Controller Card for 240VAC Motors used on Light Commercial Doors, Industrial Roller Shutters,
Sectional Doors, Garage Doors, Sliding Doors and Swing Gates
VERSION 3
www.elsema.com
240S1240S2
2 Controller Card for 240VAC Motors
Features• Adjustableautoclose• Adjustableslowspeedforopenandclose• Deadmancontrolsforopenandcloseinputs• Automaticgroundandtraveldistancecalibration• Photocell,pedestrianandwirelessremotecontrolinputs• Externalkeyswitchforsafetyandsecurity(Onlyon240S2)• SupportsNCorNOlimitswitchinputsortraveltimersetup• Auxrelayoutputtocontrolcourtesylightsandotheraccessories• 24VDCoutputtosupplyexternalaccessoriessuchasloopdetectors,swipecardsetc• Toroidaltransformerforexcellentefficiencyandlowleakagelossesreducingyourelectricity
consumption.DynamicPowerSavings• Customisedmodelsavailableuponrequest,120S1and120S2forinternationalmarkets
DescriptionThe240S1and240S2areverysimilarcardsexceptforthecardsizeandthe240S2hasakeyswitchinput.Offeringtwodifferentsizesallowsthecardstobeeasilyinstalledintoexistingcasesasreplacementorupgradecards.Thesetwocardsareoneofourbestvaluedcardsonthemarket,sellingforaverycompetitiveprice,yetstillloadedwithmanyfeatures.Thecontrolcardswerebuiltfromthegroundup,basedoncustomerfeedbackandusingtoday’stechnology.Withitsrichfunctions,consumerfriendlypriceandwiththefocusduringdevelopmentbeingeaseofuseandsetupmakesthese240VACcontrolcardstheultimateboardtocontrolyourmotors.Atoroidaltransformerisusedtopowerthecontrolcardandcontactors.Usingatoroidaltransformeroffersthefollowingadvantages:• Excellentefficiencyandlowleakagelossesreducingyourelectricityconsumption• Highisolationwhichprotectstheelectronicsfromnoisypowerlines• LowmagneticfieldradiationandnoacousticnoiseenablingthecontrollertopassEMCandother
stringentradiationtests
Allinstallationsandtestingmustbedoneonlyafterreadingandunderstandingallinstructionscarefully.Allwiringsshouldbedoneonlybytrainedtechnicalpersonnel.Failingtofollowinstructionsandthesafetywarningsmayresultinseriousinjuryand/ordamagetoproperty.ElsemaPtyLtdshallnotbeliableforanyinjury,damage,cost,expenseoranyclaimwhatsoevertoanypersonorpropertywhichmayresultfromimproperuseorinstallationofthisproduct.
Important warning and safety instructions
3www.elsema.com
Part Numbers:Part Number Description Application
240S1E
The240S1EisenclosedinacompactIP66ratedplasticenclosure.CaseSize:175x175x75mm
120S1E-120VACversionforinternationalmarketswith120VACVoltage
LightCommercialDoors,IndustrialRollerShutters,SectionalDoors,GarageDoors,SlidingDoorsand
SwingGates
240S2E
The240S2EisenclosedinaIP66ratedplasticenclosurewithUP/DOWN/STOPexternalpushbuttons.
120S2E-120VACversionforinternationalmarketswith120VACVoltage
LightCommercialDoors,IndustrialRollerShutters,SectionalDoors,GarageDoors,SlidingDoorsand
SwingGates
240S2EK
The240S2EKisenclosedinaIP66ratedplasticenclosurewithUP/DOWN/STOPexternalpushbuttonsandkeyswitchforextrasecurityandsafety.
120S2EK-120VACversionforinternationalmarketswith120VACVoltage
LightCommercialDoors,IndustrialRollerShutters,SectionalDoors,GarageDoors,SlidingDoorsand
SwingGates
240S1
The240S1controlcardonlywithboardsizeof148x92mm.
120S1-120VACversionforinternationalmarketswith120VACVoltage
Replacementorupgradecontrollercardfor240VACMotors
240S2
The240S2controlcardonlywithboardsizeof148x120mmandkeyswitchinput.
120S2-120VACversionforinternationalmarketswith120VACVoltage
Replacementorupgradecontrollercardfor240VACMotors
Allthesecontrollersaresuitableformotorsupto1.5kW(2.0Hp).
Riskinthegoodspurchasedshallunlessotherwiseagreedinwrittenpasstothebuyerupondeliveryofthegoods.Anyfiguresorestimatesgivenforperformanceofgoodsarebaseduponthecompany’sexperienceandiswhatthecompanyobtainsontests.ThecompanywillnotacceptliabilityforfailuretocomplywiththefiguresorestimatesduetothenatureofvariableconditionsaffectingforexampleRadioRemoteControls.Pleasekeepthissetupinstructionforfuturereference.
4 Controller Card for 240VAC Motors
Block Diagram 240S1
5www.elsema.com
240VAC Supply Supplyconnectiontopowerthe240S1andthemotor
Open MotorOPENdirectionterminal
Close MotorCLOSEdirectionterminal
Neutral Motorneutralterminal
Motor Capacitor Motorcapacitorterminal
Auxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpen
Limit Switch Open &Common
Iflimitswitchesareusedconnectthemtothisterminal.FactoryDefaultNormallyClosed
Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal
Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.
Open OnlyUsedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoorcannotbeclosed.Holdingthisinputwillpreventclosing.NormallyOpeninput.
Close OnlyUsedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoorcannotbeopened.Holdingthisinputwillpreventopening.NormallyOpeninput.
CommonCommonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stopandpedestrianaccess.
StopUsedtoconnectanexternalpushbuttontostopthegateordoor.Holdingthisinputwillpreventthegateordoorfromopeningorclosing.NormallyOpeninput.
Pedestrian AccessUsedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.NormallyOpeninput.
Photo Electric BeamUsedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.UsercanchangetoNormallyOpen.
DC Output24VDC/150mA.Usetosupplyaccessories.(UseElsemaReg12toconvertthisoutputto12VDC)
Slide Switch Usedtoaccessthecontrolcardfeatures.Input Status LEDs Indicatesinputsstatus.
Tact Switches
TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.A=PushButtonB=OpenOnlyC=CloseOnlyD=StopE=PedestrianAccess
Auto Close trimpot UsedtoadjusttheAutoClosetime.Dip Switch Usedtoaccessthecontrolcardfeatures.Open, Close LEDs IndicatesOpeningorClosingcycle.Enter button Usedtochangefeaturesinprogrammingmode.
ReceiverUsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.UseElsema’sPentacodeseries.
Antenna Usedtoconnectanexternalantennaforthepluginreceiver.Buzzer Indicatesthatchangeoffeatureswassuccessful.
FuseSlowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW(1.3HP).
6 Controller Card for 240VAC Motors
Relay
AB
CD
18
ON
27
65
43
RU
N
Prog1
Prog2
E
FUSE
Open
Close
Norm
ally Closed
User can change to
Norm
ally Open
240Volts AC
Supply
Norm
ally Closed
User can change
Neutral
Motor Capacitor
Open Limit
Close Limit
Common
Push Button
Open Only
Close Only
Stop
Common
PED Access
Photo Beam
Common
Active
Neutral
Open
Close
M
Motor Capacitor
Output C
Output NO
DC Output +
DC Output -
Manual
Auto
Comm
on
Key Switch
Input
Earth
Receiver
AntennaAntennaShield
148mm
120mm
Block Diagram 240S2
7www.elsema.com
240VAC Supply Supplyconnectiontopowerthe240S2andthemotor
Open MotorOPENdirectionterminalClose MotorCLOSEdirectionterminalNeutral MotorneutralterminalMotor Capacitor MotorcapacitorterminalAuxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpenLimit Switch Open &Common
Iflimitswitchesareusedconnectthemtothisterminal.FactoryDefaultNormallyClosed
Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal.Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.
Open OnlyUsedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoorcannotbeclosed.Holdingthisinputwillpreventclosing.NormallyOpeninput.
Close OnlyUsedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoorcannotbeopened.Holdingthisinputwillpreventopening.NormallyOpeninput.
CommonCommonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stopandpedestrianaccess.
StopUsedtoconnectanexternalpushbuttontostopthegateordoor.HoldingthisinputwillpreventthegateordoorfromopeningorClosing.NormallyOpeninput.
Pedestrian AccessUsedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.NormallyOpeninput.
Photo Electric BeamUsedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.UsercanchangetoNormallyOpen.
DC Output 24VDC/150mA.Usetosupplyaccessories.(UseElsemaReg12toconvertthisoutputto12VDC)
Common CommonterminalforKeySwitch(NCType)Auto Autoterminalforkeyswitch.Motorwillbecontrolledbyremotecontrol
Manual Manualterminalforkeyswitch.MotorwillbecontrolledbyOpen,CloseandStoppushbuttons.
Tact Switches
TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.A=PushButtonB=OpenOnlyC=CloseOnlyD=StopE=PedestrianAccess
Slide Switch Usedtoaccessthecontrolcardfeatures.Auto Close trimpot UsedtoadjusttheAutoClosetime.Dip Switch Usedtoaccessthecontrolcardfeatures.Open, Close LEDs IndicatesOpeningorClosingcycle.Enter button Usedtochangefeaturesinprogrammingmode.
ReceiverUsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.UseElsema’sPentacodeseries.
Antenna Usedtoconnectanexternalantennaforthepluginreceiver.
Buzzer Indicatesthatchangeoffeatureswassuccessful.
FuseSlowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW(1.3HP).
8 Controller Card for 240VAC Motors
A B C D
87
E
Close
8
Pus
h B
utto
n
Ope
n O
nly
Clo
se O
nly
Sto
p
Ped
Acc
ess
Pho
to B
eam
Normally Open(NO)
Normally ClosedUser can change
Com
mon
Com
mon
+ -24V DC out150mA max
Status LED's
Test buttons
Ope
nC
lose
Slow Speed orForce adjustment
240S1
Electrical WiringAlwaysswitchoffpowerbeforedoinganywiring.Makesurethatallthewiringiscompletedandthatthemotorisconnectedtothecontrolcard.Recommended wire strip length should be 10mm for all connections to
the plug in terminal blocks.
Inputs and Outputs DiagramThediagrambelowshowstheinputsandoutputsavailable,theirfactorydefaultsettings,statusLED’sandthetestbuttonforeachinput.
Setup Instructions
DANGERMains
voltage
9www.elsema.com
7 8
A B C D E
8
Pus
h B
utto
n
Ope
n O
nly
Clo
se O
nly
Sto
p
Ped
Acc
ess
Pho
to B
eam
Normally Open(NO)
Normally ClosedUser can change
Com
mon
Com
mon
+ -
24V DC out150mA max
Status LED's Test buttons
Common
Auto
Manual
3 position Key Switch NC (Normally Closed)
240S2
Open, Close and Remote Control InputsTheopenandcloseinputsarefactorydefaultsettingtooperateaspressandhold.Thismeanstheuserwillneedtokeeppressingtheinputforthegate/doortooperate.Theremotecontrolinputsarefactorydefaultsettingtooperateaslatching.Thismeanstheuserpressestheremotebuttononceandthegate/doorwillfullyopenorfullyclose.Thepressandholdandlatchingfunctionscanbechangedbyfollowingthestepsandtablebelow:1. Setdipswitch7and8“ON”and1to6“OFF”2. Setthemodeswitchtoprogrammode1
PTO
10 Controller Card for 240VAC Motors
3. Setdipswitch1,2,3and4asshowninthetablebelow
Dip switch 1 Dip switch 2 Dip switch 3 Dip switch 4
OpenButtonOn=PressandHold
Off=Latching
CloseButtonOn=PressandHold
Off=Latching
RemoteButton1On=PressandHold(Button1OpenOnly)
Off=Latching
RemoteButton2On=PressandHold(Button2CloseOnly)
Off=Latching
4. PresstheEnterbutton.5. Buzzerwillbeeptoconfirmthechangewassuccessful6. SetalldipswitchesoffandthemodeswitchtoRun.IftheremotecontrolistobeusedforOpenOnlyandCloseOnlyfunctionthenthedipswitch2shouldbesetoninnormalrunmode.
Orangetextindicatesfactorydefaultsetting
Stop and Reverse feature for Push Button and Remote Control on Close CycleThisfeatureisusedtodisableorenablethestopandreversefeatureforthepushbuttonandremotecontrolontheclosingcycle.Factorydefaultisenabled,thereforeonclosingapushbuttonactivationwillstopthegate/doorandautomaticallyopenit.Followthestepsbelowtodisableorenablethisfeature.1. Setdipswitch5and8to“ON”2. Setdipswitch1to4and6,7to“OFF”3. Setthemodeswitchtoprogrammode1.Run
LEDwillturnred4. Pressbutton“A”todisableStopandReverse
featureorpressbutton“C”toenableStopandReversefeature.
5. Buzzerwillbeeptoconfirmthechangewassuccessful
6. Setalldipswitchesto“OFF”andmodeswitchtorun
Push Button Open OnlyThisfeaturechangesthefunctionofthepushbuttonto“OpenOnly”.Thepushbuttoninputwillopengate/door,pushbuttoncannotclosegate/door.Pushbuttoninputwillbethesamefunctionasopenonlyinput.Followthestepsbelowtoenableordisablethisfeature.1. Setdipswitch5and6to“ON”2. Setdipswitch1to4and7,8“OFF”3. Setthemodeswitchtoprogrammode1.Run
LEDwillturnred4. Pressbutton“A”toenablePBopenonlyor
pressbutton“C”todisablePBopenonly.5. Buzzerwillbeeptoconfirmthechangewas
successful6. Setalldipswitchesto“OFF”andmode
switchtorun
11www.elsema.com
Relay
1 2 3 4 5 6
Ope
n L
imit
Clo
se L
imit
Normally ClosedUser can change toNormally Open
Limit switch status LED's
Photoelectric Beam PolarityTochangethephotoelectricbeampolarityfollowthesesteps:1. Setdipswitch6and8“ON”2. Setdipswitch1to5and7“OFF”3. Setmodeswitchtoprogrammode1,therunLEDwillturnred4. Pressbutton“A”fornormallyopenorbutton“C”fornormallyclosed5. Buzzerwillbeeptoconfirmthechangewassuccessful6. SetmodeswitchtoRun
Limit Switch– Internal Limit SwitchesInternalmotorlimitswitchesareusuallyconnectedinserieswiththemotorwiresandtheydonotrequireanyconnectiontothecontrolcard.Usetraveltimertosetupmotortraveldistances.
– External Limit Switches Connected to the Control CardIfyouareusingexternallimitswitchesmakesuretheyareconnectedtothecontrolcardasshowninthediagrambelow.CheckthelimitswitchstatusLED’sareindicatingthecorrectstatusofthelimitswitches.LED“ON”meanslimitswitchisactivated.
Tochangethelimitswitchpolarityfromnormallyclosedtonormallyopen,followthesesteps:1. Setdipswitch8“ON”2. Setdipswitch1to7“OFF”3. Setmodeswitchtoprogrammode1,therun
LEDwillturnred4. Pressbutton“A”fornormallyopenlimitsor
button“C”fornormallyclosedlimits5. Buzzerwillbeeptoconfirmthechangewas
successful6. SetmodeswitchtoRun
12 Controller Card for 240VAC Motors
Supply and Motor Wiring DiagramConnectthesupplyand240VACmotorasshowninthediagrambelow.Ifthemotordoesnothaveaninternalstartingcapacitortheboardhasprovisiontoconnectthecapacitor.
WarningMakesurethatthemainspowerisalwaysswitchedoffbeforedoinganywiring.
FUSE
6
M
Active
Neutral
240Volts AC Supply
Motor Neutral
Open Close
Motor Capacitor
Earth
240S1E/240S2E
DANGERMains
voltage
13www.elsema.com
Setup Travel Timer, Slow Speed and ForceUsetraveltimersetupifoneofthefollowingapplies:• Slowspeedisrequired.• Forceneedstobeadjusted.• Usinginternalmotorserieslimitswitches.• Usinglinearmotorsormotorswithamechanicalclutch.• Usingexternallimitswitchesandneedmorethan90secondtraveltime.ThetraveltimercanbeprogrammedusingthePushButtoninput,RemoteControlinput,OpenOnlyButtoninputandCloseOnlyButtoninput.
Force Adjustment Forceadjustmentshouldbedonebeforesettingtraveltime.Traveltimesetupwillhavetobedoneagainifforceadjustmentischanged.1. Closethedoor/gatefullyandpowerupthecontrolboard2. Setdipswitch2and7“ON”3. Setdipswitch1,3to6and8“OFF”4. SetmodeswitchtoProgrammode1,therunLEDwillturnred5. PresstheEnterbutton,thebuzzerwillgiveashortbeep6. PressbuttonBorOpeninputtoopenthedoor/gate.AdjusttheOpenForceTrimpottoadjustthe
openingforceofthemotor7. PressbuttonCorCloseinputtoclosethedoor/gate.AdjusttheCloseForceTrimpottoadjustthe
closingforceofthemotor8. Repeatsteps6and7untiltherequiredforceisachievedinbothdirections.9. Fullyclosethegateandproceedtotraveltimesetup
Travel Time Setup1. Setdipswitch7“ON”only.(Swichdipswitch2“OFF”ifforcewasadjusted)2. Setdipswitch1to6and8“OFF”3. SetmodeswitchtoProgrammode1,therunLEDwillturnred4. PresstheEnterbutton,theopenLEDwillstartflashing5. Pressandholdthepushbuttoninputortheremotecontrol,doorwillstartopening6. Releasethepushbuttonorremotewhenthedoor/gatereachesthefullyopenposition7. PresstheEnterbutton,thecloseLEDwillstartflashing8. Pressandholdthepushbuttoninputortheremotecontrol,door/gatewillstartclosing9. Releasethepushbuttonorremotewhenthedoor/gatereachesthefullycloseposition10.PresstheEnterbutton,thebuzzerwillbeepfor2sectoindicatelearningissuccessful11.SetmodeswitchtoRunModeorchangedipswitchtoexitlearnmode
14 Controller Card for 240VAC Motors
Slow SpeedInordertouseslowspeed,traveltimehastobesetup.Theslowspeedcanbeadjustedanytimeduringsetuporinnormalrunmode.Slowspeedcanbeadjustedindependentlyforopenandclose.Ifslowspeedisnotrequired,turnthebluepotsfullyclockwise.
Setup Pedestrian Access Travel TimerPedestrianaccessopensthegate/doorforashorttimetoallowsomeonetowalkthroughthegate/doorbutdoesnotallowavehicleaccess.Thefactorydefaultpedestrianaccesstraveltimeris3seconds.Tochangethedefaulttime,followthestepsbelow.1. Closethedoor/gatefullyandpowerupthecontrolboard2. Setdipswitch6“ON”3. Setdipswitch1to5and7,8“OFF”4. Setmodeswitchtoprogrammode1,therunLEDwillturnred5. PresstheEnterbutton,theopenLEDwillstartflashing6. Pressandholdthepushbuttoninputortheremotecontrol,door/gatewillstartopening7. Releasethepushbuttonorremotewhenthedoor/gatereachesthepedestrianaccessopenposition8. PresstheEnterbutton,thecloseLEDwillstartflashing9. Pressandholdthepushbuttonortheremotecontrol,door/gatewillstartclosing10.Releasethepushbuttonorremotewhenthedoor/gatereachesthefullycloseposition11.PresstheEnterbutton,thebuzzerwillbeepfor2secondstoindicatelearningissuccessful12.SetmodeswitchtoRunModeorchangedipswitchtoexitPedestrianAccessLearnmode
Courtesy Light and Lock TimeDipswitch6allowsyoutosetuptheAUXrelayoutputtoeitheralightorlockoutput.Dipswitch6“OFF”inRunmode=>AUXRelayoutputiscourtesylightDipswitch6“ON”inRunmode=>AUXRelayoutputislock
Courtesy Light Courtesylighttimeisasfollows:• Onpoweruplightisonfor60seconds• Lightstaysonfor60secondsaftertheendofeachruncycle.
Controlling the Courtesy Light with a Remote ControlButton2oftheremotecanbesettooperatethecourtesylightbyselectingdipswitch7on.Thiswilloverridetheclosefunctionofbutton2oftheremoteifselected.
15www.elsema.com
Lock TimeWhentheauxiliaryrelayisprogrammedasalockoutputtherelayisactivatedforasettimeontheopeningandclosingcycle.Thefactorydefaultlocktimeis2seconds.
Tochangethedefaultlocktimefollowthesesteps:1. SetmodeswitchtoProgramMode12. Setdipswitch6and7“ON”3. PressButtonAfortherequireddurationofthelocktime4. ReleaseButtonA5. Buzzerwillbeeptoindicatelocktimehasbeenchanged6. Switchoffalldipswitches7. SetmodeswitchtoRunmode
BrakeWhenenabledthisfeatureappliesbraketothegate/doorwhenitstops.Idealifthegate/doorisinstalledinaslopingplane.Thefactorydefaultis“OFF”.Toenablebrakefollowthesesteps:1. SetmodeswitchtoProgramMode12. Setdipswitch5and7“ON”3. Setdipswitch1to4and6,8to“OFF”4. Pressbutton“A”toenablebrake
orpressbutton“C”todisablebrake5. Switchoffalldipswitches6. SetmodeswitchtoRunmode
Overrun TimeTheoverruntimeisextratimeaddedtothelearnttraveltime.Addingoverruntimecancompensateforwindormechanicalloading.Thefactorydefaultis10sec.Tochangeoverruntimefollowthesesteps:1. SetmodeswitchtoProgramMode12. Setdipswitch5“ON”3. Setdipswitch1to4and6,7,8to“OFF”3. Pressbutton“A”for30seconds,“C”for10secondsor“E”for2seconds4. Switchoffalldipswitches5. SetmodeswitchtoRunmode
16 Controller Card for 240VAC Motors
Dip Switch Functions
Feature Dip Switch settings Description
AutoClose
Dipswitch1“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Autocloseisafeaturethatautomaticallyclosesthegate/doorafterapresettimehascounteddowntozero.Adjusttheautoclosetrimpot
tochangetimebetween3–60seconds.
RemoteControlOpenOnlyand
CloseOnly
Dipswitch2“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Bydefaulttheremotecontrolallowstheusertoopenandclosethegate/doorwithbutton1.Thismodedisablesclosingforthe
remotecontrolonbutton1andmovestheclosingfunctiontobutton2oftheremotecontrol.
SecurityClose
Dipswitch3“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Gate/doorwillcloseassoonasthevehiclehaspassedthroughthephotoelectricbeam.
PhotoelectricBeam
Dipswitch4and5“OFF”ON DIP
1 2 3 4 5 6 7 8
Photoelectricbeamstopsandopensgate/dooronclosecycle
PhotoelectricBeam(SpecialSecurityClose)
Dipswitch4“ON”and5“OFF”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Photoelectricbeamstopsgate/dooronclosecycle
PhotoelectricBeam
Dipswitch4“OFF”and5“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Photoelectricbeamstopsgate/dooronopenandclosecycle
PhotoelectricBeam
Dipswitch4and5“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Photoelectricbeamstopsandclosesgate/dooronopencycle
AuxiliaryRelayCourtesyLightor
Lock
Dipswitch6“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Dipswitch6“OFF”-AUXRelayoutputiscourtesylightDipswitch“ON”-AUXRelayoutputislock
AuxiliaryRelay2ChannelCourtesy
Light
Dipswitch7“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Button2oftheremotewillswitch“ON”thecourtesylightfor60secs
AuxiliaryRelayStrobeLight
Dipswitch8“ON”ON DIP
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
AuxRelayoutputisstrobelightoutput.Relayisonlyactivatedwhenthegate/doorismoving.Dipswitch8“ON”overrides
courtesylightandlock.
17www.elsema.com
InAUTOmodetheOpenandClosebuttononthefrontofthecasearedisabled.
OFF:WhenthekeyisintheOFFposition,thecontroller(motor)doesnotwork.Thepushbuttonsandthewirelessremotesaredisabled.
MANUAL:WhenthekeyisintheMANUALpositionthecontroller(motor)willonlyoperatewiththepushbuttonsthatareonthefrontpanel.Wirelessremotecontrolsaredisabled.
Test Buttons and status LED’sEachinputhasabuilt-intestbuttonandastatusLED.Thetestbuttonsarelocatedbehindtheterminalblocksofeachinput.ThestatusLEDisnexttotheinputtestbuttons.
FuseThestandardfuseincludedwiththeboardisaslowblow5Amps(5x20mm).Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW(1.3HP).
Resetting to Factory DefaultThiswillresetthecontrollercardbacktoitsfactorydefaultsettings.1. Setdipswitch6,7,8“ON”2. Setdipswitch1to5“OFF”3. Setmodeswitchtoprogrammode2,therunLEDwillturnorange4. PressEnterbuttonfor5secondsthebuzzerwillbeeptoconfirmtheresettingwassuccessful5. SetmodeswitchtoRunmode.
This feature is only available on the 240S2EKAUTO:WhenthekeyisintheAUTOpositionthecontroller(motor)canbeoperatedby:
• Wirelessremotecontrolifthereceiverisinstalled• Pushbuttoninputonthecircuitboardwhichcanbeusedtoconnect
externalpushbuttons,swipecard,loopdetectorsorkeypadsPushbuttoninputisopen,stop,close.Ifdevicessuchasswipecardorloopdetectorsareusedwhichonlyopensthegate/door,thePBinputshouldbeconfiguredasOPENONLY.
• Pedestrianaccessinputonthecircuitboardwhichcanbeusedtoconnectexternalpushbuttons,swipecard,loopdetectorsorkeypads
• Stopbuttononthefrontofthecase
Key switch
18 Controller Card for 240VAC Motors
Accessories
Key FOB RemoteThelatestPentaserieskeyfobremotewithminireceiversensuresyourgatesordoorsaresecure.Visithttp://www.elsema.com/key-fob.htmformoredetails.
Photoelectric beamThephotoelectricbeamisusuallyusedasasafetydevicetocontrolautomaticgatesanddoors.Elsemahasseveraltypesofphotoelectricbeamsincludingretro-reflectiveandthroughbeamwithIP-66ratingsforoutdooruse.
PE24 (Through-beamtype)
PE1500 (Retro-reflectivetype)
PentaCODE® Series PentaFOB® Series
19www.elsema.com
MD2010 LD30-12
MD12-2 (2Channel)
MD12-1 (1Channel)
Vehicle Loop Detectors Thedigitaltechnologyoftheloopdetectorsisusedtodetectmetalobjectssuchasmotorvehicles,motorbikesortrucks.Loopdetectorshavebecomeapopulartoolhavinginnumerableapplicationsinpolicing,rightfromsurveillanceoperationstotrafficcontrol.Automationofgatesanddoorshasbecomeapopularusageoftheloopdetector.Thedigitaltechnologyoftheloopdetectorenablestheequipmenttosenseachangeintheinductanceoftheloopassoonasitdetectsthemetalobjectinitspath.
Alsoavailablewith240VACSupplyConnection
ELSEmA PTy LTD
31 Tarlington Place Smithfield NSW 2164 Australia
P 02 9609 4668 F 02 9725 2663W www.elsema.com
BLDF