2016 LG PTAC
“Innovation for a Better Life”
PTAC – Features
Outside Air Damper and Filter Indoor and Outdoor
Motor
Defrost Controller
Four Sensors Temperature
Control
Emergency Heat
Freeze Room Protection
Power Cord and Plug
High Efficiency Compressor
• Strong Brand Name • EERs up to 13.3 • LG Brand Compressors known for low sound levels • LG Brand BLDC Motors • Dehumidification Features • Plastic Drain Pans • Gold Fin® Anti-Corrosion protection • Ceramic Heaters (230/208 units) • Made by LG Employees in LG Factory • Compatible with most Energy Management Systems • Includes 4.26’ Electrical Cord with Plug • Room Anti-Freeze Protection • Auto Restart • May Improve Guest Satisfaction Scores
LG Value Proposition
PTAC Capacities from 7,000 to 15,000 Btu/h
• Energy Saving - Up to 13.3 EER
• Low Sound Levels - Indoor unit sound pressure 45dB
• Features - Energy Saver Mode - Auto Restart - Digital Control Display - 8 Temperature/function limiting settings through dip switches - GoldFin™ anti-corrosion treatment for condenser coil - Dehumidification Features - Optional Energy Management System
11
Owners Manual Location / Thermostat Connection Wires
Top of the PTAC Container
PTAC Wire Harness Kit – AYWH110
Located in top of corrugated container
Energy Management System – Simple Room Thermostat
Controller
- Wired PYRCUCA0B
- Wireless PYRCUCC1HB
• PYRCUCC1HB Wireless Controller Kit Contains
- Wireless Controller - Connection Cable - Controller Board - Two Batteries - Third Party Connection Cable
Energy Management System – Simple Room Thermostat
• PYRCUCC1HB Wireless Controller Kit Connection
- Open Panel - Connection Cable - Extend Module to under panel - Two Batteries into Controller
Outside Temperature Range
Compressor in cooling mode - Functions between 115⁰F - 54⁰F Compressor in heating mode (heat pump model) - Functions between 75⁰F down to 34⁰F Freeze Protection -When the unit senses the room temperature to be less than 40⁰F (indoor temperature) the electric heater and evaporator fan will begin operation - Unit must have power available to have this function operational - This function overrides all external controls - LED on the control panel displays "FP"
18
Condensate Drain Valve
Top view
Bottom View
Automatically Opens at 45⁰F
Only in Heap Pump Unit
Helps prevent condensate from freezing in base pan (defrost cycle)
Set-Point Limiting
• Eight Set Points
- Three dip switches
- Cooling mode
- Heating mode
Wired Wall Mount Controller
PTAC Dip Switch Setting that Change Units Function
Unit operates without electric heater Force H/P model to operate like cooing only unit
PTAC – Sleeve – Grille Assembly
PTAC – Installation in Wall (Front View)
PTAC – Installation in Wall (Side View)
25
Front and Rear Clearance
Owners Manual P/NO MFL67646801
Wall Sleeve – Four Piece – AYFDSV01A
28
Sleeve – Precaution to Help Prevent Leaks
Owners Manual P/NO MFL67646801
Check the bottom corner’s joint gap of the sleeve, if there is a gap then fill the gap with putty
Wall Sleeve – Insulation Piece to Help Prevent Air Recirculation
Wall Sleeve – Insulation Piece to Help Prevent Air Recirculation
1) Take out the insulation strip from the upper packing. 2) Attach the insulation strip onto the rear upper side of the wall sleeve. 3) Insulation strip prevents the exhaust air from re-entering from either side of condenser space which may decrease the cooling efficiency of condenser. Installation of the insulation strip should also help prevent high pressure default - error code CH 34.
31
Insulation Material Location – Top of Container
Subbase – AYSB*101A
Condensate Removal – Slinger Ring on Condenser Fan
Slinger Ring
Drain Kit – AYDR101A
PTAC – Electrical Plug Assembly
LP073CD2B LP073HD2B LP093CD3B LP093HD3B LP123CD3B LP123HD3B LP153CD3B LP153HD3B
LP096CD3B LP096HD3B LP126CD3B LP126HD3B
PTAC – Electrical Cord and Plug Assembly 265v
LP096CD3B LP096HD3B LP126CD3B LP126HD3B
PTAC – Electrical Plug Assembly – 208v / 230v Plug
208v / 230v Plug
PTAC – Electrical Plug Assembly – 265v / 277v Plug
265v / 277v Plug
Sound Levels - Noise Reduction Features
Sound reducing insulation on the separation panel between inside and outside of unit
Sound dampening material on the compressor for noise suppression
Isolators on the refrigeration pipe lines to suppress vibration and noise from the compressor
Control Panel
Control Panel – Escutcheon Kit – AYRE110
Used to cover control panel when
optional wall
controller is applied
Two Position Discharge Grille Louver Angles
Front Grille Sponge Rubber Anti Vibration Application
Lateral Duct Kit – AYLD1A
Used to Allow Ducted Air to Adjoining Area
Motor
• Motor
- Two Motors
- Evaporator section
- Condenser Section
- Brushless Digital Controlled Motor
- Low noise levels
- High Reliability
Indoor Motor
Outdoor Motor
PAC-PI-FA-001-US 013E10
Gold Fins TM
• Gold Fins
- Standard for all LG PTAC models
- Anti-corrosion treatment on condenser
- Longer coil life
- Prevents rust and corrosion
Gold Fins
PAC-PI-FA-001-US 013E10
Gold Fins
Drain Pan
• Drain Pan
- Durable Plastic
- Improved Quality
- Longer Life
Plastic
PAC-PI-FA-001-US 013E10
Drain Pan - Competitor Styrofoam Drain Pan Contamination
Ventilation
• Ventilation
- Assembly
- Port opens completely
- Filter
- Mesh filter
- Reduces dust levels
Mesh Filter Mesh Filter
• Ventilation
- Sliding Switch
- Easy to use Ventilation Switch
PAC-PI-FA-001-US 013E10
Electric Heater
• PTC Ceramic (230V Models)
• Coil Heater (265V Models)
• Instant Heating
• Safe operation
• Longer life
Coil Heater
PTC Ceramic Heater
PAC-PI-FA-001-US 013E10
PTAC Maintenance Tips
Frequency Maintenance Procedure
Monthly Clean Air Filter
Clean Front Cover
Quarterly Clean Indoor Coil
Clean Blower Wheel
Annually Clean Outdoor Coil
Clean Base Pan
Outdoor Coil
Front Cover
Air Filters
Blower Wheel
Indoor Coil
Base Pan
A consistent PTAC maintenance schedule ensures operation at
optimum efficiency levels and delivers superior
performance
LG Ease of Service • Indoor Coil angles forward with the
removal of just a few screws – Fan Motor Replacement/Service – Fan Wheel cleaning – Ceramic Heater Element Service – Annual Evaporator Cleaning – Faster problem diagnosis
Fan Motor
Fan Wheel
Ceramic Heater
Evap. Coil
PTAC Maintenance Tips – Ease Internal Cleaning
Warranty Process
1 Provide Information to LG
3 Retain Case Number
Model Number Serial Number Location of Unit Description of Problem Contact Name, Phone Number & Email Date of Purchase*
2 Service During the 1st Year Limited Warranty A service center will be assigned to provide the limited warranty service
During the 2-5 Years Parts Warranty LGEAI will send a servicer with the parts needed for repair (no labor reimbursement) Sealed system repairs will be dispatched to a servicer (parts and labor included)
Customer
LG Service
4 Resolution Your LG Helpdesk Representative will follow up on each repair until completion
All case numbers should be retained for future reference
* Proof of purchase may be required for service
One Call Answers All 888-865-3026
8 A.M. – 6 P.M. CST Monday - Friday
Product Rating Plate – Information for Warranty Service
Rating Plate Location For Model Number
Serial Number Tag Location
Product Rating Plate – Information for Warranty Service
Rating Plate Location
Serial Number Tag Location
Error Codes – “B” Models
Thank You!