BRUNDLE2 LEAF TELESCOPIC SLIDING GATE KIT
This kit is made of galvanized steel components ideal for installation on sliding gates. A steel wire is used to transfer the telescopic motion. A gate with this system can be motorized. The leaves move simultaneously sliding on ground rails and have the advantage of taking less space compared to a single ground track sliding gate when the gate is in the open position. This feature makes the product ideal for sites where space is limited.
DESCRIPTION
S2
S1
COMPONENT LIST
ACCESSORIES
TELESCOPIC TRANSMISSION SET
16mm ROUND GROOVED TRACK
Concrete-in
Code: 05GD616Z3
COUPLING
UPPER GUIDE ROLLER
Code: 05GD118
ADJUSTABLE ROLLER PLATE GUIDE
ROUND GROOVED WHEEL
For 16mm track
Code: 0515060
COVERFor telescopic transmission set
CONNECTION ROLLERS
Gate rollers and track are not included with this kit. See below for additional components.
Page 1 of 6
Ø 35mmM8
M8
M8
60mm
Min. 100mm53mm
23.5mm50mm
15mm99mm
NO
~25mm
~25mm
1 2
3 4
1
3
5
2
4
6
S1
S1
S1
S1
S1
Code: 39TK2004 / 008
Code: 39TK2114
Page 2 of 6
20mm
30mm
100mmS1 S2
1
2
3
C
D
7
9
11
8
10
12
S1
S1
Code: 39TK2004 / 008
Code: 39TK2004 / 008
1 x Code: 39TK2004 / 008
Code: 39TK2114
Code: 39TK2114
2 x Code: 39TK2114
S1
S1
Page 3 of 6
1
3
2
S1S2
100mm
S1S2
L
Safety screwsMax. 10mm
13
15
17
14
16
18
Code: 39TK2004 / 008
Code: 39TK2114
S1
S1
S2
S1
Page 4 of 6
DIMENSIONS TABLE
SECTION DIMENSIONS
B A
S2 S1
C
C
D
L
T
50+TL = [(A+B)/2]+C
(50) mm
Important
CodeA max
(m)C
(m)D min(mm)
S2 max(kg)
39TK2004 4.0 0.3 50 30039TK2008 8.0 0.3 50 30039TK2114 11.4 0.6 70 400
Opening(A) Code L (m)
with B = 0.08
3 39TK2004 1.844 39TK2004 2.345 39TK2008 2.846 39TK2008 3.347 39TK2008 3.848 39TK2008 4.349 39TK2114 5.1410 39TK2114 5.6411 39TK2114 6.14
A = 3.5mB = 0.06m (your choice)C = 0.3m (see table above)L = [(A+B)/2]+CL = [(3.5+0.06)/2]+0.3L = [(3,56)/2]+0.3L = 1.78+0.3L = 2.08
Example of dimensions not in table
Page 5 of 6
May 2019
www.fhbrundle.co.ukTel. 01708 25 35 45 [email protected]
Whilst every effort has been made to ensure the accuracy of the information supplied. F.H.Brundle cannot be held responsible for any errors or omissions. This product must only be employed for its original intended use. Any other use is wrong and potentially dangerous. Installation must be carried out in full compliance with current regulations. F.H.Brundle cannot be held liable for any damages resulting from wrongful, erroneous or negligent use.
Attention: installations that do not comply with the illustrated procedure or failure to carry out correct maintenance operations can cause the gate to derail and endanger the safety of people and property.
To maintain the parts in good and safe working order it is necessary to follow these steps:
1. After gate assembly is completed, perform a few manual open/close cycles to make sure there are no loose parts. Ensure the cable is lubricated along its entire length with supplied oil (pic.10). Check the system every 3 months or after a maximum 8000 cycles to make sure there are no loose parts and that the system is properly lubricated
2. In case of loose cable check all clamps and follow the tensioning procedure3. In case of accidental impact caused by moving vehicles or other external factors, check parts for external damage. If there
is irreparable damage, replace with a new part. Always check the gate by manually performing a few open/close cycles. All maintenance procedures must be performed by trained technicians
4. If the gate has any difficulty of movement or shows abnormal oscillations, the gate must be checked for worn parts which must be replaced if necessary. Gates working in harsh ambient conditions, such as hight humidity, salt, acids, dust or temperatures above 120°C will require special attention and frequent maintenance
1. The installation of safety strikes and safety screws (pic.18) is compulsory2. To select the right automation, it is necessary to calculate the weight of the gate by adding 2 times the weight of the second
leaf S2 to 1 times the weight of the first leaf S1 • Calculate mass = Weight S1 + (2 x Weight S2)
3. Recommended automation: 24V DC4. The ideal traction is one that is just enough to keep the wire stretched. An excessive traction of the wire will shorten its
working life5. Maximum S2 closing speed = 0.18m/s
• Fast and hard start/stops will result in system failure • Accelerations, decelerations and high speed variations could cause an elastic effect between the leaves
MAINTENANCE
TECHNICAL SPECIFICATION
Page 6 of 6