+ All Categories
Home > Documents > 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card...

240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card...

Date post: 22-Sep-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
20
Controller Card for 240VAC Motors used on Light Commercial Doors, Industrial Roller Shutters, Sectional Doors, Garage Doors, Sliding Doors and Swing Gates VERSION 3 www.elsema.com 240S1 240S2
Transcript
Page 1: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

Controller Card for 240VAC Motors used on Light Commercial Doors, Industrial Roller Shutters,

Sectional Doors, Garage Doors, Sliding Doors and Swing Gates

VERSION 3

www.elsema.com

240S1240S2

Page 2: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

2 Controller Card for 240VAC Motors

Features• Adjustableautoclose• Adjustableslowspeedforopenandclose• Deadmancontrolsforopenandcloseinputs• Automaticgroundandtraveldistancecalibration• Photocell,pedestrianandwirelessremotecontrolinputs• Externalkeyswitchforsafetyandsecurity(Onlyon240S2)• SupportsNCorNOlimitswitchinputsortraveltimersetup• Auxrelayoutputtocontrolcourtesylightsandotheraccessories• 24VDCoutputtosupplyexternalaccessoriessuchasloopdetectors,swipecardsetc• Toroidaltransformerforexcellentefficiencyandlowleakagelossesreducingyourelectricity

consumption.DynamicPowerSavings• Customisedmodelsavailableuponrequest,120S1and120S2forinternationalmarkets

DescriptionThe240S1and240S2areverysimilarcardsexceptforthecardsizeandthe240S2hasakeyswitchinput.Offeringtwodifferentsizesallowsthecardstobeeasilyinstalledintoexistingcasesasreplacementorupgradecards.Thesetwocardsareoneofourbestvaluedcardsonthemarket,sellingforaverycompetitiveprice,yetstillloadedwithmanyfeatures.Thecontrolcardswerebuiltfromthegroundup,basedoncustomerfeedbackandusingtoday’stechnology.Withitsrichfunctions,consumerfriendlypriceandwiththefocusduringdevelopmentbeingeaseofuseandsetupmakesthese240VACcontrolcardstheultimateboardtocontrolyourmotors.Atoroidaltransformerisusedtopowerthecontrolcardandcontactors.Usingatoroidaltransformeroffersthefollowingadvantages:• Excellentefficiencyandlowleakagelossesreducingyourelectricityconsumption• Highisolationwhichprotectstheelectronicsfromnoisypowerlines• LowmagneticfieldradiationandnoacousticnoiseenablingthecontrollertopassEMCandother

stringentradiationtests

Allinstallationsandtestingmustbedoneonlyafterreadingandunderstandingallinstructionscarefully.Allwiringsshouldbedoneonlybytrainedtechnicalpersonnel.Failingtofollowinstructionsandthesafetywarningsmayresultinseriousinjuryand/ordamagetoproperty.ElsemaPtyLtdshallnotbeliableforanyinjury,damage,cost,expenseoranyclaimwhatsoevertoanypersonorpropertywhichmayresultfromimproperuseorinstallationofthisproduct.

Important warning and safety instructions

Page 3: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

3www.elsema.com

Part Numbers:Part Number Description Application

240S1E

The240S1EisenclosedinacompactIP66ratedplasticenclosure.CaseSize:175x175x75mm

120S1E-120VACversionforinternationalmarketswith120VACVoltage

LightCommercialDoors,IndustrialRollerShutters,SectionalDoors,GarageDoors,SlidingDoorsand

SwingGates

240S2E

The240S2EisenclosedinaIP66ratedplasticenclosurewithUP/DOWN/STOPexternalpushbuttons.

120S2E-120VACversionforinternationalmarketswith120VACVoltage

LightCommercialDoors,IndustrialRollerShutters,SectionalDoors,GarageDoors,SlidingDoorsand

SwingGates

240S2EK

The240S2EKisenclosedinaIP66ratedplasticenclosurewithUP/DOWN/STOPexternalpushbuttonsandkeyswitchforextrasecurityandsafety.

120S2EK-120VACversionforinternationalmarketswith120VACVoltage

LightCommercialDoors,IndustrialRollerShutters,SectionalDoors,GarageDoors,SlidingDoorsand

SwingGates

240S1

The240S1controlcardonlywithboardsizeof148x92mm.

120S1-120VACversionforinternationalmarketswith120VACVoltage

Replacementorupgradecontrollercardfor240VACMotors

240S2

The240S2controlcardonlywithboardsizeof148x120mmandkeyswitchinput.

120S2-120VACversionforinternationalmarketswith120VACVoltage

Replacementorupgradecontrollercardfor240VACMotors

Allthesecontrollersaresuitableformotorsupto1.5kW(2.0Hp).

Riskinthegoodspurchasedshallunlessotherwiseagreedinwrittenpasstothebuyerupondeliveryofthegoods.Anyfiguresorestimatesgivenforperformanceofgoodsarebaseduponthecompany’sexperienceandiswhatthecompanyobtainsontests.ThecompanywillnotacceptliabilityforfailuretocomplywiththefiguresorestimatesduetothenatureofvariableconditionsaffectingforexampleRadioRemoteControls.Pleasekeepthissetupinstructionforfuturereference.

Page 4: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

4 Controller Card for 240VAC Motors

Block Diagram 240S1

Page 5: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

5www.elsema.com

240VAC Supply Supplyconnectiontopowerthe240S1andthemotor

Open MotorOPENdirectionterminal

Close MotorCLOSEdirectionterminal

Neutral Motorneutralterminal

Motor Capacitor Motorcapacitorterminal

Auxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpen

Limit Switch Open &Common

Iflimitswitchesareusedconnectthemtothisterminal.FactoryDefaultNormallyClosed

Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal

Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.

Open OnlyUsedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoorcannotbeclosed.Holdingthisinputwillpreventclosing.NormallyOpeninput.

Close OnlyUsedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoorcannotbeopened.Holdingthisinputwillpreventopening.NormallyOpeninput.

CommonCommonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stopandpedestrianaccess.

StopUsedtoconnectanexternalpushbuttontostopthegateordoor.Holdingthisinputwillpreventthegateordoorfromopeningorclosing.NormallyOpeninput.

Pedestrian AccessUsedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.NormallyOpeninput.

Photo Electric BeamUsedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.UsercanchangetoNormallyOpen.

DC Output24VDC/150mA.Usetosupplyaccessories.(UseElsemaReg12toconvertthisoutputto12VDC)

Slide Switch Usedtoaccessthecontrolcardfeatures.Input Status LEDs Indicatesinputsstatus.

Tact Switches

TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.A=PushButtonB=OpenOnlyC=CloseOnlyD=StopE=PedestrianAccess

Auto Close trimpot UsedtoadjusttheAutoClosetime.Dip Switch Usedtoaccessthecontrolcardfeatures.Open, Close LEDs IndicatesOpeningorClosingcycle.Enter button Usedtochangefeaturesinprogrammingmode.

ReceiverUsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.UseElsema’sPentacodeseries.

Antenna Usedtoconnectanexternalantennaforthepluginreceiver.Buzzer Indicatesthatchangeoffeatureswassuccessful.

FuseSlowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW(1.3HP).

Page 6: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

6 Controller Card for 240VAC Motors

Relay

AB

CD

18

ON

27

65

43

RU

N

Prog1

Prog2

E

FUSE

Open

Close

Norm

ally Closed

User can change to

Norm

ally Open

240Volts AC

Supply

Norm

ally Closed

User can change

Neutral

Motor Capacitor

Open Limit

Close Limit

Common

Push Button

Open Only

Close Only

Stop

Common

PED Access

Photo Beam

Common

Active

Neutral

Open

Close

M

Motor Capacitor

Output C

Output NO

DC Output +

DC Output -

Manual

Auto

Comm

on

Key Switch

Input

Earth

Receiver

AntennaAntennaShield

148mm

120mm

Block Diagram 240S2

Page 7: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

7www.elsema.com

240VAC Supply Supplyconnectiontopowerthe240S2andthemotor

Open MotorOPENdirectionterminalClose MotorCLOSEdirectionterminalNeutral MotorneutralterminalMotor Capacitor MotorcapacitorterminalAuxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpenLimit Switch Open &Common

Iflimitswitchesareusedconnectthemtothisterminal.FactoryDefaultNormallyClosed

Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal.Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.

Open OnlyUsedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoorcannotbeclosed.Holdingthisinputwillpreventclosing.NormallyOpeninput.

Close OnlyUsedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoorcannotbeopened.Holdingthisinputwillpreventopening.NormallyOpeninput.

CommonCommonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stopandpedestrianaccess.

StopUsedtoconnectanexternalpushbuttontostopthegateordoor.HoldingthisinputwillpreventthegateordoorfromopeningorClosing.NormallyOpeninput.

Pedestrian AccessUsedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.NormallyOpeninput.

Photo Electric BeamUsedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.UsercanchangetoNormallyOpen.

DC Output 24VDC/150mA.Usetosupplyaccessories.(UseElsemaReg12toconvertthisoutputto12VDC)

Common CommonterminalforKeySwitch(NCType)Auto Autoterminalforkeyswitch.Motorwillbecontrolledbyremotecontrol

Manual Manualterminalforkeyswitch.MotorwillbecontrolledbyOpen,CloseandStoppushbuttons.

Tact Switches

TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.A=PushButtonB=OpenOnlyC=CloseOnlyD=StopE=PedestrianAccess

Slide Switch Usedtoaccessthecontrolcardfeatures.Auto Close trimpot UsedtoadjusttheAutoClosetime.Dip Switch Usedtoaccessthecontrolcardfeatures.Open, Close LEDs IndicatesOpeningorClosingcycle.Enter button Usedtochangefeaturesinprogrammingmode.

ReceiverUsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.UseElsema’sPentacodeseries.

Antenna Usedtoconnectanexternalantennaforthepluginreceiver.

Buzzer Indicatesthatchangeoffeatureswassuccessful.

FuseSlowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW(1.3HP).

Page 8: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

8 Controller Card for 240VAC Motors

A B C D

87

E

Close

8

Pus

h B

utto

n

Ope

n O

nly

Clo

se O

nly

Sto

p

Ped

Acc

ess

Pho

to B

eam

Normally Open(NO)

Normally ClosedUser can change

Com

mon

Com

mon

+ -24V DC out150mA max

Status LED's

Test buttons

Ope

nC

lose

Slow Speed orForce adjustment

240S1

Electrical WiringAlwaysswitchoffpowerbeforedoinganywiring.Makesurethatallthewiringiscompletedandthatthemotorisconnectedtothecontrolcard.Recommended wire strip length should be 10mm for all connections to

the plug in terminal blocks.

Inputs and Outputs DiagramThediagrambelowshowstheinputsandoutputsavailable,theirfactorydefaultsettings,statusLED’sandthetestbuttonforeachinput.

Setup Instructions

DANGERMains

voltage

Page 9: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

9www.elsema.com

7 8

A B C D E

8

Pus

h B

utto

n

Ope

n O

nly

Clo

se O

nly

Sto

p

Ped

Acc

ess

Pho

to B

eam

Normally Open(NO)

Normally ClosedUser can change

Com

mon

Com

mon

+ -

24V DC out150mA max

Status LED's Test buttons

Common

Auto

Manual

3 position Key Switch NC (Normally Closed)

240S2

Open, Close and Remote Control InputsTheopenandcloseinputsarefactorydefaultsettingtooperateaspressandhold.Thismeanstheuserwillneedtokeeppressingtheinputforthegate/doortooperate.Theremotecontrolinputsarefactorydefaultsettingtooperateaslatching.Thismeanstheuserpressestheremotebuttononceandthegate/doorwillfullyopenorfullyclose.Thepressandholdandlatchingfunctionscanbechangedbyfollowingthestepsandtablebelow:1. Setdipswitch7and8“ON”and1to6“OFF”2. Setthemodeswitchtoprogrammode1

PTO

Page 10: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

10 Controller Card for 240VAC Motors

3. Setdipswitch1,2,3and4asshowninthetablebelow

Dip switch 1 Dip switch 2 Dip switch 3 Dip switch 4

OpenButtonOn=PressandHold

Off=Latching

CloseButtonOn=PressandHold

Off=Latching

RemoteButton1On=PressandHold(Button1OpenOnly)

Off=Latching

RemoteButton2On=PressandHold(Button2CloseOnly)

Off=Latching

4. PresstheEnterbutton.5. Buzzerwillbeeptoconfirmthechangewassuccessful6. SetalldipswitchesoffandthemodeswitchtoRun.IftheremotecontrolistobeusedforOpenOnlyandCloseOnlyfunctionthenthedipswitch2shouldbesetoninnormalrunmode.

Orangetextindicatesfactorydefaultsetting

Stop and Reverse feature for Push Button and Remote Control on Close CycleThisfeatureisusedtodisableorenablethestopandreversefeatureforthepushbuttonandremotecontrolontheclosingcycle.Factorydefaultisenabled,thereforeonclosingapushbuttonactivationwillstopthegate/doorandautomaticallyopenit.Followthestepsbelowtodisableorenablethisfeature.1. Setdipswitch5and8to“ON”2. Setdipswitch1to4and6,7to“OFF”3. Setthemodeswitchtoprogrammode1.Run

LEDwillturnred4. Pressbutton“A”todisableStopandReverse

featureorpressbutton“C”toenableStopandReversefeature.

5. Buzzerwillbeeptoconfirmthechangewassuccessful

6. Setalldipswitchesto“OFF”andmodeswitchtorun

Push Button Open OnlyThisfeaturechangesthefunctionofthepushbuttonto“OpenOnly”.Thepushbuttoninputwillopengate/door,pushbuttoncannotclosegate/door.Pushbuttoninputwillbethesamefunctionasopenonlyinput.Followthestepsbelowtoenableordisablethisfeature.1. Setdipswitch5and6to“ON”2. Setdipswitch1to4and7,8“OFF”3. Setthemodeswitchtoprogrammode1.Run

LEDwillturnred4. Pressbutton“A”toenablePBopenonlyor

pressbutton“C”todisablePBopenonly.5. Buzzerwillbeeptoconfirmthechangewas

successful6. Setalldipswitchesto“OFF”andmode

switchtorun

Page 11: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

11www.elsema.com

Relay

1 2 3 4 5 6

Ope

n L

imit

Clo

se L

imit

Normally ClosedUser can change toNormally Open

Limit switch status LED's

Photoelectric Beam PolarityTochangethephotoelectricbeampolarityfollowthesesteps:1. Setdipswitch6and8“ON”2. Setdipswitch1to5and7“OFF”3. Setmodeswitchtoprogrammode1,therunLEDwillturnred4. Pressbutton“A”fornormallyopenorbutton“C”fornormallyclosed5. Buzzerwillbeeptoconfirmthechangewassuccessful6. SetmodeswitchtoRun

Limit Switch– Internal Limit SwitchesInternalmotorlimitswitchesareusuallyconnectedinserieswiththemotorwiresandtheydonotrequireanyconnectiontothecontrolcard.Usetraveltimertosetupmotortraveldistances.

– External Limit Switches Connected to the Control CardIfyouareusingexternallimitswitchesmakesuretheyareconnectedtothecontrolcardasshowninthediagrambelow.CheckthelimitswitchstatusLED’sareindicatingthecorrectstatusofthelimitswitches.LED“ON”meanslimitswitchisactivated.

Tochangethelimitswitchpolarityfromnormallyclosedtonormallyopen,followthesesteps:1. Setdipswitch8“ON”2. Setdipswitch1to7“OFF”3. Setmodeswitchtoprogrammode1,therun

LEDwillturnred4. Pressbutton“A”fornormallyopenlimitsor

button“C”fornormallyclosedlimits5. Buzzerwillbeeptoconfirmthechangewas

successful6. SetmodeswitchtoRun

Page 12: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

12 Controller Card for 240VAC Motors

Supply and Motor Wiring DiagramConnectthesupplyand240VACmotorasshowninthediagrambelow.Ifthemotordoesnothaveaninternalstartingcapacitortheboardhasprovisiontoconnectthecapacitor.

WarningMakesurethatthemainspowerisalwaysswitchedoffbeforedoinganywiring.

FUSE

6

M

Active

Neutral

240Volts AC Supply

Motor Neutral

Open Close

Motor Capacitor

Earth

240S1E/240S2E

DANGERMains

voltage

Page 13: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

13www.elsema.com

Setup Travel Timer, Slow Speed and ForceUsetraveltimersetupifoneofthefollowingapplies:• Slowspeedisrequired.• Forceneedstobeadjusted.• Usinginternalmotorserieslimitswitches.• Usinglinearmotorsormotorswithamechanicalclutch.• Usingexternallimitswitchesandneedmorethan90secondtraveltime.ThetraveltimercanbeprogrammedusingthePushButtoninput,RemoteControlinput,OpenOnlyButtoninputandCloseOnlyButtoninput.

Force Adjustment Forceadjustmentshouldbedonebeforesettingtraveltime.Traveltimesetupwillhavetobedoneagainifforceadjustmentischanged.1. Closethedoor/gatefullyandpowerupthecontrolboard2. Setdipswitch2and7“ON”3. Setdipswitch1,3to6and8“OFF”4. SetmodeswitchtoProgrammode1,therunLEDwillturnred5. PresstheEnterbutton,thebuzzerwillgiveashortbeep6. PressbuttonBorOpeninputtoopenthedoor/gate.AdjusttheOpenForceTrimpottoadjustthe

openingforceofthemotor7. PressbuttonCorCloseinputtoclosethedoor/gate.AdjusttheCloseForceTrimpottoadjustthe

closingforceofthemotor8. Repeatsteps6and7untiltherequiredforceisachievedinbothdirections.9. Fullyclosethegateandproceedtotraveltimesetup

Travel Time Setup1. Setdipswitch7“ON”only.(Swichdipswitch2“OFF”ifforcewasadjusted)2. Setdipswitch1to6and8“OFF”3. SetmodeswitchtoProgrammode1,therunLEDwillturnred4. PresstheEnterbutton,theopenLEDwillstartflashing5. Pressandholdthepushbuttoninputortheremotecontrol,doorwillstartopening6. Releasethepushbuttonorremotewhenthedoor/gatereachesthefullyopenposition7. PresstheEnterbutton,thecloseLEDwillstartflashing8. Pressandholdthepushbuttoninputortheremotecontrol,door/gatewillstartclosing9. Releasethepushbuttonorremotewhenthedoor/gatereachesthefullycloseposition10.PresstheEnterbutton,thebuzzerwillbeepfor2sectoindicatelearningissuccessful11.SetmodeswitchtoRunModeorchangedipswitchtoexitlearnmode

Page 14: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

14 Controller Card for 240VAC Motors

Slow SpeedInordertouseslowspeed,traveltimehastobesetup.Theslowspeedcanbeadjustedanytimeduringsetuporinnormalrunmode.Slowspeedcanbeadjustedindependentlyforopenandclose.Ifslowspeedisnotrequired,turnthebluepotsfullyclockwise.

Setup Pedestrian Access Travel TimerPedestrianaccessopensthegate/doorforashorttimetoallowsomeonetowalkthroughthegate/doorbutdoesnotallowavehicleaccess.Thefactorydefaultpedestrianaccesstraveltimeris3seconds.Tochangethedefaulttime,followthestepsbelow.1. Closethedoor/gatefullyandpowerupthecontrolboard2. Setdipswitch6“ON”3. Setdipswitch1to5and7,8“OFF”4. Setmodeswitchtoprogrammode1,therunLEDwillturnred5. PresstheEnterbutton,theopenLEDwillstartflashing6. Pressandholdthepushbuttoninputortheremotecontrol,door/gatewillstartopening7. Releasethepushbuttonorremotewhenthedoor/gatereachesthepedestrianaccessopenposition8. PresstheEnterbutton,thecloseLEDwillstartflashing9. Pressandholdthepushbuttonortheremotecontrol,door/gatewillstartclosing10.Releasethepushbuttonorremotewhenthedoor/gatereachesthefullycloseposition11.PresstheEnterbutton,thebuzzerwillbeepfor2secondstoindicatelearningissuccessful12.SetmodeswitchtoRunModeorchangedipswitchtoexitPedestrianAccessLearnmode

Courtesy Light and Lock TimeDipswitch6allowsyoutosetuptheAUXrelayoutputtoeitheralightorlockoutput.Dipswitch6“OFF”inRunmode=>AUXRelayoutputiscourtesylightDipswitch6“ON”inRunmode=>AUXRelayoutputislock

Courtesy Light Courtesylighttimeisasfollows:• Onpoweruplightisonfor60seconds• Lightstaysonfor60secondsaftertheendofeachruncycle.

Controlling the Courtesy Light with a Remote ControlButton2oftheremotecanbesettooperatethecourtesylightbyselectingdipswitch7on.Thiswilloverridetheclosefunctionofbutton2oftheremoteifselected.

Page 15: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

15www.elsema.com

Lock TimeWhentheauxiliaryrelayisprogrammedasalockoutputtherelayisactivatedforasettimeontheopeningandclosingcycle.Thefactorydefaultlocktimeis2seconds.

Tochangethedefaultlocktimefollowthesesteps:1. SetmodeswitchtoProgramMode12. Setdipswitch6and7“ON”3. PressButtonAfortherequireddurationofthelocktime4. ReleaseButtonA5. Buzzerwillbeeptoindicatelocktimehasbeenchanged6. Switchoffalldipswitches7. SetmodeswitchtoRunmode

BrakeWhenenabledthisfeatureappliesbraketothegate/doorwhenitstops.Idealifthegate/doorisinstalledinaslopingplane.Thefactorydefaultis“OFF”.Toenablebrakefollowthesesteps:1. SetmodeswitchtoProgramMode12. Setdipswitch5and7“ON”3. Setdipswitch1to4and6,8to“OFF”4. Pressbutton“A”toenablebrake

orpressbutton“C”todisablebrake5. Switchoffalldipswitches6. SetmodeswitchtoRunmode

Overrun TimeTheoverruntimeisextratimeaddedtothelearnttraveltime.Addingoverruntimecancompensateforwindormechanicalloading.Thefactorydefaultis10sec.Tochangeoverruntimefollowthesesteps:1. SetmodeswitchtoProgramMode12. Setdipswitch5“ON”3. Setdipswitch1to4and6,7,8to“OFF”3. Pressbutton“A”for30seconds,“C”for10secondsor“E”for2seconds4. Switchoffalldipswitches5. SetmodeswitchtoRunmode

Page 16: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

16 Controller Card for 240VAC Motors

Dip Switch Functions

Feature Dip Switch settings Description

AutoClose

Dipswitch1“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Autocloseisafeaturethatautomaticallyclosesthegate/doorafterapresettimehascounteddowntozero.Adjusttheautoclosetrimpot

tochangetimebetween3–60seconds.

RemoteControlOpenOnlyand

CloseOnly

Dipswitch2“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Bydefaulttheremotecontrolallowstheusertoopenandclosethegate/doorwithbutton1.Thismodedisablesclosingforthe

remotecontrolonbutton1andmovestheclosingfunctiontobutton2oftheremotecontrol.

SecurityClose

Dipswitch3“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Gate/doorwillcloseassoonasthevehiclehaspassedthroughthephotoelectricbeam.

PhotoelectricBeam

Dipswitch4and5“OFF”ON DIP

1 2 3 4 5 6 7 8

Photoelectricbeamstopsandopensgate/dooronclosecycle

PhotoelectricBeam(SpecialSecurityClose)

Dipswitch4“ON”and5“OFF”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Photoelectricbeamstopsgate/dooronclosecycle

PhotoelectricBeam

Dipswitch4“OFF”and5“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Photoelectricbeamstopsgate/dooronopenandclosecycle

PhotoelectricBeam

Dipswitch4and5“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Photoelectricbeamstopsandclosesgate/dooronopencycle

AuxiliaryRelayCourtesyLightor

Lock

Dipswitch6“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Dipswitch6“OFF”-AUXRelayoutputiscourtesylightDipswitch“ON”-AUXRelayoutputislock

AuxiliaryRelay2ChannelCourtesy

Light

Dipswitch7“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Button2oftheremotewillswitch“ON”thecourtesylightfor60secs

AuxiliaryRelayStrobeLight

Dipswitch8“ON”ON DIP

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

AuxRelayoutputisstrobelightoutput.Relayisonlyactivatedwhenthegate/doorismoving.Dipswitch8“ON”overrides

courtesylightandlock.

Page 17: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

17www.elsema.com

InAUTOmodetheOpenandClosebuttononthefrontofthecasearedisabled.

OFF:WhenthekeyisintheOFFposition,thecontroller(motor)doesnotwork.Thepushbuttonsandthewirelessremotesaredisabled.

MANUAL:WhenthekeyisintheMANUALpositionthecontroller(motor)willonlyoperatewiththepushbuttonsthatareonthefrontpanel.Wirelessremotecontrolsaredisabled.

Test Buttons and status LED’sEachinputhasabuilt-intestbuttonandastatusLED.Thetestbuttonsarelocatedbehindtheterminalblocksofeachinput.ThestatusLEDisnexttotheinputtestbuttons.

FuseThestandardfuseincludedwiththeboardisaslowblow5Amps(5x20mm).Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW(1.3HP).

Resetting to Factory DefaultThiswillresetthecontrollercardbacktoitsfactorydefaultsettings.1. Setdipswitch6,7,8“ON”2. Setdipswitch1to5“OFF”3. Setmodeswitchtoprogrammode2,therunLEDwillturnorange4. PressEnterbuttonfor5secondsthebuzzerwillbeeptoconfirmtheresettingwassuccessful5. SetmodeswitchtoRunmode.

This feature is only available on the 240S2EKAUTO:WhenthekeyisintheAUTOpositionthecontroller(motor)canbeoperatedby:

• Wirelessremotecontrolifthereceiverisinstalled• Pushbuttoninputonthecircuitboardwhichcanbeusedtoconnect

externalpushbuttons,swipecard,loopdetectorsorkeypadsPushbuttoninputisopen,stop,close.Ifdevicessuchasswipecardorloopdetectorsareusedwhichonlyopensthegate/door,thePBinputshouldbeconfiguredasOPENONLY.

• Pedestrianaccessinputonthecircuitboardwhichcanbeusedtoconnectexternalpushbuttons,swipecard,loopdetectorsorkeypads

• Stopbuttononthefrontofthecase

Key switch

Page 18: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

18 Controller Card for 240VAC Motors

Accessories

Key FOB RemoteThelatestPentaserieskeyfobremotewithminireceiversensuresyourgatesordoorsaresecure.Visithttp://www.elsema.com/key-fob.htmformoredetails.

Photoelectric beamThephotoelectricbeamisusuallyusedasasafetydevicetocontrolautomaticgatesanddoors.Elsemahasseveraltypesofphotoelectricbeamsincludingretro-reflectiveandthroughbeamwithIP-66ratingsforoutdooruse.

PE24 (Through-beamtype)

PE1500 (Retro-reflectivetype)

PentaCODE® Series PentaFOB® Series

Page 19: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

19www.elsema.com

MD2010 LD30-12

MD12-2 (2Channel)

MD12-1 (1Channel)

Vehicle Loop Detectors Thedigitaltechnologyoftheloopdetectorsisusedtodetectmetalobjectssuchasmotorvehicles,motorbikesortrucks.Loopdetectorshavebecomeapopulartoolhavinginnumerableapplicationsinpolicing,rightfromsurveillanceoperationstotrafficcontrol.Automationofgatesanddoorshasbecomeapopularusageoftheloopdetector.Thedigitaltechnologyoftheloopdetectorenablestheequipmenttosenseachangeintheinductanceoftheloopassoonasitdetectsthemetalobjectinitspath.

Alsoavailablewith240VACSupplyConnection

Page 20: 240S1 240S2 Controller Card for 240VAC Motors - ElsemaSlide Switch Used to access the control card features. Auto Close trimpot Used to adjust the Auto Close time. Dip Switch Used

ELSEmA PTy LTD

31 Tarlington Place Smithfield NSW 2164 Australia

P 02 9609 4668 F 02 9725 2663W www.elsema.com

BLDF

066


Recommended