWINGS FOR BEAM SIZES AND DETAILS

    EXISTING CEILING TO BE RAISED TO MATCH FRONT OF DWELLING

    rais

    ed c

    eilin

    g he

    ight

    3400

    1A13

    2911

    MIN

    .CEI

    LIN

    G H

    EIG

    HT

    2

    40

    0

    Boun

    dary

    Boun

    daryPROPOSED WORK STUDIO

    Garage F.F.LN.G.L N.G.L

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 50

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A12

    PROPOSED SECTIONNo. Description Date

    1 : 501 Section AA

    1 : 50A062 Section BB

  • 2733

    EXISTING CONDITIONS TO BE VERIFIED BY BUILDER ON SITE

    EXISTING DWELLING

    RAISE EXISTING CEILING HEIGHT TO MATCH FRONT OF DWELLING

    EXISTING ROOF

    N.G.L

    PROPOSED 100 mm CONCRETE SLAB ON GROUND REFER TO ENGINEERING DETAILS FOR FURTHER DETAILS

    EXISTING ROOF TO BE TRIMMED

    PROPOSED GLAZED ROOF SYSTEM, REFER TO ENGINEERING FOR FURTHER DETAILS

    PROPOSED FACIA & GUTTER TO MATCH EXISTING

    PROPOSED 600mm DEEP x 350mm WIDE EDGE BEAM, REFER TO ENGINEERING FOR FURTHER DETAILS

    PROPOSED BEAM TO CONNECT WITH EXISTING; REFER TO ENGINEERING DRAWINGS FOR BEAM SIZES AND DETAILS B

    OU

    ND

    ARY

    EXISTING SLAB

    3400

    C.L

    F.L

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 20

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A13

    DETAIL SECTIONNo. Description Date

  • w.

    DN

    15 m²BED 2

    13 m²BED 3

    14 m²Living/Retreat

    15 m²MASTER BED

    7 m²BATH

    5 m²ENS

    ENTRY

    PORCH

    LIVING

    DINING

    3 m²WIP

    TV U

    NIT

    /SH

    ELVE

    S

    KITCHEN

    PROPOSED WALL

    EXISTING WALL

    7 m²WIR

    DES

    K

    DES

    K

    BEN

    CH

    6 m²L'DRY

    RO

    BE

    FIREPLACE

    F

    window seat

    Overhead cupboards

    8 m²STORAGE/SHED

    OPEN PLAN LIVING 60.2 m2

    3400H

    Tim

    ber G

    ate

    15 m²BEDROOM 1

    7 m²BATH

    wind

    ow

    seat

    SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD

    TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTEL

    TVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTV

    TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTEL

    TVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTV

    UPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUP

    RHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRH

    SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD

    Heating wall panelHeating wall panel

    Heating wall panel

    Heating wall panel

    Heating wall panel

    Heating wall panel

    Heating wall panel

    Heat

    ing

    wal

    l pan

    el

    Heat

    ing

    wal

    l pan

    el

    Heat

    ing

    wal

    l pan

    el

    3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1

    USBUSB

    3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1

    USB

    USB

    3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1

    CU

    PBO

    ARD

    WORK/STUDIO56.3 m2

    DESK

    ELECTRICAL KEY:

    LOW VOLTAGE DOWNLIGHTS

    FEATURE PENDANT

    UP LIGHT IN FLOOR OR GARDEN BED

    EXHAUST FAN

    LIGHT SWITCH

    CEILING GPO

    SINGLE GPO

    DOUBLE GPO

    GPO WITHIN O/HEAD CUPBOARDS FOR RANGEHOOD

    LED STRIP

    RECESSED WALL LIGHTS - 50mm AFFL

    ADJUSTABLE DOWNLIGHT

    FLUORESCENT LIGHT

    RECESSED FLUORESCENT FIFFUSER

    CARRIAGE LIGHTS

    3 WAY IXL - LIGHT, FAN AND EXHAUST

    SMOKE DETECTOR (HARD WIRED)

    DATA POINT

    TELEPHONE POINT

    TELEVISION ANTENNA POINT

    ALARM PAD

    ELECTRICAL FLOOR BOX

    CEILING FAN (L) LIGHT COMBINATION

    CHANDALIER - PROVIDE ADDITIONALCEILING SUPPORT

    EXTERNAL WALL MOUNTED LIGHT

    EXTERNAL FLOOD LIGHT NON GLARE

    EXTERNAL FLOOD LIGHT NON GLARE WITH SENSOR

    RECESSED WALL WATER PROOF LIGHT

    GARDEN LIGHT

    BOLLARD LIGHT

    EXHAUST FAN SQUARE

    NOTE:POWERPOINTS WITHIN WET AREAS TO BE INSTALLED TO MINIMUM HEIGHT ABOVE BENCH TO CODE

    PROVIDE NEW CIRCUIT BREAKER BOARDS, WIRING, POWERPOINTS AND LIGHT OUTLETS AS SCHEDULED TO COMPLY WITH RELEVANT AUSTRALIAN STANDARDS. TO BE CARRIED OUT BY A QUALIFIED ELECTRICAIN

    3in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in13in1

    UPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUP

    RHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRHRH

    SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD

    TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTEL

    TVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTV

    UPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUPUP

    SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

    BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB

    exexexexexexexexexexexexexexexexexexexexexexexexexexexexexexexexex

    FBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFBFB

    LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 100

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A14

    PROPOSED ELECTRICAL PLANNo. Description Date

  • W1 / 01 Aluminium Frame - Living / Retreat

    Existing window to be replaced with double glazing window

    W3 / 03 Aluminium Frame - Bedroom 3

    Existing window to be replaced with double glazing window

    W4 / 04 (Master Bed) 02 (Bedroom 2) Aluminium Frame

    Existing window to be replaced with double glazing window

    W5 / 05Aluminium Frame -Bathroom

    W6 / 06Aluminium Frame -Ens

    W8 / 08Aluminium Frame - KitchenOPEN UP WINDOW - As per clients selection

    W9 / 09Aluminium Frame -Living & Dining

    W10 / 11Aluminium Frame -Work Studio

    W11 / 12Aluminium Frame -Work Studio / Bathroom

    W7 / 07Aluminium Frame -Kitchen

    A / D01Feature Entry DoorEntry

    B / D02Solid Double Sliding DoorLiving / Retreat

    C Solid Core Interior DoorHinged D03 - Bedroom 2D04 - Bedroom 3 D05 - Master BedroomD08 - Bath D09 - L'dryD13 - Studio / Bedroom 1 D14 - Studio / Bath

    GSolid Core Interior Door- Sliding D12 - WIP

    E / D15Solid Single Sliding DoorCorridor- Dining & LivingFrosted Glass

    F / D10Glazed Core Interior DoorHingedL'dry

    400

    2100 17

    00

    2700

    800

    1300

    2100

    2020

    800

    1300

    2100

    2600

    1200

    900

    2100

    1900

    1200

    900

    2200

    2100

    875

    700

    1575

    3000

    1300

    900

    2200

    1650

    875

    1725

    2600

    2100 3770

    2600

    2340

    2

    34

    0

    1440 820

    2

    34

    0

    1100 720

    2

    34

    0

    1000

    2

    34

    0

    820

    W12 / 10Aluminium Frame -Work Studio / Bedroom

    900

    1300

    2200

    2200

    820

    2

    34

    0

    DSolid Core Interior DoorSliding D07 - ENSD06 - WIR

    Frosted Glass

    2

    34

    0

    2690

    2200

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 50

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A15

    PROPOSED WINDOW & DOORSCHEDULE No. Description Date

    1 Revision 1 Date 1

    NOTES:- Ceiling insulation plus foil R6.0.- Wall insulation R2.5 plus foil to all existing walls.- Seal gaps, cracks and exhaust fans. - Weather-strip windows and entry doors. - New window frames to double glazed type U-4.5 & SHGC-0.61 or approved equivalent.

  • PROPOSED GLAZING ROOF STRUCTURE

    6060

    3603

    550

    950

    3053

    W15 / 19Aluminum Frame - Proposed Extension areaRefer to manufacturers manual or further details

    W151936

    53

    2828

    1520

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    Asindicated

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A16

    3D VIEW- GLAZINGNo. Description Date

    3D View - GLAZING

    Scale 1:50 - FRONT VIEW Scale 1:50 - SIDE VIEW

    Scale 1:100 - ROOF PLAN

    FOR GLAZING STRUCTURE DESIGN & INSTALLATION; REFER TO MANUFACTURERS MANUAL FOR FURTHER DETAILS

  • ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A17

    3D VIEWS-1No. Description Date

    KITCHEN AREA

  • ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A18

    3D VIEWS-2No. Description Date

    DECKING AREA

  • ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A19

    3D VIEWS-3No. Description Date

    LIVING AREA

    TV & SHELVES

    SHELVES & FEATURE SLIDING DOOR

    FIREPLACE

  • N.G.LN.G.L

    N.G.L

    Min

    .Hei

    ght c

    lear

    ance

    2400

    External Deck F.F.L

    Internal Garage F.F.L

    Natural Ground levelNatural Ground level

    Proposed Work Studio

    Existing Dwelling

    Proposed Outdoor Decking

    Internal Dwelling F.F.L

    G.C.L

    G.F.L

    C.L

    F.F.L

    3400

    150

    ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS AND ENGINEERING DRAWINGS AND DETAILS.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONSIF IN DOUBT ASK, DO NOT GUESS.CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PREPARING SHOP DRAWINGS.ANY DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND APPROVAL IN WRITING.

    PO BOX 271, Nortchote Plaza, Vic, 3070 | [email protected] | (03) 9484 8328

    copyright of C. Kairouz Architects. prior written permission is necessary for reproduction.

    C. KAIROUZ ARCHITECTSDATE:

    SCALE:

    JOB N :o

    AMENDEMENT:PROJECT:

    LOCATION:

    CLIENT:

    No in SET:

    1 : 50

    MITCHELL STREET

    156 MITCHELL STREET, NORTHCOTE

    STACEY & TONY

    02.03.2018

    CKA17-052A20

    DetailNo. Description Date

    1 : 50A061 Section CC

    a0.pdf (p.1)a1.pdf (p.2)a2.pdf (p.3)a3.pdf (p.4)a4.pdf (p.5)a5.pdf (p.6)a6.pdf (p.7)a7.pdf (p.8)a8.pdf (p.9)a9.pdf (p.10)a10.pdf (p.11)a11.pdf (p.12)A12.pdf (p.13)A13.pdf (p.14)A14.pdf (p.15)A15.pdf (p.16)A16.pdf (p.17)A17.pdf (p.18)A18.pdf (p.19)A19.pdf (p.20)A20.pdf (p.21)


Recommended