Hitachi Air Conditioning Product Catalogue Engineering for tomorrow. And the tomorrow after that. www.hitachiaircon.com | www.hitachiheating.com Models Split Systems Set Free VRF Systems Close Control Ventilation Domestic Heating Samurai Chillers Control Systems
Transcript
Page 1: 2012 A5 Product Catalogue FULL (3)

Hitachi Air ConditioningProduct Catalogue

Engineering for tomorrow. And the tomorrow after that.

www.hitachiaircon.com | www.hitachiheating.com

Models

Split SystemsSet Free VRF Systems Close Control VentilationDomestic HeatingSamurai Chillers Control Systems

Page 2: 2012 A5 Product Catalogue FULL (3)

Page

58 - 65 Set Free VRF Systems Mini 2-pipe Side Flow 2-pipe Modular 2 and 3-pipe Combinations CH Boxes System Free indoor units System Free Accessories/Pipe Kits

66 - 69 Close Control Twin DC Inverter

70 - 75 Ventilation KPI Total Energy Recovery KPI Heat Recovery Active Total Energy Recovery Econofresh Kit

76 - 83 Domestic Heating Yutaki-M Monobloc air-to-water heat pump Yutaki-S Split type air-to-water heat pump Accessories

84 - 87 Samurai Chillers Air Cooled Water Cooled Condenserless Cooling Only

88 - 91 Control Systems and Accessories Individual controls Group controls BMS Interface controls Accessories

92 - 116 Helping You Training Warranty Alarm Codes Wiring Diagrams DIP switches Conditions of Sale

Contents

Page

08 Product Range

10 - 17 Wall Mounted RAC S-Series RAC Shirokuma RAC Summit Utopia ES Utopia IVX Utopia Centrifugal

18 - 25 Cassettes RAC Monozone (600x600) Utopia ES 4-Way Utopia ES 2-Way Utopia IVX 4-Way Cassette/2-Way Cassette Utopia IVX Centrifugal 4-Way Cassette/2-Way Cassette

26 - 31 In the Ceiling (ducted) RAC Monozone Utopia ES Utopia IVX Utopia IVX Centrifugal

32 - 37 Ceiling Suspended Utopia ES Utopia IVX Utopia IVX Centrifugal

38 - 43 Floor Mounted RAC Shirokuma RAC NX2 Utopia ES

44 - 49 Multizone Multi Split Systems Multizone Outdoor Units Multizone Indoor Units Combinations RAC Accessories

50 - 57 Twin, Triple and Quad Splits Utopia ES, Centrifugal and IVX Systems

Utopia ES Utopia IVX Utopia IVX Centrifugal System Free Indoor Units System Free Accessories/Pipe Kits Utopia AHU Interface Controllers

Page 3: 2012 A5 Product Catalogue FULL (3)

Why Hitachi?

With so much to choose from in the market, here are some key reasons to buy from Hitachi’s extensive range of products:

RAC

Our market-leading S-Series wall mounted range has a high COP of 6.13 and high EER of 6.0 for low running costs.

Utopia

No outdoor space, listed building or restrictive covenants? Install Utopia Centrifugal - now with IVX individual control - the Outdoor that’s an Indoor.

Set Free

Comfort protection function across the range – so you won’t hear complaints about cold draughts!

Ventilation

Capacities of up to 2000m3 per hour from a unit that’s less than 650mm high (the lowest height on the market); a compact solution where installation space is limited.

Domestic Heating

Market-leading COP combined with great energy savings (5kW output from 1kW input) – fantastic news for the domestic market when fuel costs are on the increase.

Samurai

Supremely reliable and precise control to within +/- 0.5ºC.

Control Systems and Accessories

H-LINK II across the entire Hitachi product range means you can use Hitachi system free controls for any mix of products.

Heating Manufacturer of the Year “ The judges felt Hitachi provided an excellent submission, a great product and the way forward.”Hitachi’s Yutaki M Heat Pump

Page 4: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 5

Flexibility built inLook for the System Free logo on all pages featuring our System Free indoor units which can be combined with outdoor units from our Utopia splits or Set Free VRF ranges for the ultimate in flexibility.

Energy saving technologyhttp://etl.decc.gov.uk/etl

Many Hitachi systems have an energy rating of A and are listed on the Energy Technology register: making them eligible for 100% first year enhanced capital allowances. (System cost and reasonable cost of installation).

Quality controlHitachi’s Japanese factories and its overseas affiliates have acquired International Standard Quality Management System ISO9001 and ISO14001 authorisation. The factories perform thorough product quality control using various environmental tests. Hitachi Room Air Conditioning indoor and outdoor units are manufactured according to this ISO certification system.

Hitachi products all carry the necessary ‘CE’ declaration markings, and also feature in the extensive Eurovent Listing programme. Listing in the Eurovent directory helps ensure peace of mind for the installer and the end user, as it certifies the important operating parameters and performance of the units.

World-renowned technologyHitachi manufactured the first screw and scroll compressors in the world (230 patents on 6 components). The performance of Hitachi air conditioning products is greatly improved by the high efficiency high pressure scroll compressors. Hitachi pioneered ‘DC’ Inverter PAM driven Room Air Conditioners and uses this technology to drive its compressors and fans.

Nominal & UK Conditions

Nominal conditions coolingIndoor temperature 27ºC DB, 19ºC WBOutdoor temperature 35ºC DB , 24ºC WB

Nominal conditions heatingIndoor temperature 20ºC DBOutdoor temperature 7ºC DB, 6ºC WB

UK ConditionsIndoor temperature 23ºC DB, 16ºC WBOutdoor temperature 30ºC DB

S Y S T E MFREE

Page 5: 2012 A5 Product Catalogue FULL (3)

Why Hitachi?

System Free – complete flexibilityHitachi is particularly proud of its System Free concept of indoor units, providing the flexibility to combine indoors with outdoor

units from either the Utopia split systems or Set Free VRF ranges. This gives you enormous scope when planning your climate

solution and facilitates an optimum room climate for all areas.

Utopia outdoor units

Hitachi’s Utopia Split systems range

is available in capacities from 5.0kW

to 33kW. Models include Utopia ES

and IVX, which have a common

cabinet appearance allowing them

to be installed together. The Utopia

Centrifugal units are designed to be

installed indoors with field supplied

ductwork. System free indoor units

and controls are compatible across

the entire range.

Set Free outdoor units

Hitachi’s Set Free range of air

conditioning systems with variable

refrigerant flow (VRF) is available

in capacities from 8kW to 165kW.

Models include Mini 2-pipe,

Side Flow 2-pipe and Modular

2 or 3-pipe system allowing heat

pump or heat recovery options to

suit customer requirements. System

free indoor units and controls are

compatible across the entire range.

Indoor units

Wall-mounted

Cassette

Ceiling-suspended

In the ceiling

Floor-mounted

Total heat exchanger

System Free remote controls and accessories

System free controls can also be used for the RAC* range using PSC-6RAD adapter.

PC-ARTPC-ARF

* excludes S-Series

S Y S T E MFREE

Page 6: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 7

Functions may vary among the remote controls.

BMS: MODBUS

KNX

CS NET WEB

BACNET

HARC LONWORKS®

CENTRALISED: CS NET WEB

Optional touchscreen

TS002-UK

GROUP: PSC-A64S / PSC-A1T / PSC-A64GT

LOCAL: PC-ARF / PC-ART / PC-ARH / PC-LH3A

Hitachi products also benefit from the versatile range of

System Free controls to fulfil different requirements. The

extensive range includes a variety of wired and wireless

remote controllers as well as the option of different group

controllers. It is also possible to connect all Utopia Splits,

Set Free VRF and Samurai Chillers to Hitachi’s CS Net Web

which provides centralised or remote access control via an

internet connection.

Remote controls

Utopia Split systems Set Free VRF

ES (Simultaneous Operation)

IVX (Individual Operation)

Centrifugal (Simultaneous/individual Operation)

Compatible with System Free indoor units

FS(V)(Y)N2E Mini 2-pipe

FSNM Side Flow 2-pipe

FSXN Modular 2 or 3-pipe

Page 7: 2012 A5 Product Catalogue FULL (3)

Product Range

Split Systems (kW) 2.0 2.5 3.5 5.0 6.0 7.1 8.0 9.0 10.0 12.5 14.0 20.0 25.0 30.0

Wall Mounted

Cassettes

In the Ceiling (ducted)

Ceiling Suspended

Floor Mounted

Multizone Multi Splits

Utopia ES

Utopia IVX

Utopia Centrifugal

A COP 6.13

COP 4.55

COP 4.17

COP 3.62

COP 4.30

COP 4.11

A

A

A

A

A

COP 3.10B

COP 4.55A

COP 4.47A

Set Free VRF (kW) 8 11 14 16 22 28 33 40 45 50 56 63 69

Mini 2-pipe

Side Flow heat pump (2-pipe)

Modular heat pump (2-pipe)

Modular heat recovery (3-pipe)

Samurai (kW) 112 130 156 178 206 260 312 356 400 412

Air Cooled (Cooling Only)

Air Cooled (Heat Pump)

Water Cooled

Conderserless

Ventilation (m3/hr)* 250 500 800 1000 1500 2000

Total Energy Recovery

Heat Recovery

Active Total Energy Recovery

*Econofresh also available

Page 8: 2012 A5 Product Catalogue FULL (3)

73 80 85 90 96 101 107 113 118 124 130 135 140 145 150

468 534 618 712 824 890 1030

For full details, refer to Technical Manual

COP 4.17

COP 4.17

A

A

A COP 4.14

A COP 4.55

Domestic Heating (kW) 5 8 10 12.5 14 20 24

Yutaki - M

Yutaki - S

A COP 4.50

COP 5.01A

Close Control 56

Twin DC Inverter

A ESEER 3.52

ESEER 3.45A

A ESEER 4.86

ESEER 4.32A

A EER 2.80

Page 9: 2012 A5 Product Catalogue FULL (3)

Wall Mounted

Features and Benefits

All RAC Wall mounted units

RAC S-Series

33 per year*

* Based upon 500 hours of 100% run time with a cost of 8 pence / 16 cents per kW/hr on 2.5 kW unit

RAC Shirokuma

compliment any interior

RAC Summit

Utopia Wall Mounted

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Page 10: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 11

Product Summary S-Series RAS 18~35SX8

Shirokuma RAS 25~50WX8(W)(B)

Summit RAS 18~80FH6/FH7/YH5A

Utopia ESRPK 2~4.0FSN2M

Utopia IVXRPK 3~4.0FSN2M

Utopia CentrifugalRPK 3.0FSN2M

Nominal Cooling Capacity (kW) 1.8 ~ 3.5 2.5 ~ 5.0 2.0 ~ 8.0 5.0 ~ 10.0 7.1 ~ 10.0 7.1

Nominal Heating Capacity (kW) 2.1 ~ 4.2 3.4 ~ 6.3 2.5 ~ 9.3 5.6 ~ 11.2 8.0 ~ 11.2 8.0

Refrigerant R410A R410A R410A R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter

Operating Range¹ (Cooling) -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -5ºC / +43ºC

Operating Range (Heating) -20ºC / +21ºC -15ºC / +21ºC -15ºC / +21ºC -10ºC / +15ºC (*) -20ºC / +15ºC -15ºC / +15ºC

Std. Remote Controller Type Infra Red Infra Red Infra Red Wired or Infra Red Wired or Infra Red Wired or Infra Red

Remote Control Timer - 24hr or 7 Day

Option24hr or 7 Day

Option24hr or 7 Day

Option24hr or 7 Day

Option24hr or 7 Day

Option

¹ Selected Models (*) -15ºC 2.0/2.5 models

Page 11: 2012 A5 Product Catalogue FULL (3)

RAC S-Series

Outdoor Units

Wall Mounted

For full technical details refer to Technical Manual

RAS 18SX8 RAS 25SX8 RAS 35SX8

Nominal Capacity (Min ~ Max) (kW)Cooling 1.8 (0.5~2.4) 2.5 (0.5~3.4) 3.5 (0.5~4.1)

Heating 2.1 (0.6~4.4) 3.2 (0.6~6.1) 4.2 (0.6~7.6)

UK Cooling Capacity (kW)Total 1.9 2.7 4.3

Sensible 1.7 2.4 2.8

EER/COPCooling 6.00 5.38 4.19

Heating 6.13 5.47 4.80

Energy LabelCooling A A A

Heating A A A

Indoor Sound Pressure Level dB(A)Cooling 38/32/26/20 42/34/28/20 43/34/28/20

Heating 39/33/27/23 42/35/30/20 44/35/30/20

Indoor Fan (m3/min)Cooling 8.0/6.2/4.5/3.5 11.5/8.3/7.2/5.2 11.9/8.8/8.1/5.2

Heating 9.5/7.0/5.5/3.3 12.5/9.0/8.0/5.3 13.4/10.2/9.0/5.3

Dimensions (mm) & Weight (kg)

Height 298

Width 793

Depth 233

Weight 11.5

RAC 18SX8 RAC 25SX8 RAC 35SX8

Outdoor Sound Pressure Level dB(A)Cooling 45 45 46

Heating 46 45 46

Dimensions (mm) & Weight (kg)

Height 570

Width 750

Depth 288

Weight 36

Operating Range (ºC)Cooling -10 ~ +43

Heating -20 ~ +21

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)

Gas 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)

Piping (m)

Length 20

Lift 10

Pre-charged 20

Power Supply 230V 1ph 50Hz

Power to Indoor & Outdoor

Interconnecting Cables No. 4 4 4

Starting Current (A) 5.8 5.8 6.2

Running Current (230v) (A)Cooling 2.87 2.87 4.35

Heating 3.72 3.72 4.49

Recommended Fuse Size (A) 16 16 16

RAC-SX8

RAR-3R5 RAS-SX8

Page 12: 2012 A5 Product Catalogue FULL (3)

For full technical details refer to Technical Manual

Outdoor Units

Wall Mounted

Hitachi Product Catalogue | 13

RAC Shirokuma

RAC-WX8

RAS-WX8 RAS-WX8

RAS 25WX8 (W/B) RAS 35WX8 (W/B) RAS 50WX8 (W/B)

Nominal Capacity (Min ~ Max) (kW)Cooling 2.5 (0.9~3.1) 3.5 (0.9~4.0) 5.0 (0.9~5.2)

Heating 3.4 (0.9~4.4) 4.2 (0.9~5.0) 6.3 (0.9~7.5)

UK Cooling Capacity (kW)Total 2.2 2.7 4.3

Sensible 2.0 2.4 2.8

EER/COPCooling 4.31 3.57 3.22

Heating 4.30 4.16 3.61

Energy LabelCooling A A A

Heating A A A

Indoor Sound Pressure Level dB(A)Cooling 38/32/26/20 41/35/29/22 48/39/31/25

Heating 39/33/27/23 41/35/30/22 48/39/31/25

Indoor Fan (m3/min)Cooling 8.0/6.2/4.5/3.5 9.7/7.0/5.6/4.6 11.5/9.2/6.8/4.8

Heating 9.5/7.0/5.5/3.3 10.3/8.5/6.6/4.4 13.0/9.6/7.3/4.8

Dimensions (mm) & Weight (kg)

Height 295

Width 795

Depth 198

Weight 10

RAC 25WX8 RAC 35WX8 RAC 50WX8

Outdoor Sound Pressure Level dB(A)Cooling 45 46 50

Heating 46 47 52

Dimensions (mm) & Weight (kg)

Height 548 600

Width 750 792

Depth 288 299

Weight 35 42

Operating Range (ºC)Cooling -10 ~ +43

Heating -15 ~ +21

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)

Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)

Piping (m)

Length 20 30

Lift 10 10

Pre-charged 20 30

Power Supply 230V 1ph 50Hz

Power to Outdoor

Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened

Starting Current (A) 3.9 4.7 8.1

Running Current (230v) (A)Cooling 2.87 4.35 6.83

Heating 3.72 4.49 7.66

Recommended Fuse Size (A) 16 16 16

RAR-3U4

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 13: 2012 A5 Product Catalogue FULL (3)

Outdoor Units

Wall Mounted

For full technical details refer to Technical Manual

RAC Summit

RAS 18FH6 RAS 25FH6 RAS 35FH6 RAS 50FH7 RAS 60YH7 RAS 70YH7 RAS 80YH5A

Nominal Capacity (Min~Max) (kW)

Cooling 2.0(0.9~2.5) 2.5(0.9~3.1) 3.5(0.9~4.0) 5.0(0.9~5.2) 6.05(0.9~6.5) 7.0(0.9~8.0) 8.0(1.5~8.5)

Heating 2.5(0.9~3.2) 3.4(0.9~4.4) 4.2(0.9~5.0) 6.5(0.9~8.1) 7.05(0.9~9.0) 8.2(0.9~9.5) 9.3(1.5~9.7)

UK Cooling Capacity (kW)Total 1.9 2.4 3.3 4.2 5.3 6.47 7.4

Sensible 1.7 2.0 2.5 3.1 4.0 4.8 5.4

EER/COP Cooling 3.64 3.57 3.21 3.20 3.24 3.23 2.61

Heating 4.31 3.86 3.78 3.82 3.62 3.64 3.00

Energy LabelCooling A A A A A A D

Heating A A A A A A D

Indoor Sound Pressure Level (dB(A)

Cooling 35/32/26/20 38/32/26/20 42/35/29/25 47/39/28/24 48/42/33/30 47/42/33/30 46/43/40/36

Heating 36/33/27/23 39/33/27/23 42/35/30/26 47/39/31/27 49/42/34/33 47/42/33/30 47/44/41/39

Indoor Fan (m3/min)

Cooling 7.3/6.7/5.8/5.2 8.5/7.0/6.05.4 10.0/8.0/6.5/5.7 12.0/9.5/6.5/5.5 15.5/11.5/9.0/8.0 17.0/15.5/10.5/8.5 19.0/16.5/13.5/12.1

Heating 8.0/7.0/5.8/5.5 9.5/8.0/7.0/5.8 10.8/8.5/7.5/6.1 12.5/10.0/7.0/6.0 17.5/12.0/8.5/8.0 18.0/14.5/10.5/8.5 19.0/16.5/13.5/12.8

Dimensions (mm) & Weight (kg)

Height 280 295 330

Width 780 1030 1150

Depth 220 207 245

Weight 9.5 12 15 15

RAC 18YH6 RAC 25YH6 RAC 35YH6 RAC 50YH7 RAC 60YH7 RAC 70YH7 RAC 80YH5

Outdoor Sound Pressure Level dB(A)

Cooling 44 46 46 50 50 52 55

Heating 46 48 49 52 53 54 57

Dimensions (mm) & Weight (kg)

Height 550 548 650 800 875

Width 700 750 850 850 925

Depth 258 288 298 298 315

Weight 27 35 45 55 75

Operating Range (ºC)Cooling -10~43

Heating -15~21

Refrigerant Piping (mm) (in)

Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4)

Gas 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 20 30

Lift 10 20

Pre-charged

20 20

Power Supply 230V 1ph 50Hz

Power to Outdoor

Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened 2 Core Screened 4 Core Screened 4 Core Screened 4 Core Screened

Starting Current (A) 3.0 4.5 5.3 7.1 10.0 10.0 14.0

Running Current (230v) (A)Cooling 3.0 3.8 5.2 7.2 8.5 10.0 14.1

Heating 2.9 4.5 5.3 7.6 8.6 10.1 14.3

Recommended Fuse Size (A) 16 16 16 16 16 20 30

RAC-YH6

RAS-YH5A RAS-FH6/7 RAR-3U1/3

RAC-YH7

Page 14: 2012 A5 Product Catalogue FULL (3)

For full technical details refer to Technical Manual

Hitachi Product Catalogue | 15

Utopia ES

Outdoor Units

Wall MountedRPK-FSN2M

RAS-HVRNS2(E)

PC-ART

RPK 2.0FSN2M RPK 2.5FSN2M RPK 3.0FSN2M RPK 4.0FSN2M

Nominal Capacity (Min ~ Max) (kW)Cooling 5.0 (2.0 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2)

Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5)

UK Cooling Capacity (kW)Total 5.2 5.8 7.5 10.6

Sensible 3.7 4.2 5.3 7.5

EER/COPCooling 3.14 2.96 2.82 2.61

Heating 3.21 3.00 3.08 2.81

Energy LabelCooling B C C D

Heating C D D D

Indoor Sound Pressure Level dB(A) 41/39/37 43/40/37 43/40/37 49/46/43

Indoor Fan (m3/min) 14/12/10 17/16/14 17/16/14 22/20/17

Dimensions (mm) & Weight (kg)

Height 295 333

Width 1030 1150

Depth 208 245

Weight 12 18

Recommended Fuse Size (A) 5 5 5 5

Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRNS2 RAS 4.0HVRNS2E

Outdoor 3Ø - - - RAS 4.0HRNS2E

Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 45 (43) 46 (44) 48 (46) 50 (48)

Heating 47 48 50 52

Dimensions (mm) & Weight (kg)

Height 600 800

Width 792 950

Depth 300 370

Weight 1Ø/3Ø 42 / - 44 / - 79 / 79

Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db

Heating (-15 ~ 15)wb (-10 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 9.52 (3/8) 9.52 (3/8)

Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 50 30 50

Lift 30 30 30 30

Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m

Power Supply1 Phase 1Ph 220-240V 50Hz

3 Phase - 3Ph 380-415V 50Hz

Power to Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 6.9 8.8 11.0 14.2

Heating 7.6 10.2 11.3 13.8

Recommended Fuse Size (1Ø/3Ø) (A) 16 / - 20 / - 25 / - 32 / 16

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 15: 2012 A5 Product Catalogue FULL (3)

Outdoor 1Ø RAS 3.0HVRNM2E RAS 4.0HVRNM2E

Outdoor 3Ø - RAS 4.0HRNM2E

Outdoor Sound Pressure Level (Set Back) d(B)A

Cooling 47 (43) 49 (45)

Heating 49 51

Dimensions (mm) & Weight (kg)

Height 800 1380

Width 950 950

Depth 370 370

Weight 1Ø/3Ø 67/- 98/98

Operating Range (ºC)Cooling (-10 ~ 46)db

Heating (-20 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8)

Gas 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 70

Lift 30 30

Pre-charged 30 / 40g/m 30 / 60g/m

Power Supply1 Phase 1Ph 220-240V 50Hz

3 Phase - 3Ph 380-415V 50Hz

Power To Outdoor Outdoor

Interconnection wires No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 10.3 / - 13.5 / 4.8

Heating 11.3 / - 15.6 / 5.5

Recommended Fuse Size (1Ø/3Ø) (A) 20 / - 32 / 16

Outdoor Units

Wall Mounted

Utopia IVX

RPK-FSN2M PC-ART

RAS-HVRNME

RPK 3.0FSN2M RPK 4.0FSN2M

Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2)

Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0)

UK Cooling Capacity (kW)Total 7.5 10.6

Sensible 5.3 7.5

EER/COP Cooling 3.02 3.22

Heating 3.10 3.13

Energy LabelCooling B A

Heating D D

Indoor Sound Pressure Level dB(A) 43/40/37 49/46/43

Indoor Fan m3/min 17/16/14 22/20/17

Dimensions (mm) & Weight (kg)

Height 333

Width 1150

Depth 245

Weight 18

Recommended Fuse Size (A) 5 5

S Y S T E MFREE

Page 16: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 17

Wall Mounted

Outdoor Units

Utopia Centrifugal

RPK 3.0FSN2M

Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.2 ~ 8.0)

Heating 8.0 (3.5 ~ 9.0)

UK Cooling Capacity (kW)Total 7.5

Sensible 5.3

EER/COP Cooling 2.64

Heating 2.62

Energy LabelCooling D

Heating E

Indoor Sound Pressure Level dB(A) 43/40/37

Indoor Fan m3/min 17/16/14

Dimensions (mm) & Weight (kg)

Height 333

Width 1150

Depth 245

Weight 18

Recommended Fuse Size (A) 5

RASC 3.0HVRNE

Outdoor Sound Pressure Level dB(A)Cooling 46

Heating 46

Dimensions (mm) & Weight (kg)

Height 430

Width 1250

Depth 1300

Weight 168

Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44

Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15

Operating Range (ºC)Cooling (-5 ~ 43)db

Heating (-15 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8)

Gas 15.88(5/8)

Piping (m)

Length 30

Lift 30

Pre-charged 20 / 60g/m

Power Supply 1 Phase 1Ph 220-240V 50Hz

Power To Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10

Running Current (A)Cooling 11.3

Heating 11.9

Recommended Fuse Size (A) 32

RASC-HVRNE

RPK-FSN2M PC-ART

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 17: 2012 A5 Product Catalogue FULL (3)

Product Summary

RAC Monozone

600x600 cassetteRAI 25~50NH5A

Utopia ES

600x600RCIM 2.0FSN2

Utopia ES

4-WayRCI 2.0 ~ 6.0FSN3E

2-WayRCD 2.0 ~ 5.0FSN2

Nominal Cooling Capacity (kW) 2.5 ~ 5.0 5.0 5.0 ~ 14.0 5.0 ~ 12.5

Nominal Heating Capacity (kW) 3.5 ~ 6.5 5.6 5.6 ~ 16.0 5.6 ~ 14.0

Refrigerant R410A R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter

Operating Range¹ (Cooling) (db) -10ºC / +43ºC -5ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC

Operating Range (Heating) (wb) -15ºC / +15ºC -15ºC / +15ºC -10ºC / +15ºC (*) -10ºC / +15ºC (*)

Std. Remote Controller Type Infra Red Wired or Infra Red Wired or Infra Red Wired or Infra Red

Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option

Condensate Pump Yes Yes Yes Yes

¹ Selected Models (*) -15ºC 2.0/2.5 models (*) -15ºC 2.0/2.5 models

Features and Benefits

Cassettes

RAC Monozone 600 x 600 Cassette

The 600mm x 600mm ceiling unit neatly fits inside a standard ceiling module which minimises installation work

The user can select between 2-Way, 3-Way or 4-Way operation of auto swing louvres

Utopia 4-Way Cassette

COP 4.55 and EER 3.97

The depth of the units vary from just 248 to 298mm, so they can be installed in a reduced space inside a false ceiling

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Page 18: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 19

Utopia IVX Utopia IVX Centrifugal**

4-WayRCI 3.0 ~ 6.0FSN3E

2-WayRCD 3.0 ~ 5.0FSN2

4-WayRCI 3.0 ~ 5.0FSN3E

2-WayRCD 3.0 ~ 5.0FSN2

7.1 ~ 14.0 7.1 ~ 12.5 7.1 ~ 12.5 7.1 ~ 12.5

8.0 ~ 16.0 8.0 ~ 16.0 8.0 ~ 14.0 8.0 ~ 14.0

R410A R410A R410A R410A

DC-Inverter DC-Inverter DC-Inverter DC-Inverter

-10ºC / +43ºC -10ºC / +43ºC -5ºC / +46ºC -5ºC / +46ºC

-15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC

Wired or Infra Red Wired or Infra Red Wired or Infra Red Wired or Infra Red

24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option

Yes Yes Yes Yes

** 3HP Std. Inverter Centrifugal ** 3HP Std. Inverter Centrifugal

Utopia 2-Way Cassette

The compact turbo fan simplifies the structure and reduces the height of the unit to 298mm. The unit’s low profile design allows easy installation in the most confined spaces inside a ceiling

with built in 7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Page 19: 2012 A5 Product Catalogue FULL (3)

Outdoor Units

600x600 Cassette

For full technical details, refer to Technical Manual

RAC Monozone

RAI 25NH5A RAI 35NH5A RAI 50NH5A

Nominal Capacity (Min ~ Max) (kW)Cooling 2.5(0.9~3.0) 3.5(0.9~4.0) 5.0(0.9~5.2)

Heating 3.5(0.9~5.0) 4.8(0.9~6.6) 6.5(0.9~8.1)

UK Cooling Capacity (kW)Total 2.3 3.2 4.1

Sensible 1.8 2.4 3.0

EER/COPCooling 3.60 3.18 2.51

Heating 3.72 3.53 3.01

Energy LabelCooling A B E

Heating A B D

Indoor Sound Pressure Level (dB(A)Cooling 35/32/29/25 39/34/29/26 43/35/32/29

Heating 36/33/30/27 40/36/32/29 43/36/32/30

Indoor Fan (m3/min)Cooling 8.5/7.0/5.8/5.5 10.8/8.0/5.8/5.5 12.0/8.0/5.8/5.5

Heating 8.5/7.0/5.8/5.5 10.8/8.0/5.8/5.5 12.0/8.0/5.8/5.5

Dimensions (mm) & Weight (kg)(Panel RAI-ECPM)

Height 285

Width 580

Length 580

Panel 32/650/650

Weight 20 (4)

RAI-NH5ARAI-NH5ARAI-NH5A

RAC-NH5 RAR-3U1

RAC 25NH5 RAC 35NH5 RAC 50NH5

Outdoor Sound Pressure Level dB(A)Cooling 46 47 50

Heating 46 49 52

Dimensions (mm) & Weight (kg)

Height 570 650

Width 750 850

Depth 280 298

Weight 38 45

Operating Range (ºC)Cooling -10 ~ +43

Heating -15 ~ +21

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)

Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)

Piping (m)

Length 20

Lift 10

Pre-charged 20

Power Supply AC 1Ph 220~230V 50Hz

Power to Outdoor

Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened

Starting Current (A) 4.2 6.1 10.0

Running Current (230v) (A)Cooling 3.05 4.85 8.74

Heating 4.15 6.00 9.49

Recommended Fuse Size (A) 16 16 16

Page 20: 2012 A5 Product Catalogue FULL (3)

Hitachi Cassettes

2-way, 3-way and 4-way air outlet controlthat can be used in ceiling heights of up to 4.2m

Contact [email protected] to find out more

Hitachi Product Catalogue | 21

Page 21: 2012 A5 Product Catalogue FULL (3)

RAS-HVRN2S RAS-HVRNS2(E)RAS-HVRNM2E

RCIM 2.0FSN2 RCI 2.0FSN3E RCI 2.5FSN3E RCI 3.0FSN3E RCI 4.0FSN3E RCI 5.0FSN3E RCI 6.0FSN3E

Mini 600x600 4-Way 4-Way 4-Way 4-Way 4-Way 4-Way

Nominal Capacity (Min-Max) (kW)

Cooling 5.0 (2.2 ~ 5.6) 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0)

Heating 5.6 (2.2 ~ 7.1) 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0) 16.0 (6.0 ~ 18.0)

UK Cooling Capacity (kW)

Total 5.3 5.3 5.9 7.5 10.6 13.1 15.6

Sensible 3.8 4.1 4.3 5.9 8.3 9.7 11.4

EER/COP Cooling 3.11 3.97 3.28 3.06 3.01 2.91 2.45

Heating 3.31 4.55 3.80 3.29 3.48 3.24 2.88

Energy LabelCooling B A A B B C E

Heating C A A C B C DIndoor Sound Pressure Level dB(A) 42/39/37 32/30/28 32/30/28 34/32/30 38/35/33 39/37/35 42/40/36

Indoor Fan (m³/min) 16/14/12 16/14/12 20/17/15 26/23/20 32/28/24 34/29/25 37/32/27

Dimensions (mm) & Weight (kg)

Height 295 248

Width 570 840

Depth 570 840

Grille 700/700/35 950/950/37

Weight 17 (3.5) 24 (6) 26 (6)Recommended Fuse Size (A) 5 5 5 5 5 5 5

Outdoor 1Ø RAS 2.0HVRN2 RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E

Outdoor 3Ø - - - - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E

Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 45 (43) 45 (43) 46 (44) 48 (46) 50 (48) 52 (50) 55 (53)

Heating 47 47 48 50 52 54 57

Dimensions (mm) & Weight (kg)

Length 600 600 800

Width 792 792 950

Depth 300 300 370

Weight 1Ø/3Ø 42 / - 42 / - 42 / - 44 / - 79 / 79 83 / 83 83 / 83

Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db (-10 ~ 43)db

Heating (-10 ~ 15)wb (-10 ~ 15)wb (-10 ~ 15)wb

Refrigerant Piping (mm) (in)

Liquid 6.35(1/4) 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)

Gas 12.7(1/2) 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 50 50 30 50 50 50

Lift 30 30 30 30 30 30 30

Pre-charged 30 / 30g/m 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m 30 / 60g/m

Power Supply1 phase 1Ph 220-240V

50Hz 1Ph 220-240V 50Hz

3 phase - - - - 3Ph 380-415V 50Hz

Power To Outdoor Outdoor

Interconnection wires No. LNE + 2 Core Screened LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)

Cooling 6.8 5.4 7.8 9.9 15.4 / 5.0 18.4 / 6.5 24.6 / 8.7

Heating 7.2 5.2 7.9 10.4 14.9 / 4.9 18.5 / 6.6 23.8 / 8.4Recommended Fuse Size (1Ø/3Ø) (A) 16 / - 16 / - 20 / - 25 / - 32 / 16 32 / 16 32 / 16

Outdoor Units

Utopia ES

4-Way CassetteRCI-FSN3E PC-ART RCIM-FSN2

S Y S T E MFREE

Page 22: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 23

RCD 2.0FSN2 RCD 2.5FSN2 RCD 3.0FSN2 RCD 4.0FSN2 RCD 5.0FSN2

2-Way 2-Way 2-Way 2-Way 2-Way

Nominal Capacity (Min-Max) (kW)

Cooling 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0)

Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0)

UK Cooling Capacity (kW)

Total 5.3 5.9 7.5 10.6 13.1

Sensible 4.0 4.4 5.6 7.7 9.7

EER/COP Cooling 3.14 2.87 2.81 3.01 3.03

Heating 3.09 3.13 3.08 3.48 3.31

Energy LabelCooling B C C B B

Heating D D D B CIndoor Sound Pressure Level dB(A) 35/32/30 38/34/31 38/34/31 40/36/33 43/40/36

Indoor Fan (m³/min) 15/13/11 19/16/14 19/16/14 29/24/21 34/29/25

Dimensions (mm) & Weight (kg)

Height 298 298

Width 620 620

Depth 860 1420

Grille 1100/710/30 1660/710/30

Weight 27 (6) 30 (6) 30 (6) 48 (8)Recommended Fuse Size (A) 5 5 5 5 5

Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E

Outdoor 3Ø - - - RAS 4.0HRNS2E RAS 5.0HRNS2E

Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 45 (43) 46 (44) 48 (46) 50 (48) 52 (50)

Heating 47 48 50 52 54

Dimensions (mm) & Weight (kg)

Length 600 800

Width 792 950

Depth 300 370

Weight 1Ø/3Ø 42 / - 42 / - 44 / - 79 / 79 83 / 83

Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db

Heating (-10 ~ 15)wb (-10 ~ 15)wb

Refrigerant Piping (mm) (in)

Liquid 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8)

Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 50 30 50 50

Lift 30 30 30 30 30

Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m

Power Supply1 phase 1Ph 220-240V

50Hz

3 phase - - - 3Ph 380-415V 50Hz

Power To Outdoor

Interconnection wires No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)

Cooling 6.7 / - 8.8 / - 10.8 / - 15.4 / 5.4 17.5 / 6.2

Heating 7.7 / - 9.5 / - 11.1 / - 14.9 / 5.3 17.9 / 6.3Recommended Fuse Size (1Ø/3Ø) (A) 16 / - 20 / - 25 / - 32 / 16 32 / 16

Outdoor Units

2-Way CassetteRCD-FSN2 PC-ART

Utopia ES

RAS-HVRN2S RAS-HVRNS2(E)

For full technical details, refer to Technical Manual

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 23: 2012 A5 Product Catalogue FULL (3)

Outdoor Units

Utopia IVX

4-Way / 2-Way CassetteRCI-FSN3ERCD-FSN2 PC-ART

* 3HP Std. Inverter Centrifugal.

RAS-HVRNM2E

RCI 3.0FSN3E RCI 4.0FSN3E RCI 5.0FSN3E RCI 6.0FSN3E RCD 3.0FSN2 RCD 4.0FSN2 RCD 5.0FSN2

4-Way 4-Way 4-Way 4-Way 2-Way 2-Way 2-Way

Nominal Capacity (Min-Max) (kW)

Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0) 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0)

Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0) 16.0 (6.0 ~ 20.0) 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0)

UK Cooling Capacity (kW)

Total 7.5 10.6 13.1 15.6 7.5 10.6 13.1

Sensible 5.9 8.3 9.7 11.4 5.6 7.7 9.7

EER/COP Cooling 3.66 3.90 3.62 3.29 3.05 3.47 3.31

Heating 4.05 4.10 4.06 3.72 3.30 3.41 3.70

Energy LabelCooling A A A A B A A

Heating A A A A C B AIndoor Sound Pressure Level dB(A) 34/32/30 38/35/33 39/37/35 42/40/36 38/34/31 40/36/33 39/37/35

Indoor Fan (m³/min) 26/23/20 32/28/24 34/29/25 37/32/27 19/16/14 29/24/21 34/29/25

Dimensions (mm) & Weight (kg)

Height 840 860 1420

Width 840 620 620

Depth 298 298 298

Grille 950/950/37 1100/710/30 1660/710/30

Weight 26 (6) 30 (6) 48 (8)Recommended Fuse Size (A) 5 5 5 5 5 5 5

Outdoor 1Ø RAS 3.0HVRNM2E

RAS 4.0HVRNM2E

RAS 5.0HVRNM2E

RAS 6.0HVRNM2E

RAS 3.0HVRNM2E

RAS 4.0HVRNM2E

RAS 5.0HVRNM2E

Outdoor 3Ø - RAS 4.0HRNM2E

RAS 5.0HRNM2E

RAS 6.0HRNM2E - RAS

4.0HRNM2ERAS

5.0HRNM2E

Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 47 (43) 49 (45) 51 (47) 51 (48) 47 (43) 49 (45) 51 (47)

Heating 49 51 53 53 49 51 53

Dimensions (mm) & Weight (kg)

Length 800 1380 800 1380

Width 950 950 950 950

Depth 370 370 370 370

Weight 1Ø/3Ø 67 / - 98 / 98 105 / 105 105 / 105 67 / - 98 / 98 105 / 105

Operating Range (ºC)Cooling (-10 ~ 46)db (-10 ~ 46)db

Heating (-20 ~ 15)wb (-20 ~ 15)wb

Refrigerant Piping (mm) (in)

Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)

Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 70 75 75 50 70 75

Lift 30 30 30 30 30 30 30

Pre-charged 30 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 60g/m 30 / 40g/m 30 / 60g/m 30 / 60g/m

Power Supply1 phase 1Ph 220-240V 50Hz 1Ph 220-240V 50Hz

3 phase - 3Ph 380-415V 50Hz - 3Ph 380-415V 50Hz

Power To Outdoor Outdoor

Interconnection wires No. LNE + 2 Core screened LNE + 2 Core screened

Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)

Cooling 8.2 / - 10.9 / 3.9 14.7 / 5.2 18.1 / 6.4 9.9 / - 12.2 / 4.3 15.9 / 5.6

Heating 8.4 / - 11.6 / 4.1 14.7 / 5.2 18.3 / 6.5 10.3 / - 14.0 / 4.9 15.9 / 5.6Recommended Fuse Size (1Ø/3Ø) (A) 25 32 / 16 32 / 16 32 / 16 25 32 / 16 32 / 16

S Y S T E MFREE

Page 24: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 25

RASC-HVRN(M)E

RCI 3.0FSN3E RCD 3.0FSN2 RCI 5.0FSN3E RCD 5.0FSN2

4-Way 2-Way 4-Way 2-Way

Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.4 ~ 8.0) 7.1 (3.4 ~ 8.0) 12.5 (4.7 ~ 14.0) 12.5 (4.7 ~ 14.0)

Heating 8.0 (3.4 ~ 9.0) 8.0 (3.4 ~ 9.0) 14.0 (5.0 ~ 16.0) 14.0 (5.0 ~ 16.0)

UK Cooling Capacity (kW)Total 7.5 7.5 13.1 13.1

Sensible 5.9 5.6 9.7 9.0

EER/COP Cooling 2.90 2.78 2.71 2.69

Heating 3.10 2.69 3.10 3.01

Energy LabelCooling C D D D

Heating D E D D

Indoor Sound Pressure Level dB(A) 34/32/30 38/34/31 39/37/35 43/40/36

Indoor Fan (m3/min) 26/23/20 19/16/14 34/29/25 34/29/25

Dimensions (mm) & Weight (kg)

Height 840 860 840 1420

Width 840 620 840 620

Depth 298 298 298 298

Grille 950/950/38 1100/710/30 950/950/38 1660/710/30

Weight 26 (6) 30 (6) 26 (6) 48 (8)

Recommended Fuse Size (A) 5 5 5 5

RASC 3.0HVRNE* RASC 5.0HVRNME

Outdoor Sound Pressure Level dB(A)Cooling 46 55

Heating 46 56

Dimensions (mm) & Weight (kg)

Height 430 430

Width 1250 1250

Depth 1300 1300

Weight 168 176

Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44 60 / 65/ 69

Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15 100 / 50 / 12

Operating Range (ºC)Cooling (-5 ~ 43)db (-5 ~ 46)db

Heating (-15 ~ 15)wb (-15 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8)

Gas 15.88(5/8) 15.88(5/8)

Piping (m)

Length 30 70

Lift 30 30

Pre-charged 20 / 60g/m 15 / 60g/m

Power Supply 1 Phase 1Ph 220-240V 50Hz 1Ph 220-240V 50Hz

Power To Outdoor Outdoor

Interconnecting Cables No. LNE + 2 Core Screened LNE + 2 Core Screened

Starting Current (A) < 10 < 10

Running Current (230v) (A)Cooling 11.3 22

Heating 11.9 21.6

Recommended Fuse Size (A) 32 40

Utopia IVX Centrifugal

Outdoor Units

4-Way / 2-Way CassetteRCI-FSN3ERCD-FSN2 PC-ART

* 3HP Std. Inverter Centrifugal.For full technical details, refer to Technical Manual

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 25: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

In the Ceiling (ducted)

RAC Monozone In the Ceiling (ducted)

The units are only 750mm long and 235mm in depth

Air intake direction can be horizontal or vertical by interchanging the bottom panel with the fan cover

ready to connect to PCS-6RAD adapter.

Monozone In the Ceiling

Utopia In the Ceiling (ducted)

COP of 4.17 and EER of 3.72

The RPI has a reinforced structure to give the unit more rigidity when it is suspended. It also has one of the lowest heights in the market when it’s installed

The unit has 3 static pressure settings providing greater installation flexibility and can be adapted to suit the installation requirements

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Page 26: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 27

Product Summary MonozoneRAD 25 ~ 35NH7A

Utopia ESRPI 2.0 ~ 10.0FSN3E

Utopia IVXRPI 3.0 ~ 10.0FSN3E

Utopia IVX Centrifugal*RPI 3.0 ~ 10.0FSN3E

Nominal Cooling Capacity (kW) 2.5 ~ 3.5 5.0 ~ 25.0 7.1 ~ 25.0 7.1 ~ 25.0

Nominal Heating Capacity (kW) 3.5 ~ 4.8 5.6 ~ 28.0 8.0 ~ 28.0 8.0 ~ 28.0

Refrigerant R410A R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter

Operating Range1 (Cooling) (db) -10ºC / +43ºC -5ºC / +43ºC -15ºC / +43ºC (*) -5ºC / +46ºC

Operating Range (Heating) (wb) -15ºC / +15ºC -10ºC / +15ºC (*) -20ºC / +15ºC -15ºC / +15ºC

Std. Remote Controller Type Wired Wired or Infra Red Wired or Infra Red Wired or Infra Red

Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option

Condensate Pump Yes Yes# Yes# Yes#

Static Pressure (Pa) Adjustable Adjustable Adjustable Adjustable

Return Air Direction Rear or Bottom Rear or Bottom# Rear or Bottom# Rear or Bottom#

¹ Selected Models(*) -15ºC 2.0/2.5 models

#Option available on 8HP and 10HP(*) -10ºC 3.0~ 6.0 models

#Option available on 8HP and 10HP* 3HP Std. Inverter Centrifugal

#Option available on 8HP and 10HP

Page 27: 2012 A5 Product Catalogue FULL (3)

Outdoor Units

In the Ceiling (ducted)

For full technical details, refer to Technical Manual

RAC Monozone

RAD 25NH7A RAD 35NH7A

Nominal Capacity (Min ~ Max) (kW)Cooling 2.5(0.9~3.0) 3.5(0.9~4.0)

Heating 3.5(0.9~5.0) 4.8(0.9~6.6)

UK Cooling Capacity (kW)Total 2.3 3.2

Sensible 1.8 2.2

EER/COPCooling 3.60 2.82

Heating 3.61 2.82

Energy LabelCooling A C

Heating A D

Indoor Sound Pressure Level dB(A)Cooling 36/34/31/29 36/34/31/29

Heating 37/33/30/27 37/33/30/27

Indoor Fan (m3/min)Cooling 8.2/7.3/6.2/5.5 8.5/7.6/6.2/5.5

Heating 9.2/7.5/6.2/5.5 9.3/7.6/6.2/5.5

Static Pressure (Pa) Standard 30 (low 25, High 35)

Dimensions (mm) & Weight (kg)

Height 235

Width 750

Length 400

Weight 19

RAC 25NH5 RAC 35NH5

Outdoor Sound Pressure Level dB(A)Cooling 46 47

Heating 46 49

Dimensions (mm) & Weight (kg)

Height 570

Width 750

Depth 280

Weight 38

Operating Range (ºC)Cooling -10 ~ +43

Heating -15 ~ +21

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4)

Gas 9.52 (3/8) 9.52 (3/8)

Piping (m)

Length 20

Lift 10

Pre-charged 20

Power Supply 230V 1 ph 50Hz

Power to Outdoor

Interconnecting Cables No. 2 Core Screened 2 Core Screened

Starting Current (A) 4.2 6.1

Running Current (230v) (A)Cooling 3.05 5.45

Heating 4.26 7.47

Recommended Fuse Size (A) 16 16

RAD-NH7A PM RAD 18 NH7

RAC-NH5

Page 28: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

Hitachi Product Catalogue | 29

Utopia ES

In the Ceiling (ducted)PC-ARTRPI-FSN3E

Outdoor Units

RPI 2.0FSN3E RPI 2.5FSN3E RPI 3.0FSN3E RPI 4.0FSN3E RPI 5.0FSN3E RPI 6.0FSN3E RPI 8.0FSN3E RPI 10.0FSN3E

Nominal Capacity (Min-Max) (kW)

Cooling 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (3.4 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0) 20.0 (9.0 ~ 22.4) 25.0 (11.2 ~ 28.0)

Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (3.4 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0) 16.0 (6.0 ~ 18.0) 22.4 (8.3 ~ 25.0) 28.0 (9.0 ~ 31.5)

UK Cooling Capacity (kW)

Total 5.3 5.9 7.5 10.6 13.1 15.6 18.0 22.0

Sensible 4.0 4.5 5.6 7.7 9.4 11.2 12.8 16.0

EER/COP Cooling 3.56 2.89 2.70 2.92 2.93 2.75 2.57 2.41

Heating 3.84 3.62 3.17 3.21 3.33 3.23 3.07 3.03

Energy LabelCooling A C D C C D E E

Heating A A D C C C D DIndoor Sound Pressure Level dB(A) SP-00 33/31/29 35/33/30 35/35/31 37/36/35 39/38/36 40/39/38 54/54/51 55/55/52

Indoor Fan (m³/min) SP-00 16/15/13 19/17/15 22/20/17 30/28/25 35/32/28 36/33/29 66/66/60 75/75/68.5

Static Pressure (Pa) SP-01/00/02 80/50/25 80/50/25 100/60/25 120/80/30 120/80/30 120/80/30 220/220/180 220/220/180

Dimensions (mm) & Weight (kg)

Height 275 275 423

Width 1084 1474 1592

Depth 600 600 600

Weight 35 37 37 49 49 49 85 87

Recommended Fuse Size (A) 5 5 5 5 5 5 10 10

Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E - -

Outdoor 3Ø - - - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E RAS 8.0HRNSE RAS 10.0HRNSE

Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 45 (43) 46 (44) 48 (46) 50 (48) 52 (50) 55 (53) 53 (51) 60 (56)

Heating 47 48 50 52 54 57 55 62

Dimensions (mm) & Weight (kg)

Length 600 800 1380

Width 792 950 950

Depth 300 370 370

Weight 42 / - 42 / - 44 / - 79 / 79 83 / 83 83 / 83 135 141

Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db

Heating (-10 ~ 15)wb (-10 ~ 15)wb

Refrigerant Piping (mm) (in)

Liquid 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)*

Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 28.6(1/8)* 28.6(1/8)*

Piping (m)

Length 50 50 30 50 50 50 50 50

Lift 30 30 30 30 30 30 30 30

Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 65g/m 30 / 120g/m

Power Supply1 Phase 1Ph 220-240V 50Hz - -

3 Phase - - - 3Ph 380-415 50Hz

Power To Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)

Cooling 5.7 / - 8.6 / - 10.4 / - 16.1 / 4.9 17.6 / 6.2 21.1 / 7.5 - / 10.7 - / 14.6

Heating 5.9 / - 8.0 / - 10.5 / - 16.9 / 5.0 17.3 / 6.1 20.5 / 7.3 - / 9.9 - / 13.5

Recommended Fuse Size (A) (1Ø/3Ø) 16 / - 20 / - 20 / - 32 / 16 32 / 16 32 / 16 - / 25 - / 25

RAS-HVRNS2(E)

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 29: 2012 A5 Product Catalogue FULL (3)

* 3HP Std. Inverter Centrifugal

Utopia IVX

Outdoor Units

In the Ceiling (ducted)PC-ARTRPI-FSN3E

RPI 3.0FSN3E RPI 4.0FSN3E RPI 5.0FSN3E RPI 6.0FSN3E RPI 8.0FSN3E RPI 10.0FSN3E

Nominal Capacity (kW)Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0) 20.0 (9.0 ~ 22.4) 25.0 (11.2 ~ 28.0)

Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0) 16.0 (6.0 ~ 20.0) 22.4 (8.3 ~ 25.0) 28.0 (9.0 ~ 31.5)

UK Cooling Capacity (kW)Total 7.5 10.6 13.1 15.6 20.5 25.4

Sensible 5.6 7.7 9.4 11.2 15.8 20.1

EER/COP Cooling 3.55 3.72 3.50 3.16 2.84 2.72

Heating 3.86 4.17 3.76 3.62 3.51 3.34

Energy LabelCooling A A A B C D

Heating A A A A B C

Indoor Sound Pressure Level dB(A) SP-00 35/35/31 37/36/35 39/38/36 40/39/38 54/54/51 55/55/52

Indoor Fan (m3/min) SP-00 22/20/17 30/28/25 35/32/28 36/33/29 66/66/60 75/75/68.5

Static Pressure (Pa) SP-01/00/02 100/60/25 120/80/30 120/80/30 120/80/30 220/220/180 220/220/180

Dimensions (mm) & Weight (kg)

Height 275 275 423

Width 1084 1474 1592

Depth 600 600 600

Weight 37 49 49 49 85 87

Recommended Fuse Size (A) 5 5 5 5 10 10

Outdoor 1Ø RAS 3.0HVRNM2E

RAS 4.0HVRNM2E

RAS 5.0HVRNM2E

RAS 6.0HVRNM2E - -

Outdoor 3Ø - RAS 4.0HRNM2E

RAS 5.0HRNM2E

RAS 6.0HRNM2E

RAS 8.0HRNME

RAS 10.0HRNME

Outdoor Sound Pressure Level dB(A)

Cooling 47 (43) 49 (45) 51 (47) 51 (48) 52 (50) 55 (53)

Heating 49 51 53 53 54 57

Dimensions (mm) & Weight (kg)

Height 800 1380 1650

Width 950 950 1100

Depth 370 370 390

Weight 1Ø/3Ø 67 / - 98 / 98 105 / 105 105 / 105 - / 170 - / 170

Operating Range (ºC)Cooling (-10 ~ 46)db (-15 ~46)db

Heating (-20 ~ 15)wb (-20 ~15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)* 12.70(1/2)*

Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 28.6(1/8)* 28.6(1/8)*

Piping (m)

Length 50 70 75 75 100 100

Lift 30 30 30 30 30 30

Pre-charged 30 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 60g/m Calculate Calculate

Power Supply1 Phase 1Ph 220-240V 50Hz -

3 Phase - 3Ph 380-415V 50Hz

Power to Outdoor

Interconnecting Cables No. LNE + 2 Core screened

Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 8.2 10.9 / 3.9 15.0 / 5.3 18.1 / 6.4 9.2 12.0

Heating 8.0 / - 10.7 / 3.8 14.5 / 5.1 18.2 / 6.4 - / 9.2 - / 12.3

Recommended Fuse Size (A) (1Ø/3Ø) 8.3 / - 10.7 / 3.8 15.2 / 5.4 18.1 / 6.4 - / 8.2 - / 11.1

RAS-HRNM(2)E

S Y S T E MFREE

Page 30: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 31

RASC-HVRNE

Utopia IVX Centrifugal

Outdoor Units

In the Ceiling (ducted)

RPI 3.0FSN3E RPI 5.0FSN3E RPI 10.0FSN3E

Nominal Capacity (kW)Cooling 7.1 (3.4 ~ 8.0) 12.5 (4.7 ~ 14.0) 23.0 (10.3 ~ 25.0)

Heating 8.0 (3.4 ~ 9.0) 14.0 (5.0 ~ 16.0) 25.0 (9.4 ~ 26.0)

UK Cooling Capacity (kW)Total 7.4 12.6 22.0

Sensible 5.2 9.1 17.4

EER/COP Cooling 2.73 2.61 2.41

Heating 2.68 2.97 2.64

Energy LabelCooling D D E

Heating E D E

Indoor Sound Pressure Level dB(A) SP-00 35/35/31 39/38/36 55/55/52

Indoor Fan (m3/min) SP-00 22/20/17 35/32/28 75/75/68.5

Static Pressure (Pa) SP-01/00/02 100/60/25 120/80/30 220/220/180

Dimensions (mm) & Weight (kg)

Height 275 275 423

Width 1084 1474 1592

Depth 600 600 600

Weight 37 49 87

Recommended Fuse Size (A) 5 5 10

Outdoor 1Ø RASC 3.0HVRNE* RASC 5.0HVRNME -

Outdoor 3Ø - - RASC 10.0HRNME

Outdoor Sound Pressure Level dB(A)Cooling 46 55 68

Heating 46 56 68

Dimensions (mm) & Weight (kg)

Height 430 640

Width 1250 1850

Depth 1300 985

Weight 168 176 262

Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44 60 / 65/ 69 90 / 105 / 109

Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15 100 / 50 / 12 130 / 62 / 25

Operating Range (ºC)Cooling (-5 ~ 43)db (-5 ~ 46)db

Heating (-15 ~ 15)wb (-15 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 12.7 (1/2)

Gas 15.88(5/8) 15.88(5/8) 28.6(1/8)*

Piping (m)

Length 30 70 50

Lift 30 30 30

Pre-charged 20 / 60g/m 15 / 60g/m 7.5 / 120g/m

Power Supply1 Phase 1Ph 220-240V 50Hz -

3 Phase - 3Ph 380-415V 50Hz

Power to Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 11.3 / - 22 / - - / 20.1

Heating 11.9 / - 21.6 / - - / 20.2

Recommended Fuse Size (A) (1Ø/3Ø) 32 / - 40 / - - / 40

* 3HP Std. Inverter Centrifugal.

PC-ART RPI-FSN3E

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 31: 2012 A5 Product Catalogue FULL (3)

Ceiling Suspended

Features and Benefits

Utopia Ceiling Suspended

COP of 3.62 and EER of 3.32

An innovative fan and heat exchanger design led to the creation of today’s ultra slim ceiling unit. Fully adjustable mounting brackets allow the unit to be fitted flush with the ceiling

To expand the installation and positioning options the unit has a choice of two drain pipe connections, also refrigeration pipes can be connected to the left, right or rear of the unit

A highly efficient, multi blade centrifugal fan along with the automatic swing louvre generates a powerful and evenly distributed airflow ensuring comfort throughout the room

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Page 32: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 33

Product Summary Utopia ESRPC 2.0 ~ 6.0FSN2E

Utopia IVXRPC 3.0 ~ 6.0FSN2E

Utopia IVX Centrifugal*RPC 3.0 ~ 5.0FSN2E

Nominal Cooling Capacity (kW) 5.0 ~ 14.0 7.1 ~ 14.0 7.1 ~ 12.5

Nominal Heating Capacity (kW) 5.6 ~ 16.0 8.0 ~ 16.0 8.0 ~ 14.0

Refrigerant R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter

Operating Range1 (Cooling) (db) -10ºC / +43ºC -10ºC / +43ºC -5ºC / +46ºC

Operating Range (Heating) (wb) -10ºC / +15ºC (*) -15ºC / +15ºC -15ºC / +15ºC

Std. Remote Controller Type Wired or Infra Red Wired or Infra Red Wired or Infra Red

Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option

Condensate Pump No No No

¹ Selected Models (*) -15ºC 2.0/2.5 models * 3HP Std. Inverter Centrifugal

Page 33: 2012 A5 Product Catalogue FULL (3)

Outdoor UnitsRAS-H(V)RNM2E

Utopia ES

Outdoor 1Ø RAS 2.0HVRN2 RAS 2.5HVRN2 RAS 3.0HVRN2S RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E

Outdoor 3Ø - - - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E

Outdoor Sound Pressure Level dB(A)

Cooling 45 (43) 46 (44) 48 (46) 50 (48) 52 (50) 55 (53)

Heating 47 48 50 52 54 57

Dimensions (mm) & Weight (kg)

Height 600 800

Width 792 950

Depth 300 370

Weight 1Ø/3Ø 42 / - 42 / - 44 / - 79 / 79 83 / 83 83 / 83

Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db

Heating (-10 ~ 15)wb (-10 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)

Gas 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 50 30 50 50 50

Lift 30 30 30 30 30 30

Pre-charged 30 / 30g/m 30 / 30g/m 20 / 30g/m 20 / 40g/m 30 / 60g/m 30 / 60g/m

Power Supply1 Phase 1Ph 220-240V 50Hz

3 Phase - - - 3Ph 380-415 50Hz

Power to Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 7.5 / - 9.9 / - 10.4 / - 16.1 / 5.7 18.8 / 6.6 24.8 / 8.8

Heating 8.5 / - 10.8 / - 10.5 / - 16.9 / 6.0 19.1 / 6.7 24.1 / 8.5

Recommended Fuse Size (A) (1Ø/3Ø) 16 / - 20 / - 20 / - 32 / 16 32 / 16 32 / 16

RPC 2.0FSN2E

RPC 2.5FSN2E RPC 3.0FSN2E RPC 4.0FSN2E RPC 5.0FSN2E RPC 6.0FSN2E

Nominal Capacity (Min-Max) (kW)

Cooling 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 7.1 (1.5 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0)

Heating 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 8.0 (1.5 ~ 9.0) 11.2 (5.0 ~ 12.5) 14.0 (6.0 ~ 16.0) 16.0 (6.0 ~ 18.0)

UK Cooling Capacity (kW)Total 5.3 5.9 7.5 10.6 13.1 15.6

Sensible 4.0 4.5 5.6 7.7 9.4 11.2

EER/COP Cooling 2.73 2.55 2.82 2.62 2.80 2.41

Heating 2.73 2.73 3.16 2.81 3.09 2.83

Energy LabelCooling D E C D D E

Heating E E D D D D

Indoor Sound Pressure Level dB(A) 44/42/38 46/43/41 48/45/42 49/45/39 49/46/41 50/48/44

Indoor Fan (m3/min) 15/13/10 18/16/12 21/17/15 30/24/19 35/28/21 37/32/27

Dimensions (mm) & Weight (kg)

Length 1094 1314 1314 1574

Width 625 625 625 625

Depth 163 163 225 225

Weight 28 31 31 35 41 41

Recommended Fuse Size (A) 5 5 5 5 5 5

Ceiling SuspendedRPC-FSN2E PC-ART

S Y S T E MFREE

Page 34: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 35

Utopia IVX

RPC-FSN2E PC-ART

Ceiling Suspended

Outdoor UnitsRAS-HVRNS2(E)

RPC 3.0FSN2E RPC 4.0FSN2E RPC 5.0FSN2E RPC 6.0FSN2E

Nominal Capacity (Min-Max) (kW)Cooling 7.1 (3.2 ~ 8.0) 10.0 (4.9 ~ 11.2) 12.5 (5.7 ~ 14.0) 14.0 (6.0 ~ 16.0)

Heating 8.0 (3.5 ~ 10.6) 11.2 (5.0 ~ 14.0) 14.0 (6.0 ~ 18.0) 16.0 (6.0 ~ 20.0)

UK Cooling Capacity (kW)Total 7.8 10.5 13.1 15.7

Sensible 5.4 7.5 9.2 11.0

EER/COP Cooling 3.07 3.32 3.24 2.79

Heating 3.25 3.28 3.62 3.34

Energy LabelCooling B A A D

Heating C C A C

Indoor Sound Pressure Level dB(A) 48/45/42 49/45/39 49/46/41 50/48/44

Indoor Fan (m3/min) 21/17/15 30/24/19 35/28/21 37/32/27

Dimensions (mm) & Weight (kg)

Length 1314 1314 1574

Width 625 625 625

Depth 163 225 225

Weight 31 35 41 41

Recommended Fuse Size (A) 5 5 5 5

Outdoor 1Ø RAS 3.0HVRNM2E RAS 4.0HVRNM2E RAS 5.0HVRNM2E RAS 6.0HVRNM2E

Outdoor 3Ø - RAS 4.0HRNM2E RAS 5.0HRNM2E RAS 6.0HRNM2E

Outdoor Sound Pressure Level dB(A)Cooling 47 (43) 49 (45) 51 (47) 51 (48)

Heating 49 51 53 53

Dimensions (mm) & Weight (kg)

Height 800 1380

Width 950 950

Depth 370 370

Weight 1Ø/3Ø 67 / - 98 / 98 105 / 105 105 / 105

Operating Range (ºC)Cooling (-10 ~ 46)db

Heating (-20 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)

Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)

Piping (m)

Length 50 70 75 75

Lift 30 30 30 30

Pre-charged 30 / 40g/m 30 / 60g/m 30 / 60g/m 30 / 60g/m

Power Supply1 Phase 1Ph 220-240V 50Hz

3 Phase - 3Ph 380-415V 50Hz

Power to Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10 < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 9.5 / - 12.6 / 4.4 16.1 / 5.1 21.2 / 7.5

Heating 10.2 / - 14.4 / 5.1 16.1 / 5.4 20.2 / 7.2

Recommended Fuse Size (A) (1Ø/3Ø) 20 / - 32 / 16 32 / 16 32 / 16

S Y S T E MFREE

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 35: 2012 A5 Product Catalogue FULL (3)

Utopia IVX Centrifugal

Outdoor Units

Ceiling SuspendedRPC-FSN2E PC-ART

RPC 3.0FSN2E RPC 5.0FSN2E

Nominal Capacity (Min-Max) (kW)Cooling 7.1 (1.5 ~ 8.0) 12.5 (4.7 ~ 14.0)

Heating 8.0 (1.5 ~ 9.0) 14.0 (5.0 ~ 16.0)

UK Cooling Capacity (kW)Total 7.6 13.1

Sensible 5.5 9.4

EER/COP Cooling 2.70 2.63

Heating 2.62 2.98

Energy LabelCooling D D

Heating E D

Indoor Sound Pressure Level dB(A) 48/45/42 49/46/41

Indoor Fan (m3/min) 21/17/15 35/28/21

Dimensions (mm) & Weight (kg)

Length 1314 1574

Width 625 625

Depth 163 225

Weight 31 41

Recommended Fuse Size (A) 5 5

RASC-HVRN(M)E

RASC 3.0HVRNE* RASC 5.0HVRNME

Outdoor Sound Pressure Level dB(A)

Cooling 46 55

Heating 46 56

Dimensions (mm) & Weight (kg)

Height 430

Width 1250

Depth 1300

Weight 168 176

Outdoor Fan (Min-Nom-Max) (m³/min) 34 / 40 / 44 60 / 65/ 69

Static Pressure (Min-Nom-Max) (Pa) 100 / 50 / 15 100 / 50 / 12

Operating Range (ºC)Cooling (-5 ~ 46)db

Heating (-15 ~ 15)wb (-15 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8)

Gas 15.88(5/8) 15.88(5/8)

Piping (m)

Length 30 70

Lift 30 30

Pre-charged 20 / 60g/m 15 / 60g/m

Power Supply 1 Phase 1Ph 220-240V 50Hz

Power To Outdoor

Interconnecting Cables No. LNE + 2 Core Screened

Starting Current (A) < 10 < 10

Running Current (230v) (A)Cooling 11.3 22

Heating 11.9 21.6

Recommended Fuse Size (A) 32 40

* 3HP Std. Inverter Centrifugal

S Y S T E MFREE

Page 36: 2012 A5 Product Catalogue FULL (3)

Hitachi Utopia IVX Centrifugal

Can be installed inside where circumstances or planning regulations restrict the use of traditional-style outdoor units

Contact [email protected] find out more

Hitachi Price List | 37

Page 37: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Floor Mounted

All RAC Floor Mounted

ambient temperature

Optional simplified hard wired or infra red remote controller with 7 day timer

Compatible with H-LINK II Control and CS Net Web controls that integrate with all leading BMS protocols.

RAC Shirokuma Floor Mounted

Units are available in a variety of colours to compliment any interior

The unit comes with a removable stand which gives the option of mounting it on the wall.

RAC NX2 Floor Mounted

Utopia Floor Mounted

The space saving design (620mm in height, 220mm in depth), fits perfectly into the space below bay windows and allows the unit to be freely installed without spoiling the aesthetics of a room

It is also possible to conceal the remote controller as there is space to install a PC-ART inside the casing

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Page 38: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 39

Product Summary

Shirokuma NX2 Standard Utopia ES

RAF 25 ~ 50FX8 RAF 25 ~ 50NX2 Floor Mounted uncasedRPFI 2.0 ~ 2.5FSN2E

Floor Mounted casedRPF 2.0 ~ 2.5FSN2E

Nominal Cooling Capacity (kW) 2.5 ~ 5.0 2.5 ~ 5.0 5.0 ~ 6.3 5.0 ~ 6.3

Nominal Heating Capacity (kW) 3.4 ~ 6.5 3.4 ~ 6.0 5.6 ~ 7.0 5.6 ~ 7.0

Refrigerant R410A R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter

Operating Range1 (Cooling) (db) -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC -10ºC / +43ºC

Operating Range (Heating) (wb) -15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC -15ºC / +15ºC

Std. Remote Controller Type Infra Red Infra Red Wired or Infra Red Wired or Infra Red

Remote Control Timer 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option 24hr or 7 Day Option

Condensate Pump No No No No

¹ Selected Models

Page 39: 2012 A5 Product Catalogue FULL (3)

Outdoor Units

Floor Mounted

RAC Shirokuma

RAF 25FX8 (W/B) RAF 35FX8 (W/B) RAF 50FX8 (W/B)

Nominal Capacity (Min ~ Max) (kW)Cooling 2.5 (0.9~3.1) 3.5 (0.9~4.0) 5.0 (0.9~5.2)

Heating 3.4 (0.9~4.4) 4.2 (0.9~5.0) 6.5 (0.9~8.1)

UK Cooling Capacity (kW)Total 2.4 3.1 4.2

Sensible 1.9 2.5 3.1

EER/COPCooling 4.31 3.43 3.21

Heating 4.30 3.69 3.65

Energy LabelCooling A A A

Heating A A A

Indoor Sound Pressure Level dB(A)Cooling 38/31/26/20 39/31/26/20 43/36/29/22

Heating 38/31/27/23 39/31/26/20 44/36/29/22

Indoor Fan (m3/min)Cooling 10.5/8.5/6.5/4.5 10.5/8.5/6.5/4.5 11.5/9.0/7.5/5.0

Heating 11.0/9.0/7.0/5.0 11.0/9.0/7.0/5.0 12.0/9.5/8.0/5.5

Dimensions (mm) & Weight (kg)

Height 590

Width 750

Depth 215

Weight 15

RAC 25FX8 RAC 35FX8 RAC 50FX8

Outdoor Sound Pressure Level dB(A)Cooling 45 46 50

Heating 47 48 52

Dimensions (mm) & Weight (kg)

Height 548 600

Width 750 792

Depth 288 299

Weight 35 42

Operating Range (ºC)Cooling -10 ~ +43

Heating -15 ~ +21

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)

Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)

Piping (m)

Length 20 30

Lift 10 10

Pre-charged 20 30

Power Supply 230V 1ph 50Hz

Power to Outdoor

Interconnecting Cables No. 2 Core Screened 2 Core Screened 2 Core Screened

Starting Current (A) 4.0 5.8 8.2

Running Current (230v) (A)Cooling 2.97 4.67 6.85

Heating 3.82 5.58 7.82

Recommended Fuse Size (A) 16 16 16

RAF-FX8 RAR-3U2

RAC-FX8

Page 40: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 41

RAC NX2

Outdoor Units

Floor Mounted

For RAC accessories see page 49

RAF 25NX2 RAF 35NX2 RAF 50NX2

Nominal Capacity (Min ~ Max) (kW)Cooling 2.5 (0.9-3.1) 3.5 (0.9-4.0) 5.0 (0.9-5.2)

Heating 3.4 (0.9-4.4) 4.2 (0.9-5.0) 6.0 (0.9-7.3)

UK Cooling Capacity (kW)Total 2.1 2.9 4.2

Sensible 1.9 2.5 3.2

EER/COPCooling 3.57 3.21 3.21

Heating 3.86 3.78 3.61

Energy LabelCooling A A A

Heating A A A

Indoor Sound Pressure Level dB(A)Cooling 38/32/26/20 40/32/27/22 44/37/29/26

Heating 38/32/26/20 39/32/26/23 44/37/29/25

Indoor Fan (m3/min)Cooling 9.0/7.7/6.3/5.0 10.0/8.3/6.8/5.5 10.8/8.8/7.2/6.2

Heating 10.0/8.3/6.8/5.3 10.8/9.0/7.3/5.8 12.0/9.5/7.8/6.7

Dimensions (mm) & Weight (kg)

Height 600

Width 760

Depth 235

Weight 14

RAC 25NX2 RAC 35NX2 RAC 50NX2

Outdoor Sound Pressure Level dB(A)Cooling 46 47 52

Heating 48 49 52

Dimensions (mm) & Weight (kg)

Height 505 548 600

Width 700 750 792

Depth 258 288 299

Weight 27 35 40

Operating Range (ºC)Cooling -10 ~ +43

Heating -15 ~ +21

Refrigerant Piping (mm) (in)Liquid 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)

Gas 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)

Piping (m)

Length 20

Lift 10

Pre-charged 20

Power Supply 230V 1ph 50Hz

Power to Outdoor

Interconnecting Cables No. 2 Core Screened

Starting Current (A) 4.0 5.8 8.2

Running Current (230v) (A)Cooling 2.97 4.67 6.85

Heating 3.82 5.58 7.82

Recommended Fuse Size (A) 16 16 16

RAF-NX2

RAC-NX2

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 41: 2012 A5 Product Catalogue FULL (3)

RPFI-FSN2ERPF-FSN2E PC-ART

RAS-HVRN2

Floor Uncased and Floor CasedRPFI 2.0FSN2E

UncasedRPF 2.0FSN2E

CasedRPFI 2.5FSN2E

UncasedRPF 2.5FSN2E

Cased

Nominal Capacity (Min ~ Max) (kW)Cooling 5.0 (2.2 ~ 5.6) 5.0 (2.2 ~ 5.6) 6.0 (2.2 ~ 6.3) 6.0 (2.2 ~ 6.3)

Heating 5.6 (2.2 ~ 7.1) 5.6 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1) 7.0 (2.2 ~ 7.1)

UK Cooling Capacity (kW)Total 5.3 5.3 5.9 5.9

Sensible 3.9 3.9 4.3 4.3

EER/COPCooling 3.11 3.11 2.64 2.64

Heating 3.18 3.18 2.84 2.84

Energy LabelCooling B B D D

Heating D D D D

Sound Pressure Level dB(A) 39/36/32 32/36/39 42/38/34 34/38/42

Indoor Fan (m3/min) 16/14/11 11/14/16 16/14/11 11/14/16

Dimensions (mm) & Weight (kg)

Length 620 630 620 630

Width 1223 1420 1223 1420

Depth 220 220 220 220

Weight 27 33 28 34

Recommended Fuse Size (A) 5 5 5 5

RAS 2.0HVRN2 RAS 2.5HVRN2

Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 45 (43) 46 (44)

Heating 47 48

Dimensions (mm) & Weight (kg)

Height 600 600

Width 792 792

Depth 300 300

Weight 42 42

Operating Range (ºC)Cooling (-10 ~ 43)db (-10 ~ 43)db

Heating (-10 ~ 15)wb (-10 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 6.35(1/4) 6.35(1/4)

Gas 12.7(1/2) 12.7(1/2)

Piping (m)

Length 50 50

Lift 30 30

Pre-charged 30 / 30g/m 30 / 30g/m

Power Supply 1Ph 220-240V 50Hz 1Ph 220-240V 50Hz

Power to Outdoor Outdoor

Interconnecting Cables No. LNE + 2 Core Screened LNE + 2 Core Screened

Starting Current (A) < 10 < 10

Running current (A)Cooling 6.7 9.7

Heating 7.4 10.5

Recommended Fuse Size (A) 16 20

Utopia ES

Outdoor Units

Floor Mounted

S Y S T E MFREE

Page 42: 2012 A5 Product Catalogue FULL (3)

Hitachi NX2

With A/A energy rating and capacities from 2.5kW to 6.0kW, the NX2 floor mount can be installed with RAC Multizone

product ranges for total comfort

Contact [email protected] to find out more

Hitachi Product Catalogue | 43

Page 43: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Multizone Multi Split systems

The Hitachi Multizone range was the world’s

first all-DC Inverter Multisplit system with zone

by zone cooling or heating for up to six rooms.

Hitachi DC scroll and DC twin-rotary compressor,

together with award-winning DC inverter PAM

technology, aid the achievement of a system

power factor of almost 100%, thus providing

unparalleled performance and efficiency.

RAC Multizone

COP of 4.34 and EER of 4.47

A washable carbon and anti-bacteria air purifying filter ensures that the micro dust, pollen particles and odours that can collect on filters can be easily removed

Compatibility between product ranges of outdoor and indoor units

The wide range of units have been designed for cooling operation under low temperatures, down to -10°C. This feature enables cooling to be obtained even in winter on buildings with high internal heat gains due to lighting, people and machines, particularly in areas such as shops and lecture rooms. The heating operation under low temperature, down to -15°C can also be performed

Infra red remote controller with 24hr timer, simplified hard wired controller or hard wired remote controller with built in 7 day timer

Compatible with H-LINK Control/Ready to Connect to PCS-6RAD Adapter.

Page 44: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 45

Product Summary RAM 35QH52 Rooms

RAM 52QH52 Rooms

RAM 53QH53 Rooms

RAM 71QH54 Rooms

RAM 90QH55 Rooms

RAM 130QH56 Rooms

Nominal Cooling Capacity (kW) 3.5 (1.5-4.0)

5.2 (1.5-6.6)

5.2 (1.5-6.6)

7.1 (2.4-8.8)

9.0 (1.5-9.5)

12.6 (1.5-13.2)

Nominal Heating Capacity (kW) 4.2 (1.5-5.0)

6.8 (1.5-7.2)

6.8 (1.5-7.2)

8.6 (2.6-9.5)

11.0 (1.5-11.5)

14.4 (1.5-14.4)

Refrigerant R410A R410A R410A R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter DC-Inverter

Operating Range (Cooling) (db) -10ºC / +43ºC

Operating Range (Heating) (wb) -15ºC / +21ºC

Remote Controller Type Hard Wired or Infra Red

Remote Control Timer 24hr or 7 Day option

Page 45: 2012 A5 Product Catalogue FULL (3)

Outdoor Units

For full technical details, refer to Technical Manual

RAM 35QH5 RAM 52QH5 RAM 53QH5 RAM 71QH5 RAM 90QH5 RAM 130QH5

Nominal Capacity (Min-Max) (kW) Cooling 3.5 (1.5 - 4.0) 5.2 (1.5 - 6.6) 5.2 (1.5 - 6.6) 7.1 (2.4 - 8.8) 9.0 (1.5 - 9.5) 12.6 (1.50 - 13.20)Heating 4.2 (1.5 - 5.0) 6.8 (1.5 - 7.2) 6.8 (1.5 - 7.2) 8.6 (2.8 - 9.5) 11.0 (1.5 - 11.5) 14.4 (1.50 - 14.40)

EER/COP Cooling 3.72 3.47 3.41 3.32 3.81 3.01Heating 4.94 3.79 4.03 4.03 4.47 3.79

Energy LabelCooling A A A A A BHeating A A A A A A

Maximum Indoor Units 2 2 3 4 5 1, 2, 3 4, 5, 6Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 49(43) 52(45) 52(45) 53(43) 55(46) 55(48)Heating 51(44) 53(45) 53(45) 56(43) 58(52) 56(48)

Dimensions (mm) & Weight (kg)

Height 570 650 650 800 800 1450Width 750 850 850 850 950 855Depth 280 298 298 298 370 308Weight 40 50 50 55 71 113

Operating Range (ºC)Cooling -10ºC / 43ºC (db)Heating -15ºC / 21ºC (wb)

Power Supply AC 1Ph 220-230V 50HzPower To OutdoorInterconnecting Cables No. / Indoors 2 Core ScreenedStarting Current (A) 5.8 11 11 14.5 16 20

Running Current (230v) (A)Cooling 5.7 6.6 6.7 9.4 10.8 19.2Heating 6.2 7.9 7.4 9.6 11.3 17.4

Recommended Fuse Size (A) 16 16 16 30 30 30

At least two indoor units should be connected (RAM-90QH5)At least four indoor units should be connected (RAM-130QH5)

RAM-QH5

RAC Multi Split Systems

Page 46: 2012 A5 Product Catalogue FULL (3)

Indoor Units

Hitachi Product Catalogue | 47

RAC Multi Split Systems

For full technical details, refer to Technical Manual

RAK-QH8(S)

Indoor Unit RAK 18QH8S (W/B)* RAK 25QH8 (W/B) RAK 35QH8 (W/B) RAK 50QH8 (W/B)

Nominal Cooling (kW) 2.0 2.5 3.5 5.0

Nominal Heating (kW) 2.5 3.6 4.5 6.7

Indoor Unit RAI - 25NH5A RAI - 35NH5A RAI - 50NH5A

Nominal Cooling (kW) 2.5 3.5 5.0

Nominal Heating (kW) 3.6 4.5 6.7

RAF-QH8

Indoor Unit RAF 25QH8 (W/B) RAF 35QH8 (W/B) RAF 50QH8 (W/B)

Nominal Cooling (kW) 2.5 3.5 5.0

Nominal Heating (kW) 3.6 4.5 6.7

Indoor Unit RAF - 25NX2 RAF - 35NX2 RAF - 50NX2

Nominal Cooling (kW) 2.5 3.5 5.0

Nominal Heating (kW) 3.6 4.5 6.7

* RAK 18QHS8 can be DIP switched to size 12

RAI-NH5ARAI

RAD-NH7A

Indoor Unit RAD - 18NH7A RAD - 25NH7A RAD - 35NH7A RAD - 50NH7A

Nominal Cooling (kW) 2.0 2.5 3.5 5.0

Nominal Heating (kW) 2.5 3.6 4.5 6.7

RAF-NX2

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 47: 2012 A5 Product Catalogue FULL (3)

Combinations

For full technical details, refer to Technical ManualFurther Control options available see page 86

RAM 35QH52 Indoor UnitsNo.1 No.212 12 ~ 3518 18 ~ 3525 25 ~ 35

RAM 52QH52 Indoor UnitsNo.1 No.212 12 ~ 5018 18 ~ 5025 25 ~ 5035 35 ~ 50

RAM 53QH52 Indoor Units 3 Indoor UnitsNo.1 No.2 No.1 No.2 No.312 12 ~ 50 12 12 12 ~ 5018 18 ~ 50 12 18 18 ~ 5025 25 ~ 50 12 25 25 ~ 3535 35 ~ 50 12 35 35

18 18 18 ~ 5018 25 25 ~ 3518 35 3525 25 25 ~ 35

RAM 71QH52 Indoor Units 3 Indoor Units 4 Indoor UnitsNo.1 No.2 No.1 No.2 No.3 No.1 No.2 No.3 No.4

12 12 ~ 50 12 12 12 ~ 50 12 12 12 12 ~ 5018 18 ~ 50 12 18 18 ~ 50 12 12 18 18 ~ 5025 25 ~ 50 12 25 25 ~ 50 12 12 25 25 ~ 5035 35 ~ 50 12 35 35 ~ 50 12 12 35 35 ~ 5050 50 12 50 50 12 18 18 18 ~ 50

18 18 18 ~ 50 12 18 25 25 ~ 5018 25 25 ~ 50 12 18 35 3518 35 35 ~ 50 12 25 25 25 ~ 3525 25 25 ~ 50 12 25 35 3525 35 35 ~ 50 18 18 18 18 ~ 5035 35 35 18 18 25 25 ~ 35

18 18 35 3518 25 25 25 ~ 3525 25 25 25 ~ 35

Minimum of 2 indoor units must be connected.Single unit operation possible.

RAM 90QH52 Indoor Units 3 Indoor Units 4 Indoor Units 5 Indoor UnitsNo.1 No.2 No.1 No.2 No.3 No.1 No.2 No.3 No.4 No.1 No.2 No.3 No.4 No.518 18~50 18 18 18~50 18 18 18 18~50 18 18 18 18 18~5025 25~50 18 25 25~50 18 18 25 25~50 18 18 18 25 25~5035 35~50 18 35 35~50 18 18 35 35~50 18 18 18 35 35~5050 50 18 50 50 18 18 50 50 18 18 18 50 50

25 25 25~50 18 25 25 25~50 18 18 25 25 25~5025 35 35~50 18 25 35 35~50 18 18 25 35 35~5025 50 50 18 25 50 50 18 18 35 35 3535 35 35~50 18 35 35 35~50 18 25 25 25 25~5035 50 50 18 35 50 50 18 25 25 35 35~5050 50 50 25 25 25 25~50 18 25 35 35 35

25 25 35 35~50 25 25 25 25 25~5025 25 50 50 25 25 25 35 3525 35 35 35~50 25 25 35 35 3535 35 35 35~50 - - - - -

RAC Multi Split Systems

Page 48: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 49

Combinations

Model Code

SPX-RCK3 Wired Remote Controller - WX8, FH6, FH7, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8

SPX-RCK2 Wireless Remote Controller & Receiver Kit - RAD-NH7A

SPX-WKT1 Wired Remote Controller + 7 Day Timer - WX8, FH6, FH7, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8

SPX-DST1 Optional Distributor Kit for SPK-WKT1

SPX-WDST8M Optional wiring kit for SPX-WKT1 & SPX-DST1

PSC-6RAD H-LINK Adapter - WX8, FH6, FH7, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8

RAC Accessories

ModelL TOTAL L MIN L MAX H MAX H INDOOR Piping Pre-charged

(m) (m) (m) (m) (m) Liq. (mm) (in) Gas (mm) (in) (m) / (g/m)RAM 35QH5 35 5 25 20 5 6.35(1/4) x 2 9.52(3/8) x 2 35 / -RAM 52QH5 35 5 25 20 5 6.35(1/4) x 2 9.52(3/8) x 2 35 / -RAM 53QH5 45 5 25 20 5 6.35(1/4) x 3 9.52(3/8) x 3 35 / 20g/mRAM 71QH5 60 5 25 20 5 6.35(1/4) x 4 9.52(3/8) x 4 30 / 20g/mRAM 90QH5 75 5 25 20 5 6.35(1/4) x 5 9.52(3/8) x 5 30 / 15g/m

RAM 130QH5

L145 5

2520 5 6.35(1/4) x 3 9.52(3/8) x 3 35 / 20g/mL2 L2 + L3 <35L3

L445 5

2520 5 6.35(1/4) x 3 9.52(3/8) x 3 35 / 20g/mL5 L5 + L6 <35L6

MIN MAX

MAX INDOOR

RAM 130QH54 Indoor Units 5 Indoor Units 6 Indoor Units

Circuit 1 Circuit 2 Circuit 1 Circuit 2 Circuit 1 Circuit 2No.1 No.2 No.3 No.4 No.1 No.2 No.3 No.4 No.5 No.1 No.2 No.3 No.4 No.5 No.618 18~50 18 18~50 18 18~50 18 18 18~50 18 18 18~50 18 18 18~5018 25~50 18 25~50 18 18~50 18 25 25~35 18 18 18~50 18 25 25~3518 35~50 35 35~50 18 18~50 18 35 35 18 18 18~50 18 35 3525 25~50 25 25~50 18 18~50 25 25 25~35 18 18 18~50 25 25 25~3535 35~50 35 35~50 25 25~50 18 18 18~50 18 25 25~35 18 18 18~50

25 25~50 18 25 25~35 18 25 25~35 18 25 25~3525 25~50 18 35 35 18 25 25~35 18 35 3525 25~50 25 25 25~35 18 25 25~35 25 25 25~3535 35~50 18 18 18~50 18 35 35 18 18 18~5035 35~50 18 25 25~35 18 35 35 18 25 25~3535 35~50 18 35 35 18 35 35 18 35 3535 35~50 25 25 25~35 18 35 35 25 25 25~35

25 25 25~35 18 18 18~5025 25 25~35 18 25 25~3525 25 25~35 18 35 3525 25 25~35 25 25 25~35

For full technical details, refer to Technical Manual

RAC Multi Split Systems

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 49: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Twin, Triple and Quad Splits Utopia ES, Centrifugal and IVX Systems

Utopia ES

The ‘ES’ range is small and compact; the units have only one fan (7.0 kW — 16kW models)

Common cabinet size and exterior of the Utopia ES and Utopia IVX allows for the units to be installed together creating a uniform appearance

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

Utopia IVX Centrifugal

Hitachi’s range of Utopia Centrifugal units can be installed indoors with field supplied ductwork and are therefore ideal for situations where installations have to be hidden or where circumstances do not allow for the use of traditional styled outdoor units

Low temperature operations

Wide working range including outdoor unit fan control in cooling mode for operating at low ambient temperature as standard (-5ºC to 43ºC cooling)

Compatible with all Hitachi System Free indoor units

Individual indoor unit control with an increased number of twins, triple and quad combinations

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols

H-LINK wiring system requires only two transmission wires connecting each indoor unit and outdoor unit for up to 16 refrigerant cycles, and connecting wires for all indoor units and all outdoor units in series.

Page 50: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 51

Product SummaryUtopia ES Utopia IVX System Utopia Centrifugal

Twin, Triple & Quad Splits Twin, Triple & Quad Splits Twin, Triple & Quad Splits

Nominal Cooling Capacity (kW) 7.1 ~ 25.0 7.1 ~ 30.0 7.1 ~ 25.0

Nominal Heating Capacity (kW) 8.0 ~ 28.0 8.0 ~ 33.5 8.0 ~ 28.0

Refrigerant R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter

Operating Range (Cooling) (db) -10ºC / +43ºC (-15ºC ~ +46ºC) db (*) -5ºC / +43ºC

Operating Range (Heating) (wb) -15ºC / +15ºC (-20ºC / +15ºC) wb -15ºC / +15ºC

Indoor Unit Type All System Free Indoor units (inc mixed Indoor units on a system)

Remote Controller Type Wired or Infra Red

Remote Control Timer 24hr or 7 Day option

Condenser Air Direction - - Adjustable

(*) -5 3.0~6.0 models

Utopia IVX

The Utopia IVX is a very efficient product and is a further development on its predecessor which was presented the “Shoeene Taishou” (Energy Efficiency Award) by the Japanese Government

COP of 4.10 and EER of 3.90

The optimised refrigerant circuit increases seasonal COP for heating and seasonal EER for cooling by 4%

The unit uses a horizontal discharge twin fan design allowing for a more efficient use of floor space

Individual indoor unit control with an increased number of twins, triple and quad combinations (90-115% diversity - 4, 5 and 6HP models)

Common cabinet size and exterior of the IVX and Utopia ES allows for the units to be installed together creating a uniform appearance

The Utopia IVX changes the way we think about twin, triple and quad split configurations and is the perfect choice for installations requiring individual unit control but have no need for the piping length capabilities available with more expensive VRF systems

By the use of individual control we can create a more comfortable environment for rooms that have unbalanced loads. This also leads to more economical operation as units not requiring operation will stop, reducing wasted energy

7 day timer

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web

Optional integration with all leading BMS protocols.

High-load Area Low-load Area

Indoor Temperature24°C

Set Temp.24°C

Continued Operation Stopped

Comfortable ComfortableIVX SYSTEM

Comfortable

Indoor Temperature25°C

Page 51: 2012 A5 Product Catalogue FULL (3)

RAS-H(V)RNM2E RAS-H(V)RNM2E RAS-HRNM

Utopia IVXOutdoor 1Ø RAS 3.0HVRNM2E RAS 4.0HVRNM2E RAS 5.0HVRNM2E RAS 6.0HVRNM2E

Outdoor 3Ø - RAS 4.0HRNM2E RAS 5.0HRNM2E RAS 6.0HRNM2E

Possible Combinations

Single 3.0 - 4.0 - 5.0 - 6.0 -

Twin 1.5 1.5 Connected Capacity 90% ~ 115% (3.6 ~ 4.6HP)

Connected Capacity 90% ~ 115% (4.5 ~ 5.8HP)

Connected Capacity 90% ~ 115% (5.4 ~ 6.9HP)Triple -

Quad - Min Indoor Capacity 0.8HP Min Indoor Capacity 0.8HP Min Indoor Capacity 0.8HP

Utopia IVX RAS 8.0HRNM RAS 10.0HRNM RAS 12.0HRNM

Possible Combinations

Single 8.0 - - - 10.0 - - - - - - -

Twin4.0 4.0 - - 6.0 4.0 - - 6.0 6.0 - -

5.0 3.0 - - 5.0 5.0 - - - - - -

Triple

3.0 3.0 3.0 - 3.0 3.0 3.0 - 4.0 4.0 4.0 -

3.0 3.0 2.5 - 4.0 3.0 3.0 - -

3.0 2.5 2.5 - - -

3.0 3.0 2.3 - - -

Quad

2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0

2.5 2.5 2.0 2.0 3.0 3.0 2.5 2.0 4.0 3.0 3.0 2.5

2.5 2.0 2.0 2.0 3.0 2.5 2.5 2.5 4.0 3.0 2.5 2.5

2.5 2.5 1.8 1.8 3.0 3.0 2.0 2.0 3.0 3.0 3.0 2.5

2.5 2.3 1.8 1.8 3.0 2.5 2.5 2.0 3.0 3.0 2.5 2.5

2.5 2.0 2.0 1.8 3.0 3.0 2.3 2.3 4.0 4.0 2.3 2.3

2.3 2.3 1.8 1.8 3.0 3.0 2.3 2.0 4.0 3.0 3.0 2.3

2.3 2.0 2.0 1.8 3.0 2.5 2.5 2.3 4.0 3.0 2.5 2.3

Twin, Triple and Quad Splits | ES

Utopia Split Systems

Utopia ESOutdoor 1Ø RAS 3.0HVRNS2 RAS 4.0HVRNS2E RAS 5.0HVRNS2E RAS 6.0HVRNS2E - -

Outdoor 3Ø - RAS 4.0HRNS2E RAS 5.0HRNS2E RAS 6.0HRNS2E RAS 8.0HRNSE RAS 10.0HRNSE

Possible Combinations

Single 3.0 - 4.0 - 5.0 - 6.0 - - 8.0 - 10.0 -

Twin

1.5 1.5 2.0 2.0 2.5 2.5 3.0 3.0 - 4.0 4.0 5.0 5.0

- 2.0 2.0 2.5 2.5 3.0 2.5 - -

- 2.3 2.0 3.0 2.3 - -

- 2.5 1.8 3.0 1.8 - -

Triple

- 2.5 2.0 1.8 1.8 1.8 3.0 3.0 3.0 - -

- - - 2.0 2.0 2.0 - -

- - - 2.0 2.0 1.8 - -

- - - 2.0 1.8 1.8 - -

- - - 2.5 1.5 1.5 - -

Quad - - - 2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5

RAS-HVRNS2 RAS-HVRNS2E RAS-HRNSE

Twin, Triple and Quad Splits | IVX

For full technical details, refer to Technical Manual.Please refer to individual product pages for dimensional data.

Page 52: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 53

Utopia Split Systems

Twin, Triple and Quad Splits | IVX CentrifugalRASC-H(V)RN(M)E

Utopia Centrifugal

Outdoor 1Ø RASC 3.0HVRNE RASC 5.0HVRNME -

Outdoor 3Ø - - RASC 10.0HRNME

Possible Combinations

Single 3.0 - 5.0 - - - 10.0 -

Twin1.5 1.5 2.5 2.5 - - 6.0 4.0

- 3.0 2.3 - - 5.0 5.0- - - - - 8.0 2.0

Triple- 1.8 1.8 1.5 - 3.0 3.0 3.0 -

- - 4.0 3.0 3.0 -

Quad

- - 2.5 2.5 2.5 2.5

- - 3.0 3.0 2.5 2.0

- - 3.0 2.5 2.5 2.5

- - 3.0 3.0 2.0 2.0

- - 3.0 2.5 2.5 2.0

- - 3.0 3.0 2.3 2.3

- - 3.0 3.0 2.3 2.0

- - 3.0 2.5 2.5 2.3

* 3HP Std. Inverter Centrifugal

For full technical details, refer to Technical Manual.Please refer to individual product pages for dimensional data.

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 53: 2012 A5 Product Catalogue FULL (3)

System Free Indoor Units

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0Size 20 25 - 35 42 50 60 - 71 100

Wall Mounted RPK-FSN2MNominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3 7.1 10.0Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0 8.0 11.2UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9 7.5 10.6UK Sensible Cooling (kW) 1.5 1.9 2.3 2.7 3.1 3.8 4.1 4.4 5.6 7.5

RPK-FSN2M

Twin, Triple and Quad Splits

RCD-FSN2

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0Size 20 25 - 35 42 50 60 - 71 100 125

2-Way Cassette RCD-FSN2(including grille) Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3 7.1 10.0 12.5

Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0 8.0 11.2 14.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9 7.5 10.6 13.1UK Sensible Cooling (kW) 1.7 2.1 2.3 2.7 3.2 4.0 4.1 4.4 5.6 7.7 9.0

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0Size 20 25 - 35 42 50 60 - 71 100 125 140

4-Way Cassette RCI-FSN3E(including grille) Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3 7.1 10.0 12.5 14.0

Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0 8.0 11.2 14.0 16.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9 7.5 10.6 13.1 15.6UK Sensible Cooling (kW) 1.7 2.1 2.5 2.8 3.4 4.1 4.0 4.3 5.9 8.3 9.7 11.4

HP 0.8 1.0 1.3 1.5 1.8 2.0Size 20 25 - 35 42 50

Mini 4-Way Cassette

RCIM-FSN2Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0

(including grille) Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3UK Sensible Cooling (kW) 1.6 1.9 2.4 2.7 3.1 3.8

RCIM-FSN2

RCI-FSN3E

S Y S T E MFREE

Capacity achieved via dip switch setting capacity range (HP) Model allows dipswitch adjustment+

For full technical details, refer to Technical Manual. Please refer to individual product pages for dimensional data.

Page 54: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 55

RPIM-FSN2E RPI-FSN2E

HP 0.8 1.0 1.3 1.5Size 20 25 - 35

Mini In the Ceiling RPIM-FSN2E

(Slim Width) Nominal Cooling (kW) 1.9 2.5 3.0 3.6Nominal Heating (kW) 2.2 2.8 3.4 4.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7UK Sensible Cooling (kW) 1.7 2.1 2.3 2.6

HP 0.8 1.0 1.3 1.5Size 20 25 - 35

In the Ceiling RPI-FSN2E

(Low Height) Nominal Cooling (kW) 1.9 2.5 3.0 3.6Nominal Heating (kW) 2.2 2.8 3.4 4.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7UK Sensible Cooling (kW) 1.7 2.1 2.3 2.7

HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0Size 42 50 60 - 71 100 125 140

Ceiling RPC-FSN2ESuspended Nominal Cooling (kW) 4.4 5.0 5.7 6.3 7.1 10.0 12.5 14.0

Nominal Heating (kW) 5.0 5.6 6.4 7.0 8.0 11.2 14.0 16.0UK Total Cooling (kW) 4.3 5.3 5.5 5.9 7.5 10.6 13.1 15.6UK Sensible Cooling (kW) 3.1 3.8 4.0 4.2 5.4 7.6 9.4 11.2

RPC-FSN2E

HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0 8.0 10.0Size 42 50 60 - 71 100 125 140 200 250

In the Ceiling RPI-FSN3E(Standard) Nominal Cooling (kW) 4.4 5.0 5.7 6.3 7.1 10.0 12.5 14.0 20.0 25.0

Nominal Heating (kW) 5.0 5.6 6.4 7.0 8.0 11.2 14.0 16.0 22.4 28.0UK Total Cooling (kW) 4.3 5.3 5.5 5.9 7.5 10.6 13.1 15.6 18.0 22.0UK Sensible Cooling (kW) 3.3 4.0 4.2 4.5 5.6 7.7 9.4 11.2 13.9 17.4

RPI-FSN3E

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 - 35 42 50 60 -

Floor Mounted RPFI-FSN2EUncased Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3

Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9UK Sensible Cooling (kW) 1.5 1.9 2.3 2.7 3.1 3.9 4.0 4.3

RPFI-FSN2E

System Free Indoor Units

Twin, Triple and Quad SplitsS Y S T E MFREE

Capacity achieved via dip switch setting capacity range (HP) Model allows dipswitch adjustment+

For full technical details, refer to Technical Manual. Please refer to individual product pages for dimensional data.

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 55: 2012 A5 Product Catalogue FULL (3)

Model Description

PC-ART Standard Wired Remote Controller (inc. 7 Day Time Clock)

PC-ARF Wired LED Controller with advanced graphical interface (inc 7 Day Time Clock)

PC-ARH Simple Wired Remote Controller

PC-LH3A Wireless Remote Controller (Receiver kit required inc. with RPK-FSN2M)

PC-ALHN Receiver Kit panel mounted (RCI-FSN3E)

PC-ALHD Receiver Kit panel mounted (RCD-FSN2)

PC-ALHC Receiver Kit panel mounted (RCIM-FSN2)

PC-ALHZ Receiver Kit wall mounted (All System Free Indoor Units)

TE-03N Twin Pipe Kit (3HP System)

TE-04N Twin Pipe Kit (4HP System)

TE-56N Twin Pipe Kit (5 & 6HP System)

TE-08N Twin Pipe Kit (8HP System)

TE-10N Twin Pipe Kit (10 & 12HP System)

TRE-06N Triple Pipe Kit (4 ~ 6HP System)

TRE-810N Triple Pipe Kit (8 ~ 12HP System)

QE-810N Quad Pipe Kit (8 ~ 12HP System)

E-102SN2 Piping Kit (Only use with 8 ~ 12HP Utopia IVX)

E-162SN2 Piping Kit (Only use with 8 ~ 12HP Utopia IVX)

RPF-FSN2E

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 - 35 42 50 60 -

Floor Standard RPF-FSN2ECased Nominal Cooling (kW) 1.9 2.5 3.0 3.6 4.4 5.0 5.7 6.3

Nominal Heating (kW) 2.2 2.8 3.4 4.0 5.0 5.6 6.4 7.0UK Total Cooling (kW) 2.1 2.6 3.2 3.7 4.3 5.3 5.5 5.9UK Sensible Cooling (kW) 1.5 1.9 2.3 2.7 3.1 3.9 4.0 4.3

System Free Indoor Units

Twin, Triple and Quad Splits

System Free Accessories

For full technical details, refer to Technical Manual.For centralised controllers and BMS interfaces see page 88

S Y S T E MFREE

Capacity achieved via dip switch setting capacity range (HP) Model allows dipswitch adjustment+

For full technical details, refer to Technical Manual. Please refer to individual product pages for dimensional data.

Page 56: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 57

Utopia AHU Interface

Control Box EXV-2.0E1* EXV-2.5E1* EXV-3.0E1* EXV-4.0E1* EXV-5.0E1* EXV-6.0E1* EXV-8.0E1* EXV-10.0E1*

Dimensions (mm) & Weight (kg)

Height 291

Width 241

Depth 87

Weight 3.2 3.5

Power Supply 1 Phase 1Ph 220-240V 50Hz

Allowed Fan Current (A) 2.5 15

Expansion Valve Box EXV-2.0E1* EXV-2.5E1* EXV-3.0E1* EXV-4.0E1* EXV-5.0E1* EXV-6.0E1* EXV-8.0E1* EXV-10.0E1*

Dimensions (mm) & Weight (kg)

Height 431

Width 199

Depth 103

Weight 2.7 4.5

For full technical details, refer to Technical Manual

Outdoor UnitDX-Kit

Allowed Heat Exchanger Capacity (kW) Heat Exchanger Volume (dm3)

Utopia IVX Utopia ES Code Mode Nominal Min Max Min Max

- RAS 2HVRN2 EXV-2.0ECooling 5.0 4.0 5.6

0.57 1.16Heating 5.6 4.5 7.1

- RAS 2.5HVRN2 EXV-2.5ECooling 6.0 4.8 6.3

0.89 1.35Heating 7.0 5.6 7.1

RAS 3HVRNM2E RAS 3HVRNS2 EXV-3.0ECooling 7.1 5.7 8.0

1.03 1.57Heating 8.0 6.4 9.0

RAS 4H(V)RNM2E RAS 4H(V)RNS2E EXV-4.0ECooling 10.0 8.0 11.2

1.51 2.37Heating 11.2 9.0 12.5

RAS 5H(V)RNM2E RAS 5H(V)RNS2E EXV-5.0ECooling 12.5 10.0 14.0

1.92 2.37Heating 14.0 11.2 16.0

RAS 6H(V)RNM2E RAS 6H(V)RNS2E EXV-6.0ECooling 14.0 11.2 16.0

1.92 2.92Heating 16.0 12.8 18.0

RAS 8HRNM RAS 8HRNS EXV-8.0ECooling 20.0 16.0 22.4

2.92 3.89Heating 22.4 17.9 25.0

RAS 10HRNM RAS 10HRNS EXV-10.0ECooling 25.0 20.0 28.0

3.89 4.76Heating 28.0 22.4 31.5

Twin, Triple and Quad Splits

Page 57: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Set Free VRF Systems

Control SystemsMini

2-pipeFS(V)N(Y)(2)(E.)

Sideflow2-pipeFSNM

Modular2-pipeFSXN

Modular3-pipeFSXN

Nominal Cooling Capacity (kW) 8.0 ~ 16.0 22.4 ~ 33.5 22.4 ~ 150.0 22.4 ~ 150.0

Nominal Heating Capacity (kW) 9.0 ~ 18.0 25.0 ~ 37.5 25.0 ~ 165.0 25.0 ~ 165.0

Power Supply 1Ø / 3Ø 3Ø 3Ø 3Ø

Refrigerant R410A R410A R410A R410A

Capacity Control DC-Inverter DC-Inverter DC-Inverter DC-Inverter

Operating Range (Cooling) (db) -5ºC / +43ºC -15ºC / +43ºC -5ºC / +43ºC -5ºC / +43ºC

Operating Range (Heating) (wb) -20ºC / +15ºC -20ºC / +15ºC -15ºC / +15ºC -20ºC / +15ºC

Connection Ratio 50 ~ 130% 50 ~ 130% 50 ~ 130% 50 ~ 130%

Indoor Unit Quantity 1 ~ 9 1 ~ 10 1 ~ 64 1 ~ 64

Indoor Unit Type All System Free Indoor Units

Control Systems Individual, groups, centralised and BMS

All Set Free VRF Systems

coil temperature setting on all indoor units

whole range

loads and energy savings

Individual control options are Infra red remote controller with 24hr timer, simplified hard wired controller or hard wired remote controller with built in 7-day timer.

FS(V)(Y)N2E Mini 2-pipe

COP of 4.14 and EER of 4.07.

Page 58: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 59

FSNM 2-pipe

Any combination of 10 System Free indoor units with a total diversity of 50-130% can be individually controlled

The unit uses a horizontal discharge twin fan design allowing for more efficient use of floor space.

FSXN Modular 2 or 3-pipe

3-pipe heat recovery to suit customer requirements

Two highly-effective heat pump systems in one unit:A two-pipe system for open plan environments and a three-pipe system for individual spaces, allowing your customers to tailor their air conditioning needs to meet a diverse range of building requirements

Select from 3 settings with up to 8dB noise reduction.

Page 59: 2012 A5 Product Catalogue FULL (3)

Hitachi FSXN VRF

Offer 2-pipe and 3-pipe options from a single unit for air conditioning that can be tailored to meet changing building requirements

Visit hitachiaircon.com/tomorrowto find out more

Page 60: 2012 A5 Product Catalogue FULL (3)

RAS-FSVNE

Mini 2-pipe

Outdoor 1Ø RAS-3FSVNE RAS-4FSVN2E RAS-5FSVN2E RAS-6FSVN2EOutdoor 3Ø - RAS-4FSNY2E RAS-5FSNY2E RAS-6FSNY2E

Nominal Capacity (kW)Cooling 8.0 11.2 14.0 15.5Heating 9.0 12.5 16.0 18.0

UK Cooling Capacity (kW) Total 7.4 10.4 13.0 14.4

EER/COP Cooling 3.54 4.07 3.61 3.32Heating 3.59 4.14 3.81 3.67

Maximum number of Indoor Units No. 4 6 8 9Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 45 (41) 49 (45) 51 (47) 51 (48)Heating 47 51 53 53

Dimensions (mm) & Weight (kg)

Height 800 1380Width 850 950Depth 315 370Weight 66 97 97 97

Operating Range (ºC)Cooling -5ºC / +43ºC (db) -5ºC / +46ºC (db)Heating -20ºC / +15ºC (wb)

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)Gas 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)

Piping (m)Total Length 65 125 125 125

Lift 25 30 30 30Pre-charged Calculate Calculate Calculate Calculate

Power Supply1Ø 220-240V 50Hz

- 3Ph 380-415V 50HzStarting Current (1Ø/3Ø) (A) 7.0 / - 10.5 / 5.0 15.0 / 5.0 15.0 / 5.0

Running Current (1Ø/3Ø) (A)Cooling 9.6 / - 12.2 / 4.1 17.2 / 5.8 20.7 / 7.0Heating 10.7 / - 13.4 / 4.6 18.6 / 6.3 21.7 / 7.4

Recommended Fuse Size (1Ø/3Ø) (A) 25 / - 25 / 16 32 / 16 32 / 16

RAS 8FSNM RAS 10FSNM RAS 12FSNM

Nominal Capacity (kW)Cooling 22.4 28.0 33.5Heating 25.0 31.5 37.5

UK Cooling Capacity (kW) Total 20.8 26.0 31.2

EER/COP (Outdoor Only)Cooling 3.56 3.37 3.13Heating 4.24 4.04 3.79

Maximum number of Indoor Units No. 10 10 10Outdoor Sound Pressure Level (Set Back) dB(A)

Cooling 53 (50) 56 (53) 59 (55)Heating 55 58 55

Dimensions (mm) & Weight (kg)

Height 1650Width 1100Depth 390Weight 170 170 173

Operating Range (ºC)Cooling (-5 ~ 43)dbHeating (-20 ~ 15)wb

Refrigerant Piping (mm) (in)Liquid 9.52(3/8) 12.7(1/2) 12.7(1/2)Gas 19.05 (3/4) 22.20 (7/8) 22.20 (7/8)

Piping (m)Total Length 250 250 250

Lift 40 40 40Pre-charged Calculate Calculate Calculate

Power Supply 3Ø 380-415V 50HzStarting Current (A) 8 8 8

Running Current (A)Cooling 9.4 12.4 15.8Heating 8.8 11.7 14.7

Recommended Fuse Size (A) 16 20 25

RAS FSNM

RAS-FS(V)(Y)N2E

Sideflow 2-pipe

Set Free VRF Systems

Hitachi Product Catalogue | 61

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 61: 2012 A5 Product Catalogue FULL (3)

Modular

Set Free VRF Systems

RAS 8FSXN RAS 10FSXN RAS 12FSXN RAS 14FSXN RAS 16FSXN RAS 18FSXN

Nominal Capacity (kW)Cooling 22.4 28.0 33.5 40.0 45.0 50.0Heating 25.0 31.5 37.5 45.0 50.0 56.0

UK Cooling Capacity (kW) Total 19.3 24.1 28.8 34.4 38.7 43.0

EER/COP (Outdoor)Cooling 3.85 3.79 3.41 3.25 3.23 3.37Heating 4.17 4.11 3.60 3.89 3.90 3.81

Maximum number of Indoor Units No. 13 16 19 23 26 26

Outdoor Sound Pressure Level (Set Back) dB(A) Cooling 58 (53) 58 (53) 60 (55) 62 (57) 62 (57) 63 (58)

Dimensions (mm) & Weight (kg)

Height 1720 1720 1720 1720 1720 1720Width 950 950 950 1210 1210 1210Depth 765 765 765 765 765 765Weight 225 225 225 315 315 335

Operating Range (ºC)Cooling -5ºC / +43ºCHeating -20ºC / +15ºC

Refrigerant Piping (mm) (in) Liquid 9.53 (3/8) 9.53 (3/8) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 15.88 (5/8)

Gas 19.05 (3/4) 22.22 (7/8) 28.57 (1 1/8) 28.57 (1 1/8) 28.57 (1 1/8) 28.57 (1 1/8)

Piping (m)Max. Length 1000 1000 1000 1000 1000 1000

Lift 50 50 50 50 50 50Pre-charged Calculate Calculate Calculate Calculate Calculate Calculate

Power Supply 3Ø 380-415V 50HzStarting Current (A) 8 8 8 95 95 113

Running Current (A)Cooling 9.3 11.9 15.7 20.2 22.6 24.1Heating 9.6 12.3 16.7 18.8 20.8 23.8

Recommended Fuse Size (A) 16 20 25 32 32 32

Model RAS 20FSXN RAS 22FSXN RAS 24FSXN RAS 26FSXN RAS 28FSXN RAS 30FSXN

CombinationsRAS 8FSXN RAS 8FSXN RAS 10FSXN RAS 12FSXN RAS 14FSXN RAS 14FSXN

RAS 12FSXN RAS 14FSXN RAS 14FSXN RAS 14FSXN RAS 14FSXN RAS 16FSXN

Model RAS 32FSXN RAS 34FSXN RAS 36FSXN RAS 38FSXN RAS 40FSXN RAS 42FSXN

CombinationsRAS 16FSXN RAS 16FSXN RAS 18FSXN RAS 12FSXN RAS 12FSXN RAS 12FSXNRAS 16FSXN RAS 18FSXN RAS 18FSXN RAS 12FSXN RAS 12FSXN RAS 12FSXN

- - - RAS 14FSXN RAS 16FSXN RAS 18FSXN

Model RAS 44FSXN RAS 46FSXN RAS 48FSXN RAS 50FSXN RAS 52FSXN RAS 54FSXN

CombinationsRAS 12FSXN RAS 12FSXN RAS 12FSXN RAS 14FSXN RAS 16FSXN RAS 18FSXNRAS 14FSXN RAS 16FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXNRAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN RAS 18FSXN

Combinations

For full technical details, refer to Technical Manual

RAS FSXN

Page 62: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 63

System free Indoor Units

Set Free VRF Systems

RCD-FSN2

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0

Size 20 25 32 40 - 50 - 63 71 100 125

2-Way Cassette RCD-FSN2

(including grille) Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1 8.0 11.2 14.0

Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5 9.0 12.5 16.0

UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4 7.5 10.5 12.7

UK Sensible Cooling (kW) 1.7 2.1 2.5 2.8 3.2 3.9 4.4 4.7 5.6 7.7 8.8

RCI-FSN3E

HP 0.8 1.0 1.3 1.5 1.8 2.0

Size 20 25 32 40 - 50

Mini 4-Way Cassette RCIM-FSN2

(including grille) Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6

Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3

UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2

UK Sensible Cooling (kW) 1.6 1.9 2.5 2.9 3.1 3.7

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0

Size 20 25 32 40 - 50 - 63 71 100 125 140

4-Way Cassette RCI-FSN3E

(including grille) Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1 8.0 11.2 14.0 16.0

Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5 9.0 12.5 16.0 18.0

UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4 7.5 10.5 12.7 14.8

UK Sensible Cooling (kW) 1.7 2.1 2.6 3.0 3.4 4.1 4.4 4.7 5.9 8.2 9.4 10.8

CH-6.0N1 CH-10.0N1

Nominal Capacity HP HP 6 6 < HP 10Maximum number of Indoor Units - 7 8Input power Watts 20 20

Dimensions (mm) & Weight (kg)

Height 191 191Width 301 301Depth 214 214Weight 7 7

Refrigerant - R410A (charged with nitrogen to avoid corrosion)Refrigerant pipe connections Flared connections with nuts and/or flange (factory-supplied)

Refrigerant lines from the outdoor unit(1)

Low pressure ø15.88mm (5/8") ~ ø19.05mm (3/4") ø19.05mm (3/4") ~ ø22.2mm (7/8")High pressure ø12.7mm (1/2") ~ ø15.88mm (5/8") ø15.88mm (5/8") ~ ø19.05mm (3/4")

Refrigerant lines from the indoor unit(1)

Liquid line As appropriate for indoor unit capacity (bypasses CH Box)Gas line ø12.7mm (1/2") ~ ø15.88mm (5/8") ø19.05mm (3/4") ~ ø22.2mm (7/8")

CH Boxes

For full technical details, refer to Technical Manual

RCIM-FSN2

S Y S T E MFREE

Capacity available with dip switch setting capacity range (HP) Adjustable by dipswitch setting+

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 63: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical ManualFor our full range of controls and accessories see pages 88 and 89.

System free Indoor Units

Set Free VRF Systems

RPI-FSN2E

HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0 8.0 10.0Size - 50 - 63 71 100 125 140 200 250

In the Ceiling RPI-FSN3E(Standard) Nominal Cooling (kW) 5.0 5.6 6.5 7.1 8.0 11.2 14.0 16.0 22.4 28.0

Nominal Heating (kW) 5.7 6.3 7.8 8.5 9.0 12.5 16.0 18.0 25.0 31.0

UK Total Cooling (kW) 4.3 5.2 6.0 6.4 7.5 10.5 12.7 14.8 18.4 22.9

UK Sensible Cooling (kW) 3.3 4.0 4.6 4.9 5.6 7.7 9.1 10.7 14.2 18.1

RPI-FSN3E

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0Size 20 25 32 40 - 50 - 63 71 100

Wall Mounted RPK-FSN2MNominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1 8.0 11.2

Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5 9.0 12.5

UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4 7.5 10.5

UK Sensible Cooling (kW) 1.5 1.9 2.5 2.8 3.1 3.7 4.5 4.8 5.6 7.5

RPK-FSN2M

HP 0.8 1.0 1.3 1.5Size 20 25 32 40

Mini In The Ceiling RPIM-FSN2E(Slim Width) Nominal Cooling (kW) 2.2 2.8 3.8 4.0

Nominal Heating (kW) 2.5 3.2 4.3 4.8

UK Total Cooling (kW) 2.1 2.6 3.4 3.9

UK Sensible Cooling (kW) 1.7 2.1 2.4 2.8

RPIM-FSN2ERPIM FSN E

HP 0.8 1.0 1.3 1.5Size 20 25 32 40

In the Ceiling RPI-FSN2E(Low Height) Nominal Cooling (kW) 2.2 2.8 3.8 4.0

Nominal Heating (kW) 2.5 3.2 4.3 4.8

UK Total Cooling (kW) 2.1 2.6 3.4 3.9

UK Sensible Cooling (kW) 1.7 2.1 2.4 2.8

HP 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0Size - 50 - 63 71 100 125 140

Ceiling Suspended RPC-FSN2ENominal Cooling (kW) 5.0 5.6 6.5 7.1 8.0 11.2 14.0 16.0

Nominal Heating (kW) 5.7 6.3 7.8 8.5 9.0 12.5 16.0 18.0

UK Total Cooling (kW) 4.3 5.2 6.0 6.4 7.5 10.5 12.7 14.8

UK Sensible Cooling (kW) 3.1 3.7 4.3 4.6 5.4 7.6 9.1 10.7

RPC-FSN2E

S Y S T E MFREE

Capacity available with dip switch setting capacity range (HP) Adjustable by dipswitch setting+

Page 64: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 65

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 32 40 - 50 - 63

Floor Mounted RPFI-FSN2EUncased Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1

Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4UK Sensible Cooling (kW) 1.5 1.9 2.5 2.8 3.1 3.8 4.4 4.7

RPFI-FSN2E

RPF-FSN2E

HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5Size 20 25 32 40 - 50 - 63

Floor Mounted RPF-FSN2ECased Nominal Cooling (kW) 2.2 2.8 3.8 4.0 5.0 5.6 6.5 7.1

Nominal Heating (kW) 2.5 3.2 4.3 4.8 5.7 6.3 7.8 8.5UK Total Cooling (kW) 2.1 2.6 3.4 3.9 4.3 5.2 6.0 6.4UK Sensible Cooling (kW) 1.5 1.9 2.5 2.8 3.1 3.8 4.4 4.7

System free Indoor Units

Set Free VRF Systems

For full technical details, refer to Technical Manual

Model

PC-ARTStandard Wired Remote Controller (inc. 7 Day Time Clock)

PC-ARFWired LED Controller with advanced graphical interface (inc 7 Day Time Clock)

PC-ARH Simple Wired Remote Controller

PC-LH3AWireless Remote Controller (Receiver kit required inc. with RPK-FSN2M)

PC-ALHN Receiver Kit panel mounted (RCI-FSN3E)

PC-ALHD Receiver Kit panel mounted (RCD-FSN3E)

PC-ALHC Receiver Kit panel mounted (RCIM-FSN3E)

PC-ALHZ Receiver Kit wall mounted (All System Free Indoor Units)

System Free Accessories / Pipe Kits

Pipe Kits (Set Free - Mini, Side Flow, Modular)

E-102SN2 Pipe Kit (2-pipe)

E-162SN2 Pipe Kit (2-pipe)

E 242SN2 Pipe Kit (2-pipe)

E 302SN2 Pipe Kit (2-pipe)

E 52XN2 Pipe Kit (3-pipe)

E 102XN2 Pipe Kit (3-pipe)

E 162XN2 Pipe Kit (3-pipe)

E 202XN2 Pipe Kit (3-pipe)

E 242XN2 Pipe Kit (3-pipe)

E 322XN2 Pipe Kit (3-pipe)

MH 84AN Pipe Kit (2-pipe header)

MH 108AN Pipe Kit (2-pipe header)

MH 108XN Pipe Kit (3-pipe header)

S Y S T E MFREE

Capacity available with dip switch setting capacity range (HP) Adjustable by dipswitch setting+

HP 1.5 2.0 2.5Size 40 50 63m³/hr 500 800 1000

Active KPI KPI-X3ENominal Cooling (kW) 5.3 8.0 10.8Nominal Heating (kW) 6.9 9.8 12.9Coil Cooling Cap. (kW) 1.8 2.9 3.7Coil Heating Cap. (kW) 2.1 3.5 4.4

Pipe Kits (Set Free - Mini, Side Flow, Modular)

MC 20ANModular Set Free 2-pipe Branch Kit (RAS 20~24FSXN)

MC 21ANModular Set Free 2-pipe Branch Kit (RAS 26~36FSXN)

MC 30ANModular Set Free 2-pipe Branch Kit (RAS 28~54FSXN)

MC 20XNModular Set Free 3-pipe Branch Kit (RAS 20~24FSXN)

MC 21XNModular Set Free 3-pipe Branch Kit (RAS 26~36FSXN)

MC 30XNModular Set Free 3-pipe Branch Kit (RAS 28~54FSXN)

NEW

Available from June 2012Provisional Data

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 65: 2012 A5 Product Catalogue FULL (3)

Close Control

Features and Benefits

Twin DC Inverter

Specifically designed and developed to provide

a suitable environment for server and computer

rooms, telecommunications facilities and data

centres, where a need for high sensible cooling

and close control of temperature is required.

saving energy by reducing humidification

up to 160m with 70m* height difference

* special order

Page 66: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 67

Page 67: 2012 A5 Product Catalogue FULL (3)

Indoor Unit Outdoor Unit

RP 20ACRN RCR 20ACN

Nominal Capacity (kW) 56.6

Sensible Cooling Capacity (kW) 56

Sound Pressure Level (Set Back) dB(A) 60 57 (54)

Dimensions (mm) & Weight (kg)

Height 1900 1980

Width 2145 1800

Depth 900 900

Weight 925 410

Fan

Model & Quantity Multi Blade Centrifugal x 2 Propeller x 2

Nominal Air Flow Rate (m³/min) 350 300

Static Pressure (Pa) 120 (Max. 300) 0 (60)(*1)

Air Inlet Upper Side Lower Side (Front Side: Optional(*2))

Air Outlet Lower Side Upper Side

Operating Range (ºC) -15ºC ~ +43ºC

Refrigerant Piping (mm) (in)

Liquid 12.7 (1/2) x 2 (Equivalent piping > than 120m: 15.88 (5/8) x 2)

Gas 19.05 (3/4) x 2 (Equivalent piping > than 120m: 22.22 (7/8) x 2)

Direction Bottom (Top - Optional)(*3) Bottom or Front or Rear

Piping (m)

Max. Equivalent 185

Max. Length 160

Lift 40 (70 special order)(*4)

Pre-charged 50

Power Supply 3Ø 380~415V 50Hz

Starting Current (A) Less than Running Current (Maximum Running Current: 49.5A)

Running Current (A) 31.7

Recommended Fuse Size (A) TBC TBC

NOTES:

1. The performance is indicated when the unit is operated under the following conditions:

Indoor Inlet Air Temperature: 27°C DB, 19°C WB Outdoor Inlet Air Temperature: 35°C DB; Refrigerant Piping Length: 5m (one-way, installed horizontally) at rated compressor frequency

2. The sound pressure level is indicated the value (A scale) measured under the following conditions:

Measurement Points Indoor Unit: 1m from unit front surface, 1m from floor level Measurement Points Outdoor Unit: 1m from unit front surface, 1.5m from floor level The above data was measured in an anechoic room, so that reflected sound should be taken into consideration in the field. In the case that air inlet port is provided at front surface (*2), more affected by reflected sound.

3. The external static pressure and airflow rate of the fan may not reach the standard value due to air outlet dimension and shape, or obstacles.

4. (*1): Required custom-ordered modification at factory. (*2): Required air inlet grille (optional) mounting. (*3) (*4): Required indoor unit custom-ordered modification at factory.

Indoor Unit ACRN

Close Controller HD2 PCP

Outdoor Unit ACN

Close Control

Twin DC Inverter

For full technical details, refer to Technical Manual

Page 68: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 69

Close Control

Optional Accessories

Model

Condition

ApplicationsOptional Accessories

Modified at Factory

Indoor Unit

Modification for piping/wiring through top of unit - - Applicable Refrigerant piping and wiring is modified to connect

through the top of the unit

Modification for height difference up to 70m - - Applicable Applicable when the outdoor unit is installed higher

than the indoor unit

Connection piping set CPS-NP560L Applicable - When piping length is over 120m, piping diameter shall be sized up

Air inlet chamber BS-NP560D Applicable - When the duct is connected at air inlet side (upper part of the unit)

Temperature sensor THM-R2DM Applicable - When the multipoint temperature control is applied

Temperature-humidity sensor THU-R1D Applicable - When no-dehumidifying control or dehumidifying control by humidity sensor is applied

Outdoor Unit

Modification for high external static pressure switchover - - Applicable Modification for high external static pressure to be

switched over at control panel

Front side air inlet grille PN-NP560D Applicable - Modification to change air inlet from unit bottom side into unit front side

Bottom side protective grille PN-NP560SD Applicable - To prevent object from entering into unit

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 69: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Ventilation

KPI-Energy, Heat Recovery and Active models

3/h

The Hitachi heat recovery ventilation system (KPI) adjusts the temperature and humidity of incoming fresh air to match the indoor environment

The fan motor is the only moving part resulting in low noise levels of 26dB(A) (NR28)

Fresh air supply for indoor environments

Energy recovery ventilation between supply and extract air supplies (forced energy exchange mode) efficiencies up to 78%

Automatic ventilation (KPI controls which mode to operate within to achieve maximum energy efficiency)

Ventilation mode (forced bypass mode)

As a consequence of the energy exchange during the summer period, the cooling load can be reduced by up to 20%, minimising both capital and running costs

Easy access hatches for the heat exchanger, motor, fans and electrical box allow in situ maintenance

as standard control option

Individual control or interfaced with Hitachi System Free fan coil

Compatible with H-LINK II Control and CS Net Web.

Econofresh

The Econofresh kit is an intelligent accessory device that is easy to install. The Econofresh kit can provide up to 100% fresh air and has the ability to provide “free cooling” when the outdoor temperature is below the indoor setting temperature. This kit in conjunction with the RPI In the Ceiling system will not only maintain the correct room temperature and provide fresh air, but also natural cooling therefore increasing energy savings.

Fresh air cooling during intermediate seasons saves energy. This unit uses an economiser for cooling, which takes in fresh air if the outdoor temperature is cooler than the indoor air. No compressor is used and thus a remarkable amount of energy is saved

A fresh air intake system keeps the air in a room clean at all times. The optional CO2 sensor can sense the degree of pollution of the air in the room and automatically control the fresh air flow

Utilising the free cooling potential of the UK climate, the combination of the Econofresh and the RPI 5.0FSN3E can reduce the power input required by more than 20% when compared to a standard RPI 5.0FSN3E system

Hard wired remote controller with built in 7 day timer (as per RPI-FSN3E In the Ceiling unit)

Optional simplified hard wired or infra red remote controller with 24hr timer

Compatible with H-LINK II Control and CS Net Web controls that integrate with all leading BMS protocols.

Page 70: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 71

Product Summary KPI Energy Recovery KPI Heat Recovery Active KPI Econofresh

Model KPI-E3E (1) KPI-H3E (1) KPI-X3E (2) EF

Air Volume (m3/min) 250 ~ 2,000 500 ~ 2,000 500 ~ 1,000 21 ~ 210

Total Enthalpy Heat Exchange - -

Sensible Heat Exchange -

Bypass Ventilation -

Free Cooling 10 ~ 100%

DX Coil - - -

EC Fans - EuP Lot 11 2nd Tier Compliant -

Automatic Ventilation via CO2 Sensor input

High Efficiency Filter (F7 based on EN779) Option Option Option -

Power Supply 1Ø 220-240V 50Hz Power supplied from RPI 5.0FSN3E

Fan Coil Type Individual Requires RPI 5.0FSN3E

Remote Controller Type Wired or Infra Red

Remote Control Timer 24hr or 7 Day Option

(1) KPI-E3E and KPI-H3E Series models available from June 2012 (check with Hitachi Sales Office)

Series 2 KPI-E2E and KPI-H2E models will remain available until June 2012

(2) KPI-X3E models will be available from June 2012 (check with Hitachi Sales Office)

Page 71: 2012 A5 Product Catalogue FULL (3)

KPI Energy Recovery

Ventilation

Total Energy Recovery KPI 252E3E KPI 502E3E KPI 802E3E KPI 1002E3E KPI 1502E3E KPI 2002E3E

Air Flow Rate (m3/h) H/M/L 250-208-180 500-420-360 800-700-597 1000-800-620 1500-1250-970 2000-1560-1240

External Static Pressure (1) (Pa) H/M/L 60-40-30 77-50-47 100-75-55 120-80-50 132-90-60 135-84-60

Boost External Static Pressure (Pa) 200 (250m³/h) 227 (500m³/h) 200 (800m³/h) 195 (1000m³/h) 246 (1500m³/h) 180 (2000m³/h)

Sound Pressure Level (2) (dB(A) H/M/L 27-26-24 30-28-27 32-31-30 35-32-30 37-35-33 39-38-35

Heat Exchanger Element Air to Air cross flow Celluloid material (Total Energy Exchange)

Temp Exchange Efficiency (%) 75 75 75 78 78 78

Enthalpy Exchange Efficiency (Heat) 66 65 65 68 68 66.5

Enthalpy Exchange Efficiency (Cool) 60 61 62 62 62.5 61.5

Dimensions (mm) & Weight (kg)

Height 270 330 385 385 525 525

Width 900 1130 1210 1600 1800 1800

Depth 750 920 1015 1295 1130 1430

Weight TBC TBC TBC TBC TBC TBC

Duct Sizes (dia) (mm) 150 200 250 300 355 355

Supplied Air Filter Class (EN779) (4) G3 G3 G3 G3 G3 G3

Operation Range (3) -20 ~ 46°C

Power Supply 1 ~ 230V 50Hz

Running Current (230V) (A) 0.2 0.4 1.0 1.2 1.9 2.7

Recommended Fuse Size (A) 5 5 5 5 5 5

Series 3 KPI-E3E data is provisional (check with Hitachi Sales Office)

KPI-E3E and KPI-H3E Series models available from June 2012 (check with Hitachi Sales Office)

Series 2 KPI-E2E and KPI-H2E models will remain available until June 2012

For full technical details, refer to Technical Manual

Page 72: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 73

PC-ARTKPI-E(H)(2)E

KPI Heat Recovery

Ventilation

Heat Recovery KPI 502H3E KPI 802H3E KPI 1002H3E KPI 1502H3E KPI 2002H3E

Air Flow Rate (m3/h) H/M/L 500-420-360 800-700-597 1000-800-620 1500-1250-970 2000-1560-1240

External Static Pressure (1) (Pa) H/M/L 77-50-47 100-75-55 120-80-50 132-90-60 135-84-60

Boost External Static Pressure (Pa) 227 (500m³/h) 200 (800m³/h) 195 (1000m³/h) 246 (1500m³/h) 180 (2000m³/h)

Sound Pressure Level (2) (dB(A) H/M/L 30-28-27 32-31-30 35-32-30 37-35-33 39-38-35

Heat Exchanger Element Air to Air cross flow Aluminium material (Heat Exchange)

Temp Exchange Efficiency (%) 53 50 50 49 48

Enthalpy Exchange Efficiency (Heat) 35 34 33 31 31

Enthalpy Exchange Efficiency (Cool) 30 28 28 27 28

Dimensions (mm) & Weight (kg)

Height 330 385 385 525 525

Width 1130 1210 1600 1800 1800

Depth 920 1015 1295 1130 1430

Weight TBC TBC TBC TBC TBC

Duct Sizes (dia) (mm) 200 250 300 355 355

Supplied Air Filter Class (EN779) (4) G3 G3 G3 G3 G3

Operation Range (3) -20 ~ 46°C

Power Supply 1 ~ 230V 50Hz

Running Current (230V) (A) 0.4 1.0 1.2 1.9 2.7

Recommended Fuse Size (A) 5 5 5 5 5

Series 3 KPI-H3E data is provisional, (check with Hitachi Sales Office) KPI-E3E and KPI-H3E

Series models available from June 2012 (check with Hitachi Sales Office)

Series 2 KPI-E2E and KPI-H2E models will remain available until June 2012

If a KPI is operated individually add the PC-ART / PC-ARF remote controller to the price. For details of interlocks with Utopia & Set Free systems contact your local sales office. (1) Default fan pressure setting(2) Sound pressure level has been measured in an anechoic chamber, with the measuring point 1.5m below the centre of the unit,

with no ceiling under the unit and using a sound insulated duct. Reflected sound must be considered when installing the unit in the field.(3) The installation of an electric heater is necessary when temperature becomes lower than -5ºC(DB).(4) High efficiency filter class F7 (EN779) is available as accessory.

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 73: 2012 A5 Product Catalogue FULL (3)

Active KPI

Ventilation

Active - Total Energy Recovery

KPI 502X3E KPI 802X3E KPI 1002X3E

Hp 1.5 2.0 2.5

Size 40 50 63

Nominal Set Free Capacity (1) Brackets = Coil Cap. (kW)

Cooling 5.3 (1.8) 8.0 (2.9) 10.8 (3.7)

Heating 6.9 (2.1) 9.8 (3.5) 12.9 (4.4)

Nominal Utopia Capacity (1) Brackets = Coil Cap. (kW)

Cooling - 7.4 (2.9) 9.7 (3.7)

Heating - 9.1 (3.5) 11.4 (4.4)

Air Flow Rate (m³/h) H/M/L 500-430-380 800-700-590 1000-820-740

External Static Pressure (2) (Pa) H/M/L 150-120-100 125-95-70 120-85-70

Boost External Static Pressure (Pa) 235 (500m³/h) 125 (800m³/h) 125 (1000m³/h)

Sound Pressure Level (3) (dB(A) H/M/L 29-27-26 31-30-29 35-32-30

Heat Exchanger Element Air to Air cross flow Celluloid material (Total Energy Exchange)

Temp Exchange Efficiency (%) 75 75 78

Enthalpy Exchange Efficiency (Heat) 65 65 68

Enthalpy Exchange Efficiency (Cool) 61 62 62

Dimensions (mm) & Weight (kg)

Height 330 385 385

Width 1630 1710 2100

Depth 920 1015 1295

Weight TBC TBC TBC

Refrigerant Piping (mm (in))Liquid 6.35 (1/4) 6.35 (1/4) 9.53 (3/8)

Gas 12.7 (1/2) 15.88 (5/8) 15.88 (5/8)

Duct Sizes (dia) (mm) 200 250 300

Supplied Air Filter Class (EN779) (5) G3 G3 G3

Operation Range (4) -20 ~ 46°C

Power Supply 1 ~ 230V 50Hz

Running Current (230V) (A) 0.7 1.2 1.5

Recommended Fuse Size (A) 5 5 5

Series 3 KPI-X3E data is provisional, (check with Hitachi Sales Office)

KPI-X3E models will be available from June 2012 (check with Hitachi Sales Office)

If a KPI is operated individually add the PC-ART / PC-ARF remote controller to the price. For details of interlocks with Utopia & Set Free systems contact your local sales office. (1) The nominal cooling and heating capacity is the combined capacity of the outdoor and indoor units of the system and is based on Standard EN14511.(2) Default fan pressure setting.(3) Sound pressure level has been measured in an anechoic chamber, with the measuring point 1.5m below the centre of the unit, with no ceiling under the unit and

using a sound insulated duct. Reflected sound must be considered when installing the unit in the field.(4) The installation of an electric heater is necessary when temperature becomes lower than -5ºC(DB).(5) High efficiency filter class F7 (EN779) is available as accessory.

For full technical details, refer to Technical Manual

Page 74: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 75

EF-NE

New ModelModel descriptionEF 5NE

Econofresh KitRPI-5HP

Econofresh Kit EF 5NE

Dimensions (mm) & Weight (kg)

Height 254

Width 1350+59

Length 270

Weight 12.5

Typical Free Cooling Range (ºC) 3ºC ~ 19ºC

Power Supply Supplied from RPI 5FSN3E

Interconnecting Cables Supplied

Remote Controller Type via Indoor Unit Controller

Econofresh Kit

Ventilation

Econofresh Indoor Unit System

EF 5NE RPI 5FSN3E Utopia ES (5, 10HP)

EF 5NE RPI 5FSN3E Utopia IVX (5 ~ 12HP)

EF 5NE RPI 5FSN3E Utopia Centrifugal (5, 10HP)

EF 5NE RPI 5FSN3E Set Free - Mini, Side Flow, Modular

System Possibilities

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 75: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Domestic Heating

Yutaki-M – Monobloc air to water heat pump

A compact solution where a single unit is

installed on the outside of the property, taking up

no space inside and can be used alongside an

existing heating solution.

(55ºC for 4~6HP)

ideal boiler replacement technology

handling required

renewable heat incentive

holiday button and frost protection as standard

Yutaki-S – Split type air to water heat pump

A split system with auxiliary heating as standard.

separate outdoor unit

settings – ideal boiler replacement technology

(2HP model)

holiday button and frost protection as standard

Heating Manufacturer of the Year “ The judges felt Hitachi provided an excellent

submission, a great product and the way forward.”Hitachi’s Yutaki M Heat Pump

Page 76: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 77

Product Summaryyy YutYutYuY akikiaki M-M-M-M YutYYutYutakiakiak -S-SS

Model RHURHURH E-AE-AE-A(V)(V)(V HN(HN(HN(1)-1)-1 (HM(HM(HMHM)) RWMRWMRW -FS-FS-FSN3EN3EE RWMRWMWM-HF-HFSN3SN3EE

Nominal Heatttatiingingi Ca Capacity (kW) 7.17.17 1 ~ ~ 17.1717.55 2.32.33 ~ ~ 32.3232.2222 2.32.3 ~ ~ 32.332.2 22

Nominal CCCCooloo ingng Capacity (kW) - 1.81.88 ~ ~ ~ 20.20.0 888 -

Refrigggeeraeraerantntnt R4R41R44 0A0A0A R41R41R 0A0A0A R41R41R4110A0A00A0A

Capapapapacicityty Control DC-InInverterte erer DC-DC-DCDC InvIInvInvertertererer DCCCDC-Invnverterterer

Operating Range (Heating) (wb) -20ºC / ++37.5ºC5ºC -2 -220ºC0º0ºC / / +35+35+353 ºCºCºCC -2 -20ºC0ºC / / +35+ ºC

Operatinng Range (Cooling) (db) - -10-10ºC ºC C / +/ +/ +/ ++46º46º46º46º6 CCCC -

Energy RRating A AAA A

Remote Controller Type Wireless Wireless

Remote CCoC ntrol Timer 24hr or 7 Day option 24hr or 7 Day option

Page 77: 2012 A5 Product Catalogue FULL (3)

Domestic Heating

Yutaki-M

Outdoor 1Ø RHUE 3.0AVHN1 RHUE 4.0AVHN-HM RHUE 5.0AVHN-HM RHUE 6.0AVHN-HM

Outdoor 3Ø - - RHUE 5.0AHN-HM RHUE 6.0AHN-HM

Capacity1 Nominal (min~max) (kW) Water (in/out) 30/35ºC 7.5 (6.2 ~ 11.0) 9.5 (5.0 ~ 10.9) 12.0 (6.9 ~ 15.0) 14.0 (7.8 ~ 17.5)

COP Ambient (db/wb) 7/6ºC 4.43 4.06 4.01 4.31

Capacity2 Nominal (min~max) (kW) Water (in/out) 40/45ºC 7.1 (5.9 ~ 10.2) 9.2 (5.0 ~ 10.2) 11.3 (6.8 ~ 14.0) 13.3 (7.6 ~ 16.5)

COP Ambient (db/wb) 7/6ºC 3.34 3.05 3.01 3.35

Capacity3 Nominal (min~max) (kW) Water (in/out) 47/55ºC 6.4 (5.3 ~ 9.3) - - -

COP Ambient (db/wb) 7/6ºC 2.71 - - -

Capacity4 Nominal (min~max) (kW) Water (in/out) 30/35ºC 6.5 (3.5 ~ 7.1) 6.9 (3.8 ~ 7.9) 8.4 (5.2 ~ 10.9) 9.3 (6.1 ~ 12.3)

COP Ambient (db/wb) -7/-8ºC 2.4 2.55 2.61 2.6

Capacity5 Nominal (min~max) (kW) Water (in/out) 40/45ºC 6.4 (3.4 ~ 6.9) 6.5 (3.7 ~ 7.7) 8.1 (5.0 ~ 10.5) 9.0 (5.8 ~ 12.0)

COP Ambient (db/wb) -7/-8ºC 2.01 2.22 2.28 2.21

Capacity6 Nominal (min~max) (kW) Water (in/out) 47/55ºC 6.2 (3.3 ~ 6.6) - - -

COP Ambient (db/wb) -7/-8ºC 1.82 - - -

Water Flow Nominal (min~max) (m³/hr) 1.29 (0.9 ~ 2.6) 1.92 (0.6 ~ 3.3) 2.4 (0.8 ~ 4.0) 2.4 (0.8 ~ 4.7)

Water Volume (minimum installation) (l) 28 38 46 56

Sound Pressure level dB(A) 49 49 51 52

Dimensions (mm)& Weight (kg)

Height 800 1480

Width 1250 1250

Depth 440 444

(1Ø/3Ø) Weight 110 / - 150 / - 155 / 160 159 / 164

Operating Range (ºC) Heating (-20 ~ +40)db

Power Supply1 Phase 1Ph 220-240V 50Hz

3 Phase - - 3Ph 380-415V 50Hz

Running Current (1Ø/3Ø) (A) (excludes pump) 7.5 / - 13.4 / - 16.6 / 7.7 17.6 / 8.2

Starting Current (A) < 10 < 10 < 10 < 10

Recommended Fuse Size (A) (1Ø/3Ø) 25 / - 25 / - 32 / 16 40 / 20

Heat

ing

Capa

city

For full technical details, refer to Technical Manual

Heating Manufacturer of the Year “ The judges felt Hitachi provided an excellent

submission, a great product and the way forward.”Hitachi’s Yutaki M Heat Pump

RHUE-A(V)HN(1) AF-RTU-01

Page 78: 2012 A5 Product Catalogue FULL (3)

Hitachi Yutaki heat pumps

The perfect heating and cooling solution for modern homes

Visit hitachiheating.comto find out more about our range of air source heat pumps

Hitachi Product Catalogue | 79

Page 79: 2012 A5 Product Catalogue FULL (3)

* Performed at the flow rate obtained during testing of the Yutaki-S at standard ambient rating conditions 7°C/6°C dB/wBPrice does not include room thermostat (see page 82)

For full technical details, refer to Technical Manual

Outdoor 1Ø RAS 2HVRN2 RAS 3HVRNME-AFOutdoor 3Ø - -

Outdoor Sound Pressure Level(Set Back) d(B)A

Cooling 45 (43) 42 ( 38)

Heating 47 50

Dimensions (mm)& Weight (kg)

Height 600 800Width 792 950Depth 300 370Weight 42 67

Operating Range (ºC)Cooling (10 ~ 46)ºC dbHeating (-20 ~ 35)ºC wb

Refrigerant Piping (mm) (in)Liquid 6.35(1/4) 9.52(3/8)Gas 12.7(1/2) 15.88(5/8)

Piping (m)Length 30 30

Lift (OU lower than IU) 30 / (20) 30 / (20)Pre-charged 30 30

Power Supply1 Phase 1Ph 220-240V 50Hz3 Phase - -

Starting Current (A) < 10 < 10

Running Current (1Ø/3Ø) (A)Cooling 5.2 8.2Heating 4.1 6.8

Recommended Fuse Size (A) 16 / - 25 / -

RAS-H(V)RNM(E)

AF-RTU-02

Yutaki-S

Outdoor Units

RAS-4/5H(V)RNME

RWM-FSN3E

Heating & Cooling RWM 2.0FSN3E RWM 3.0FSN3E

Heating only RWM 2.0HFSN3E RWM 3.0HFSN3E

Capacity Nominal (min~max) (kW) Water (in/out) 30/35ºC 5.1 (2.3 ~ 8.0) 7.5 (3.1 ~ 11.0)

COP Ambient (db/wb) 7/6ºC 5.02 4.55

Capacity Nominal (min~max) (kW) Water (in/out) 40/45ºC 4.7 (2.2 ~ 7.5) 7.1 (2.8 ~ 9.7)

COP Ambient (db/wb) 7/6ºC 3.51 3.47

Capacity Nominal (min~max) (kW) Water (in/out) 47/55ºC 4.2 (2.0 ~ 5.5) 6.2 (2.4 ~ 7.6)

COP Ambient (db/wb) 7/6ºC 2.63 2.65

Capacity Nominal (min~max) (kW) Water (in/out) */35ºC 4.0 (1.9 ~ 4.7) 6.4 (3.5 ~ 7.5)

COP Ambient (db/wb) -7/-8ºC 2.65 2.51

Capacity Nominal (min~max) (kW) Water (in/out) */45ºC 3.8 (1.8 ~ 4.4) 6.0 (3.3 ~ 6.9)

COP Ambient (db/wb) -7/-8ºC 2.10 2.33

Capacity Nominal (min~max) (kW) Water (in/out) */55ºC 3.0 (1.6 ~ 3.9) 5.3 (2.9 ~ 5.5)

COP Ambient (db/wb) -7/-8ºC 1.62 1.80

Capacity Nominal (min~max) (kW) Water (in/out) 12/7ºC 3.8 (1.8 ~ 5.4) 6.0 (2.5 ~ 6.9)

COP Ambient (db/wb) 35/-ºC 3.05 3.07

Capacity Nominal (min~max) (kW) Water (in/out) 23/18ºC 5.4 (2.6 ~ 7.5) 7.1 (3.0 ~ 8.0)

COP Ambient (db/wb) 35/-ºC 3.83 4.03

Water Flow Nominal (min~max) (m³/hr) 0.9 (0.5 ~ 2.2) 1.3 (0.9 ~ 2.6)Water Volume (minimum installation) (l) 28 28Sound Pressure level dB(A) 26 27

Dimensions (mm)& Weight (kg)

Height 890Width 520Depth 360Weight 55 56

Water Pipe Connection Inlet & Outlet G 1-1/4" (male) G 1-1/4" (male)Pump Input Power (watts) 75 100Electric Heater Power (kW) Steps 1.0/2.0/3.0 1.0/2.0/3.0Colour White (RAL 9016)

Power Supply1 Phase 1Ph 220-240V 50Hz3 Phase - -

Running Current (1Ø/3Ø) (A) Elec. Heater + Pump 13.3 13.5Recommended Fuse Size (1Ø/3Ø) (A) 20 20

Heat

ing

Capa

city

Cool

ing

Capa

city

Domestic Heating

Page 80: 2012 A5 Product Catalogue FULL (3)

Domestic Heating

Hitachi Product Catalogue | 81

RAS 4HVRNME-AF RAS 5HVRNME-AF RAS 6HVRNME-AF - -RAS 4HRNME-AF RAS 5HRNME-AF RAS 6HRNME-AF RAS 8HRNME-AF RAS 10HRNME-AF

44 (40) 46 (42) 48 (45) 52 (50) 55 (53)

52 55 55 54 561380 1650950 1100370 390

107 108 108 170 170(10 ~ 46)ºC db

(-20 ~ 35)ºC wb9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)* 12.70(1/2)*

15.88(5/8) 15.88(5/8) 15.88(5/8) 28.6(1/8)* 28.6(1/8)*30 30 30

30 / (20) 30 / (20) 30 / (20) 30 / (20) 30 / (20)30 30 30 30 30

1Ph 220-240V 50Hz - -3Ph 380-415V 50Hz

< 10 < 10 < 10 < 10 < 109.8 / 3.3 12.8 / 4.3 17.2 / 5.7 5.7 8.49.2 / 3.0 11.6 / 3.9 14.5 / 4.8 6.3 8.020 / 16 32 / 16 32 / 16 - / 16 - / 20

RWM 4.0FSN3E RWM 5.0FSN3E RWM 6.0FSN3E RWM 8.0FSN3E RWM 10.0FSN3E

RWM 4.0HFSN3E RWM 5.0HFSN3E RWM 6.0HFSN3E RWM 8.0HFSN3E RWM 10.0HFSN3E

9.8 (4.8 ~ 13.5) 12.0 (6.3 ~ 16.3) 14.0 (5.9 ~ 17.8) 19.6 (11.3 ~ 25.5) 24.0 (11.6 ~ 32.0)

4.47 4.36 4.11 4.45 4.41

9.2 (4.5 ~ 12.5) 11.3 (5.6 ~ 15.5) 13.3 (5.6 ~ 16.5) 18.4 (10.6 ~ 24.5) 22.6 (10.9 ~ 31.0)

3.42 3.16 3.01 3.43 3.40

8.1 (4.0 ~ 10.0) 10.1 (5.1 ~ 13.7) 12.6 (5.4 ~ 13.9) 16.2 (9.3 ~ 20.5) 20.2 (9.8 ~ 27.4)

2.59 2.60 2.47 2.70 2.67

7.6 (2.9 ~ 9.8) 9.0 (3.3 ~ 11.5) 9.4 (3.5 ~ 12.0) 14.8 (8.8 ~ 17.8) 18.0 (8.9 ~ 21.6)

2.42 2.40 2.34 2.63 2.61

7.1 (2.8 ~ 8.5) 8.3 (3.1 ~ 10.2) 8.7 (3.2 ~ 10.4) 14.2 (8.4 ~ 16.6) 16.6 (8.2 ~ 20.4)

2.14 1.92 1.81 2.17 2.16

5.9 (2.4 ~ 6.3) 7.7 (2.9 ~ 8.7) 7.9 (3.0 ~ 8.9) 11.8 (7.0 ~ 12.6) 15.4 (7.6 ~ 17.7)

1.55 1.55 1.46 1.73 1.72

7.2 (2.6 ~ 8.2) 9.2 (3.3 ~ 10.3) 10.5 (3.1 ~ 11.5) 14.4 (6.7 ~ 16.4) 18.4 (6.4 ~ 20.6)

3.06 3.03 2.61 3.53 3.12

10.0 (3.6 ~ 11.2) 12.9 (4.7 ~ 15.0) 15.0 (4.4 ~ 17.8) 20.0 (9.3 ~ 23.5) 24.5 (8.6 ~ 29.0)

3.88 4.02 3.50 4.43 3.57

1.7 (1.0 ~ 3.3) 2.1 (1.1 ~ 3.6) 2.4 (1.2 ~ 3.6) 3.4 (2.0 ~ 4.7) 4.1 (2.2 ~ 4.8)38 46 55 76 9228 28 28 29 29

890 890520 670360 360

59 61 61 81 85G 1-1/4" (male) G 1-1/4" (male) G 1-1/4" (male) G 1-1/4" (male) G 1-1/4" (male)

130 140 140 250 2602.0/4.0/6.0 2.0/4.0/6.0 2.0/4.0/6.0 3.0/6.0/9.0 3.0/6.0/9.0

White (RAL 9016)

1Ph 220-240V 50Hz or 3Ph 380-415V 50Hz- -

3Ph 380-415V 50Hz26.7 / 9.3 26.7 / 9.3 26.7 / 9.3 - / 14.1 - / 14.2

40 / 16 40 / 16 40 / 16 - / 20 - / 20

For full technical details, refer to Technical Manualhitachiheating.com Email: [email protected]: 01628 585 394

Page 81: 2012 A5 Product Catalogue FULL (3)

Domestic Heating

Yutaki Accessories

Model Code Range

Controller Pack Yutaki-M - (A(V)HN / A(V)HN-HM) Controller Pack - Controller + Room Thermostat (55ºC machine)

ATW-CPA-01 Controller CP60 Yutaki-M - (A(V)HN1) Controller Pack CP60 Controller + Room Thermostat (60ºC machine)

ATW-CPA-02 Yutaki-M - (A(V)HN1) Advanced Controller + Room Thermostat (60ºC machine) (check availability)

ATW-RTU-01 Yutaki-S (RWM - FSN3E) On/Off Thermostat (Receiver + Room Thermostat)

ATW-RTU-02 Yutaki-S (RWM - FSN3E) Intelligent Thermostat (Receiver + Room Thermostat)

ATW-RTU-03 Yutaki-S (RWM - FSN3E) 2nd Temp Thermostat, only RTU-02 (Only Room Thermostat)

RHM-EH01E Yutaki-M - (All Models) Hydraulic Module - Electric Heater inc Control Pack

RHM-BC01E Yutaki-M - (All Models) Hydraulic Module - Boiler Combination inc Control Pack

ATW-PK-01 Yutaki-M - (A(V)HN1) Pump Kit (Top-S 25/7)

ATW-PK2-01 Yutaki-M - (A(V)HN1) Pump Kit (Top-S 25/10)

ATW-PK3-01 Yutaki-M - (A(V)HN1) Pump Kit (Top-S 25-70/180)

Pump Kit A (small) Yutaki-M - (A(V)HN / A(V)HN-HM) Pump Kit A

Pump Kit B (big) Yutaki-M - (A(V)HN / A(V)HN-HM) Pump Kit B

ATW-WCV-01 Yutaki-M - (All Models) Water Check Valve

WEH-6E Yutaki-M - (All Models) Both 1Ø & 3Ø Electric Heater 6kW - (2/4/6kW stages)

ATW-HSK-01 Yutaki-M/S Hydraulic Separator

ATW-3WV-01 Yutaki-M/S 3-Way Valve

ATW-2KT-01 Yutaki-M/S 2nd Zone Temperature Kit

ATW-AQT-01 Yutaki-M/S Aquastat

ATW-WTS-02Y Yutaki-M/S Water Temperature Sensor for Hot Water Tank (included with HAPE Tank)

DBS-26 Yutaki-M/S Drain Boss Kit

ATW-MVM-01 Yutaki-S (RWM - FSN3E) Mixing valve motor

ATW-DPK-01 Yutaki-S (RWM - 2.0~6.0FSN3E) Drain Pan Kit for RWM

ATW-DPK-02 Yutaki-S (RWM - 8 ~ 10FSN3E) Drain Pan Kit for RWM

ATW-AOS-01 Yutaki-S (RWM - FSN3E) Auxiliary output signal box

ATW-20S-01 Yutaki-S (RWM - FSN3E) 2nd Outdoor Temperature Sensor

ATW-WTS-02 Yutaki-S (RWM - FSN3E) Water Temperature Sensor (2nd Temp control, boiler combination)

ATW-SPS-01 Yutaki-S (RWM - FSN3E) Swimming Pool Sensor

DHWT200E - 2.5H1E Yutaki-M/S 200L Enamelled Tank inc. 2.5kW electric heater

DHWT300E - 2.5H1E Yutaki-M/S 300L Enamelled Tank inc. 2.5kW electric heater

DHWT200S - 2.5H1E Yutaki-M/S 200L Stainless Steel Tank inc. 2.5kW electric heater

DHWT300S - 2.5H1E Yutaki-M/S 300L Stainless Steel Tank inc. 2.5kW electric heater

DHWT-CP-01 Yutaki-M/S Permanent cathode protection for enamelled tank 200L

DHWT-CP-02 Yutaki-M/S Permanent cathode protection for stainless steel tank 200L

DHWT-CP-03 Yutaki-M/S Permanent cathode protection for enamelled tank 300L

DHWT-CP-04 Yutaki-M/S Permanent cathode protection for stainless steel tank 300L

DHWT-SWG-01 Yutaki-M/S Safety valves

For full technical details, refer to Technical Manual

1

2

3

4

5

6

7

8

9

10

11

12

13

15

11

16

17

18

14

Page 82: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 83

Yutaki Accessories

Domestic Heating

1 32 4 5

6 7 8 9 10

15 16 17 18

11 12 13 14

For full technical details, refer to Technical Manualhitachiheating.com Email: [email protected]: 01628 585 394

Page 83: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Samurai Chillers

Hitachi Samurai Chillers offer world-renowned reliability thanks to Hitachi’s twin screw compressors.

Unlike some competitors, Hitachi manufactures the compressors and was, in fact, the world’s first

supplier of screw chiller units.

All Samurai Chillers

110~1030kW - available with heat recovery option – and Heat Pump models from 120~600kW

energy saving over step control

Hitachi uses high technology to achieve the lowest sound. The adoption of DC Inverter twin blade fans, rather than four, achieves a reduction of noise level. Low noise and super low noise models are available

independent of cooling load

maximum starting current

reliable with very low noise and vibration

Due to the meticulous design of each and every component, it is possible to achieve exceptionally high cooling capacity values per square metre.

Hydraulic Module Option - Single and Dual Pump Models

Hitachi Hydraulic modules are a compact design integrated inside the Chiller unit. They are assembled with all interconnecting piping and wiring during manufacture ready for installation.

Available for Air-Cooled Cooling Only RCU2E(40~80)AG2 and Air Cooled Heat Pump RHU2E(40~80)AG2 models. Available with single or dual pumps and with or without a buffer tank.

Other options available, please contact your local sales office.

Page 84: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 85

Samurai Air Cooled Cooling OnlyRCU2E 40~400AG2

Air Cooled Heat PumpRHU2E 40~240AG2

Water CooledRCUE 40~240WG2

Condenserless Cooling OnlyRCUE 40~120CLG2

Nominal Cooling Capacity (kW) 112 ~ 1030 106 ~ 585 134 ~ 696 120 ~ 360

Nominal Heating Capacity (kW) - 110 ~ 556 161 ~ 824 -

Refrigerant R407C R407C R407C R407C

Compressor Type Screw Screw Screw Screw

Operating Range (Cooling) (-15ºC ~ 46ºC)db (-15ºC ~ 46ºC)db - -

Operating Range (Heating) - (-15ºC ~ 15.5ºC)db - -

No. Circuits 1 ~ 5 1 ~ 3 1 ~ 3 1 ~ 2

Page 85: 2012 A5 Product Catalogue FULL (3)

Samurai Chillers

Air Cooled Cooling Only

RHU2E 40AG2

RHU2E 50AG2

RHU2E 60AG2

RHU2E 70AG2

RHU2E 80AG2

RHU2E 100AG2

RHU2E 120AG2

RHU2E 140AG2

RHU2E 160AG2

RHU2E 180AG2

RHU2E 210AG2

RHU2E 240AG2

Cooling Capacity1 kW 106 123 148 169 195 246 296 338 390 444 507 585Heating Capacity2 kW 110 127 152 185 185 254 304 370 370 456 555 555Power Input (Cooling) kW 37.9 42.7 52 60 70 85.4 104 120 140 156 180 210Power Input (Heating) kW 40.7 44.5 54 68 68 89 108 136 136 162 204 204EER 2.8 2.88 2.85 2.82 2.79 2.88 2.85 2.82 2.79 2.85 2.82 2.79COP 2.7 2.85 2.81 2.72 2.72 2.85 2.81 2.72 2.72 2.81 2.72 2.72ESEER 3.36 3.45 3.42 3.38 3.34 3.45 3.42 3.38 3.34 3.42 3.38 3.34

Sound Power Level (Std/LN/SLN)

dB(A)82/80/78 83/81/79 84/82/80 85/83/81 85/83/81 86/84/82 87/85/83 88/86/84 88/86/84 89/87/85 91/89/87 91/89/87

Sound Pressure Level (Std/LN/SLN)3

dB(A)52/50/48 53/51/49 54/52/50 55/53/51 55/53/51 55/53/51 56/54/52 57/55/53 57/55/53 57/55/53 58/56/54 58/56/54

Height mm 2430Width mm 1900Depth mm 2190 2790 4090 5290 5990 7790Net Weight kg 1550 1600 1670 1880 1950 3050 3250 3670 3780 4780 5440 5650

Capacity Control- Continuous Capacity Control% 15 ~ 100

Number of Circuits - 1 1 1 1 1 2 2 2 2 3 3 3

Water Pipe Connectionin 3” Victaulic (1 x Inlet / 1 x Outlet) per Circuitin - Common Water Pipe Connection Option available

Leaving Water Outlet Temperature (Cool)

°C 5 ~ 15 (-10 option)

Leaving Water Outlet Temperature (Heat)

°C 35 ~ 55

Ambient Temperature °C -15 ~ 46 Cooling / -10 ~ 15.5wb Heating

Air Cooled Heat Pump

NOTES: Please refer to notes 1 and 3

RCU2E 40AG2

RCU2E 50AG2

RCU2E 60AG2

RCU2E 70AG2

RCU2E 80AG2

RCU2E 100AG2

RCU2E 120AG2

RCU2E 140AG2

RCU2E 160AG2

RCU2E 180AG2

RCU2E 210AG2

RCU2E 240AG2

RCU2E 280AG2

RCU2E 320AG2

RCU2E 350AG2

RCU2E 400AG2

Cooling Capacity1 kW 112 130 156 178 206 260 312 356 412 468 534 618 712 824 890 1030Power Input kW 38.6 44.7 53 61 70 89.4 106 122 140 159 183 210 244 280 305 350EER 2.9 2.91 2.94 2.92 2.94 2.91 2.94 2.92 2.94 2.94 2.92 2.94 2.92 2.94 2.92 2.94ESEER 3.48 3.49 3.52 3.5 3.52 3.49 3.52 3.5 3.52 3.52 3.5 3.52 3.5 3.52 3.5 3.52

Sound Power Level (Std/LN/SLN)

dB(A)82/80/78 83/81/79 84/82/80 85/83/81 85/83/81 86/84/82 87/85/83 88/86/84 88/86/84 89/87/85 91/89/87 91/89/87 92/90/88 92/90/88 94/92/90 94/92/90

Sound Pressure Level (Std/LN/SLN)3

dB(A)52/50/48 53/51/49 54/52/50 55/53/51 55/53/51 55/53/51 56/54/52 57/55/53 57/55/53 57/55/53 58/56/54 58/56/54 59/57/55 59/57/55 60/58/56 60/58/56

Height mm 2430Width mm 1900Depth mm 2190 2790 4090 5290 5990 7790 10290 12790Net Weight kg 1430 1470 1560 1760 1820 2830 3000 3420 3550 4450 5070 5250 6750 7000 8450 8750Capacity Control % 15 ~ 100Number of Circuits - 1 1 1 1 1 2 2 2 2 3 3 3 4 4 5 5

Water Pipe Connection

in 3” Victaulic (1 x Inlet / 1 x Outlet) per Circuitin - Common Water Pipe Connection Option available

Leaving Water Outlet Temperature

°C 5 ~ 15 (-10 option)

Ambient Temperature °C -15 ~ 46

NOTES: Please refer to notes 1, 2 and 3

Page 86: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

Hitachi Product Catalogue | 87

Samurai Chillers

Water Cooled

RCUE 40WG2

RCUE 50WG2

RCUE 60WG2

RCUE 80WG2

RCUE 100WG2

RCUE 120WG2

RCUE 150WG2

RCUE 180WG2

RCUE 200WG2

RCUE 240WG2

Cooling Capacity4 kW 134 160 194 232 320 388 445 525 600 696Heating Capacity5 kW 161.1 192.3 233.9 274.7 384.7 467.9 526.9 621.9 719.5 824.2Power Input (Cooling)4 kW 33.5 40 49.1 54.5 80 98.2 104.5 123.5 148.5 163.5Power Input (Heating)5 kW 39.8 47.5 58.3 64.7 95 116.6 124.1 146.7 176.4 194.2EER 4.0 4.0 4.0 4.3 4.0 4.0 4.3 4.3 4.0 4.3COP 4.0 4.0 4.0 4.2 4.0 4.0 4.2 4.2 4.1 4.2ESEER 4.52 4.52 4.46 4.81 4.52 4.46 4.83 4.82 4.55 4.82Sound Power Level dB(A) 83 84 86 86 88 90 90 91 92 93Sound Pressure Level dB(A) 68 69 71 71 72 74 74 75 76 77Height mm 1520 1700 1580Width mm 1105Depth mm 850 1465 2350Net Weight kg 750 765 830 950 1570 1670 1770 2500 2580 2670

Capacity Control- Continuous Capacity Control% 15 ~ 100

Number of Circuits - 1 1 1 1 2 2 2 3 3 3

Water Pipe Connection (Evaporator)

in 3” Victaulic (1 x Inlet / 1 x Outlet) 3” Victaulic (3 x Inlet / 3 x Outlet)in - 5” Victaulic (1 x Inlet / 1 x Outlet)

Water Pipe Connection (Condenser)

in 3” Victaulic (1 x Inlet / 1 x Outlet) 3” Victaulic (3 x Inlet / 3 x Outlet)in - 5” Victaulic (1 x Inlet / 1 x Outlet)

Leaving Water Outlet Temperature (Cool) °C 5 ~ 15 (-10 option)

Leaving Water Outlet Temperature (Heat) °C 25 ~ 55

Condenser Water Outlet Temprature7 °C 22 ~ 45 (55* option)

RCUE 40CLG2

RCUE 50CLG2

RCUE 60CLG2

RCUE 80CLG2

RCUE 100CLG2

RCUE 120CLG2

Cooling Capacity6 kW 120 145 180 240 290 360Power Input kW 34.4 42.4 52.1 68.8 84.8 104.2EER 3.5 3.4 3.5 3.5 3.4 3.5ESEER 4.32 4.32 4.28 4.32 4.23 4.28Sound Power Level dB(A) 83 84 86 86 88 90Sound Pressure Level dB(A) 68 69 71 71 72 74Height mm 1520 1720Width mm 1045 1104Depth mm 885 1471Net Weight kg 630 680 730 1200 1310 1380

Capacity Control- Continuous Capacity Control% 15 ~ 100

Number of Circuits - 1 1 1 2 2 2Water Pipe Connection (Evaporator) in 3” Victaulic (1 x Inlet / 1 x Outlet)

Leaving Water Outlet Temperature °C 5 ~ 15 (-10 option)

Condensing Temperature °C 30 ~ 65

Condenserless Cooling Only

NOTES: Please refer to notes 4 and 5. 7 ( ) is in case of high condensing option and heat pump operation option.

NOTES: Please refer to note 6

NOTES:

1. The nominal cooling capacities are based on the European Standard EN14511.

Chilled Water Inlet / Outlet Temperature: 12 / 7°C Condenser Inlet Air Temperature: 35°C

2. The nominal heating capacities are based on the European Standard EN14511.

Heated Water Inlet / Outlet Temperature: 40 / 45°C Evaporator Air Inlet Temperature: 6°C wb

3. Sound Pressure level measured at 10m

4. The nominal cooling capacities are based on the European Standard EN12055.

Chilled Water Inlet / Outlet Temperature: 12 / 7°C Cooling Water Inlet / Outlet Temperature: 30 / 35°C

5. The nominal heating capacities are only for Heat Pump Operation Option and based on following conditions.

Chilled Water Inlet / Outlet Temperature: 12 / 7°C Hot Water (Condenser) Inlet / Outlet Temperature: 40 / 45°C

6. The nominal cooling capacities are based on the following conditions.

Chilled Water Inlet / Outlet Temperature: 12 / 7°C Condensing Temperature: 45°C

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 87: 2012 A5 Product Catalogue FULL (3)

Features and Benefits

Control Systems and Accessories

H-LINK II

H-LINK II across the entire Hitachi product range means you can use Hitachi System Free controls for any mix of products.

CS Net Web

Hitachi’s CS Net Web is a standalone control system that allows users to fully monitor and control their air conditioning from anywhere with web access. Single and multiple sites can be monitored from one central point and the user can ascertain the system performance at all times.

CS Net Web can control up to 512 indoor units and up to 64 outdoor units connected to the H-LINK communication system.

Optional touchscreen

Hitachi’s touchscreen allows intuitive control of up to four CS Net Web central controllers. It can be fixed to either a wall or table using the supplied mounting bracket.

BMS Interfaces

BMS interfacing options are compatible with the Utopia, Set Free and Samurai Chiller ranges allowing the connection of Hitachi H-LINK air conditioning units to building management systems using Modbus, BacNet, KNX and LonWorks® protocols.

ModBusInterface to allow a ModBus compatible building management system to control and monitor up to 32 H-LINK compatible indoor units, or up to eight Samurai Chillers via a RS485 connection. Up to eight controllers can be connected to one H-LINK communications circuit.

KNXInterface to allow a KNX compatible building management system to control and monitor up to 16 H-LINK compatible indoor units. This unit is an accessory for the CS Net Web central controller and connects to the BMS system via a KNX-TP1 type connection.

HARC BX (A/B) LonWorks®

Interface to allow a LonWorks® compatible building management system to control and monitor up to 64 (option A) or 32 (option B) H-LINK compatible indoor units.

BMS interface HARC70-CE1/OP LonWorks®

Interface to allow integration of Hitachi H-LINK and LonWorks® BMS systems. Two options are available dependent on the level of control required.

BACNetInterface to allow a BACNet compatible building management system to control and monitor up to 64 H-LINK compatible indoor units via the BACNet/IP protocol.

Page 88: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 89

Page 89: 2012 A5 Product Catalogue FULL (3)

Control Systems and Accessories

Individual Controls

Group Controls

RAC Controls

SPX-RCK3 Wired Remote Controller - WX8, FH6, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8

SPX-RCK2 Wireless Remote Controller & Receiver Kit - RAD-NH7A

SPX-WKT1 Wired Remote Controller + 7 Day Timer - WX8, FH6, YH7, YH5A, NH5A, NH7A, FX8, NX2, QH8

SPX-DST1 Optional Distributor Kit for SPK-WKT1 (centralised control of up to 13 indoor units)

SPX-WDST8M Optional wiring kit for SPX-WKT1 & SPX-DST1

PSC-6RAD H-LINK Adapter connects RAC models: WX8, FH6, YH7, YH5A, NH5A, NH7A, FX8, NX2 and QH8 to H-LINK

System Free Controls

PC-ART Std. Wired Remote Controller (inc 7 Day Time Clock) (System Free Indoor Units)

PC-ARF Wired LED Controller with advanced graphical interface (inc 7 Day Time Clock) (System Free Indoor Units)

PC-ARH Simple Wired Remote Controller - (System Free Indoor Units)

PC-LH3A Wireless Remote Controller - Receiver kit required (inc. with RPK-FSN2M)

PC-ALHN Receiver Kit panel mounted (RCI-FSN3E)

PC-ALHD Receiver Kit panel mounted (RCD-FSN3E)

PC-ALHC Receiver Kit panel mounted (RCIM-FSN3E)

PC-ALHZ Receiver Kit wall mounted (All System Free Indoor Units)

Group Controls

PSC-A64GT Touchscreen Central Controller (64 Groups, 160 Units - System Free)

PSC-A64S Central Controller (64 Groups, 160 Units - System Free)

CSC 5S Central Controller - (up to eight Samurai Chillers)

PSC-A1T 7 Day Timer

CS Net Web (v3.0) Web based Control, Stand alone or with Touchscreen below (64 outdoor units, 512 indoor units)

TS002 Touchscreen for CS Net Web

PC-A1IO Control/Monitor 3rd party equipment via CS Net Web

PSC-5HR H-LINK Relay - extend H-LINK wiring up to maximum 1,000m

BMS Interface Controls

HC-A32MB ModBus Interface, control/monitor 32 System Free indoor units or 8 Samurai Chillers

HARC-BX (A/B) LonWorks® Interface, control/monitor 64(A) or 32(B) System Free indoor units

HARC-70CE1 (OP) LonWorks® Interface, control/monitor up to 4 Samurai Chillers

HC-A16KNX KNX Interface, control/monitor 16 System Free indoor units

HC-A64BNP BACNet Interface, control/monitor 64 System Free indoor units

SPX-RCK3

SPX-WKT1

SPX-RCK2

PC-ART

PCS-A64GT

PC-ARH

PC-ARF

PSC-A64S CS Net Web

PSC-A1T

Touchscreen

BMS Interface Controls

For full technical details, refer to Technical Manual

Page 90: 2012 A5 Product Catalogue FULL (3)

Control Systems and Accessories

Hitachi Product Catalogue | 91

For full technical details, refer to Technical Manual

S Y S T E MFREE

Accessories

PCC1A Optional Function Connector Cables (pack of 5) - Utopia and Set Free

THM-R2AE Remote Sensor

PDF-23C3 Side Duct Connection Flange (RCI 1.0~3.0FSN3E)

PDF-46C3 Side Duct Connection Flange (RCI 4.0~6.0FSN3E)

PD-75 Fresh Air Intake Kit, 75mm dia (RCI 1.0~6.0FSN3E)

PI 23LS5 Cassette 3-Way outlet kit

DBS 26 Drain Boss Kit (All Outdoor Units except below)

DBS 12L Drain Boss Kit (RAS 2.0 ~ 2.5HVRN2 + RAS 3.0HVRNS2)

DBS-TP10A Drain Boss Kit (RAS-FSXN)

DU M1E Drain Pump Kit (RPIM-FSN2E)

PCC1A

DBS 26

PD-75

DBS 12L

THM-R2AE

DU M1E

Accessories

Pipe Kits (Utopia ES, IVX, Centrifugal)

TE-03N Twin Pipe Kit (3HP System)

TE-04N Twin Pipe Kit (4HP System)

TE-56N Twin Pipe Kit (5 & 6HP System)

TE-08N Twin Pipe Kit (8HP System)

TE-10N Twin Pipe Kit (10 & 12HP System)

TRE-06N Triple Pipe Kit (4 ~ 6HP System)

TRE-810N Triple Pipe Kit (8 ~ 12HP System)

QE-810N Quad Pipe Kit (8 ~ 12HP System)

E-102SN2 Piping Kit (Only use with 8 ~ 12HP IVX)

E-162SN2 Piping Kit (Only use with 8 ~ 12HP IVX)

Pipe Kits (Set Free - Mini, Side Flow, Modular)

E-102SN2 Piping Kit (Only use with 8 ~ 12HP IVX)

E-162SN2 Piping Kit (Only use with 8 ~ 12HP IVX)

E 242SN2 Pipe Kit (2-pipe)

E 302SN2 Pipe Kit (2-pipe)

E 52XN2 Pipe Kit (3-pipe)

E 102XN2 Pipe Kit (3-pipe)

E 162XN2 Pipe Kit (3-pipe)

E 202XN2 Pipe Kit (3-pipe)

E 242XN2 Pipe Kit (3-pipe)

E 322XN2 Pipe Kit (3-pipe)

MH 84AN Pipe Kit (2-pipe header)

MH 108AN Pipe Kit (2-pipe header)

MH 108XN Pipe Kit (3-pipe header)

MC 20AN Modular Set Free 2-pipe Branch Kit (RAS 20~24FSXN)

MC 21AN Modular Set Free 2-pipe Branch Kit (RAS 26~36FSXN)

MC 30AN Modular Set Free 2-pipe Branch Kit (RAS 28~54FSXN)

MC 20XN Modular Set Free 3-pipe Branch Kit (RAS 20~24FSXN)

MC 21XN Modular Set Free 3-pipe Branch Kit (RAS 26~36FSXN)

MC 30XN Modular Set Free 3-pipe Branch Kit (RAS 28~54FSXN)

Pipe Kits

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 91: 2012 A5 Product Catalogue FULL (3)

For full details, refer to Technical Manual

Helping YouDirect Sales (UK)

E: [email protected]

T: 01628 585 394

Spares

E: [email protected]

T: 01628 585 394

hitachiairco

n.com/spareparts

Technical (UK)T: 01628 585 393

Technical and Service Manuals available athitachiaircon.com

Proactively meeting the expectations of our customers through continuous innovation

Download our latest

selection (HiToolkit)

software at

hitachiaircon.com

Page 92: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 93

Direct Sales (Ireland)E: [email protected]: 00 353 1216 4406

ApplicationsE: [email protected]

T: 01628 585 394

TrainingE: [email protected]: 01628 585 394

WarrantyE: [email protected]

T: 01628 585 393

hitachiaircon.com/warranty

24-hour alarm codesT: 01628 585 393 (option 2) or visit hitachiaircon.com to download our new alarm codes App

Technical (Ireland)

T: 00 353 1296 8065

Technical and Service

Manuals available at

hitachiaircon.com

Page 93: 2012 A5 Product Catalogue FULL (3)

Hitachi’s Training Centre

Helping you increase your technical and product knowledgeHitachi offer high-quality training courses in its aircademy training centre based at Hitachi Europe Headquarters in Maidenhead, Berkshire. This newly-refurbished centre is dedicated to excellence and a wide range of Hitachi air conditioning and refrigeration products are displayed.

The equipment is fully operational and used extensively throughout all training courses allowing Hitachi to offer practical, hands-on experience to attendees.

All training is given by highly-skilled engineers with vast industry experience and an in-depth knowledge of Hitachi products. If you have any specific training requests please contact us and our engineers will be happy to tailor a course to suit your needs.Contact [email protected]

Page 94: 2012 A5 Product Catalogue FULL (3)

Product training coursesHitachi’s one-day product-specific training courses are provided FREE OF CHARGE.

Lunch included.

Morning 09.45-12.45 Afternoon 13.30-17.00

Mechanical and electrical coursesMechanical and electrical training courses, such as basic refrigeration and air conditioning, safe handling of refrigerants, IEE wiring regulations, electrical inspection and essential electrics are available with an external partner upon request. All courses provide CITB or City and Guilds qualifications upon completion.

set up

up demonstration

connecting to LAN

CS Net Web for the Field Engineer

design and application

and control wiring

and operation

(Yutaki S)

Yutaki Air to Water Heat Pump for the Field Engineer

demonstration

Set Free and Utopia Selection and Design

Samurai Selection and Design

and installation

and control wiring

and operation

and operation

and system set up

and system interrogation

interfacing overview

Samurai Chillers for the Field Engineer

Set Free VRF and Utopia Inverter Splits for the Field Engineer

design and installation

control wiring

and operation

interfacing overview

Room Air Conditioners for the Field Engineer

pipe work design and installation

and control wiring

system interrogation

interfacing overview

and operation

Hitachi Price List | 95

ContactT: 01628 585394

E: [email protected]

F: 01628 585500

Page 95: 2012 A5 Product Catalogue FULL (3)

Every precaution has been taken during the design and manufacture of Hitachi Air Conditioning equipment to ensure the products conform to the highest standards. In the event of a warranty fault the owner should advise the original installer. The following sets out the current Hitachi Air Conditioning Europe SAS warranty policy.

For all RAC products the warranty period shall be for 36 months (3 years) from date of invoice.

For all Utopia and Set Free the warranty period shall be 60 months (5 years) from date of invoice**.

For all Samurai Chillers the warranty period shall be 36 months (3 Years) from the date of invoice.

For all Central Control Systems the warranty period shall be 36 months (3 years) from the date of invoice.

®

period for the applicable indoor unit.

For all spare parts, the warranty period shall be 12 months parts only.

Warranty

All components requested to be returned should be sent to Hitachi Air Conditioning Europe SAS (Warranty Department) Whitebrook Park, Lower Cookham Road, Maidenhead, SL6 8YA clearly marked with the Warranty number. Components returned without a valid Warranty number will not be accepted.

Within the above specified time periods, all products are guaranteed against manufacturing faults in workmanship and material. The faulty component will be replaced free of charge provided the correct procedures are complied with and a labour contribution can be claimed during the first 3 years***, the amounts of which are laid out on next page.

The warranty policies are subject to the following conditions.

The Hitachi Air Conditioning Europe SAS equipment is installed using the correct working practices, and installed within the parameters set out in the technical manuals for each unit, and maintained regularly (minimum of every 6 months, site dependant, by a qualified installer) in accordance with the manufacturer’s recommendations.

Placing a claim Place your claim online

Contact the warranty department on 01628 585 393, and ask for your secure login to be set up and place your warranty claim online at hitachiaircon.com/warranty

You can then track the progress of your claim “live” online, and gain access to tracking and despatch details and receive email notification of your warranty progression.

If any of the information is not available at the time of claim, then the part can be ordered via an official purchase order and a credit arranged retrospectively, when all the information is available. (This must be within 60 days of the original date of failure).

All warranty claims must be made within 60 days of failure. Any claim submitted after the 60 day period WILL NOT be considered for approval.

Parts should be held by the customer for a period of 30 days during which time if required, Hitachi Air Conditioning Europe SAS can request the return of the parts at our cost for inspection and a RMA number will be issued. If it is deemed to have failed “out of warranty” the part will be invoiced to the customer at our standard spare parts rate.

Repeat warranty requests will be subject to Hitachi Air Conditioning Europe SAS investigation and possible site visit. An official purchase order will be required to purchase the part, pending a decision on the validity of the claim. All parts will be inspected within 14 days, and a credit issued if the warranty is accepted. For warranty claims rejected following inspection, the part will be returned and invoiced to the customer at our standard spare

Normal wear and tear is excluded.

Any claim not submitted in accordance with Hitachi Air Conditioning Europe SAS procedures WILL NOT be considered for credit.

* Approved combinations only.

** Subject to Hitachi Air Conditioning Europe SAS assisting with the commissioning, and commissioning reports being logged with ourselves. Failure to comply will result in the warranty reverting to 36 months (3 years) parts and labour contribution.

Page 96: 2012 A5 Product Catalogue FULL (3)

For a wallet-sized list of alarm codes for RAC, Set Free VRF and Utopia Split Systems

Contact [email protected] to request a copy

Or visit hitachiaircon.com to download our new alarm codes App

AndroidScan this QR Code using your Android phone to download our new alarm codes App

iPhone - iOSScan this QR Code using your iPhone - iOS phone to download our new alarm codes App

Hitachi Product Catalogue | 97

Alarm Codes

Page 97: 2012 A5 Product Catalogue FULL (3)

Alarm Codes for

Indoor unit faults

Flashing TIMER lamp

Main cause

1 time the heating mode or it is too high in the cooling mode

2 times

3 times

4 times

5 times

6 times Drain high level water alarm

7 times Drain pump forced operation

8 times Louver defective

9 times

10 times Fan motor overload

11 times High voltage generator fault

12 times

13 times

17 times

18 times Cleaning unit defect

19 times Failure of peltier device

Flashing CLEAN lamp

Main cause

1 time Front cover is open

4 times Failure of the cleaning unit motor or detection switch

Flashing MONITOR lamp

Main cause

1 time Front cover is open

4 times

Outdoor unit faults

Flashing LD 301 Main cause

1 time Normal operation

2 times Compressor overload

3 times Low compressor rotation

4 times Compressor switching failure

5 times

6 times Compressor over temperature alarm

7 times Faulty thermistor (check LD 303 to identify which one)

8 times

9 timesCommunication alarm

10 times

12 times Fan alarm

13 times Eeprom error

14 times

Flashing LD 304 Main cause

1 time Communication error

Flashing LD 303 Main cause

1 time

2 times Defrost thermistor

3 times

4 times

5 times Suction line thermistor (Unit 1)

6 times

7 times Suction line thermistor (Unit 2)

8 times

9 times Suction line thermistor (Unit 3)

10 times

11 times Suction line thermistor (Unit 4)

12 times

13 times Suction line thermistor (Unit 5)

Alarm Codes

Page 98: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 99

For full technical details, refer to Technical Manual

Alarm Codes for

remote control switch.

service provider.

Alarm Code

Alarm Code

Alternate indication every second

Indoor unit number

Model code

Number of indoor units connected

Model Code

Indication Model

H Heat Pump

P Inverter

F Multi

C Cooling Unit

E Others

L KPI

Code No. Category Type of Abnormality Main cause

01 Indoor unit Protection device activation (float switch) Float switch activation (high water level in drain pan. Blockage in drain pipe, float switch activated or drain pump faulty)

02 Outdoor unit Protection device activationHP switch activation (pipe blocked, excess refrigerant, non condensable present). Phase loss or incorrect rotation (Utopia only), float switch activation or MT open circuit (Centrifugal unit only)

03 Transmission Abnormality between indoor and outdoor communication

Incorrect wiring, loose terminals, disconnect cable, blown fuse, outdoor unit switched off. Incorrect address setting

04 Transmission Abnormality between inverter PCB and outdoor PCB

Inverter PCB - Outdoor PCB transmission fault (loose connector, broken cable, blown fuse)

Transmission Abnormality between fan controller and outdoor PCB

Fan controller - Outdoor PCB transmission fault (loose connector, broken cable, blown fuse)

05 Power phase Abnormality in the power phases Incorrect power supply, inverted phase connection, open phase

06 Voltage Abnormal inverter voltage Abnormal inverter controller voltage

Outdoor voltage drop, insufficient power. Capacitor or electronic problem on inverter compressor

Voltage Abnormal inverter voltage Abnormal fan controller voltage

Outdoor voltage drop, insufficient power. Capacitor or electronic problem on fan motor

07 Refrigerant Cycle

Drop in discharge gas superheatExcessive refrigerant charge, thermistor fault, incorrect wiring, incorrect pipe connection, expansion valve locked in open position (connector disconnected).

08 Refrigerant Cycle

Increase in discharge gas temperature Insufficient refrigerant charge, blocked pipe, thermistor fault, incorrect wiring, incorrect pipe connection, expansion valve locked in closed position (connector disconnected)

09 Outdoor unit Tripping of protection device Fan motor failure

0A Transmission Abnormality between outdoor and indoor units Incorrect wiring, broken cable, loose terminals

Outdoor unit Incorrect outdoor unit address setting. Main unit of the outdoor unit incorrectly set

Duplicate address setting of outdoor units (secondary units) in the same refrigerant cycle system

0C Outdoor unit Main unit of the outdoor unit incorrectly set Two (or more) outdoor units defined as the “main unit” in the same refrigerant cycle system

11 Indoor unit Air inlet thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

12 Indoor unit Air outlet thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

13 Indoor unit Frost protection thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

14 Indoor unit Gas pipe thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

Alarm Codes for

Alarm Codes

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 99: 2012 A5 Product Catalogue FULL (3)

Alarm Codes

For full technical details, refer to Technical Manual

Alarm Codes for RAS FSNM

Alarm Codes for

Continued...

Code No. Category Type of Abnormality Main cause

15 Indoor unit Outdoor air thermistor (KPI) Incorrect wiring, disconnected wiring, broken cable, short circuit

16 Indoor unit Remote thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

17 Indoor unit Remote controller thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

19 Fan motor Indoor fan protection device activation Fan motor overheating, locking

20 Outdoor unit Discharge gas thermistor at top of compressor (Utopia)

Incorrect wiring, disconnected wiring, broken cable, short circuit

21 Outdoor unit High pressure sensor Incorrect wiring, disconnected wiring, broken cable, short circuit

22 Outdoor unit Outdoor air thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

23 Outdoor unit Discharge gas thermistor at top of compressor (VRF)

Incorrect wiring, disconnected wiring, broken cable, short circuit

24 Outdoor unit Heat exchanger liquid pipe thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

25 Outdoor unit Heat exchanger gas pipe thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

26 Outdoor unit Suction gas thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

29 Outdoor unit Low pressure sensor Incorrect wiring, disconnected wiring, broken cable, short circuit

31 Outdoor unit Incorrect capacity setting on outdoor and indoor units

Combination capacity incorrectly set. Excessive or insufficient total indoor unit capacity.

32 SystemLoss of communication with 1 indoor unit (Multi system)

Loss of power, Incorrect wiring, loose terminals, disconnect cable, blown fuse, outdoor unit switched off. Incorrect address setting

35 Indoor unit Indoor unit no. incorrectly set Indoor unit no. duplicated in same refrigeration cycle

38 Outdoor unit Abnormality in the control circuit for outdoor unit protection

Protection detection device fault (incorrect wiring of outdoor PCB)

39 Compressor Abnormal operation current in constant speed compressor

Over current, blown fuse, current sensor fault, instant power failure, voltage drop, abnormal power supply or faulty compressor

3A Outdoor unit Abnormal outdoor unit capacity Outdoor unit capacity >54 HP

Outdoor unit Voltage or combination of outdoor unit models incorrectly set

Voltage or combination of secondary and main units incorrectly set

Outdoor unit Abnormal transmission between the main unit and the secondary units

Incorrect wiring, disconnected wiring, broken cable, PCB fault

41 Refrigerant Cycle

Cooling overload (possible activation of high pressure device)

O.U. pipe thermistor temp. is higher than 55 ºC and the compressor top temp. is higher than 95 ºC, O.U. protection device is activated

42 Refrigerant Cycle

Heating overload (high-pressure device may be activated)

If I.U. freeze protection thermistor temp. is higher than 55 and compressor top temp. is higher than 95

44 Refrigerant Cycle

Low-pressure increase protection device activation

Overload during cooling, high temperature with heating, locked expansion valve (loose connector)

45 Refrigerant Cycle

High pressure increase protection device activation

Blocked condenser, pipe blocked, excess refrigerant, non condensable present

47 Refrigerant Cycle

Low-pressure decrease protection device activation (vacuum protection)

"Insufficient refrigerant, refrigerant pipes blocked, expansion valve locked in closed position (VRF). Stoppage due to excessive decrease of evaporating temperature (Temp < -35 ºC) is activated 3 times in one hour, motor locked in heating mode.“

Page 100: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 101

Alarm Codes

For full technical details, refer to Technical Manual

Alarm Codes for RAS FSNM

Alarm Codes for

Continued...

Code No. Category Type of Abnormality Main cause

48 Inverter compressor

Inverter over current protection device activation

Overload, compressor fault

51 Inverter compressor

Abnormal inverter current sensor Current sensor fault

53 Inverter compressor

Inverter error signal detection Controller IC error signal detection (over current, low-voltage and short-circuit protection)

54 Inverter compressor

Abnormal inverter fin temperature Abnormal inverter fin thermistor, heat exchanger clogging, fan motor fault

55 Inverter compressor

Inverter fault Inverter PCB fault

56 Fan controller

57 Fan controller Fan controller protection activation Controller IC error signal detection (over current, low-voltage and short-circuit protection), instant over current. Abnormal rotation speed

58 Fan controller Fan controller protection activation Controller IC error signal detection (over current, low-voltage and short-circuit protection), instant over current

59 Inverter compressor

Abnormality inverter fin thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

5A Fan controller Abnormal fan controller fin temperature Fin thermistor fault, heat exchanger clogging, fan motor fault

Fan controller Over current protection activation Fan motor fault

5C Fan controller Abnormal fan controller sensor Current sensor fault (instant over current, increased fin temperature, low voltage, earthing fault, step-out)

96 KPI Unit Sensor

Room Temperature thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

97 KPI Unit Sensor

Fresh air thermistor Incorrect wiring, disconnected wiring, broken cable, short circuit

EE SystemCompressor protection alarm (cannot be reset from the remote controller)

This alarm code is displayed when the following alarms are triggered three times within six hours: 02, 07, 08, 39, 43 to 45, 47

Outdoor unit number setting

Unit number or address number of the outdoor unit incorrectly set

A number greater than 64 has been set for the refrigerant cycle or address

Indoor unit number setting

Connection number of the indoor unit incorrectly set

There are more than 17 units not corresponding to H-LINK II connected to one system

C1 CH unit Incorrect indoor unit connection There are 2 or more CH units connected between the outdoor and indoor units

C2 CH unit Connection number of the indoor unit incorrectly set

There are 9 or more indoor units connected to the CH unit

C3 CH unit Incorrect indoor unit connection Indoor units from different refrigerant cycles have been connected to the CH unit

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 101: 2012 A5 Product Catalogue FULL (3)

Alarm Codes

Alarm Codes for

Checking the 7-Segment display.

SEG.1 SEG.2

8 88 8 8

Upper side

SEG.3 SEG.4 SEG.5

Lower side

Code number Type of Abnormality

8 8 Proceeding Initialisation

8 8p up u8 fh e Heating operation (Normal operation)

h e p o Heating operation (Activation of forced compressor frequency control due to low pressure difference: forced up)

h e p 1 Heating operation (Activation of forced compressor frequency control due to high pressure difference: forced down)

h e p 2h e p 3h e p 4p - 0 6p - 1 1p - 1 2p - 1 7p - 1 8

e 0 (Flickering)

f 8 Fan manual operation

0 2 H 1 Activation of high pressure switch

0 2 h 10 2 L 1 Activation of low pressure control

0 2 e 10 2 6 10 2 9 10 2 E 1

0 40 50 61 1 Failure of water inlet temperature thermistor

1 2 Failure of water outlet temperature thermistor

1 3 Activation of freeze protection control (water inlet)

0 2 1 3 Activation of freeze protection control (water outlet)

1 42 1

For full technical details, refer to Technical Manual

Page 102: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 103

Alarm Codes

Code number Type of Abnormality

2 22 32 42 62 72 83 03 24 05 15 2 Activation of protection for inverter instantaneous over current

5 3 Transistor module protection activation

5 45 75 p6 e6 C

p u (Flickering)

f a Failure of fan motor (MF1)

f 6 Failure of fan motor (MF2)

Alarm Codes for

Continued...

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 103: 2012 A5 Product Catalogue FULL (3)

Alarm Codes

Alarm Code Indication on Remote Control Switch: Alarm indication Alarm code

HITACHI

Code No.

Origin Type of Abnormality Main cause

02 OutdoorActivation of Outdoor Unit Protection Device (Except for Alarm Codes 41, 42)

High-pressure interrupting device activated

03 Outdoor Transmission ErrorOutdoor fuse meltdown, Indoor/outdoor connection wiring (breaking, wiring error, etc.)

04 Outdoor Inverter Transmission AbnormalityControl PCB – Inverter PCB connection wiring (breaking, wiring error, etc.)

05 Outdoor Power Phase Detection Abnormality Power source wiring open phase in Indoor units

06 Outdoor Undervoltage, OvervoltageOutdoor PCB abnormality, inverter PCB abnormality, DM, CB abnormality

07 Outdoor Abnormal Decrease of Discharge Gas Superheat DegreeExcessive refrigerant, expansion valve open-locked, Fan motor locked

08 Outdoor Compressor-Top Temperature Over-IncreaseShortage or leakage of refrigerant, piping clogging, Fan motor locked

11 Indoor Water Inlet Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

12 Indoor Water Outlet Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

13 Indoor Indoor Liquid Pipe Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

14 Indoor Indoor Gas Pipe Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

15 Indoor Water Outlet C2 thermistor Abnormality Loose, disconnected, broken or short-circuited connector

16 Indoor Water DHW Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

17 Indoor Auxiliary Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

18 Indoor Water Outlet Boiler Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

19 Indoor Water Outlet HP Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

20 Outdoor Compressor-Top Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

22 Outdoor Outdoor Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

24 Outdoor Outdoor Heat Exchanger Liquid Pipe Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

31 Outdoor Indoor/Outdoor Combination Setting ErrorOutdoor/Indoor Unit capacity setting error, Indoor total capacity excessively large/small

35 Outdoor Indoor Unit Number Setting ErrorIndoor units with the same number in a refrigerant piping system

Alarm Codes for

For full technical details, refer to Technical Manual

Page 104: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 105

Alarm Codes

Code No.

Origin Type of Abnormality Main cause

38 Outdoor Outdoor Protection Detection Circuit Abnormality Outdoor PCB abnormality, Error in wiring to outdoor PCB

41 Outdoor Cooling OverloadOutdoor heat exchanger clogging/short circuit, Broken outdoor fan motor

42 Outdoor Heating OverloadOutdoor heat exchanger clogging/short circuit, Expansion valve closed-locked

47 Outdoor Suction Pressure Decrease Prevention ActivatedShortage or leakage of refrigerant, pipe clogging, Expansion valve closed-locked, Fan motor locked

48 Outdoor Overload Operation Protection ActivationCycle abnormality, Inverter PCB abnormality, DM abnormality, Heat exchanger clogging, etc.

51 Outdoor Inverter Current Sensor AbnormalityError in CT wiring, Outdoor PCB abnormality, Inverter PCB abnormality

53 Outdoor Inverter Module Error Compressor, ISPM abnormality, Heat exchanger clogging, etc.

54 Outdoor Inverter Fin Temperature AbnormalityFin thermistor abnormality, Heat exchanger clogging, Fan motor abnormality

55 Outdoor Inverter Non-Operation Inverter not operating or broken

56 Outdoor Fan

Fan motor abnormalityDisconnected wire of Incorrect wiring between control PCB and inverter PCB. Incorrect wiring or fan motor abnormality

59 Outdoor Inverter Fin Temperature Thermistor Abnormality Loose, disconnected, broken or short-circuited connector

1 Outdoor Error in Address/Refrigerant System Setting Address/refrigerant system setting over 64

EE Outdoor Compressor Factor AlarmAlarm to notify damage to compressor occurs 3 times within 6 hours

70 Indoor Hydraulic alarm

in the hydraulic cycle

71 Indoor Water Pump Feedback

72 Indoor Thermostat Heater Alarm High temperature is detected in Electric Heater T>75ºC

73 Indoor Mixing overheating limit protection for Mixed circuit Circuit 2 supply temperature > Target temperature + offset

74 Indoor Unit overheating limit protection Two > Tmax +5K

75 IndoorFreeze Protection by Cold water inlet, outlet temperature detection

76 IndoorFreeze Protection Stop by Indoor Liquid Temperature Thermistor

Tl or Tg < -20ºC for 30 seconds (Only heating mode)

77 Indoor Opentherm Communication FailureNo Opentherm communication for a continuous period of 1 minute.

78 Indoor RF Communication FailureNo communication for 1 hour with one or two RF receivers which are bound to the RF-Bridge.

79 Indoor-Outdoor

Unit Capacity Setting Error No concordance between indoor and outdoor unit capacities

80 Indoor LCD

LCD H-link Transmission ErrorNo H-link communication for a continuous period of 1 minute between Indoor and LCD User control by connection wiring (breaking, wiring error, etc.)

Alarm Codes for

Continued...

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 105: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

Alarm Codes

Alarm codes for Samurai Chiller

Function of 7-Segment Light Emitted Diode on

SEG.1 SEG.2

8 8 8 8 7 Segments on Control Panel

CodeContentNo. 1

CycleNo. 2 Cycle

No. 3 Cycle

No. 4 Cycle

No. 5 Cycle

C 1 H 1 C 2 H 3 C 3 H 3 C 4 H 4 C 5 H 5 Activation of High Pressure Switch

C 1 L 1 C 2 L 2 C 3 L 3 C 4 L 4 C 5 L 5 Activation of Low Pressure Protection Control

C 1 L 1 C 2 L 2 C 3 L 3 C 4 L 4 C 5 L 5C 1 5 1 C 2 5 2 C 3 5 3 C 5 5 4 C 5 5 5C 1 6 1 C 2 6 2 C 3 6 3 C 4 6 4 C 5 6 5 Activation of Discharge Gas Thermistor

C 1 7 1 C 2 7 2 C 3 7 3 C 4 7 4 C 5 7 5 Activation of Compressor Internal Thermostat

C 1 9 1 C 2 9 2 C 3 9 3 C 4 9 4 C 5 9 5C 1 8 1 C 2 8 2 C 3 8 3 C 4 8 4 C 5 8 5 Activation of Suction Gas Thermistor

C 1 0 5 C 2 0 5 C 3 0 5 C 4 0 5 C 5 0 5C 1 1 2 C 2 1 2 C 3 1 2 C 4 1 2 C 5 1 2C 1 1 3 C 2 1 3 C 4 1 3 C 4 1 3 C 5 1 3 Activation of Freeze Protection Control (More Than 2 Cycle Unit)

C 1 2 1 C 2 2 1 C 3 2 1 C 4 2 1 C 5 2 1C 1 2 3 C 2 2 3 C 3 2 3 C 4 2 3 C 4 2 3C 1 2 4 C 2 2 4 C 3 2 4 C 4 2 4 C 5 2 4C 1 2 5 C 2 2 5 C 3 2 5 C 4 2 5 C 5 2 5C 1 2 6 C 2 2 6 C 3 2 6 C 4 2 6 C 5 2 6C 1 2 7 C 2 2 7 C 3 2 7 C 4 2 7 C 5 2 7C 1 2 8 C 2 2 8 C 3 2 8 C 4 2 8 C 5 2 8C 1 F 0 C 2 F 0 C 3 F 0 C 4 F 0 C 5 F 0F 1 1 1 F 2 1 1 F 3 1 1 F 4 1 1 F 5 1 1F 1 2 1 F 2 2 1 F 3 2 2 F 4 2 2 F 5 2 2F 1 3 1 F 2 3 1 F 3 3 1 F 4 3 1 F 5 3 1F 1 4 1 F 2 4 1 F 3 4 1 F 4 4 1 F 5 4 1F1 51 F2 51 F3 51 F4 51 F5 51

Page 106: 2012 A5 Product Catalogue FULL (3)

CodeContentNo. 1

CycleNo. 2 Cycle

No. 3 Cycle

No. 4 Cycle

No. 5 Cycle

0 5 0 51 1 1 1 Failure of Water Inlet Temperature Thermistor

1 2 1 21 3 1 3

2 2 2 2S P S P4 0 4 0E U E UF 6 F 6C P C P C1 C2)

“PU”“PU”6 E 6 EA P A P Activation of Additional Protection Device

0 3 0 3F 1 P 7 F 2 P 7 F 3 P 7 F 4 P 7 F 5 P 7F 1 P 8 F 2 P 8 F 3 P 8 F 4 P 8 F 5 P 8C 1 P 5 C 2 P 5 C 3 P 5 C 4 P 5 C 5 P 5C 1 2 8 C 2 2 8 C 3 2 8 C 4 2 8 C 5 2 8C 1 P 6 C 2 P 6 C 3 P 6 C 4 P 6 C 5 P 6

2 1

Self Inspection Functions for Samurai Chiller

Continued...

Normal Indication

CodeContentNo. 1

CycleNo. 2 Cycle

No. 3 Cycle

No. 4 Cycle

No. 5 Cycle

C 1 8 8 C 2 8 8 C 3 8 8 C 4 8 8 C 5 8 8C 1 C 8 C 2 C 8 C 3 C 8 C 4 C 8 C 5 C 8C 1 8 F C 2 8 F C 3 8 F C 4 8 F C 5 8 F

P U P UC 1 C 8 C 2 C 8 C 3 C 8 C 4 C 8 C 5 C 8 Activation of Current Limiter

C 1 E 0 C 2 E 0 C 3 E 0 C 4 E 0 C 5 E 0

For full technical details, refer to Technical Manual

Alarm Codes

Hitachi Product Catalogue | 107

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 107: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

RAC S-Series

Hitachi Product Catalogue | 109

1~/N220-240V / 50Hz

ELB

A B C A B C L1 N

IndoorOutdoor

Key

Mains

Field suppliedisolator

Field suppliedfuse

ELBEarth leakagecircuit breaker

Earth

3 core 1.5mm²shielded

4 core 1.5mm²shielded

Optional wiring

1~/N220-240V / 50Hz

ELB

C

Optionalwired

controller

CN18

DL1 N C D

IndoorOutdoor

RAC Summit < 5.0kW

Optionalwired

controller

CN

18

Optionalwired

controller

CN

18

C1

D1

C1

D1

C2

D2

C3

D3

C2

D2

C3

D3

Optionalwired

controller

CN

18

1~/N220-240V / 50Hz

ELBL1

N

Indoor

Indoor

Indoor

Outdoor

RAC Multizone

1~/N220-240V / 50Hz

ELB

Optionalwired

controller

CN18

L1 N A B C D A B C D

IndoorOutdoor

RAC WX8, Summit > 5.0kW, DH7

Wiring Diagrams

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 108: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

Wiring Diagrams

Key

Field suppliedisolator

Field suppliedfuse

ELBEarth leakagecircuit breaker

Earth

m²2 core 0.75mshielded

Mains

Set Free Mini VRF

Utopia ES, IVX & Centrifugal

Page 109: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

Hitachi Product Catalogue | 111

NL3L2

A B C

L11 2 3 4

ELB

ELB

ELB

L1 N

BA21

3~/N380-415V/50Hz

ELB

1~/N220-240V/50Hz

NL3L2L11 2 3 4

NL3L2L11 2 3 4

L1 N

BA21

ELB

ELB

ELB

L1 N

BA21

L1 N

To next unit

BA21

Indoor

Outdoor

Key

Field suppliedisolator

Field suppliedfuse

ELBEarth leakagecircuit breaker

Earth

m²2 core 0.75mshielded

Mains

Wiring Diagrams

Set Free 2-pipe heat pump

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 110: 2012 A5 Product Catalogue FULL (3)

For full technical details, refer to Technical Manual

Wiring Diagrams

Key

Field suppliedisolator

Field suppliedfuse

ELBEarth leakagecircuit breaker

Earth

m²2 core 0.75mshielded

Mains

Set Free 3-pipe heat recovery

Page 111: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 113

DIP Switches

No. of refrigerant cycle (setting for the first digit)

Address of the indoor unit (setting for the first digit)

Address of the indoor unit (setting for the first digit)

No. of refrigerant cycle (setting for the first digit)

DSW5 / DSW10

DSW4 / DSW1

Setting of DIP switches and RSW switches

Notes: 1.Turn off the power supply before setting the DIP switches. Otherwise, the switch settings are invalid.2.To set the position of the RSW rotary switches, insert a screwdriver into the groove of the RSW.

For full technical details, refer to Technical Manualhitachiaircon.com Email: [email protected]: 01628 585 394

Page 112: 2012 A5 Product Catalogue FULL (3)

Conditions of Sale

(7) In the case of the Buyer residing in the United Kingdom, unless otherwise stated, HITACHI will at its own expense deliver to the Buyer’s premises. In the case of exports, unless otherwise stated, delivery will be FOB (Incoterms 2000) at a U.K. port designated by HITACHI.

(8) The delivery by HITACHI of a greater or lesser quantity of the Goods than the quantity provided for in the Contract, the delivery of other goods not provided for in the Contract, or the delivery of the Goods only some of which are defective, shall not entitle the Buyer to reject all of the Goods delivered. In order that HITACHI can comply with its carrier’s conditions any claim in respect of error in quantity or type of Goods or in respect of damage to the Goods in transit must be made in writing to HITACHI and the carrier notified in both cases within 3 days of receipt of the Goods. Failure to make such claim shall constitute unqualified acceptance of the Goods and waiver by the Buyer of all claims relating to error in quantity or type of goods delivered or relating to the condition of Goods delivered. Similarly, if any Goods invoiced by HITACHI are not delivered, in order that HITACHI can claim against its carriers where appropriate the Buyer must notify HITACHI within 10 days of the date of invoice, failing which the Buyer will be liable to pay for the Goods in full. Where liability for error in quantity, or type of Goods or in respect of damage to the Goods in transit is accepted by HITACHI, HITACHI’s only obligation shall be, at its option, to make good any shortage or non-delivery and/or as appropriate to replace or repair any Goods found to be damaged or defective and/or to refund the cost of such Goods to the Buyer.

(9) If the Buyer refuses or fails to take delivery of Goods tendered in accordance with this Contract HITACHI shall be entitled to terminate this Contract with immediate effect, to dispose of the Goods as HITACHI may determine, and to recover from the Buyer any loss and expenses incurred as a result of such refusal or failure.

(10) Section 32 (2) of the Sale of Goods Act 1979 shall not apply. HITACHI shall not be required to give the Buyer the notice specified in Section 32 (3) of the Act.

(11) Unless expressly agreed in writing by HITACHI, all Goods shall be packed in accordance with HITACHI’s standard practice. The Buyer shall meet the costs of any special packaging requested by the Buyer or any packaging rendered necessary by delivery by any means other than HITACHI’s normal means of delivery.

(1) Notwithstanding delivery, property in the Goods supplied shall remain with HITACHI until those Goods and any other goods the subject of any other contract with HITACHI have been paid for in full (together with any accrued interest) and until property passes in accordance with this term:-

(a) Risk in the Goods shall pass on delivery and the Buyer shall store the Goods separately or in such a way as will show clearly that they are HITACHI’s property and the Buyer will ensure that they are kept in good condition and insured against loss or damage for HITACHI’s benefit. Until property in the Goods passes to the Buyer, the Buyer shall hold the proceeds of any claim on the insurance policy on trust for HITACHI and shall immediately account to HITACHI with the proceeds.

(b) The Buyer shall hold the Goods in a fiduciary capacity and as bailee for HITACHI who may without prejudice to any other of its rights repossess the Goods to which it has retained title as aforesaid and thereafter re-sell the same and for this purpose the Buyer hereby grants an irrevocable right and licence to HITACHI’s servants and agents to enter upon all or any of its premises with or without vehicles during normal business hours for the purpose of inspecting and/or repossessing Goods to which it has retained title. This right shall continue to subsist notwithstanding the termination of this Contract for any reason and is without prejudice to any accrued rights of HITACHI hereunder or otherwise.

(c) The Buyer may dispose of the Goods in the ordinary course of its business as principal and may pass title to a third party but the proceeds of sale arising therefrom shall be kept in a separate account on trust for HITACHI until such time as full payment for the Goods supplied has been made.

(d) HITACHI may at any time detach or separate any of its Goods which may have been incorporated in or attached to goods belonging to the Buyer or any third party.

(2) HITACHI reserve the right, exercisable at its option by notice in writing to the Buyer, to waive the provisions of subclause 5(1) above at any time before payment has been made for the Goods supplied by the Buyer and to declare that property in the Goods shall have passed to the Buyer.

(3) Notwithstanding that property in the Goods shall not have passed to the Buyer, HITACHI, without prejudice to any other of its rights, may sue for the price of the Goods supplied in the event that payment is not made on the due date.

(4) Any return of Goods wholly or partly by the Buyer to HITACHI, except in the case of defective Goods pursuant to Clause 8, shall be subject to HITACHI’s prior written consent and Buyer’s payment to HITACHI of interest charges for the period from the date of HITACHI’s shipment of

1. DEFINITIONS In these conditions;(1) “HITACHI” means: Hitachi Air Conditioning Europe SAS, UK Branch

(registration no. BR015653), Whitebrook Park, Lower Cookham Road, Maidenhead, Berkshire, SL6 8YA, United Kingdom.

(2) “Buyer” means: the person, firm or company specified overleaf, to whom HITACHI’s Quotation, Sales Confirmation or Invoice is addressed.

(3) “Goods” means: the goods to be sold by HITACHI to the Buyer under the Contract.

(4) “Contract” means: the contract of sale hereby formed between HITACHI and Buyer.

2. CONSTRUCTION OF CONTRACT(1) The terms of the Contract shall consist of the particulars overleaf and

these conditions. Any term overleaf which is at variance with these conditions shall prevail over these conditions, which shall be construed accordingly, except with regard to price in respect of which provisions of subclause 6 (2) shall prevail.

(2) No other terms (whether contained in any document issued by the Buyer or in any written or oral communication between the parties) shall apply to the Contract nor shall these conditions or the particulars overleaf be modified without HITACHI’s written agreement.

(3) These conditions and the particulars overleaf shall be a complete record of the agreement between the parties with regard to the sale of the Goods. These conditions apply to all sales of Goods by HITACHI to the Buyer and shall apply in place of and prevail over any terms or conditions contained or referred to in the Buyer’s order or in correspondence or elsewhere or implied by trade, custom, practice or course of dealing unless agreed to in writing pursuant to subclause 2 (2) above and any purported provisions to the contrary are hereby excluded or extinguished.

(4) The Buyer must ensure that any pre-contractual representation on which it wishes to rely has been specified in the particulars overleaf. In entering the Contract, the Buyer does not rely upon any such representation made by or on behalf of HITACHI which has not been so specified.

(5) The acceptance by HITACHI of any Buyer’s order, wholly or partly, does not imply any commitment by HITACHI to accept any other order (or any other part of an order) whenever placed.

3. QUOTATIONS AND ORDERS(1) Unless accepted before lapse or withdrawal, or renewed in writing by

HITACHI, quotations shall lapse automatically after 30 days, but may be withdrawn earlier by HITACHI.

(2) Quotations are for information only and are not firm offers. There shall be no binding contract until HITACHI has accepted the buyer’s order by despatching HITACHI’s official Sales Confirmation.

(1) The scope of supply by HITACHI under the Contract shall be strictly limited to those specified overleaf, and no other goods or services are included.

(2) HITACHI will use all reasonable endeavours to deliver the Goods on or before the delivery date specified overleaf, however, HITACHI does not undertake, guarantee or warrant that delivery will be made on the delivery date specified.

(3) Any such delivery date specified shall be extended by any period or periods during which the manufacture or delivery of the Goods or other work by HITACHI in connection with this Contract is prevented, hindered, delayed or rendered uneconomic by reason of a Force Majeure Event (as defined in clause 19 below).

(4) The Buyer acknowledges that, in the case of semiconductor products, optoelectronic products and other electronic components, due to the advanced technology in the Goods and the specialist nature of the manufacturing process, manufacture of the Goods by HITACHI’s normal means may result in a loss of yield. In the event of such a loss of yield HITACHI shall notify the Buyer and shall use its best endeavours to supply the Goods in accordance with this Contract. If due to a Force Majeure Event or due to loss of yield HITACHI has insufficient stocks to meet all its commitments HITACHI may apportion stock between its customers at its sole discretion.

(5) If any delivery time specified overleaf is so extended by more that 90 days then the Buyer shall be entitled to give written notice to HITACHI requiring the Goods to be delivered within 30 days of the date of such notice, failing which the Buyer shall have the right to give further written notice determining the Contract forthwith.

(6) HITACHI shall be entitled to deliver the Goods in one or more instalments. Where delivery is effected by instalment each instalment shall be treated as a separate contract. Delay in delivery or other default of any instalment shall not relieve the Buyer of its obligations to accept and pay for the remaining deliveries.

Page 113: 2012 A5 Product Catalogue FULL (3)

Hitachi Product Catalogue | 115

Conditions of Sale

from defective materials, faulty workmanship or otherwise howsoever arising and whether or not caused by the negligence of HITACHI, its employees or agents SAVE THAT HITACHI shall accept liability for death or personal injury caused by the negligence of HITACHI.

If the Buyer fails to pay HITACHI in accordance with these conditions or breaches any other of these conditions or any other contract with HITACHI or enters into a deed of arrangement or commits an act of bankruptcy or compounds with his creditors or if a receiving order is made against him or if (being a company) an order is made or a resolution is passed for the winding-up of the Buyer (otherwise than for the purposes of amalgamation or reconstruction previously approved in writing by HITACHI) or if a receiver is appointed over any of the Buyer’s assets or undertakings or if circumstances arise which entitle the Court or a creditor to appoint a receiver or manager or which entitle the Court to make a winding-up order or if the Buyer takes or suffers any similar or analogous action in consequence of debt HITACHI may, without prejudice to its other rights, postpone delivery or manufacture (both in respect of the Contract in question and any other contracts HITACHI might have with the Buyer) until such payment has been made or other breach rectified and/or (at its option) to terminate the Contract (and/or any other such contracts) and to recover payment for all deliveries already made and for the cost of materials and labour already expended for the purpose of future deliveries (less any allowance of the value thereof as utilised by HITACHI for other purposes) and also to recover from the Buyer a sum equivalent to HITACHI’s loss of profit arising out of such termination. The exercise of HITACHI’s option to postpone delivery or manufacture shall not prevent the subsequent exercise of HITACHI’s option to terminate the Contract and/or any other such contracts.

10. THIRD PARTY RIGHTS(1) In this clause 10 “Third Party Rights” shall mean any rights under letters

patent, registered or unregistered designs, trademarks, copyright or any other intellectual property rights and rights in know-how whether or not capable of being protected by statute, which are owned or controlled by any third party.

(2) Where any of the Goods are produced to the Buyer’s specification or where the Buyer’s use of the Goods infringes any Third Party Rights notwithstanding that the Goods themselves do not constitute such an infringement, the Buyer shall indemnify HITACHI against all actions, claims, costs, damages or losses arising from any infringement of such rights in respect of the Goods so produced or the use to which the Buyer has put the Goods as the case may be.

(3) Any reference by HITACHI to patents, copyright, registered designs, trade marks and analogous forms of protection shall not constitute a warranty of the validity thereof.

(4) HITACHI does not warrant that the Goods do not infringe any Third Party Rights, and all warranties to that effect whether express or implied, statutory or otherwise are hereby excluded. If at any time it is alleged that the Goods infringe any Third Party Rights, or if in HITACHI’s reasonable opinion such an allegation is likely to be made, HITACHI may at its option and at its own expense:

(a) modify or replace the Goods without detracting from the overall performance of the Goods, so as to avoid the infringement; or

(b) procure for the Buyer the right to continue to use the Goods; or (c) repurchase the Goods at the price paid by the Buyer.(5) HITACHI shall have no liability to the Buyer in the event of Goods infringing

or being alleged to infringe any Third Party Rights. In the event that the Goods are or may be the subject of Third Party Rights, HITACHI shall be obliged to transfer to the Buyer only such right, title or interest as HITACHI may have.

(6) The Buyer shall notify HITACHI forthwith of any claim made or action brought or threatened alleging infringement of any Third Party Rights. HITACHI shall have control over and conduct any such proceedings in such manner as it shall determine. The Buyer shall provide all such reasonable assistance in connection therewith as HITACHI may request.

(1) Unless expressly agreed in writing by HITACHI, all drawings, designs, specifications and particulars of dimensions and weights and other such information submitted by HITACHI are approximate only and HITACHI shall have no liability in respect of any deviation therefrom. HITACHI shall be entitled to amend the technical specifications of the Goods without notice.

(2) HITACHI accepts no responsibility for any errors, omissions or other defects in any drawings, designs or specifications prepared by, or on behalf of, the Buyer or the Buyer’s agents, sub-contractors or employees, and HITACHI shall be indemnified by the Buyer against any and all liabilities and expenses incurred by HITACHI arising therefrom.

such Goods to the Buyer to the date of HITACHI’s receipt of such Goods. Freight, insurance and any other expenses incurred in connection with such return shall be borne by the Buyer.

6. PRICES(1) Unless otherwise stated overleaf, prices of the Goods shall be exclusive of

VAT, export duty and foreign import duty and any other import or other taxes, which shall where applicable be the subject of additional charges.

(2) Prices stated in any quotation or in HITACHI’s Sales Confirmation are provisional only and subject to adjustment to take account of increases in HITACHI’s costs and overheads, including, without limitation, costs of carriage and labour costs. The Contract price shall be HITACHI’s price ruling at the date of despatch. All quotations/sales confirmations and invoices are issued subject to the unconditional reservation of HITACHI’s right to adjust prices in respect of the following:-

(a) Changes in the prevailing exchange rate between the currency in which the price is to be paid and the Japanese Yen.

(b) Changes in the current EU import duty.

(1) (1) If HITACHI has granted the Buyer credit facilities, the payment of the price must be made in full within 30 days of the date of invoice, unless otherwise specified overleaf or agreed to by HITACHI. Any extension of credit allowed for the Buyer may be changed or withdrawn at any time. Where no credit has been granted, payment must be made in full in cash prior to delivery. Payment shall be made in full direct to HITACHI in the currency invoiced. The Buyer shall not be entitled to exercise any right of set-off, counterclaim, abatement or analogous deduction against payment due to HITACHI. Time of payment is of the essence of a Contract. HITACHI reserves the right to suspend the provision of Goods to the Buyer where any amounts are overdue under any Contract with the Buyer until all such amounts have been paid.

(2) HITACHI shall be entitled to charge daily interest on any overdue sum at the rate of 3 per cent per annum above the current base lending rate of Barclays Bank PLC from due date until the date of actual payment in full (including any accrued interest) (after, as well as before, judgement).

(3) If, in the opinion of HITACHI, the creditworthiness of the Buyer shall have deteriorated prior to the delivery, HITACHI may require full or partial payment of the price prior to delivery or the provision of security for payment in full (including any accrued interest) by the Buyer in a form acceptable to HITACHI notwithstanding any credit terms that may have been agreed between HITACHI and the Buyer.

(4) Notwithstanding any purported contrary appropriation by the Buyer, all payments made by the Buyer to HITACHI shall be appropriated first to Goods which have been resold by the Buyer and then to Goods which remain in the possession or under the control of the Buyer.

(5) HITACHI is entitled to offset any amount owing to it from the Buyer against any amount owed to the Buyer by HITACHI.

8. DEFECTIVE GOODS(1) If the Goods are defective on delivery, and the defects arise from faulty

materials or workmanship and are not caused by fair wear and tear, abnormal or unsuitable conditions of storage, transportation or use, or the combination of the Goods with any goods not supplied by HITACHI or any act, neglect or default of the Buyer or any third party and HITACHI is given written notice of the defects promptly upon discovery by the Buyer and at any rate within six months (or such other period of time as may specifically be agreed to by HITACHI for certain types of Goods) after delivery then, unless otherwise specified overleaf, HITACHI’s sole obligation shall be (at its option) to repair or replace the defective item or allow the Buyer the price thereof and to pay or reimburse the reasonable carriage charges for the return of defective Goods to HITACHI and for delivery of the replaced or repaired item.

(2) Unless otherwise agreed between HITACHI and the Buyer, if any of the Goods are not HITACHI made, the provisions of subclause 8(1) above shall apply only to the extent covered by any warranty made by the supplier of such Goods to HITACHI.

(3) The Buyer shall retain the Goods at its premises until instructed by HITACHI to return them. Goods alleged to be defective shall be subject to inspection and testing by HITACHI at its own or (if HITACHI so chooses) at the Buyer’s premises and the Buyer shall allow HITACHI adequate facilities at the Buyer’s premises to investigate the complaint.

(4) Subject to subclause 8(1) above, HITACHI gives no representation or warranty and there is not incorporated in the Contract any condition whether express or implied, statutory or otherwise, as to the Goods other than the statutory warranty of title, and any such representations, conditions or warranties are hereby expressly excluded and HITACHI shall be under no liability to the Buyer for any loss, damage or injury (including special, direct, indirect or consequential loss and loss of profit) resulting

hitachiaircon.com Email: [email protected]: 01628 585 394

Page 114: 2012 A5 Product Catalogue FULL (3)

Conditions of Sale

16. WAIVER Failure by HITACHI to exercise or enforce any rights hereunder shall not

be deemed to be a waiver of any such right nor operate so as to bar the exercise or enforcement thereof at any time or times thereafter.

17. NOTICES Any notice hereunder shall be deemed to have been duly given if sent by

pre-paid first class post, telex, or telefax to the party concerned as its last known address. Notices sent by first class post shall be deemed to have been given seven days after despatch and notices sent by telex or telefax shall be deemed to have been given on the date of despatch.

The contract may be cancelled or rescheduled by the Buyer only with HITACHI’s written consent. In the event of such cancellation the Buyer shall pay to HITACHI a cancellation charge, equal to HITACHI’s cost incurred up to the date of cancellation plus HITACHI’s loss of profit. The amount of such charge shall be notified to the Buyer upon HITACHI’s written acknowledgement of cancellation and shall be paid within 30 days of such notification.

(1) If HITACHI is prevented, hindered or delayed from or in supplying the Goods in accordance with these conditions by a Force Majeure Event HITACHI may, at its option:

(a) suspend deliveries while the Force Majeure Event continues;(b) if HITACHI has insufficient stocks to meet its commitments, apportion

available stocks between its customers as it decides; or(c) terminate any contract so affected with immediate effect by written notice

to the Buyer; and HITACHI shall not be liable for any loss or damage suffered by the Buyer as a result.

(2) In this clause “Force Majeure Event” means an event beyond the reasonable control of HITACHI including, without limitation, strike, lock-out, labour dispute or shortage of labour, act of God, war, riot, civil commotion, malicious damage, compliance with a law or governmental order, rule, regulation or direction, accident, breakdown of plant or machinery, fire, flood, storm, earthquake, shortage of utilities, materials or other circumstances affecting the supply of materials from HITACHI’s normal source of supply for materials for the Goods.

The Buyer shall be responsible for all obligations, financial or otherwise, imposed in respect of the Goods, on either of the parties, under any environmental legislation applicable to the parties, including but not limited to Directive 2002/96/EC on waste electrical and electronic equipment and any legislation enacted pursuant to it.

The law of the Contract shall be English law and the parties hereby submit to the jurisdiction of the English Courts save that HITACHI shall be entitled to bring proceedings against the Buyer in the courts of any jurisdiction where the Buyer resides or carries on business.

The Buyer agrees that it shall not obtain any right, title or interest in or to any intellectual property (including, without limitation, patents, trademarks, registered or unregistered designs, copyrights and rights in designs or inventions) in the Goods and that it shall not do or permit anything to be done in its use of such intellectual property in the Goods which would or could jeopardise their validity.

(1) Headings herein are for easy reference purpose only, and shall not be construed as defining the scope or meaning of any provisions.

(2) The invalidity, illegality or unenforceability of the whole or part of a condition does not affect or impair the continuation in force of the remainder of these conditions.

(3) A person who is not a party to this contract has no right under the Contracts (Rights of Third Parties) Act 1999 to enforce any of its terms but this does not affect any right or remedy of a third party which exists or is available apart from that Act.

(4) A reference to a statutory provision includes a reference to the statutory provision as modified or re-enacted or both from time to time and any subordinate legislation made under the statutory provision.

April 2012

(3) All drawings, designs, specifications and information submitted by HITACHI are confidential and shall not be disclosed to any third party without HITACHI’s written consent.

(1) HITACHI shall not be liable for any indirect or consequential loss, loss of revenue, loss of goodwill, and/or loss of anticipated savings in each case howsoever caused.

(2) Without prejudice to subclause 12(1) HITACHI shall not be liable to the Buyer for any loss or damage whether for negligence, breach of contract, misrepresentation or otherwise, for a sum greater, in aggregate, than the amount actually paid by the Buyer to HITACHI under the Contract.

(3) The limitation of liability in subclauses 12(1) and 12(2) above shall not operate to exclude or restrict HITACHI’s liability for fraud or deceit or for death or personal injury caused by its negligence.

(4) For the avoidance of doubt HITACHI will have no liability to the Buyer for any delays in deliveries due to circumstances described in subclauses 4(3) and 4(4) of these conditions.

Neither party shall without the prior written consent of the other party (which shall not be unreasonably withheld) assign or sub-contract any of its rights or duties under the Contract and upon such consent being given shall furnish copies of any such assignments to the other party.

(1) If any license or consent of any government or other authority shall be required for the acquisition, carriage or use of the Goods by the Buyer, the Buyer shall obtain the same at its own expense and if necessary produce evidence of the same to HITACHI on demand. Failure to do so shall not entitle the Buyer to withhold or delay payment of the price. Any additional expenses or charges incurred by HITACHI resulting from such failure shall be for the Buyer’s account.

(2) If HITACHI needs to obtain an export license from the competent authorities of the U.K. or, in the case of a drop shipment, of another country, the Buyer shall furnish HITACHI with all information required by HITACHI for such purpose, including, but not limited to, the country of ultimate destination and the name and address of the consignee, and shall warrant that such information is true, accurate and sufficiently detailed. The Buyer further agrees to take all necessary procedures in connection therewith, including, but not limited to, application for and acquisition of international import certificate, import license and delivery verification, as applicable. The Buyer shall not directly or indirectly re-export the Goods, wholly or partly, or any relevant technology, services or technical data to those countries, the export of such Goods, technology, services or data to which is restricted under the laws of the government issuing the said relevant export license (except where such export license specifically approves). In the event that any of the Goods, or any materials, parts or components incorporated in them, or relevant technical data supplied by HITACHI are of United States origin, the Buyer agrees to comply with the U.S. Export Administration regulations.

(3) The Buyer shall not export, re-export or make available the Goods, wholly or partly or any relevant technical data to any destinations subject to United Nations, EC and/or national sanctions, or to any person or organisation subject to United Nations, EC and/or national sanctions, or for any purpose prohibited by such sanctions. The Buyer shall not resell the Goods, whether directly or indirectly, for export to a country in breach of any export controls, laws, rules or regulations of the country of origin of the Goods.

(4) The Buyer confirms that the Goods or any relevant technical data will not be used for purposes related to the proliferation of any weapons of mass destruction (chemical, biological or nuclear weapons and related missiles).

(5) The Buyer shall keep documentation for at least four (4) years from the date of HITACHI’s shipments as evidence that all Goods supplied to the Buyer have been received in the destination permitted under the laws of the government issuing the export licence, and the Buyer will produce such evidence upon HITACHI’s request.

(6) HITACHI’s obligations under any Contract shall be conditional upon all necessary licenses or consents being obtained from the relevant authorities.

(7) The Buyer shall separately confirm to HITACHI the strict observation hereof (Notice of Confirmation).

In any case where Goods are sold CIF or FOB or on the basis of other international trade terms, the meaning of such terms contained in Incoterms 2000 as revised from time to time shall apply except where inconsistent with any of the provisions contained in these conditions.

Page 115: 2012 A5 Product Catalogue FULL (3)

Specifications in this catalogue are subject to change without notice in order that HITACHI may bring the latest innovations to their customers, omitting typing errors.

Hitachi Air Conditioning Europe SAS.Whitebrook Park, Lower Cookham Road, Maidenhead, Berkshire SL6 8YA United Kingdom

tel: 01628 585 394

email: [email protected]

www.hitachiaircon.com

HELGB PC 001_12