SRX-R220/210 Power Requirements or R220/210, single-phase power supply switches automatically and can accept 00v to 250v AC. he three-phase power supply for the lamp must be set manually to ither 200V or 400V,depending on the standard voltage in the country here the projector is installed. n shipment, it is set to 200V. hree-phase power voltage setting Single-phase AC INLET Three-phase L1/L2/L3/N/PE Connection of AC power supply Connections Picture inputs A~C, Ethernet, Inter lock
8
SRX-R220/210 Power Requirements
Transcript
Page 1: 2 - Power supply and lamp power

SRX-R220/210 Power Requirements

Page 2: 2 - Power supply and lamp power

Three-phase power voltage setting

For R220/210, single-phase power supply switches automatically and can accept100v to 250v AC. The three-phase power supply for the lamp must be set manually to either 200V or 400V,depending on the standard voltage in the country where the projector is installed.On shipment, it is set to 200V.

*For setting, make sure to turn off the power. Check the setting Voltage

Page 3: 2 - Power supply and lamp power

Connection of AC power supply

L1L2L3 PEN

Three-phaseL1/L2/L3/N/PE

Single-phaseAC INLET

Page 4: 2 - Power supply and lamp power

Connections

Picture inputs A~C, Ethernet, Inter lock

Page 5: 2 - Power supply and lamp power

Safety Interlock

• What is Safety Interlock?– Legal Safety Feature– Shuts down projector when cinema fire alarm

activated– Normally simple open or closing contact

• R220/210 has a 15 pin connector

Page 6: 2 - Power supply and lamp power

R220 R210Correspondence lamp 4.2KW (LKRX-2042A) 3.0KW (LKRX-2030A)

2.0KW (LKRX-2020A)Light output(When the screen gain is 1.8)

14ft-L (@ 20m Screen) 14ft-L (@ 17m Screen)14ft-L (@ 14m Screen)

Current value Single-phase   11-5A ( 100-240V )   Three-phase   21A/11A ( 200-208V/ 380-415V )

Single-phase   11-5A ( 100-240V )   Three-phase   13.5/7A ( 200-208V/ 380-415V )

Setting of mode of lamp power supply

Mode:B Mode:C

Difference point list R220 and R210

Page 7: 2 - Power supply and lamp power

Setting of mode of lamp power supply for 4.2Kw, 3Kw, 2Kw lamp

MODE B

MODE C

R220

R210

Page 8: 2 - Power supply and lamp power

Luminance sensor and Lamp wattage

R220/210 is equipped with a luminance sensor in the optical unit.When the LAMP POWER is changed, the luminance sensor value (not the LAMP POWER value) is saved.

After Calibration, the table of the Lamp power and the Luminancesensor value is revised. When recalling the FUNCTION MEMORY, the lamp power is automatically set so that the luminance is maintained.

Lamp power Luminance sensor value

100 1000

90 800

80 600

70 400

60 200

Lamp power Luminance sensor value

100 800

90 600

80 400

70 200

60 0

CALIBRATE