TOPC-E4048E-02
iPASOLINK EX LCT WEB (Draft)
June 2013 Issue (F/W Ver. 1.00.20)
TOPC-E4048E-02 1
LCT COMMUNICATION INTERFACE
iPASOLINK EX WEB LCT
DCN Port supports DHCP default IP Address 172.17.254.253
Communication between the LCT and the EX is via the DCN Port connected by LAN cable
DCN PORT
TOPC-E4048E-02
LCT Startup and Login
Start the browser Internet Explorer and enter the URL http://172.17.254.253/weblct/ to open the WebLCT Login screen.
Enter the “User Name” and “Password” in the provided text boxes and Click Ok button
Default Username : Admin
Password: 12345678
LCT main menu opens in the “Current Status screen”
iPASOLINK EX WEB LCT 2
TOPC-E4048E-02
WebLCT LOGOUT
To Logout of the WebLCT, click on the Logout button on the top right hand of the LCT screen.
When Logout Confirm window appears, Click OK
LCT Login window appears
Close the Browser window to exit WebLCT.
Always Logout using this button before disconnecting the cable.
iPASOLINK EX WEB LCT 3
USER NAMES & PRIVILEGES Category Admin Config User REMOTE
File Operation Up/Down Load Up/Down Load Upload onlySNMP Operation Get/Set Get/Set Get
CURRENT STATUSEQUIPMENT SETUP EQUIPMENT / RADIO CONFIGURATION R/W R/W R
AMR CONFIGURATION R/W R/W R
NETWORK MANAGEMENT SETTINGGENERAL SETTING R/W R R
GENERAL SETTING (DETAIL) R/W R R
ROUTING SETTING R/W R R
IP ACCESS CONTROL SETTING R/W R R
DATE / TIME SETTING R/W R R
USER ACCOUNT / SECURITY SETTING
LOGIN USER LIST R/W R R
USER ACCOUNT MANAGEMENT R/W R R
USER GROUP PROFILE CONFIGURATION R/W R R
SECURITY MANAGEMENT SERVICE STATUS SETTING R/W R R
User: User is able to confirm system configuration and equipment status. It is not available to make any configuration change.
Password :87654321
Default Group: :OPERATOR
Config- Beside of the function can be performed by User, Config user is able to do radio management, base-band management, Switching function management for C-Plane control.
Password: 87654321
Default Group: CONFIG
Admin- Beside of the function can be performed by Config user, Admin user is able to do database management, file management, user management and time management for M-Plane control.
Password: 12345678
Default Group: ADMIN
REMOTE-Functions available When User access Remotely but restricted by the assigned access level
iPASOLINK EX WEB LCT
PROVISIONING
MODEM FUNCTION SETTING
MODEM PORT SETTING R/W R/W R
TX POWER SETTING R/W R/W R
ALM MODE SETTING R/W R/W R
AMR Setting R/W R/W R
ETH FUNCTION SETTING
BRIDGE SETTING R/W R/W R
ETH PORT SETTING R/W R/W R
VLAN SETTING R/W R/W R
FDB SETTING R/W R/W R
ETH OAM SETTING R/W R/W R
MSTP SETTING R/W R/W R
QoS /CLASSIFICATION SETTING R/W R/W R
L2CP TRANSPARENT SETTING R/W R/W R
LLF SETTING R/W R/W R
EQUIPMENT CLOCK / SETTING EQUIPMENT CLOCK SETTING R/W R/W R
ALARM SETTING
CORRELATION SETTING R/W R/W R
ALARM SEVERITY SETTING R/W R/W R
AIS SETTING R/W R/W R
BER THRESH HOLD SETTING R/W R/W R
4
USER NAMES & PRIVILEGES
MAINTENANCEMAINTENANCE CONTROL
LOOPBACK CONTROL MODEM LOOPBACK CONTROL
PROTECTION CONTROLMSTP SW CONTROL R/W R/W R
TIMING SOURCE SW CONTROL R/W R/W R
MODEM MAINTENANCE CONTROL R/W R/W R
H/W_F/W RESET CONTROLH/W RESET CONTROL R/W - -
F/W RESET CONTROL R/W - -
PMON / RMON/ FDB CLEAR R/W ROFFLINE MAINTENANCE R/W R
MAINTENANCE TEST ETH OAM LB/LT/LM/DM CONTROL R/W R R
PMON/RMON REPORTMODEM PMON REPORT R R R
ETH RMON REPORT R R R
VLAN COUNTER REPORT R R R
METERINGCURRENT METERING R R R
EQUIPMENT UITLITYEXPORT (NE->STORAGE) UTILITY R/W R/W -
UPDATE ( STORAGE -> NE ) UTILITY R/W - -
PROGRAM ROM SWITCHING R/W - -
LOG CLEAR FUNCTION R/W R/W -
SHIPMENT R/W - -
INVENTORYEQUIPMENT INVENTORY INFORMATION R R R
SOFTWARE LICENSE INFORMATION R R RSOFTWARE LICENSE SETUP
IMPORT LICENSE KEY R/W
User: User is able to confirm system configuration and equipment status. It is not available to make any configuration change.
Password :87654321
Default Group: :OPERATOR
Config- Beside of the function can be performed by User, Config user is able to do radio management, base-band management, Switching function management for C-Plane control.
Password: 87654321
Default Group: CONFIG
Admin- Beside of the function can be performed by Config user, Admin user is able to do database management, file management, user management and time management for M-Plane control.
Password: 12345678
Default Group: ADMIN
REMOTE-Functions available When User access Remotely but restricted by the assigned access level
iPASOLINK EX WEB LCT
CATEGORY Admin Config User REMOTEPROVISIONING
PMON / RMON THRESHOLD SETTING
PMON THRESHOLD SETTING R/W R/W R
PMON OTHER R/W R/W R
RMON THRESHOLD SETTING R/W R/W R
RMON OTHER R/W R/W R
5
TOPC-E4048E-02
WebLCT Initial Screen
Login User Name
Indicate the current logged in user
Summary Alarm Indication
Indicate the summary alarm of Equipment, TCN, & Maintenance Status
Opposite Site Links
Connect to opposite station
Maintenance
Maintenance ON/OFF button
Logout
Logout button
Menu tree
Indicate the LCT Main Menu
Detail Display
Display detail alarm & status information of items selected from the Tabs
When Log-in, Status window does not collect and show any information for faster startup. Click the Refresh button to view Active Alarms or Tabs for other status information.
iPASOLINK EX WEB LCT 6
TOPC-E4048E-02 7
WebLCT Initial Screen
F/W Version
Indicate the current Firm Ware Version
Site (NE) Name and IP Address
Indicate Network element name and it's IP address (login is Local or Remote)
Opposite Site Links
Show opposite station (s)
Connecting to opposite site
Click on the opposite site links and select the site to connect to. Dropdown List shows the other NEs connected through radio and Back-to-Back connections (inband back to back and NMS back to back). Login screen for selected opposite or Back-to-Back site open in a separate browser window
OR
iPASOLINK EX WEB LCT
TOPC-E4048E-02
Active Alarms & Event Log
Click on the Active Alarm Tab to see details of current Alarms
Click on Save button to save the active alarm list to the PC Click on Event Log tab to see the event Log information. Click save to save the event log to a CSV file
Auto Mode check box allows automatic refreshing of current status. Un check to stop auto refreshing
Event Log is divided in to three categories: Alarm – 1000 events Status – 1000 events Control – 1000 events Last 1000 items of each is stored.
iPASOLINK EX WEB LCT 8
TOPC-E4048E-02
Equipment Detail Alarm and Status
Click on the Equipment and GbE tabs to see the detail alarm and status information
iPASOLINK EX WEB LCT 9
TOPC-E4048E-02 10
Event Log – Filtering
Event Log data can be filtered based on the Severity. Click on the down arrow on the Severity column and select accordingly
Event Log columns can sort according to Ascending or Descending order . Bring the cursor to the column header and Click on the small down arrow select Sort Ascending or Sort Descending
Event Log data can be filtered based on the date. Click on the down arrow on the Date column and select accordingly
To see the Events on a particular date. Select the On check box and select the date from the calendar
To see the Events after or before a particular date. Select the Before or After check box and select the date from the calendar
To see the Events between two dates. Select the Before and After check boxes and select the dates from the calendar
iPASOLINK EX WEB LCT
TOPC-E4048E-02
WebLCT Main MenuMenus for Metering
Equipment UtilityS/W License setup
Can be accessed by selecting the check box “Detail Menu”
Click the “Expand All” icon to expand all menu items and click “ Collapsed All” icon to collapse the menu items
iPASOLINK EX WEB LCT 11
TOPC-E4048E-02
Main Menu
Click the “+” to expand each main menu folder and see the sub-menu items
iPASOLINK - EX-F/W Ver. 1.00.20
NE Branch SettingIn-band Management VLAN settingBridge IP Address setting
iPASOLINK EX WEB LCT 12
TOPC-E4048E-02
Provisioning Menu
Click the “+” to expand each main menu folder and see the sub-menu items
MAC Header Compression
ATPC MAX/Min RangeMTPC TX PowerRX Threshold
iPASOLINK - EX-F/W Ver. 1.00.20
iPASOLINK EX WEB LCT 13
TOPC-E4048E-02
Maintenance Menu
ATPC Manual ControlTX Mute controlCW Control
TX MOD manual control
iPASOLINK - EX-F/W Ver. 1.00.20
iPASOLINK EX WEB LCT 14
TOPC-E4048E-02
EQUIPMENT SETUP
iPASOLINK EX WEB LCT 15
TOPC-E4048E-02
EQUIPMENT CONFIGURATION (1 of 4)
Select the Equipment / Radio Configuration menu from the Equipment Setup Menu. screen opens showing the current equipment / Radio configuration .
Click the Setup icon to configure , modify the Radio configuration, equipment setup wizard opens in Step1. Detailed Equipment / Radio setting screen
iPASOLINK EX WEB LCT 16
TOPC-E4048E-02
Current setting of the Radio Configuration is shown in the left hand side
RADIO CONFIGURATION (2 of 4)
RF Information including Start/Stop frequencies, Frequency step Shift FrequencyTX upper or Lower bandSub Band used
of the EX is shown
Enter the NE Name xx Characters
Select the Channel Spacing (bandwidth)
Show the available Ether bandwidth
Select the TX Power Control Mode. ATPC or MTPC. Parameter setting for each mode is from provisioning menu
Enter the radio signal Frame ID (1 ~ 32)
Enter TX point frequency within the Start and Stop frequency of the RF Information shown.
Select the reference Modulation of the radio signal. It is the modulation used .in non AMR mode
iPASOLINK EX WEB LCT 17
TOPC-E4048E-02
RADIO CONFIGURATION (3 of 4)
Changed parameters are highlighted in blue. Confirm the changes and click the Ok button
In the confirmation window click OK button to continue to AMR Configuration Screen, or select Cancel to finish Radio configuration setting.
iPASOLINK EX WEB LCT 18
TOPC-E4048E-02
RADIO CONFIGURATION (4 of 4 )
Item Parameter DescriptionCurrent setting Current setting of the modem under configurationRF Information Frequency specification of the connected ODUNew Setting Allows setting of the selected modem radio configurationNE NameChannel Spacing 250MHz
50MH/500MHz (future)Specify the radio channel spacing
Reference Modulation
QPSK/16/32/64/[QAM] Specify the reference modulation from the list. In non-AMR mode this is the fixed modulation.In AMR mode TX power is limited to the available TX Power of the reference Modulation
ETH Bandwidth [Mbps] Available Ethernet BW for the selected channel spacing and Reference Modulation is shown
TX RF Frequency xxxxx.xxx [MHz] Enter transmit frequencyRX RF Frequency xxxxx.xxx [MHz] receive frequency
(automatically)Frame ID 1 - 32 Set frame IDTX Power Control MTPC/ATPC Set transmit power control
mode
iPASOLINK EX WEB LCT 19
TOPC-E4048E-02
AMR/Radio Mapping Configuration (1 of 2)
Set the AMR Modulation for Modem 1 & Click Next
Select AMR Operation by clicking the AMR Mode radio button. Select Non Operation radio button not to use the AMR function
Reference Modulation selected in Equipment/Radio Configuration is shown highlighted in green.
Select the other modulations to be used during AMR operation by selecting the appropriate Used radio button
Click the Next button.
Select AMR Configuration from the Equipment Setup menu.. AMR configuration screen shows the current AMR setting.
iPASOLINK EX WEB LCT
Click the Setup Icon. AMR Configuration wizard open in Step1
20
TOPC-E4048E-02
AMR/Radio Mapping Configuration (2 of 2)
Confirm the setting in the Step 2 confirmation screen is correct and click OK. If not click the Back button to go back and change the setting.
iPASOLINK EX WEB LCT 21
TOPC-E4048E-02 22
AMR STATUS
AMR alarm and status can be seen from the Current Status menu, Equipment tab.
Current TX and RX modulation status shows the modulation used..
The AMR Range Mismatch alarm indicate a mismatch between the local side and the opposite side AMR setting.This is due to the AMR range is not the same. (e.g. One side AMR Range is QPSK to 64 QAM, other side 16QAM to 64 QAM.)
Current TX and RX modulation status can also be monitored from the Current Metering screen
iPASOLINK EX WEB LCT
TOPC-E4048E-02
NETWORK MANAGEMENT
iPASOLINK EX WEB LCT 23
TOPC-E4048E-02
GENERAL SETTING
Item Parameter DescriptionIP Address Setting (Bridge 1) (Primary IP address Setting)IP Address x.x.x.x Input IP Address of NMS portSubnet Mask x.x.x.x Input Subnet Mask of NMS portDefault Gateway x.x.x.x Input Default Gateway IP
addressDCN Port SettingDCN Port LCT Port used for LCt connection
NMS Port used for NMS connectionNMS Port SettingConnect NMS Port to NMS
Yes Use NMS Port No Not use NMS Port
Select the General Setting from the Network Management Setting menu..
General setting current setting screen appears.
Click the Setup icon to open the General setting edit window.
This window allows the setting of bridge1 IP address, Subnet Mask and Default Gateway..
Select the radio Button LCT or NMS to Connect LCT or NMS to the DCN Port
Click the OK button to apply the setting
Bridge 1 IP address is the Primary IP address of the NE
iPASOLINK EX WEB LCT
Select the radio Button Yes or No for the Connect NMS port to NMS setting
24
TOPC-E4048E-02 25
GENERAL SETTING (Detail) (1 of 4)
Select the General Setting (Detail) from the Network Management Setting menu..
General Setting (Detail) Screen show the current settings of the detail network parameters.
iPASOLINK EX WEB LCT
TOPC-E4048E-02
GENERAL SETTING (DETAIL) 2 of 4Item Parameter Description
Inband Management VLAN SettingInband Management VLAN usage
Used / Not Used
Select Used or not used for Inband management
VLAN ID 1 ~ 4094 VLAN ID for Inband Management VLAN (default values are set for each stream, overwrite default values)
CoS 1-7 Class of service priority setting for inband VLAN tag sent from the IDU
Ethernet Port Setting DCNPort Mode LCT Select to connect LCT to DCN Port
NMS Select to connect NMS to DCN PortUsage Used Use Ethernet port
Not Used Not use Ethernet portAuto Negotiation Enable enable the Auto Negotiation of Ethernet port
Disable Disable the Auto Negotiation of Ethernet port
LLDP Setting
TX Interval (sec) 5~32767 Interval time for LLDP sending
TX Hold (Times) 2~10 TX Hold Value (TTL=TX Interval*TX Hold+1)
Auto Discovery Setting for DCN and MAIN PortsAuto Discovery LLDP Usage
Used or Not Used
Enable / disable auto search of the NEs through he selected ports
LLDP Mode Standard Enable working with standard LLDP MACProprietary MAC
Enable working with NEC proprietary LLDP MAC. This setting is useful when external layer2 switch (that discard standard LLDP frames,) are used to connect two iPasolink management ports
iPASOLINK EX WEB LCT 26
TOPC-E4048E-02 27
GENERAL SETTING (DETAIL) 3 of 4Item Parameter Description
Radio Bandwidth AdvertisementTX Advertisement Enabled/Disabled Insert radio BW information into LLDP
frameRX Advertisement Enabled/Disabled
NE Branch SettingDefault Gateway x.x.x.x Input the Default Gateway
item
DCN (NMS)portsModem PortInband Management
Appear when inband management is selected as used
Bridge No. bridge number for each of the above ports (1-20)Bridge IP Address IP Address for each BridgeBridge Subnet Mask
Subnet mask for each Bridge
M-Plane Bandwidth LimitationBandwidth Limitation
Enable or Disable Limits the BW used for SV signal over the Radio Frame
Bandwidth (Kbps) 500 to 10000 Kbps Set the BW of the SV signal over the radio
M-Plane PriorityCoS 5,6,7 CoS priority value for the SV signal
over the radioNMS Port Setting
Connect NMS Port to NMS
YES or No Select yes or no for NMS connection to the port
LCT Port SettingRestrict LCT Connection
Any Allow Local & Remote NE LCT accessOnly to Local NE Only Local NE access, Prevent
Remote NE LCT access
iPASOLINK EX WEB LCT
TOPC-E4048E-02
GENERAL SETTING (detail) 4 of 4
Select to which branch NMS port belongs to
Select to which branch Inband Mamagement belongs to
For each branch a bridge number is assigned. Input an IP address and subnet mask for each bridge.
For each port, modem and inband management # (used) listed select a Bridge to be associated
iPASOLINK EX WEB LCT 28
TOPC-E4048E-02
GENERAL SETTING (detail)
For DCN port used in NMS connection to use auto discovery select LLDP used.
iPASOLINK EX WEB LCT
For Main Port# used in in-band connection to use auto discovery select LLDP used.
29
TOPC-E4048E-02
DCN Configuration Example
PNMSj
Port01
VID 4095DCN
30iPASOLINK EX WEB LCT
VID 4095
NE-A192.168.1.78
DCN Port
NE-B192.168.1.79
NE-C192.168.1.80
DCN Port
DCN Port
Port01
TOPC-E4048E-02
Inband Management VLAN 100
Inband DCN Configuration Example
PNMSj
Port01 Port01Port01
• NE-A (192.168.1.78) Port01/MODEM1 Inband DCN
• Inband Management VLAN: 100
• Port01: Trunk Link
• MODEM1: Trunk Link
NE-D192.168.1.81
VID 4095VID 100
VID 4095 is automatically configured by software.
Inband VID
31iPASOLINK EX WEB LCT
Port01
VID 4095
NE-B192.168.1.79
NE-A192.168.1.78
NE-C1192.168.1.80
TOPC-E4048E-02
ROUTING SETTING
iPASOLINK EX WEB LCT 32
TOPC-E4048E-02 33
IP ACCESS CONTROL SETTING – Input Filter List
This function is used as an Access Control List
ADD Input Filter Entry Modify Input Filter Entry
Modify Rule
Delete Entry
iPASOLINK EX WEB LCT
TOPC-E4048E-02 34
IP ACCESS CONTROL SETTING–Forwarding Filter List
ADD Input Filter Entry
iPASOLINK EX WEB LCT
TOPC-E4048E-02 35
DATE / TIME SETTING
Select the Date, and enter the Time. Select the time zone and click the OK button
Select Date/Time Setting from the Equipment Utility Menu
Click the Modify icon to set the date and time
To set the PC time as the EX date / time, select the check box Display PC Time and click the OK button.
iPASOLINK EX WEB LCT
TOPC-E4048E-02
MAINTENANCE CONTROL
iPASOLINK EX WEB LCT 36
TOPC-E4048E-02
LOOPBACK CONTROL
iPASOLINK EX WEB LCT 37
TOPC-E4048E-02
MAINT Control- Modem Loopback Control
If Maintenance mode is selected before applying the maintenance control “ Switch to Maintenance mode first warning message appears
IF loopback cuts the TX output affecting the radio link
Click on Maintenance button on the top of LCT window to enter maintenance mode.
Expand the Maintenance Control from LCT menu。
Expand the Loopback Control from Maintenance Control sub menu.
Select the MODEM Loopback Control from Loopback Control sub menu.
MODEM Loopback Control Window is displayed. Click on Off of the MODEM field of L2 Loopback
Click on the L2 Loopback drop down list and select Loopback1 (near end) or Loopback2 (far end)
Click the OK button to apply the maintenance control of the selected L2 Loopback.
If the Modem L2 Loopback is for the remote NE, then select the Release time
Click OK button to apply the maintenance control. Off indication will turn to Onwith Yellow background
iPASOLINK EX WEB LCT
Modem L2 Loopback provide Ethernet loopback in near end and far end directions. Ethernet frame destination and source MAC addresses will be swapped during the loopback.
38
TOPC-E4048E-02 39
LOOPBACK CONTROL
Event Log shows the control actions for modem L2 loopback
iPASOLINK EX WEB LCT
Highlighting indicate a maintenance control is applied
TOPC-E4048E-02 40
PROTECTION CONTROL
iPASOLINK EX WEB LCT
TOPC-E4048E-02 41
Protection Control- RSTP / MSTP Control
Select MSTP Control under the Maintenance Control, Protection Controlmenu. Protection Control- RSTP Control or MSTP Control screen display current RSTP or MSTP status
Click the MSTP Clear icon, to initialize the MSTP process.
Click the OK button on the warning dialog box to continue the MSTP clear control.
iPASOLINK EX WEB LCT
TOPC-E4048E-02 42
Protection Control- Timing Source SW ControlSelect Timing Source Switch Control under the Maintenance Control, Protection Control menu. Protection Control- Timing Source Switch Control screen display current timing sources selected and switch control status and lockout status.
To manually select a timing source, click on the timing source status under the Timing Source SW controlcolumn of the open the Timing Source Switch control Window
Click on the drop down menu and select Manual SW (if the timing source in normal) or Forced SW (if the timing source is under alarm condition) and select OK.
Select Normal to release the switch control and click OK.
To Lock Out the timing source from being used as a timing source in the equipment, click the Off status under the Lock Out column for the selected Timing source. Timing Source Switch control window for lock out opens.
Select the appropriate radio button ON or OFF and select OK ..
Status of the maintenance control is shown by the yellow background with the switched status
iPASOLINK EX WEB LCT
TOPC-E4048E-02
Modem Maintenance Control-ATPC Manual
•ATPC Manual ControlIf TX Power Control Mode selected is ATPC Mode, it is possible to temporarily disable ATPC mode under maintenance control and transmit a fixed transmit power.
Select ATPC Manual Control On radio button and enter required ATPC Manual power output level within the limits shown.
Click OK button to apply the manual TX control.
This may be required during antenna alignment.
iPASOLINK EX WEB LCT 43
TOPC-E4048E-02
Modem Maintenance CTRL – Mute/CW/Modulation
This maintenance Control switch off the TX output power of the ODU connected to the selected modem
This maintenance Control TX an un-modulated carrier from the selected modem
This maintenance Control select a fixed modulation when the modem is under AMR mode . Select auto to go back to AMR mode starting with QPSK modulation and adjust according to the propagation condition
When TX Mute and CW Control is applied to the NE remotely, it is possible to select an automatic release timer. (these two controls interrupt the radio link) at the end of the timer value the control will be released normalizing the linkCW Function is Not Supported in Remote
iPASOLINK EX WEB LCT 44
TOPC-E4048E-02
H/W _ F/W RESET CONTROL
iPASOLINK EX WEB LCT 45
TOPC-E4048E-02
MAINT Control- H/W Reset Control
Reset control requires the Maintenance Mode to be On
iPASOLINK EX WEB LCT
Select the H/W / F/W Reset Control from the Maintenance Control menu..
H/W Reset Control Screen show the Equipment H/W details
Select the H/W Reset Control
Click the Equipment in H/W Reset Control Screen, to open the Equipment Reset Control window, Click Ok to Rest the . Equipment
46
TOPC-E4048E-02
F/W RESET CONTROL
Reset control applies under Maintenance Mode
iPASOLINK EX WEB LCT
Select the H/W / F/W Reset Control from the Maintenance Control menu..
F/W Reset Control Screen show the F/W information of BB (BaseBand ) section and RF section
Select the F/W Reset Control
Click BB or RF in the F/W reset Control screen to reset the Baseband or RF section Firm Ware.
Click here to go to Program ROM switching screen in the Equipment Utility Menu
47
TOPC-E4048E-02 48
PMON / RMON / FDB CLEARSELECT PMON /RMON /FDB CLEAR FROM THE MAINTENANCE CONTROL MENU
SELECT PMON /RMON CLEAR RADIO BUTTON AND CLICK THE EXECUTE ICON
CLICK THE OK BUTTON TO CLEAR THE PMON / RMON DATA
SELECT FDB TABLE CLEAR RADIO BUTTON AND CLICK THE EXECUTE ICON
iPASOLINK EX WEB LCT
SELECT “ALL” RADIO BUTTON AND CLICK THE OKBUTTON TO CLEAR ALL FDB DATA
SELECT “VLAN ID” RADIO BUTTON AND ENTER THE VLAN ID. CLICK THE OK BUTTON TO CLEAR FDB DATA OF THE SELECTED VLAN.
SELECT “PORT” RADIO BUTTON AND SELECT THE BOARD AND THE PORT FROM THE RESPECTIVE DROP DOWN MENUS. CLICK THE OK BUTTON TO CLEAR FDB DATA OF THE SELECTED PORT.
TOPC-E4048E-02
OFFLINE MAINT CONTROL-
IHG ODU CAN CHANGE THE FREQUENCY SUB BAND BY CHANGING THE TX/RX RF BPF. AFTER CHANGING THE SUBBAND FILTER NEW SUB BAND LETTER USED SHOULD BE SET IN THE ODU USING THIS OFFLINE CONTROL. IF YOU CHANGE THIS PARAMETER WITHOUT CHANGING THE SUB BAND FILTER RADIO LINK MAY FAIL.
SELECT FROM THE DROP DOWN LIST THE SUB BAND LETTER TO BE USED AND CLICK THE SETBUTTON
iPASOLINK EX WEB LCT
F/W ver 1.0017
49
TOPC-E4048E-02
METERING
iPASOLINK EX WEB LCT 50
TOPC-E4048E-02
Metering -
Metering data are refreshed every 10 seconds. To have faster refreshing rate during adjustments, click the Modem and select the High speed (3Sec) radio button.
After the adjustment exit this window by clicking the cancel buttonSelect the Current Metering from the Metering menu. Current metering screen shows:TX Power in dBm RX Level in dBmODU power Supply in voltsBERTX Modulation (Current)RX Modulation (Current)
iPASOLINK EX WEB LCT 51
TOPC-E4048E-02
INVENTORY
iPASOLINK EX WEB LCT 52
TOPC-E4048E-02
INVENTORY - IDU
This MAC Address selected for RSTP Root Bridge
MAC Address of ports required for
Ether OAM
iPASOLINK EX WEB LCT
Select the Equipment Inventory Information from the Inventory menu..
Inventory Information of HardwareFirm WareFPGAModem ParameterFrequencyManagement MAC AddressesUser Port Modem Port MAC Addresses
Click the Export Equipment Inventory Information icon to save the Inventory information.
53
TOPC-E4048E-02
S/W License Information
iPASOLINK EX WEB LCT
Select the S/W License Information from the Inventory menu..
Current S/W License Information status is shown.
Click the Export S/W License Information icon to save the Inventory information.
54
TOPC-E4048E-02
S/W License Setup
iPASOLINK EX WEB LCT
TOPC-E4048E-02
S/W LICENSE SETUP – IMPORT LICENSE KEY
iPASOLINK EX WEB LCT
Select the S/W License Setup menuSelect Import License Key
Current S/W Key information is shown in Import License Key screen
Click the Setup icon to import the License Key
Browse to the location where the License key is and select the file. Click Ok to Import the License file.
Indicate the progress of the License file down load
56
TOPC-E4048E-02
Equipment Utility
iPASOLINK EX WEB LCT 57
TOPC-E4048E-02
Equipment Utility- Export (NE>Storage) Utility
Use this function to export the Equipment Config Data, Network Config Data and User Config Data from NE to storage (Local PC)
Data Type Default File Name
Equipment Configuration Data iPASOLINK-equip.cfg
Network Configuration Data iPASOLINK-network-typeB.cfg
User Configuration Data iPASOLINK-user.cfg
Inventory data Invent_EX_********_YYYMMDD.csv
iPASOLINK EX WEB LCT 58
TOPC-E4048E-02
Program downloadsUse this function to download Program File, FPGA Data and Config Data from storage (Local PC) to update the NE.
iPASOLINK EX WEB LCT 59
TOPC-E4048E-02 60
Program downloadsUse this function to download Program File, FPGA Data and Config Data from storage (Local PC) to update the NE.
iPASOLINK EX WEB LCT
TOPC-E4048E-02 61
Partial Equipment Config DownloadUse this function to download Program File, FPGA Data and Config Data from storage (Local PC) to update the NE.
1 From the Equipment Utility menu select Update (Storage-> NE ) Utility
Put the Equipment to Maintenance mode and select Config Data radio button.
2
Click the Execute button3
In the Update (storage-> NE) utility Config Data window click the select Config data type drop down list arrow. Select Partial Equipment Config
4
Browse to the location where the Equipment config file is located and select the config file. Click the Next button
5
Select the configuration items to upload by selecting from the check boxes. Click OK.
6
iPASOLINK EX WEB LCT
TOPC-E4048E-02
Equipment utility Program ROM Switching
iPasolink uses the program version in the current (foreground) memory bank for its operation. It is possible to have the previous version of the firmware to be in the un-current (back ground) memory bank. To go back to the previous version of the firmware use this function to switch the memory banks.
iPASOLINK EX WEB LCT 62
TOPC-E4048E-02 63
LOG CLEAR FUNCTION
Select Log Clear Function from the Equipment Utility Menu..
Select the Radio button of the Log Type to be cleared, Alarm Log, Status Log, Command Log or All Logs and click the Execute button
Click OK on the confirmation screen. When complete information window opens click OK.
MAINTENACE MODE
1
2
3
Command Log Cleared
iPASOLINK EX WEB LCT
TOPC-E4048E-02
SHIPMENT SettingThis feature allows the clearing of Equipment Configuration, Radio Configuration and the Provisioning items to configure the equipment from the factory default setting
Select Shipment from the Equipment Utility Menu
Click the Shipment icon from the equipment Utility-shipment screen.
Select Provisioning clear from the drop down menu of the shipment control window.
Click Ok . LCT will be disconnected during the Provisioning clear operation.
Login again to configure the IDU after the Provisioning clear.
iPASOLINK EX WEB LCT 64
TOPC-E4048E-02
User Account / Security Setting
iPASOLINK EX WEB LCT 65
TOPC-E4048E-02
LOGIN USER LIST
Click on the User name to modify the logged in user's password or user group.
LOGIN USER LIST menu shows a list of Users logged in to the NE, locally and remotely. “ * “ shows user ID of this user.
Click on the Set Password In User Setting window to change the User Password
To change the User Group click on the Group field and select from the drop down list the group to be changed to.
Following User parameters can be modified:
GroupSecurity LevelPasswordAuth Algorithm and KeyPriv Algorithm and key
iPASOLINK EX WEB LCT 66
TOPC-E4048E-02
USER ACCOUNT / SECURITY SETTING
Item Parameter
User Name 1 t0 31 Characters
Password 8 to 31 Characters
Group Default Groups ADMIN/CONFIG/OPERATOR or Added Groups
Security Level :NoAuthNoPriv
User Login Without authentication and encryption
Security Level :AuthNoPriv
User Login need authentication (MD5 or SHA1 based) but without (Privacy) encryption
Security Level :AuthPriv
User Login need Authentication (MD5 or SHA1 ) and the data is encrypted by DES or AES
Auth Algorithm Select Authentication Algorithm between MD5 or SHA
Auth Key Input 8 to 16 digit Public key of MD5 and SHA1
Priv Algorithm Select the encryption method DES or AES
Priv Key Input 8 to 16 digits Key of DES or AES
MD5 ( Message Digest 5 ) one of the Hash Algorithm for authentication and digital signature. In order to detect the falsification of original data during the data transmission. Original data will be converting the Hash by comparing at both ends
SHA (Secure Hash Algorithm ) one of the Hash Algorithm for authentication and digital signature. In order to detect the falsification of original data during the data transmission. Less than 264 bits of original data will be converting the Hash of 160 bits by comparing at both ends
DES (Data Encryption Standard ) is 56 bit encryption key and encryption by 64 bit block
AES (Advanced Encryption Standard ) SPN structured block encryption, block length is 128 bits and the length of key 128/192/256 bits
iPASOLINK EX WEB LCT 67
TOPC-E4048E-02
USER ACCOUNT MANAGEMENT – Add User
User Account Management function allows adding , Modifying and deleting of User accounts.This function is available for Admin Access level users onlyUp to nine user accounts can be added in addition to the three default user accounts (User, Config & Admin).
Click on the ADD USER icon on the Use Account / Security Settingwindow. Enter the User Name and select the Group from the drop down list of registered user groups.
Click on the Set Auth Key and Set Priv Key icons on the User Settingwindow. Enter the Auth Key and Priv Key for the new user. Click OK
Click on the OK button to register the new user.
Click on the Set Password icon on the User Setting window. Enter the Password for the new user. Click OK
iPASOLINK EX WEB LCT 68
TOPC-E4048E-02
USER ACCOUNT MANAGEMENT Modify/Delete User
MODIFY USER
DELETE USER
Following User parameters can be modified:
GroupSecurity LevelPasswordAuth Algorithm and KeyPriv Algorithm and key
Click the Delete User icon . From the User Setting window select the User Name to be deleted from the drop down list.
Click OK to delete the selected User
Click the User name to be modified.
Click OK to apply the modification to the selected User.
iPASOLINK EX WEB LCT 69
TOPC-E4048E-02
USER GROUP PROFILE CONFIGURATION
PARAMETER DESCRIPTION
Group Name 1 to 32 characters
FTP Allow or Deny using FTP protocol
HTTP Allow or deny using HTTP protocol for WebLCT to access Equipment
SNMP Allow or deny using SNMP protocol to access network equipment
Access Level Specify the User Access Level
In addition to the three default groups (OPERATOR/CONFIG/ ADMIN) Sixadditional groups can be registered.
MODIFY USER GROUP ADD USER GROUP
Click the Delete Group icon . From the Group Setting window select the Group Name to be deleted from the drop down list.
Click OK to delete the selected Group
iPASOLINK EX WEB LCT 70
TOPC-E4048E-02 71
Service Status Setting
iPASOLINK EX WEB LCT
TOPC-E4048E-02
SECURITY MANAGEMENT
Protocol or Service Enabled
Protocol or Service Disabled
iPASOLINK EX WEB LCT 72
TOPC-E4048E-02
SECURITY MANAGEMENT
iPASOLINK EX WEB LCT 73
TOPC-E4048E-02
SNMP and SNMP Community SETTING
Default UDP Port is 161
Item Parameter Description
Community Name Use ASCII within 255 Characters
Set the SNMP community name. Any request with different community name will be refused
Access Level CONFIG- allows only GETADMIN – Allows GET and SET
Assign the access level to the specified server(s)
Access address xxx.xxx.xxx.xxx Specify the valid IP address or network of the SNMP Manager(s)
Subnet Mask 255.xxx.xxx.xxx Subnet Mask of SNMP Manager(s)
Up to 10 SNMP Managers, including PNMSj and MS 5000 can access the iPASOLINK Network
iPASOLINK EX WEB LCT 74
TOPC-E4048E-02
SNMP Trap Entry SETTING
Item Parameter Description
SNMP Version V1 / v2c / v3 Set SNMP version for trap
PDU Type Trap / Inform Set PDU Type for Trap
IP Address 0.0.0.0 Specify the destination IP address of trap
Port 162 (default) (1 t0 65535) Set UDP Port trap
Community name
255 Character Set communication name of the trap. This must match on both SNMP server and agent
Security Level NoAuthNoPriv/ AuthNoPriv/AuthPriv
SNMP Engine ID
Auth Algorithm MD5 or SHA
Auth Key 8 to 16
Priv Algorithm DSE or AES
Priv Key 8 to 16
This setting applies to the additional SNMP managers not to PNMSj or MS5000
iPASOLINK EX WEB LCT 75
TOPC-E4048E-02
NTP SETTING
iPASOLINK EX WEB LCT 76
TOPC-E4048E-02
FTP and HTTP setting
Item Parameter Description
FTP Enable (Running)Disable (Stopped)
Start and Stop FTP service
TCP Port (Command)
21(default Set TCP port of FTP server (for received command) ) (1 to 65535)
TCP Port (Data) 20 (Default) Set the TCP port of FTP server (for data transmit) (1 to 65535)
Max session 3 Maximum user connection
Auto Stop Enable Enable FTP server break the connection in 90 sec automatically after no operation on the client
Disable Disable FTP server break automatically
Item Parameter Description
HTTP Enable (Running)Disable (Stopped)
Start and Stop HTTP service
TCP Port 80(default) Set the port number of HTTP server (1 to 65535)
iPASOLINK EX WEB LCT 77
TOPC-E4048E-02
PMON/RMON Report
iPASOLINK EX WEB LCT 78
TOPC-E4048E-02
MODEM PMON REPORT
iPASOLINK EX WEB LCT 79
TOPC-E4048E-02 80
MODEM PMON REPORT
iPASOLINK EX WEB LCT
TOPC-E4048E-02
ETH RMON REPORT
iPASOLINK EX WEB LCT 81
TOPC-E4048E-02
ETH RMON REPORT
iPASOLINK EX WEB LCT 82
TOPC-E4048E-02
VLAN COUNTER REPORT
iPASOLINK EX WEB LCT 83