7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515 http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 1/30  Huawei DBS3900 Commissioning Procedure Security Level: 2009-05-15 HUAWEI C onfidential Page1, Tota l30 Huawei DBS3900 Commissioning Procedure (V1.2)
Transcript
Page 1: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 1/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page1, Total30

Huawei DBS3900

Commissioning Procedure

(V1.2)

Page 2: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 2/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page2, Total30

Scope

The scope of this document is to give a detail procedure for the commissioning of the

Huawei DBS3900 base station. The document will provide the required tools, contacts

and procedures to be followed.

Document Revision

Version Author Reviewer Date Approver Change Log

Draft S Perkins 02/11/2009 Initial Draft

V1.0 Pan Fei 04/20/2009 V1.0

V1.1 Pan Fei 04/27/2009 V1.1

V1.2 Pan Fei 05/15/2009 V1.2

1. Tools List

Tools Sub Contractor Huawei

Compass X

Digital Camera X

GPS Navigation (Optional) X

Laptop X

Mobile Phone (For

communication)

X

Test Data Card X

Test Mobile Phone and SIM X

USB Flash Memory Stick X

UTP Network Cable X

Vehicle X

Multi meter X

2. Site Awareness

There are a number of site in Canada that are in remote location that requiresituational awareness therefore when travelling to and from remote site locations it is

important that the engineer is equipped for travel to remote sites

Engineers must also be aware that Tower work takes precedent over any other site

work; therefore if tower work is in progress then the tower crew is in control of the site.

Page 3: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 3/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page3, Total30

If required the engineer may have to remain off site until tower crews have finished

any ongoing operations. If tower work is in progress then hard hats are required to be

worn onsite.

3. Commissioning Process

The commissioning process for the Huawei DBS3900 will follow the flow shown below.

The following section will provide a breakdown of the activities required for successful

commissioning of the base station.

Page 4: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 4/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page4, Total30

4. NTP Report

The NTP report is a report that details which sites have received Notice to Proceed! 

(NTP) from the customer. This report then provides the basis for scheduling activities

for commissioning preparation and commissioning activities. From this report a

forecasting schedule will then be produced to initiate the site configuration data to be

prepared and the scheduling of engineers to attend site for commissioning.

The details of this process are not covered in this document and is only included for

informational purposes.

5. Commissioning Preparation

In order for commissioning preparation to be considered complete the following must

have happened.

1. Confirmed NTP report released, hardware installation completed, NodeB was

powered on and IP connectivity is available (Telus)

2. Iub data and cell data for the NodeB is downloaded to RNC (Huawei)

3. Cells were correctly declared on Core Network side (NSN)

4. NodeB was created on OSS (Huawei)

5. IPCLK links were created on 2 IPCLK servers

6. Sub-contractor team got the correct NodeB software and Script from Huawei.

7. Sub-contractor team got the special USB memory stick with LED available and

kept the NodeB software and script with the correct name, file format in the

correct path as following:

NodeB software: \\NodeB\Software\Software.cspBoot 

BootROM: \\NodeB\Software\Firmware.csp 

Data configuration file: \\NodeB\Configuration\NodeBCfg.xml 

Make sure that each USB stick is only kept with 3 files above dedicatedly for one

NodeB, it   s better to label the USB stick with the site Name before commissioning to

avoid the USB sticks mixing if more than 1 site will be integrated for one team. 

Page 5: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 5/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page5, Total30

6. Site Keys and Codes

In order for the engineer to be able to attend a site for commissioning it will be

necessary for the keys and/or codes to be signed out. A valid Huawei ID card will be

required for all engineers attending site.

•  Sign out Telus Mobility key from Huawei Region PM. 

•  Approved footwear must be worn 

•  All employees must have a hard hat, hard hat must be worn at all times

when a tower crew is on site 

7. Site Access Procedures

On attending site the engineer will be required to follow the site access procedures

laid out below.

•  Upon entry into the site one person must immediately call the security control

center and report what site you have entered, provide your name and you are

from Huawei, report site name and site number, report what your work order is

to be on site.

•  The security control center phone number, site name and site ID is posted

on the wall beside the phone

•  If there is a site book you must log into the book.

•  When you are last person in the site you must call security control and sign out

from the site before leaving.

•  You must take care and ensure that the lights are turned off, the shelter door is

locked and properly closed, shut the gate and close the gate lock.

This procedure must happen all the time, every time.

8. Site Installation Checks

Before the engineer begins the commissioning of the base station they will be

required to carry out an audit of the installation quality. There are two parts to the audit,

the first is checklist for the BBU hardware, and the second is the checklist for the

Page 6: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 6/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page6, Total30

DCDU. Please refer to the document: <Telus Checklist for Hardware

Installation.> 

Both checklist need to be completed, photographs must be taken and submitted aspart of the site documentation.

<Site ID>_<Equipment>_Photo.jpg (Overview, DCDU, BBU and Power)

Once the audit checks have been completed and no major issues have been found

then commissioning can commence. If any major issues are found then the issue

must be recorded and escalated to Huawei Regional PM and Huawei RNC Engineer

9. BBU Serial Number After BBU hardware checking, find the BBU serial number as following and record the

number with the file:

<Site ID>_BBU SN_<Serial Number>.txt

For example 21023156401000001572

Page 7: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 7/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page7, Total30

10. Local Commissioning

There are 2 possible ways to commission the Huawei DBS3900, the first is the USB

commissioning method and the second is the LMT Commissioning method, both are

covered below.

10.1 USB Commissioning

Please refer to the document: < DBS3900 Commissioning Key Point

Guide_Telus>

DBS3900 automatically reads the related software and data configuration file under

the fixed directory structure from the USB stick and verifies their names and formats:

NodeBsoftware: \\NodeB\Software\Software.csp 

BootROM: \\NodeB\Software\Firmware.csp 

Data configuration file: \\NodeB\Configuration\NodeBCfg.xml 

Downloading the Software and Data Configuration File

1. Connect the USB Memory stick provided by Huawei to the USB port on the

BBU3900 (do not use the test port). If the USB Memory stick is detected

correctly the following should happen within 20 seconds: the LED on the USB

disk is blinking; the RUN LED on the WMPT is blinking quickly (On for 1s, OFF

for 1s) about 2 seconds, ALM LED on WMPT is ON! since the hardware is

different with the default scripts; CPRI LED on WBBPb are OFF!.

2. Once the downloading of the software and configuration to the DBS3900

begins the following should be occurring: the LED on the USB disk is blinking,

the RUN LED on the WMPT blinks quickly at 4 Hz(0.125s ON, 0.125s OFF)

configuration file, it will last about 15 minutes.

3. The software is automatically activated on the DBS3900 when this happens

the RUN LED on WMPT blinks at 4Hz (ON for 0.125s, OFF for 0.125s) the

RUN LED Blinking (ON

ALM LED

Page 8: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 8/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page8, Total30

USB LED remains solidly ON!. It will take about 10 minutes to activate the

software.

4. The DBS3900 will carry out a reset after the software and the data

configuration has been activated. During this process the LED on the USB will

transition from ON->OFF->Blinking; the RUN LED on WMPT transitions:

ON->OFF->Blinking (ON for 0.125s, OFF for 0.125s); RUN LED on the 2

WBBPb will blink respectively; CPRI LED on WBBPb will flash once RED! 

and then become Green!. The full reset will take about 5 minutes.

5. After the reset is complete, DBS3900 runs normally, the status should now be:

LED on USB is OFF!; RUN LED on WMPT blinks (ON for 1s, OFF for 1s);

 ALM LED on WMPT stays OFF! (If there are no alarms); RUN LED on

WBBPb blinks (ON for 1s, OFF for 1s);CPRI LED on WBBPb stays GREEN! 

Page 9: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 9/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page9, Total30

10.1.1 USB Commissioning Summary

Procedure LED on the USB

disk

RUN LED on the WMPT During

Time

Detecting USB disk ON Blinking (ON for 1s, OFF for 1s) about 2sec

Downloading the

software and the

data configuration

file from the USB

disk

Blinking Blinking (ON for 0.125s, OFF for

0.125s)

about

15min

Activating the

software

ON Blinking (ON for 0.125s, OFF for

0.125s)

about

10min

Resetting NodeB ON->OFF-

>Blinking

ON->OFF->Blinking(ON for 0.125s,

OFF for 0.125s)

about 5min

NodeB Running Software Level

Dependant

Blinking (ON for 1s, OFF for 1s)  " 

10.1.2 USB LED Status dependant on software

Software Level USB LED Status when NodeB is

running

C01B051 OFF

C01B052 OFF

C01B053 ON

Page 10: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 10/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page10, Total30

Note: WMPT always blinks slowly (ON for 1s, OFF for 1s) in 30 seconds, please plug

it again.

Page 11: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 11/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page11, Total30

10.2 Commissioning using LMT

10.2.1 Connecting to the NodeB

1. Connect laptop and NodeB with a Fast Ethernet cable.

2. Set the IP address for laptop. You can log in to the NodeB on the LMT only

when the IP address of the LMT PC is correctly set. For local maintenance on

the LMT, the IP addresses of the LMT PC and the NodeB local maintenance

channel stay within the same network segment. You need set IP Address is

17.21.2.33 and mask is 255.255.0.0 in your laptop.

3. Click the Local maintenance Terminal! in start menu to start LMT.

4. Click the [#] button on the Office row.

Connect

Page 12: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 12/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page12, Total30

5. Click Add and Fill the table. The Office name is NODEB, the IP Address is

17.21.2.15 and the NE type is NodeB then click [Close].

6. Input the User Name: admin Password: NodeB. Click the Login! 

7. Once you are logged in successfully you should see the following.

Page 13: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 13/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page13, Total30

10.2.2 Upgrading the BOOTROM

1. Select the Maintenance tab and choose Service > Software Management.

Then double-click Software Update.

2. The Software Update dialog box is now displayed, select Upgrade BOOTROM

and click [Next].

Page 14: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 14/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page14, Total30

3. The Upgrade BOOTROM dialog box is now displayed, select [Download

BOOTROM Package] and [Activate BOOTROM], then use the [Browse] button

to located the NodeB BOOTROM software on your hard disk. Once this is allcomplete click [Next].

10.2.3 Upgrading the NodeB software

Note: NodeB Bootrom must be upgraded before upgrading NodeB Software; the

reversed procedure may cause the NodeB breakdown.

1. Select the Maintenance tab and choose Service > Software Management.

Then double-click Software Update, as before.

2. The Software Update dialog box is now displayed, this time select Upgrade

NodeB Software and click [Next]

Page 15: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 15/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page15, Total30

3. The Upgrade NodeB software dialog box will not be displayed. Select

[Download NodeB Software Package], [Download By Configuration] and[Activate NodeB Software] and then use the [Browse] button to set the location

of the NodeB Software Package, then click the [Next] button.

After  the upg rade the sof tware is com plete, system wi l l autom at ical ly reset

NodeB, th is wi l l take about 5 m inutes .

Page 16: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 16/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page16, Total30

10.2.4 Upgrading the Configuration File

1. Select the Maintenance tab and choose Service > Software Management.Then double-click Data Config File Transfer. The following dialog box will then

be displayed. Select the [Download (FTP Server to NodeB)] option.

Use the [Browse] button to set the location of the configuration file

(NodeBCfg.xml) and click [Start].

2. Once the progress bar reaches 100% click [Close]. Go to the MML command

window for the NodeB and type the command !  RST NODEB "  . Once the

NodeB has reset the new configuration will take effect. Please wait 5-10

minutes.

10.3 Additional Commissioning Tasks

10.3.1 RUN extra command! sent by Huawei

From LMT, "system#/"Batch Commands#/

Page 17: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 17/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page17, Total30

 Then open the "extra command# file on your hard disk. Excution type is "All# 

and don#t selec t the "prompt when error occurs.

If the some of the commands failed, please call RNC Engineer for

troubleshooting.

To finalize the commissioning of the NodeB and make it ready for call testing it is

necessary to notify the RNC engineer that the software upgrade and the

commissioning is complete. The RNC engineer will need to unlock the cells and load

the appropriate license keys for the NodeB configuration.

11. System Checking

 After the commissioning of the NodeB is complete it is necessary to verify that the

NodeB software and BOOTROM levels are correct and that the configuration file as

loaded correctly in the NodeB. The following section describes the checks required.

11.1 Checking Software and BOOTROM Level

1. Login to the NodeB by LMT.

2. Open a MML Command window and use the following commands to list the

software and BOOTROM version for all units present in the NodeB:

Page 18: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 18/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page18, Total30

LST VER! 

LST SOFTWARE! 

Pleae make sure the version is V200R010C01B053 and then you can make

callp. If it is not the right version, please do Item 10 Local Commissioning

again.

Log the results of the commands to a file and name it<Site

ID>_<SW_Version.txt>. This file will become part of the site

doc umentation package.

11.2 LED Status

 After the activation of the software and the configuration the NodeB should be in a

normal run mode, check the LED status to verify the run state of the NodeB.

LED LED Status Comments

WMPT Run LED Blinking (ON for 1s, OFF

for 1s)

WMPT Alarm

LED

OFF Unless alarms are present

WMPT Act LED ON

WBBPb Run LED Blinking (ON for 1s, OFF

for 1s)

WBBPb Alarm

LED

OFF Unless alarms are present

WBBPb Act ON

CPRI LED ON OFF if not configured, RED is RRU

is not seen

11.3 Local Cell Status

Once the RNC engineer has loaded the appropriate license keys and unlocked the

cells the local engineer can check the cell status using the command DSP LOCELL:;  

log the output to the file <Site ID>_Locell_Status.txt this will form part of the site

documentation to be submitted.

11.4 Cell Configuration

If the local cell is available and operational, check the cell status using the command

DSP CELLCFG: MODE=AL LCELL; log the output to the file <Site ID>_Cell_CFG.txt 

Page 19: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 19/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page19, Total30

this will form part of the site documentation to be submitted. Record the Primary

Scrambling Code for each cell in <Site ID>_CallP_Register.xls for Call_P test.

11.5 RRU Topology

Once finished software upgrade and local commissioning, select Maintenance tab on

LMT, and click RRU Physical Topology, to check the RRU topology if it$s consistent

with what NodeB configured, and snapshot the windows saved as file <Site

ID>_Topology.jpg, this will form part of the site documentation to be submitted.

11.6 Alarm Checks

Once the local cell status has been verified the local engineer will need to check the

alarms on the NodeB and snapshot the alarm window save as fi le <Site

ID>_Alarms.jpg. The engineer will need to resolve or account for any active alarms

on the NodeB with the assistance of the RNC engineers and Huawei technical

support.

11.7 TroubleshootingFor assistance in troubleshooting any problems that arise during the commissioning

of the NodeB the first point of contact will be the RNC engineer for the area. If the

RNC engineer is not able to provide the necessary support the local engineer will

need to contact Huawei technical support.

Page 20: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 20/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page20, Total30

12. Cell Orientation

Prior to call testing it is necessary for the local engineer to verify that there are no

crossed fibers/feeders present in the configuration. To do this the engineer will need

to us a compass to find orientate the direction of the sectors and then verify the Cell

ID and scrambling codes for each antenna. The diagram below details the orientation

of the Antennas, the first sector (Alpha) is the one orientating to the north east, alone

the clockwise, are the second (Beta) and the third (Gamma) sector.

Once the cell orientation has been verified then call testing can begin. ( Telus has

some special sites, which are not defined like this, Huawei will provide a list of these

kind of sites)

13. Call P Testing

13.1 Call-P Procedure

Call P testing is to be carried out with co-ordination with the RNC Engineer; there are

3 sections to the Call P process, which are:

•  Dedicated Call Tests

•  Basic Service Tests

•  Handover Tests

Please call RNC Engineer to check all cells are available. And then ask them to

block 800 Cells, you can make all the 1900 Calls and Handover

Alpha

Gamma

Beta

N

Page 21: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 21/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page21, Total30

After you finish the 1900 call test, please call RNC Engineer to unblock 800 cells

and block 1900 cells, you can make 800 calls and Handover

After you finish the callp, please call RNC Engineer to unblock all cells and tell

them the Callp on site finished.

Record the all of the test results to <Site ID>_Telus_CallP Record after finished

each test.

PS: When you make the PS handover test, please remember to record the

average download speed to "Telus_CallP Record# spreadsheet.

13.2 Dedicated Call Test (For you reference)This section of call testing consists of a number of standard calls that test the routing

of calls between the site and fixed line numbers in both directions (only one of each

call is required per Site). Call tests should consist of the following:

•  Mobile to Fix line using 11 digits (Local Site telephone can be used for this

purpose)

•  Mobile to Fix line using 10 digits (Local Site telephone can be used for this

purpose)

•  Fix line to Mobile using 11 digits (Local Site telephone can be used for this

purpose)

•  Fix line to Mobile using 10 digits (Local Site telephone can be used for this

purpose)

13.3 Basic Service Tests and handover test (For you reference)

This section of call tests deals with testing the services on each cell of the Site, one of

each of the following tests is required in order to achieve a pass grade for the cells

(unless know conditions exist to prevent one or more of the tests, details of these

conditions must be detailed in the Call P documentation).

1. Call RNC Engineer to block all 850 cells. Then make Voice call and video call in

each 1900 cell. Make sure the PSC is right in each cell.

2. Make a call and walk around the site, to make sure there is no call drop. And then

reverse to make sure there is no call drop

Page 22: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 22/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page22, Total30

3. 3. Call RNC Engineer to unblock 850 cells and block all 1900 Cells. Then make

Voice call and video call in each 850 cells. Make sure the PSC is right in each cell.

4. Make a PS download and walk around the site, to make sure there is no call drop.

 And then reverse to make sure there is no call drop

•  Voice call  " to be held for 1 minute and checked for call quality.

•  Video Call  " to be held for 1 minute and checked for video and voice quality.

•  HSPA data test

1. Initiate the internet connection and make sure connection is set up.

2. Login to site http://speedtest.net/ , choose the city where the site

located and initiate the download test and upload test.

3. Check the download speed

4. Check the upload speed

Page 23: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 23/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page23, Total30

13.4 Commissioning Report

Use Batch command tool to collec t the commissioning information and send

back to Huawei.

Steps: 1. Open LMT: System/Batch Commands

2. Click "Open# to find the "Data Scan_20090414_V3.txt# file in the

"Commissioning Report Tool# file.

3. Click " Set# on LMT to set the save direc tion. J ust select "Save

Successful Reaults# and save to your folder.

4. Click "Go# to run the scripts.

Page 24: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 24/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page24, Total30

5. Go to the "Commissioning Report Tool# folder to open the file "ATP

Data Sheet_scripted_V3.xls# . Click "Get Data#, find the batch command result

 just now you saved. And then you can get the values in this XLS file.

6. Save it and send all these three files to Huawei.

14. Compiling and Submitting the Site Documents

14.1 Contents of Site Documentation

There are several documents that form part of the site documentation, all of these

must be provided to Huawei at the completion of the site commissioning and call

testing. The following is a l ist of the information to keep, file convention and purpose

of each document

Item Folder/Naming

Convention

Purpose

NodeB configuration //<Site

ID>/Configuration/NodeBCf 

g.xml

Commissioning Data file provided to

engineer to commission the site.

Site Overview Photo //<Site ID>/Site Photo/<Site

ID>_Overview.jpg

Provides a visual view of the installed

equipment in the rack.

DCDU Audit Checklist //<Site ID>/HW Installation

Check/<Site

ID>_DCDU_Checklist.doc

Confirms the audit results carried out

for the DCDU prior to commissioning of

the site.

DCDU Close Up Photo //<Site ID>/Site Photo/<Site

ID>_DCDU.jpg

Provides a close up view of the

installed DCDUs, to visually confirm

install.

BBU Audit Checklist

BBU Serial Number

//<Site ID>/HW Installation

Check/<Site

ID>_BBU_Checklist.doc

//<Site ID>/HW Installation

Check/<Site ID>_BBU

SN_<Serial Number>.txt

Confirms the audit results carried out

for the BBU prior to commissioning of

the site.

Provide the accurate BBU serial

number for each sites.

Page 25: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 25/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page25, Total30

BBU Close Up Photo //<Site ID>/Site Photo/<Site

ID>_BBU.jpg

Provides a close up view of the

installed BBU, to visually confirm install.

Power Cabling (PSU

end)

//<Site ID>/Site Photo <Site

ID>_PWR.jpg

Provides a close up view of the power

cabling to the PSU.

Site Software

versions

//<Site ID>/Commissioning

Log/<Site

ID>_SW_Version.txt

Provides evidence of current software

and BootROM versions

Local Cell Status //<Site ID>/Commissioning

Log/<Site

ID>_Localcell_Status.txt

Provides evidence of Cell Status after

commissioning.

Cell Configuration //<Site ID>/Commissioning

Log/<Site ID>_

Cells_Config.txt

Provides the cell configuration after the

commissioning of the NodeB

Topology Snapshot //<Site ID>/Commissioning

Log/<Site ID>_Topology.jpg

Provides a topological view of the

NodeB after commissioning

Alarm Snapshot //<Site ID>/Commissioning

Log/<Site ID>_Alarms.jpg

Provides a snapshot of alarms present

on the NodeB after commissioning

Alarm Log //<Site ID>/Commissioning

Log/<Site ID>_Alarms.csv

Provides a log of all of the full alarm

information for the site in CSV format.

Call-p Result //<Site ID>/CallP

Register/<Site

ID>_Telus_CallP Record 

Provides Call-p results of all the cells

for the site.

Commissioning

Report

//<Site ID>_Commissioning

Report

Include three files:  ATP Data

Sheet_scripted_V3.xls,

BatchMML_Result.txt, Data Scan.txt

14.2 Submitting Documentation

Once finished the site commissioning and service test, complete the documents as

requested and keep them in the correct path accordingly as categorized in 14.1:

//<Site ID>/Configuration/

Page 26: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 26/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page26, Total30

//<Site ID>/Site Photo/

//<Site ID>/HW Installation Check/

//<Site ID>/Commissioning Log/

//<Site ID>/Call_P Register/

// <Site ID>Commissioning Report

Each team leader should send out all these request files in 24 hours. after the

commissioning. Please send to Huawei Local PM, Site Technician and RNC

Engineer.

15 Handover Testing Guide

Handover tests are to be carried out under the direction of the RNC engineer as the

RNC engineer will need to monitor and feedback the current serving cells information

to the onsite engineer. Testing will differ slightly between S111 and S222 sites due to

the different in cells present on the site. The general concept of the handover testing

Page 27: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 27/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page27, Total30

is to achieve intra-frequency (and in the case S222 sites inter-frequency) handovers

between adjacent cells on the site.

•  Intra-Frequency HandoverS111:

1. [RNC engineer] Unblock the 3 cells of each sector.

2. [Site Engineer] Make sure mobile phone camp on the cell of sector Alpha,

originate a voice call to the 2nd

 mobile phone.

3. [Site Engineer] Hold on the call proceeding and move to the cell of sector Beta

and Gamma sequently in clockwise, then move to cell of sector Alpha.

4. [Site Engineer] Make sure the voice call is clear and without drop.

5. [Site Engineer] Hold on the call, move back to cell of sector Gamma and Beta

sequently in anti-clockwise, finally back to cell of sector Alpha.6. [Site Engineer] Make sure the voice call is clear and without drop.

7. [Site Engineer] Terminate the call and confirm with RNC engineer for the test

results.

8. [Site Engineer] Record the test results in callp register table.

S222:

1. [RNC engineer] Unblock the 3 cells of F1 (850MHZ) of each sector, block the

other 3 cells of F2 (1900MHZ).

2. [Site Engineer]Follow the step2~8 for S111 handover test.

3. [RNC engineer] Block the 3 cells of F1 (850MHZ) of each sector, unblock the

other 3 cells of F2 (1900MHZ).

step3ste 5

Page 28: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 28/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page28, Total30

4. [Site Engineer]Follow the step2~8 for S111 handover test.

•  Inter-Frequency Handover (only for S222)

1. [RNC engineer] Unblock 850M cell (Alpha), 1900M cell (Beta) and

850M cell (Gamma).

2. [Site Engineer] Make sure mobile phone camp on the 850M cell (Alpha),

originate a voice call to the 2nd mobile phone.

3. [Site engineer] Hold on the call proceeding and move to the 1900M cell (Beta)

in clockwise.

4. [Site Engineer] Make sure the voice call is clear and without drop.

5. [Site Engineer] Confirm with RNC engineer for the successful handover to

1900M cell (Beta) and move to 850M cell (Gamma).

6. [RNC Engineer] Block 850M cell (Alpha), unblock 1900M cell (Alpha).

7. [Site Engineer] Confirm with RNC engineer for the successful handover to

850M cell (Gamma) and move to 1900M cell (Alpha).

8. [RNC Engineer] Block 1900M cell (Beta), unblock 850M cell (Beta).

9. [Site Engineer] Confirm with RNC engineer for the successful handover to

1900M cell (Alpha) and move to 850M cell (Beta).

10. [RNC Engineer] Block 850M cell (Gamma), unblock 1900M cell (Gamma).

11. [Site Engineer] Confirm with RNC engineer for the successful handover to

850M cell (Beta) and move to 1900M cell (Gamma).

12. [RNC Engineer] Block 1900M cell (Alpha), unblock 850M cell (Alpha).

13. [Site Engineer] Confirm with RNC engineer for the successful handover to

1900M cell (Gamma) and move to 850M cell (Alpha).

14. [Site Engineer] Confirm with RNC engineer for the successful handover to

850M cell (Alpha) and move back to1900M cell (Gamma) in anti-clockwise.

15. [Site Engineer] Confirm with RNC engineer for the successful handover to

1900M cell (Gamma) and move to 850M cell (Beta) in anti-clockwise.

16. [RNC Engineer] Block 850M cell (Alpha), unblock 1900M cell (Alpha).

17. [Site Engineer] Confirm with RNC engineer for the successful handover to

850M cell (Beta) and move to 1900M cell (Alpha) in anti-clockwise.

18. [RNC Engineer] Block 1900M cell (Gamma), unblock 850M cell (Gamma).

19. [Site Engineer] Confirm with RNC engineer for the successful handover to

1900M cell (Alpha) and move to 850M cell (Gamma) in anti-clockwise.

20. [RNC Engineer] Block 850M cell (Beta), unblock 1900M cell (Beta).

Page 29: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 29/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page29, Total30

21. [Site Engineer] Confirm with RNC engineer for the successful handover to

850M cell (Gamma) and move to 1900M cell (Beta) in anti-clockwise.

22. [RNC Engineer] Block 1900M cell (Alpha), unblock 85M cell (Alpha).

23. [Site Engineer] Confirm with RNC engineer for the successful handover to

1900M cell (Beta) and move to 850M cell (Alpha) in anti-clockwise.

24. [Site Engineer] Confirm with RNC engineer for the successful handover to

850M cell (Alpha).

25. [Site Engineer] Terminate the call and confirm with RNC engineer for the test

results.

26. [Site Engineer] Record the test results in Callp register table.

Page 30: 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

7/26/2019 19118212-Huawei-DBS3900-Commissioning-MOPV12-20090515

http://slidepdf.com/reader/full/19118212-huawei-dbs3900-commissioning-mopv12-20090515 30/30

 

Huawei DBS3900 Commissioning Procedure Security Level:

2009-05-15 HUAWEI Confidential Page30, Total30