1
Plot 1 79.250 Plot 2 79.000 Phase 2 Area for development (this application) 13330m² 1.33 Hectares Phase 1 Area (Previous application only) 8066m² 0.81 Hectares Plot 3 79.000 Plot 4 79.500 Plot 5 80.000 Plot 6 79.750 Plot 7 79.500 Plot 8 79.000 29 Bocam Park, Old Field Road, Pencoed, Bridgend CF35 5LJ. Phone: 01656 863794 Email: [email protected] Project number ALL DIMENSIONS TO BE CHECKED ON SITE: Contractor to check and verify all building and site dimensions. The Contractor is to comply in all respects with the current Building Regulations whether specifically stated on this drawing or not. This drawing must be read and checked against any other specialist drawings provided & manufacturer's recommendations. Tabled quantities are for guidance only all specialist Consultants & Contractors to check and verify. Any discrepancies in all of the above must be reported to the Design team prior to installation CDM - If we are appointed as a Designer or Principal Designer, for the Pre - Construction Phase only, we can only carry out our duties for that phase. This means that we will give all relevant design information for consideration in the Construction Phase Plan / Health & Safety File to the Client at the end of the Pre - Construction Phase. It will be the Client’s responsibility to pass that information on to the Principal Contractor and any other Contractors or Designers, which the client subsequently appoints. System Number NOTES drawn status drg. no. scale @ A0 date Title rev. checked approved Project apprvd. rev. drawn chkd. date description Client 1. All dimensions are in millimetres unless noted otherwise. 2. All levels are shown in millimetres unless noted otherwise. 3. Do not scale from the drawing. Use figured dimensions only. 4. Any discrepancies to be reported immediately to the Designer/Engineer. 5. This drawing to be read in conjunction with all relevant Architects, engineers, subcontractors and specialists drawings and specifications. 1 : 500 Phase 2 Proposed Site Plan 9304 Llantrisant Business Park Allied Welsh & Ty Carreg Group March 2018 ND MJ 124 On Land at Tal y Fedw Llantrisant Business Park, Llantrisant, CF72 8LF ND/18 - 010 - b/9304 planning 1 : 500 Site plan 1 Isometric 1 - Phase 2 2 Isometric 2 - Phase 2 3 Isometric 3 - Phase 2 4 Marked Parking for 3 cars per unit (to include 1no disabled bays over the 5% required) Areas: Operational - Green hatch at 973m2 Non - Operational - Cyan hatch at 265m2 Unit 1 to drawing AW01 Boundary treatment in accordance to the current Planning application submitted by Tom Pritchard (16/1251) Blue line indicates the site total outline Red line indicates the outline site affected by this application Marked Parking for 3 cars per unit (to include 1no disabled bays over the 5% required) Areas: Operational - Green hatch at 121m2 Non - Operational - Cyan hatch at 76m2 Marked Parking for 3 cars per unit (to include 1no disabled bays over the 5% required) Areas: Operational - Green hatch at 705m2 Non - Operational - Cyan hatch at 337m2 Possible PROW diversion subject to approved application currently being processed (green dashed line) Line of existing PROW One way system to vehicle tracking layouts KEY S1 - Metal frame bike shelter, paint/powder coating colour to match the building trims - Roof formed with clear poly carbonate sheets (holds up to 10 bikes) S2 - Embankment regraded and seeded S3 - New Indigenous hedgerow - in accordance with ecology report S4 - New Indigenous Trees - in accordance with ecology report S5 - 1.8m Feather edge board timber board fence and lockable gates for perimeter or bins and plant S6 - Permeable tarmac to the footpaths, all access points to have a level threshold S7 - Permeable tarmac to the vehicle hardstand to details provided S8 - New flood lighting S9 - Powder coated Wide Mesh anti climb fencing - by the owner of the Neighbouring site
Transcript
Page 1: 2 Isometric 1 - Phase 2 · status drg. no. scale @ A0 date Title rev. checked approved Project a p p r v d. r e v. d r a w n c h k d. d a t e description ... Isometric 1 - Phase 2

Plot 179.250

Plot 279.000

Phase 2 Area for development(this application)

13330m²1.33 Hectares

Phase 1 Area (Previous application only)

8066m²0.81 Hectares

Plot 379.000

Plot 479.500

Plot 580.000

Plot 679.750

Plot 779.500

Plot 879.000

29 Bocam Park, Old Field Road, Pencoed, Bridgend CF35 5LJ.Phone: 01656 863794 Email: [email protected]

Project number

ALL DIMENSIONS TO BE CHECKED ON SITE: Contractor to check and verify all building and site dimensions. The

Contractor is to comply in all respects with the current Building Regulations whether specifically stated on this drawing or not. This drawing must be read and checked

against any other specialist drawings provided & manufacturer's recommendations. Tabled quantities are for

guidance only all specialist Consultants & Contractors to check and verify. Any discrepancies in all of the above must

be reported to the Design team prior to installation

CDM - If we are appointed as a Designer or Principal Designer, for the Pre-Construction Phase only, we can only carry out our duties for that phase. This means that we will give all relevant design information for consideration in the Construction Phase Plan / Health & Safety File to the Client

at the end of the Pre-Construction Phase. It will be the Client’s responsibility to pass that information on to the

Principal Contractor and any other Contractors or Designers, which the client subsequently appoints.

System Number

NOTES

drawn

status drg. no.

scale @ A0

date

Title

rev.

checked approved

Project

appr

vd.

rev.

draw

n

chkd

.

date description

Client

1. All dimensions are in millimetres unless noted otherwise.2. All levels are shown in millimetres unless noted otherwise.3. Do not scale from the drawing. Use figured dimensions only.4. Any discrepancies to be reported immediately to the

Designer/Engineer.5. This drawing to be read in conjunction with all relevant

Architects, engineers, subcontractors and specialistsdrawings and specifications.

1 : 500

Phase 2 Proposed Site Plan

9304

Llantrisant Business Park

Allied Welsh & Ty Carreg Group

March2018 ND MJ

124

On Land at Tal y FedwLlantrisant Business Park,

Llantrisant, CF72 8LF

ND/18-010-b/9304

plan

ning

1 : 500Site plan1

Isometric 1 - Phase 22

Isometric 2 - Phase 23

Isometric 3 - Phase 24

Marked Parking for 3 cars per unit (to include 1no disabled bays over the 5% required)

Areas: Operational - Green hatch at 973m2Non-Operational - Cyan hatch at 265m2

Unit 1 to drawing AW01

Boundary treatment in accordance to the current Planning

application submitted by Tom Pritchard

(16/1251)

Blue line indicates the site total outline

Red line indicates the outline site affected by this

application

Marked Parking for 3 cars per unit (to include 1no disabled bays over the 5% required)

Areas: Operational - Green hatch at 121m2Non-Operational - Cyan hatch at 76m2

Marked Parking for 3 cars per unit (to include 1no disabled bays over the 5% required)

Areas: Operational - Green hatch at 705m2Non-Operational - Cyan hatch at 337m2

Possible PROW diversion subject to approved application currently being

processed (green dashed line)

Line of existing PROW

One way system to vehicle tracking layouts

KEY

S1 - Metal frame bike shelter, paint/powder coating colour to match the building trims - Roof formed with clear poly carbonate sheets (holds up to 10 bikes)

S2 - Embankment regraded and seeded

S3 - New Indigenous hedgerow - in accordance with ecology report

S4 - New Indigenous Trees - in accordance with ecology report

S5 - 1.8m Feather edge board timber board fence and lockable gates for perimeter or bins and plant

S6 - Permeable tarmac to the footpaths, all access points to have a level thresholdS7 - Permeable tarmac to the vehicle hardstand to details provided

S8 - New flood lighting

S9 - Powder coated Wide Mesh anti climb fencing - by the owner of the Neighbouring site

Recommended