+ All Categories
Home > Documents > 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Date post: 16-Nov-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
18
24 th & 25 th May 2018 – Senskin - Istanbul Structural Health Monitoring with AE
Transcript
Page 1: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

24th & 25th May 2018 – Senskin - Istanbul

Structural Health Monitoring with AE

Page 2: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Summary

• Introduction to Mistras

• Structural Health Monitoring Systems (SHMS)

• Acoustic Emissions (AE) summary

• Monitoring for wire breaks

• Conclusions

© Mistras 2018

Page 3: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

www.mistrasgroup.co.uk

750+750+EMPLOYEES IN EUROPEEMPLOYEES IN EUROPE

2222 IN EUROPEIN EUROPE

About MISTRAS

© Mistras 2018

Page 4: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Mistras European Offices

© Mistras 2018

Page 5: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

www.mistrasgroup.co.uk

About MISTRAS

© Mistras 2018

Page 6: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Technologies - Structural Health Monitoring Systems

• 2, 4, 8, 16, 32, 56, 64, 128 and 256 independent channel systems• <100Hz sample rate• Various IP rated cabinets • Virtually any sensor – AE, strain, vibration, tilt, displacement, weather station, GPS etc• Integration of IP systems and total stations/GPS • Long cable lengths, 1km+ (4-20ma current loop)• Power solutions (fuel cell/hybrid diesel/solar)• Remote wireless networks (4G/3G enabled/Satellite broadband) • Temperature correction (software)

© Mistras 2018

4 sensors

8 < 32 sensors

32 < 256 sensors

<56 sensors

Page 7: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Technologies - Structural Health Monitoring Operation

© Mistras 2018

Acquisition• Normal operation – SHMS and AE• Automatic wire break detection• High SHMS speed trigger file operation• Stress analysis• Viaduct bearing monitoring function & structural computation (e.g. buckling)

Data Transfer• Conventional network (CAT6e, FO), DSC or SCADA (Modbus RS-232, RS-485 or TCP/IP) • Remote wireless networks (4G/3G enabled/Satellite broadband)

Data Storage• Local servers ASCI and SQL databases• Web based cloud data storage service

Data Analysis / Process• Noesis / SMS-R / SQL query

Data Visualisation• SCADA dash board interface / Web interface

SHM data in ASCI table

Cloud based results

Page 8: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Wire Break Problem

Hidden defect, requiring invasive inspection or non-invasive technique

© Mistras 2018

Page 9: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Acoustic Emission Summary

© Mistras 2018

Page 10: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Wire Break Research and Validation

© Mistras 2018

Full scale instrumented cable in environmental chamber

Mistras Sensor Highway monitoring system

Page 11: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Integrated AE and Structural Health Systems on Suspension Bridges

© Mistras 2018

Page 12: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Structural Monitoring Cloud – Real Time Results

© Mistras 2018

Page 13: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Structural Monitoring Cloud – Real Time Results

© Mistras 2018

Page 14: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Mistras AE and SHM System Verification

23rd June 2008- Unwrapping of cable and removal of circumferential wrap- 900mm wire wrapping removed from 1150mm to 2050mm above CB10- Shift finishes, workers leave site

© Mistras 2018

Cable after opening

Page 15: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Mistras AE and SHM System Verification

23rd June 2008- Unwrapping of cable and removal of circumferential wrap- 900mm wire wrapping removed from 1150mm to 2050mm above CB10- Shift finishes, workers leave site- Mistras AEM system automatically detects wire break on 23/06/08 22:39:41hrs at 1151.17m

downstream, 1480mm from cable clamp CB10 towards cable clamp CB9D

© Mistras 2018

Wire break signal at first sensor

Wire break automatically located on the main cable

Page 16: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

24th June 2008- Inspection of unwrapped cable found additional wire broken 23R at 1420mm

from CB10 at 1151.11m on cable length

- Location verified to within 60mm of MISTRAS AEM system calculated location

Mistras AE and SHM System Verification

© Mistras 2018 Broken wire found at the start of the shift

Automated wire break location

Page 17: 24 & 25 May 2018 –Senskin -Istanbul Structural Health ...

Conclusion

• Acoustic Emission as SHM is a very effective technique for detecting hidden defects

• The AE application for wire break detection is very mature now, with Mistras detecting over 1,400 wire breaks (to date) over 93 cumulative years of monitoring

• When properly specified, installed and maintained SHM systems can be functional in excess of 20 years+

• AE and structural health monitoring is a powerful tool for bridge owners to assist in asset management and safe operations

SHM installation on Humber Suspension Bridge main cable