User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 | fax 503.651.5052 | email [email protected] | www.vatainc.com
Transcript
Page 1: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

User Manual

2365/2366 Advanced Venipuncture Training Aid™

308 South Sequoia Parkway, Canby, Oregon 97013 USAph. 503.651.5050 | fax 503.651.5052 | email [email protected] | www.vatainc.com

Page 2: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

Thank you for your purchase of VATA’s - 2365/2366 Advanced Venipuncture Training Aid™

This model is now made with two of VATA’s newly developed materials, Dermalike II™ and Dermalike V™. The vein pad is made with Dermalike II™, and when used accord-ing to the instructions, offers many unique and improved properties.Some of the properties are:• Themodelisratedfor2400needleaccesses,thoughcustomershavereportedtheir

experienceis2-3timesthisnumber• 60% less needle drag when puncturing, which results in amuchmore realistic

experience• Improvedtearresistance,extendingtheusefullifeoftheproduct• Feelsandpalpateslikehumantissueforamorerealisticlearningexperience• Stainresistant

The veins are made of VATA’s latex free Dermalike V™. This material has properties moresimilartorealveinscomparedtothelatextubingpreviouslyusedonouroriginalAdvancedVenipuntureTrainingAidandstillbeingusedbyothermanufacturers.

The 2365 Advanced Venipuncture Training Aid™ features fourbarelydiscernableblueveinsof3differentdiameters–with the fourthveindeeplyplaced– inasemi-transparent,tissue-likepad.Whenaccessingarealistic“flashback”ofsimulatedbloodconfirmstheproperneedleplacement.Anoptionalcarryingcase,withstoragepouchforsupplies,isavailable(seepage10,0385).

PleasereadtheentireUser’sManualcarefullybeforeusingthemodeltoensurethatyou understand the proper care and use of this device. This will also avoid situations thatmaynotbecoveredbythewarranty,andhelpyoutoenjoythemaximumbenefits.

With exceptional “true to life” feel when accessing and the elimination of potentialreactions for those with latex sensitivity, this is a truly welcomed advancement in anatomical teaching models.

We understand that cost and useful life are important concerns when selecting teaching models.Wearepleasedtoofferarefurbishingservicetorestorethemodeltolike-newcondition(seepage8).

As always we welcome your suggestions and comments concerning ourproducts,asmanysignificant improvementsandnewproductideashavebeentheresultofourcustomers’suggestions.

To view our informational video on this product go to: www.vatainc.com/2365video

1

Thank You For Your Purchase!

Page 3: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

Product Components1 Base2 Vein pad of Dermalike II™3 Hinged cover plate for vein pad4 BubbleTrapWhiteCap5 BubbleTrap6 Blood Bag with

Simulated Blood7 Stopcock

1

3

6

4

5

2

7

2366DarklyPigmented

2

Page 4: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

Helpful Hints• Bychangingtheaccesslocationeachtimeandusingasharpnon-burred22gIVCatheter,youcanaccessthe2365model2400times,thoughcustomershavereportedtheirexperienceis2-3timesthisnumber.

• Do not place the Dermalike II™ vein pad in contact with productsmade ofvinylorPVCforprolongedperiodsoftime,asthechemicalsinthemwillcausedegradation of the vein pad.

• Storeflat toavoiddeformation.Checkthatstopcock,bubble trapandbubbletrapcaparesecurelyinplacebeforeclosingcover.Donotstorewithitemsontop of the vein pad as it will take on the impression permanently. Always store with the cover in place over the Dermalike II™ vein pad.

• Therearefourveinsofthreedifferentsizesinthemodel.Thefrontareaofthebasedisplaysfourredcirclesthatarethesamesizeastheinsidediametersoftheveinsforvisualizationofthespaceswhenaccessing.Thelargeveinontheleft is deeply placed. Though the veins may visually appear large, accessing andgettingaflashbackcanbemorechallenging.

• Allveinswillproducearealistic“flashback”whenaccessed.

• ThetissuepadofDermalikeII™isstainresistant.

• Thelifeoftheveinswillbemaximizedbytheuseof20gneedlesinthelargeandmediumveins.Thesmallveinshouldbeaccessedwitha24gorsmallerneedle.

• Avoid theuseofdull orburredneedlesas thesewill damage theveinsandcause premature leakage.

• Dependingonuse,overtime,itmaybecomenecessarytoreplacetheveinpadandveinsofthemodel.ThiscanbedonebycontactingVATACustomerServiceforourrefurbishingservice.

• Thesimulatedbloodprovidedisonlyforuseinmodelsandisnotintendedforanyotheruse.Wedonot recommendusingsimulatedblood item2491and2494withthismodel.

• Oursimulatedblood isstain resistant.Forbest results, rinse fabricwithcoldwaterassoonaspossibleaftercomingincontactwithsimulatedblood.

• Cleaningoftheveinpadisbestdonebywipingwithanalcoholwetted,non-lintingcloth.Thepadshouldbepermitted toairdryand thenpowderedwithcornstarchbabytalc.Anyexcesstalccanberemovedwithadrycloth.Ifatanytimetheveinpadbecomestackytothetouch,talcshouldbeapplied.

3

Page 5: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

1. Placefingerontabandpushintoopen hinged cover.

2. Opencovertoavertical position untilanaudible“click”isheard,confirmingthetop is in the locked position.

3. Removebubbletrapfromholder.

4. Unscrewcapandreplacebubbletrapinto holder.

Set-up Instructions

4

Page 6: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com5

5. Turnhandleonstopcocktoaverticalposition;modelwillprimeinunder1minute.

6. Modelisprimedwhensimulatedbloodisvisibleinthebottomofthebubbletrap. If model does not prime see next step.

7. If model does not prime automatically, applylightpressuretosimulatedbloodbagtostartthepriming.

Set-up Instructions, Cont.

Page 7: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

1. Removestopcockfromthecover.

2. Removethesimulatedbloodbagfromthe hook on the cover.

3. Placesimulatedbloodbagbelowthelevel of the vein pad and simulatedbloodwilldrainfromthemodelinunder1minute.

4. Drainingiscompletewhennobloodisseenflowingthroughstopcock.

Storing Instructions

6

Page 8: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

5. Whenthemodeliscompletelydrained, turn the handle on thestopcocktoahorizontalposition.

6. Placethesimulatedbloodbagbackonto the hook in the cover.

7. Snapthestopcockbackintotheholder–anaudible“click”willconfirmproper placement.

8. Removebubbletrapfromcover.

Storing Instructions, Cont.

7

Page 9: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com 8

9. Screwcapbackontothebubbletrap.

10.Snapbubbletrapintoholder–anaudible“snap”willconfirmproperplacement.

11.Stabilizebaseandapplyclosingpressure to cover to release from thelockedposition–anaudible“click”willconfirmdisengagement.

12.Anaudible“click”willbeheardwhen the cover isproperly closed.

Storing Instructions, Cont.

Page 10: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com9

The model is supplied with a simulated bloodbagcontaining80cc.

Whensimulatedbloodneedstobeaddedtothebag,closethestopcockbyturningtoahorizontalposition.Removebagfromhook in cover. Position the needleless adapter in a superior position. Attach the prefilledsyringetotheneedlelessadapterandinfusethesimulatedblood.Repeatasneeded

Should you wish to remove air from the bag, close the stopcock by turning to ahorizontal position. Remove bag fromhook in cover. Position the needleless adapter in a superior position. Attach the syringe to the needleless adaptor and withdrawair.Repeatasneeded.

Care & Filling of Simulated Blood Bag

Page 11: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

www.vatainc.com

Product # Description2365 Advanced Venipuncture Training Aid™

2366 Advanced Venipuncture Training Aid™Darkly Pigmented

0385 OptionalCarryingCaseforitems2365&2366

2367 SimulatedBloodReservoir–withStopcock

1491 SimulatedBlood,OneQuart–StainResistant

1494 SimulatedBlood,OneGallon–StainResistant

Thefollowingitemsareavailableforpurchasewithoutreturningyourmodel.Additionalreplacementpartsareavailableatwww.vatainc.com.

Refurbishing Service Thepurchaseof trainingmodels is a significant financial investment.Realizingthis, VATAisproudtoofferarefurbishingservicetobringyourmodeltolike-newcondition. Please call VATA Customer Service for instructions on how to return yourmodel.Once yourmodel is received, it will be evaluated and youwill becontactedtoapprovethecostofrefurbishingbeforeanyworkisperformed.Turn-aroundtimetocompletearefurbishingislessthanoneweek.

10

2365/2366 Models & Parts

Page 12: 2365/2366 Advanced Venipuncture Training Aid™...User Manual 2365/2366 Advanced Venipuncture Training Aid™ 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 |

200219

You might also like...

308 South Sequoia Parkway, Canby, Oregon 97013 USAph. 503.651.5050 | fax 503.651.5052 | email [email protected] | www.vatainc.com

1352-Two-VeinVenipunctureTrainingAid-DermalikeII™ 1353-Two-VeinVenipunctureTrainingAid,DarklyPigmented-DermalikeII™

1354-Four-VeinVenipunctureTrainingAid-DermalikeII™ 1355-Four-VeinVenipunctureTrainingAid,DarklyPigmented-DermalikeII™

2400-ChesterChest™WithNewAdvancedArm 2402-ChesterChest™WithNewAdvancedArm-DarklyPigmented

1352

1354

2400 2402

1355

1353