industrialYYC.com
FOR LEASEFABRICATION/SERVICE SHOP
©2017 Coldwell Banker Real Estate LLC, dba Coldwell Banker Commercial Affiliates. All Rights Reserved. Coldwell Banker Real Estate LLC, dba Coldwell Banker Commercial Affiliates fully supports the principles of the Equal Opportunity Act. Each Office is Independently Owned and Operated. Coldwell Banker Commercial and the Coldwell Banker Commercial Logo are registered service marks owned by Coldwell Banker Real Estate LLC, dba Coldwell Banker Commercial Affiliates. This brochure is intended for information purposes only and should not be relied upon for accurate factual information by the recipients hereof. The information contained herein is based on information which Coldwell Banker Commercial West Real Estate (the “Brokerage”) deems reliable, however, the Brokerage assumes no responsibility for the degree of accuracy of such information, nor does the Brokerage represent or warrant the information contained herein. The information contained herein is subject to change without notice.
Coldwell Banker Commercial West 1208, 734 7 Ave SW
Calgary, AB T2P 3P8
CBCWestRealEstate.ca industrialYYC.com
West Real Estate - Industrial YYC
IND
UST
RIA
L
• Engineered structural steel building designed with capacity to accommodate multiple 10 ton cranes
• Ideal fabrication/service shop• Warehouse Concrete Floor: Designed and
reinforced to support heavy industrial loads and crane capacities
• Great Location on the east side of Calgary with quick and easy access to Glenmore Trail and Stoney Trail.
• 2 Oversized Overhead Loading Doors with sunshine panels, which greatly increase the amount of natural light in the Building during
daytime hours• Yard Area available directly to the west of the
building. • Additional short-term land available for
lease at $0.80 psf
233167 Range Road 283 - Building L11,529 ft²
Kaile [email protected]
Jason [email protected]
Mark [email protected]
Property Highlights
West Real Estate - Industrial YYC
IND
UST
RIA
L
CBCWestRealEstate.ca industrialYYC.com
FOR LEASE233167 RANGE ROAD 283 - BUILDING L
IND
UST
RIA
L
Total Area 11,529 ft2
Warehouse: 7,623 ft2
Office Area: 1,953 ft2
Mezzanine: 1,953 ft2
Zoning: B2Lease Rate: $9.50Operating Cost: $2.31
Crane Charge psfFirst 10 ton crane cost $1.35First 15 ton crane cost $1.70Second 10 ton crane cost $1.10Second 15 ton crane cost $1.45
Glenmore Trail SE
Range Road 283
Kaile [email protected]
Jason [email protected]
Mark [email protected]
11,529 ft2
Yard Area
Access for South Bay Tenant
Property Details
Additional crane charge
Ceiling Height: 36 ft clear
Power: 3 Phase 600VAC 400A
Crane Capability :
Building engineered for multiple 15-ton crane loading, with 29 ft hook height
Loading: 1 Drive In Door - 25’x 25’1 Drive In Door - 18’x25’
Lighting: 4-lamp T5 light fixtures throughout the warehouseFive (5) exterior security lights on adjustable timer, 400W and 5,000K
4 min drive to Stoney Trail SE
N
West Real Estate - Industrial YYC
IND
UST
RIA
L
CBCWestRealEstate.ca industrialYYC.com
FOR LEASE233167 RANGE ROAD 283 - BUILDING L
IND
UST
RIA
L
1
2
3
4
5
6
7
A B C D E F G H J
1
4
7
1a
1b
1d
4a
4d
1c
4b
4c
1
2
3
4
5
6
7
G H J
APRIL 30/15 ISSUED FOR PERMIT & CONSTRUCTION.
Main Floor Plan Mezzanine Plan Door Schedule
Revisions:
JOB No.
DATE:
DRAWN:
Drawing Title:
THIS
PLA
N A
ND
DES
IGN
AR
E, A
ND
AT
ALL
TIM
ES R
EMA
IN T
HE
EXC
LUSI
VE P
RO
PER
TY O
F R
ICK
BA
LBI A
RC
HIT
ECT
LTD
. A
ND
CA
NN
OT
BE
USE
D O
R R
EPR
OD
UC
ED W
ITH
OU
T W
RIT
TEN
CO
NSE
NT.
Sheet A3 of 5
Mechanical:
DO
NO
T SC
ALE
DR
AW
ING
S: A
NY
DIS
CR
EPA
NC
IES
AR
E TO
BE
REP
OR
TED
TO
TH
E A
RC
HIT
ECT
PRIO
R T
O T
HE
CO
MM
ENC
EMEN
T O
F A
NY
WO
RK
Electrical:
Seal:
Site Servicing:
Structural:
Project:
WAREHOUSE BUILDING "B"
RR 283 & Glenmore Trail S.E.
Calgary, Alberta
905748 ALBERTA LTD. Box 72154 RPO Glenmore Landing
Calgary, Alberta Ph: (403) 252-7866 Fax: (403) 255-7364
[email protected] (ALSO OPERATING AS PROFESSIONAL PIPE)
18' X
25'
O.H
. DO
OR
25' X
25'
O.H
. DO
OR
18' X
25'
O.H
. DO
OR
25' X
25'
O.H
. DO
OR
MAIN FLOOR PLAN SCALE: 1 : 100 AREA: ± 1,779.8 sq.m.
Rick Balbi Architect Ltd. #15 -5917 - 1"A" Street S.W. Calgary, Alberta T2H 0G4
Ph: (403) 253 - 2853 Fax: (403) 253 - 3078 [email protected]
DN 20R
DN 20R
TRAVEL D
ISTANCE: ±
14.4m
TRAVEL DISTANCE: 15m
MEZZANINE PLAN SCALE: 1 : 100
MAXIMUM ALLOWABLE TRAVEL DISTANCE TO STAIR = 15M.
UP 20R
UP 20R
MEZZANINE O
VER
MEZZANINE O
VER
ALL INTERIOR PARTITION & WASHROOM LOCATIONS
IS TO BE DETERMINED AT TIME OF TENANCY DEVELOPMENT.
TYPICAL OVERHEAD DOOR: - SIZE AS PER PLAN. - MIN. R-16 INSULATED STEEL SECTIONAL O.H. DOOR ("WHITE"). - CLEAR VISION PANELS AS PER ELEVATIONS. - ELECTRIC OPERATOR C/W SAFETY REVERSE (JACK SHAFT TYPE) & EMERG. CHAIN HOIST; PUSH BUTTON STATION BESIDE DOOR. - ELEC. EYE FOR REMOTE CONTROL OPERATION.
- optional - to be confirmed by owner. - 3" H.D. HIGH-LIFT HARDWARE W/ CONT. ANGLE. - SINGLE PHASE 1/2 HP OR 3/4 HP AS REQ'D. - WEATHERSTRIPPING ALL AROUND & BOTTOM SEAL.
3.0M CONC. APRON W/ SLOPE AWAY FROM BUILDING.
future room below
Overall Mezzanine ± 174 sq.m.
Storage Mezzanine ± 174 sq.m.
14-214July 15, 2014
SF / LM
AUG 18/14 EXT. RATED WALL REV'D, ISSUED FOR REVIEW.OCT 15/14 REVISED WINDOWS & DOORS AT FRONT WALL (GRID J).
9189
EXTERIOR WALL RATING: OVERALL WEST WALL: ± 471 sq.m. L.D. = ± 32m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS
ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXTERIOR WALL RATING: OVERALL NORTH WALL: ± 535 sq.m. L.D. = ± 44.3m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS
ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
Jerry Lee Consulting Services 4547 - 41st Avenue S.W.
Calgary, Alberta T3E 1G6 Ph: (403) 466 - 3268 [email protected]
Jerry Lee Consulting Services 4547 - 41st Avenue S.W.
Calgary, Alberta T3E 1G6 Ph: (403) 466 - 3268 [email protected]
LINE OF MEZZANINE OVER
MAY 6/15 SHOP W/R ROUGH-INS REV'D; ADDED W/R ROUGH-INS AT OFFICE AREA; SHOP MECH. RM. ADDED; DOORS D7 & D8 ADDED.
DOOR SCHEDULE:
DO
OR
NU
MB
ER
SIZE DO
OR
ELE
V.
MET
AL
ALU
MIN
UM
WO
OD
HO
LLO
W C
OR
E
SOLI
D C
OR
E
INSU
LATE
D
STA
INED
PAIN
TED
PREF
INIS
HED
FULL
GLA
ZIN
G
1/2
GLA
ZIN
G
1/4
GLA
ZIN
G
DOORS FRAMES
FRA
ME
TYPE
FRA
ME
DET
AIL
MET
AL
ALU
MIN
UM
WO
OD
STA
INED
SID
ELIG
HT
PAIN
TED
PREF
INIS
HED
TRA
NSO
M
LOC
KSE
T
DEA
DB
OLT
PASS
AG
ESET
HARDWARE
PRIV
AC
YSET
PUSH
/ PU
LL
PAN
IC S
ET
H/C
OPE
NER
LEVE
RED
HA
ND
LES
FLU
SHB
OLT
SUR
FAC
E B
OLT
AST
RA
GA
L
KIC
KPL
ATE
CLO
SER
DO
OR
STO
P
WEA
THER
STR
IP
THR
ESH
OLD
SWEE
P
REMARKSLOC
ATI
ON
(RO
OM
#)
102
C-L
OC
K W
/ TH
UM
B
FIR
E R
ATI
NG
PRES
SED
STE
EL
HIN
GES
CH
ECK
-CH
AIN
INSU
LATE
D
D1
D3
D4
D5D6D7
914 X 2134 B 2 6
FRAME 1
FRAME TYPEDOOR ELEVS
ELEV. A ELEV. B FRAME 2
3060
2184
D2104
2 HD914 X 2134 B 2 62 HD
101 914 X 2134 A 1 3HD103 914 X 2134 A 1 3HD105
107
914 X 2134
914 X 2134
A 1A 1 3
3 4545
D8108 914 X 2134 A 1 3
FUTURE ELEC. ROOM
LINE OF MEZZANINE OVER
ROUGHED-IN WASHROOMS
EXTERIOR WALL RATING: OVERALL SOUTH WALL: ± 535 sq.m. L.D. = ± 31.8 m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. • NO FIRE RATING REQ'D. • COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION
& CLADDING PERMITTED.
MAY 13/15 FIRE RATING REMOVED FROM WALL ON GRID 7.
FUTURE WAREHOUSE W/R's: FRAME WALLS TO 2700MM HEIGHT. PROVIDE STEEL
STUD FRAMING ACROSS ROOM & PROVIDE 16MM GYPROC CEILING AT ± 2400MM A.F.F.
TYP. OFFICE W/R's: FRAME WALLS TO 2700MM HEIGHT. PROVIDE SUSP. 16MM GYPROC CEILING AT ± 2400MM A.F.F.
RESERVED RESERVED RESERVED
D10
D9
D11
D12
D13
D14
D15
D16
D17
111
113
114
115
116
762 X 2134
914 X 2134
A 1 3 W/R SIGNAGE REQ'D; WOOD DOOR ALT.
A 1 3 W/R SIGNAGE REQ'D; WOOD DOOR ALT.
762 X 2134 A 1 3 W/R SIGNAGE REQ'D; WOOD DOOR ALT.
762 X 2134 A 1 3 W/R SIGNAGE REQ'D; WOOD DOOR ALT.
914 X 2134 A 1 3 W/R SIGNAGE REQ'D; WOOD DOOR ALT.
AUG 19/15 WASHROOMS ADDED TO SCOPE OF WORK; W/R DOORS ADDED TO DOOR SCHEDULE.
GUARDRAIL OR HALF-WALL.
GUARDRAIL OR HALF-WALL.
TRAVEL DISTANCE: 16.8m
WATER TANK WATER TANK BELOW Open Area
± 64 sq.m.
CONC. SLAB CAPACITY IN THIS AREA TO BE CONFIRMED BY STRUCTURAL ENGINEER
FOR MAXIMUM LOAD OF FILLED WATER TANK.
EXTERIOR WALL RATING: OVERALL EAST WALL: ± 471 sq.m. L.D. 3.2.3.10.(2). = > 9.0m TABLE 3.2.3.1.C: > 100% UNPROTECTED
OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING
REQ'D.
FRAME IN ± 300MM HIGH SLOPED ROOF OVER W/R'S & FINISH W/ 13MM GYPROC OVER.
45typ.
officetyp.
office
914 X 2134
813 X 2134A 1 3 OFFICE DOORS A thru' E AT MAIN FLOOR.
OFFICE DOORS A & B AT UPPER FLOOR.A 1 3
Elec. panels
C-4: 152 X 102 X 9.5mm H.S.S. (6 x 4 x 3/8") - RATED FINISH: RATED FINISH NOT REQUIRED AS
COLS ARE NONCOMBUSTIBLE.
LEGEND: U.N.O. UNLESS NOTED OTHERWISE A.F.F. ABOVE FINISHED FLOOR U/S UNDERSIDE T/O TOP OF
G-8
D52
W8CONSTRUCTION NOTES: SHEET A-4.
WINDOW SCHEDULE: A-2.
DOOR TYPE: SHEET A-3.
12
JUNE 16/17 ISSUED FOR REVISED PERMIT; F.D. CONNECTION SHOWN AT EAST WALL; CODE REFERENCE FOR EBF CALC's REVISED.
FUTURE DEMISING WALL AS PER TENANCY DEVELOPMENTS.
WAREHOUSE MECH ROOM; FRAME RATED WALL TO U/S FLOOR OVER.
UPPER FLOOR MECH ROOM; FRAME RATED WALL TO U/S ROOF
OR FRAME WALLS TO ± 2700MM HEIGHT & PROVIDE STEEL STUD FRAMING ACROSS ROOM & PROVIDE 2 LAYERS 16MM TYPE "X" AT UNDERSIDE & 1 LAYER AT TOP SURFACE. - 1 HOUR RATING: ABC Table D2.3.12.
FRAME WALLS TO ± 2700MM HEIGHT & PROVIDE STEEL STUD FRAMING ACROSS
ROOM & PROVIDE 2 LAYERS 16MM TYPE "X" AT UNDERSIDE & 1 LAYER AT TOP SURFACE.
- 1 HOUR RATING: ABC Table D2.3.12.
FUTURE DEMISING WALL AS PER TENANCY DEVELOPMENTS.
FIRE DEPT. CONNECTION
FIRE DEPT CONNECTION TO BE BETWEEN 3.0 & 15M OF PRINCIPAL ENTRANCE WHERE ANNUNCIATOR PANEL IS LOCATED.
X-Bracing as per Struct.X-Br
acin
g ab
ove
as p
er S
truc
t.X-
Brac
ing
abov
e as
per
Str
uct.
X-Bracing as per Struct.
X-Br
acin
g as
per
Str
uct.
X-Br
acin
g as
per
Str
uct.
#101 Tenant #1 Warehouse
CRANE WAREHOUSE
#102 Tenant #1
Office
#201 Tenant Space
#104 Mech. Rm.
#105 Elec. & Phone
#117 Board Room
#109 W/R
#110 W/R
#113 W/R
#115 W/R
#114 W/R
#116 W/R
#111 W/R
#103 Tenant #2 Warehouse
#112 Office
#107 Office
#106 Office
#108 Office
#118 Mech Room
#119 Kitchen
#202 Shop Office
#203 W/R
#204 Mech Rm
#117 Corridor
2990
5486
305
7772
7772
309
5486
2989
345
3839
5
2643
2642
1919
719
198
345
317330
36893 9462
46355
6413 6096 6096 6097 6095 6096 4573 4889
6629
6284
6283
6285
6284
6630
330
9462
4573 4889
6629
6284
6283
6285
6284
6630
3839
5
1829 860
3951
1829
850
1500
1829
1818
1818
1829 1190
1800
± 1728 ± 4623
1219
1219
19 R
UN
S =
532
019
RU
NS
= 5
320
100
100
1219
1219
1192
1829
1760
650
784
3000
1900
1900
± 2350 1600 400
2250
2250
2247
2247
3060
3060
2247
2247
3060
3060
2086
1829
904
1829
1807
1829
3600
2086
1829
904
1829
1807
1829
3600
3100
3150
440
3320
2960
800
3850
1440 3070
± 1490
1900
3770
± 16
85 1800 ± 31
2531
601350970
± 3330 600
1200
BA-4
D-2
D-1
D-4
D-3
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-2 W-2
BA-4
BA-4
BA-4
1 A-4
TYP. STAIR TO MEZZANINE.
1 A-4
TYP. STAIR TO MEZZANINE.
D-5
W-3
W3a
W-3
W-1W-1
W4
W4
W4
D13 D14
D15 D16
W3a
W3a
W4
W4
W4
W2
W4
AA-4
AA-4
AA-4
W3a
W4
W4
4a
W4
4a
W-3
W-3
W-3
W-1
W-3
D-6
D11
W4
W4
W4
W4W4
W4
9A
9B
9C
9D
9E
W4
W4
W4
W4W3
W3
D-8
10A
10B
D12
W4
W4
W4
W4
JUNE 16/17 ISSUED FOR REVISED PERMIT; UPPER WINDOWS REVISED ON EAST ELEV; CODE REFERENCE FOR EBF CALC's REV'D.
APRIL 30/15 ISSUED FOR PERMIT & CONSTRUCTION.
Partial Site Plan Elevations General Details
Revisions:
JOB No.
DATE:
DRAWN:
Drawing Title:
THIS
PLA
N A
ND
DES
IGN
AR
E, A
ND
AT
ALL
TIM
ES R
EMA
IN T
HE
EXC
LUSI
VE P
RO
PER
TY O
F R
ICK
BA
LBI A
RC
HIT
ECT
LTD
. A
ND
CA
NN
OT
BE
USE
D O
R R
EPR
OD
UC
ED W
ITH
OU
T W
RIT
TEN
CO
NSE
NT.
14-214
Sheet A2 of 5
Mechanical:
DO
NO
T SC
ALE
DR
AW
ING
S: A
NY
DIS
CR
EPA
NC
IES
AR
E TO
BE
REP
OR
TED
TO
TH
E A
RC
HIT
ECT
PRIO
R T
O T
HE
CO
MM
ENC
EMEN
T O
F A
NY
WO
RK
Electrical:
Seal:
Site Servicing:
Structural:
Project:
905748 ALBERTA LTD. Box 72154 RPO Glenmore Landing
Calgary, Alberta Ph: (403) 252-7866 Fax: (403) 255-7364
[email protected] (ALSO OPERATING AS PROFESSIONAL PIPE)
SOUTH ELEVATION (Right Side) SCALE: 1 : 150
NORTH ELEVATION (Left Side) SCALE: 1 : 150
WEST ELEVATION (Rear) SCALE: 1 : 150
EAST ELEVATION (Front) SCALE: 1 : 150
118
7 6 5 4 3 2 1
EL. 100.00mGROUND FLOOR
EL. 103.585mMEZZANINE
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
1 4 7
ABCDEFGHJ
A B C D E F G H J
118
3585
1181
610
66
EL. 100.00mGROUND FLOOR
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
1181
610
66
EL. 100.00mGROUND FLOOR
EL. 103.585mMEZZANINE
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
3585
1181
610
66
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
1181
610
66
WAREHOUSE BUILDING "B"
RR 283 & Glenmore Trail S.E.
Calgary, Alberta
Rick Balbi Architect Ltd. #15 -5917 - 1"A" Street S.W. Calgary, Alberta T2H 0G4
Ph: (403) 253 - 2853 Fax: (403) 253 - 3078 [email protected]
APPROXIMATE LINE OF CROSS-BRACING AS PER STRUCT. DWGS.
APPROXIMATE LINE OF CROSS-BRACING AS PER STRUCT. DWGS.
± 20
30
1829 X 1067MM
1219
ROUNDED FINISH TO TOP OF CONC. FILL.
200MM Ø STEEL PIPE FILLED W/ CONC. - PAINT EXTERIOR FOR VISIBILITY.
CONC. APRON.
300MM Ø POURED CONC. IN SONOTUBE.
1219
BOLLARD DETAIL SCALE: 1 : 20
1 A-2
TYPICAL BOLLARD DETAIL.
ROOF HATCH DETAIL SCALE: 3/4" = 1'-0"2
COUNTER FLASHINGMETAL CURB W/ RIGID INSUL.
FRAMING AROUND OPENING AS PER STRUCTURAL.CONFIRM UNIT OPENINGPROVIDE FRAMING
AROUND PERIMETER OF OPENING.
FLASHING OVER EDGE OF ROOF PANEL (TO MATCH).
PRE-ENG. BUILDING SHELL C/W INSUL. BLANKET.
24" x 36" SINGLE LEAF ROOF HATCH ("CURBER") W/ INSUL. ALUM. COVER & GALV. STEEL CURB,
DRAFT SEAL, SPRING LATCH w/ INSIDE RELEASE & PADLOCK EYE.
AIR HYDRAULIC CYLINDER W/ LOCKABLE LATCH.
1
EL. 100.00mGROUND FLOOR
July 15, 2014
SF / LM
1 24 Ga. PREFINSHED METAL WALL CLADDING. - WHITE-WHITE TYPICAL.
2
400W METAL HALIDE WALL-PACK SECURITY LIGHT. - TYP. OVER OH DOOR
100W METAL HALIDE DOOR LIGHT TYP.
3
4
EXTERIOR FINISH
24 Ga. PREFINSHED METAL ROOF CLADDING. - WHITE-WHITE TYPICAL.
FIXED WINDOW W/ CLEAR ALUM. FRAME & CLEAR LOW "E GLAZING.5
METAL DOOR & FRAME PAINTED TO MATCH METAL SIDING.6
PREFINISHED STOREFRONT DOOR W/ CLEAR ALUM. FRAME & CLEAR LOW "E" GLAZING.7
PREFINISHED 24 ga METAL GUTTER TO MATCH ROOF CLADDING C/W DOWNSPOUTS TO GRADE.
8
STEEL PIPE BOLLARD C/W CONC. FILL & PAINT FINISH FOR VISIBILITY.9
EA
ST
SID
E P
RO
PE
RTY
BO
UN
DA
RY
RA
NG
E R
OA
D 2
83
3839
5
46355
EXTERIOR WALL RATING: OVERALL WEST WALL: ± 471 sq.m. L.D. = ± 32m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
22800
EXTERIOR WALL RATING: OVERALL EAST WALL: ± 471 sq.m. L.D. 3.2.3.10.(2). = > 9.0m
TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXISTING WAREHOUSE
EXISTING WAREHOUSE
H I
EXISTING 22' X 20'
O.H. DOOR
EXISTING 16' X 18'
O.H. DOOR
EXISTING 22' X 20'
O.H. DOOR
PARTIAL SITE PLAN SCALE: 1 : 300
EXISTING EXTERIOR WALL 1 HR RATING: OVERALL NORTH WALL, BUILDING "J": ± 121.7 sq.m. EXISTING UNPROTECTED OPENINGS: ±23.3 sq.m. (19%) L.D. = ± 5.2 m TABLE 3.2.3.1.A: ±19% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: 1 HR. F.R.R. REQ. COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION. NON-COMBUSTIBLE CLADDING. LINE OF LIMITING DISTANCE
JExist. Office
EXISTING 2 HR FIREWALL
1410
0
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "H": ± 111.3 sq.m.
EXISTING UNPROTECTED OPENINGS: ±40.9 sq.m. (36.7%) L.D. = ± 14.1 m
TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "H": ± 111.3 sq.m. EXISTING UNPROTECTED OPENINGS: ±40.9 sq.m. (36.7%) L.D. = ± 14.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
1410
0
1210
0
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "I": ± 87.5 sq.m. EXISTING UNPROTECTED OPENINGS: ±28.7 sq.m. (32.8%) L.D. = ± 12.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
1410
0
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "I": ± 29.3 sq.m. L.D. = ± 9.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "I": ± 122.2 sq.m. L.D. = ± 14.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
9100
PROPOSED WAREHOUSE BUILDING ± 1779.8 sq.m.
MAIN FLOOR ELEV. = T.B.C.
EXTERIOR WALL RATING: OVERALL NORTH WALL: ± 535 sq.m. L.D. = ± 42.0m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
5200
EXTERIOR WALL RATING: OVERALL SOUTH WALL: ± 535 sq.m. L.D. = ± 31.8 m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. • NO FIRE RATING REQ'D. • COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION
& CLADDING PERMITTED.
± 42
867
± 31
800
2030
WINDOW SCHEDULETYPICAL EXTERIOR WINDOW: - CLEAR ALUM. FRAME; THERMALLY BROKEN. - CLEAR LOW-E GLAZING.
G-1
G-23060 X 2184MM
OCT 15/14 REVISED WINDOWS & DOORS AT FRONT WALL (GRID J).
± 20
30
NON-ILLUMINATED SIGNAGE.10
Building B
Jerry Lee Consulting Services 4547 - 41st Avenue S.W.
Calgary, Alberta T3E 1G6 Ph: (403) 466 - 3268 [email protected]
Jerry Lee Consulting Services 4547 - 41st Avenue S.W.
Calgary, Alberta T3E 1G6 Ph: (403) 466 - 3268 [email protected]
SEPTIC HOLDING TANK -SEE MECHANICAL DWGS.
NEW TRANSFORMER.
UNDERGROUND WATER HOLDING TANK.
MAY 6/15 REVISED LOCATIONS FOR SEPTIC & WATER TANKS & TRANSFORMER AT BUILDING "B".
MAY 13/15 EBF INFORMATION REVISED AS PER UPDATED L.D. DIMS.
LEGEND: U.N.O. UNLESS NOTED OTHERWISE A.F.F. ABOVE FINISHED FLOOR U/S UNDERSIDE T/O TOP OF
G-8
D52
W8CONSTRUCTION NOTES: SHEET A-4.
WINDOW SCHEDULE: A-2.
DOOR TYPE: SHEET A-3.
12
FIRE DEPT CONNECTION. - FINAL LOCATION TO BE CONFIRMED. - TO BE BETWEEN 3.0 & 15M OF PRINCIPAL ENTRANCE & WITHIN 45M OF HYDRANT.
F.H. LOCATION TO BE CONFIRMED BY OTHERS.
1
1
2 1
2
4
3
4
5
5
5
6
77
1
8
8
8
9 6
8
10
G-1G-1G-1G-1G-1G-1
G-1
G-1
G-1G-1G-1
JUNE 16/17 ISSUED FOR REVISED PERMIT; UPPER WINDOWS REVISED ON EAST ELEV; CODE REFERENCE FOR EBF CALC's REV'D.
APRIL 30/15 ISSUED FOR PERMIT & CONSTRUCTION.
Partial Site Plan Elevations General Details
Revisions:
JOB No.
DATE:
DRAWN:
Drawing Title:
THIS
PLA
N A
ND
DES
IGN
AR
E, A
ND
AT
ALL
TIM
ES R
EMA
IN T
HE
EXC
LUSI
VE P
RO
PER
TY O
F R
ICK
BA
LBI A
RC
HIT
ECT
LTD
. A
ND
CA
NN
OT
BE
USE
D O
R R
EPR
OD
UC
ED W
ITH
OU
T W
RIT
TEN
CO
NSE
NT.
14-214
Sheet A2 of 5
Mechanical:
DO
NO
T SC
ALE
DR
AW
ING
S: A
NY
DIS
CR
EPA
NC
IES
AR
E TO
BE
REP
OR
TED
TO
TH
E A
RC
HIT
ECT
PRIO
R T
O T
HE
CO
MM
ENC
EMEN
T O
F A
NY
WO
RK
Electrical:
Seal:
Site Servicing:
Structural:
Project:
905748 ALBERTA LTD. Box 72154 RPO Glenmore Landing
Calgary, Alberta Ph: (403) 252-7866 Fax: (403) 255-7364
[email protected] (ALSO OPERATING AS PROFESSIONAL PIPE)
SOUTH ELEVATION (Right Side) SCALE: 1 : 150
NORTH ELEVATION (Left Side) SCALE: 1 : 150
WEST ELEVATION (Rear) SCALE: 1 : 150
EAST ELEVATION (Front) SCALE: 1 : 150
118
7 6 5 4 3 2 1
EL. 100.00mGROUND FLOOR
EL. 103.585mMEZZANINE
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
1 4 7
ABCDEFGHJ
A B C D E F G H J
118
3585
1181
610
66
EL. 100.00mGROUND FLOOR
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
1181
610
66
EL. 100.00mGROUND FLOOR
EL. 103.585mMEZZANINE
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
3585
1181
610
66
EL. 111.816mLOW EAVE
EL. 112.882mROOF PEAK
1181
610
66
WAREHOUSE BUILDING "B"
RR 283 & Glenmore Trail S.E.
Calgary, Alberta
Rick Balbi Architect Ltd. #15 -5917 - 1"A" Street S.W. Calgary, Alberta T2H 0G4
Ph: (403) 253 - 2853 Fax: (403) 253 - 3078 [email protected]
APPROXIMATE LINE OF CROSS-BRACING AS PER STRUCT. DWGS.
APPROXIMATE LINE OF CROSS-BRACING AS PER STRUCT. DWGS.
± 20
30
1829 X 1067MM
1219
ROUNDED FINISH TO TOP OF CONC. FILL.
200MM Ø STEEL PIPE FILLED W/ CONC. - PAINT EXTERIOR FOR VISIBILITY.
CONC. APRON.
300MM Ø POURED CONC. IN SONOTUBE.
1219
BOLLARD DETAIL SCALE: 1 : 20
1 A-2
TYPICAL BOLLARD DETAIL.
ROOF HATCH DETAIL SCALE: 3/4" = 1'-0"2
COUNTER FLASHINGMETAL CURB W/ RIGID INSUL.
FRAMING AROUND OPENING AS PER STRUCTURAL.CONFIRM UNIT OPENINGPROVIDE FRAMING
AROUND PERIMETER OF OPENING.
FLASHING OVER EDGE OF ROOF PANEL (TO MATCH).
PRE-ENG. BUILDING SHELL C/W INSUL. BLANKET.
24" x 36" SINGLE LEAF ROOF HATCH ("CURBER") W/ INSUL. ALUM. COVER & GALV. STEEL CURB,
DRAFT SEAL, SPRING LATCH w/ INSIDE RELEASE & PADLOCK EYE.
AIR HYDRAULIC CYLINDER W/ LOCKABLE LATCH.
1
EL. 100.00mGROUND FLOOR
July 15, 2014
SF / LM
1 24 Ga. PREFINSHED METAL WALL CLADDING. - WHITE-WHITE TYPICAL.
2
400W METAL HALIDE WALL-PACK SECURITY LIGHT. - TYP. OVER OH DOOR
100W METAL HALIDE DOOR LIGHT TYP.
3
4
EXTERIOR FINISH
24 Ga. PREFINSHED METAL ROOF CLADDING. - WHITE-WHITE TYPICAL.
FIXED WINDOW W/ CLEAR ALUM. FRAME & CLEAR LOW "E GLAZING.5
METAL DOOR & FRAME PAINTED TO MATCH METAL SIDING.6
PREFINISHED STOREFRONT DOOR W/ CLEAR ALUM. FRAME & CLEAR LOW "E" GLAZING.7
PREFINISHED 24 ga METAL GUTTER TO MATCH ROOF CLADDING C/W DOWNSPOUTS TO GRADE.
8
STEEL PIPE BOLLARD C/W CONC. FILL & PAINT FINISH FOR VISIBILITY.9
EA
ST
SID
E P
RO
PE
RTY
BO
UN
DA
RY
RA
NG
E R
OA
D 2
83
3839
5
46355
EXTERIOR WALL RATING: OVERALL WEST WALL: ± 471 sq.m. L.D. = ± 32m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
22800
EXTERIOR WALL RATING: OVERALL EAST WALL: ± 471 sq.m. L.D. 3.2.3.10.(2). = > 9.0m
TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXISTING WAREHOUSE
EXISTING WAREHOUSE
H I
EXISTING 22' X 20'
O.H. DOOR
EXISTING 16' X 18'
O.H. DOOR
EXISTING 22' X 20'
O.H. DOOR
PARTIAL SITE PLAN SCALE: 1 : 300
EXISTING EXTERIOR WALL 1 HR RATING: OVERALL NORTH WALL, BUILDING "J": ± 121.7 sq.m. EXISTING UNPROTECTED OPENINGS: ±23.3 sq.m. (19%) L.D. = ± 5.2 m TABLE 3.2.3.1.A: ±19% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: 1 HR. F.R.R. REQ. COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION. NON-COMBUSTIBLE CLADDING. LINE OF LIMITING DISTANCE
JExist. Office
EXISTING 2 HR FIREWALL
1410
0
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "H": ± 111.3 sq.m.
EXISTING UNPROTECTED OPENINGS: ±40.9 sq.m. (36.7%) L.D. = ± 14.1 m
TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "H": ± 111.3 sq.m. EXISTING UNPROTECTED OPENINGS: ±40.9 sq.m. (36.7%) L.D. = ± 14.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
1410
0
1210
0
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "I": ± 87.5 sq.m. EXISTING UNPROTECTED OPENINGS: ±28.7 sq.m. (32.8%) L.D. = ± 12.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
1410
0
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "I": ± 29.3 sq.m. L.D. = ± 9.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
EXISTING EXTERIOR WALL RATING: PARTIAL NORTH WALL, BUILDING "I": ± 122.2 sq.m. L.D. = ± 14.1 m TABLE 3.2.3.1.A: >100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
9100
PROPOSED WAREHOUSE BUILDING ± 1779.8 sq.m.
MAIN FLOOR ELEV. = T.B.C.
EXTERIOR WALL RATING: OVERALL NORTH WALL: ± 535 sq.m. L.D. = ± 42.0m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. 3.2.3.7: NO FIRE RESISTANCE RATING REQ'D.
5200
EXTERIOR WALL RATING: OVERALL SOUTH WALL: ± 535 sq.m. L.D. = ± 31.8 m TABLE 3.2.3.1.C: > 100% UNPROTECTED OPENINGS ALLOWED. • NO FIRE RATING REQ'D. • COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION
& CLADDING PERMITTED.
± 42
867
± 31
800
2030
WINDOW SCHEDULETYPICAL EXTERIOR WINDOW: - CLEAR ALUM. FRAME; THERMALLY BROKEN. - CLEAR LOW-E GLAZING.
G-1
G-23060 X 2184MM
OCT 15/14 REVISED WINDOWS & DOORS AT FRONT WALL (GRID J).
± 20
30
NON-ILLUMINATED SIGNAGE.10
Building B
Jerry Lee Consulting Services 4547 - 41st Avenue S.W.
Calgary, Alberta T3E 1G6 Ph: (403) 466 - 3268 [email protected]
Jerry Lee Consulting Services 4547 - 41st Avenue S.W.
Calgary, Alberta T3E 1G6 Ph: (403) 466 - 3268 [email protected]
SEPTIC HOLDING TANK -SEE MECHANICAL DWGS.
NEW TRANSFORMER.
UNDERGROUND WATER HOLDING TANK.
MAY 6/15 REVISED LOCATIONS FOR SEPTIC & WATER TANKS & TRANSFORMER AT BUILDING "B".
MAY 13/15 EBF INFORMATION REVISED AS PER UPDATED L.D. DIMS.
LEGEND: U.N.O. UNLESS NOTED OTHERWISE A.F.F. ABOVE FINISHED FLOOR U/S UNDERSIDE T/O TOP OF
G-8
D52
W8CONSTRUCTION NOTES: SHEET A-4.
WINDOW SCHEDULE: A-2.
DOOR TYPE: SHEET A-3.
12
FIRE DEPT CONNECTION. - FINAL LOCATION TO BE CONFIRMED. - TO BE BETWEEN 3.0 & 15M OF PRINCIPAL ENTRANCE & WITHIN 45M OF HYDRANT.
F.H. LOCATION TO BE CONFIRMED BY OTHERS.
1
1
2 1
2
4
3
4
5
5
5
6
77
1
8
8
8
9 6
8
10
G-1G-1G-1G-1G-1G-1
G-1
G-1
G-1G-1G-1
Main Floor Plan Mezzanine
West Real Estate - Industrial YYC
IND
UST
RIA
L
CBCWestRealEstate.ca industrialYYC.com
FOR LEASE233167 RANGE ROAD 283 - BUILDING L
IND
UST
RIA
L
Kaile Landry403.669.3050
Jason Duncan403.471.7690
Mark Bizek403.615.5725
233167 Range Road 283
Glenmore Trail SEGlenmore Trail SE
114 Avenue SE
4 min drive to Stoney Trail SE
Ston
ey T
rail
SE
SHEPARD INDUSTRIAL
SOUTH FOOTHILLS
52 S
tree
t SE
N