Z-One® Digital Power
Analog POL
Isolated DC-DC
Hot-Swap
Chassis Mount
PoE
Ruggedized
CompactPCI
Alternative Energy
Power Systems
Intelligent Controls
2007 Product Update
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Board MountIsolated DC-DC
NonBrick
1/16Brick
1/8Brick
1/4Brick
1/2Brick
3/4Brick
FullBrick
IBA Bus Converters 1212 12 12
Power over Ethernet 13
Single Output - SMT 9 7 7 8
Single Output - TH 18 13 14 15 17 18 18
Dual Output - SMT 11 10
Dual Output - TH 24 21 22 22
Triple Output - TH 28 27
Quad Output - TH 31
Input Filters - SMT 11
Input Filters - TH 32
Dis
trib
ute
d P
ower
& In
term
edia
te B
us
Arc
hit
ectu
res
DPA & IBA OverviewPage 3
Table of ContentsS
ite
Lev
el
A Company Overview is Located on Page 2
SMT = Surface MountTH = Through Hole
Hot-Swap & Chassis-Mount Front Ends
Hot-Swap Single Output 4
Hot-Swap Power Shelves 5
Hot-Swap Multiple Output 6
Chassis-Mount Single Output 38
Point-Of-Load Conversion & Management
Z-One®
DigitalPower
Z-7000 Series POLs & Digital Power ManagersI2C Compatible Programming, Optional GUI
33
Z-1000 No-BusTM POL ConvertersNo External Controllers or Software Required
33
Analog Y-Series POLs Available in Industry-StandardSMT and Thru-Hole Footprints
35
Alternative EnergyPhotovoltaic Inverters 78
Wind Inverters 79
Power SystemsRectifier & Shelf Solutions 73
Indoor & Outdoor Cabinets 73
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
DIN-Rail Mount, AC-DC & DC-DCLOK, LOR, LOS, and LPDS Series 60
W Series, Includes EN50155 Models 60
X Series with PFC 61
Battery Chargers 61
Board-Only, U-Channel, & EnclosedDC-DC Single, Triple, & Quad Output 47
AC-DC Single Output 30 to 7000 Watts 38
AC-DC Dual Output 80 to 150 Watts 40
AC-DC Triple Output 37 to 150 Watts 40
AC-DC Quad Output Under 100 Watts 43
110 to 125 Watts 44
130 to 150 Watts 44
200 to 250 Watts 45
375 to 400 Watts 46
A Listing of Recent Technical Articles is Located on Page 80
Any Voltage, Any Current, Any Power ArchitectureC
has
sis
Mo
un
t,u
p t
o 7
000
Wat
ts
Low Power Products OverviewPage 37
Sp
ecia
lty
Rai
lway
& R
ugg
ed
Railway& Rugged OverviewPage 59
Co
ntr
ols
CompactPCI & PoEAC-DC CompactPCI 57
DC-DC CompactPCI 57
Power Over Ethernet 58
Configurable ModularESP Series - Up to 12 Outputs & 1000 Watts 48
ESM Series - Up to 12 Outputs & 1000 Watts, Medical Approvals 48
High Power - Up to 21 Outputs, 1000 to 4000 Watts 50
Digital Monitoring & Control CapabilitiesIntelligent Motor Controls 77
HIQgrid Control System 77
i.illumination Streetlight Monitoring 77
Open-Frame LinearsSingle Output 54
Dual Output 55
Triple Output 56
Cassettes & Positive Switching RegulatorsDC-DC Cassettes K
67M64
S65
P68
Q66
AC-DC Cassettes M70
H70
S71
S/PFC71
K71
K/PFC71
KP/PFC71
Cassette Battery Chargers 72
Positive Switching Regulators 62
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
2
Power-One’s industry-leading product breadth powers adiverse array of high-availability infrastructure systems.Applications include alternative energy inverters, wireless,
broadband, high-end data server/storage, intelligent motorcontrols, medical diagnostic, optical networking, railway,routers, and semiconductor-test equipment.
Infrastructure Power for an On-Demand World
Data and VoiceCommunications
Servers andData Storage
Manufacturing andTest Equipment
Medical Imagingand Diagnostic
Industrial and Transportation
Manufacturing capabilities include a high-volume, low-cost facility in Shenzen China.
Competitive on a World-Class LevelGlobal presence, technology leadership, and local customer supportcontribute to making Power-One competitive on a world-class level.Strategically-located North American, European, and Asian operationsfacilitate industry-leading support for global customers. Corporateheadquarters are located in Camarillo, California.
Power-One employs over 4,000 people worldwide. All facilities arecertified to ISO standards, including joint ventures and contractmanufacturing partnerships.
One of the key elements of Power-One’s customer-focusedmanufacturing strategy is the ability to quickly adjust capacity throughthe coordination of joint ventures, contract manufacturers, and wholly-owned facilities.
Changing the Shape of Power for Over 30 Years1973 1997 1998 1999 2000 2001 2003 2004 2005 2006
Founded as an AC-DCproducts company
Publicly traded onNasdaq as PWER
Melcher acquisitionenhances global presence
Enters system-power market byacquiring HC Power and Powec
IPD acquisition expandsDC-DC offerings
Silicon initiative establishesdigital-power R&D center
di/dt acquisition addsmore DC-DC products
Introduces industry’s firstdigital power products
Forms Z-Alliance to providemulti-source digital products
Increases focus ondata storage andserver markets
• Vaults Power-One into the world’s “Top 6” power supply companies• Provides high-volume, low-cost manufacturing in China• Top-tier R&D talent added to expand growth in custom products• Provides entry into the fast growing Alternative Energy market with a
broad line of solar and wind power inverters
Power-One Acquires Magnetek’s Power Electronics Group
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Single &Multiple OutputDPA Solutions
3
DPA & IBA Solutions Overview
Saving Energy with a Comprehensive Range of High-Efficiency ProductsPower-One’s products save energy by providing some of theindustry’s highest power-conversion efficiencies. Additional energysavings can be realized by optimizing DPA and IBA bus voltages;which can reduce I2R losses and improve the efficiencies of isolateddc-dc and POL converters. Power-One’s broad array of products,many with adjustable outputs, provide a broad range of voltage values
to select from, ensuring that an optimum-value bus voltage isavailable for any DPA, IBA, or hybrid-architecture application. Power-One’s industry-leading efficiencies, combined with advanced thermal-management techniques, can also save valuable system space byfacilitating increased power densities.
Bus Converters & Isolated DC-DC
Single OutputIBA Bus Converters
Digital & Analog POL Conversion & Management
Analog POLConverters
Z-7000 POLs andDigital Power Managers
Z-1000 DigitalNo-Bus POLs
Sync/Data Line Pin Strapping
DPA, IBA, and HybridArchitecture Solutions
AC-DC & DC-DCHot-Swap Front Ends
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Hot Swap Front Ends > Single Output
4
Power-One offers a broad array of DPA & IBA hot-swap frontends. Chassis-mount front ends are also available and arelisted in the Chassis Mount > Single Output section. Power-One’s hot-swap products combine high-efficiency topologieswith advanced thermal management techniques to provide
industry-leading power densities. Additional features include:• Extensive I2C interface monitoring & control capabilities• Active current share with ORing FETs• Compact, low-profile packages that fit 1U-height constraints
Chassis-mount front ends are listed in the Chassis Mount > Single-Output section
Backplane-Mounted Input Connector - AC-DC
Front-Mounted Input Receptacle - AC-DC & DC-DC
NominalVout
MaxAmps
VinRange
Vout TrimRange
StandbyVout
PowerSupply
MatingShelves
12V125 85 to 264 VAC N/A 12V FXP1500-12 FXR-3-12
400 380 to 498 VAC N/A N/A FE5A-1D-0 N/A
15V 330 380 to 498 VAC N/A N/A FE5A-1E-0 N/A
24V 208 380 to 498 VAC N/A N/A FE5A-1F-0 N/A
28V 180 380 to 498 VAC N/A N/A FE5A-1G-0 N/A
32V 175 180 to 264 or 342 to 528 VAC
30.5 to 33.5 12V FXP6000-32-S FRH7000 &FRV7000
36V 140 380 to 498 VAC N/A N/A FE5A-1H-0 N/A
48V
31 85 to 264 VAC 44.2 to 51.8 12V FXP1500-48 FXR-3-48
37.5 85 to 264 VAC 44.2 to 51.8 12V FXP1800-48 FXR-3-48
104 380 to 498 VAC N/A N/A FE5A-1J-0 N/A
125 180 to 264 or342 to 528 VAC
45.6 to 50.4 12V FXP6000-48-S FRH7000 &FRV7000
145 180 to 264 or342 to 528 VAC
45.6 to 50.4 12V FXP7000-48-S FRH7000 &FRV7000
NominalVout
MaxAmps
VinRange
Vout TrimRange
StandbyVout
PowerSupply
MatingShelves
12V
25 85 to 264 VAC N/A 12V FNP300-1012 N/A
36.6 90 to 264 VAC N/A 3.3V SFP450-12 N/A
45 -40 to -75 VDC N/A 3.3V SFD550-12B N/A
50 90 to 264 VAC 7 to 12 12V FNP600-12 FNR-5-12
53.3 90 to 264 VAC N/A 3.3V SFP650-12 N/A
73 90 to 264 VAC 7 to 12 12V FNP850-12 FNR-5-12
125 85 to 264 VAC 7 to 13 12V FNP1500-12 FNR-3-12
24V 12.5 85 to 264 VAC N/A 12V FNP300-1024 N/A
48V
6.2 85 to 264 VAC N/A 12V FNP300-1048 N/A
12.5 90 to 264 VAC N/A 12V FNP600-48 FNR-5-48
13 85 to 264 VAC N/A 3.3V FCP600-48 N/A
21 90 to 264 VAC N/A 12V FNP1000-48 FNR-5-48
31 85 to 264 VAC 44.2 to 51.8 12V FNP1500-48 FNR-3-48
37.5 85 to 264 VAC 44.2 to 51.8 12V FNP1800-48 FNR-3-48
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Hot Swap Front Ends > Single Output
5
VoutNominal
MaxAmps
InputRange Shelf Height Width Depth
PowerSupply
Max # ofSupplies
12V
250 85 to 264 VAC FNR-5-12 1U 19” 13” FNP600-12 5
355 85 to 264 VAC FNR-5-12 1U 19” 13” FNP850-12 5
375 85 to 264 VAC FNR-3-12 1U 19” 13” FNP1500-12 3
375 85 to 264 VAC FXR-3-12 1U 19” 14” FXP1500-12 3
32V
350 180 to 264 or342 to 528 VAC
FRH7000 3U 17.5” 24” FXP6000-32-S 2
525 180 to 264 or342 to 528 VAC
FRV7000 5U 17.5” 24” FXP6000-32-S 3
48V
62 85 to 264 VAC FNR-5-48 1U 19” 13” FNP600-48 5
93 85 to 264 VAC FNR-3-48 1U 19” 13” FNP1500-48 3
93 85 to 264 VAC FXR-3-48 1U 19” 14” FXP1500-48 3
105 85 to 264 VAC FNR-5-48 1U 19” 13” FNP1000-48 5
112 85 to 264 VAC FNR-3-48 1U 19” 13” FNP1800-48 3
112 85 to 264 VAC FXR-3-48 1U 19” 14” FXP1800-48 3
250 180 to 264 or342 to 528 VAC
FRH7000 3U 17.5” 24” FXP6000-48-S 2
290 180 to 264 or342 to 528 VAC
FRH7000 3U 17.5” 24” FXP7000-48-S 2
375 180 to 264 or342 to 528 VAC
FRV7000 5U 17.5” 24” FXP6000-48-S 3
435 180 to 264 or342 to 528 VAC
FRV7000 5U 17.5” 24” FXP7000-48-S 3
AC-DC Power Shelves• Up to 525 Amps per shelf configuration• Shelves may be partially populated for reduced
currents, or paralleled for higher currents.
The FNP1500-12G combines 90% efficiency with a 125-amp outputthat is I2C programmable from 7-13 VDC.• I2C-interface capabilities include enabling the output, controlling
internal fan speed, and setting the output current limit.• Wide output adjustment range facilitates bus-voltage optimization,
minimizing system-specific I2R distribution losses, and increasingthe efficiencies of bricks and POL converters.
• For further details regarding bus-voltage optimization, please referto the “Reducing IBA Power Dissipation and Consumption withAdaptive/Intelligent Control and Power Management” articlesummary on page 80.
AC-DC Front-End Reduces Power Consumptionin Server, Telecom, and Datacom Applications
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Hot-Swap Front Ends > Multiple-Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
6
HP6 Multi-Output AC-DC Front End
HP600 Rack
HP6 and RACK-HP600• Compact 1U design • N+1 redundancy with hot-plug capability• Up to four individually-regulated outputs
• I2C interface with interrupt capability• Hot-swap with low insertion/extraction force
connector• Power factor corrected• No minimum load required• 5 V @ 1 A standby output• Single-wire current sharing• Self-contained ORing diodes• Current limit and overvoltage protection• Full power up to 50 ºC• TUV, cTUVus, & CB report• 600 Watts per module• AC input with PFC
The HP6 provides up to 600 watts of total output power with one to four outputs ranging from 0.8 to 12 VDC. HP600 Racks offerhot-plug capability for up to 1200 watts total at low line (2 +1) or 1800 watts total at high line. Three separate multi-output powersupplies are internally paralleled and will automatically current share for load distribution. Hot-swap modules can be replaced withno system downtime.
V1 V2 V3 V4HP6 Front End Models Volts Amps Volts Amps Volts Amps Volts Amps
HP6-X8X8D2D-0 X 80 X 80 12 20 -12 3HP6-X4X8D4D-0 X 80 X 80 12 20 -12 3HP6-X8X4D4D-0 X 80 X 80 12 20 -12 3HP6-X8X4D2D-0 X 80 X 80 12 20 -12 3HP6-X4X8D2D-0 X 80 X 80 12 20 -12 3HP6-X4X4D4D-0 X 80 X 80 12 20 -12 3
RACK-HP600 DesignationsRACK-HP600 X 240 X 120 12 120 -12 9
To configure a power solution, substitute the X’s in the above table with one of the output voltages listed below:A (2.0V); B (3.3V); C (5V); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V)Options O = B (I2C); M (Output power good - TTL high); N (Power fail - TTL high); R (Reverse airflow)
Visit www.power-one.com for informationon backplane AC-input HP600 front ends.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > SMT > Single-Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
7
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
Nominal 24Vin18 to 36 1.2 1.1 to 1.3 15 SQ24S15012
18 to 36 1.5 1.2 to 1.6 15 SQ24S15015
18 to 36 1.8 1.5 to 1.9 15 SQ24S15018
18 to 36 2 1.6 to 2.2 15 SQ24S15020
18 to 36 2.5 2 to 2.7 15 SQ24S15025
18 to 36 3.3 2.7 to 3.6 15 SQ24S15033
18 to 36 5 4 to 5.5 10 SQ24S10050
18 to 36 6 4.8 to 6.6 8 SQ24S08060
18 to 36 8 6.4 to 8.8 5.3 SQ24S05080
18 to 36 12 9.6 to 13.2 4 SQ24S04120
19 to 36 15 12 to 16.5 3.3 SQ24S03150
Nominal 48Vin36 to 75 1.2 1.1 to 1.3 15 SQ48S15012
36 to 75 1.2 1.1 to 1.3 25 SQM48S25012
36 to 75 1.5 1.2 to 1.6 15 SQ48S15015
36 to 75 1.5 1.2 to 1.6 20 SQM48S20015
36 to 75 1.5 1.2 to 1.6 25 SQM48S25015
36 to 75 1.8 1.5 to 1.9 15 SQ48S15018
36 to 75 1.8 1.5 to 1.9 20 SQM48S20018
36 to 75 1.8 1.5 to 1.9 25 SQM48S25018
36 to 75 2 1.6 to 2.2 15 SQ48S15020
36 to 75 2.5 2 to 2.7 15 SQ48S15025
36 to 75 2.5 2 to 2.7 20 SQM48S20025
36 to 75 2.5 2 to 2.7 25 SQM48S25025
36 to 75 3.3 2.7 to 3.6 15 SQ48S15033
36 to 75 3.3 2.7 to 3.6 20 SQM48S20033
36 to 75 5 4 to 5.5 10 SQ48S10050
36 to 75 6 4.8 to 6.6 8 SQ48S08060
36 to 75 8 8.4 to 8.8 5.3 SQ48S05080
36 to 75 12 9.6 to 13.2 4 SQ48S04120
SMT > Single-Output > 1/8 Brick
SQ24S2.30 x 0.90 x 0.26 inch58.4 x 22.8 x 6.6 mm
SQ48S2.30 x 0.90 x 0.26 inch58.4 x 22.8 x 6.6 mm
SQM48S2.30 x 0.90 x 0.28 inch58.4 x 22.8 x 7.1 mm
• 24 to 66 Watts (Up to 25 A)• Industry-Standard Surface
Mount, Quarter-Brick Pinout• High Efficiency (No Heat Sink
Required)
• 15 to 50 Watts (Up to 15 A)• Industry-Standard Surface
Mount, Quarter-Brick Pinout• Low Profile: 0.26" (6.6 mm)• High Efficiency (No Heat Sink
Required)
• Delivers Up to 15 A (50 W)• Industry-Standard Surface
Mount, Quarter-Brick Pinout• Low Profile: 0.26" (6.6mm)• No Minimum Load
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > SMT > Single-Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
8
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
Nominal 24Vin
18 to 36 1.5 1.2 to 1.6 25 Q24S25015
18 to 36 1.5 1.2 to 1.6 30 Q24S30015
18 to 36 1.8 1.5 to 1.9 25 Q24S25018
18 to 36 1.8 1.5 to 1.9 30 Q24S30018
18 to 36 2.5 2 to 2.7 25 Q24S25025
18 to 36 2.5 2 to 2.7 30 Q24S30025
18 to 36 3.3 2.7 to 3.6 25 Q24S25033
18 to 36 3.3 2.7 to 3.6 30 Q24S30033
18 to 36 5 4 to 5.5 15 Q24S15050
Nominal 48Vin36 to 75 1.2 1.1 to 1.3 30 QL48S30012
36 to 75 1.5 1.2 to 1.6 25 Q48S25015
36 to 75 1.5 1.2 to 1.6 30 Q48S30015
36 to 75 1.8 1.5 to 1.9 25 Q48S25018
36 to 75 1.8 1.5 to 1.9 30 Q48S30018
36 to 75 1.8 1.5 to 1.9 40 QM48S40018
36 to 75 2 1.6 to 2.2 25 Q48S25020
36 to 75 2 1.6 to 2.2 30 Q48S30020
36 to 75 2.5 2 to 2.7 25 Q48S25025
36 to 75 2.5 2 to 2.7 30 Q48S30025
36 to 75 3.3 2.7 to 3.6 25 Q48S25033
36 to 75 3.3 2.7 to 3.6 30 Q48S30033
36 to 75 3.3 2.7 to 3.6 40 QM48S40033
36 to 75 5 4 to 5.5 15 Q48S15050
36 to 75 5 4 to 5.5 20 Q48S20050
36 to 75 5 4 to 5.5 25 QM48S25050
36 to 75 12 9.6 to 13.2 8 Q48S08120
36 to 75 12 9.6 to 13.2 14 QM48S14120
QM48S
QL48S
Q24S & Q48S
• 24 to 36 Watts (Down to 0.8 V)
• Industry-Standard SurfaceMount, Quarter-Brick Pinout
• Low Profile: 0.26" (6.6 mm)• High Efficiency (No Heat Sink
Required)
• Delivers Up to 40 A (132 W)• Industry-Standard Surface
Mount, Quarter-Brick Pinout• Low Profile: 0.28”• High Efficiency (No Heat Sink
Required)• Remote Output Sense
2.30 x 1.45 x 0.26 inch58.4 x 36.8 x 6.6 mm
2.30 x 1.45 x 0.28 inch58.4 x 36.8 x 7.1 mm
2.30 x 1.45 x 0.26 inch58.4 x 36.8 x 6.6 mm
• 24 to 100 Watts (Up to 30 A)• Industry-Standard Surface
Mount, Quarter-Brick Pinout• Low Profile: 0.26" (6.6 mm)• High Efficiency (No Heat Sink
Required)
SMT > Single-Output > 1/4 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > SMT > Single-Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
9
1.30 x 0.81 x 0.33 inch33 x 20.6 x 8.5 mm
• 4 to 10 Watts• Single Outputs, 1.5 to 5 VDC• Remote On/Off
1.30 x 0.91 x 0.33 inch33 x 23 x 8.5 mm
• 4 to 6 Watts• Single/Dual Outputs• Operation from -40 to 85 °C
NDS
NVS
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
9 to 36Vin
9 to 36 3.3 3.3 0.9 NVS0.9CE-M6
9 to 36 5 5 0.7 NVS0.7CG-M6
9 to 36 12 12 0.3 NVS0.3CH-M6
9 to 36 15 15 0.3 NVS0.3CJ-M6
18 to 36Vin18 to 36 5 5 1 NVS01YG-M6
18 to 36 12 12 0.5 NVS0.5YH-M6
18 to 36 15 15 0.4 NVS0.4YJ-M6
Ultra-Wide Input18 to 75 3.3 3.3 0.9 NVS0.9EE-M6
18 to 72 3.3 2.7 to 3.8 1.5 RNS01EE-M6
18 to 75 5 5 0.7 NVS0.7EG-M6
18 to 72 5.1 4.3 to 5.9 1.2 RNS01EG-M6
18 to 72 7 6 to 8 0.9 RNS0.9ET-M6
18 to 75 12 12 0.3 NVS0.3EH-M6
18 to 75 15 15 0.3 NVS0.3EJ-M6
Nominal 48Vin, 1.5 to 2.5Vout36 to 75 1.5 1.4 to 1.6 3 NDS03ZA-M6
36 to 75 1.5 1.4 to 1.7 6 RFS06ZA-M6
36 to 75 1.8 1.7 to 1.9 3 NDS03ZB-M6
36 to 75 1.8 1.6 to 1.9 6 RFS06ZB-M6
36 to 75 2.5 2.3 to 2.7 3 NDS03ZD-M6
36 to 75 2.5 2.3 to 2.7 6 RFS06ZD-M6
Nominal 48Vin, 3.3 to 15Vout36 to 75 3.3 3 to 3.6 3 NDS03ZE-M6
38 to 75 3.3 2.3 to 4 3 RNS03ZE-M6
36 to 75 3.3 3 to 3.6 5 RDS05ZE-M6
36 to 75 3.3 2.9 to 3.6 6 RFS06ZE-M6
36 to 72 3.3 3 to 3.6 13 SFS13ZE-M6
36 to 75 5 5 1 NVS01ZG-M6
36 to 75 5 4.5 to 5.5 2 NDS02ZG-M6
36 to 75 5 4.5 to 5.5 4 RDS04ZG-M6
36 to 75 5 4.5 to 5.5 4 RFS04ZG-M6
36 to 72 5 4.5 to 5.5 8 SFS08ZG-M6
38 to 75 5.1 4 to 6 2 RNS02ZG-M6
36 to 75 12 12 0.5 NVS0.5ZH-M6
38 to 75 12 9 to 15 0.6 RNS0.6ZH-M6
36 to 75 15 15 0.4 NVS0.4ZJ-M6
2.00 x 1.28 x 0.32 inch50.8 x 32.5 x 8.2 mm
SFS
1.87 x 1.00 x 0.33 inch47.4 x 25.4 x 8.4 mm
• 10 to 20 Watts• 1500 VDC Isolation• Operation to 85 °C
1.87 x 1.00 x 0.37 inch47.4 x 25.4 x 9.5 mm
• 9 to 20 Watts• Single Outputs, 1.5 to 5 VDC• 1500 VDC Isolation• Remote On/Off
1.87 x 1.00 x 0.34 inch47.4 x 25.4 x 8.5 mm
RNS
RDS
RFS
SMT > Single-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > SMT > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
10
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Nominal 48Vin36 to 75 +1.2 1.1 to 1.3, 15 41 QD48S012015
+1.5 1.4 to 1.7 15
36 to 75 +1.2 1.1 to 1.3 15 56 QD48S012025
+2.5 2.3 to 2.8 15
36 to 75 +1.2 1.1 to 1.3 15 68 QD48S012033
+3.3 3 to 3.6 15
36 to 75 +1.5 1.4 to 1.7 15 50 QD48S015018
+1.8 1.6 to 2 15
36 to 75 +1.5 1.4 to 1.7 15 60 QD48S015025
+2.5 2.3 to 2.8 15
36 to 75 +1.5 1.4 to 1.7 15 72 QD48S015033
+3.3 3 to 3.6 15
36 to 75 +1.5 1.4 to 1.7 15 73 QD48S015050
+5 4.5 to 5.5 10
36 to 75 +1.8 1.6 to 2 15 65 QD48S018025
+2.5 2.3 to 2.8 15
36 to 75 +1.8 1.6 to 2 15 77 QD48S018033
+3.3 3 to 3.6 15
36 to 75 +1.8 1.6 to 2 15 77 QD48S018050
+5 4.5 to 5.5 10
36 to 75 +2.5 2.3 to 2.8 15 87 QD48S025033
+3.3 3 to 3.6 15
36 to 75 +3.3 3 to 3.6 15 100 QD48S033050
+5 4.5 to 5.5 10
2.30 x 1.45 x 0.26 inch58.4 x 36.8 x 6.6 mm
QD48S
• Independently-RegulatedOutputs
• Minimal Cross-ChannelInterference
• Startup into Pre-biasedOutputs
• Industry-Standard Footprint& Pinout
SMT > Dual-Output > 1/4 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > SMT > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
11
NVD1.30 x 0.81 x 0.33 inch33.0 x 20.6 x 8.5 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
9 to 36Vin9 to 36 +5 N/A 0.3 3.5 NVD0.7CGG-M6
-5 N/A 0.39 to 36 +12 N/A 0.2 4 NVD0.3CHH-M6
-12 N/A 0.29 to 36 +15 N/A 0.1 4.2 NVD0.3CJJ-M6
-15 N/A 0.19 to 36 +24 N/A 0.1 3.8 NVD0.2CKK-M6
-24 N/A 0.1
18 to 36Vin18 to 36 +5 N/A 0.5 5 NVD01YGG-M6
-5 N/A 0.518 to 36 +12 N/A 0.2 6 NVD0.5YHH-M6
-12 N/A 0.218 to 36 +15 N/A 0.2 6 NVD0.4YJJ-M6
-15 N/A 0.2
Ultra-Wide Input18 to 75 +5 N/A 0.3 3.5 NVD0.7EGG-M6
-5 N/A 0.318 to 75 +12 N/A 0.2 4 NVD0.3EHH-M6
-12 N/A 0.218 to 75 +15 N/A 0.1 4.2 NVD0.3EJJ-M6
-15 N/A 0.118 to 75 +24 N/A 0.1 3.8 NVD0.2EKK-M6
-24 N/A 0.1
Nominal 48Vin38 to 75 +3.3 2.8 to 3.8 1 8.5 RND02ZGE-M6
+5.2 4.4 to 5.9 136 to 75 +5 N/A 0.5 5 NVD01ZGG-M6
-5 N/A 0.538 to 75 +5.1 4 to 7 1 10.2 RND02ZGG-M6
-5.1 4 to 7 136 to 75 +12 N/A 0.2 6 NVD0.5ZHH-M6
-12 N/A 0.238 to 75 +12 9 to 15 0.4 10 RND0.8ZHH-M6
-12 9 to 15 0.436 to 75 +15 N/A 0.2 6 NVD0.4ZJJ-M6
-15 N/A 0.2
RND1.87 x 1.00 x 0.34 inch47.4 x 25.4 x 8.5 mm
SMT > Input Filters
Max Max Input MeetsAmps Voltage Mounting Conducted Part Number4 80 SMT FCC Class B F4804A
10 50 SMT FCC Class B F2410
10 100 SMT FCC Class B F4810
SMT > Dual-Output > Non-Brick
• Basic Insulation• Low-profile SMT design• 1500 VDC input-to-output
isolation
• Basic Insulation• Low conducted and radiated
EMI• Wide output trim adjust
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
12
Brick Input Factory Output Vout MaxSize Voltage Set Vout Trim Range Regulation Amps Model1/8 38 to 55 9.6 6.7 to 11 Fixed ratio 5:1 line 27 SQT48T27096
1/8 38 to 55 9.6 7 to 11 Fixed ratio 5:1 line 38 SQT48T38096
1/8 38 to 55 12 8.7 to 13.7 Fixed ratio 4:1 line 20 SQT48T20120
1/4 18 to 60 12 11 to 13 4% line/load/temp 6.7 QMS07DH
1/4 36 to 55 9.6 7.2 to 11 Fixed ratio 5:1 line 38 QTS48T38096
1/4 36 to 55 9.6 7.2 to 11 Fixed ratio 5:1 line 46 QTS48T46096
1/4 36 to 75 12 9.6 to 13.2 5% line/load/temp 11 QBC11ZH
1/4 36 to 75 12 9.6 to 13.2 2% line/load/temp 20 QME48T20120
1/4 36 to 75 12 N/A 1% line/1% load/3% temp 21 QKS48T21120
1/4 42 to 53 12 10.5 to 13.3 Fixed ratio 4:1 line 25 QTS48T25120
1/2 36 to 75 12 9.6 to 13.2 4% line/load/temp 25 HBC25ZH
1/2 36 to 75 12 9.6 to 13.2 2% line/load/temp 25 HBC48T25120
1/2 36 to 75 12 10.8 to 13.2 3% line/load/temp 30 HDS48T30120
1/2 35 to 75 12 10.8 to 13.2 4% line/load/temp 32 HKS48T30120
Full 36 to 75 12 10.8 to 13.2 4% line/load/temp 42 FBC42ZH
This optimized bus converter can provide 210 watts at 70 °C with200 LFM airflow.• Complies with Basic Insulation Requirements of EN60950• Protections Include Output Overvoltage and Overcurrent,
Overtemperature, and Input Undervoltage Lockout • Onboard Input-Differential LC Filter
SQT is 96% Efficient and Provides 300 W/in3
The 32-amp HKS48T30120 provides minimal-power-deratedoperation in elevated temperature environments.• 2121 VDC Input-to-Output Isolation• Remote On/Off, Sense, and Output Trim• Protections Include Output Overvoltage and Overcurrent,
Overtemperature, and Input Undervoltage Lockout
HKS Provides Full Regulation and Efficiencies up to 94.5%
The QTS incorporates a low-component-count 4:1 proportional ratiotopology that reduces cost and increases reliability.• 2000 VDC Input-to-Output Isolation• 258 Watts Available at 70 °C with 200 LFM Cooling• Low Conducted and Radiated EMI• Start-up into High Capacitive Load
96% Efficient QTS Provides 300 Watts
HHS04 & HHS052.40 x 2.28 x 0.42 inch61.0 x 57.9 x 10.7 mm
FBC
HBC, HDS, & HKS
4.60 x 2.40 x 0.50 inch116.8 x 61.0 x 12.7 mm
2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
HBC48T2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
QBC2.28 x 1.45 x 0.43 inch57.9 x 36.8 x 11 mm
QKS2.28 x 1.45 x 0.50 inch57.9 x 36.8 x 12.7 mm
Thru-Hole > Single-Output > Bus Converters
Additional single-output products are listed in the surface-mount and through-hole isolated DC-DC sections.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
13
Alpha-sorted graphics anddimensions augment modellistings from both pages.
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
36 to 75 52.5 50 to 53 3.8 HHS04Z52
36 to 75 53.7 51.2 to 54.2 4.8 HHS05Z55
The HHS04Z52 and HHS05Z55 are designed specifically forPower-over-Ethernet applications and meet the requirements ofIEEE802.3af.• Fully-Regulated Outputs• 2250 VDC Input-to-Output Isolation• Remote Sense, Remote Trim, and Primary Referenced On/Off• Protections Include Output Overvoltage and Overcurrent,
Overtemperature, and Input Undervoltage Lockout
Power-over-Ethernet HHS04 & HHS05 Half-Bricks
The SSQE has an industry-standard, DOSA-compliant package anddelivers up to 66 watts of power.• Isolated Output (Basic Insulation per EN60950)• Remote Sense, Remote Trim, and Primary Referenced On/Off• Protections Include Output Overvoltage and Overcurrent,
Overtemperature, and Input Undervoltage Lockout• Monotonic Start-up into Pre-biased Output
SSQE 1/16th-Brick
Thru-Hole > Single-Output > 1/16-Brick
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model36 to 75 2.5 2 to 2.7 25 SSQE48T25025
36 to 75 3.3 2.6 to 3.6 20 SSQE48T20033
QTS48T38, QTS48T46
QTS48T25
2.28 x 1.45 x 0.50 inch57.9 x 36.8 x 12.7 mm
2.28 x 1.45 x 0.40 inch57.9 x 36.8 x 10.2 mm
QMS2.28 x 1.45 x 0.5 inch57.9 x 36.8 x 12.7 mm
SQT48T202.30 x 0.9 x 0.39 inch58.4 x 22.8 x 10 mm
• Fixed-Ratio Topology• High Efficiencies and
Current Densities
SQT48T27 & SQT48T382.30 x 0.90 x 0.48 inch58.4 x 22.8 x 12.1 mm
SSQE48T1.3 x 0.9 x 0.4/0.374 inch33 x 22.9 x 10.2/9.5 mm
Thru-Hole > Single-Output > Power Over Ethernet
QME48T2.30 x 1.45 x 0.48 inch58.4 x 36.8 x 12.2 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
14
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
18 to 36Vin18 to 36 1 0.9 to 1.1 15 SQ24T15010
18 to 36 1.2 1.1 to 1.3 15 SQ24T15012
18 to 36 1.5 1.2 to 1.6 15 SQ24T15015
18 to 36 1.8 1.5 to 1.9 15 SQ24T15018
18 to 36 2 1.6 to 2.2 15 SQ24T15020
18 to 36 2.5 2 to 2.7 15 SQ24T15025
18 to 36 3.3 2.7 to 3.6 15 SQ24T15033
18 to 36 5 4 to 5.5 10 SQ24T10050
18 to 36 6 4.8 to 6.6 8 SQ24T08060
18 to 36 8 6.4 to 8.8 5.3 SQ24T05080
18 to 36 12 9.6 to 13.2 4 SQ24T04120
19 to 36 15 12 to 16.5 3.3 SQ24T03150
Ultra-Wide Input18 to 60 3.3 2.5 to 3.6 15 EMS15DE
18 to 60 5 4.5 to 6 10 EMS10DG
Nominal 48Vin36 to 75 1 0.9 to 1.1 15 SQ48T15010
36 to 75 1.2 1.1 to 1.3 15 SQ48T15012
36 to 75 1.2 1.1 to 1.3 30 SQE48T30012
36 to 75 1.2 1.1 to 1.3 50 SQE48T50012
36 to 75 1.5 1.2 to 1.6 15 SQ48T15015
36 to 75 1.5 1.2 to 1.6 30 SQE48T30015
36 to 75 1.8 1.5 to 1.9 15 SQ48T15018
36 to 75 1.8 1.5 to 1.9 30 SQE48T30018
36 to 75 1.8 1.5 to 1.9 40 SQE48T40018
36 to 75 2 1.6 to 2.2 15 SQ48T15020
36 to 75 2.5 2 to 2.7 15 SQ48T15025
36 to 75 2.5 2 to 2.7 25 SQE48T40025
36 to 75 2.5 2 to 2.7 30 SQE48T30025
36 to 75 3.3 2.7 to 3.6 15 SQ48T15033
36 to 75 3.3 2.7 to 3.6 20 SQE48T20033
36 to 75 3.3 2.7 to 3.6 30 SQE48T30033
36 to 75 5 4 to 5.5 10 SQ48T10050
36 to 75 5 4 to 5.5 20 SQE48T20050
36 to 75 6 4.8 to 6.6 8 SQ48T08060
36 to 75 6 4.8 to 6.6 17 SQE48T17060
36 to 75 8 6.4 to 8.8 5.3 SQ48T05080
36 to 75 12 9.6 to 13.2 4 SQ48T04120
38 to 55 9.6 6.7 to 11 27 SQT48T27096 *
38 to 55 9.6 7 to 11 38 SQT48T38096 *
38 to 55 12 8.7 to 13.7 20 SQT48T20120 *
* Fixed-ratio input-to-output voltage
Q24T & Q48T2.30 x 1.45 x 0.28 inch58.4 x 36.8 x 7.1 mm
QES2.30 x 1.45 x 0.34 inch58.4 x 36.8 x 8.5 mm
QHS2.30 x 1.45 x 0.50 inch58.4 x 36.8 x 12.7 mm
QL48T2.30 x 1.45 x 0.28 inch58.4 x 36.8 x 7.1 mm
EMS2.30 x 0.9 x 0.43 inch58.4 x 22.9 x 10.8 mm
QLS302.28 x 1.45 x 0.43 inch57.9 x 36.8 x 11 mm
Thru-Hole > Single-Output > 1/8 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
15
Alpha-sorted graphics anddimensions augment modellistings from both pages.
SQT48T202.30 x 0.90 x 0.39 inch58.4 x 22.8 x 10 mm
SQT48T27 & SQT48T382.30 x 0.90 x 0.48 inch58.4 x 22.8 x 12.1 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
18 to 36Vin18 to 36 1.5 1.2 to 1.6 25 Q24T25015
18 to 36 1.5 1.2 to 1.6 30 Q24T30015
18 to 36 1.8 1.5 to 1.9 25 Q24T25018
18 to 36 1.8 1.5 to 1.9 30 Q24T30018
18 to 36 2 1.6 to 2.2 25 Q24T25020
18 to 36 2 1.6 to 2.2 30 Q24T30020
18 to 36 2.5 2 to 2.7 25 Q24T25025
18 to 36 2.5 2 to 2.7 30 Q24T30025
18 to 36 3.3 3 to 3.6 15 QES050YE-A
18 to 36 3.3 2.7 to 3.6 25 Q24T25033
18 to 36 3.3 2.7 to 3.6 30 Q24T30033
18 to 36 5 4 to 5.5 15 Q24T15050
Ultra-Wide Input18 to 60 3.3 3 to 3.6 25 QMS25DE
18 to 60 5 4.5 to 6 14 QMS14DG
18 to 60 12 11 to 13 6.75 QMS07DH
Nominal 48Vin36 to 75 1.2 1.1 to 1.3 30 QL48T30012
36 to 75 1.2 1.1 to 1.3 30 QLS30ZY
36 to 75 1.2 1.1 to 1.3 40 QM48T40012
36 to 75 1.2 1.1 to 1.3 40 QME48T40012
36 to 75 1.2 1.1 to 1.3 45 QM48T45012
36 to 75 1.2 1.1 to 1.3 50 QM48T50012
36 to 75 1.5 1.2 to 1.6 25 Q48T25015
36 to 75 1.5 1.2 to 1.6 30 Q48T30015
36 to 75 1.5 1.4 to 1.6 30 QLS30ZA
36 to 75 1.5 1.2 to 1.6 40 QME48T40015
36 to 75 1.5 1.4 to 1.6 40 QM48T40015
36 to 75 1.5 1.2 to 1.6 45 QM48T45015
36 to 75 1.5 1.2 to 1.6 50 QM48T50015
36 to 75 1.5 1.4 to 1.7 50 QHS50ZA
36 to 75 1.8 1.5 to 1.9 25 Q48T25018
36 to 75 1.8 1.5 to 1.9 30 Q48T30018
36 to 75 1.8 1.7 to 1.9 30 QLS30ZB
36 to 75 1.8 1.4 to 2 40 QME48T40018
36 to 75 1.8 1.6 to 2 40 QHS40ZB
36 to 75 1.8 1.7 to 1.9 40 QM48T40018
36 to 75 1.8 1.5 to 1.9 45 QM48T45018
36 to 75 1.8 1.5 to 1.9 50 QM48T50018
Continued on Next Page
QM48T2.30 x 1.45 x 0.31 inch58.4 x 36.8 x 7.8 mm
QMS2.28 x 1.45 x 0.5 inch57.9 x 36.8 x 12.7 mm
QME48T2.30 x 1.45 x 0.48 inch58.4 x 36.8 x 12.2 mm
Thru-Hole > Single-Output > 1/4 Brick
SQ24T & SQ48T2.30 x 0.90 x 0.28 inch58.4 x 22.8 x 7.1 mm
SQE48T2.30 x 0.90 x 0.41 inch58.4 x 22.8 x 10.3 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
16
QLSFor QLS15 Model
2.28 x 1.45 x 0.39 inch57.9 x 36.8 x 9.9 mm
For QLS30 Models2.28 x 1.45 x 0.43 inch57.9 x 36.8 x 11 mm
QTS Series2.28 x 1.45 x 0.40 inch57.9 x 36.8 x 10.2 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
Nominal 48Vin (Continued)36 to 75 2 1.6 to 2.2 25 Q48T25020
36 to 75 2 1.6 to 2.2 30 Q48T30020
36 to 75 2 1.8 to 2.2 40 QM48T40020
36 to 75 2 1.6 to 2.2 45 QM48T45020
36 to 75 2.5 2 to 2.7 25 Q48T25025
36 to 75 2.5 2.3 to 2.7 25 QLS25ZD
36 to 75 2.5 2 to 2.7 30 Q48T30025
36 to 75 2.5 2 to 2.7 40 QME48T40025
36 to 75 2.5 2.3 to 2.7 40 QM48T40025
36 to 75 2.5 2 to 2.7 45 QM48T45025
36 to 75 3.3 3 to 3.6 15 QLS15ZE
36 to 75 3.3 3 to 3.6 15 QES050ZE-A
36 to 75 3.3 3 to 3.6 20 QES066ZE-A
36 to 75 3.3 2.7 to 3.6 25 Q48T25033
36 to 75 3.3 3 to 3.6 25 QLS25ZE
36 to 75 3.3 2.7 to 3.6 30 Q48T30033
36 to 75 3.3 2.7 to 3.6 40 QME48T40033
36 to 75 3.3 2.7 to 3.6 40 QM48T40033
36 to 75 3.3 3 to 3.6 40 QHS40ZE
36 to 75 3.3 2.7 to 3.6 45 QM48T45033
36 to 75 5 4.5 to 5.5 12 QLS12ZG
36 to 75 5 4.5 to 5.5 15 Q48T15050
36 to 75 5 4.5 to 5.5 20 QLS20ZG
36 to 75 5 4 to 5.5 20 Q48T20050
36 to 75 5 4 to 5.5 25 QM48T25050
36 to 75 5 4.5 to 5.5 25 QHS25ZG
36 to 75 5 4 to 5.5 40 QME48T40050
36 to 55 9.6 7.2 to 11 38 QTS48T38096*
36 to 55 9.6 7.2 to 11 46 QTS48T46096*
36 to 75 12 9.6 to 13.2 8 Q48T08120
36 to 75 12 9.6 to 13.2 11 QBC11ZH
36 to 75 12 10.8 to 13.2 12 QHS12ZH
36 to 75 12 9.6 to 13.2 14 QM48T14120
36 to 75 12 9.6 to 13.2 20 QME48T20120
36 to 75 12 N/A 21 QKS48T21120
42 to 53 12 10.5 to 13.3 25 QTS48T25120*
* Fixed-ratio input-to-output voltage
QBC2.28 x 1.45 x 0.43 inch57.9 x 36.8 x 11 mm
QKS2.30 x 1.45 x 0.50 inch58.4 x 36.8 x 12.7 mm
Q48T2.30 x 1.45 x 0.28 inch58.4 x 36.8 x 7.1 mm
QME48T2.30 x 1.45 x 0.48 inch58.4 x 36.8 x 12.2 mm
QHS2.30 x 1.45 x 0.50 inch58.4 x 36.8 x 12.7 mm
QES2.30 x 1.45 x 0.34 inch58.4 x 36.8 x 8.5 mm
QM48T2.30 x 1.45 x 0.31 inch58.4 x 36.8 x 7.8 mm
Thru-Hole > Single-Output > 1/4 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
17
HAS, HBC, & HBS
2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
HDS2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
HHS40 & HHS602.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
HKS2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
HHS04 & HHS052.40 x 2.28 x 0.42 inch61.0 x 57.9 x 10.7 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
18 to 36Vin18 to 36 12 10.8 to 13.2 2.5 HBS030YH-A
18 to 36 12 10.8 to 13.2 8.3 HBS100YH-A
Nominal 48Vin36 to 75 1.8 1.6 to 2 60 HHS60ZB
36 to 75 3.3 3 to 3.6 40 HHS40ZE
36 to 75 3.3 3 to 3.6 60 HHS60ZE
36 to 75 5 4.5 to 5.5 6 HAS030ZG-A
36 to 75 12 10.8 to 13.2 2.5 HAS030ZH-A
36 to 75 12 9.6 to 13.2 25 HBC25ZH
36 to 75 12 10.8 to 13.2 25 HBC48T25120
36 to 75 12 10.8 to 13.2 30 HDS48T30120
36 to 75 12 10.8 to 13.2 32 HKS48T30120
36 to 75 52.5 50 to 53 3.8 HHS04Z52
36 to 75 53.7 51.2 to 54.2 4.8 HHS05Z55
The HHS04Z52 and HHS05Z55 are designed specifically forPower-over-Ethernet applications and meet the requirements ofIEEE802.3af.• Fully-Regulated Outputs• 2250 VDC Input-to-Output Isolation• Remote Sense, Remote Trim, and Primary Referenced On/Off• Protections Include Output Overvoltage and Overcurrent,
Overtemperature, and Input Undervoltage Lockout
Power-over-Ethernet Half-Bricks
The 32-amp HKS48T30120 utilizes advanced thermal-managementtechniques to facilitate minimal-power-derated operation in elevatedtemperature environments.• 2121 VDC Input-to-Output Isolation• Remote On/Off, Sense, and Output Trim• Protections Include Output Overvoltage and Overcurrent,
Overtemperature, and Input Undervoltage Lockout
HKS Provides Full Regulation and Efficiencies up to 94.5%
Thru-Hole > Single-Output > 1/2 Brick
HBC48T2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
18
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
3.3Vout
3.3 N/A 8.4 to 36 0.9 20IMX4-03-8
3.3 N/A 16.8 to 75 0.9 40IMX4-03-8
3.3 2.5 to 3.5 8 to 36 1.5 20IMX7-03-8
3.3 2.5 to 3.5 16.8 to 75 1.5 40IMX7-03-8
3.3 2.5 to 3.5 40 to 121 1.5 70IMX7-03-8
3.3 3 to 3.6 36 to 72 4 IES013ZE-A
3.3 3.2 to 3.4 18 to 36 4 DFA20E24S3.3
3.3 2.6 to 3.5 8.4 to 36 4.5 20IMX15-03-8R
3.3 2.6 to 3.5 16.8 to 75 4.5 40IMX15-03-8R
3.3 2.6 to 3.5 50 to 150 4.5 110IMY15-03-8R
3.3 3 to 3.6 34 to 75 5 OBS017ZE
3.3 3 to 3.6 36 to 72 10 OES033ZE-A
5 to 5.2Vout
5 N/A 4.5 to 5.5 0.1 DSP1N5S5
5 N/A 4.7 to 5.5 0.3 BRS505
5 N/A 36 to 72 0.5 BWS4805
5 N/A 8.4 to 36 0.7 20IMX4-05-8
5 N/A 16.8 to 75 0.7 40IMX4-05-8
5 N/A 40 to 121 0.7 70IMX4-05-8
5 N/A 9 to 27 1 DFA6U12S5
5 N/A 18 to 36 1 24IMS6-05-9
5 N/A 20 to 60 1 DFA6U48S5
5 N/A 36 to 75 1 48IMS6-05-9
5 N/A 3.5 to 16 1.2 DFC6U5S5
BRS1.25 x 0.80 x 0.40 inch31.8 x 20.3 x 10.2 mm
BWS1.25 X 0.80 X 0.52 inch31.8 X 20.3 X 13.2 mm
DFA202.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
DFA62.12 x 1.08 x 0.48 inch53.9 x 27.4 x 12.2 mm
DFC62.00 x 1.00 x 0.45 inch50.8 x 25.4 x 11.4 mm
DSP10.77 x 0.40 x 0.27 inch19.6 x 10.2 x 6.9 mm
FBC & FES4.60 x 2.40 x 0.50 inch116.8 x 61.0 x 12.7 mm
IES2.00 x 1.00 x 0.52 inch50.8 x 25.4 x 13.2 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
36 to 72 2.5 2.3 to 2.7 45 TES113ZD-A
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
36 to 75 3.3 3 to 3.6 60 FES200ZE-A
36 to 75 12 10.8 to 13.2 42 FBC42ZH
Thru-Hole > Single-Output > Full-Brick
Thru-Hole > Single-Output > Non-Brick
DFC102.02 x 1.02 x 0.41 inch51.3 x 25.9 x 10.7 mm
DFC152.02 x 1.62 x 0.55 inch51.3 x 41.2 x 13.8 mm
DGP122.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
EWS2.00 X 1.00 X 0.40 inch50.8 X 25.4 X 10.2 mm
IAS2.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.7 mm
IMS61.3 x 0.79 x 0.33 inch
33 x 20 x 8.5 mm
Thru-Hole > Single-Output > 3/4 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
19
Alpha-sorted graphics anddimensions augment modellistings from both pages.
TES3.45 x 2.40 x 0.50 inch87.6 x 61.0 x 12.7 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
5 to 5.2Vout (Continued)5 4.5 to 5.5 3.5 to 16 2 DGP12U5S5
5 N/A 9 to 18 2 DFC10E12S5
5 N/A 18 to 36 2 DFC10E24S5
5 4.5 to 5.5 34 to 75 2 IAS010ZG
5 N/A 36 to 72 2 DFC10E48S5
5 3.8 to 5.2 50 to 150 2.8 110IMY15-05-05-8
5 4.5 to 5.5 18 to 36 3 LES015YG
5 4.8 to 5.3 20 to 60 3 DFC15U48S5
5 4.5 to 5.5 36 to 75 3 LES015ZG
5 4.8 to 5.3 18 to 36 4 DFA20E24S5
5 4.8 to 5.3 9 to 18 4 DFA20E12S5
5 4.5 to 5.5 16 to 36 4 IES020YG-A
5 4.5 to 5.5 36 to 72 4 IES020ZG-A
5 4.5 to 5.5 34 to 75 5 OBS025ZG
5 4.5 to 5.5 36 to 72 8 OES040ZG-A
5.1 3.8 to 5.4 8.4 to 36 1.2 20IMX7-05-8
5.1 3.8 to 5.4 16.8 to 75 1.2 40IMX7-05-8
5.1 3.8 to 5.4 40 to 121 1.2 70IMX7-05-8
5.1 3.8 to 5.4 60 to 150 1.2 110IMX7-05-8
5.1 4.1 to 5.4 8.4 to 36 2.3 20IMX15-05-8R
5.1 4.1 to 5.4 16.8 to 75 2.5 40IMX15-05-8R
5.1 3.8 to 5.4 50 to 150 2.5 110IMY15-05-8R
5.1 4.1 to 5.4 14 to 36 2.7 24IMS15-05-9R
5.1 4.1 to 5.4 36 to 75 2.7 48IMS15-05-9R
5.1 4 to 5.3 8.4 to 36 3.5 20IMX15-05-8R5.1 3.8 to 5.3 16.8 to 75 3.5 40IMX15-05-8R
5.1 3.8 to 5.3 50 to 150 3.5 110IMY15-05-8R
5.2 N/A 3.5 to 16 1.2 DFC6U5S5.2
7 to 9Vout7 N/A 4.5 to 5.5 0.1 DSP1N5S7
9 N/A 4.7 to 5.5 0.2 BRS509
12Vout12 N/A 4.5 to 5.5 0.08 DSP1N5S12
12 N/A 8.4 to 36 0.3 20IMX4-12-8
12 N/A 16.8 to 75 0.3 40IMX4-12-8
12 N/A 3.5 to 16 0.5 DFC6U5S12
12 N/A 4.5 to 9 0.5 EWS512
12 N/A 9 to 27 0.5 DFA6U12S12
12 N/A 20 to 60 0.5 DFA6U48S12
12 N/A 36 to 75 0.5 48IMS6-12-9
12 N/A 9 to 18 0.9 DFC10E12S12
12 N/A 18 to 36 0.9 DFC10E24S12
12 10.8 to 13.2 3.5 to 16 1 DGP12U5S12
Continued on Next Page
IMX152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMY152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMX41.30 x 0.79 x 0.33 inch33.0 x 20.1 x 8.5 mm
IMX72.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.5 mm
LES2.00 x 1.00 x 0.40 inch50.8 x 25.4 x 10.2 mm
OES2.00 x 2.00 x 0.42 inch50.8 x 50.8 x 10.7 mm
OBS2.00 x 2.00 x 0.42 inch50.8 x 50.8 x 10.7 mm
IMS152.00 x 1.60 x 0.41 inch50.8 x 40.6 x 10.5 mm
Thru-Hole > Single-Output > Non Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
20
IMS61.3 x 0.79 x 0.33 inch
33 x 20 x 8.5 mm
IMY152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMX41.30 x 0.79 x 0.33 inch33.0 x 20.1 x 8.5 mm
LES2.00 x 1.00 x 0.40 inch50.8 x 25.4 x 10.2 mm
OBS2.00 x 2.00 x 0.42 inch50.8 x 50.8 x 10.7 mm
OWS2.00 x 2.00 x 0.50 inch50.8 x 50.8 x 12.7 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
12 10.8 to 13.2 18 to 36 1.2 LES015YH
12 11.4 to 12.6 20 to 60 1.2 DFC15U48S12
12 9 to 12.6 50 to 150 1.4 110IMY15-12-12-8
12 11.4 to 12.6 9 to 18 1.7 DFA20E12S12
12 11.4 to 12.6 18 to 36 1.7 DFA20E24S12
12 10.8 to 13.2 10 to 20 2.1 OWS1212
12 10.8 to 13.2 34 to 75 2.1 OBS025ZH
14 to 15Vout14 N/A 4.5 to 5.5 0.07 DSP1N5S14
15 N/A 4.7 to 5.5 0.07 DSP1N5S15
15 N/A 8.4 to 36 0.3 20IMX4-15-8
15 N/A 16.8 to 75 0.3 40IMX4-15-8
15 N/A 40 to 121 0.3 70IMX4-15-8
15 N/A 3.5 to 16 0.4 DFC6U5S15
15 N/A 9 to 27 0.4 DFA6U12S15
15 N/A 20 to 60 0.4 DFA6U48S15
15 N/A 36 to 75 0.4 48IMS6-15-9
15 N/A 9 to 18 0.7 DFC10E12S15
15 N/A 18 to 36 0.7 DFC10E24S15
15 N/A 36 to 72 0.7 DFC10E48S15
15 13.5 to 16.5 18 to 36 0.8 IAS012YJ
15 11.2 to 15.8 50 to 150 1.2 110IMY15-15-15-8
15 14.3 to 15.8 9 to 18 1.4 DFA20E12S15
15 14.3 to 15.8 18 to 36 1.4 DFA20E24S15
17 to 24Vout17 N/A 4.5 to 5.5 0.06 DSP1N5S17
DFA202.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
DFA62.12 x 1.08 x 0.48 inch53.9 x 27.4 x 12.2 mm
DFC62.00 x 1.00 x 0.45 inch50.8 x 25.4 x 11.4 mm
DFC102.02 x 1.02 x 0.41 inch51.3 x 25.9 x 10.7 mm
DFC152.02 x 1.62 x 0.55 inch51.3 x 41.2 x 13.8 mm
DSP10.77 x 0.40 x 0.27 inch19.6 x 10.2 x 6.9 mm
IAS2.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.7 mm
Thru-Hole > Single-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
21
2.30 x 1.45 x 0.28 inch58.4 x 36.8 x 7.2 mm
• Independently-RegulatedOutputs
• Minimal Cross-ChannelInterference
• Startup into Pre-biasedOutputs
• Industry-Standard Footprint& Pinout
QD48T
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Nominal 48Vin
36 to 75 +1.2 1.1 to 1.3 15 41 QD48T012015+1.5 1.4 to 1.7 15
36 to 75 +1.2 1.1 to 1.3 15 45 QD48T012018+1.8 1.6 to 2 15
36 to 75 +1.2 1.1 to 1.3 15 56 QD48T012025+2.5 2.3 to 2.8 15
36 to 75 +1.2 1.1 to 1.3 15 68 QD48T012033+3.3 3 to 3.6 15
36 to 75 +1.5 1.4 to 1.7 15 50 QD48T015018+1.8 1.6 to 2 15
36 to 75 +1.5 1.4 to 1.7 15 60 QD48T015025+2.5 2.3 to 2.8 15
36 to 75 +1.5 1.4 to 1.7 15 72 QD48T015033+3.3 3 to 3.6 15
36 to 75 +1.5 1.4 to 1.7 15 73 QD48T015050+5 4.5 to 5.5 10
36 to 75 +1.8 1.6 to 2 15 65 QD48T018025+2.5 2.3 to 2.8 15
36 to 75 +1.8 1.6 to 2 15 77 QD48T018033+3.3 3 to 3.6 15
36 to 75 +1.8 1.6 to 2 15 77 QD48T018050+5 4.5 to 5.5 10
36 to 75 +2 1.8 to 2.2 15 80 QD48T020033+3.3 3 to 3.6 15
36 to 75 +2.5 2.3 to 2.8 15 87 QD48T025033+3.3 3 to 3.6 15
36 to 75 +3.3 3 to 3.6 15 100 QD48T033050+5 4.5 to 5.5 10
Thru-Hole > Dual-Output > 1/4 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
22
2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
• Industry Standard 1/2-Brick• Flexible Load Distribution• 1500 VDC Input-to-Output
Isolation
HBD & HHD
2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
• Industry Standard Half-Brick• Planar Magnetics• Startup into High Capacitive
Load• Independently-Regulated
Outputs
HLD
2.40 x 2.28 x 0.50 inch61.0 x 57.9 x 12.7 mm
• 75 Watts Total Power• Wide Input Range; 18-60 VDC• Flexible Load Sharing• Independently-Regulated
Outputs
HWD
2.30 x 1.45 x 0.40 inch58.4 x 36.8 x 10.2 mm
• Dual Outputs: 2 to 5 VDC• Up to 100 Watts Total Power• 18-36 and 36-72 VDC Inputs
TQD
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
18 to 36Vin18 to 36 3.3 3 to 3.6 12 40 HBD040YGE-A
5 4.5 to 5.5 8
18 to 36 3.3 3 to 3.6 15 60 HBD060YGE-A5 4.5 to 5.5 12
18 to 60Vin
18 to 60 3.3 3 to 3.6 15 75 HWD075DGE-A5 4.5 to 5.5 15
Nominal 48Vin
36 to 72 1.8 1.6 to 2 15 60 HLD15ZEB3.3 3 to 3.6 15
34 to 75 2.5 2.3 to 2.8 15 40 HBD040ZED-A3.3 3 to 3.6 12
36 to 72 2.5 2.3 to 2.8 20 100 HHD25ZED3.3 3 to 3.6 25
34 to 75 3.3 3 to 3.6 12 40 HBD040ZGE-A5 4.5 to 5.5 8
34 to 75 3.3 3 to 3.6 15 60 HBD060ZGE-A5 4.5 to 5.5 12
36 to 72 3.3 3 to 3.6 15 60 HLD15ZGE5 4.5 to 5.5 12
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Nominal 48Vin
36 to 72 2.5 2.3 to 2.8 25 85 TQD085ZED-A3.3 3 to 3.6 20
36 to 72 3.3 3 to 3.6 25 100 TQD100ZGE-A5 4.5 to 5.5 20
Thru-Hole > Dual-Output > 3/4-Brick
Thru-Hole > Dual-Output > 1/2 Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
23
DFC102.02 x 1.02 x 0.42 inch51.3 x 25.9 x 10.7 mm
DSP10.77 x 0.40 x 0.27 inch19.6 x 10.2 x 6.9 mm
IMS61.3 x 0.79 x 0.33 inch
33 x 20 x 8.5 mm
IMS152.00 x 1.60 x 0.41 inch50.8 x 40.6 x 10.5 mm
IMS302.00 x 2.00 x 0.37 inch50.8 x 50.8 x 9.4 mm
IMX41.30 x 0.79 x 0.33 inch33.0 x 20.1 x 8.5 mm
IMX72.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.5 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
3.3V and 5.1V Outputs
8.4 to 36 +3.3 2.5 to 3.5 1.4 11.3 20IMX15-0503-8R+5.1 3.8 to 5.4 1.4
16.8 to 75 +3.3 2.5 to 3.5 1.5 12.6 40IMX15-0503-8R+5.1 3.8 to 5.4 1.5
50 to 150 +3.3 2.5 to 3.5 1.5 12.6 110IMY15-0503-8R+5.1 3.8 to 5.3 1.5
14 to 36 +3.3 2.5 to 3.5 1.6 13.5 24IMS15-0503-9R+5.1 3.8 to 5.4 1.6
36 to 75 +3.3 2.5 to 3.5 1.6 13.5 48IMS15-0503-9R+5.1 3.8 to 5.4 1.6
32 to 75 +3.3 3 to 3.6 4.2 30 48IMS30-0503-9+5.1 4.6 to 5.6 3.1
5V Both Outputs
4.5 to 5.5 +5 N/A 0.07 0.8 DSP1N5D5-5 N/A 0.07
8.4 to 36 +5 N/A 0.3 3.5 20IMX4-0505-8-5 N/A 0.3
16.8 to 75 +5 N/A 0.3 3.5 40IMX4-0505-8-5 N/A 0.3
40 to 121 +5 N/A 0.3 3.5 70IMX4-0505-8-5 N/A 0.3
18 to 36 +5 N/A 0.5 5 24IMS6-0505-9-5 N/A 0.5
8.4 to 36 5 3.8 to 5.2 0.6 6 20IMX7-05-05-85 3.8 to 5.2 0.6
16.8 to 75 5 3.8 to 5.2 0.7 7 40IMX7-05-05-85 3.8 to 5.2 0.7
40 to 121 5 3.8 to 5.2 0.7 7 70IMX7-05-05-85 3.8 to 5.2 0.7
60 to 150 5 3.8 to 5.2 0.7 7 110IMX7-05-05-85 3.8 to 5.2 0.7
9 to 36 +5 N/A 0.8 8.5 DFC10U24D5-5 N/A 0.8
Continued on Next Page
IMX152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMY152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
Thru-Hole > Dual-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
24
IMX152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMY152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
3.5 to 16 +5 4.5 to 5.5 1 10 DGP12U5D5-5 4.5 to 5.5 1
8.4 to 36 5 3.8 to 5.3 1.3 13 20IMX15-05-05-85 3.8 to 5.3 1.3
14 to 36 5 3.8 to 5.3 1.4 14 24IMS15-05-05-95 3.8 to 5.3 1.4
16.8 to 75 5 3.8 to 5.3 1.4 14 40IMX15-05-05-85 3.8 to 5.3 1.4
36 to 75 5 3.8 to 5.3 1.4 14 48IMS15-05-05-95 3.8 to 5.3 1.4
50 to 150 5 3.8 to 5.2 1.4 14 110IMY15-05-05-85 3.8 to 5.2 1.4
18 to 36 +5 4.8 to 5.3 1.7 17 DFA20E24D5-5 4.8 to 5.3 1.7
12V Both Outputs
4.5 to 5.5 +12 N/A 0.04 1 DSP1N5D12-12 N/A 0.04
8.4 to 36 +12 N/A 0.2 4 20IMX4-1212-8-12 N/A 0.2
16.8 to 75 +12 N/A 0.2 4 40IMX4-1212-8-12 N/A 0.2
8.4 to 36 12 9 to 12.6 0.2 6 20IMX7-12-12-812 9 to 12.6 0.2
18 to 36 +12 N/A 0.2 6 24IMS6-1212-9-12 N/A 0.2
16.8 to 75 12 9 to 12.6 0.3 7 40IMX7-12-12-812 9 to 12.6 0.3
40 to 121 12 9 to 12.6 0.3 7 70IMX7-12-12-812 9 to 12.6 0.3
60 to 150 12 9 to 12.6 0.3 7 110IMX7-12-12-812 9 to 12.6 0.3
9 to 36 +12 N/A 0.4 10 DFC10U24D12-12 N/A 0.4
Continued on Next Page
BWD1.25 x 0.80 x 0.52 inch31.8 x 20.3 x 13.2 mm
IMS152.00 x 1.50 x 0.42 inch51.0 x 40.6 x 10.5 mm
IMX41.25 x 0.8 x 0.33 inch
32 x 20 x 8.5 mm
IMX72.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.5 mm
DFA202.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
DFC101.02 x 2.02 x 0.41 inch25.9 x 51.3 x 10.7 mm
DGP122.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
DSP10.77 x 0.40 x 0.27 inch19.6 x 10.2 x 6.9 mm
IMS61.3 x 0.79 x 0.33 inch
33 x 20 x 8.5 mm
Thru-Hole > Dual-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
25
See opposing page fordimensions.
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
12V Both Outputs (Continued)
18 to 72 +12 N/A 0.4 10 DFC10U48D12-12 N/A 0.4
3.5 to 16 +12 10.8 to 13.2 0.5 12 DGP12U5D12-12 10.8 to 13.2 0.5
8.4 to 36 12 9 to 12.6 0.7 15.6 20IMX15-12-12-812 9 to 12.6 0.7
14 to 36 12 9 to 12.6 0.7 16.8 24IMS15-12-12-912 9 to 12.6 0.7
16.8 to 75 12 9 to 12.6 0.7 16.8 40IMX15-12-12-812 9 to 12.6 0.7
36 to 75 12 9 to 12.6 0.7 16.8 48IMS15-12-12-912 9 to 12.6 0.7
50 to 150 12 9 to 12.6 0.7 16.8 110IMY15-12-12-812 9 to 12.6 0.7
9 to 18 +12 11.4 to 12.6 0.8 20.4 DFA20E12D12-12 11.4 to 12.6 0.8
14V Both Outputs
4.5 to 5.5 +14 N/A 0.04 1 DSP1N5D14-14 N/A 0.04
15V Both Outputs
4.5 to 5.5 +15 N/A 0.03 1 DSP1N5D15-15 N/A 0.03
18 to 36 +15 N/A 0.1 3 BWD2415-15 N/A 0.1
36 to 72 +15 N/A 0.1 3 BWD4815-15 N/A 0.1
8.4 to 36 +15 N/A 0.1 4.2 20IMX4-1515-8-15 N/A 0.1
16.8 to 75 +15 N/A 0.1 4.2 40IMX4-1515-8-15 N/A 0.1
8.4 to 36 15 11.2 to 15.8 0.2 6 20IMX7-15-15-815 11.2 to 15.8 0.2
Continued on Next Page
Thru-Hole > Dual-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
26
IMX152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMY152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
15V Both Outputs (Continued)
16.8 to 75 15 11.2 to 15.8 0.2 7 40IMX7-15-15-815 11.2 to 15.8 0.2
40 to 121 15 11.2 to 15.8 0.2 7 70IMX7-15-15-815 11.2 to 15.8 0.2
60 to 150 15 11.2 to 15.8 0.2 7 110IMX7-15-15-815 11.2 to 15.8 0.2
9 to 36 +15 N/A 0.3 9.6 DFC10U24D15-15 N/A 0.3
18 to 72 +15 N/A 0.3 9.9 DFC10U48D15-15 N/A 0.3
3.5 to 16 +15 13.5 to 16.5 0.4 12 DGP12U5D15-15 13.5 to 16.5 0.4
8.4 to 36 15 11.3 to 15.8 0.5 15 20IMX15-15-15-815 11.3 to 15.8 0.5
14 to 36 15 11.3 to 15.8 0.6 16.8 24IMS15-15-15-915 11.3 to 15.8 0.6
16.8 to 75 15 11.3 to 15.8 0.6 16.8 40IMX15-15-15-815 11.3 to 15.8 0.6
36 to 75 15 11.3 to 15.8 0.6 16.8 48IMS15-15-15-915 11.3 to 15.8 0.6
50 to 150 15 11.2 to 15.8 0.6 16.8 110IMY15-15-15-815 11.2 to 15.8 0.6
18 to 36 +15 14.3 to 15.8 0.7 21 DFA20E24D15-15 14.3 to 15.8 0.7
17V Both Outputs
4.5 to 5.5 +17 N/A 0.03 1 DSP1N5D17-17 N/A 0.03
Continued on Next Page
DFC152.02 x 1.62 x 0.55 inch51.3 x 41.2 x 13.97 mm
IAD2.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.7 mm
DFA202.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
DFC101.02 x 2.02 x 0.41 inch25.9 x 51.3 x 10.7 mm
DGP122.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
DSP10.77 x 0.40 x 0.27 inch19.6 x 10.2 x 6.9 mm
Thru-Hole > Dual-Output > Non-Brick
IMS152.00 x 1.50 x 0.42 inch51.0 x 40.6 x 10.5 mm
IMX72.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.5 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Dual & Triple Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
27
IMS152.00 x 1.50 x 0.42 inch51.0 x 40.6 x 10.5 mm
IMX41.25 x 0.8 x 0.33 inch
32 x 20 x 8.5 mm
IMX72.00 x 1.00 x 0.42 inch50.8 x 25.4 x 10.5 mm
IMX152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
IMY152.00 x 1.50 x 0.42 inch50.8 x 38.1 x 10.7 mm
QNT2.30 x 1.45 x 0.38 inch58.4 x 36.8 x 9.7 mm
• Extremely-Wide OutputVoltage Adjustment Range
• Programmable Sequencingand Cascading
• Single-Board Design• Low Profile; < 9.5 mm height• 1500 VDC Input-to-Output
Isolation
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
24V Both Outputs
8.4 to 36 +24 N/A 0.08 3.8 20IMX4-2424-8-24 N/A 0.08
16.8 to 75 +24 N/A 0.08 3.8 40IMX4-2424-8-24 N/A 0.08
8.4 to 36 24 18 to 25.2 0.1 6 20IMX7-24-24-824 18 to 25.2 0.1
16.8 to 75 24 18 to 25.2 0.1 7 40IMX7-24-24-824 18 to 25.2 0.1
40 to 121 24 18 to 25.2 0.1 7 70IMX7-24-24-824 18 to 25.2 0.1
60 to 150 24 18 to 25.2 0.1 7 110IMX7-24-24-824 18 to 25.2 0.1
8.4 to 36 24 18 to 25.2 0.3 15.4 20IMX15-24-24-824 18 to 25.2 0.3
14 to 36 24 18 to 25.2 0.3 16.8 24IMS15-24-24-924 18 to 25.2 0.3
16.8 to 75 24 18 to 25.2 0.3 16.8 40IMX15-24-24-824 18 to 25.2 0.3
36 to 75 24 18 to 25.2 0.3 16.8 48IMS15-24-24-924 18 to 25.2 0.3
50 to 150 24 18 to 25.2 0.3 16.8 110IMY15-24-24-824 18 to 25.2 0.3
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model36 to 75 +3.3 1.4 to 5 12 80 QNT36ZEDB
+2.5 1.2 to 3.6 12+1.8 0.9 to 3.6 12
Thru-Hole > Triple-Output > 1/4-Brick
Thru-Hole > Dual-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Triple Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
28
IMX353.00 x 2.50 x 0.41 inch76.2 x 63.5 x 10.4 mm
• 1500 VDC Isolation• Extremely Wide Input Voltage
Ranges
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Three 5V Outputs
9 to 36 5 4.2 to 5.2 1.4 35 20IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 2.7
18 to 75 5 4.2 to 5.2 1.4 35 40IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 2.8
40 to 121 5 4.2 to 5.2 1.4 35 70IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 2.8
60 to 150 5 4.2 to 5.2 1.4 35 110IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 2.8
Two 5V and One 12V Output
9 to 36 5 4.2 to 5.2 1.4 35 20IMX35D05D12-85 4.2 to 5.2 1.412 10.2 to 12.6 1.3
18 to 75 5 4.2 to 5.2 1.4 35 40IMX35D05D12-85 4.2 to 5.2 1.412 10.2 to 12.6 1.4
40 to 121 5 4.2 to 5.2 1.4 35 70IMX35D05D12-85 4.2 to 5.2 1.412 10.2 to 12.6 1.4
60 to 150 5 4.2 to 5.2 1.4 35 110IMX35D05D12-85 4.2 to 5.2 1.412 10.2 to 12.6 1.4
Two 5V and One 15V Output
9 to 36 5 4.2 to 5.2 1.4 35 20IMX35D05D15-85 4.2 to 5.2 1.415 12.8 to 15.8 1.1
18 to 75 5 4.2 to 5.2 1.4 35 40IMX35D05D15-85 4.2 to 5.2 1.415 12.8 to 15.8 1.2
40 to 121 5 4.2 to 5.2 1.4 35 70IMX35D05D15-85 4.2 to 5.2 1.415 12.8 to 15.8 1.2
60 to 150 5 4.2 to 5.2 1.4 35 110IMX35D05D15-85 4.2 to 5.2 1.415 12.8 to 15.8 1.2
IMX35 outputs can be paralleled and stacked to provide additional voltage/currentcombinations. Please download the IMX35 data sheet for further details.
Thru-Hole > Triple-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Triple Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
29
DFC253.00 x 2.50 x 0.43 inch76.2 x 63.5 x 11.0 mm
DGP202.02 x 2.02 x 0.45 inch51.3 x 51.3 x 11.4 mm
IMX353.00 x 2.50 x 0.41 inch76.2 x 63.5 x 10.4 mm
• 1500 VDC Isolation• Extremely Wide Input Voltage
Ranges• Triple-output configurations
of this quad-output seriesutilize two outputs in parallel
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
5V and Two 12V Outputs18 to 36 +5 N/A 2.5 20 DGP20E24T5/12
+12 N/A 0.3-12 N/A 0.3
36 to 72 +5 N/A 2.5 20 DGP20E48T5/12+12 N/A 0.3-12 N/A 0.3
36 to 72 +5 4.5 to 5.5 5 25 DFC25E48T5/12+12 N/A 1-12 N/A 1
9 to 36 5 4.2 to 5.2 2.7 35 20IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.7
18 to 75 5 4.2 to 5.2 2.8 35 40IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.7
40 to 121 5 4.2 to 5.2 2.8 35 70IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.7
60 to 150 5 4.2 to 5.2 2.8 35 110IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.7
5V and Two 15V Outputs18 to 36 +5 N/A 2.5 20 DGP20E24T5/15
+15 N/A 0.2-15 N/A 0.2
9 to 36 5 4.2 to 5.2 2.7 35 20IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.6
18 to 75 5 4.2 to 5.2 2.8 35 40IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.6
40 to 121 5 4.2 to 5.2 2.8 35 70IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.6
60 to 150 5 4.2 to 5.2 2.8 35 110IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.6
Continued on Next Page
Thru-Hole > Triple-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Triple Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
30
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Three 12V Outputs
9 to 36 12 10.2 to 12.6 0.7 35 20IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 1.3
18 to 75 12 10.2 to 12.6 0.7 35 40IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 1.4
40 to 121 12 10.2 to 12.6 0.7 35 70IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 1.4
60 to 150 12 10.2 to 12.6 0.7 35 110IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 1.4
Three 15V Outputs
9 to 36 15 12.8 to 15.8 0.6 35 20IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 1.1
18 to 75 15 12.8 to 15.8 0.6 35 40IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 1.2
40 to 121 15 12.8 to 15.8 0.6 35 70IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 1.2
60 to 150 15 12.8 to 15.8 0.6 35 110IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 1.2
IMX353.00 x 2.50 x 0.41 inch76.2 x 63.5 x 10.4 mm
• 1500 VDC Isolation• Extremely Wide Input Voltage
Ranges• Independent Outputs Can Be
Used in Series or Parallel
Thru-Hole > Triple-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Isolated DC-DC > Thru-Hole > Quad Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
31
IMX353.00 x 2.50 x 0.41 inch76.2 x 63.5 x 10.4 mm
• 1500 VDC Isolation• Extremely Wide Input Voltage
Ranges• Independent Outputs Can Be
Used in Series or Parallel
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Four 5V Outputs
9 to 36 5 4.2 to 5.2 1.35 27 20IMX35D05D05-85 4.2 to 5.2 1.355 4.2 to 5.2 1.355 4.2 to 5.2 1.35
18 to 75 5 4.2 to 5.2 1.4 28 40IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 1.45 4.2 to 5.2 1.4
40 to 121 5 4.2 to 5.2 1.4 28 70IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 1.45 4.2 to 5.2 1.4
60 to 150 5 4.2 to 5.2 1.4 28 110IMX35D05D05-85 4.2 to 5.2 1.45 4.2 to 5.2 1.45 4.2 to 5.2 1.4
Two 5V and Two 12V Outputs
9 to 36 5 4.2 to 5.2 1.35 29 20IMX35D05D12-812 10.2 to 12.6 0.6512 10.2 to 12.6 0.655 4.2 to 5.2 1.35
18 to 75 5 4.2 to 5.2 1.4 30 40IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.75 4.2 to 5.2 1.4
40 to 121 5 4.2 to 5.2 1.4 30 70IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.75 4.2 to 5.2 1.4
60 to 150 5 4.2 to 5.2 1.4 30 110IMX35D05D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.75 4.2 to 5.2 1.4
Two 5V and Two 15V Outputs
9 to 36 5 4.2 to 5.2 1.35 30 20IMX35D05D15-815 12.8 to 15.8 0.5515 12.8 to 15.8 0.555 4.2 to 5.2 1.35
18 to 75 5 4.2 to 5.2 1.4 32 40IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.65 4.2 to 5.2 1.4
40 to 121 5 4.2 to 5.2 1.4 32 70IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.65 4.2 to 5.2 1.4
60 to 150 5 4.2 to 5.2 1.4 32 110IMX35D05D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.65 4.2 to 5.2 1.4
Thru-Hole > Quad-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Isolated DC-DC > Thru-Hole > Quad Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
32
Input Factory Output MaxVoltage Set Vout Trim Range Amps Watts Model
Four 12V Outputs
9 to 36 12 10.2 to 12.6 0.65 31 20IMX35D12D12-812 10.2 to 12.6 0.6512 10.2 to 12.6 0.6512 10.2 to 12.6 0.65
18 to 75 12 10.2 to 12.6 0.7 34 40IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.712 10.2 to 12.6 0.7
40 to 121 12 10.2 to 12.6 0.7 34 70IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.712 10.2 to 12.6 0.7
60 to 150 12 10.2 to 12.6 0.7 34 110IMX35D12D12-812 10.2 to 12.6 0.712 10.2 to 12.6 0.712 10.2 to 12.6 0.7
Four 15V Outputs
9 to 36 15 12.8 to 15.8 0.55 33 20IMX35D15D15-815 12.8 to 15.8 0.5515 12.8 to 15.8 0.5515 12.8 to 15.8 0.55
18 to 75 15 12.8 to 15.8 0.6 35 40IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.615 12.8 to 15.8 0.6
40 to 121 15 12.8 to 15.8 0.6 35 70IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.615 12.8 to 15.8 0.6
60 to 150 15 12.8 to 15.8 0.6 35 110IMX35D15D15-815 12.8 to 15.8 0.615 12.8 to 15.8 0.615 12.8 to 15.8 0.6
IMX353.00 x 2.50 x 0.41 inch76.2 x 63.5 x 10.4 mm
• 1500 VDC Isolation• Extremely Wide Input Voltage
Ranges• Independent Outputs Can Be
Used in Series or Parallel
Thru-Hole > Input Filters
MaxCurrent Voltage Meets(Amps) (VDC) Mounting Conducted Part Number5 100 Through-Hole FCC Class B FC100V5A
10 100 Through-Hole FCC Class B FC100V10A
20 100 Through-Hole FCC Class B FC100V20A
Thru-Hole > Quad-Output > Non-Brick
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Z-One® Digital Power
33
The Industry’s First Multi-Source Digital Power Products
With products ranging from the No-Bus™ Z-1000 Point-Of-Load(POL) converters to the I2C programmable Z-7000 Series, Z-One®
Digital Power can provide the advantages of integrated power
management and conversion to any application. In addition to theoverview information presented on these two pages, please refer tothe POL section for model listings.
No-Bus™ Z-1000 POLs Z-7000 POLs and Digital Power Managers
PowerManagement
Interface Hardwareconfigurable I2C programmable
Features No external controlleror bus required
DPM provides unprecedentedpower management options
ParameterSelection
What
• Vout• Turn-on delays• Feedback loop compensation• Interleave
• Fault management• Slew rates• Interleave• Protections• Power Good• Vout
• Frequency• Up to four
analog components• Feedback loop
compensation• Turn-on delays
How Pin strapping and only one trim resistor and capacitor
I2C programming capabilitiesinclude a wizard-driven GUI
TelemetryWhat Current and temperature Voltage, current, and temperature
How Digital and analog signals Via I2C bus
Z-1000 and Z-7000 POL Converters ZM-7000 Digital Power Managers (DPMs)
Packages
Input Voltage 3 to 14 VDC
Output Voltage User defined outputs from 0.5 to 5.5 VDC
Current Ratings Ranges of 7 to 20 amp models extended by current share capabilities
Current Density 20A POL provides 50 A/in2 from a 0.4 in2 footprint
Migration Paths Common Z-1000 and Z-7000 footprints simplify power system migrations
Customizations The silicon-based technologies that provide Z-One® Digital Power with unprecedented power-management capabilities can be readily adapted to meet the needs of specific applications. Please contact your Power-One representative to discuss how this proven-technology approach can be cost-effectively
implemented to address your custom point of load requirements.
9 mm
• Programs, controls, and monitors up to 32 Z-7000 POLs and up to four analog devices.
• Ensures data integrity by storing configuration instructions in non-volatile memory.
• Collects Z-7000 POL performance data (output voltage, output current, POL temperature, and protection status).
• Monitors the intermediate bus, accepts interrupts, initiates crowbar protection, and interfaces with dc-dc bus converters and ac-dc front ends.
Vertical and Horizontal SMT ZM7300 Digital Power Manager
A Digital Power Management Architecture for Every Application
Power-One firmly believes that customers should have choices andhas entered into licensing agreements with other manufacturers thatprovides customers, for the first time ever, with multiple-sourceproducts that utilize digital feedback loops and digital Pulse Width
Modulation (PWM) controllers. These true digitalproducts provide a unique combination of value,performance, and power management options.
Z-One® Series Information Continued on Next Page
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Z-One® Digital Power
34
Signals and Protections• Reporting of output current and
temperature via signal pins.• Thresholds for overvoltage,
undervoltage, and Power Goodtrack the output voltage settings.
Output Voltages and Currents• Output voltages (0.5 to 5.5 V) and turn-on delays are configured
with an external resistor and a capacitor, respectively.• Up to ten Z-1000 POLs can current share using a single control trace.• Z-1000 POLs can start up with pre-biased outputs.• Sink and source current capabilities for active bus termination.
Coordination andOptimization via
Simple Pin Strapping• Frequency synchronization and
phase interleaving reduces EMI.• Comprehensive sequencing and
cascading management.• Feedback loop compensation and
enable logic.• Frequency synchronization, fault
propagation, and current sharing areimplemented, without externalcomponents, by interconnectingpins on the Z-POLs beingcoordinated.
▼▼
▼
▼
Z-1000 POLs, No Controllers, No Programming
Z-7000 Series Dramatically Simplifies Power System Development
The Z-7000 Series combines many innovative operating concepts toachieve an unprecedented level of power-system integration. Amultitude of parameters, such as output voltages, sequencing,tracking, and protection limits are user-programmed through agraphical user interface and stored in a Digital Power Manager.
Unlike other power management solutions it does not require usersto provide an I2C interface, host processor, or non-volatile memory;Z-One® Digital Power operates autonomously in any system.• Open architecture based on industry standard I2C interface.• Reduces the number of unique models in inventory.
• Extremely scalable architecture provides up to 32 programmableoutputs from 0.5 to 5.5 VDC.
• Reduced component count improves cost, reliability, and powerdensity.
• GUI-driven configuration and simulation simplifies power systemdevelopment, accelerating time to market.
• Fully-integrated solution eliminates component incompatibilityissues.
• Manages up to four analog components including VRMs, POLs,fans, and linear regulators.
▼▼
Z-1000 No-Bus™ POLs provide sophisticated power managementcapabilities without the cost and complexity of third-party controllers andthe communication bus interfaces required by analog architectures.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
POL Management and Conversion
Unsigned output voltages are isolated and can be used as either + or - polarities.
35
1.25 x 0.55 x 0.31 inch32 x 14 x 8 mm
ZY11XX & ZY71XX
1.25 x 0.55 x 0.28 inch32 x 14 x 7.1 mm
ZY7010, ZY7015, & ZY1015
0.87 x 0.49 x 0.26 inch22.2 x 12.5 x 6.5 mm
ZY7007 & ZY1207
• Controls up to 32 Z-7000 POLsand 4 analog components
• Compact 9 x 9 mm package
ZM7300 Digital Power Manager
Z-7000 Series Digital POLsInput Default Vout MaxVoltage Vout Program Range Amps Model3 to 14 +0.5 +0.5 to +5.5 7 ZY7007
3 to 14 +0.5 +0.5 to +5.5 10 ZY7010
3 to 14 +0.5 +0.5 to +5.5 15 ZY7015
3 to 14 +0.5 +0.5 to +5.5 15 ZY7115
3 to 14 +0.5 +0.5 to +5.5 20 ZY7120
Input Default Vout MaxVoltage Vout Trim Range Amps Model3 to 14 +0.5 +0.5 to +5.5 7 ZY1207
3 to 14 +0.5 +0.5 to +5.5 15 ZY1015
3 to 14 +0.5 +0.5 to +5.5 15 ZY1115
3 to 14 +0.5 +0.5 to +5.5 20 ZY1120
Model Digital POL Analog Component CombinedNumber Management Nodes Management Nodes Nodes*ZM7304 4 4 4
ZM7308 8 4 8
ZM7316 16 4 16
ZM7332 32 4 32
* Combined nodes are the maximum number of analog and digital components that can be concurrently managed.
Z-7000 Series Digital Power Managers
Z-1000 Series Digital POLs
Y-Series Surface-Mount POL ConvertersInput Factory Vout MaxVoltage Set Vout Trim Range Amps Model
5.5Vin and Lower3 to 5.5 +0.75 +0.75 to +3.63 5 YM05S05
3 to 5.5 +0.75 +0.75 to +3.63 6 YNM05S06
3 to 5.5 +0.75 +0.75 to +3.63 10 YS05S10
3 to 5.5 +0.75 +0.75 to +3.63 16 YS05S16
4.5 to 5.5 +0.75 +0.75 to +3.63 20 YNC05S20
3 to 5.5 +0.9 +0.85 to +0.99 10 YNL05S10009
3 to 5.5 +1 +0.9 to +1.1 10 YNL05S10010
3 to 5.5 +1.2 +1.1 to +1.3 10 YNL05S10012
3 to 5.5 +1.5 +1.4 to +1.6 10 YNL05S10015
3 to 5.5 +1.8 +1.7 to +1.9 10 YNL05S10018
3 to 5.5 +2 +1.8 to +2.2 10 YNL05S10020
3 to 5.5 +2.5 +2.3 to +2.7 10 YNL05S10025
3 to 5.5 +3.3 +3 to +3.6 10 YNL05S10033
Continued on Next Page
1.30 x 0.53 x 0.31 inch33 x 13.5 x 8 mm
0.8 x 0.45 x 0.25 inch20.3 x 11.4 x 6.3 mm
YM05S & YNM05S
YNC, YNL, & YS
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
POL Management and Conversion
36
1.30 x 0.53 x 0.31 inch33 x 13.5 x 8 mm
YNV05T06 & YNV12T05
YNV05T10, YNV05T10XXX,YNV05T16, YNV12T10,
YNV12T10XXX, & YNV12T16
0.8 x 0.45 x 0.25 inch20.3 x 11.4 x 6.3 mm
YM12S
2.0 x 0.54 x 0.28 inch50.8 x 13.6 x 7.1 mm
0.90 x 0.40 x 0.21 inch22.9 x 10.2 x 5.4 mm
YNC, YNL, & YS
2.00 x 1.25 x 0.34 inch50.8 x 31.8 x 8.5 mm
YV12T25-0
Input Factory Vout MaxVoltage Set Vout Trim Range Amps Model
5.5Vin and Lower
3 to 5.5 +0.75 +0.75 to +3.63 6 YNV05T06
3 to 5.5 +0.75 +0.75 to +3.63 10 YNV05T10
3 to 5.5 +0.75 +0.75 to +3.63 16 YNV05T16
3 to 5.5 +0.9 +0.85 to +0.99 10 YNV05T10009
3 to 5.5 +1 +0.9 to +1.1 10 YNV05T10010
3 to 5.5 +1.2 +1.1 to +1.3 10 YNV05T10012
3 to 5.5 +1.5 +1.4 to +1.6 10 YNV05T10015
3 to 5.5 +1.8 +1.7 to +1.9 10 YNV05T10018
3 to 5.5 +2 +1.8 to +2.2 10 YNV05T10020
3 to 5.5 +2.5 +2.3 to +2.7 10 YNV05T10025
3 to 5.5 +3.3 +3 to +3.6 10 YNV05T10033
9.6 to 14Vin9.6 to 14 +0.75 +0.75 to +5.5 5 YNV12T05
9.6 to 14 +0.75 +0.75 to +5.5 10 YNV12T10
9.6 to 14 +0.75 +0.75 to +5.5 16 YNV12T16
9.6 to 14 +1 +0.9 to +1.1 10 YNV12T10010
9.6 to 14 +1.2 +1.1 to +1.3 10 YNV12T10012
9.6 to 14 +1.5 +1.4 to +1.6 10 YNV12T10015
9.6 to 14 +1.8 +1.7 to +1.9 10 YNV12T10018
9.6 to 14 +2 +1.8 to +2.2 10 YNV12T10020
9.6 to 14 +2.5 +2.3 to +2.7 10 YNV12T10025
9.6 to 14 +3.3 +3 to +3.6 10 YNV12T10033
9.6 to 14 +5 +4.5 to +5.5 10 YNV12T10050
10 to 14 +1.2 +0.8 to +5.5 25 YV12T25-0
Y-Series Through-Hole POL Converters
Input Factory Vout MaxVoltage Set Vout Trim Range Amps Model
9.6 to 14Vin9.6 to 14 +0.75 +0.75 to +5.5 5 YM12S05
9.6 to 14 +0.75 +0.75 to +5.5 10 YS12S10
9.6 to 14 +0.75 +0.75 to +5.5 16 YS12S16
9.6 to 14 +0.75 +0.75 to +5.5 20 YNC12S20
9.6 to 14 +1 +0.9 to +1.1 10 YNL12S10010
9.6 to 14 +1.2 +1.1 to +1.3 10 YNL12S10012
9.6 to 14 +1.5 +1.4 to +1.6 10 YNL12S10015
9.6 to 14 +1.8 +1.7 to +1.9 10 YNL12S10018
9.6 to 14 +2 +1.8 to +2.2 10 YNL12S10020
9.6 to 14 +2.5 +2.3 to +2.7 10 YNL12S10025
9.6 to 14 +3.3 +3 to +3.6 10 YNL12S10033
9.6 to 14 +5 +4.5 to +5.5 10 YNL12S10050
Y-Series Surface-Mount POL Converters (continued)
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
2”x 4” and 3”x 5” Footprint Products
37
An Industry-Leading Array of Feature-Rich Solutions
BLP30 and SBLP65 Provide Industry-Leading2" x 4" Footprint Currents• Single output models available with outputs from 3.3 to 48V.• Triple output models with outputs ranging from 3.3 to 24V.• Extremely low-profile component heights (less than 1U) reduce
airflow shadowing to increase cooling for downstream devices.• Advanced thermal management techniques facilitate delivery of
full-rated power with minimal cooling.
3” X 5” PLP75 Offers Excellent EMC Immunity• Single and triple output models available.• High efficiencies and advanced thermal management techniques
facilitate delivering full-rated power with only 5 CFM forced-aircooling, and 65 watts with only convection cooling.
• Low profiles, 1.38" (35.1 mm), reduce airflow shadowing;increasing cooling airflow for downstream devices.
• Excellent EMC immunity; meets EN 61000 standards for ESD,RF susceptibility, fast transient/burst, surge, RF immunity,magnetic fields, and voltage interruptions.
High Power Density MPB125 and MPB150• High power densities; 125 and 150 watts in compact
3” x 5” footprint, low-profile packages.• As little as 5 CFM cooling airflow needed for full
power operation.• Rugged designs provide industry-leading MTBFs in
excess of 1M hours, based on field data.• Dual, triple, and quad output models are available.• Robust input transient/ESD protection; compliance to
EN61000-4-2/-3/-4/-5.
BLP40 and BLP55 3” X 5” Power Supplies are Ideal for 1U “Pizza Box” Applications• An extensive selection of low-profile single and triple
output models are available.• Advanced thermal-management techniques to deliver
full rated power with only 10 CFM cooling.• Reduced airflow requirements facilitate greater overall
system layout flexibility.• Standard features include remote sense, internal
overvoltage protection, and 85-264 VAC wide-range input.
BLP30
PLP75
BLP55
MPB125
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
38
MPB80/MPB1255.00 x 3.00 inch127.0 x 76.2 mm
• MPB80: 1.40 inch height• MPB125: 1.25 inch height• Input Transient & ESD
Compliant to EN61000-4-2/-3/-4
MAP110/MAP140
MAP30/40/42
BLP30
FXC6000/700015.17 x 8 x 5 inch
38.5 x 20.3 x 12.7 cm
5.00 x 3.00 x 1.16 inch127.0 x 76.2 x 40.6 mm
MAP556.00 x 3.27 x 1.60 inch52.4 x 83.1 x 40.6 mm
MAP807.20 x 4.20 x 1.80 inch
182.9 x 106.7 x 45.7 mm
MAP1308.50 x 4.50 x 2.00 inch
215.9 x 114.3 x 50.8 mm
7.00 x 4.30 x 1.80 inch177.8 x 109.2 x 45.7 mm
4 x 2 x 1.1 inch101.6 x 50.8 x 27.9 mm
• Only 10 CFM Cooling Required
BLP40/BLP555.00 x 3.00 x 1.07 inch127.0 x 76.2 x 27.2 mm
• Remote Sense
• Three-Phase AC Input• 230/480 VAC Operation
• CE Marked to the LowVoltage Directive
• Remote Sense on MainOutputs
• Optional L-Bracket & Cover
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
3.3 and 5Vout3.3 3 to 3.6 15 85 to 264 50 PLP75-1003
3.3 3.1 to 3.5 50 85 to 264 165 PFC250-1003
3.3 3.2 to 3.6 17 90 to 264 56 SBLP65-1003
5 N/A 6 90 to 264 30 BLP30-1005
5 4.7 to 5.8 6 90 to 264 30 MAP30-1005
5 4.7 to 5.5 8 90 to 264 40 MAP40-1005
5 4.8 to 5.5 8 85 to 264 40 BLP40-1005
5 4.7 to 5.8 11 85 to 264 55 MAP42-1005
5 4.8 to 5.5 11 85 to 264 55 BLP55-1005
5 4.8 to 5.5 13 90 to 264 65 SBLP65-1005
5 4.5 to 5.5 15 85 to 264 75 PLP75-1005
5 4.5 to 5.6 16 90 to 264 80 MAP80-1005
5 5.0 to 5.5 22 85 to 264 110 MAP110-1005
5 4.8 to 5.5 26 90 to 264 130 MAP130-1005
5 4.5 to 5.5 50 85 to 264 250 PFC250-1005
12 and 15Vout12 N/A 2.5 90 to 264 30 BLP30-1012
12 11.4 to 13.2 3.3 85 to 264 40 BLP40-1012
12 11 to 18 3.4 85 to 264 55 MAP42-1012
12 11.4 to 13.2 4.5 85 to 264 55 BLP55-1012
12 11.4 to 15.8 5 90 to 264 60 MAP55-1012
12 11.4 to 13.2 5.4 90 to 264 65 SBLP65-1012
12 10.8 to 13.2 6.5 85 to 264 75 PLP75-1012
12 11.5 to 15.5 7.5 90 to 264 80 MAP80-1012
12 11 to 13 8.4 85 to 264 100 MPB80-1012
12 11.2 to 15.8 10 85 to 264 110 MAP110-1012
12 11.8 to 12.2 10.5 90 to 264 125 MPB125-1012
12 11.4 to 15.8 12 90 to 264 130 MAP130-1012
12 11 to 16 12.5 85 to 264 150 MAP140-1012
12 11.6 to 16 17 85 to 264 200 MPU200-1012
12 10.8 to 13.5 21 85 to 264 250 PFC250-1012
12 10.8 to 13.5 30 85 to 264 375 PFC375-1012
15 14.3 to 16.5 4.3 90 to 264 65 SBLP65-1015
15 13.5 to 18.3 17 85 to 264 250 PFC250-1015
15 12 to 17 25 85 to 264 375 PFC375-1015
AC-DC > Single Output
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
39
Alpha-sorted graphics anddimensions augment modellistings from both pages.
PLP75
PFC250
PFC375/PFC500
8.00 x 4.20 x 1.50 inch203 x 107 x 38 mm
MPU200
• Power Factor CorrectionMeets EN61000-3-2
• Remote Sense on QuadModel Outputs V1 and V2
• Current Share, Power Fail,and Power Good Signals
• Power Factor Correction(PFC) Meets EN61000-3-2
• Fully-Regulated Outputs• Current Share; Power Fail
and Power Good Signals• Overtemperature,
Overvoltage, andOvercurrent Protected
• Power Factor Correction(PFC) Meets EN61000-3-2
• Single Wire Current Senseand Remote Sense on V1 &V2 Outputs
• Overtemperature,Overvoltage, andOvercurrent Protected
5.00 x 3.00 x 1.25 inch127.0 x 76.2 x 31.8 mm
8.50 x 4.75 x 2.00 inch215.9 x 120.7 x 50.8 mm
9.00 x 5.00 x 2.50 inch228.6 x 127.0 x 63.5 mm
SBLP65
• 2" x 4" x 1.3" standard footprint• High efficiency, 85% nominal• 65 W forced air & 60 W
convection rating• EMI conducted class B
4.00 x 2.00 x 1.30 inch101.6 x 50.8 x 33.0 mm
• 80% Typical Efficiency w/PFC• Single & Triple Output Models• Only 5 CFM Cooling Required
for 75 W• 65 W Convection Rating
NHC300012.25 x 5 x 5 inch
31.1 x 12.7 x 12.7 cm
• Single-Phase AC Input• 3U Height Configuration• Active Current Share• Power Factor Correction
Meets EN61000-3-2
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
24 and 28Vout24 N/A 1.3 90 to 264 30 BLP30-1024
24 23 to 29 1.7 85 to 264 40 MAP42-1024
24 22.8 to 26.4 1.8 85 to 264 40 BLP40-1024
24 22.8 to 26.4 2.3 85 to 264 55 BLP55-1024
24 23.5 to 28.5 2.5 90 to 264 55 MAP55-1024
24 22.8 to 26.4 2.7 90 to 264 65 SBLP65-1024
24 21.6 to 26.4 3.5 85 to 264 75 PLP75-1024
24 23 to 29 3.8 90 to 264 80 MAP80-1024
24 22 to 26 4.2 85 to 264 100 MPB80-1024
24 22.8 to 29.2 5 85 to 264 110 MAP110-1024
24 22.5 to 30 6.2 90 to 264 130 MAP130-1024
24 22.8 to 29.2 6.3 85 to 264 150 MAP140-1024
24 22.8 to 29.2 8.3 85 to 264 200 MPU200-1024
24 21.6 to 26.4 10.5 85 to 264 250 PFC250-1024
24 21.6 to 26.4 15 85 to 264 375 PFC375-1024
24 21.6 to 26.4 21 85 to 264 500 PFC500-1024
24 180 to 264 125 180 to 264 3000 NHC3011-5
28 25.2 to 30.8 13.4 85 to 264 375 PFC375-1028
28 25.2 to 30.8 17.9 85 to 264 500 PFC500-1028
28 25.2 to 30.8 107 180 to 264 3000 NHC3011-6
48Vout48 45.6 to 52.8 1.35 90 to 264 65 SBLP65-1048
48 43.2 to 52.8 1.8 85 to 264 75 PLP75-1048
48 46 to 50 2.1 85 to 264 100 MPB80-1048
48 45.8 to 54 3.1 85 to 264 150 MAP140-1048
48 45 to 56 4.2 85 to 264 200 MPU200-1048
48 46 to 56 6 85 to 264 250 PFC250-1048
48 46 to 56 7.8 85 to 264 375 PFC375-1048
48 46 to 56 10.4 85 to 264 500 PFC500-1048
48 43.2 to 52.8 62.5 180 to 264 3000 NHC3021-8
48 45.6 to 50.4 125 180 to 528 6000 FXC6000-48-S
48 45.6 to 50.4 145 180 to 528 7000 FXC7000-48-S
AC-DC > Single Output
Additional single-output products are described in the Hot-Swap Front-End andModular Solutions sections.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
40
MPB805.00 x 3.00 x 1.40 inch127.0 x 76.2 x 35.6 mm
• Wide Input Range for110/220 VAC Applications
BLP40/BLP555.00 x 3.00 x 1.07 inch127.0 x 76.2 x 27.2 mm
• Only 10 CFM Cooling Required
• Universal input 85-264 VAC
• Remote Sense on MainOutputs
MAP405.00 x 3.00 x 1.16 inch127.0 x 76.2 x 40.6 mm
MAP1407.00 x 4.30 x 1.80 inch
177.8 x 109.2 x 45.7 mm
AC-DC > Triple Output
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
+5 4.7 to 5.8 15 85 to 264 80 MPB80-2000+12 N/A 1
+5 N/A 25 90 to 264 125 MPB125-2005+12 N/A 0.5
+12 N/A 10.5 90 to 264 125 MPB125-201212 N/A 0.5
+12 N/A 12.5 90 to 264 150 MPB150-201212 N/A 0.5
+15 N/A 8.3 90 to 264 125 MPB125-201512 N/A 0.5
+24 N/A 5.2 90 to 264 125 MPB125-202412 N/A 0.5
+24 N/A 6 90 to 264 150 MPB150-202412 N/A 0.5
+48 N/A 2.6 90 to 264 125 MPB125-204812 N/A 0.5
+48 N/A 3.1 90 to 264 150 MPB150-204812 N/A 0.5
48 N/A 8 85 to 264 400 PALS400-248212 N/A 16
48 N/A 9 85 to 264 600 PALS600-248212 N/A 16
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
One 3.3V, One 5V, and One 12V Output+3.3 N/A 5 85 to 264 37 BLP55-3300+5 N/A 2.5+12 N/A 0.7
+3.3 3.2 to 3.6 7 90 to 264 50 SBLP65-3300+5 N/A 3.5+12 N/A 0.5
+3.3 3 to 3.6 8 85 to 264 75 PLP75-3300+5 N/A 4+12 N/A 1
+3.3 3.1 to 3.9 8.5 85 to 264 80 MPB80-3300+5 4.7 to 5.8 5+12 N/A 0.7
+3.3 3.1 to 3.8 35 85 to 264 150 MPU150-3300+5 5 to 5.5 20+12 N/A 2
Continued on Next Page
BLP304 x 2 x 1.1 inch
101.6 x 50.8 x 27.9 mm
• 30 W Output Power• Only 10 CFM Cooling Required
AC-DC > Dual Output
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
41
Alpha-sorted graphics anddimensions augment modellistings from both pages.
MPB125/MPB1505.00 x 3.00 x 1.25 inch127.0 x 76.2 x 31.8 mm
• High Power Density in anIndustry-Standard 3” x 5”Footprint
PLP755.00 x 3.00 x 1.25 inch127.0 x 76.2 x 31.8 mm
• 80% Typical Efficiency withPower Factor Correction
PALS400/PALS600
10.40 x 4.00 x 1.59 inch264.2 x 101.6 x 40.4 mm
• Dedicated Power-over-Ethernet Power Supplies
MPU1508.00 x 4.20 x 1.50 inch
203.2 x 106.7 x 38.1 mm
• Power Factor CorrectionMeets EN61000-3-2
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
One 3.3V and Two 12V Outputs+3.3 3 to 3.6 8 85 to 264 75 PLP75-3301+12 N/A 4-12 N/A 1
Two 5V and One 12V Output+5 4.7 to 5.8 3 90 to 264 40 MAP40-3105-5 N/A 0.5+12 N/A 2
One 5V and Two 12V Outputs (Sorted by Watts)+5 N/A 3.5 90 to 264 30 BLP30-3000+12 N/A 2-12 N/A 0.5
+5 4.8 to 5.5 4 85 to 264 40 BLP40-3000+12 N/A 2-12 N/A 0.7
+5 4.8 to 5.5 3 90 to 264 40 MAP40-3000+12 N/A 2-12 N/A 0.3
+5 4.8 to 5.2 3 90 to 264 40 MAP40-3100+12 N/A 2-12 N/A 0.3
+5 4.7 to 5.8 5 90 to 264 40 MAP40-3500+12 N/A 1-12 N/A 0.3
+5 N/A 5 85 to 264 55 BLP55-3000+12 N/A 2.5-12 N/A 0.7
+5 4.8 to 5.5 7 90 to 264 65 SBLP65-3000+12 N/A 2.5-12 N/A 0.5
+5 4.5 to 5.5 8 85 to 264 75 PLP75-3000+12 N/A 4-12 N/A 1
+5 4.7 to 5.8 8.5 85 to 264 80 MPB80-3000+12 N/A 3-12 N/A 0.7
+5 N/A 16.5 90 to 264 125 MPB125-3000+12 N/A 5-12 N/A 0.5
+5 4.8 to 5.2 20 85 to 264 140 MAP140-3000P+12 N/A 4-12 N/A 1
Continued on Next Page
AC-DC > Triple Output
See PoE Section for more details
SBLP65
• 2"x4"x1.3" standard footprint• High efficiency, 85% nominal
4.00 x 2.00 x 1.30 inch101.6 x 50.8 x 33.0 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Chassis Mount> AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
42
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
One 5V and Two 15V Outputs+5 4.8 to 5.5 4 85 to 264 40 BLP40-3003+15 N/A 2-15 N/A 0.7
+5 4.7 to 5.8 3 90 to 264 40 MAP40-3003+15 N/A 1.5-15 N/A 0.2
+5 4.8 to 5.5 7 90 to 264 65 SBLP65-3003+15 N/A 2.5-15 N/A 0.5
+5 4.8 to 5.5 8 85 to 264 75 PLP75-3003+15 N/A 3.2-15 N/A 1
One 5V, One 12V, and One 24V Output+5 4.8 to 5.2 3 90 to 264 40 MAP40-3101+24 N/A 0.3-12 N/A 1
+5 4.8 to 5.5 7 90 to 264 65 SBLP65-3001+24 N/A 1.5-12 N/A 0.5
+5 4.5 to 5.5 8 85 to 264 75 PLP75-3001+24 N/A 2.6-12 N/A 1
+5 5 to 5.5 17.5 85 to 264 150 MPU150-3524+12 10.8 to 13.2 4+24 N/A 2
AC-DC > Triple Output
BLP405.00 x 3.00 x 1.07 inch127.0 x 76.2 x 27.2 mm
• Only 10 CFM Cooling Required
• Universal input 85-264 VAC
MAP405.00 x 3.00 x 1.16 inch127.0 x 76.2 x 40.6 mm
PLP755.00 x 3.00 x 1.25 inch127.0 x 76.2 x 31.8 mm
• 80% Typical Efficiency withPower Factor Correction
MPU1508.00 x 4.20 x 1.50 inch
203.2 x 106.7 x 38.1 mm
• Power Factor CorrectionMeets EN61000-3-2
SBLP65
• 2"x4"x1.3" standard footprint• High efficiency, 85% nominal
4.00 x 2.00 x 1.30 inch101.6 x 50.8 x 33.0 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
43
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
Under 100 Watts
+5 4.7 to 5.6 6 90 to 264 55 MAP55-4000+12 N/A 3-5 N/A 0.5-12 N/A 0.5
+5 4.7 to 5.6 6 90 to 264 55 MAP55-4002+12 N/A 3-12 N/A 0.5+12 N/A 0.5
+5 4.7 to 5.6 6 90 to 264 55 MAP55-4003+15 N/A 2.5-5 N/A 0.5-15 N/A 0.5
+5 4.7 to 5.6 6 90 to 264 55 MAP55-4001+24 N/A 1.5-12 N/A 0.5+12 N/A 0.5
+5 4.7 to 5.6 6 90 to 264 55 MAP55-4004+24 N/A 1.5-15 N/A 0.5+15 N/A 0.5
+5 4.8 to 5.5 14 90 to 264 80 MAP80-4000+12 11.5 to 12.5 4-5 N/A 1-12 N/A 1
+5 4.8 to 5.5 14 90 to 264 80 MAP80-4010+12 11.5 to 12.5 4-5 N/A 1-12 N/A 3
+5 4.8 to 5.5 14 90 to 264 80 MAP80-4020+12 11.5 to 12.5 4-12 N/A 1-5 N/A 3
+5 4.7 to 5.5 14 90 to 264 80 MAP80-4002+12 11.5 to 12.5 4-12 N/A 1+12 N/A 1
+5 4.8 to 5.5 14 90 to 264 80 MAP80-4003+15 14.4 to 15.8 3.5-5 N/A 1-15 N/A 1
+5 4.8 to 5.5 14 90 to 264 80 MAP80-4001+24 23 to 25 2-12 N/A 1+12 N/A 1
+5 4.8 to 5.5 14 90 to 264 80 MAP80-4004+24 23 to 25 2-15 N/A 1+15 N/A 1
Continued on Next Page
MAP807.20 x 4.20 x 1.80 inch
182.9 x 106.7 x 45.7 mm
MAP556.00 x 3.27 x 1.60 inch152.4 x 83.1 x 40.6 mm
• Metric & SAE MountingInserts
• Universal Input 90-264 VAC• Optional Cover• Dual-Mode Connectors
• Metric & SAE MountingInserts
• Universal Input 90-264 VAC• Optional Cover• Power Fail Signal• Dual-Mode Connectors
AC-DC > Quad Output
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
44
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
110 to 125 Watts
+3.3 3.2 to 3.4 15 85 to 264 110 MAP110-4300+5 N/A 8-12 N/A 1+12 N/A 1
+5 4.8 to 5.2 12 85 to 264 110 MAP110-4000+12 N/A 5-12 N/A 1-5 N/A 1
+5 4.8 to 5.2 12 85 to 264 110 MAP110-4002+12 N/A 5-12 N/A 1+12 N/A 1
+5 4.8 to 5.2 12 85 to 264 110 MAP110-4011+12 N/A 5-12 N/A 1+24 N/A 1
+5 4.8 to 5.2 12 85 to 264 110 MAP110-4003+15 N/A 5-15 N/A 1-5 N/A 1
+5 4.8 to 5.2 12 85 to 264 110 MAP110-4001+24 N/A 3-12 N/A 1+12 N/A 1
+5 4.8 to 5.2 12 85 to 264 110 MAP110-4004+24 N/A 3-15 N/A 1+15 N/A 1
+12 11.6 to 12.4 5 85 to 264 110 MAP110-4200+24 N/A 4-12 N/A 1+5 N/A 2
+2.5 N/A 12 90 to 264 125 MPB125-4250+5 N/A 15+12 N/A 5-12 N/A 0.5
+3.3 N/A 10 90 to 264 125 MPB125-4350+5 N/A 15+12 N/A 5-12 N/A 0.5
130 to 150 Watts
+5 4.8 to 5.5 20 90 to 264 130 MAP130-4000+12 11.5 to 12.5 5-5 N/A 1-12 N/A 1
+5 4.8 to 5.5 20 90 to 264 130 MAP130-4002+12 11.5 to 12.5 5-12 N/A 1+12 N/A 1
MAP1308.50 x 4.50 x 2.00 inch
215.9 x 114.3 x 50.8 mm
• Metric & SAE MountingInserts
• Power Fail Signal• Dual-Mode Connectors
AC-DC > Quad Output
MAP1107.00 x 4.30 x 1.80 inch
177.8 x 109.2 x 45.7 mm
• Remote Sense on MainOutputs
• Optional L-Bracket & Cover• Optional Power Fail and
Thermal Shutdown
MPB1255.00 x 3.00 x 1.25 inch127.0 x 76.2 x 31.8 mm
• High Power Density inIndustry Standard 3” x 5”Footprint
• Power Factor CorrectionMeets EN61000-3-2
• Main Output Remote Sense• Input Transient & ESD
Compliance to EN61000-4-2/-3/-4
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
45
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
130 to 150 Watts (Continued)+5 4.8 to 5.5 20 90 to 264 130 MAP130-4010+12 N/A 5-5 N/A 1-12 N/A 3
+5 4.8 to 5.5 20 90 to 264 130 MAP130-4020+12 N/A 5-12 N/A 1-5 N/A 3
+5 4.8 to 5.5 20 90 to 264 130 MAP130-4003+15 14 to 16 4-5 N/A 1-15 N/A 1
+5 4.8 to 5.5 20 90 to 264 130 MAP130-4001+24 23 to 25 3.5-12 N/A 1+12 N/A 1
+5 4.8 to 5.5 20 90 to 264 130 MAP130-4004+24 23 to 25 3.5-15 N/A 1+15 N/A 1
+3.3 3.1 to 3.6 30 85 to 264 150 MPU150-4350+5 5 to 5.5 1512 10.8 to 13.2 312 10.8 to 13.2 3
+5 5 to 5.5 30 85 to 264 150 MPU150-4530+3.3 3.1 to 3.6 1512 10.8 to 13.2 312 10.8 to 13.2 3
+5 5 to 5.5 30 85 to 264 150 MPU150-4000+12 10.8 to 13.2 812 10.8 to 13.2 35 5 to 5.5 2
200 to 250 Watts+3.3 3.3 to 3.8 50 85 to 264 240 NET1-4230+5 N/A 5+12 N/A 4+2.5 2.5 to 3 50
+3.3 3.3 to 3.8 50 85 to 264 240 NET1-4350+12 N/A 4+12 N/A 4+5 5 to 5.5 30
+3.3 3.1 to 3.5 40 85 to 264 250 PFC250-4350+5 5 to 5.5 2012 10.8 to 13.2 612 10.8 to 13.2 3
+5 5 to 5.5 30 85 to 264 200 MPU200-4530+3.3 3.1 to 3.6 1512 10.8 to 13.2 812 10.8 to 13.2 4
Continued on Next Page
PFC2508.50 x 4.75 x 2.00 inch
215.9 x 120.7 x 50.8 mm
NET17.00 x 4.50 x 1.35 inch
177.8 x 114.3 x 34.3 mm
• Next-generation PatentedDesign Provides ExtremelyHigh Efficiencies andCurrent Densities
• Power Factor CorrectionMeets EN61000-3-2
• Single Wire Current Senseand Remote Sense on V1 &V2 Outputs
MPU200
8.00 x 4.20 x 1.50 inch203 x 107 x 38 mm
• Power Factor CorrectionMeets EN61000-3-2
• Remote Sense on QuadModel V1 and V2 Outputs
AC-DC > Quad Output
Alpha-sorted graphics anddimensions augment modellistings from both pages.
MPU1508.00 x 4.20 x 1.50 inch
203 x 107 x 38 mm
• Power Factor CorrectionMeets EN61000-3-2
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Chassis Mount > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
46
Factory Vout Max Input MaxSet Vout Trim Range Amps VAC Watts Model
200 to 250 Watts (Continued)
+5 5 to 5.5 40 85 to 264 250 PFC250-4530+3.3 3.1 to 3.5 2012 10.8 to 13.2 612 10.8 to 13.2 3+5 5 to 5.5 40 85 to 264 250 PFC250-4000+12 10.8 to 13.2 1012 10.8 to 13.2 65 5 to 5.5 3
+5 5 to 5.5 40 85 to 264 250 PFC250-4001+12 10.8 to 13.2 1012 10.8 to 13.2 612 10.8 to 13.2 3
375 to 400 Watts
+5 4.5 to 5.5 40 85 to 264 375 PFC375-4000+12 11.3 to 12.6 1012 11.3 to 12.6 65 N/A 3
+5 4.5 to 5.5 40 85 to 264 375 PFC375-4002+12 11.3 to 12.6 1012 11.3 to 12.6 624 22 to 28 3
+24 21.5 to 26.4 10 85 to 264 375 PFC375-4200+5 4.5 to 5.5 1012 11.4 to 12.6 412 11.4 to 12.6 4
+24 21.5 to 26.4 10 85 to 264 375 PFC375-4201+5 4.5 to 5.5 1015 14.2 to 16 415 13.7 to 16 4
+3.3 3.2 to 3.4 55 85 to 264 400 NET2-435012 11.4 to 12.6 512 11.4 to 12.6 5+5 4.9 to 5.2 40+5.2* N/A 2* * NET2-4350 V5out is a fixed 5.2V standby voltage at 2A.
Additional quad-output products are listed in the Modular Solutions sections.
PFC3759.00 x 5.00 x 2.50 inch
228.6 x 127.0 x 63.5 mm
8.25 x 4.50 x 1.59 inch209.6 x 114.3 x 40.4 mm
NET2
• Power Factor CorrectionMeets EN61000-3-2
• Main Output Remote Sense• Current Share, Power Fail,
and Power Good Signals• Overtemperature, Overload,
and Overvoltage Protection• Input Transient & ESD
Compliance to EN61000-4-2/-3/-4
• Power Factor CorrectionMeets EN61000-3-2
• Isolated V2 and V3 Outputs• Overtemperature, Overload,
and Overvoltage Protection• No Minimum Load
Requirement
AC-DC > Quad Output
PFC2508.50 x 4.75 x 2.00 inch
215.9 x 120.7 x 50.8 mm
• Power Factor CorrectionMeets EN61000-3-2
• Single Wire Current Senseand Remote Sense on V1 &V2 Outputs
• Overtemperature, Overload,and Overvoltage Protection
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Chassis Mount > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
47
MDU1508.00 x 4.20 x 1.50 inch
203.2 x 106.7 x 38.1 mm
MDU200
PDC500
8.00 x 4.20 x 1.50 inch203.2 x 106.7 x 38.1 mm
9.00 x 5.00 x 2.50 inch228.6 x 127.0 x 63.5 mm
Input Factory Vout Max MaxVDC Set Vout Trim Range Amps Watts Model
Single-Output Models36 to 75 12 11.6 to 16 17 200 MDU200-101236 to 75 24 22.8 to 29.2 8.3 200 MDU200-102436 to 75 24 21.6 to 26.4 21 500 PDC500-102436 to 75 48 45 to 56 4.2 200 MDU200-1048
Triple-Output Models36 to 72 +3.3 3.1 to 3.8 35 150 MDU150-3300
+5 5 to 5.5 20+12 N/A 2
Quad-Output Models36 to 75 +2.5 2.25 to 3.0 30 150 MDU150-4230
+3.3 3.15 to 3.8 1512 10.8 to 13.2 35 5 to 5.5 2
36 to 75 +3.3 3.15 to 3.8 30 150 MDU150-4350+5 5 to 5.5 1512 10.8 to 13.2 312 10.8 to 13.2 3
36 to 75 +5 5 to 5.5 30 150 MDU150-4530+3.3 3.15 to 3.8 15
12 10.8 to 13.2 312 10.8 to 13.2 3
36 to 75 +5 5 to 5.5 30 150 MDU150-4000+12 10.8 to 13.2 812 10.8 to 13.2 3
5 5 to 5.5 2
DC-DC > Single, Triple, & Quad Output
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Modular Power Solutions > ESP/ESM
48
The ESP4 and ESP6 Series are extremely flexible modular products that are ideal multiple-output power solutions for a wide range of applications. The UL2601-1 and EN60601-1compliant ESM4 and ESM6 Series combine low leakage currents (under 300 µA) with IEC601-1 isolation and spacing, making them ideal platforms for medical-diagnostic applications suchas MRI and CAT scanners, blood analyzers, and DNA sequencers.
The ESP4 and ESM4 Series are available in 400 and 600 watt configurations, both providing upto eight outputs from 2.56" x 5" x 10.63" (65 x 127 x 270 mm) chassis. The ESP6 and ESM6are available in 600 and 1000 watt versions, both providing up to twelve outputs from 2.56" x7.36" x 10.63" (65 x 187 x 270 mm) chassis. Five single-output and two dual-output modulescan be configured in series or parallel to provide outputs from 1.45 to 58 VDC.
Additional features include: wide-range input from 88 to 264 VAC, no minimum-load operation,an internal fan, and fully-isolated outputs. In addition, individual output modules have a PowerGood signal, Output Inhibit, and Remote Adjust. Standard options include input Power Fail,Global Enable or Inhibit, and a 5 V @ 50 mA bias supply. Regulatory agency compliancesinclude UL, cUL, EN61000-3-2 (PFC), Class B conducted emissions, and the EMC requirementsof EN61000-4-2, -3, -4, -5, -6, and -11.
Description
Features• 1 to 12 isolated outputs with full user configurability• 1.45 V to 28 V standard output voltages• Isolated bias supply voltage of 5 V @ 50 mA• Class B conducted emissions• 400, 600 and 1000 Watts of output power• Series and parallel capability• Zero-load operation• EN61000-3-2 compliant• Universal input• Fully-floating outputs• Individual control signals on each module• Modular construction• Industry-standard footprint• Compact packaging,
ESP4 and ESM4: 2.56 x 5.00 x 10.63 in(65 x 127 x 270 mm)
ESP6 and ESM6: 2.56 x 7.36 x 10.63 in(65 x 187 x 270 mm)
• 2-year warranty
Additional ESM Features• Medical Approvals• EN60601-1, UL2601-1, IEC601-1 approved• 12mm creepage• Low leakage current <300 µA• Class B conducted emissions (ESM6)
ESP4/ESM4
ESP6/ESM6
ESP Flexibility
Notes:Maximum current = (I1 + I2) x 0.9Use two parallel links
Notes:Maximum voltage to chassis is 500 VUse series linkReverse bias diodes may be required for certain applications,e.g., large capacitive loads
A user-friendly modular product configuratoris available at www.power-one.com
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Modular Power Solutions > ESP/ESM
49
Use 00 if no optionsare desired.
Use 0 for unfilled slots
E S P 4 C 1 2 2 5 0 7 —
Single-Output Module Selection
Module No. of Slots Nominal Voltage Range Imax
Module 1 1 5V 3 to 5.6V 30A
Module 2 1 12V 5 to 13V 20A
Module 3 1 18V 8 to 20V 15A
Module 4 1 24V 12 to 28V 12A
Module 70 2 5V 1.45 to 5.6V 80A
Dual-Output Module Selection
Module No. of Slots Nominal Voltage Range Imax
Module 5 1 24V 10 to 28V 3A24V 10 to 28V 3A
Module 6 1 5V 3 to 5.6V 10A1 24V 10 to 28V 3A ESP/ESM Standard Options
06 Mains Power Fail + Global Enable + Bias Supply Voltage07 Mains Power Fail + Global Inhibit + Bias Supply Voltage
Output Signals
Output control signals are available on all output modules.(see application note)
Modules 1 to 6 Module 70 Additional Features• Power good signal • Adjustable Current Limit• Output inhibit signal • Foldback or Straight Line Current
Limiting• Remote adjust (margin) • Bias Voltage
• Selectable Output Inhibit or Enable
Dual output modules: Output signals available on first [top] output only.
How to Order ESP4 or ESM4 (ESP4 shown in example)(Available in 400/600 Watt Versions)
Note: Calculate powerrequirements by summingoutput powers calculated atapplication output voltages.
Note: Calculate powerrequirements by summingoutput powers calculated atapplication output voltages.
For ESP/ESM6D:Limit total power from slotsA-C and D-F to 550 W each.
How to Order ESM6 or ESP6 (Available in 600/1000 Watt Versions)
Series
Power B = 400 WC = 600 W
C = 600 WD = 1000 W
Slot A
Slot B Slot C
Slot D
Number of slotsOption code
— = standard configurationC = special configuration
Use 00 if no optionsare desired.
E S M 6 D 1 2 2 4 0 7 —
Series
Power
Slot A
Slot B Slot C
Slot D
Slot E
Slot FNumber of slots
Option code
— = standard configurationC = special configuration
}
}
Specifications of ESP4 part number example:• 4-slot series• Maximum output power: 600 W• 5V @ 30A; 12V @ 20A; 24V @ 3A; 24V @ 3A• Mains Power Fail signal + Logic Inhibit + Bias Supply Voltage
Specifications of ESM6 part number example:• 6-slot series• Maximum output power: 1000 W• 5V @ 30A; 12V @ 20A; 12V @ 20A; 24V @ 12A; 24V @ 12A; 24V @ 3A; 24V @ 3A• Mains Power Fail signal + Logic Inhibit + Bias Supply Voltage
Production Configuration:Units are shipped with nominal output voltages unless specialconfiguration is specified. Power-One can configure to your exactrequirements through use of appropriate series and parallel busbars,and voltage adjustment to specific set points.
4 5
Use 0 for unfilled slots
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Modular Power Solutions > High Power
50
Modular High Power Series Chassis Overview
CHASSISMETRIC MOUNTING SMF3 HMF3 HMF5 SMM3 SMM5 HMM5 RMF5 RMM5STANDARD SPF3 HPF3 HPF5 SPM3 SPM5 HPM5 RPF5 RPM5
OUTPUT POWER AND POWER FACTOR
.99 PFC to meet EN60555 YES YES YES N/A N/A N/A YES N/A
Max output wattage at high range line input 1350 2000 2000 1000 1500 2000 3000 4000
Max output wattage at low range line input* 1000 1500 1500 1000 1500 N/A N/A N/A
INPUT VOLTAGE SPECIFICATIONS
High range VAC input 160-264 160-264 160-264 175-264 175-264 180-264 160-264 180-264
Low range VAC input 85-159 85-159 85-159 90-132 90-132 N/A N/A N/A
VAC input selection Wide Range Wide Range Wide Range Manual Manual N/A N/A N/A
VAC input phases Single Single Single Single Single Single Single Three
OUTPUT MODULE SPECIFICATIONS
Max # of outputs 9 9 15 9 15 15 15 15
# of module slots 3 3 5 3 5 5 5 5
MECHANICAL SPECIFICATIONS
Chassis size H x W x L, inches 5 x 5.5 x 12.5 5 x 5.5 x12.5 5 x 8 x 11 5 x 5.5 x 11 5 x 8 x 11 5 x 8 x 11 5 x 8 x 12.5 5 x 8 x 15
Chassis size H x W, millimeters 127 x 140 127 x 140 127 x 203 127 x 140 127 x 203 127 x 203 127 x 203 127 x 203
Chassis size x L, millimeters x 318 x 318 x 280 x 280 x 280 x 280 x 318 x 381
INPUT TRANSIENT PROTECTION SPECIFICATIONS
ESD Immunity Level 4 Level 4 Level 4 Level 4 Level 4 Level 4 Level 4 Level 4EN61000-4-2, 15kV/8kV 15kV/8kV 15kV/8kV 15kV/8kV 15kV/8kV 15kV/8kV 15kV/8kV 15kV/8kV
RF Susceptibility Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 Level 3EN61000-4-3 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m
Fast Transient/Burst Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 Level 3EN61000-4-4 +2kV +2kV +2kV +2kV +2kV +2kV +2kV +2kV
Surge Immunity Class 4 Class 4 Class 4 Class 4 Class 4 Class 4 Class 4 Class 4EN61000-4-5 (Line-Line) 2kV 2kV 2kV 2kV 2kV 2kV 2kV 2kV
Surge Immunity Class 4 Class 4 Class 4 Class 4 Class 4 Class 4 Class 4 Class 4EN61000-4-5 (line-Gnd) 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV
*Maximum wattage above 100 VAC input for SPF/HPF
Power-One’s high power modular products can provide up to 21 outputs in over 10 millionvoltage and current combinations. Eighteen chassis are available from 1000 to 4000 watts;including power factor corrected and three-phase input. Over 90 output modules areavailable to provide voltages from 1 to 48 VDC.
High-Power Modular ProductsUp to 21 Outputs, from 1 to 48 VDC
RELIABILITY• Demonstrated DC output module MTBF of
greater than 5 million hours.• Ruggedized AC input sections incorporate
extensive transient protection.• Vibration tested at 6 GRMS, 3 axis,
10 to 2000 Hz.• Two-year warranty.
FLEXIBILITY• Modular construction; over 10 million
configurations available.• Up to 21 outputs per power supply from
1.0 to 48 VDC.• Parallelable outputs• System inhibit and individual module
output inhibit capability.
PERFORMANCE• Most outputs fully regulated and isolated.• Active PFC models meet EN61000-3-2 and
EN60555-2.• EN60950/UL1950 approved. CE Marked to
the Low Voltage Directive.• No minimum loads required on most
outputs.
A user-friendly modular product configurator is available at www.power-one.com
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Modular Power Solutions > High Power
51
Model(1500 W Max)
5V @150A
12V @20A
-12V @20A
Option Code
Single Slot Bank
CONFIGURATION NOTES• Modules are designated in left to right in the part number but are
installed right to left in the chassis.• Single and double wide modules occupy one and two chassis
slots, respectively. Confirm that the total number of slots requireddoes not exceed the chassis slot capacity.
• Not all modules can be used in all slots. Refer to thecompatibility table below.
• Fill blank slots with K or L option.
EXAMPLE: OUTPUTS SELECTED 5V @ 150A12V @ 20A
–12V @ 20A
STANDARD OPTIONSSYSTEM INHIBIT (OPT A, B & C)
POWER OUTPUT
OPTION INHIBIT ENABLE
Std Logic Low Open Ckt. or Logic High
A Logic High Open Ckt. or Logic Low
B Open Ckt. Logic Lowor Logic High
C Open Ckt. Logic Highor Logic Low
OPTION SIGNAL OUTPUT
Std Hi To Lo Transition
M Lo To Hi Transition
MODULE AND CHASSIS COMPATIBILITYConfirm that the number listed in the compatibility column of the moduleselector guide is equal to or less than the lowest number specified for themodule slots pictured below. Example: The SPF3 can only use moduleswith a slot compatibility of 1 in the slot closest to the input section, but can
use any module with a compatibility number of 4 or less in the two otherslots. Bold lines designate adjoining slots that can be used for double widemodules.
HPF5/HMF5/RPF5/RMF5
SPM5/SMM5/HPM5/HMM5
SPF3/SMF3/HPF3/HMF3 RPM5/RMM5
SPM3/SMM3
OPTION SIGNAL OUTPUT
Open CollectorN Conducts
To Give Signal
Open CollectorP Opens To
Give Signal
OTHER OPTIONS
DESCRIPTION
K – Single Width Slot Blank
L – Double Width Slot Blank
See Paralleled Module ConfigurationsFor Additional Options
INPUT POWER FAIL WARNING (OPT M, N & P)
All chassis slots are numbered inright-to-left sequence.
}
ParallelingSuffix
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Modular Power Solutions > High Power
52
SINGLE VOLTAGE OUTPUT MODULES (For Preset Voltage Information, Consult Factory)NOMINAL ADJUSTMENT CURRENT (AMPS) MODULE SLOTS SLOT NOISE & RIPPLE (mV PK-PK) OUTPUTVOLTAGE RANGE @ 50°C (NOTE A) USED COMPATIBILITY TYPICAL/MAX (NOTE B) CONNECTION
1.5V 1.5 - 1.8V 35 T1 1 1 30/50 Type II1.5V 1.5 - 1.8V 60 T6 1 1 30/50 Type I1.5V 1.5 - 1.8V 250 T4 2 2 30/50 Type III2V 1.8 - 2.2V 80 F8 1 3 25/40 Type I2V 2 - 2.2V 35 F1 1 1 20/50 Type II 2V 2 - 2.2V 60 AG (Note C) 1 1 30/50 Type I 2V 2 - 2.2V 60 F6 1 1 30/50 Type I 2V 2 - 2.2V 150 F2 2 2 30/50 Type III 2V 2 - 2.2V 180 CS 2 5 30/50 Type III 2V 2 - 2.2V 250 F4 2 2 30/50 Type III 2V 2 - 2.2V 320 F7 2 5 30/100 Type III
2.3V 2.07 - 2.53 35 BJ 1 1 30/50 Type II 3.3V 2.97 - 3.63 35 H1 1 1 30/50 Type II 3.3V 2.97 - 3.63 60 H6 1 1 30/50 Type I 3.3V 2.97 - 3.63 80 H8 1 3 40/50 Type I3.3V 2.97 - 3.63 90 DA 1 5 30/50 Type I 3.3V 2.97 - 3.63 150 H2 2 2 30/40 Type III 3.3V 2.97 - 3.63 250 H4 2 2 30/50 Type III 3.3V 2.97 - 3.63 320 H7 2 5 50/100 Type III5V 4.5 - 5.5 35 A1 1 1 35/50 Type II 5V 4.5 - 5.5 60 A6 1 1 15/50 Type I 5V 4.5 - 5.5 80 A8 1 3 15/50 Type I 5V 4.5 - 5.5 90 DT 1 5 15/50 Type I 5V 4.5 - 5.5 150 A2 2 2 30/50 Type III 5V 4.5 - 5.5 220/250 A4 (Note D) 2 3/4 30/50 Type III 5V 4.5 - 5.5 320 A7 2 5 30/100 Type III 5V 4.5 - 5.5 375 QA 2 5 30/50 Type III 6V 5.4 - 6.6 35 AU 1 1 65/90 Type II 6V 5.4 - 6.6 80 FD 1 3 30/60 Type I6V 5.4 - 6.6 100 CT 1 5 40/60 Type I 6V 5.4 - 6.6 120 BY 2 2 40/60 Type III 6V 5.4 - 6.6 250 CU 2 5 40/100 Type III 8V 7.2 - 8.8 160 FA 2 5 40/200 Type III8V 7.2 - 8.8 50 GM 1 4 40/60 Type I
8.5V 7.65 - 9.35 20 CF 1 1 50/75 Type II10V 9 - 11 20 AW 1 1 66/100 Type II 10V 9 - 11 40 BE 1 3 40/60 Type I 10V 9 - 11 50 CV 1 5 66/100 Type I 10V 9 - 11 160 CW 2 5 100/200 Type III 12V 10.8 - 13.2 20 B1 1 1 80/120 Type II 12V 10.8 - 13.2 40 B6 1 3 40/60 Type I 12V 10.8 - 13.2 50 B8 1 4 40/60 Type I12V 10.8 - 13.2 65 B2 2 2 80/120 Type III 12V 10.8 - 13.2 80 BC 2 3 80/120 Type III 12V 10.8 - 13.2 135 DE 2 5 120/240 Type III 15V 13.5 - 16.5 16 AF (Note E) 1 1 15/35 Type II 15V 13.5 - 16.5 16 C1 1 1 100/150 Type II 15V 13.5 - 16.5 33 C6 1 3 30/60 Type I 15V 13.5 - 16.5 50 C5 1 5 100/150 Type I 15V 13.5 - 16.5 52 C2 2 2 100/150 Type III 18V 16.2 - 19.8 44 GD 1 4 80/120 Type I24V 21.6 - 26.4 10 D1 1 1 160/240 Type II 24V 21.6 - 26.4 15 D6 1 2 80/120 Type II24V 21.6 - 26.4 29 D8 1 4 70/110 Type I 24V 21.6 - 26.4 33 D5 1 5 60/100 Type I24V 21.6 - 26.4 42 GH 1 5 50/100 Type I28V 25.2 - 30.8 8.6 E1 1 1 200/280 Type II 28V 25.2 - 30.8 13.5 E3 1 1 50/100 Type I28V 25.2 - 30.8 16 E7 (Note F) 1 1 50/100 Type I28V 25.2 - 30.8 26 E8 1 4 70/100 Type I
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Modular Power Solutions > High Power
53
WIDE-RANGE SINGLE OUTPUT, VARIABLE VOLTAGE MODULESNOMINAL ADJUSTMENT CURRENT (AMPS) MODULE SLOTS SLOT NOISE & RIPPLE (mV PK-PK) OUTPUTVOLTAGE RANGE @ 50°C (NOTE A) USED COMPATIBILITY TYPICAL/MAX (NOTE B) CONNECTION
1.0V 0.7 - 2.1V 320 ER 2 5 30/100 Type III2.0V 1.5 - 2.8V 375 QF (Note C) 2 5 50/50 Type III
1.9V to 3V 1.9V to 3V 150 AB 2 2 50/50 Type III3.3V 2.5V to 4V 375 QH 2 5 30/75 Type III
14V to 24V 14V to 24V 10 W1 1 1 80/120 Type II
DUAL VOLTAGE OUTPUT MODULESNOMINAL CURRENT (AMPS) MODULE SLOTS SLOT NOISE & RIPPLE (mV PK-PK) OUTPUTVOLTAGE @ 50°C (NOTE A) USED COMPATIBILITY TYPICAL/MAX (NOTE B) CONNECTION
12/12 10/4 M4 (Note G) 1 1 120/240 Type II±12 10/10 B4 (Note H) 1 1 120/240 Type II±15 8/8 C4 (Note H) 1 1 150/300 Type II±20 5/5 BQ (Note H) 1 1 80/100 Type II±24 5/5 D4 (Note H) 1 1 80/120 Type II
TRIPLE OUTPUT VOLTAGE MODULES (Note G)NOMINAL CURRENT (AMPS) MODULE SLOTS SLOT NOISE & RIPPLE (mV PK-PK) OUTPUTVOLTAGE @ 50°C (NOTE A) USED COMPATIBILITY MAXIMUM (NOTE B) CONNECTION
5/1.5/3.3 15/10/10 FC 1 1 100/100/100 Type II5/1.5/12 10/10/10 CA 1 1 100/100/120 Type II5/2.2/12 10/10/10 W6 1 1 100/100/120 Type II5/12/12 10/10/10 M6 1 1 50/120/120 Type II
5.2/12/12 15/8/8 BA 1 1 100/180/180 Type II5.2/12/12 5/16/7 AE 1 1 60/160/120 Type II5/12/24 10/10/5 U6 1 1 50/120/240 Type II5/15/15 10/8/8 V6 1 1 50/150/150 Type II5/24/24 10/5/5 R6 1 1 50/240/240 Type II12/12/12 10/10/10 N6 1 1 120/120/120 Type II5/15/12 10/8/10 EC 1 1 50/150/120 Type II24/12/12 5/10/10 P6 1 1 240/120/120 Type II
NOTES: A) For ambient temperatures above 50 °C, output current must be linearly derated to 50% at the maximum operational ambienttemperature, 70 °C.
B) The output noise and ripple measurement is bandwidth limited to 20 MHz.C) Module is designed to accommodate output cable losses of up to one volt.D) A4 module provides 220A in chassis with slot compatibility rating of 3, and 250A in chassis with slot compatibility rating of 4.E) Module is designed for use in applications demanding low noise and ripple. Consult factory for further specifications.F) Not to be used with SPM2 and SPM3 chassis.G) All triple output modules, as well as the M4 dual-output module, have floating outputs. Like voltages may be shared
within the same module. All triple output adjustments and interface signals are for output #1. Consult factory for moreinformation.
H) The dedicated negative (-) output is quasi-regulated. Both outputs require a small minimum load to perform to specification.Consult factory for more information.
SINGLE VOLTAGE OUTPUT MODULES (Continued)NOMINAL ADJUSTMENT CURRENT (AMPS) MODULE SLOTS SLOT NOISE & RIPPLE (mV PK-PK) OUTPUTVOLTAGE RANGE @ 50°C (NOTE A) USED COMPATIBILITY TYPICAL/MAX (NOTE B) CONNECTION
28V 25.2 - 30.8 29 E5 1 5 70/100 Type I 30V 27 - 33 8 EG 1 1 30/40 Type II36V 32.4 - 39.6 20 J8 1 4 100/200 Type I 36V 32.4 - 39.6 23 J5 1 5 100/200 Type I 48V 43.2 - 52.8 5 G1 1 1 400/480 Type II 48V 43.2 - 52.8 12.5 G4 (Note E) 1 3 40/60 Type I 48V 43.2 - 52.8 16 G8 1 4 60/100 Type I48V 43.2 - 52.8 19 G6 1 5 60/100 Type I
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Linear Power Supplies > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
54
• Worldwide AC Input Capabilities:100/120/220/230/240 VAC
• ±0.05% Output Regulation• Low Output Ripple• UL, CSA, and TÜV Approvals• Mean Time Before Failure (MTBF) in
Excess of 300,000 Hours• CE Marked to Low Voltage Directive• 100% Burn-In• 2-Year Warranty• Overvoltage Protection (OVP)
Standard on 5V Single Outputs;Optional for Outputs Under 48V
Nominal Max Model Input Case AdditionalVout* Amps 100 to 264 VAC Type Features & Notes
5Vout5 1.5 HAA5-1.5/OVP-A B A
5 3 HB5-3/OVP-A B A, C
5 6 HC5-6/OVP-A C A, C
5 9 HN5-9/OVP-A N A, C
5 12 HD5-12/OVP-A D A, C
5 18 HE5-18/OVP-A E A, C
5 25 F5-25/OVP-A F A, C, D, H
5 35 G5-35/OVP-A F A, C, D, H
5 50 CP197-A F A, C, D
12 to 15Vout12 0.9 HA15-0.9-A B12 1.7 HB12-1.7-A B C
12 3.4 HC12-3.4-A C C
12 5.1 HN12-5.1-A N C
12 6.8 HD12-6.8-A D C
12 10.2 HE12-10.2-A E C
12 16 F15-15-A F C, D, H
15* 0.9 HA15-0.9-A B
15 1.5 HB15-1.5-A B C
15 3 HC15-3-A C C
15 4.5 HN15-4.5-A N C
15 6 HD15-6-A D C
15 9 HE15-9-A E C
15* 15 F15-15-A F C, D, H
24 to 28Vout24 0.5 HA24-0.5-A B24 1.2 HB24-1.2-A B C
24 2.4 HC24-2.4-A C C
24 3.6 HN24-3.6-A N C
24 4.8 HD24-4.8-A D C
24 7.2 HE24-7.2-A E C
24 12 F24-12-A F C, D, H
28* 0.5 HA24-0.5-A B
28 1 HB28-1-A B C
28 2 HC28-2-A C C
28 3 HN28-3-A N C
28 4 HD28-4-A D C
28 6 HE28-6-A E C
28* 10 F24-12-A F C, D, H
48Vout48 0.5 HB48-0.5-A B48 1 HC48-1-A C
48 3 HD48-3-A D C
48 4 HE48-4-A E C
* May require jumpering or potentiometer adjustment.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Linear Power Supplies > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
55
Case DimensionsType (Inches)AA 6.50 x 4.00 x 2.10
B 4.87 x 4.00 x 2.10
BAA 10.25 x 4.00 x 2.95
BB 7.00 x 4.87 x 2.95
C 5.62 x 4.87 x 2.95
CBB 11.00 x 4.87 x 3.28
CC 9.38 x 4.87 x 3.28
CP131 11.00 x 4.87 x 3.28
D 9.00 x 4.87 x 3.28
DBB 14.25 x 4.87 x 3.38
DCC 15.00 x 4.88 x 4.55
E 14.00 x 4.87 x 3.53
F 16.75 x 4.88 x 5.00
N 7.00 x 4.87 x 3.28
Case DimensionsType (Millimeters)AA 165.10 x 101.60 x 53.34
B 123.70 x 101.60 x 53.34
BAA 260.35 x 101.60 x 74.93
BB 177.80 x 123.70 x 74.93
C 142.75 x 123.70 x 74.93
CBB 279.40 x 123.70 x 83.31
CC 238.25 x 123.70 x 83.31
CP131 279.40 x 123.70 x 83.31
D 228.60 x 123.70 x 83.31
DBB 361.95 x 123.70 x 85.85
DCC 381.00 x 123.95 x 115.57
E 355.60 x 123.70 x 89.66
F 425.50 x 123.95 x 127.00
N 177.80 x 123.70 x 83.31
A Overvoltage protection, set at 6.2 V ±0.4 V.B Non-adjustable 3-terminal regulator.C Remote sense provided.D With output inhibit and parallel
operation master/slave capability.E With output inhibit.F Adjustable 3-terminal regulator.G Can be made into an isolated output by
removing jumper W1.H Model requires 100 LFM forced-air
cooling above 75% of rated outputpower at 50 degrees C.
Nominal Max Model Input Case AdditionalVout* Amps 100 to 264 VAC Type Features & Notes
5V to 15Vout+5, –5 1.5, 1.5 HAA5-1.5/OVP-A AA A
+5, –5 3, 3 HBB5-3/OVP-A BB A
+5, –5 6, 6 HCC5-6/OVP-A CC A, C
+5, +12 2, 4 CP323-A N A, E
5, 12 to 15 2, 0.5 HAA512-A AA A
5, 12 to 15 3, 1.25 HBB512-A BB A, C
5, 12 to 15 6, 2.5 HCC512-A CC A, C
+12, –5* 1, 0.4 HAA15-0.8-A AA C
+12, –5* 1.7, 0.7 HBB15-1.5-A BB C
+12, –12 0.4, 0.4 HAD12-0.4-A B B
+12, –12 1, 1 HAA15-0.8-A AA C
+12, –12 1.7, 1.7 HBB15-1.5-A BB C
+12, –12 3.4, 3.4 HCC15-3-A CC C
+12, –12* 5, 5 HDD15-5-A E C
+12, –15* 1, 0.8 HAA15-0.8-A AA C
+12, –15* 1.7, 1.5 HBB15-1.5-A BB C
+12, –15* 3.4, 3 HCC15-3-A CC C
+12, –15* 5, 5 HDD15-5-A E C
+15, –5* 0.8, 0.4 HAA15-0.8-A AA C
+15, –5* 1.5, 0.7 HBB15-1.5-A BB C
+15, –12* 0.8, 1 HAA15-0.8-A AA C
+15, –12* 1.5, 1.7 HBB15-1.5-A BB C
+15, –12* 3, 3.4 HCC15-3-A CC C
15, –12* 5, 5 HDD15-5-A E C
15V to 24Vout+15, –15 0.4, 0.4 HAD15-0.4-A B B
+15, –15 0.8, 0.8 HAA15-0.8-A AA C
+15, –15* 1.5, 1.5 HBB15-1.5-A BB C
+15, –15* 3, 3 HCC15-3-A CC C
+15, –15 5, 5 HDD15-5-A E C
+24, –24 0.6, 0.6 HAA24-0.6-A AA
+24, –24 1.2, 1.2 HBB24-1.2-A BB
+24, –24 2.4, 2.4 HCC24-2.4-A CC C
* May require jumpering or potentiometer adjustment.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Linear Power Supplies > Triple Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
56
Case DimensionsType (Inches)AA 6.50 x 4.00 x 2.10
B 4.87 x 4.00 x 2.10
BAA 10.25 x 4.00 x 2.95
BB 7.00 x 4.87 x 2.95
C 5.62 x 4.87 x 2.95
CBB 11.00 x 4.87 x 3.28
CC 9.38 x 4.87 x 3.28
CP131 11.00 x 4.87 x 3.28
D 9.00 x 4.87 x 3.28
DBB 14.25 x 4.87 x 3.38
DCC 15.00 x 4.88 x 4.55
E 14.00 x 4.87 x 3.53
F 16.75 x 4.88 x 5.00
N 7.00 x 4.87 x 3.28
Case DimensionsType (Millimeters)AA 165.10 x 101.60 x 53.34
B 123.70 x 101.60 x 53.34
BAA 260.35 x 101.60 x 74.93
BB 177.80 x 123.70 x 74.93
C 142.75 x 123.70 x 74.93
CBB 279.40 x 123.70 x 83.31
CC 238.25 x 123.70 x 83.31
CP131 279.40 x 123.70 x 83.31
D 228.60 x 123.70 x 83.31
DBB 361.95 x 123.70 x 85.85
DCC 381.00 x 123.95 x 115.57
E 355.60 x 123.70 x 89.66
F 425.50 x 123.95 x 127.00
N 177.80 x 123.70 x 83.31
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.C Remote sense provided.D With output inhibit and parallel
operation master/slave capability.E With output inhibit.F Adjustable 3-terminal regulator.G Can be made into an isolated output
by removing jumper W1.H Model requires 100 LFM forced-air
cooling above 75% of rated outputpower at 50 degrees C.
Nominal Max Model Input Case AdditionalVout* Amps 100 to 264 VAC Type Features & Notes
5V to 15Vout+5, +12, –5* 2, 0.4, 0.4 HTAA-16W-A AA A
5, +12, –5* 3, 1, 0.4 HBAA-40W-A BAA A, C
+5, +12, –5* 6, 1, 0.4 HCAA-60W-A D A, C
5, +12, –5* 6, 1.7, 0.7 HCBB-75W-A CBB C
5, +12, –5* 8, 1.7, 0.7 CP131-A CP131 A, C
5, +12, –5* 12, 1.7, 0.7 HDBB-105W-A DBB A, C
5, +12, –12 2, 0.4, 0.4 HTAA-16W-A AA A
5, +12, –12 3, 1, 1 HBAA-40W-A BAA A, C
+5, +12, –12 6, 1, 1 HCAA-60W-A D A, C
5, +12, –12 6, 1.7, 1.7 HCBB-75W-A CBB C
5, +12, –12 8, 1.7, 1.7 CP131-A CP131 A, C
5, +12, –12 12, 1.7, 1.7 HDBB-105W-A DBB C
5, +12, –12 12, 3.4, 3.4 HDCC-150W-A DCC A, C
5, +12, –15* 2, 0.4, 0.4 HTAA-16W-A AA A
5, +12, –15* 3, 1, 0.8 HBAA-40W-A BAA A, C
+5, +12, –15* 6, 1, 1 HCAA-60W-A D A, C
5, +12, –15 6, 1.7, 1.5 HCBB-75W-A CBB C
5, +12, –15 8, 1.7, 1.5 CP131-A CP131 A, C
5, +12, –15* 12, 1.7, 1.5 HDBB-105W-A DBB C
5, +12, –15 12, 3.4, 3 HDCC-150W-A DCC A, C
5, +15, –5* 2, 0.4, 0.4 HTAA-16W-A AA A
5, +15, –5* 3, 0.8, 0.4 HBAA-40W-A BAA A, C
+5, +15, –5* 6, 1, 0.4 HCAA-60W-A D A, C
5, +15, –5* 6, 1.5, 0.7 HCBB-75W-A CBB C
5, +15, –5* 8, 1.5, 0.7 CP131-A CP131 A,
5, +15, –5* 12, 1.5, 0.7 HDBB-105W-A DBB C
5, +15, –12* 2, 0.4, 0.4 HTAA-16W-A AA A
5, +15, –12* 3, 0.8, 1 HBAA-40W-A BAA A, C
+5, +15, –12* 6, 1, 1 HCAA-60W-A D A, C
5, +15, –12 6, 1.5, 1.7 HCBB-75W-A CBB C
5, +15, –12 8, 1.5, 1.7 CP131-A CP131 A, C
5, +15, –12* 12, 1.5, 1.7 HDBB-105W-A DBB C
5, +15, –12 12, 3, 3.4 HDCC-150W-A DCC A, C
5, +15, –15* 2, 0.4, 0.4 HTAA-16W-A AA A
5, +15, –15* 3, 0.8, 0.8 HBAA-40W-A BAA A, C
+5, +15, –15* 6, 1, 1 HCAA-60W-A D A, C
5, +15, –15 6, 1.5, 1.5 HCBB-75W-A CBB C
5, +15, –15 8, 1.5, 1.5 CP131-A CP131 A, C
5, +15, –15* 12, 1.5, 1.5 HDBB-105W-A DBB C
5, +15, –15 12, 3, 3 HDCC-150W-A DCC A, C
* May require jumpering or potentiometer adjustment.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
CompactPCI > AC-DC & DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
57
Height Input +5V +3.3V +12V -12VModel Watts Profile Voltage Current Current Current Current
CPD200-4530 200 3U 36-75 VDC 40 A 40 A 5.5 A 2 A
CPD250-4530 250 3U 36-75 VDC 40 A 40 A 5.5 A 2 A
CPA200-4530 200 3U 90-264 VAC 40 A 40 A 5.5 A 2 A
CPA250-4530 250 3U 90-264 VAC 40 A 40 A 5.5 A 2 A
CPA500-4530 500 6U 90-264 VAC 50 A 60 A 12 A 4 ACPD200/CPD250
3U x 8HP (8TE) x 6.3" (160mm)
6U x 8HP (8TE) x 6.3" (160mm)
CPA200/CPA250
CPA500
3U x 8HP (8TE) x 6.3" (160mm)
• Fully Compliant to CompactPCI Per PICMGSpecifications
• High Density Design in an Industry StandardPackage
• High Efficiency Topology (>80%)• Remote Sense and Active Current Share for
3 Outputs
• Built-In ORing FETs for RedundantApplications
• AC-DC Models Have Active Power FactorCorrection
• Conformal Coating Option
Power-One’s hot-swap CompactPCI power supplies are fully compliant to the PICMG 2.11 Power Interface Specification,and use a standard Positronic 47-pin connector. EDGE technology delivers up to 40 amperes on both the +5 and +3.3 voltoutputs at 50 ºC on the 3U models, and 50 and 60 amperes respectively, on the 6U model’s +5 and +3.3 volt outputs.
Remote sense and active current share on the +5, +3.3, and +12 volt outputs, along with ORing FETs facilitate use inredundant, hot-swap applications. These feature-rich products meet international safety standards, and display the CE Markfor the Low Voltage Directive (LVD).
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Power Over Ethernet
Unsigned output voltages are isolated and can be used as either + or - polarities.
58
• Provides full compliance to IEEE 802.3AF• Extremely low noise and ripple• 48 VDC output has 2250 VDC isolation from the 12 VDC outputs and I2C interface• 85 to 264 VAC input range with IEC61000-3-2 compliant 98% efficient PFC• Full power operation to 50 °C with power-derated operation to 70 °C• Internal diode isolation for redundant operation of up to 30 PAL’s
• Standard ½-brick footprint and pinout• Fully regulated output • High efficiency• Input-to-output isolation: 2,250 VDC
The 10.4" x 4" x 1.6" package is designed for 1U high applications and features a front panel that includes alarm andmonitor LED's, AC input connector, on/off switch, integral handle, and a fan inlet. The hot-swap SSI type rear connectorprovides output power and access to I2C, power fail, active current share, remote sense, output good, power-supplypresent, and remote enable interface signals.
Protection features include overload and short circuit, brownout, overtemperature/fan fail warning and shutdown, outputovervoltage, and MOV input-transient. Agency approvals include UL1950, CSA 950, and EN60950 (TUV).
Factory Output Max VACSet Vout Trim Range Amps Input Watts Model
48 N/A 8 85 to 264 400 PALS400-248212 N/A 16
48 N/A 9 85 to 264 600 PALS600-248212 N/A 16
10.40 x 4.00 x 1.59 inch264.2 x 101.6 x 40.4 mm
PALS400/PALS600
Input Factory Output MaxVoltage Set Vout Trim Range Amps Model
36 to 75 52.5 50 to 53 3.8 HHS04Z52
36 to 75 53.7 51.2 to 54.2 4.8 HHS05Z55
Power Over Ethernet > DC-DC
HHS04 & HHS052.40 x 2.28 x 0.42 inch61.0 x 57.9 x 10.7 mm
Power Over Ethernet > AC-DC
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Railway & Rugged Solutions Overview
59
A Proven Track Record
Isolated Cassette Style AC-DC and DC-DCA broad range of extremely flexible cassettes are available,providing from one to four outputs. • Features include high efficiencies, low noise outputs,
power factor correction, excellent line/load response,wide-range inputs, and extensive interface capabilities.
• Chassis, rack, and DIN-Rail mounting• Rack power solutions can be configured from readily
available front panels and rack frames.
These non-isolated buck-converter topology convertersfeature no power derating over the entire operatingtemperature range, no minimum load operation, wideoutput adjustment ranges, and -40 to 71 °C extended-temperature-range options.
DC-DC Positive Switching Regulators
DIN-Rail Mount, Including EN 50155 Compliant ModelsSingle and dual output converters and battery chargers areideal power sources for demanding applications such asbuilding control systems, factory automation, industrialcontrols, instrumentation, electromagnetic drives, fans,and other DC loads.
Extremely robust electrical and mechanical designs have enabled Power-One’s broad rangeof railway and rugged products to establish a proven track record of industry-leadingreliability, in a diverse array of transportation, communications, and industrial infrastructureapplications.
Rolling Stock Custom Power Capabilities
Power-One has field-proven design andmanufacturing capabilities for a widerange of rolling-stock power applications.Custom-product capabilities range fromlow-wattage solutions, such as powersystems for onboard lighting and watercirculation, to train-wide 55 kW auxiliarypower converters.
Please contact your local Power-Onerepresentative to discuss your railwaypower-conversion requirements.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
DIN-Rail Mount
Unsigned output voltages are isolated and can be used as either + or - polarities.
60
LOK, LOR, LOS 4000Series
4.49 x 3.54 x 1.5 inch114 x 90 x 38 mm
W Series with PFC
5.43 x 4.49 x 4.05 inch138 x 114 x 103 mm
VACVout Amps Input Watts Model Options
5.1 5.2 85 to 264 26 LOK4001-2RLD F, K
12 1.25 85 to 264 15 LOS4301-2 F, K
12 2.5 85 to 264 30 LOR4301-2 F, K
12 4 85 to 264 48 LOK4301-2R F, K
24 0.65 85 to 264 15 LOS4601-2 F, K
24 1.25 85 to 264 30 LOR4601-2 F, K
24 2 85 to 264 48 LOK4601-2R F, K
48 1 85 to 264 48 LOK4801-2R F, K
• DC input 90 to 250 VDC• LOS/LOR models are
UL 508 listed• Class I equipment• Short circuit protection• Adjustable output for models
with R suffix• Battery charger models with
temperature sensor available
All ratings at 50 °COptions/Features:F Second fuse in the neutral lineK Screw terminal connectors
Vout Amps VAC Max1, 2 1,2 Input Watts Model Options
Output Voltage Adjusts 60-110% By Specifying “R” Option
24.7 5 85 to 264 125 LWR1601-6E F, K2, D1, D2, D5, M1, M2, R
24.7 10 85 to 264 250 LWN1601-6E F, K2, D1, D2, D5, M1, M2, R
37 3.3 85 to 264 125 LWR1701-6E F, K2, D1, D2, D5, M1, M2, R
37 6.6 85 to 264 250 LWN1701-6E F, K2, D1, D2, D5, M1, M2, R
49.4 2.5 85 to 264 125 LWR1801-6E F, K2, D1, D2, D5, M1, M2, R
49.4 5 85 to 264 250 LWN1801-6E F, K2, D1, D2, D5, M1, M2, R
24.7, 24.7 5, 5 85 to 264 250 LWN2660-6E F, K2, D1, D2, D5, M1, M2, R
37, 37 3.3, 3.3 85 to 264 250 LWN2770-6E F, K2, D1, D2, D5, M1, M2, R
49.4, 49.4 2.5, 2.5 85 to 264 250 LWN2880-6E F, K2, D1, D2, D5, M1, M2, R
All ratings at 60 °COptions:
R Vout adjustD2 Input voltage monitoring
D1, D5 Output voltage monitors
• DC input 90 to 350 VDC• Compact 35 mm DIN-rail snap-
fit design or wall mounting• Ambient temperature range
-6: –40 to +60 °C• Battery charger models with
temperature sensor available
W Series (125 to 250 Watts)
F Second built-in fuse K2 Connector with screw terminals
M1, M2 Optionboard: Includes different options
LOK, LOR, LOS Series (15 to 48 Watts)
Vout VACVout Trim Range Amps Input Watts Model
24 21.6 to 26.4 1.25 85 to 264 30 LPDS30-24
24 21.6 to 26.4 2.5 85 to 264 60 LPDS60-24
LPDS Series (30 to 60 Watts)
• Isolation Class II• EMC Emissions Compliance - Class B conducted and
radiated• Convection cooled, -20 to +60 °C; no derating or
airflow required• DC voltage adjust via potentiometer
• UL508 Compliant (Industrial control equipment)• High Efficiency up to 87%• Current share with redundancy• 3-Year Warranty• Dimensions: 3.54 x 3.15 x1.77 inch
90 x 80 x 45 mm
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
DIN-Rail Mount
Unsigned output voltages are isolated and can be used as either + or - polarities.
61
Alpha-sorted graphics anddimensions augment modellistings from both pages.
Vout Amps1, 2 1, 2 VAC Input Watts Model Options
Output Voltage Adjusts 60-110% By Specifying “R” Option
24.7 15 85 to 264 375 LXR1601-6 F, K2, D1, D2, D5, M2, R
24.7 20 85 to 264 500 LXN1601-6 F, K2, D1, D2, D5, M2, R
37 9.9 85 to 264 375 LXR1701-6 F, K2, D1, D2, D5, M2, R
37 13.2 85 to 264 500 LXN1701-6 F, K2, D1, D2, D5, M2, R
49.4 7.5 85 to 264 375 LXR1801-6 F, K2, D1, D2, D5, M2, R
49.4 10 85 to 264 500 LXN1801-6 F, K2, D1, D2, D5, M2, R
24.7, 24.7 10, 10 85 to 264 500 LXN2660-6 F, K2, D1, D2, D5, M2, R
49.4, 49.4 5, 5 85 to 264 500 LXN2880-6 F, K2, D1, D2, D5, M2, R
• DC input 90 to 350 VDC• Safety: Class I equipment according to
IEC/EN60950, UL 60950, EN 61010-1• Compact 35 mm DIN-rail snap-fit design or
wall mounting• Ambient temperature range -6: –40 to 60 °C• Battery charger models with temperature
sensor available
Options:R Vout adjustD2 Input voltage monitoringD1, D5 Output voltage monitors
Battery deep discharged V bat lowF Second built-in fuse K2 Connector with screw terminalsM2 Optionboard: Includes R, D2, D5
X Series with PFC
7.64 x 5.43 x 4.47 inch194 x 138 x 114 mm
DIN-Rail Mount > Battery Chargers
Battery Nominal Nominal OutputModel Voltage Watts Output Voltage Amps
LOK4140-2RLD 12 49 12.8 3.6
LOK4240-2RLD 24 49 25.7 1.8
LWR1240-6EM1 24 115 27.3 4.2
LWN1240-6EM1 24 230 27.3 8.45
LXR1240-6M1 24 345 27.3 12.6
LXN1240-6M1 24 460 27.3 16.9
LOK4740-2RLD 48 49 51.4 0.9
LWR1740-6EM1 48 115 54.5 2.1
LWN1740-6EM1 48 230 54.5 4.2
LXR1740-6M1 48 345 54.5 6.3
LXN1740-6M1 48 460 54.5 8.4
Please refer to data sheets for availability of EMI options, temperature sensoroptions, and safety agency certifications.
Other battery chargers are available in Cassette packages; refer to the AC-DCCassette Section. Contact factory for availability.
Vout Amps VDC Max1, 2 1,2 Input Watts Model Options
24.7 5 66 to 150 120 EWR1601-0 R, M1, M2, Q, K2
24.7, 24.7 5, 5 66 to 150 240 EWN2660-0 R, M1, M2, Q, K2
W Series > EN 50155 Compliant
A summary of an article describing an EN 50155 railway power-supply application,utilizing the W-Series, is located on page 80.
X Series (375 to 500 Watts)
All ratings at 70 °C
W Series for RailwayApplications
• DC input 66 to 150 VDC• Safety according to IEC/EN
60950, EN 50155 compliant• Ambient temp. range
–40 to +71 °C
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
PSA, PSR2.76 x 2.00 x 1.00 inch70.1 x 50.8 x 25.4 mm
PSB4.17 x 2.72 x 1.27 inch
106 x 69 x 32.2 mm
Options:-9 Ambient temperature range
–40 to 71°CA Test socketsB Cooling plate largeB1 Cooling plate smallC Thyristor-Crowbar D “Save Data” undervoltage
monitorE Inrush current limitationi InhibitL Input filterP Potentiometer for VoutR External output voltage
controlY Small soldering pins
(0.5 x 1 mm)
Vout Amps VDC Input Watts Efficiency Model Options+3.3 12 6 to 40 39.6 77 PSC3E12-2 iR-Package
+5 2 8 to 80 10 74 PSR52-7 Y
+5 3 8 to 80 15 79 PSR53-7 -9, i, P, R, Y
+5 4 7 to 40 20 83 PSR54-7 -9, i, P, R, Y
+5 5 7 to 35 25 83 PSA55-7 -9, i, P, R, Y
+5.1 2 8 to 40 10.2 75 PSA5A2-2 iRY-Package
+5.1 5 15 to 144 25.5 80 PSB5A4-7iR -9, L, P, C
+5.1 5 7 to 35 25.5 83 PSA5A5-2 iRY-Package
+5.1 6 8 to 80 30.6 81 PSB5A6-7iR -9, L, P, C
+5.1 7 7 to 40 35.7 84 PSB5A7-7iR -9, L, P, C
+5.1 8 7 to 40 40.8 81 PSB5A8-2 iR-Package
+5.1 10 8 to 80 51 79 PSC5A10-7iR -9, L, P, C, D
+5.1 11 8 to 40 56.1 79 PSC5A11-2 iR-Package
+5.1 12 7 to 40 61.2 83 PSC5A12-7iR -9, L, P, C, D
+12 1.5 18 to 144 18 87 PSA121.5-7iR -9, P, Y
+12 2.5 15 to 80 30 87 PSR122.5-7 -9, i, P, R, Y
+12 3 15 to 40 36 89 PSA123-2 iRY-Package
+12 4 18 to 144 48 89 PSB123-7iR -9, L, P, C
+12 5 15 to 80 60 90 PSB125-7iR -9, L, P, C
+12 6 15 to 40 72 90 PSB126-2 iR-Package
+12 6 18 to 144 72 89 PSC126-7iR -9, L, P, C, D
+12 8 15 to 80 96 90 PSC128-7iR -9, L, P, C, D
+12 9 15 to 40 108 90 PSC129-2 iR-Package
+15 1.5 22 to 144 22.5 89 PSA151.5-7iR -9, P, Y
+15 2.5 19 to 80 37.5 89 PSR152.5-7 -9, i, P, R, Y
+15 3 19 to 40 45 90 PSA153-2 iRY-Package
+15 4 22 to 144 60 90 PSB153-7iR -9, L, P, C
+15 5 19 to 80 75 92 PSB155-7iR -9, L, P, C
+15 6 19 to 40 90 92 PSB156-2 iR-Package
+15 6 22 to 144 90 90 PSC156-7iR -9, L, P, C, D
+15 8 19 to 80 120 91 PSC158-7iR -9, L, P, C, D
+15 9 19 to 40 135 91 PSC159-2 iR-Package
+24 1.5 31 to 144 36 93 PSA241.5-7iR -9, P, Y
+24 2 29 to 80 48 92 PSR242-7 -9, i, P, R, Y
+24 2.5 29 to 60 60 93 PSA242.5-2 iRY-Package
+24 4 31 to 144 96 94 PSB243-7iR -9, L, P, C
+24 5 29 to 80 120 95 PSB245-7iR -9, L, P, C
+24 6 29 to 60 144 95 PSB246-2 iR-Package
+24 6 31 to 144 144 94 PSC246-7iR -9, L, P, C, D
+24 8 29 to 80 192 94 PSC248-7iR -9, L, P, C, D
+24 9 29 to 60 216 94 PSC249-2 iR-Package
+36 1.2 44 to 144 43.2 95 PSA361-7iR -9, P, Y
+36 2 42 to 80 72 94 PSR362-7 -9, i, P, R, Y
+36 4 44 to 144 144 95 PSB363-7iR -9, L, P, C
+36 5 42 to 80 180 96 PSB365-7iR -9, L, P, C
+36 6 44 to 144 216 95 PSC366-7iR -9, L, P, C, D
+36 8 42 to 80 288 96 PSC368-7iR -9, L, P, C, D
+48 1 58 to 144 48 95 PSA481-7iR -9, P, Y
+48 4 58 to 144 192 96 PSB483-7iR -9, L, P, Cwww.power-one.com
Non-Isolated Positive Switching Regulators
62
PSC5.94 x 3.46 x 1.27 inch
151 x 88 x 32.2 mm
PSR > Chassis Mount
Output Voltage Adjusts 0-110% in PSS Models with “R” Suffix;Ouput Voltage Adjusts 0-108% in All Other Models with “R” Suffix.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Non-Isolated Positive Switching Regulators
63
Alpha-sorted graphics anddimensions augment modellistings from both pages.
PSK6.77 x 4.37 x 3.15 inch
171.9 x 111 (3U) x 80 (16TE) mm
PSL6.83 x 4.21 x 1.44 inch173.7 x 107 x 36.5 mm
PSS6.77 x 4.37 x 2.36 inch
171.9 x 111 (3U) x 60 (12TE) mm
Options:-9 Ambient temperature range
–40 to 71 °CA Test socketsB Cooling plate largeB1 Cooling plate smallC Thyristor-Crowbar D “Save Data” undervoltage
monitorE Inrush current limitationi InhibitL Input filterP Potentiometer for Vout adjustR External output voltage control
Vout Amps VDC Input Watts Efficiency Model Options+5.1 10 8 to 80 51 79 PSL5A10-7R -9, L, i, P, C, D, A
+5.1 11 8 to 40 56.1 79 PSL5A11-2R
+5.1 12 7 to 40 61.2 83 PSL5A12-7R -9, L, i, P, C, D, A
+5.1 12 8 to 80 61.2 79 PSS5A12-7 -9, E, P, C, B, B1
+5.1 14 8 to 40 71.4 83 PSS5A14-2 B, B1
+5.1 16 8 to 80 81.6 79 PSK5A16-7 -9, E, P, C, B, B1
+5.1 18 8 to 40 91.8 82 PSK5A18-2 B, B1
+5.1 20 8 to 80 102 79 PSK5A20-7 -9, E, P, C, B, B1
+5.1 25 8 to 40 127.5 82 PSK5A25-7 -9, E, P, C, B, B1
+12 6 18 to 144 72 89 PSL126-7R -9, L, i, P, C, D, A
+12 8 15 to 80 96 90 PSL128-7R -9, L, i, P, C, D, A
+12 9 15 to 40 108 90 PSL129-2R
+12 9 18 to 144 108 91 PSS129-7 -9, E, P, C, B, B1
+12 12 15 to 80 144 91 PSS1212-7 -9, E, P, C, B, B1
+12 12 18 to 144 144 91 PSK1212-7 -9, E, P, C, B, B1
+12 14 16 to 40 168 90 PSS1214-2 B, B1
+12 16 15 to 80 192 90 PSK1216-7 -9, E, P, C, B, B1
+12 18 16 to 40 216 90 PSK1218-2 B, B1
+12 20 15 to 80 240 90 PSK1220-7 -9, E, P, C, B, B1
+15 6 22 to 144 90 90 PSL156-7R -9, L, i, P, C, D, A
+15 8 19 to 80 120 91 PSL158-7R -9, L, i, P, C, D, A
+15 9 19 to 40 135 91 PSL159-2R
+24 6 31 to 144 144 94 PSL246-7R -9, L, i, P, C, D, A
+24 8 29 to 80 192 94 PSL248-7R -9, L, i, P, C, D, A
+24 9 29 to 60 216 94 PSL249-2R
+24 9 31 to 144 216 94 PSS249-7 -9, E, P, C, B, B1
+24 12 29 to 80 288 94 PSS2412-7 -9, E, P, C, B, B1
+24 12 31 to 144 288 94 PSK2412-7 -9, E, P, C, B, B1
+24 14 29 to 60 336 94 PSS2414-2 B, B1
+24 16 29 to 80 384 94 PSK2416-7 -9, E, P, C, B, B1
+24 18 29 to 60 432 94 PSK2418-2 B, B1
+24 20 29 to 80 480 94 PSK2420-7 -9, E, P, C, B, B1
+36 6 44 to 144 216 96 PSL366-7R -9, L, i, P, C, D, A
+36 8 42 to 80 288 96 PSL368-7R -9, L, i, P, C, D, A
+36 9 44 to 144 324 96 PSS369-7 -9, E, P, C, B, B1
+36 12 42 to 80 432 96 PSS3612-7 -9, E, P, C, B, B1
+36 12 44 to 144 432 96 PSK3612-7 -9, E, P, C, B, B1
+36 16 42 to 80 576 95 PSK3616-7 -9, E, P, C, B, B1
+36 20 42 to 80 720 95 PSK3620-7 -9, E, P, C, B, B1
+48 6 58 to 144 288 97 PSL486-7R -9, L, i, P, C, D, A
+48 9 58 to 144 432 97 PSS489-7 -9, E, P, C, B, B1
+48 12 58 to 144 576 97 PSK4812-7 -9, E, P, C, B, B1
PSR > Cassette Style
Output Voltage Adjusts 0-110% in PSS Models with “R” Suffix;Ouput Voltage Adjusts 0-108% in All Other Models with “R” Suffix.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Cassette > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
64
Vout Amps Model Input Model Input Model Input1, 2, 3 1, 2, 3 8 to 35 VDC 14 to 70 VDC 20 to 100 VDC Options
5.1 8 AM1001-7R BM1001-7R FM1001-7R -9, A, P, D
12 4 AM1301-7R BM1301-7R FM1301-7R -9, A, P, D
15 3.4 AM1501-7R BM1501-7R FM1501-7R -9, A, P, D
24 2 AM1601-7R BM1601-7R FM1601-7R -9, A, P, D
48 1 AM1901-7R BM1901-7R FM1901-7R -9, A, P, D
12, 12 2, 2 AM2320-7 BM2320-7 FM2320-7 -9, A, P, D
15, 15 1.7, 1.7 AM2540-7 BM2540-7 FM2540-7 -9, A, P, D
5.1, 12, 12 5, 0.7, 0.7 AM3020-7 BM3020-7 FM3020-7 -9, A, P, D
5.1, 15, 15 5, 0.6, 0.6 AM3040-7 BM3040-7 FM3040-7 -9, A, P, D
Vout Amps Model Input Model Input Model Input1, 2, 3 1, 2, 3 28 to 140 VDC 44 to 220 VDC 88 to 372 VDC Options
5.1 8 CM1001-7R DM1001-7R LM1001-7R -9, A, E, P, D
12 4 CM1301-7R DM1301-7R LM1301-7R -9, A, E, P, D
15 3.4 CM1501-7R DM1501-7R LM1501-7R -9, A, E, P, D
24 2 CM1601-7R DM1601-7R LM1601-7R -9, A, E, P, D
48 1 CM1901-7R DM1901-7R LM1901-7R -9, A, E, P, D
12, 12 2, 2 CM2320-7 DM2320-7 LM2320-7 -9, A, E, P, D
15, 15 1.7, 1.7 CM2540-7 DM2540-7 LM2540-7 -9, A, E, P, D
5.1, 12, 12 5, 0.7, 0.7 CM3020-7 DM3020-7 LM3020-7 -9, A, E, P, D
5.1, 15, 15 5, 0.6, 0.6 CM3040-7 DM3040-7 LM3040-7 -9, A, E, P, D
M Series (40 to 50 Watts)
M Series
6.6 x 4.4(3U) x 1.54(8 TE) inch168 x 111 x 39 mm
Output Adjustment RangesThe following adjustment rangesapply to all single-output models.
Vout Low High
5.1 0 5.612 0 13.215 0 16.524 0 26.448 0 52.8
• Safety: Class I equipment according toIEC/EN 60950, UL 60950.
• Extremely wide input voltage range• Input over- and undervoltage lockout• Output voltage control (R) and inhibit• Surge and transient suppression circuitry• Fully isolated outputs• Outputs open- and short-circuit proof• Ambient temperature range
-7: –25 to 71 °C• No derating over temperature
Options:-9 Ambient temperature range –40 to 71 °CE Inrush current limitation (CM, LM, and LM models only)D Save data signalP Potentiometer for Vout adjustA Output voltage test socketsV AC fail signal according to VME Standard (only models
with Vo = 5.1)
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Cassette > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
65
Vout Amps Model Input Model Input Model Input1, 2 1, 2 8 to 35 VDC 14 to 70 VDC 20 to 100 VDC Options
5.1 16 AS1001-7R BS1001-7R FS1001-7R -9, D, V, P, T, B1, B2
12 8 AS1301-7R BS1301-7R FS1301-7R -9, D, P, T, B1, B2
15 6.5 AS1501-7R BS1501-7R FS1501-7R -9, D, P, T, B1, B2
24 4.2 AS1601-7R BS1601-7R FS1601-7R -9, D, P, T, B1, B2
12, 12 4, 4 AS2320-7R BS2320-7R FS2320-7R -9, D, P, T, B1, B2
15, 15 3.2, 3.2 AS2540-7R BS2540-7R FS2540-7R -9, D, P, T, B1, B2
24, 24 2, 2 AS2660-7R BS2660-7R FS2660-7R -9, D, P, T, B1, B2
Vout Amps Model Input Model Input Model Input1, 2 1, 2 28 to 140 VDC 44 to 220 VDC 67 to 385 VDC Options
5.1 16 CS1001-7R DS1001-7R ES1001-7R -9, E, D, V, P, T, B1, B2
12 8 CS1301-7R DS1301-7R ES1301-7R -9, E, D, P, T, B1, B2
15 6.5 CS1501-7R DS1501-7R ES1501-7R -9, E, D, P, T, B1, B2
24 4.2 CS1601-7R DS1601-7R ES1601-7R -9, E, D, P, T, B1, B2
12, 12 4, 4 CS2320-7R DS2320-7R ES2320-7R -9, E, D, P, T, B1, B2
15, 15 3.2, 3.2 CS2540-7R DS2540-7R ES2540-7R -9, E, D, P, T, B1, B2
24, 24 2, 2 CS2660-7R DS2660-7R ES2660-7R -9, E, D, P, T, B1, B2
S Series (80 to 96 Watts)
S Series
6.6 x 4.4(3U) x 2.4(12 TE) inch168 x 111 x 60 mm
Please see the AC-DCS-Series data sheets for AC inputLS models.
Output Adjustment RangesThe following adjustment rangesapply to all models.
Vout Low High
5.1 0 5.612 0 13.215 0 16.524 0 26.448 0 52.8
• Safety: Class I equipment according toIEC/EN 60950, UL 60950; BS, CS, DS, ES, FScomply with EN 50155
• Extremely wide input voltage range• Input over- and undervoltage lockout• Output voltage control (R) and inhibit• Surge and transient suppression circuitry• Fully isolated outputs• Outputs open- and short-circuit proof• Ambient temperature range
-7: –25 to 71 °C• No derating over temperature
Options:-9 Ambient temperature range –40 to 71 °CE Inrush current limitation (CS, DS, ES, FS, and LS
models only)1
D Save data signalP Potentiometer for Vout adjustT Current sharing (K and S Series only)
B1,B2 Cooling plate (K and S Series only)A Output voltage test sockets (M Series only)V AC fail signal according to VME Standard (only
models with Vo = 5.1)
1 Option E is mandatory for S Series models with the-9 option.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Cassette > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
66
• Safety: Class I equipment according to IEC/EN 60950, UL 60950, compliant to EN 50155;48Q Series compliant to ETS 300 132-2
• Extremely slim case (4TE wide), fully enclosed• Outputs, units parallel or series configurable• Flexible load distribution• Very high efficiency up to 90%• Ambient temperature ranges:
-7: –25 to 71 °C-2: –10 to 50 °C
• Output voltage control (R) and inhibit• Output OK monitor• Redundant operation and current sharing• Extremely low inrush current, hot plug-in
Options:-9 Ambient temperature range
–40 to 71 °CB1, B3 Cooling plateP Potentiometer for Vout adjust
Vout Amps Amps Model Input Model Input Model Input1, 2 1, 2 TA = 50°C 14.4 to 36 VDC 21.6 to 54 VDC 33.6 to 75 VDC Options
3.3 20 25 BQ1101-7 GQ1101-7 CQ1101-7 -9, B1, B3
5.1 16 20 BQ1001-7R GQ1001-7R CQ1001-7R -9, B1, B3, P
5.1, 5.1 7.5, 7.5 9.5, 9.5 BQ2001-7R GQ2001-7R CQ2001-7R -9, B1, B3
12, 12 4, 4 5, 5 BQ2320-7R GQ2320-7R CQ2320-7R -9, B1, B3, P
15, 15 3.3, 3.3 4, 4 BQ2540-7R GQ2540-7R CQ2540-7R -9, B1, B3, P
24, 24 2.2, 2.2 2.75, 2.75 BQ2660-7R GQ2660-7R CQ2660-7R -9, B1, B3, P
Vout Amps Amps Model Input Model Input Model Input1, 2 1, 2 TA = 50°C 43 to 108 VDC 65 to 150 VDC 38.4 to 75 VDC Options
3.3 20 25 DQ1101-7 EQ1101-7 -9, B1, B3
5.1 16 20 DQ1001-7R EQ1001-7R 48Q1001-2R -9, B1, B3, P
5.1, 5.1 7.5, 7.5 9.5, 9.5 DQ2001-7R EQ2001-7R -9, B1, B3
12, 12 4, 4 5, 5 DQ2320-7R EQ2320-7R 48Q2320-2R -9, B1, B3, P
15, 15 3.3, 3.3 4, 4 DQ2540-7R EQ2540-7R 48Q2540-2R -9, B1, B3, P
24, 24 2.2, 2.2 2.75, 2.75 DQ2660-7R EQ2660-7R 48Q2660-2R -9, B1, B3, P
Q Series (66 to 132 Watts)
Q Series
6.5 x 4.4(3U) x 0.8(4 TE) inch164 x 111 x 20 mm
Output Adjustment RangesThe following adjustment rangesapply to V1 and V2 outputs.
Vout Low High
3.3 3.3 3.3
5.1 4.1 5.612 7.2 13.215 9.0 16.524 14.4 26.448 28.8 52.8
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Cassette > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
67
Vout Amps VDC1, 2 1, 2 Model Input Options
5.1 20 AK1001-7R 8 to 35 -9, D, V, P, T, B1, B2
12 10 AK1301-7R 8 to 35 -9, D, P, T, B1, B2
15 8 AK1501-7R 8 to 35 -9, D, P, T, B1, B2
24 5 AK1601-7R 8 to 35 -9, D, P, T, B1, B2
12, 12 5, 5 AK2320-7R 8 to 35 -9, D, P, T, B1, B2
15, 15 4, 4 AK2540-7R 8 to 35 -9, D, P, T, B1, B2
24, 24 2.5, 2.5 AK2660-7R 8 to 35 -9, D, P, T, B1, B2
Vout Amps Model Input Model Input1, 2 1, 2 14 to 70 VDC 20 to 100 VDC Options
5.1 25 BK1001-7R FK1001-7R -9, D, V, P, T, B1, B2
12 12 BK1301-7R FK1301-7R -9, D, P, T, B1, B2
15 10 BK1501-7R FK1501-7R -9, D, P, T, B1, B2
24 6 BK1601-7R FK1601-7R -9, D, P, T, B1, B2
12, 12 6, 6 BK2320-7R FK2320-7R -9, D, P, T, B1, B2
15, 15 5, 5 BK2540-7R FK2540-7R -9, D, P, T, B1, B2
24, 24 3, 3 BK2660-7R FK2660-7R -9, D, P, T, B1, B2
Vout Amps Model Input Model Input Model Input Model Input1, 2 1, 2 28 to 140 VDC 44 to 220 VDC 67 to 385 VDC 88 to 372 VDC Options
5.1 25 CK1001-7R DK1001-7R LK1001-7R -9, E, D, V, P, T, B1, B2
12 12 CK1301-7R DK1301-7R EK1301-7R LK1301-7R -9, E, D, P, T, B1, B2
15 10 CK1501-7R DK1501-7R EK1501-7R LK1501-7R -9, E, D, P, T, B1, B2
24 6 CK1601-7R DK1601-7R EK1601-7R LK1601-7R -9, E, D, P, T, B1, B2
12, 12 6, 6 CK2320-7R DK2320-7R EK2320-7R LK2320-7R -9, E, D, P, T, B1, B2
15, 15 5, 5 CK2540-7R DK2540-7R EK2540-7R LK2540-7R -9, E, D, P, T, B1, B2
24, 24 3, 3 CK2660-7R DK2660-7R EK2660-7R LK2660-7R -9, E, D, P, T, B1, B2
• Safety: Class I equipment according toIEC/EN 60950, UL 60950; BK, CK, DK, EK, FKcomply with EN 50155.
• Extremely wide input voltage range• Input over- and undervoltage lockout• Output voltage control (R) and inhibit• Surge and transient suppression circuitry• Fully isolated outputs• Outputs open- and short-circuit proof• Ambient temperature range
-7: –25 to 71 °C• No derating over temperature
Options:-9 Ambient temperature range –40 to 71 °CE Inrush current limitation (CK, DK, EK, and LK
models only)1
D Save data signalP Potentiometer for Vout adjustT Current sharing
B1,B2 Cooling plateV AC fail signal according to VME Standard (only models
with Vo = 5.1)
1 Option E is mandatory for K Series models with the-9 option.
K Series (102 to 150 Watts)
K Series
6.6 x 4.4(3U) x 3.2(16 TE) inch168 x 111 x 80 mm
Please see the AC-DC K-Series data sheets for AC inputLK models.
Output Adjustment RangesThe following adjustment rangesapply to all models.
Vout Low High
5.1 0 5.612 0 13.215 0 16.524 0 26.4
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Cassette > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
68
Vout Vout Max. Nom. Model Input Model Input1, 4 2, 3 Watts Watts 16 to 36 VDC 33.6 to 75 VDC Options
3.3 132 100 BP1101-7R CP1101-7R -9, D, T, B1, B3
5.1 183 122 BP1001-7R CP1001-7R -9, D, T, B1, B3
12 192 120 BP1301-7R CP1301-7R -9, D, B1, B3
15 194 120 BP1501-7R CP1501-7R -9, D, B1, B3
24 192 120 BP1601-7R CP1601-7R -9, D, B1, B3
3.3 5.1 157 111 BP2101-7R CP2101-7R -9, D, T, B1, B3
5.1 5.1 182 122 BP2001-7R CP2001-7R -9, D, T, B1, B3
12 12 192 120 BP2320-7R CP2320-7R -9, D, B1, B3
15 15 194 120 BP2540-7R CP2540-7R -9, D, B1, B3
24 24 192 120 BP2660-7R CP2660-7R -9, D, B1, B3
5.1 12, 12 187 121 BP3020-7R CP3020-7R -9, D, T, B1, B3
5.1 15, 15 187 121 BP3040-7R CP3040-7R -9, D, T, B1, B3
5.1 24, 24 187 121 BP3060-7R CP3060-7R -9, D, T, B1, B3
5.1, 3.3 12, 12 146 90 BP4720-7R CP4720-7R -9, D, T, B1, B3
12, 12 12, 12 192 120 BP4320-7R CP4320-7R -9, D, B1, B3
15, 15 15, 15 192 120 BP4540-7R CP4540-7R -9, D, B1, B3
24, 24 24, 24 192 120 BP4660-7R CP4660-7R -9, D, B1, B3
Vout Vout Max. Nom. Model Input Model Input1, 4 2, 3 Watts Watts 40 to 101 VDC 66 to 150 VDC Options
3.3 132 100 DP1101-7R EP1101-7R -9, D, T, B1, B3
5.1 183 122 DP1001-7R EP1001-7R -9, D, T, B1, B3
12 192 120 DP1301-7R EP1301-7R -9, D, B1, B3
15 194 120 DP1501-7R EP1501-7R -9, D, B1, B3
24 192 120 DP1601-7R EP1601-7R -9, D, B1, B3
3.3 5.1 157 111 DP2101-7R EP2101-7R -9, D, T, B1, B3
5.1 5.1 182 122 DP2001-7R EP2001-7R -9, D, T, B1, B3
12 12 192 120 DP2320-7R EP2320-7R -9, D, B1, B3
15 15 194 120 DP2540-7R EP2540-7R -9, D, B1, B3
24 24 192 120 DP2660-7R EP2660-7R -9, D, B1, B3
5.1 12, 12 187 121 DP3020-7R EP3020-7R -9, D, T, B1, B3
5.1 15, 15 187 121 DP3040-7R EP3040-7R -9, D, T, B1, B3
5.1 24, 24 187 121 DP3060-7R EP3060-7R -9, D, T, B1, B3
5.1, 3.3 12, 12 146 90 DP4720-7R EP4720-7R -9, D, T, B1, B3
12, 12 12, 12 192 120 DP4320-7R EP4320-7R -9, D, B1, B3
15, 15 15, 15 192 120 DP4540-7R EP4540-7R -9, D, B1, B3
24, 24 24, 24 192 120 DP4660-7R EP4660-7R -9, D, B1, B3
P Series (90 to 194 Watts)
P Series
6.5 x 4.4(3U) x 0.8(4 TE) inch164 x 111 x 20 mm
Output Adjustment RangesThe following adjustment rangesapply to single-output modelsand V1 of multi-output models.
Vout Low High
3.3 1.8 3.65.1 2.75 5.612 6.5 13.215 8.1 16.524 13.0 26.4
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Cassette > DC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
69
Vout Vout Max. Nom. Model Input1, 4 2, 3 Watts Watts 21.6 to 50.4 VDC Options
3.3 132 100 GP1101-7R -9, D, T, B1, B3
5.1 183 122 GP1001-7R -9, D, T, B1, B3
12 192 120 GP1301-7R -9, D, B1, B3
15 194 120 GP1501-7R -9, D, B1, B3
24 192 120 GP1601-7R -9, D, B1, B3
3.3 5.1 157 111 GP2101-7R -9, D, T, B1, B3
5.1 5.1 182 122 GP2001-7R -9, D, T, B1, B3
12 12 192 120 GP2320-7R -9, D, B1, B3
15 15 194 120 GP2540-7R -9, D, B1, B3
24 24 192 120 GP2660-7R -9, D, B1, B3
5.1 12, 12 187 121 GP3020-7R -9, D, T, B1, B3
5.1 15, 15 187 121 GP3040-7R -9, D, T, B1, B3
5.1 24, 24 187 121 GP3060-7R -9, D, T, B1, B3
5.1, 3.3 12, 12 146 90 GP4720-7R -9, D, T, B1, B3
12, 12 12, 12 192 120 GP4320-7R -9, D, B1, B3
15, 15 15, 15 192 120 GP4540-7R -9, D, B1, B3
24, 24 24, 24 192 120 GP4660-7R -9, D, B1, B3
P Series (100 to 195 Watts) [Continued]
• Safety: Class I equipment according to IEC/EN 60950,UL 60950, EN 50155 compliant
• Flexible load distribution• Excellent surge and transient protection• Very high efficiency up to 92%• Ambient temperature range -7: –25 to 71 °C• Parallelability• Extremely low inrush current, hot plug-in• Inhibit on primary side• Extremely slim case (4TE wide) fully enclosed
Options: -9 Ambient temperature range –40 to 71 °CD Out OK outputT Current sharing (only for 3.3 and 5.1 VDC outputs)B1, B3 Cooling plate
P Series
6.5 x 4.4(3U) x 0.8(4 TE) inch164 x 111 x 20 mm
Output Adjustment RangesThe following adjustment rangesapply to single-output modelsand V1 of multi-output models.
Vout Low High
3.3 1.8 3.65.1 2.75 5.612 6.5 13.215 8.1 16.524 13.0 26.4
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Cassette > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
70
• Safety: Class I equipment with reinforcedinsulation according to IEC/EN60950, UL1950
• Universal input voltage range• Efficient input filter• Output voltage control (R) and inhibit• Surge and transient suppression circuitry• Outputs individually isolated, controlled• Outputs fully protected against overload• Ambient temperature range -7: –25 to 71°C
Options:-9 Ambient temperature range –40 to 71°CA Output voltage test socketsE Inrush current limitationP Potentiometer for Vout adjustD Save data signal
Vout Amps VAC1, 2, 3 1, 2, 3 Input Model Options
5.1 8 85 to 264 LM1001-7R -9, A, E, P, D
12 4 85 to 264 LM1301-7R -9, A, E, P, D
15 3.4 85 to 264 LM1501-7R -9, A, E, P, D
24 2 85 to 264 LM1601-7R -9, A, E, P, D
48 1 85 to 264 LM1901-7R -9, A, E, P, D
12, 12 2, 2 85 to 264 LM2320-7 -9, A, E, P, D
15, 15 1.7, 1.7 85 to 264 LM2540-7 -9, A, E, P, D
5.1, 12, 12 5, 0.7, 0.7 85 to 264 LM3020-7 -9, A, E, P, D
5.1, 15, 15 5, 0.6, 0.6 85 to 264 LM3040-7 -9, A, E, P, D
M Series
6.6 x 4.4(3U) x 1.54(8 TE) inch168 x 111 x 39 mm
Output Adjustment RangesThe following adjustment rangesapply to all single-output models.
Vout Low High
5.1 0 5.512 0 13.215 0 16.524 0 26.448 0 52.8
6.6 x 4.4(3U) x 1.54(8 TE) inch168 x 111 x 39 mm
H Series
• Safety: Class I equipment according toIEC/EN 60950, UL 1950
• Universal input voltage range• Output voltage control (R)• Built-in surge, transient suppression circuit• Outputs individually isolated• Outputs fully protected against overload• Ambient temperature range -2: –10 to 50°C• Derating up to 71°C for single output types
Options:D Save data signal
Output Amps Max Model Input 1, 2, 3 1, 2, 3 Watts 85 to 255 VAC Options
5.1 11 56 LH1001-2R D
12 6 72 LH1301-2R D
15 4.5 67 LH1501-2R D
24 3 72 LH1601-2R D
48 1.5 72 LH1901-2R D
12, 12 2, 2 48 LH2320-2 D
15, 15 1.7, 1.7 51 LH2540-2 D
5.1, 12, 12 5, 0.7, 0.7 42 LH3020-2 D
5.1, 15, 15 5, 0.6, 0.6 43 LH3040-2 D
Output Adjustment RangesThe following adjustment rangesapply to single-output models.
Vout Low High
5.1 0 5.612 0 13.215 0 16.524 0 26.448 0 52.8
H Series (42 to 72 Watts)
M Series (40 to 50 Watts)
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Cassette > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
71
S Series
6.6 x 4.4(3U) x 2.4(12 TE) inch168 x 111 x 60 mm
• Safety: Class I equipment according to IEC/EN 60950, UL 60950
• LS 1000/2000 no PFC, fin 47 to 440 Hz• Output voltage control (R) and inhibit• Outputs open- and short-circuit proof• Ambient temperature range -7: –25 to 71 °C• No derating over temperature
Options:-9 Ambient temperature range –40 to 71 °CE Inrush current limitation1
D Save data signalP Potentiometer for Vout adjustT Current sharing
B1, B2 Cooling plateV AC fail signal according to VME-Standard
(5.1 V models only)1 Option E is mandatory for S Series models with the
-9 option.
Vout Amps1, 2 1, 2 VAC Input Model PFC Options
5.1 16 85 to 264 LS1001-7R no -9, E, D, V, P, T, B1, B2
5.1 16 85 to 255 LS4001-7R yes -9, E, D, V, P, T, B1, B2
12 8 85 to 264 LS1301-7R no -9, E, D, P, T, B1, B2
12 8 85 to 255 LS4301-7R yes -9, E, D, P, T, B1, B2
15 6.5 85 to 264 LS1501-7R no -9, E, D, P, T, B1, B2
15 6.5 85 to 255 LS4501-7R yes -9, E, D, P, T, B1, B2
24 4.2 85 to 264 LS1601-7R no -9, E, D, P, T, B1, B2
24 4.2 85 to 255 LS4601-7R yes -9, E, D, P, T, B1, B2
12, 12 4, 4 85 to 264 LS2320-7R no -9, E, D, P, T, B1, B2
12, 12 4, 4 85 to 255 LS5320-7R yes -9, E, D, P, T, B1, B2
15, 15 3.2, 3.2 85 to 264 LS2540-7R no -9, E, D, P, T, B1, B2
15, 15 3.2, 3.2 85 to 255 LS5540-7R yes -9, E, D, P, T, B1, B2
24, 24 2, 2 85 to 264 LS2660-7R no -9, E, D, P, T, B1, B2
24, 24 2, 2 85 to 255 LS5660-7R yes -9, E, D, P, T, B1, B2
Output Adjustment RangesThe following adjustment rangesapply to all models.
Vout Low High
5.1 0 5.612 0 13.215 0 16.524 0 26.448 0 52.8
S Series (81 to 100 Watts)
• Safety: Class I equipment according to • LK 1000/2000 no PFC, fin 47 to 440 HzIEC/EN 60950, UL 1950 • Output voltage control (R) and inhibit
• Universal wide input voltage range (LK models) • Input over- and undervoltage lockout• Efficient input filter
Options:-9 Ambient temperature range
–40 to 71 °CE Inrush current limitation1
D Save data signalP Potentiometer for Vout adjustT Current sharingB1, B2 Cooling plateV AC fail signal according to
VME-Standard (5.1 V models only)1 Option E is mandatory for K Seriesmodels with the -9 option.
Vout Amps VAC1, 2 1, 2 Input Model PFC Options
5.1 25 85 to 264 LK1001-7R no -9, E, D, V, P, T, B1, B2
5.1 25 85 to 255 LK4003-6R yes -9, E, D, V, P, T, B1, B2
12 12 85 to 264 LK1301-7R no -9, E, D, P, T, B1, B2
12 12 85 to 255 LK4301-7R yes -9, E, D, P, T, B1, B2
15 10 85 to 264 LK1501-7R no -9, E, D, P, T, B1, B2
15 10 85 to 255 LK4501-7R yes -9, E, D, P, T, B1, B2
24 6 85 to 264 LK1601-7R no -9, E, D, P, T, B1, B2
24 6 85 to 255 LK4601-7R yes -9, E, D, P, T, B1, B2
12, 12 6, 6 85 to 264 LK2320-7R no -9, E, D, P, T, B1, B2
12, 12 6, 6 85 to 255 LK5320-7R yes -9, E, D, P, T, B1, B2
15, 15 5, 5 85 to 264 LK2540-7R no -9, E, D, P, T, B1, B2
15, 15 5, 5 85 to 255 LK5540-7R yes -9, E, D, P, T, B1, B2
24, 24 3, 3 85 to 264 LK2660-7R no -9, E, D, P, T, B1, B2
24, 24 3, 3 85 to 255 LK5660-7R yes -9, E, D, P, T, B1, B2
24, 24 4.8, 4.8 187 to 255 LKP5662-7R yes E, D, P, T, B1
24, 24 5.2, 5.2 187 to 255 LKP5660-7R yes E, D, P, T, B1
24, 24 5.8, 5.8 187 to 255 LKP5661-5R yes E, D, P, T, B1
K & KP Series (127 to 278 Watts)
6.6 x 4.4(3U) x 3.2(16 TE) inch168 x 111 x 80 mm
K Series
Output Adjustment RangesThe following adjustment rangesapply to all models.
Vout Low High
5.1 0 5.612 0 13.215 0 16.524 0 26.4
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
Cassette > AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
72
Cassette > Battery Chargers
Battery Nominal Nominal OutputModel Voltage Watts Output Voltage Amps
LM1781-7RD5 12 50 12.84 3.6
LH1781-2R 12 70 12.84 5
LK4740-7R 12 150 12.84 10
LM1782-7R 24 50 25.68 1.8
LH1781-2R 24 70 25.68 2.5
LK5740-7R 24 150 25.68 2.7
LKP5740-7R 24 250 25.68 4.5
LM1783-7R 36 50 38.52 1.2
LH1781-2R 36 70 38.52 1.67
LM1784-7R 48 50 51.36 0.9
LH1781-2R 48 70 51.36 1.25
LK5740-7R 48 150 2 x 25.68 2 x 2.7
LKP5740-7R 48 250 2 x 25.68 2 x 4.5
LM1785-7R 60 50 64.2 60.72
LH1781-2R 60 70 64.2 1
Please refer to data sheets for availability of EMI options, temperature sensoroptions, and safety agency certifications.
Other battery chargers are available in DIN-Rail mount packages; refer to the DIN-Rail Mount Section. Contact factory for availability.
6.6 x 4.4(3U) x 1.54(8 TE) inch168 x 111 x 39 mm
H Series
M Series
6.6 x 4.4(3U) x 1.54(8 TE) inch168 x 111 x 39 mm
6.6 x 4.4(3U) x 3.2(16 TE) inch168 x 111 x 80 mm
K Series
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Systems Overview
73
Site-specific solutions, ranging from power shelves toenvironmentally-controlled outdoor power cabinets, can beconfigured from a comprehensive array of rectifiers,controllers, interfaces, software, and distribution modules.
Power-One’s broad range of indoor and outdoor DC powersystems utilize modular architectures to provide flexiblesolutions that are cost-effective and scalable.
This industry-leading array of rectifiers, controllers,distribution systems, communications interfaces, andsoftware is augmented by customer-focused productapplication teams.
These locally-based DC power experts have access toPower-One’s global engineering and manufacturingresources, enabling rapid design and configuration ofcomplete DC power systems, including site-specificrequirements such as battery systems and environmentallycontrolled enclosures.
Modular Solutions, Global Support
Increasing the Profit Generating Potential of Communications Equipment
Increasing the profit potential of communications equipment isaccomplished by a unique combination of advantages thatlower power-system acquisition and operating costs:• Power-One’s global operations provide the economies of
scale needed to facilitate very competitive initial acquisitioncosts, increasing the ROI for systems being powered.
• Industry-leading rectifier power densities reduce the spaceneeded for power; providing more space for revenuegenerating equipment.
• In addition to lowering the amount of electricity required byrectifiers, increased efficiencies reduce dissipated heat;reducing the power required for site-level cooling systems.
• High MTBFs increase the uptime for high-availabilityequipment and lower maintenance costs.
• A comprehensive range of communications interfaces andsoftware simplifies remote monitoring and control; reducingsupervisory and management costs.
Continued on Next Page
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Systems Overview
74
Applications Series and Features
Small Systems (up to 5kW)
• Broadband access• CPE• Data networks• Micro cells• IP routers• WiMax• Optical nodes
Galero, 48V• 3U and 6U shelf systems.• RS232 and SNMP compatible.• Convection cooled.
Aspiro, 48V• Compact 1RU & 2RU 300mm ETSI footprint.• Flexible load and battery management options.• Global solutions support 85 to 300Vin operation,
from -40 to +65°C ambient, without derating.
Medium Systems(up to 36kW)
• Wireless macro sites • Transmission• WiMAX• Optical nodes
Xscend, 24V & 48V• Modular shelf systems include rectifiers,
controllers, and distribution circuit breakers.• NEBS certified systems up to 32 kW / 640 A.• Shelves for 19” and 23” racks/cabinets; 300 mm ETSI compliant.• Compact 2U rectifier shelves maximize space for revenue-generating equipment.
PPS16, 48V• Modular shelf and cabinet systems.• Shelves available for 19” and 23” racks/cabinets.• 600 mm ETSI compliant.• Up 36 kW / 750 A rectifier and 720 Ah battery
capacity per cabinet.
Medium Systems(up to 400kW)
• Central office• Data centers• Mobile switch sites
Forza, 48V• Modular scalable cabinet solutions facilitate live
expansion of rectifiers and distribution shelves.• Up to 400 kW / 8300 A.• Top and bottom cable entry for overhead or
raised-floor sites.• Flexible modular low/high ohmic and fuse-load
distribution options.
Standard Product Platforms Accelerate Value-Added Solution AvailabilityA comprehensive array of power system platforms has beenspecifically designed to accelerate the availability of value-added site-level solutions. Power-One’s combination of globalresources and local customer support can cost effectivelyfacilitate a multitude of value-added solutions, including:• Distribution systems; bus bars, fuses, and circuit breakers.
• Complete battery systems.• Configuration of controllers and communications interfaces.• Environmentally-controlled outdoor power cabinets.• Lead-free solder and lead-solder-exempted RoHS
compliances.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Systems Overview
75
Applications Series and Features
Large Systems(up to 650kW)
• Central office• Data centers• Mobile switch sites
Magnum 120, 48V• Provides up to 12000A with 2000A per bay.• Three-phase 380-480V nominal input
(50 or 60 Hz) with no neutral.• Advanced battery management capability.• NEBS approved.
Outdoor Solutions
• Wireless base stations• Remote radio heads• Transmission• Optical networking• WiMAX• FTTN
Mini• Pole-mounted enclosure system.• Lightweight and easy to install.• Passive cooling for maximum system availability.
Midi• Flexible battery cabinets optimize the size
of the overall system based on Ah requirements.• Separate battery and power compartments.• Heat-exchanger cooled equipment cabinet.• Up to 9 kW / 188 A rectifier and 680 Ah battery
capacity per cabinet.• High security multi-point locking mechanism.
PODS 16
• Heat Exchanger or air-conditioner climatecontrol options.
• Flexible power shelf configurations.• High security multi-point locking mechanism.• Provides environmental management for valuable
network equipment such as wireless base stations.
Inverters
• Data centers• Networking• Telecom sites with
AC powered equipment
SLI 1500
• 24/48VDC input, 115/230VAC output options.• Constant current sink for extended battery life.• Parallel redundant capability with current share and synchronization.• Single and three-phase configurations; true sine wave output.• 93% conversion efficiency.• Internal static switch option.
Continued on Next Page
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Systems Overview
76
PowCom Software
Power Network Interface
PowCom™ is a windows-based software which interfaces toPower-One controllers allowing configuration, control anddiagnostics of the power system, batteries, and ancillary siteequipment such as air-conditioning and backup generators.Multiple-level password control ensures that operations andmaintenance personnel have the appropriate authorizations.Powcom offers data logging of user selected systemoperating parameters such voltages, currents, and alarmsand can be configured for automatic battery testing.Additional features include:• Complete reporting of system status in one location with all
available system parameters available in a single window.• Readily-displayed messages for present and disappearing
alarms, including the time and date of appearance.• User-selectable alarm parameters.• Data logging of the last 40 events.• Continuous logging of voltages, currents, and alarms
The Power Network Interface (PNI) facilitates accessing aPower-One controller remotely over an Ethernet network.The PNI uses SNMP protocols to send real time alarms andmessages to standard Network Management Systems suchas HP Openview. The controller can then be accessed via aweb browser or PowCom for more detailed site diagnostics todetermine an appropriate course of action.
GUI screens include a graphical presentation of battery testdata, which simplifies comparison with ongoing test resultsfor battery integrity trend analysis.
The Power Network Interface significantly simplifiesmonitoring multiple sites from a central location.
On-Site ServicesPower-One’s comprehensive range of services are tailored tothe specific requirements of your site and network, and cansignificantly contribute to the integrity of your mission criticalpower systems. Power-One’s services include:• Site design and construction; including site surveys,
requirements analysis, factory and site acceptance tests,installation, commissioning, and project management.
• Management of activities related to equipment upgrades,rentals, replacements, disposal and recycling.
• 24/7/365 support, available online and on site.
• Preventative maintenance programs that can improvenetwork availability by proactively identifying potentialproblems, and providing expert guidance on schedulingequipment upgrades and replacements.
• Extended service and hardware warranties.• A comprehensive range of training courses, customized to
meet specific customer needs.• Selection and provisioning of the best battery for your
application; including vented, sealed, NiCad, and lithium.
Control and MonitoringPower-One’s sophisticated controllers, monitor and managepower systems, and ancillary site equipment, in real time.Network interfaces & modems allow remote diagnostics overstandard network technologies (PSTN, internet, Ethernet orcellular) and protocols (TCP/IP, SNMP, SMS etc). This real
time & historical diagnostic data ensures maximum networkavailability and reduces operations and maintenanceexpenditures. Power-One controllers also have a webserveroption which provide web-browser-based access without theneed for client-based software.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Intelligent Monitoring & Control Capabilities
77
Intelligent Motor Controls
Power-One’s advanced algorithms respond to dynamicinductive-load conditions by providing motors with power thatis optimized to save energy and provide enough torque to getthe job done. In addition, Power-One’s motor-controlsolutions are economical, reliable, and feature industry-leading packaging densities.
Turnkey applications support also includes capabilities todesign and manufacture embedded variable-speed motordrives, temperature control boards, user interfaces, andsystem-wide interfaces that manage all of the sensors andmotors within a host product.
Power-One’s industry-leading digital-control design andmanufacturing capabilities can provide your system withimproved performance, increased reliability, reduced energyconsumption, and enhanced diagnostic and reportingcapabilities. These innovative solutions utilize advanced
digital technologies to monitor and control a wide range ofapplications, such as power distribution, public lighting, andelectric motors. Please contact your local Power-Onerepresentative to discuss your application.
HIQgrid Digital Control System
The HIQgrid™ is a low-bandwidth communications platformthat can be used to communicate through power lines;facilitating remote monitoring and control of virtually anyinfrastructure system that utilizes power.
Because this innovative platform is scalable up to hundredsof thousands of control points; it can significantly increaseoperational efficiencies by connecting devices from differentsystems (such as streetlights, traffic lights, distributiontransformers, etc.) to a common control interface.
i.illumination
The HIQgrid™ i.Illumination™ Streetlight Monitoring andControl System provides remote control, optimizes uptime,extends lamp life, reports the need for lamp replacement,and reduces street-lighting costs.
Digital sensing and control units, positioned along utilitypower lines, capture and relay coded data to collectionterminals. Remote collecting units then communicate thedata via ISDN, Ethernet, GSM, GPRS or microwave toservers running geographic information software; providingthe capability to pinpoint equipment in need of maintenanceanywhere on the utility grid.
i.energy i.displayi.home
i.crossing
i.parking
i.illumination
Common controlinterface
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Alternative Energy Inverters
78
Power-One offers a complete range of photovoltaicproducts for use in indoor and outdoor grid-tiedapplications.These products provide industry-leadingenergy-harvesting efficiencies throughout a broadrange of operating conditions.
Comprehensive feature sets include:• Compact and attractive designs.• Advanced MPPT algorithms for greater
energy harvesting.• Robustly engineered for dependable, long-
life performance.• Extremely user-friendly interfaces.• Integrated data logger.
Aurora Photovoltaic Inverters
The Aurora® Series are Power-One’snewest, most powerful, and feature-rich PV inverters:• Transformerless designs deliver
industry-leading efficiencies; up to97% (96.5% Euro and CEC).
• Typically less than 3.5% totalharmonic distortion; achievedthrough the use of high-frequencyswitching techniques.
• True sine wave outputs.• Laptop-free configuration capabilities
via front-panel buttons.• Two-source circuit inputs, each with
its own MPPT, support installationswith multiple arrays oriented indifferent directions.
• High overload capabilities.
Please visit www.power-one.com for additional PV inverter specifications and country-specific-compliance information.
Application Solution EuropeNorth
America
GridTie
Indoor
3600WResidential
PVI-3600 • •3300W
ResidentialPVI-3300 •
2000WResidential
PVI-2000 •
GridTie
Outdoor
6000WCommercial& Residential
PVI-6000-OUTD • •
5000WCommercial& Residential
PVI-5000-OUTD • •
3600WResidential
PVI-3600-OUTD •3600W
ResidentialPVI-3600-OUTD-F
Internal Fan • •3300W
ResidentialPVI-3300-OUTD-F
Internal Fan •3000W
ResidentialPVI-3000-I-OUTD
Low Frequency Isolation • •
2000WResidential
PVI-2000-OUTD •PV Monitoringand Control
PVI-AEC • •
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Alternative Energy Inverters
79
Application Solution EuropeNorth
America
GridTie
Outdoor
7200WCommercial& Residential
PVI-7200-Wind-InterfaceUsed with PVI-Series
wind inverters.
• •
6000WCommercial& Residential
PVI-6000-OUTD-W • •
4000WResidential
PVI-4000-Wind-InterfaceUsed with PVI-Series
wind inverters.
• •
3600WResidential
PVI-3600-OUTD-F-W • •
IndoorStandAlone
5000WCommercial& Residential
MWI • •
Aurora & MWI Wind Inverters
Power-One provides grid tie and stand-alone small-wind-power inverters. The Aurora® family of inverters providespower conditioning for grid-tie applications. MWI (Multi-mode
Wind Inverter) products can be used in both stand-alone andgrid-connected applications, and also as an interface forhybrid power systems.
Multimode-input capabilities provide MWI products with industry-leadingconfiguration flexibility in stand-alone applications. In addition to a smallwindmill, the MWI can be connected to an auxiliary photovoltaic array, agenset, and storage batteries.• Up to 90% efficiency from renewable source to AC load • Control software facilitates optimizing the inverter to the specific
power curve of the windmill being used.• True sine wave output, 230V single-phase, or 115V split-phase.• 50 or 60 Hz operation.• Front-panel LCD display simplifies set up and monitoring.
Please visit www.power-one.com for additional wind inverter specifications and country-specific-compliance information.
Aurora® Wind Inverters share the same feature-rich, robust designsutilized by Aurora® PV Inverters. Aurora® Wind Interfaces conditionthe output of a micro-wind generator for use with an inverter;eliminating the need for any additional rectification. Other industry-leading features include:• 99.4% conversion efficiency at rated power.• Compatible with a 3-phase input from a PMG.• Ratings up to 7 kW.• Fused wind input.• Automatic brake function above 530 VDC.• External brake resistor options.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Technical Articles Available at www.power-one.com
80
This paper, presented at the 2006 EPA Energy Star Serverand Data Center Conference, demonstrates howimplementing intelligent/adaptive and activity-basedmethodologies could reduce power losses by 20%; providingannualized savings of $23K to $43K, depending on data-center size. Intelligent/adaptive management continually
adjusts the internal operating parameters of AC-DC frontends and DC-DC converters, in order to optimize efficienciesand key performance parameters. Activity-basedmanagement reduces power dissipation and consumption bycontrolling the intermediate bus voltage, clock frequencies,and cooling fan speeds.
The summaries listed below are only a few of the manytechnical articles that are available at www.power-one.com.These articles are formatted as PDFs and may be
downloaded by selecting the Technical Articles link from theTech Reference menu on top of the home page, or byentering the site search keys referenced below.
Reducing IBA Power Dissipation and Consumptionwith Adaptive/Intelligent Control and Power Management Site Search Key: tech106
The operational goal of EN50155 is for electronics in rail carsto be able to operate 24 hours a day for 20 years, orapproximately 175,000 hours. This is accomplished bydefining requirements for practically every environmentalaspect, including input-voltage fluctuations and transients,
ambient temperature ranges, shock and vibration, and fogand salt spray. The purpose of this article is to provide asummary of the EN50155 specifications that most affectpower supplies and describe some of the design techniquesthat were used to meet these requirements.
Meeting EN50155 Railway Requirements Site Search Key: tech105
This article provides a reference design for a multiple-outputboard-level point-of-load power system utilizing Power-One’snon-isolated Z-1000 No-BusTM POL Converters. Designingwith these digital POL converters is as easy as assembling a
LEGO model. It requires neither years of analog designexperience (although it does not hurt) nor intimate knowledgeof Z-transformations.
Reference Design of a Power System with No-Bus™ POL Converters Site Search Key: tech104
As the wireless revolution advances at break-neck speeds,wireless infrastructure continues to be an important area ofdevelopment. WiMAX has emerged as the standard of choicefor a new generation of wireless connectivity. A WiMAX basestation contains a complex array of high-speed digital signal
processing, memory, I/O circuitry, and noise-sensitive RFtransceivers. The power system requirements of such anapplication are not trivial to say the least and almost alwaysrequire integration of power conversion and powermanagement functions.
Selecting a Power Solution for WiMAX Applications Site Search Key: tech103
Board designers have been contemplating the question ofwhether to buy modular Point-Of-Load (POL) converters ordesign their own since…well, as long as circuit boards haveexisted. Based on the premise that the initial acquisition costsof a PWM IC, a couple of FETs, and a few passives are less
than a POL module, many designers have made the decisionto implement discrete solutions. The purpose of this article isto examine the many other factors that need to be taken intoaccount when making a decision to design or buy board-levelpoint-of-load power solutions.
To Design or Buy- That is the Question Site Search Key: tech102
Intelligent Platform Management Interface (IPMI) is an openstandard that defines common interfaces for remotemonitoring, logging, and control of server, networking andtelecommunications platforms. IPMI is designed to allow
enterprise-class systems to be managed remotely,independent of the operating system, even if the system isdown. This article examines the options that are availablewhen designing power systems for IPMI applications.
Powering IPMI- Intelligent Platform Starts with Intelligent Power Site Search Key: tech101
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life supportsystems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president ofPower-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the datemanufactured. Specifications are subject to change without notice.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
www.power-one.com
AC-DC Front Ends
AC-DCEmbedded
CompactPCICassetteDIN Rail
DPA & IBABricks
Y-SeriesAnalog POLs
Z-SeriesDigital POLs
ZM7300 Digital Power Managers
Any Voltage • Any Current Any Power Architecture
Digital Point-Of-LoadPower Management
and Conversion
Analog Point-Of-Load Conversion
Board-Level DPA and IBA
System-Level DPA and IBA
CentralizedArchitectures
Industrial andTransportation
CompactPCI
I2C compatible Z-7000 Series reduces power system components, traces,
and development time by 90%.
Pin-strapable Z-1000 POLs provide digitalpower management capabilities without
software or external controllers.
Y-Series POL converters are available inindustry-standard and high-performance
Power-One footprints.
The industry’s broadest range of bricks, from 1/16 to full, includes bus converters,
multi-output, and PoE solutions.
AC-DC front ends in hot-swap power shelf and chassis-mount configurations.
Single and multiple output modelsinclude flexible modular solutions.
Rugged cassette style andDIN-Rail mount AC-DCand DC-DC products.
AC-DC and DC-DC in3U and 6U form factors.
Applications Solutions
Power-One is a registered trademark of Power-One, Inc.
DPA & IBABricks
Y-SeriesAnalog POLs
Z-SeriesDigital POLs
ZM7300 Digital Power Managers
Any Voltage • Any Current Any Power Architecture
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Industry-Leading EfficienciesAdvanced power-conversion topologies
reduce energy consumption andcontribute to lower energy costs
ISO9001 and ISO14001Management systems are certified tointernationally-recognized operational
and environmental standards.
Power-One is Designing ecointo Power conversion
Optimized Bus Voltages Reduce Conversion and I2R Losses
48Vnominal 12Vnominal
Power-One’s broad range of products, many with adjustable outputs, allows the selection ofoptimized bus voltages that can reduce I2R losses and increase power conversion efficiencies.
Please visit www.power-one.com for additional information.
Power-One, maXyz, No-Bus, Z-One, Z-One Digital IBA, and Z-POL
are trademarks and/or logos of Power-One, Inc.
European Union RoHSPower-One’s unique two-tiered EU RoHS strategyprovides products inboth lead-free solder andlead-solder-exemptedversions. Please refer toour data sheets for model-specific compliance options.
RoHS China Power-One will meet the
initial requirements ofChina RoHS, for selectedproducts, by includingproduct and packaging
marking and disclosuretables. Please visit our website for further details.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com