6
CEILING PLAN VIEW SCALE 1 / 50 INSTALLATION DETAIL SCALE 1 / 10 INSTALLATION DETAIL SH-0016-1 BILL OF MATERIALS DESCRIPTION STOCK NUMBER QTY ITEM Angle Molding 7800 16 1 12' ID/HD Suprafine Main Beam 7500/7501 76 2 2' Suprafine Cross Tee XL7520 180 3 Suprafine 60 Deg. Cross Tee - 48in MBS XM756048 160 4 Suprafine Perimeter Cross Tee - 48in MBS XM7548 40 5 Suprafine 60 Deg. Right Corner Bracket 75CB60R 342 6 2" Beam End Retaining Clip BERC2 38 7 Cross Tee Adapter Clip XTAC 38 8 Perimeter Angle Clip PAC 76 9 Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Right Rt. Triangle 100007 400 10 12 Gauge Hanger Wire (Qty. = number of min. hanging point locations) 7891 209 11 These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and regulations (Legal Requirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. Armstrong is not licensed to provide professional architecture or engineering design services. DATE: 10/2/2018 PD DRAWN BY: NJF DESIGNFLEX SH-0016-1 481.000 ( 40' 1" ) 462.000 ( 38' 6" ) EXAMPLE LAYOUT AND BOM SHOWN WITH LYRA PANELS AND SUPRAFINE SUSPENSION SYSTEM PANEL PRODUCT FAMILIES COMPATIBLE WITH THIS LAYOUT: LYRA, CALLA, OPTIMA, AND ULTIMA SUSPENSION SYSTEMS COMPATABLE WITH THIS LAYOUT: SUPRAFINE ID/HD NOTES: THE EXAMPLE LAYOUT AND CORRESPONDING BOM SHOWN ARE MEANT TO BE USED AS REFERENCE POINTS WHEN SPECIFYING A DESIGNFLEX SYSTEM. IF YOU PLAN TO USE THE EXACT LAYOUT SHOWN, OR ANY VARIATION THEREOF, CONSIDER THE FOLLOWING NOTES: 1) DRAWING DETAILS SHOW A CEILING PLAN VIEW WHICH IS FROM A PLENUM POSITION LOOKING DOWN ONTO THE BACKSIDE OF THE CEILING SYSTEM. BOM LISTS DESCRIPTIONS THAT COORDINATE WITH THE DATA PAGES, AND THESE ITEM DESCRIPTIONS ARE BASED ON VIEWING THE FACE OF THE PRODUCTS. 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED AT STANDARD 6" OC ROUTE HOLE INCREMENTS ALONG THE MAIN BEAMS - ALL MAIN BEAMS ARE INSTALLED WITH ALIGNED ROUTE HOLES. 3) ANGLE BRACKETS USED WITHIN LAYOUTS HAVE SCREWS, WASHERS, AND NUTS INCLUDED WITH THEM FOR FASTENING TO MAIN BEAMS. IF CORNER BRACKETS ARE USED IN THE SYSTEM THEY WILL REQUIRE SCREWS THAT ARE NOT INCLUDED AND NEED TO BE SUPPLIED BY OTHERS. 4) SCREWS, RIVETS, AND OTHER GENERAL FASTENERS THAT ARE NOT INCLUDED IN BOM OR IN DETAILS BELOW, NEED TO BE SUPPLIED BY OTHERS. REFER TO INSTALLATION INSTRUCTIONS FOR DETAILS ON REQUIRED FASTENERS. 5) HANGER WIRE LOCATIONS SHOWN BELOW ARE ONLY SUGGESTIONS BASED ON EXAMPLE LAYOUT AND CAN BE MOVED IN ACCORDANCE WITH FOLLOWING REQUIREMENT - HANGER WIRES ARE REQUIRED ALONG MAINS WITHIN 24" OF THE WALL AND NO MORE THAN 48" O.C THEREAFTER. 6) CONDITIONS SHOWN ARE FOR NON-SEISMIC INSTALLATIONS (SEISMIC DESIGN CATEGORY A,B) - REFERENCE INSTALLATION INSTRUCTIONS FOR CONSIDERATIONS AND REQUIREMENTS FOR SEISMIC INSTALLATIONS. 7) DETAILS BELOW AND BOM ARE SUBJECT TO CHANGES AT THE PERIMETER BASED ON THE LAYOUT (LINEAR FEET OF PERIMETER, FULL SIZE VS. CUT PANELS, BORDER PANEL INSTALLATION METHOD). 8) 7800 WALL ANGLE PERIMETER SHOWN BELOW. REFERENCE INSTALLATION INSTRUCTIONS FOR DETAILS ON ALTERNATIVE PERIMETER SOLUTIONS. 9) BOM DOES NOT ACCOUNT FOR THE USE OF SCRAP OR EXCESS MATERIAL CUT FROM OTHER ITEMS. 10) REFER TO MASTER PARTS SHEET, PANEL SHEET, AND INSTALLATION INSTRUCTIONS ILLUSTRATIONS SHEET FOR SPECIFIC DETAIL VIEWS AND DIAGRAMS OF ALL PARTS AND PIECES LISTED IN BOM. SIDE A - REPRESENTS A BORDER CONDITION UTILIZING A SINGLE GRID MEMBER CONNECTION TO THE PERIMETER SIDE B - REPRESENTS A BORDER CONDITION UTILIZING A SINGLE GRID MEMBER CONNECTION OR MULTIPLE GRID MEMBER CONNECTIONS TO THE PERIMETER REFERENCE INSTALLATION INSTRUCTIONS FOR FURTHER DETAILS ON HOW THESE BORDER CONDITIONS ARE INSTALLED 48.594 48.000 15.000 24.000 MAIN BEAMS O.C 48.000 HANGER WIRE O.C 24.000 HANGER WIRE O.C 1 2 9 8 5 3 6 4 7 10 11 PERIMETER CUT PANELS AND CROSS TEES SIDE A SIDE B
Transcript
Page 1: 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED … · 3) angle brackets used within layouts have screws, washers, and nuts included with them for fastening to main beams. if

CEILING PLAN VIEW

SCALE 1 / 50

INSTALLATION DETAIL

SCALE 1 / 10

INSTALLATION DETAIL

SH-0016-1 BILL OF MATERIALS

DESCRIPTIONSTOCK NUMBERQTYITEM

Angle Molding7800161

12' ID/HD Suprafine Main Beam7500/7501762

2' Suprafine Cross TeeXL75201803

Suprafine 60 Deg. Cross Tee - 48in MBSXM7560481604

Suprafine Perimeter Cross Tee - 48in MBSXM7548405

Suprafine 60 Deg. Right Corner Bracket75CB60R3426

2" Beam End Retaining ClipBERC2387

Cross Tee Adapter ClipXTAC388

Perimeter Angle ClipPAC769

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Right Rt. Triangle10000740010

12 Gauge Hanger Wire (Qty. = number of min. hanging point locations)789120911

These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and

regulations (Legal Requirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user

is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. Armstrong is not licensed to provide professional architecture or engineering design services.

DATE: 10/2/2018PDDRAWN BY: NJF

DESIGNFLEX SH-0016-1

481.000(

40' 1"

)

462.000(

38' 6"

)

EXAMPLE LAYOUT AND BOM SHOWN WITH LYRA PANELS AND SUPRAFINE SUSPENSION SYSTEM PANEL PRODUCT FAMILIES COMPATIBLE WITH THIS LAYOUT: LYRA, CALLA, OPTIMA, AND ULTIMA SUSPENSION SYSTEMS COMPATABLE WITH THIS LAYOUT: SUPRAFINE ID/HD

NOTES:THE EXAMPLE LAYOUT AND CORRESPONDING BOM SHOWN ARE MEANT TO BE USED AS REFERENCE POINTS WHEN SPECIFYING A DESIGNFLEX SYSTEM. IF YOU PLAN TO USE THE EXACT LAYOUT SHOWN, OR ANY VARIATION THEREOF, CONSIDER THE FOLLOWING NOTES: 1) DRAWING DETAILS SHOW A CEILING PLAN VIEW WHICH IS FROM A PLENUM POSITION LOOKING DOWN ONTO THE BACKSIDE OF THE CEILING SYSTEM. BOM LISTS DESCRIPTIONS THAT COORDINATE WITH THE DATA PAGES, AND THESE ITEM DESCRIPTIONS ARE BASED ON VIEWING THE FACE OF THE PRODUCTS. 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED AT STANDARD 6" OC ROUTE HOLE INCREMENTS ALONG THE MAIN BEAMS - ALL MAIN BEAMS ARE INSTALLED WITH ALIGNED ROUTE HOLES. 3) ANGLE BRACKETS USED WITHIN LAYOUTS HAVE SCREWS, WASHERS, AND NUTS INCLUDED WITH THEM FOR FASTENING TO MAIN BEAMS. IF CORNER BRACKETS ARE USED IN THE SYSTEM THEY WILL REQUIRE SCREWS THAT ARE NOT INCLUDED AND NEED TO BE SUPPLIED BY OTHERS. 4) SCREWS, RIVETS, AND OTHER GENERAL FASTENERS THAT ARE NOT INCLUDED IN BOM OR IN DETAILS BELOW, NEED TO BE SUPPLIED BY OTHERS. REFER TO INSTALLATION INSTRUCTIONS FOR DETAILS ON REQUIRED FASTENERS. 5) HANGER WIRE LOCATIONS SHOWN BELOW ARE ONLY SUGGESTIONS BASED ON EXAMPLE LAYOUT AND CAN BE MOVED IN ACCORDANCE WITH FOLLOWING REQUIREMENT - HANGER WIRES ARE REQUIRED ALONG MAINS WITHIN 24" OF THE WALL AND NO MORE THAN 48" O.C THEREAFTER. 6) CONDITIONS SHOWN ARE FOR NON-SEISMIC INSTALLATIONS (SEISMIC DESIGN CATEGORY A,B) - REFERENCE INSTALLATION INSTRUCTIONS FOR CONSIDERATIONS AND REQUIREMENTS FOR SEISMIC INSTALLATIONS. 7) DETAILS BELOW AND BOM ARE SUBJECT TO CHANGES AT THE PERIMETER BASED ON THE LAYOUT (LINEAR FEET OF PERIMETER, FULL SIZE VS. CUT PANELS, BORDER PANEL INSTALLATION METHOD). 8) 7800 WALL ANGLE PERIMETER SHOWN BELOW. REFERENCE INSTALLATION INSTRUCTIONS FOR DETAILS ON ALTERNATIVE PERIMETER SOLUTIONS. 9) BOM DOES NOT ACCOUNT FOR THE USE OF SCRAP OR EXCESS MATERIAL CUT FROM OTHER ITEMS. 10) REFER TO MASTER PARTS SHEET, PANEL SHEET, AND INSTALLATION INSTRUCTIONS ILLUSTRATIONS SHEET FOR SPECIFIC DETAIL VIEWS AND DIAGRAMS OF ALL PARTS AND PIECES LISTED IN BOM.

SIDE A - REPRESENTS A BORDER CONDITION UTILIZING A SINGLE

GRID MEMBER CONNECTION TO THE PERIMETER

SIDE B - REPRESENTS A BORDER CONDITION UTILIZING A SINGLE

GRID MEMBER CONNECTION OR MULTIPLE GRID MEMBER

CONNECTIONS TO THE PERIMETER

REFERENCE INSTALLATION INSTRUCTIONS FOR FURTHER DETAILS

ON HOW THESE BORDER CONDITIONS ARE INSTALLED

48.59448.000

15.000

24.000

MAIN BEAMS

O.C

48.000HANGER WIRE O.C

24.000

HANGER WIRE

O.C

1

2

9

8

5

3

6

47

10

11

PERIMETER CUT PANELS

AND CROSS TEES

SIDE A

SIDE B

Page 2: 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED … · 3) angle brackets used within layouts have screws, washers, and nuts included with them for fastening to main beams. if

BP73AB45L Prelude

BP75AB45L Suprafine

45° Left Angle Bracket

BP73AB45R Prelude

BP75AB45R Suprafine

45° Right Angle Bracket

BP73AB60L Prelude

BP75AB60L Suprafine

60° Left Angle Bracket

BP73AB75L Prelude

BP75AB75L Suprafine

75° Left Angle Bracket

BP73AB45D Prelude

BP75AB45D Suprafine

45° Double Angle Bracket

BP73AB60D Prelude

BP75AB60D Suprafine

60° Double Angle Bracket

BP73AB60R Prelude

BP75AB60R Suprafine

60° Right Angle Bracket

BP73AB75D Prelude

BP75AB75D Suprafine

75° Double Angle Bracket

BP73AB75R Prelude

BP75AB75R Suprafine

75° Right Angle Bracket

BP73CB45 Prelude

BP75CB45 Suprafine

45° Corner Bracket

BP73CB60L Prelude

BP75CB60L Suprafine

60° Left Corner Bracket

BP73CB60R Prelude

BP75CB60R Suprafine

60° Right Corner Bracket

BPXM734524 Prelude

BPXM754524 Suprafine

45° Cross Tee - 24" MBS

SCALE 1 / 4

BPXM736024 Prelude

BPXM756024 Suprafine

60° Cross Tee - 24" MBS

SCALE 1 / 4

BPXM737524 Prelude

BPXM757524 Suprafine

75° Cross Tee - 24" MBS

SCALE 1 / 4

BPXM734548 Prelude

BPXM754548 Suprafine

45° Cross Tee - 48" MBS

SCALE 1 / 4

BPXM736048 Prelude

BPXM756048 Suprafine

60° Cross Tee - 48" MBS

SCALE 1 / 4

BPXM737548 Prelude

BPXM757548 Suprafine

75° Cross Tee - 48" MBS

SCALE 1 / 4

BPXM7324 Prelude

BPXM7524 Suprafine

Perimeter Cross Tee - 24" MBS

SCALE 1 / 4

BPXM7348 Prelude

BPXM7548 Suprafine

Perimeter Cross Tee - 48" MBS

SCALE 1 / 4

BPPCC

Axiom Perimeter Corner Clip

SCALE 1 / 2

BPPAC

Perimeter Angle Clip

SCALE 1 / 2

DATE:

SCALE:

DRAW

N BY:

PRO

JECT:

These draw

ings show

typical conditions w

hich the A

rm

strong products depicted are installed. T

hey are not a substitute for an architect's or engineer's plan and

do not reflect the unique requirem

ents of local building codes, law

s, statutes, ordinances, rules and regulations (Legal R

equirem

ents) that m

ay be applicable for

a particular installation. A

rm

strong does not w

arrant, and assum

es no liability for the accuracy or com

pleteness of the draw

ings for a particular installation or

their fitness for a particular purpose. T

he user is advised to consult w

ith a duly licensed architect or engineer in the particular locale of the installation to assure

com

pliance w

ith all legal requirem

ents. A

rm

strong is not licensed to provide professional architecture or engineering design services.

10/2/2018

KAPlace

PD

30.425

22.677

16.923

64.366

49.510

41.661

34.000

68.000

DesignFlex Shapes Com

ponents

-

NJFriez
Highlight
NJFriez
Highlight
NJFriez
Highlight
NJFriez
Highlight
Page 3: 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED … · 3) angle brackets used within layouts have screws, washers, and nuts included with them for fastening to main beams. if

Lyra 9/16" Square Tegular - 75 Deg. 12 in Base Right Parallelogram

100020

Lyra 9/16" Square Tegular - 75 Deg. 12 in Base Left Parallelogram

100021

Lyra 9/16" Square Tegular - 75 Deg. 24 in Base Trapezoid

100012

Lyra 9/16" Square Tegular - 45 Deg. 24 in Base Rt. Triangle

100008

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Right Rt. Triangle

100007

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Left Rt. Triangle

100006

Lyra 9/16" Square Tegular - 75 Deg. 24 in Base Triangle

100005

Lyra 9/16" Square Tegular - 60 Deg. 24 in Base Triangle

100002

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Triangle

100003

Lyra 9/16" Square Tegular - 45 Deg. 48 in Base Triangle

100001

Lyra 9/16" Square Tegular - 75 Deg. 12 in Base Triangle

100004

Lyra 9/16" Square Tegular - 75 Deg. 24 in Base Right Parallelogram

100022

Lyra 9/16" Square Tegular - 60 Deg. 24 in Base Right Parallelogram

100016

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Right Parallelogram

100018

Lyra 9/16" Square Tegular - 45 Deg. 48 in Base Right Parallelogram

100014

Lyra 9/16" Square Tegular - 75 Deg. 24 in Base Left Parallelogram

100023

Lyra 9/16" Square Tegular - 60 Deg. 24 in Base Left Parallelogram

100017

Lyra 9/16" Square Tegular - 45 Deg. 48 in Base Left Parallelogram

100015

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Left Parallelogram

100019

Lyra 9/16" Square Tegular - 75 Deg. 48 in Base Trapezoid

100013

Lyra 9/16" Square Tegular - 45 Deg. 96 in Base Trapezoid

100010

Lyra 9/16" Square Tegular - 60 Deg. 48 in Base Trapezoid

100011

Lyra 9/16" Square Tegular - 45 Deg. 48 in Base Rt. Triangle

100009

These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and

regulations (Legal Requirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user

is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. Armstrong is not licensed to provide professional architecture or engineering design services.

DATE: 4/19/2018PDDRAWN BY: KAP

DesignFlex - Panels Lyra Shapes

24

12

48

24

24

24

48

48

24

48

12

24 24

1224

24

48

4848

24

48

24

24

24

24

24

48

24

48

48

48

48

24

48

24

48

24

96

24

24

24

48

48

24

48

48

NOTES:

1. Views are from the face of the panel, and descriptions are based on these views

2. Dimensions are nominal and reflect grid spacings

3. Scale 1:15

NJFriez
Highlight
Page 4: 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED … · 3) angle brackets used within layouts have screws, washers, and nuts included with them for fastening to main beams. if

Calla 9/16" Square Tegular - 75 Deg. 12 in Base Right Parallelogram

100116

Calla 9/16" Square Tegular - 75 Deg. 12 in Base Left Parallelogram

100117

Calla 9/16" Square Tegular - 75 Deg. 24 in Base Trapezoid

100110

Calla 9/16" Square Tegular - 45 Deg. 24 in Base Rt. Triangle

100107

Calla 9/16" Square Tegular - 60 Deg. 48 in Base Right Rt. Triangle

100106

Calla 9/16" Square Tegular - 60 Deg. 48 in Base Left Rt. Triangle

100105

Calla 9/16" Square Tegular - 75 Deg. 24 in Base Triangle

100104

Calla 9/16" Square Tegular - 60 Deg. 24 in Base Triangle

100101

Calla 9/16" Square Tegular - 60 Deg. 48 in Base Triangle

100102

Calla 9/16" Square Tegular - 45 Deg. 48 in Base Triangle

100100

Calla 9/16" Square Tegular - 75 Deg. 12 in Base Triangle

100103

Calla 9/16" Square Tegular - 75 Deg. 24 in Base Right Parallelogram

100118

Calla 9/16" Square Tegular - 60 Deg. 24 in Base Right Parallelogram

100114

Calla 9/16" Square Tegular - 45 Deg. 48 in Base Right Parallelogram

100112

Calla 9/16" Square Tegular - 75 Deg. 24 in Base Left Parallelogram

100119

Calla 9/16" Square Tegular - 60 Deg. 24 in Base Left Parallelogram

100115

Calla 9/16" Square Tegular - 45 Deg. 48 in Base Left Parallelogram

100113

Calla 9/16" Square Tegular - 75 Deg. 48 in Base Trapezoid

100111

Calla 9/16" Square Tegular - 60 Deg. 48 in Base Trapezoid

100109

Calla 9/16" Square Tegular - 45 Deg. 48 in Base Rt. Triangle

100108

These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and

regulations (Legal Requirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user

is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. Armstrong is not licensed to provide professional architecture or engineering design services.

DATE: 4/19/2018PDDRAWN BY: KAP

DesignFlex - Panels Calla Shapes

24

12

48

24

24

24

48

48

24

48

12

24

12

24 24

24

24

48 48

24

48

48

NOTES:

1. Views are from the face of the panel, and descriptions are based on these views

2. Dimensions are nominal and reflect grid spacings

3. Scale 1:15

24

24

24

24

24

48

24

48

24

48

48

48

24

24

48

24

24

48

NJFriez
Highlight
Page 5: 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED … · 3) angle brackets used within layouts have screws, washers, and nuts included with them for fastening to main beams. if

Optima 9/16" Square Tegular - 75 Deg. 12 in Base Right Parallelogram

100219

Optima 9/16" Square Tegular - 75 Deg. 12 in Base Left Parallelogram

100220

Optima 9/16" Square Tegular - 75 Deg. 24 in Base Trapezoid

100211

Optima 9/16" Square Tegular - 45 Deg. 24 in Base Rt. Triangle

100207

Optima 9/16" Square Tegular - 60 Deg. 48 in Base Right Rt. Triangle

100206

Optima 9/16" Square Tegular - 60 Deg. 48 in Base Left Rt. Triangle

100205

Optima 9/16" Square Tegular - 75 Deg. 24 in Base Triangle

100204

Optima 15/16" Lay-In - 75 Deg. 24 in Base Triangle

100227

Optima 9/16" Square Tegular - 60 Deg. 24 in Base Triangle

100201

Optima 9/16" Square Tegular - 60 Deg. 48 in Base Triangle

100202

Optima 15/16" Lay-In - 60 Deg. 48 in Base Triangle

100225

Optima 9/16" Square Tegular - 45 Deg. 48 in Base Triangle

100200

Optima 9/16" Square Tegular - 75 Deg. 12 in Base Triangle

100203

Optima 9/16" Square Tegular - 75 Deg. 24 in Base Right Parallelogram

100221

Optima 15/16" Lay-In - 75 Deg. 24 in Base Right Parallelogram

100244

Optima 9/16" Square Tegular - 60 Deg. 24 in Base Right Parallelogram

100215

Optima 9/16" Square Tegular - 60 Deg. 48 in Base Right Parallelogram

100217

Optima 15/16" Lay-In - 60 Deg. 48 in Base Right Parallelogram

100240

Optima 9/16" Square Tegular - 45 Deg. 48 in Base Right Parallelogram

100213

Optima 9/16" Square Tegular - 75 Deg. 24 in Base Left Parallelogram

100222

Optima 15/16" Lay-In - 75 Deg. 24 in Base Left Parallelogram

100245

Optima 9/16" Square Tegular - 60 Deg. 24 in Base Left Parallelogram

100216

Optima 9/16" Square Tegular - 45 Deg. 48 in Base Left Parallelogram

100214

Optima 9/16" Square Tegular - 60 Deg. 48 in Base Left Parallelogram

100218

Optima 15/16" Lay-In - 60 Deg. 48 in Base Left Parallelogram

100241

Optima 9/16" Square Tegular - 75 Deg. 48 in Base Trapezoid

100212

Optima 15/16" Lay-In - 75 Deg. 48 in Base Trapezoid

100235

Optima 9/16" Square Tegular - 45 Deg. 96 in Base Trapezoid

100209

Optima 9/16" Square Tegular - 60 Deg. 48 in Base Trapezoid

100210

Optima 9/16" Square Tegular - 45 Deg. 48 in Base Rt. Triangle

100208

Optima 15/16" Lay-in - 45 Deg. 48 in Base Rt. Triangle

100231

These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and

regulations (Legal Requirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user

is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. Armstrong is not licensed to provide professional architecture or engineering design services.

DATE: 4/19/2018PDDRAWN BY: KAP

DesignFlex - Panels Optima Shapes

24

12

48

24

24

24

48

48

24

48

12

24 24

1224

24

48

4848

24

48

24

24

24

24

24

48

24

48

48

48

48

24

48

24

48

24

96

24

24

24

48

48

24

48

48

NOTES:

1. Views are from the face of the panel, and descriptions are based on these views

2. Dimensions are nominal and reflect grid spacings

3. Scale 1:15

NJFriez
Highlight
Page 6: 2) ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED … · 3) angle brackets used within layouts have screws, washers, and nuts included with them for fastening to main beams. if

Ultima 9/16" Beveled Tegular - 75 Deg. 12 in Base Right Parallelogram

100315

Ultima 9/16" Beveled Tegular - 75 Deg. 12 in Base Left Parallelogram

100316

Ultima 9/16" Beveled Tegular - 75 Deg. 24 in Base Trapezoid

100310

Ultima 9/16" Beveled Tegular - 45 Deg. 24 in Base Rt. Triangle

100307

Ultima 9/16" Beveled Tegular - 60 Deg. 48 in Base Right Rt. Triangle

100306

Ultima 9/16" Beveled Tegular - 60 Deg. 48 in Base Left Rt. Triangle

100305

Ultima 9/16" Beveled Tegular - 75 Deg. 24 in Base Triangle

100304

Ultima 9/16" Beveled Tegular - 60 Deg. 24 in Base Triangle

100301

Ultima 9/16" Beveled Tegular - 45 Deg. 48 in Base Triangle

100300

Ultima 9/16" Beveled Tegular - 75 Deg. 12 in Base Triangle

100303

Ultima 9/16" Beveled Tegular - 60 Deg. 24 in Base Right Parallelogram

100313

Ultima 9/16" Beveled Tegular - 60 Deg. 24 in Base Left Parallelogram

100314

Ultima 9/16" Beveled Tegular - 60 Deg. 48 in Base Trapezoid

100309

These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and

regulations (Legal Requirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user

is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. Armstrong is not licensed to provide professional architecture or engineering design services.

DATE: 4/19/2018PDDRAWN BY: KAP

DesignFlex - Panels Ultima Shapes

24

12

48

24

24

24

24

48

12

24 24

12

24

24

24 24

48

24

24

24

24

48

48

24

NOTES:

1. Views are from the face of the panel, and descriptions are based on these views

2. Dimensions are nominal and reflect grid spacings

3. Scale 1:15

24