Siemens Building Technologies Building Technologies
SED2 Drive Applications
Siemens Building Technologies Building Technologies
Simple Applications
INPUTS OUTPUTS
ACTION
0-10 V
On
FaultReset
Relay 1-> Fault
Relay 2-> Run
Siemens Building Technologies Building Technologies
Standard I/O
0-10 V
2-10 V
0-20 mA
4-20 mA
Programmablefunctions
Form C contacts
Programmablefunctions
30VDC, 5A
240VAC, 2A
2 x analog outputs
2 x digital outputs
RS-485
P1
N2
USS
LonWorks (opt.)
Modbus (opt.)
0-10 V
2-10 V
0-20 mA
4-20 mA
Ni 1000
2 x analog inputs
6 x digital inputs
1 x motor PTC
Insulated
Programmablefunctions
PNP or NPN (sink/source)
SED2
Siemens Building Technologies Building Technologies
Application - Air Temperature Control, Cooling
TSP=25°C
100 %
0 %SED 2
SPTC
M
p
BI ~3 AI
BI
Digital Input Analog Input
Digital Input
Function Description-Exhaust fan –-Air flow monitoring (External, only alarm)-Room temperature control, cooling-Sensor Ni 1000 -Set point +25°C-Thermostat for switch on/off
Siemens Building Technologies Building Technologies
Solution: PID Controller Direct Sensor Connection
Ni 1000Sensor
Ni 1000 Temperature Sensor
Drive Based PID w/ Hibernation Mode
Siemens Building Technologies Building Technologies
Ni 1000 I/O
SED2
Ni 1000 Analog input
Digital input1 Safety Input
Siemens Building Technologies Building Technologies
Function Description-Constant pressure (P)-Pump Logic Controller (B&G Buster package)-P1, P2 and P3 on-off with motor starters
P3
P1
P2
M
SED 2
SP
M
M
BO BO
P
~3
PC
100 %
P
SP=2.5 bar
0 % P1
P1
P1
P2
P3
Application - Water Pressure Control
Siemens Building Technologies Building Technologies
Solution: Built-In Pump Cascading
P
This function allows for control of up to two additional, cascaded pumps. With the two relay output contacts, the SED2 performs the cascading logic without additional controllers or I/O cards.
-No separate controller required
-Energy savings with SED2
Pre
ssu
re d
em
an
d
100%
2. 3.1.
Cascade
Siemens Building Technologies Building Technologies
SED2
Pump Staging I/O
2 x analog input
6 x digital input 2 x digital output
0-10 volt
Pressure
Transmitter
1 On Command
1 safety input
2nd stage pump
3rd stage pump
Siemens Building Technologies Building Technologies
Application – Temp. Control + Belt Monitoring
Function Description-Exhaust fan –-Air flow monitoring (External, only alarm)-Room temperature control, cooling-Sensor Ni 1000 -Set point +25°C-Thermostat for switch on/off-Belt monitoring
SED 2
SPTC
M
p
BI ~3 AI
BI
TSP=25°C
100 %
0 %
Siemens Building Technologies Building Technologies
Solution: V-Belt Monitoring
The SED2 ensures reliable V-belt monitoring without the expense of an external sensor. Both speed and torque are compared to a user-defined tolerance band. If the parameters do not match, the drive trips in the event of V-belt failure.
Also, the SED2 is able to monitor a pulse sequence from the sensor detecting rotation of the fan shaft.
Speed
Torque
Siemens Building Technologies Building Technologies
Application – Temp. Control + Duct Pressure Control
Function Description-Exhaust fan = Like air temperature control example-Air flow monitoring (External, only alarm)-Static pressure control-0-10v, 1-4inch wg-Set point 2.5 inch-Thermostat for switch on/off
IWGSP=2.5
100 %
0 %SED 2
SPTC
M
p
BI ~3 AI
BI
Siemens Building Technologies Building Technologies
Solution: Duct Pressure Control
• 0 – 10 Volt standard output signal
• 1% Accuracy over full scale
• Available in uni-directional ½”, 1”, 2” and 5” wc
• Available in bi-directional ¼” wc.
Speed Reduction
Pressure
Siemens Building Technologies Building Technologies
Static Pressure Control I/O
2 x analog input
6 x digital input
SED2
0-10 volt
Pressure
transmitter
1 On Command
1 Safety
Static Pressure Switch
Siemens Building Technologies Building Technologies
Bundled Package
The SED2 is equipped with TEC application 2722
Which includes 99 subpoints
for monitoring and control
(See Attached Document for TEC Schedule)
Siemens Building Technologies Building Technologies
Control Board
2 0 2 1 2 2 2 3 2 4 2 5
2 9 3 01 7 2 6 2 7 2 81 2 1 3 1 4 1 5 1 6
1 0 1 16 7 8 91 2 3 4 5
ON
1
RL1NC
RL1NO
RL1COM
RL2NC
RL2NO
RL2COM
AOUT1+
AOUT1-
PTCA
PTCB
DIN5
DIN6
AOUT2+
AOUT2-
ISO0V
P+ N-
RS-485
10V 0V AIN1+
AIN1-
DIN1
DIN2
DIN3
DIN4
ISO24V
AIN2+
AIN2-
AIN1On = [A], 0 - 20 mAOff = [V], 0 - 10 V
AIN2On = [A], 0 - 20 mAOff = [V], 0 - 10 V
V: 0 - 10 V2 - 10 V
I: 0 - 20 mA4 - 20 mA
P1; N2 USS
ErrorRun
Fn
2
519
2Z2
8en
DIN1 - I/ODIN2 - ReverseDIN3 - Fault acknowledge /
Siemens Building Technologies Building Technologies
Control Terminals
Digital Inputs Terminals Parameter Default
1 5 P0701=1 ON right
2 6 P0702=12 Reverse
3 7 P07a03=9 Fault Acknowledge
4 8 P0704=15 Fixed Frequency
5 16 P0705=15 Fixed Frequency
6 17 P0706=15 Fixed Frequency
Digital Outputs Terminals Parameter Default Operation
1 18,19,20 P0731 Drive fault
2 23,24,25 P0732 Drive running
Analog Inputs * Terminals Parameter Default Operation
1 3,4 P0756(0) 0-10V dc
2 10,11 P0756(1) 0-10V dc
Analog Outputs Terminals Parameter Default Operation
1 12,13 P0771(0) Frequency
2 26,27 P0771(1) Frequency
* Can also be configured as NI1000 inputs.
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
• Type of environment
- What is the location like? Does it fall within the drives operating ranges for altitude & temperature
• Type of power
- Line and load reactors reduce voltage. If voltage is already low, using them could have an effect on performance.
- Does the power system supply at least 1% impedance?• Type of motor
- Is it VFD rated?
- Distance from the drive?
- HP of the motors?
- Age of the motor?
Siemens Building Technologies Building Technologies
Enclosure Ratings - Drive & Drive W/Bypass
• IP 20– No NEMA equivalent, needs to be mounted in another
enclosure– Generally used in US for OEM applications– Our standard unit as it comes from the factory
• IP 21– NEMA 1, protects operator from electrical hazard and
protects the equipment from falling material– Our standard unit when fitted with gland plate and dust
cover
• IP 54– No direct US equivalent, but exceeds NEMA 12– NEMA 3R– Water tight, limited need in drive applications
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
Line Reactor Installation• Not recommended to reduce Harmonics• Can be ordered with or without an enclosure• Installed to protect the drive from:
– Power spikes or sags caused from transfer to generator– Poor heavy switch load on the same load center
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
Load Reactor Installation• Long wire leads from drive to motor
– As wire length from drive to motor increases, the voltage spike increases – Can be ordered with or without an enclosure– Installed to protect the motor from:– Spikes caused from the drive switching frequencies or IGBT
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
Line and Load Reactor Installation• Always use Siemens Building Technologies specified
reactor• For retro-fit applications
– REMOVE AND REPLACE EXISTING REACTORS WITH SBT SPECIFIED REACTORS
Siemens Building Technologies Building Technologies
Siemens SED2 VFD Advantages
• Low harmonics design• Small enclosure size• Many standard
features• Reduces operating
cost• Low power losses/high
efficiency• Minimal effect on
customer power• Wide power range –
from ½ to 125 HP