    AVA

    WIRELESS SECURITY SYSTEM

    INSTALLERS MANUAL

  • 8/2/2019 18020408 AVA Installer ENG RevD

    2/52

    2 Guarantee

    Guarantee

    During the guarantee period the manufacturer shall, at its sole discretion, replace or repair any defectiveproduct when it is returned to the factory. All parts replaced and/or repaired shall be covered for the remainderof the original guarantee, or for ninety (90) days, whichever period is longer. The original purchaser shallimmediately send manufacturer a written notice of the defective parts or workmanship, which written noticemust in all cases be received prior to expiry of the guarantee.

    International Guarantee

    Foreign customers shall enjoy the same guarantee rights as those enjoyed by any customer in Bulgaria, exceptthat manufacturer shall not be liable for any related customs duties, taxes or VAT, which may be payable.

    Guarantee Procedure

    This guarantee will be granted when the appliance in question is returned. The manufacturer shall accept noproduct whatsoever, of which no prior notice has been received.

    Conditions for waiving the guarantee

    This guarantee shall apply to defects in products resulting only from improper materials or workmanship, relatedto its normal use. It shall not cover:

    Damages resulting from transportation and handling; Damages caused by natural calamities, such as fire, floods, storms, earthquakes or lightning; Damages caused by incorrect voltage, accidental breakage or water; beyond the control of the

    manufacturer; Damages caused by unauthorized system incorporation, changes, modifications or surrounding ob-

    jects; Damages caused by peripheral appliances unless such peripheral appliances have been supplied by the

    manufacturer; Defects caused by inappropriate surrounding of installed products;

    Damages caused by failure to use the product for its normal purpose; Damages caused by impropermaintenance;

    Damages resulting from any other cause, bad maintenance or product misuse.In the case of a reasonable number of unsuccessful attempts to repair the product, covered by this guarantee,the manufacturers liability shall be limited to the replacement of the product as the sole compensation forbreach of the guarantee. Under no circumstances shall the manufacturer be liable for any special, accidentalor consequential damages, on the grounds of breach of guarantee, breach of agreement, negligence, or anyother legal notion.

    WaiverThis Guarantee shall contain the entire guarantee and shall be prevailing over any and all other guarantees,explicit or implicit (including any implicit guarantees on behalf of the dealer, or adaptability to specific purposes),and over any other responsibilities or liabilities on behalf of the manufacturer. The manufacturer does neitheragree, nor empower, any person, acting on his ownbehalf, to modify or alter this Guarantee, nor to replaceit with another guarantee, or another liability with regard to this product.

  • 8/2/2019 18020408 AVA Installer ENG RevD

    3/52

    3Contents

    Contents

    Guarantee .......................................................................................... 2

    1. General .......................................................................................... 4 1.1 Main Specifications .......................................................................................... 4

    1.2 Keypad. Principles for Working with the Control Panel Keypad ................... 5

    1.2.1 LED Indication of Control Panel Keypad ....................................................... 61.2.2 Display of the Control Dispay keypad ........................................................... 6

    1.2.3 Sound Indication ............................................................................................ 7

    1.2.4. Built-in Siren .................................................................................................. 7

    1.3 Wireless Keypad ....................................................................................................7

    1.4 Remote Control RC-102TE.....................................................................................7

    2. System Installation.........................................................................8

    2.1 Control Panel Installation ................................................................................. 82.1.1 Location & Mounting .................................................................................. 8

    2.1.2 Initial Activation ........................................................................................ 13

    2.1.3 Installing the Wireless Devices ..................................................................13

    2.2 Device Programming ................................................................................................15

    2.2.1 General Programming Information ......................................................... 15

    2.2.2 General Device Programming ................................................................. 16

    2.2.3 For PIR-Detectors .............................................................................................18

    2.2.4 For Magnetic Contacts ............................................................................. 19

    2.2.5 For Remote Controls ................................................................................ 20

    2.2.6 For Sirens ................................................................................................. 22

    2.2.7 For Fire Detectors .................................................................................... 23

    2.2.8 For Wireless Keypads .............................................................................. 24

    2.2.9 For Wired Detectors ................................................................................. 252.2.10 For Repeater ....................................................................................................26

    2.3 Programming the Functions ......................................................................... 26

    2.4 Users Programming ...................................................................................... 28

    2.5 Programming Detector Areas ....................................................................... 30

    2 6 Output Programming 30

  • 8/2/2019 18020408 AVA Installer ENG RevD

    4/52

    4

    1. General

    1.1 Main Specifications

    AVA is a security system which provides several forms of protection against intruders, fire,technical and medical events.The System consists of a Control Panel with an integrated LCD Display, as well as a keypad forcommunicating with various wireless devices such as: PIR, magnetic contact, remote con-trols, a Wireless Keypad, an Outdoor and Indoor Siren, Repeater. A telephone communicator/dialer for occurring event alerts, as well as a remote control for some of the system functions,can also be installed with the Control Panel.

    1. General

  • 8/2/2019 18020408 AVA Installer ENG RevD

    5/52

    5

    Features:

    - The System is capable of maintaining up to 24 wireless devices. The Detectors can be easilygrouped into 6 security detector Groups. These Groups can be programmed for Entry/Exit,Follow or Instant Alarm activations.- The System maintains 6 Arm functions and 6 Disarm functions and provides an option forprogramming the Groups to be Armed/Disarmed, as well as which of the PGMs to generate asignal. These functions can be activated via the Remote Control or through the 16 user codesfrom Control Panel keypad.- Three types of Panic functions are maintained which can be activated from the Control Panel

    keypad, from the Remote Controls or by telephone.- The System maintains Real Time and records the latest 256 events by date/hour/minute ofoccurrence, which can be reviewed from the Main Module keypad.- A PC software has been designed for the System, which serves to program and monitor /control by the telephone line.- Wireless keypad that can Arm and Disarm and also shows the status of the system.- After reset the system has one Engineer code - 7777, and one Manager code -

    0000.

    1.2 Keypad. Principles for Working with the Control Panel Keypad

    The Control Panel Keypad consists of 20 keys for general and special functions. A short soundsignal is heard when a key is pressed in confirmation that the key has been acknowledged,and also when a given action is terminated a signal is heard to confirm or reject the action.

    1. General

    Keypad

    LCD display

    2

    5

    8

    PRG

    ARM

    BPS

    TRBL

    1 3

    4 6

    7 9

    DISARM

    LED indicationTeleTek AVA24Wed.07/28 13:29

    Button 2

    Button 1

    Button 4

    Button 3

    Button 4

    Button 3

    Button 1

    RC-100TE

  • 8/2/2019 18020408 AVA Installer ENG RevD

    6/52

    6

    Table 1. Buttons description and their action

    1.2.1 LED Indication of Control Panel Keypad

    There are 4 LED indicators for the main events in the system on the LCD keypad display,integrated into the control panel box.

    230V AC lights up in green to indicate main power supply; extinguishes to indicate main

    power supply failure.TROUBLE lights up in yellow in the event of System Tamper; blinks in case of System

    Trouble. It is recommended to call your installer.

    ALARM lights up in red in case of an alarm event; blinks during entry or exit times.

    FIRE lights up in red to indicate a fire event.

    1.2.2 Display of the Control Dispay keypad

    The System Display is 2 16 symbols, using characters and digits with several graphicsymbols for:

    Fire

    1. General

    CLRARM Arming the systemReject entered data or back to the previouslevel in programming modePressing continuously the button will stopthe sound indication of the built-in buzzerfor trouble in the system

    Button Action Button Action

    ENT

    PRG

    BPS

    TRBL

    MEM

    DISARM Disarming the system

    Group bypass

    System troubles review

    Event LOG review

    Acknowledge entered data or forward tothe next level in programming mode

    Scroll to the next menu or letter

    Scroll to the previous menu or letter

    Programming, selecting and deselecting

  • 8/2/2019 18020408 AVA Installer ENG RevD

    7/52

    7

    Armed

    Armed with bypassed detectors

    t Low tempetarure *Bypassed module

    Disallowed module

    Area is ready to Arm

    Open area

    The display has a LED backlight, which can be adjusted for brightness and has an energysaving function while in standby mode and/or during main supply failure.

    1.2.3 Sound Indication

    The following sound indications have been integrated within the AVA:Short beep upon pressing any keyContinuous beep refusal to perform an actionContinuous sound, followed by a chime confirmation signalInterrupted sound signal exit time is running

    Quick interrupted sound signal exit time is running or an important event has occurredsuch as Tamper, Fire, etc.Double sound signal every 20 seconds in the case of technical system problems

    1.2.4. Built-in Siren

    AVA control panel has a built-in dynamic sounder which can be programmed to be activatedaccording to system events and to the duration of the alarm signal duration.

    1.3. Wireless Keypad

    The KBD100TE wireless keypad is used for viewing the status of the system, arming anddesarming the alarm panel The keypad has one input zone that can be used for example for

    1. General

  • 8/2/2019 18020408 AVA Installer ENG RevD

    8/52

    8

    2. System Installation

    2.1 Control Panel Installation

    2.1.1 Location & Mounting

    The location of the AVA panel and its devices has a great effect over the perfor-mance of the wireless system.

    Please take the following recommendations for location and installation of the AVA

    Conrol Panel in order to have best radio signal strength and performance:

    1. The installation site must be free of objects and obstacles that reflects and absorb radiowaves as well as free of interference. Do not install the panel near sources of strong radio (RF)

    fields (computers, neon lights, etc), air conditioners and heaters ducts, circuit breaker boxes, onand close to metal objects - they may cause interference and by this way reduce the systemperformance.

    2. Avoid the installation of AVA control panel in the basement because the range of the systemwill be reduced when the panel is installed below the ground level. If you have to install the panelin the basement install the panel as high as possible.

    3. Select a secure installation site and leave at least 2" around the panel box to permit adequateventilation and heat dissipation.

    4. The installation site should be dry and close to ground connection and telephone line connec-tion/cables.

    5. The installation site should not be a place with drastic temperature changes.

    6. The control panel must be mounted in the center of the installation site in order the distance tothe devices to be equal.

    Before mounting the cabinet, install the four nylon mounting studs into the wall. Recommendeddrill is 6-8 mm (please see at the back of the pack). The screws are not supplied (they dependof the type of the wall). Recommend screws are 4,235 DIN 7981 and wallanchor 630 UN

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    9/52

    Fig. 3 Tamper adjustment

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    10/52

    Fig. 5 Connecting the flat cable and built-in sounder cable

    Connect the flat cable and the built-in sounder cable, as shown in Fig. 5.

    Connect all cables into the cabinet before connecting any external and supply cable to the main

    circuit board.

    The main supply cable entry (for 230V AC 50/60Hz, 0,315mA fuse protection is integrated in thewire terminal) is in the bottom left part of the plastic box. The entry hole is for standard powersupply cable (not supplied). The cable must be tightened with two screws (provided in the nylonbag) and with a plastic cover. The plastic cover is molded in the base of the box. Three of themare provided and are easy to remove. They have two holes for tightening screws (screws are

    10 2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    11/52

    Fig. 6. Connecting the power supply cables

    Install the cable installations for the PGMs and the cables that connects the detectors accord-ing to Fig. 7.

    Antenna

    ! !

    !

    ATTENTIONDo not touchthe antenna

    RESETjumper

    Connector forthe internal LCD

    keyboard

    TAMPER TAMPER

    In 1

    1k 2.2k510510

    In 2

    Zn1 GND

    Scheme of connection of the input Zn1

    Zn2 GNDScheme of connection of the input 2Zn

    2. System installation 11

  • 8/2/2019 18020408 AVA Installer ENG RevD

    12/52

    2. System installation

    The System outputs are of a transistor type (NPN) with a 1k resistor in the collector. Bydefault all these are in NC status i.e. the transistor is ON and the output shuts down towardsthe mass of the eventual external load. PGM1 provides current up to 1 A to GND, where PGMs2, 3 and 4 provide current up to 100 mA to GND. The outputs are intended to be used as opencollectors: i.e. for switching the load over to the mass. The supplementary 1 k resistor in thecollector is used for the positive output level, in case when the Output is designated to bepotential. Thereby the current is limited by the resistor.

    To install the Dailer board in the AVA control panel box see the figure 8 below:

    Fig.8 Connecting the communicator to the AVA main board

  • 8/2/2019 18020408 AVA Installer ENG RevD

    13/52

    132. System installation

    2.1.2 Initial Activation

    An initial activation is performed after the System is installed: i.e. the power is connected (initialpower-up) via a jumper placed for total reset (it is located next to the processor). The Systemwill activate when the monitor displays Please remove reset jumper. After the jumper isremoved, the System will reset in a few seconds (observe Resetting! Please wait on the LCDdisplay of the biult-in keypad) and it will be ready to perform. Now connect the battery cablesThe System is currently with no devices attached to it and its parameters are by default.Tthe following actions have to be performed before the System is installed and ready to work

    after resetting:1. Install and learn the wireless devices, as described in Item 2.1 of this Manual. Perform thedescribed Radio Test.2. Program the devices according to your needs (where these may differ from default set-tings) as described in the Manual in item 2.2. It is recommended the devices to be labeled inorder to facilitate their further use and their log event review.3. Program the Detectors Group according to the required organization and function of theSystem. It would help to assign names to the Groups, according to their functions.4. Program or modify the Arm/Disarm functions, because they are user operated and can beactivated by the Remote Control keys.5. Program the required User Codes and functions which have the right to arm as well as theirattributes.6. Program the outputs if necessary.7. Change system adjustments, where necessary.8. Do not forget to learn the user how to manage the System and when to seek the assistanceof the installer.

    2.1.3 Installing the Wireless Devices

    All wireless devices are installed in one and the same manner.

    Basic Principles

    The System communicates within a unique House Address (HA).

    In order for a given device to be installed in the System, it must not have an HA, which hasbeen acquired from some other AVA System. In such case the deletion must be done. Make itby supplying mains to the device (the battery is first removed and then returned) whilst thedevice tamper remains open: i.e. open the device; if powered, let it stay with no power forabout 10 seconds and then power it up with an open tamper. The red LED will light up

  • 8/2/2019 18020408 AVA Installer ENG RevD

    14/52

    14

    2)Devices

    1)Add Devices

    1)Add Devices

    Start?

    dNxxxx #xxxxxx

    Stop?

    Engineercode

    2

    ENT

    ENT

    ENT to stop procedure

    The Control Panel will display the learned devices, together with their Type (dNxxxx) andUnique number (#xxxxxx) after a procedure has been initiated. Transmission will be initiatedfrom every new device whereby communication reliability during learning and the followingtest mode will be monitored. During the learning mode, the communication of the devices andthe Control Panel uses twice less its nominal power, in order to ensure that as a consequencethe communication between them in any case will be more reliable. It is recommended thatlearning procedure, or at least the radio test, be performed with the Main Module installed at aplace where it would remain permanently, and the device is installed on its permanent operat-ing location.Keep in mind that during installation the first added device, if it is a Detector, belongs to Group1, the second one belongs to Group 2, and every next device belongs to Group 3. Wheninstalled, Fire Detectors shall be attributed to Group 6.Example:

    To the device has been done a reset of its HA and a procedure for adding devices has beenstarted from the Control Panel. Press and release the device tamper. A red LED will indicatetransmission, and a green LED will light up permanently to indicate successful learning. The

    device will then perform a single control transmission using the parameters it has justreceived. If learning fails, press the tamper once again. After the device is learned, it auto-matically passes into Radio Connection Test Mode (communication with reduced output

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    15/52

    15

    After verification that a given device functions properly, its cover must be closed, ensuringthat the tamper is also closed and its installation is thereby finally completed. The Device willautomatically leave the Radio Communication Test Mode in about 6 seconds and will pass intonormal working mode. Test messages will be sent every X minutes to the Control Panel forpermanent monitoring of the radio link availability. The X duration of test messages is the samefor all devices and can be programmed at address 2.2.1 (see below).It is advisable to check if no other devices have been added by mistake during programmingafter they had been learned in the System. This can happen when two or more AVA systemsare working together or close to each other. In such case these should be removed from the

    list of devices (2.2.1).

    ! After a Reset of the main panel or of the House Addresses of the

    devices have been done a learning procedure must be done for everyone of them!

    If the system will be shut off after the devices have been learned to the sys-tem their batteries should be removed in order not to be discharged dur-

    ing the attepmts of the detectors to communicate with the panel!

    2.2 Device Programming

    As a rule programming is not obligatory, because every added device has default programmedparameters which are sufficient for its own normal performance and for that of the System.The default parameters are the provided values or those which have been under-lined in this Manual. In practice it is advisable to program no less than the names of thedevices and the users, for example, if the installer has several preferences.Programming information may be general (referring to all devices) or specific (for instancereferring to PIRs).

    2.2.1 General Programming Information

    There are several types of general information, located in the menu:

    Engineerd

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    16/52

    16

    * TX/RX - by default

    * programming - by default

    Use to make the selection, mark/unmark using PRG and confirm by pressing

    ENT .

    2)Common Prog.

    2)Communication

    ENT

    - here you can set the time for sending test messages from any device (the durationfor repeat) and also the number of repeats to be done.

    Use to make the selection and confirm by pressing ENT .

    1)Communication1min/1s/5times

    ENT

    5min/1s/10times - by default

    10min/2s/5times

    20min/5s/5times

    2.2.2 General Device Programming

    2)Program Device

    2)All Devices

    ENT

    - a screen is displayed, showing the number and the type of the devices, theirunique number and name (by default or whatever has been programmed):

    ENTdNxxxx #

    Device name

    - select a device using the arrows and confirm using ENT , in order

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    17/52

    17

    For ease, the top row shortly displays the available symbols for the digit which is beingpressed.

    For the English language the symbols are:+0-.,:?_ for 0 1@/\()[]* for 1abcABC2 for 2 defDEF3 for 3ghiGHI4 for 4 jklJKL5 for 5mnoMNO6 for 6 pqrsPQRS7 for 7tuvTUV8 for 8 wxyzWXYZ9 for 9

    For the Bulgarian language the symbols are:+0-.,:?_ for 0 1@/\()[]* for 12 for 2 3 for 34 for 4 5 for 5

    6 for 6 7 for 78 for 8 9 for 9

    Device name

    2)Enable/Disable

    ENT

    Device name

    Enabled/Disabled

    ENT

    Use to select an Enable? or Disable? action and confirm by

    pressing ENT .

    Where a device has been disabled, the System can in no way be affected by itsperformance, but it will respond if it receives a message from it.

    Device name

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    18/52

    18

    2.2.3 For PIR-Detectors:

    2)Program Device

    3)PIRs

    ENT

    - a menu appears for viewing the parameters of PIR-detectors only:

    01PIR #

    Device name

    ENT

    - use the arrows to select a PIR-detector and confirm by pressing

    ENT , and then continue with one of the following menus:

    Device name

    1)Sensitivity

    ENT

    1)Sensitivity

    0..7: 3ENT

    - for sensitivity of PIR detector; use the arrows to select sensitivitybetween 00 and 07 (the greater number indicates more sensitive detector) and confirm using

    ENT . Default sensitivity is 3.

    Device name

    2)Device Group

    ENT

    2)Device Group

    N:1

    ENT

    - Addresses a group of detectors. Use arrows to select a group

    between 01 and 06 and confirm by pressing ENT .

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    19/52

    19

    Device name

    5)Remove

    ENT

    approach, as prescribed in item 2.2.1

    Device name

    6)LowTemperature

    ENT

    in this menu the ambient temperature (measured within 1 by any detector) can

    be programmed - if the ambient temperature goes lower than the entered one the Control Panelwill generate and transmit a Low Temperature event (see Communicator Event List). Therewill be only indication on the display by the letter t * but no sound alarm will be generated. Oneof the following temperatures can be selected:

    6)LowTemperature

    0 degree ENT

    -not used-4 degreeC-2 degreeC0 degree C - by default

    +2 degreeC+5 degreeC+15degreeC

    +25degreeC

    2.2.4 For Magnetic Contacts:

    2)Program Device

    4)Magnet. contact

    ENT

    - a menu appears where only MC detectors are reviewed:

    ENT02 #

    Device name

    - use to select a magnetic contact from the list of magnetic contacts,

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    20/52

    20

    1)Impulse Input

    counter: 09

    ENT

    Device name

    2)Group

    ENT

    approach, as prescribed in item 2.2.2.1

    Device name

    3)Change name

    ENT

    approach, as prescribed in item 2.2.2.1

    Device name

    4)Enable/Disable

    ENT

    approach, as prescribed in item 2.2.2.1

    Device name

    5)Remove

    ENT

    approach, as prescribed in item 2.2.2.1

    Device name

    6)LowTemperature

    ENT

    approach, as prescribed in item 2.2.2.1

    2.2.5 For Remote Controls:

    The System can maintain remote controls with up to 4 keys, for each of which a different

    system control function can be programmed. The keys which remain not programmed willexert no effect on the System. The functions can be individually programmed in menu 2.3.

    2)Program Device

    5)Remote Ctrls

    ENT

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    21/52

    21

    1)button 1

    not programmed

    ENT

    Armf-n1 - by default for key 1Armf-n2 - by default for key 3Armf-n3Armf-n4Armf-n5

    Armf-n6DisArmf-n1 - by default for key 2DisArmf-n2 - by default for key 4DisArmf-n3DisArmf-n4DisArmf-n 5DisArmf-n6

    PanicMedical

    Fire CallPoint

    Device name

    2)button 2

    ENT

    - program the function for every individual key the same way as for key 1

    Device name

    3)button 3

    ENT

    - program the function for every individual key the same way as for key 1By default button 3 is not programmed.

    Device name

    5)Change name

    ENT

    approach as prescribed in item 2.2.1

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    22/52

    22

    2.2.6 For Sirens:

    2)Program Device

    6)Siren

    ENT

    - a menu appears where only the sirens, added to the System, are reviewed:

    02SIR #

    Device name

    ENT

    - use to select a siren and confirm using ENT .

    Device name

    1)Audible Events

    ENT

    - use the keys PRG and to select the needed functions of the

    selected siren. The selected event is marked by (*). By default events will not be activated.

    1)Audible Events

    -Alarm

    ENT

    -FIRE

    -Tamper-Panic-Module Lost-Medical-sqwk.on fArm - double sound signal for confirmation of Full Arm

    and triple sound confirmation of Full Disarm-sqwk.on pArm - double sound signal for confirmation of Partial Arm

    and triple sound confirmation of Partial DisarmThe signals emitted by the sirens (if programmed) for Arming and Disarming are 2 and 3

    squawks respectively.

    Device name

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    23/52

    23

    Device name

    3)Change name

    ENT

    approach, as prescribed in item 2.2.1

    Device name

    4)Enable/Disable

    ENT

    approach, as prescribed in item 2.2.1

    Device name

    5)Remove

    ENT

    approach, as prescribed in item 2.2.1

    2.2.7 For Fire Detectors:

    2)Program Device

    7)Fire Detector

    ENT

    - a menu appears for reviewing only Fire Detectors, added to the System:

    02FIR #

    Device name

    ENT

    - use to select a Fire Detector and confirm using ENT .

    Selecting the processing algorithm sensitivity:

    Device name

    1)Sensitivity

    ENT

    1)Sensitivity

    normalENT

    low

    normal - by default

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    24/52

    24

    Device Name

    3)Change name

    ENT

    approach, as prescribed in item 2.2.1

    Device name

    4)Enable/Disable

    ENT

    approach, as prescribed in item 2.2.1

    Device name

    5)Remove

    ENT

    approach, as prescribed in item 2.2.1

    Device name

    6)LowTemperature

    ENT

    in this menu the ambient temperature (measured within 1 by any detector) canbe programmed - if the ambient temperature goes lower than the entered one the Control Panelwill generate and transmit a Low Temperature event (see Communicator Event List). Therewill be only indication on the display by the letter t * but no sound alarm will be generated. Oneof the following temperatures can be selected:

    6)LowTemperature

    0 degree ENT

    -not used

    -4 degreeC-2 degreeC0 degree C - by default

    +2 degreeC

    +5 degreeC+15degreeC+25degreeC

    When the temperature goes higher than the programmed one the LCD display indication disap-pear and a Low Temperature Restore event will be generated by the communicator. If a

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    25/52

    25

    Device name

    3)Change name

    ENT

    approach, as prescribed in item 2.2.2.1

    Device name

    4)Enable/Disable

    ENT

    approach, as prescribed in item 2.2.2.1

    Device name

    5)Remove

    ENT

    approach, as prescribed in item 2.2.2.1

    2.2.9 For Wired Detectors:

    2)Program Device

    9)Wire Devices

    ENT

    9)Wire Device

    1)Add WireDevice

    ENT

    - a menu appears where all System Devices can be reviewed:

    02 #

    Device name

    ENT

    - use to select a vacant device from the list and confirm using ENT .

    Device name

    1)Device Type

    ENT

    1)Device TypeENT

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    26/52

    26

    9)Wire Device

    2)Program W.Dev.

    ENT

    - a menu appears, where the system devices programmed as wired can be re-viewed:

    02WIR #

    Device name

    ENT

    - use to select a vacant device number from the list and confirm usingENT .

    Device name

    1)Device Group

    ENT

    1)Device GroupN: 04

    ENT

    - program the group of detectors to which this wired detector should be attached.Because each of the two wired inputs supports the so called double zoning, it is necessary tospecify which wired detector is interpreted as which detector. Select the wired input num-ber from the following menu, take into consideration that:

    Input 1 detector is wired to terminal Z1 and with 1 k. balancing resistor

    Input 2 detector is wired to terminal Z1 and with 2,2 k. balancing resistorInput 3 detector is wired to terminal Z2 and with 1 k. balancing resistorInput 4 detector is wired to terminal Z2 and with 2,2 k. balancing resistor (see Fig. 7)

    Device name

    2)Wire Input

    ENT

    2)Wire input

    N: 01

    ENT

    - select wired input as described above.

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    27/52

  • 8/2/2019 18020408 AVA Installer ENG RevD

    28/52

    28

    Program which PGM will be assigned to execute the above action

    function N: 013)PGM Number

    ENT

    3)PGM Number

    no PGM selectedENT

    PGM1PGM2PGM3PGM4

    The disarm functions are programmed absolutely analogically to the arming ones.The only difference is that Instant Arm is replaced by Duress event.

    ENT3)Functions

    2)DisARMing

    2)DisARMing

    function N: 01ENT

    - select a number between 1 and 6 and confirm by pressing ENT .

    function N: 01

    1)Group options

    ENT

    - use and PRG to select the range of effect (upon which groups).

    1)Group options

    Group 1ENT

    *Group2*Group3-Group4Group 5

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    29/52

    29

    2.4 Users Programming

    The System maintains 16 user codes with a 16-digit name and parameters and one engineercode with all programming rights, expect the rights to programme user codes and Bypassing.

    Engineer Menu

    4)Codes MenuENT

    ENT4)Codes Menu

    1)User Codes

    Code ****/----

    User name

    ENT

    Use to select the programming code. **** means that the code has programmeddigits, i.e. it is being used, and means it is not being used.

    UseENT

    to confirm the selected program code.

    ENT

    1)Change name

    User name

    ENT

    - editing the name, as described in item 2.2.1

    User name

    2)CodeAttributesENT

    2)CodeAttributes

    Manager ENT

    * Manager - can program other codes* Bypass - bypasses* Log view - reviews Log

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    30/52

    30

    - introduce the new code. Enter it again if it does not duplicate any other existingcode:

    2)ChangeEngineer

    confirm:[****]ENT

    - an error sign will be displayed if the second entry has been incorrectly intro-duced.

    2.5 Programming Detector Areas

    Engineer Menu

    5)GroupENT

    ENTG:01 - group type

    Group name

    - use to select the group to be programmed and confirm by pressingENT .

    Group name

    1)Group TypeENT

    1)Group Type

    InstantENT

    not used

    Instant - by default

    Entry/Exit

    Follow

    - use to select the type and confirm by pressing ENT .

    Group name

    2)Change nameENT

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    31/52

    31

    Engineer menu

    6)OutputsENT

    ENT6)Outputs

    PGM N: 01

    - use to select the PGM output between 1 and 4 and confirm by

    pressing ENT .

    Programming a System Event for Activation

    Use and ENT to select the event and confirm by pressing ENT .

    PGM N: 01

    1)System events

    ENT

    - Alarm- FIRE

    - Tamper

    - Panic

    - Module Lost

    - Medical

    - full Arm

    - part Arm

    PGM N: 01

    2)SystemTroubles

    ENT

    - AC loss

    - Main BATT

    - fuse- module BATT

    - low temp. - In the main AVA control panel versions 4 andlower this System Trouble is named maintenance

    - comm. ERR

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    32/52

    32

    The System outputs are of a transistor type (NPN) with a 1K resistor in the collector. By defaultall these are in an NC state i.e. the transistor is ON and the output shuts down towards the

    mass of the eventual external load. PGM1 has a powerful transistor, whereas PGMs 2, 3 and4 have small power capacities. The outputs are intended to be used as open collectors; i.e.enabled to switch the load over to the mass. The supplementary 1K resistor in the collector isused as a positive output level, in case the Output is designated to be potential. Thereby, theload-carrying capacity is restricted by the resistor.

    2.7 System Adjustments

    Various general System parameters can be programmed in the System Adjustment Menu.

    Engineer Menu

    7)SystemENT

    ENT7)System

    1)LCD settings

    1)LCD settings

    1)Display

    ENT

    Use and PRG to select an event and confirm by pressing ENT

    1)Display* Chime on entry

    ENT

    - a sound is genarated when the entry group is opened

    1)Display

    * display GroupsENT

    - if programmed, the standard type of the main display can be changed:

    TeleTek AVA24

    Wed 07/28 13:29

    ENT

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    33/52

    33

    2)Backlight

    : 3ENT

    - use to adjust the backlight between 0 and 15 and confirm by

    pressing ENT .

    7)System

    2)Main SirenENT

    2)Main Siren

    1)System EventsENT

    - programming the events for which the Control panel activates the siren

    1)System Events

    * Alarm

    ENT

    * Alarm - by default

    * FIRE - by default

    - Tamper

    - Panic

    - Module Lost

    - Medical

    * sqwk.on fArm - double sound signal for confirmation of FullArm and triple sound confirmation of Full Disarm

    * sqwk.on pArm - double sound signal for confirmation of Partial Armand triple sound confirmation of Partial Disar

    Sqwk events are selected by default.

    2)Main Siren

    2)Cut-Off time

    ENT

    Control panel Siren Cut-off time:

    2)Cut-Off time

    2 minuteENT

    2. System installation

    34 S

  • 8/2/2019 18020408 AVA Installer ENG RevD

    34/52

    34

    7)System

    4)Exit TimeENT

    - programming Exit time. This applies to all entry/exit Groups of detectors:

    4)Exit Time

    in seconds: 20ENT

    - from 0 to 255 seconds.

    7)System

    5) fault delayENT

    Main AC 220V power failure will generate an event, which can be delayed in timefrom 0 to 255 min in order to avoid indication of the problem during short power failures:

    5) fault delay

    in minutes: 30

    ENT

    - from 0 to 255 minutes.

    7)System

    6)One-Touch opt.ENT

    Permitting Single button performance. Communicator and Memory messages for

    events, made with short key combinations, are generated for code 16 (where necessaryprogramming needs to be done for code 16). Use and PRG to mark and

    confirm by pressing ENT .

    6)One-Touch opt.

    * one touch menusENT

    - enables access to user menu Arming

    - enabling one touch Arming. Arming rights need to be assigned at code 16

    7)SystemENT

    2. System installation

    352 S t i t ll ti

  • 8/2/2019 18020408 AVA Installer ENG RevD

    35/52

    35

    8)Language

    english

    ENT

    2.8 Dialer

    The dialer can be installed in the plastic box next to the alarm panel board. It has the followingbasic functions:1. Transmits messages by telephone to the control panel for security or telephone.2. Provides computer based remote control and programming.3. Provides hearing out and control cabilities to the control panel by telephone.

    Programming dialer parameters in engineer menu:

    Engineer Menu

    9)DialerENT

    ENT9)Dialer

    1)Phones

    1)Phones

    Phone ENT

    - select a telephone between 1 and 6 using or any of the digits and

    confirm by pressing ENT .

    Phone

    1)Enter PhoneENT

    1)Enter Phone

    ENT

    Assign a telephone number to telephones 1 to 6, for dialing a user or Monitoring Center. Enterdigits from 0 to 9 and/or the letters P, T, D and an interval using the 0 key, where Drepresents a 2 second pause; P changes over to a pulse mode of dialing and T changesover to a tone dialing mode. Dialing begins by default in a tone mode. The interval deletes

    2. System installation

    36 2 System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    36/52

    36

    telephone delivery to that same Destination are terminated. After resetting the dialer, theDestination is 1.

    Phone

    3)Choose Prot.ENT

    3)Choose Prot.

    NoENT

    SIAAdemco

    User

    An exchange protocol SIA or Ademco is selected for every telephone between 1 and6, to work with the Control Panel, or a User protocol for personal call to the user.After dialer reset, the protocol by default is SIA.

    Phone

    4)Enter IDENT

    4)Enter ID

    ENT

    Assign a 4-digit identification number of the site for transmitting events to the Control Panel forevery telephone from 1 to 6. Introduce digits from 0 to 9 or letters from A to F by speed dialing0.After dialer reset, the number by default is 9999.

    ENT9)Dialer

    2)Mess.Filters

    2)Mess.FiltersMessage

    ENT

    - select a message between 01 and 64 and confirm by pressing ENT .

    2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    37/52

    38 2 System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    38/52

    38

    5, 5, 5, 5, 6, 6, 6, 6

    IfDest. Attempt = 1Max.Attempt = 4The following telephone numbers are dialed in succession:3, 4, 1, 2, 5, 6, 3, 4, 1, 2, 5, 6,3, 4, 1, 2, 5, 6, 3, 4, 1, 2, 5, 6,

    A telephone number is dialed only if a number and protocol have been introduced.

    3)Dialer Prop

    3)Line breakENT

    3)Line break

    min(0-99)ENT

    3)Line break serves in case of delay in marking the warning for a disconnected line. Timeis set by minutes. No line disconnection is to be tested if the value is 0. After reset the valueby default is 15 minutes.

    3)Dialer Prop

    4)Common FlagsENT

    4)Common Flags

    - Wait DialtoneENT

    - Call Back

    - Ans Mash

    Dialer Performance Flags

    These can be programmed using and PRG . The flag Wait Dialtone serves

    for awaiting dial signal before dialing the number.If a Call-Back has been marked, UDL is accomplished after the UDL telephone number isdialed from the Control Panel.The Flag Answering Machine is activated during a call. When activated, and if there is a

    2. System installation

    392. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    39/52

    - Sia Hi Speed modem speed of transmission to the Con-trol Panel 300b/sec (if not set 110 b/sec are

    transmitted )- Sia Ext.Area transmitting modifier for area of event- Sia Ext.Time transmitting modifier for time of event- Sia Ext.Date transmitting modifier for date

    There is no marked flag after reset.

    3)Dialer Prop

    6)Hour test

    ENT

    Hour of automatic test transmission to Control Panel:

    6)Hour test

    Hour(0-23)ENT

    Enter a number between 0 and 23. After reset by default it is 12.

    3)Dialer Prop

    7)Minute testENT

    Minute of automatic test transmission to Control Panel:

    7)Minute test

    Min(0-59)ENT

    Enter a number between 0 and 59. After reset by default it is 01.

    ENT9)Dialer

    4)Udl

    4)Udl

    1)Id PanelENT

    1)Id Panel

    ENT

    Enter an identification number of the Control Panel for the UDL. After reset by default it is

    2. System installation

    40 2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    40/52

    3)Callback Ph

    ENT

    Enter a UDL call-back telephone number. Enter digits from 0 to 9 and/or the letters P, T, Dand an interval using the 0 key, where D represents a 2 second pause; P changes to apulse mode of dialing and T changes to a tone dialing mode. Dialing begins in a tone mode. Theinterval deletes unwanted telephone numbers.No introduced numbers will remain on the dialer after a reset.

    4)Udl4)Answer mode

    ENT

    4)Answer mode

    no answerENT

    Modem

    DTMF cntrl

    Use to select the type of signal for answering the telephone line and confirm by

    pressing ENT . Where a modem option has been set after the telephone is answered, the

    System will wait a UDL computer connection. Where a DTMF cntrl option has been set, theSystem will expect human control with the help of DTMF tones, providing for overhearing,speech and control. This procedure is shown on the previous scheme.

    4)Udl

    5)RingsENT

    5)Rings

    count(0-9)ENT

    Assign the number of rings needed for the Control Panel to answer the telephone line. In caseof 0 the telephone will not be answered. After reset by default it is 7.In order to manage the System with DTMF-tones, the Rings parameter must be allowed not tobe 0, and Answer to be DTMF cntrl.Overhear and managing the Control Panel by telephone is done after the number of the Control

    y

    412. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    41/52

    y

    The connection can be terminated by pressing 99 in overhearing. See the diagram below.mode.

    Listening to the AVAs premisesTalking to the AVAs premisesListening and talking to the AVAs premises

    Amplified listening to the AVAs premisesRemote Arming/DisarmingHang up connection

    0 -1 -2 -

    3 -

    99 -*9 -

    Enter 6 digit valid code

    No

    No

    Yes

    Yes

    Switches on respectiveacoustic function

    Press once button or #*

    Wait for signal from AVA system

    42 2. System installation

  • 8/2/2019 18020408 AVA Installer ENG RevD

    42/52

    ENT9)Dialer

    5)Control

    5)Control

    1)Clear bufferENT

    1)Clear buffer

    - to Dest. 1ENT

    - to Dest. 2

    - to Dest. 3

    - to Dest. 4

    Stops telephone line communication by clearing the queue (buffer) of events of addresses to

    those which have been marked. Mark using and PRG .

    5)Control2)Send Test Msg

    ENT

    2)Send Test Msg

    - to Dest. 1ENT

    - to Dest 2

    - to Dest 3

    - to Dest 4

    This sends a test message to the respective destination. These are marked using ,

    PRG and can be sent by pressing ENT .

    5)Manual Control

    3)Pick-UP ENT

    3)Pick-UP

    ModemENT

    433. Maintenance menu

  • 8/2/2019 18020408 AVA Installer ENG RevD

    43/52

    3. Maintenance menu

    The first menu in the Engineer Menu is: 1) Maintenance and it supplements the engineerinstallation. Various system parameters can be checked out here.

    Engineer Menu

    1)MaintenanceENT

    ENT1)Maintenance

    1)SystemTroubles

    - system problems are listed out in 1 2 second intervals (the available ones only)

    1)SystemTroubles

    * lossENT

    * AC loss - the panel does not detect any main powersupply

    * main BATT - main battery trouble* fuse - burnt out auxiliary power supply fuse* module BATT - low battery charge in any of the modules* low temp. - low temperature* comm. ERR - telephone communication trouble* line fault - telephone line trouble

    * RFinterference - currently not maintained

    ENT1)Maintenance

    2)System Events

    2)System Events

    * AlarmENT

    * Alarm* FIRE

    * Tamper

    * Panic

    * Module Lost

    44 3. Maintenance menu

  • 8/2/2019 18020408 AVA Installer ENG RevD

    44/52

    G:--- Group type

    Group name

    ENT

    ENT1)Maintenance

    4)Devices State

    - the status of the Devices is established in sequence for each one in intervals of approxi-

    mately 1 sec. Use to discontinue the automatic mode of display and to review

    them manually.

    dNxxxx #

    Device nameENT

    ENT1)Maintenance

    5)Log

    5)Log

    1)Display LogENT

    1)Display LogENT

    - two screens display the latest 256 events, recorded by the System Memory. The events can

    be reviewed with the help of , and the screens can be switched between by

    pressing PRG .

    For example:

    008 29/07 19:18

    EV_BURG_ALARM

    ENT

    - rated 8thin the event listThe 8thlisted event is a Burglary Alarm event having occurred at 7.18 p.m. on 29 July.

    Additional information will be displayed on the second screen if PRG is pressed.

    453. Maintenance menu

  • 8/2/2019 18020408 AVA Installer ENG RevD

    45/52

    ENT1)Maintenance

    6)Main BATT

    6)Main BATT

    not measured yet

    ENT

    12,5VbattOK10,0VbattLOST11,5VbattLOW

    4. Engineer menus

  • 8/2/2019 18020408 AVA Installer ENG RevD

    46/52

    4. Engineer menus1)Maintenance

    2)Devices

    2)System events

    3)Group state

    4)Devices state

    5)LOG

    1)System troublesSystem troubles

    AC lossmain BATTfusemodule BATTlow temp.comm. ERRline faultRFinterference

    AlarmFIRETamperPanicModule LostMedicalfull Armpart Arm

    System events

    6)Main BATT 12.5 V Normal

    11.5 V Low10.0 V Lost

    ENT ENT

    ENT

    ENT

    ENT

    1)Add devices

    2)Program devices

    ENT

    2)All devices

    3)PIRs

    4)Magnetic contact

    1)Common prog.

    Start?ENT

    ENT

    2)Communication

    1)LED config LED config

    Communication

    ENT ENT

    ENT

    Device: xxENT

    ENT

    1)Change name

    2)Enable/Disable

    3)Remove

    Device PIR: xx

    ENT

    1)Sensitivity

    6)Low temperature

    2)Device group

    3)Change name

    4)Enable/Disable

    5)Remove

    ENT

    Device MC: xx

    ENT

    1)Impulse input

    2)Device Group

    3)Change name

    ENT

    ENT

    ENT

    0..7, 3

    not used-4 degree C-2 degree C0 degree C+2 degree C+5 degree C+15 degree C+15 degree C

    ENT

    5..250, 009

    not used-4 degree C-2 degree C

    4. Engineer menus

  • 8/2/2019 18020408 AVA Installer ENG RevD

    47/52

    From Devices menu

    3)Functions

    6)Siren Device SIR:01..24 1)Audible events

    2)Cut-off time

    3)Change name

    4)Enable/Disable

    5)Remove

    7)Fire detector Device FIR:01..24 1)Sensitivity

    2)Fire group

    3)Change name

    4)Enable/Disable

    5)Remove

    8)Remote KBD

    9)Wire device 1)Add W.Device:01..24

    2)Program W.Dev. 1)Device group

    2)Wire input

    From Remote controls menu

    6)Low temperature

    2)Device group

    3)Change name

    4)Enable/Disable

    5)Remove

    10)Repeater

    ENT ENT

    ENT ENT

    ENT

    ENT

    1)Device type

    ENT

    ENT

    ENT

    1 min.2 min.3 min.4 min.

    AlarmFIRETamperPanicModule LostMedicalsqwk.on fArmsqwk.on pArm

    ENT

    low

    normalhigh

    ENT

    not used-4 degree C-2 degree C0 degree C+2 degree C+5 degree C+15 degree C+15 degree C

    ENT

    wirelesswired

    1)ARMingENT

    Function N:01..06

    ENT

    1)Group options

    2)PGM action

    3)PGM number

    ENTENT

    ENT

    ENT

    Instan ARMGroup 1Group 2Group 3Group 4Group 5Group 6

    no PGM selectedPGM 1PGM 2PGM 3

    no actionSetResetChangepulse 2 sec.pulse 5 sec.pulse 10 sec.

    2)DisARMing Function N:01..06

    ENT

    1)Group options

    2)PGM action

    3)PGM number

    ENTENT

    ENT

    ENT

    no actionSetResetChange

    l 2

    no PGM selectedPGM 1PGM 2

    48 4. Engineer menus

  • 8/2/2019 18020408 AVA Installer ENG RevD

    48/52

    7)System 1)LCD settings

    2)Backlight

    2)Main siren

    3)Entry time

    4)Exit time

    5)AC fault delay

    6)One-touch options

    7)Software version

    8)Language

    8)Service menu

    From Outputs menu

    ENT

    1)Display

    ENT

    Chime on entrydisplay groups

    ENT

    ENT

    0..15, 3

    1)System events

    2)Cut-off time

    ENT ENT

    AlarmFIRETamperPanicModule LostMedicalsqwk.on fArmsqwk.on pArm

    ENT

    1 min.2 min.3 min.4 min.

    ENT

    0..255, 10

    ENT

    0..255, 20

    ENT

    0..255, 30ENT

    one touch menusone touch Arm

    ENT

    english

    9)Dialer 1)Phones Phone N:01..06 1)Enter phone

    2)Choose destination

    3)Choose protocol

    4)Enter ID

    2)Message filters

    3)Dialer properties

    ENTENT ENT

    ENT

    ENT

    Message N:01..64 1)DestinationENT

    ENT

    Dest 01Dest 02Dest 03Dest 04

    ENT

    NoSIAContacIDUser

    Dest. 1Dest. 2Dest. 3Dest. 4

    ENT

    1)Destination attempts

    2)Maximum attempts

    3)Line break

    4)Common flags

    1..9, 2

    ENT

    1..9, 4ENT

    0..99, 15ENT

    ENT

    5)Expand SIA

    6)Hour test

    ENT

    ENT

    1..23, 12

    5. Events LOG 49

  • 8/2/2019 18020408 AVA Installer ENG RevD

    49/52

    5. Events LOG

    NOM EVENT SIA ADEMCO1 2 3 4

    1 EV_ERROR2 EV_BURG_ALARM BA 130 * * * *3 EV_BURG_ALARM_REST BH 130r * *4 EV_FIRE FA 110 * * * *5 EV_FIRE_REST FH 110r * *6 EV_PANIC PA 120 * * * *

    7 EV_PANIC_REST PH 120r * *8 EV_TAMPER TA 137 * * * *9 EV_TAMPER_REST TR 137r * *10 EV_MEDICAL MA 100 * * * *11 EV_MEDICAL_REST MH 100r * *12 EV_SENSOR_BPS UB 570 * *13 EV_SENSOR_BPS_R UU 570r * *14 EV_WATER_ALARM WA 154 * *15 EV_WATER_ALARM_R WH 154r * *

    16 EV_FIRE_BPS FB 571 * *17 EV_FIRE_BPS_REST FU 571r * *18 EV_HEAT_ALARM KA 158 * *19 EV_HEAT_ALARM_R KH 158r * *

    20-21 not used22 EV_FREEZE_ALARM ZA 159 * *23 EV_FREEZE_ALARM_R ZH 159r * *24 EV_DISARM_USER OP 401 * *25 EV_DISARM_REMOTE OQ 407 * *26 not used27 EV_ARM_USER CL 401 * *28 EV_ARM_REMOTE CQ 401 * *

    29-30 not used31 EV_PROG_ENG LB 627 * *32 EV_PROG_ENG_END LX 628 * *33 EV_DURESS HA 121 * * * *34 EV_COMM_LINE YS 351 * *

    35 EV_COMM_LINE_REST YK 351r * *36 EV_COMM_FAIL YC 354 * *37 EV_TEST_AUTO RP 602 * *38 EV_TEST_MANUAL RX 601 * * * *39 EV_FUSE YP 300 * *40 EV FUSE REST YQ 300r * *

    Deault programming bydestinations

    50 6. Electrical specificastions

  • 8/2/2019 18020408 AVA Installer ENG RevD

    50/52

    6. Electrical Specifications

    6.1. GeneralPower supply:

    Primary - 230V AC, 50-60 HzBackup Battery - 12V, from 1,2 to 7 Ah maintenance-free lead-acid

    Current consumption (device operational):

    - from 230V AC, with battery fully charged ~ 40 50 mA- from 230V AC, with 0,8A charge current ~ 100mA

    - from Battery without 230V AC - 40 to 140mA(depends on the backlight mode, output statues, etc)Performance duration in case of C 230V failure - with a 1,2Ah battery

    min. 12 h. max. 30 h- with a 7Ah batterymin. 3 days max. 7 days

    Maximal current at Output 1 (for Uout=CLOSE) - 2AFor Uout=OPEN the output current is restricted by a 1 resistor

    Maximal current at Output 2, 3, 4 (for Uout=CLOSE) - 100 mAFor Uout=OPEN the output current is restricted by a 1 resistorPrimary fuse (230V AC) - 0,315 ABattery fuse (F1) - 2ASupplementary voltage (+12V DC) fuse (F2) - 1AExpected battery life for wireless devices:

    PIR - up to 2 yearsMagnetic contact - up to3 yearsRemote control - up to5 yearsInternal siren - up to1.5 yearsExternal siren - up to4 years

    Fire Detector - up to 3yearsKBD100TE Keypad - up

    to 6 month

    Declaration of conformity 51