4
Product # _____________________ Type _____________ Date_______ Project Name _______________________________________________ Project Location _________________________ Prepared By ________ MODEL FL05 - Flood Light TOTAL LED POWER 240 = 240W CCT COLOR TEMP 50 – 5000K* *+/-350K LIGHT BEAM SPREAD 4 = NEMA 4HX4V INPUT VAC U = Universal 100V to 277V LIGHTING CONTROL ND = Non Dimming D = Dimming GLARE CONTROL **Consult factory for available options Ordering Guide 240W LED Sign Light 240W LED Sign Light Specifications The LED Sign Light has been engineered to efficiently light any billboards, warehouses, industrial facilities, exhibition centers, shopping malls, stadiums, toll stations, etc. Fixture replaces 800W Metal Halide lamps. Construction The LED Sign Light is made out of aluminum. Optics/Lens IP66 sealed light modules which are field replaceable provide uniform illumination. Available in 65x120° (polarized light 10°), 30x60°, 65x120° (polarized light 55°), 15° and 30° beam angle. Electrical High power LED source, with performance of greater than 110 lumens per watt. Standard Color Temperature 3000K-5000K, CRI of 70 or greater. Other optional color temp and CRI available on request. LED Drivers: UL/CSA recognized component to meet UL8750 & EN61347 (USR/CNR - E328335). Suitable for input power at 100-277VAC, Minimum power factor >0.90 with an operating temperature range of -22°+140°F / -30°+60°C. Dimmable. Finish White finish is standard. Other optional finishes available on request. Warranty and Certifications 5 years for LED Light Engine and Driver, 7 years for housing. 50,000 hours @ 25°C L70 LED Illumination per LM-80. cULus Wet Locations in compliance with UL 1598 and CSA C22.2 NO. 250.0 standards. IP66 rated. Suitable for indoor/outdoor wet or damp location use. UL, DLC, CE, RoHS listed and Lighting Facts. Note: Due to continued efforts to improve our products, specifications are subject to change without notice. MOUNTING PM = Pole Mount BM = Bracket Mount 26,400lumens Dimensions: 17.1 x 15.7 x 5.2 inches
Transcript
Page 1: 240W LED Sign Light - nslights.comnslights.com/images/resources/Signlight_240W_CS.pdf · The LED Sign Light has been engineered to ... Dialux Simulation Badminton court lighting ...

Product # _____________________ Type _____________ Date_______

Project Name _______________________________________________

Project Location _________________________ Prepared By ________

MODEL

FL05 - Flood Light

TOTAL LED POWER

240 = 240W

CCT COLOR TEMP

50 – 5000K* *+/-350K

LIGHT BEAM SPREAD

4 = NEMA 4HX4V

INPUT VAC

U = Universal100V to 277V

LIGHTING CONTROL

ND = Non Dimming D = Dimming

GLARECONTROL

**Consult factory for available options

Ordering Guide

240W LED Sign Light

240W LED Sign Light SpecificationsThe LED Sign Light has been engineered to efficiently light any billboards, warehouses, industrial facilities, exhibition centers, shopping malls, stadiums, toll stations, etc. Fixture replaces 800W Metal Halide lamps.

ConstructionThe LED Sign Light is made out of aluminum.

Optics/LensIP66 sealed light modules which are field replaceable provide uniform illumination. Available in 65x120° (polarized light 10°), 30x60°, 65x120° (polarized light 55°), 15° and 30° beam angle.

ElectricalHigh power LED source, with performance of greater than 110 lumens per watt. Standard Color Temperature 3000K-5000K, CRI of 70 or greater. Other optional color temp and CRI available on request. LED Drivers: UL/CSA recognized component to meet UL8750 & EN61347 (USR/CNR - E328335). Suitable for input power at 100-277VAC, Minimum power factor >0.90 with an operating temperature range of -22°+140°F / -30°+60°C. Dimmable.

FinishWhite finish is standard. Other optional finishes available on request.

Warranty and Certifications5 years for LED Light Engine and Driver, 7 years for housing. 50,000 hours @ 25°C L70 LED Illumination per LM-80. cULus Wet Locations in compliance with UL 1598 and CSA C22.2 NO. 250.0 standards. IP66 rated. Suitable for indoor/outdoor wet or damp location use. UL, DLC, CE, RoHS listed and Lighting Facts.

Note: Due to continued efforts to improve our products, specifications are subject to change without notice.

Smart Flood100_Layout 1 1/23/15 1:02 PM Page 1

MOUNTING

PM = Pole MountBM = Bracket Mount

26,400lumens

Dimensions: 17.1 x 15.7 x 5.2 inches

Page 2: 240W LED Sign Light - nslights.comnslights.com/images/resources/Signlight_240W_CS.pdf · The LED Sign Light has been engineered to ... Dialux Simulation Badminton court lighting ...

240W LED Sign Light

Photometrics

Smart Flood100_Layout 1 1/23/15 1:02 PM Page 2

F00801 F01601 F01602

F01603 F01604

30000

24000

18000

12000

6000

15000

12000

9000

6000

3000

400

800

1200

1600

2000

130

260

390

520

650

1400

2800

4200

5600

7000

Page 3: 240W LED Sign Light - nslights.comnslights.com/images/resources/Signlight_240W_CS.pdf · The LED Sign Light has been engineered to ... Dialux Simulation Badminton court lighting ...

240W LED Sign Light

Mounting Options

1. 2. 3.

Power connection

Fix the light on the arm Attach with screws.

Adjustable

Tighten screws after adjusting the light.

Loosen screws, the light can be adjusted by ±16°

1. 2. 3.

Mount fixture bytightening the screws 1.Release the locking knob,

then lock in place after angle adjustment is completed

2.free-adjustable angle

Page 4: 240W LED Sign Light - nslights.comnslights.com/images/resources/Signlight_240W_CS.pdf · The LED Sign Light has been engineered to ... Dialux Simulation Badminton court lighting ...

240W LED Sign Light

Billboard lighting

Mininizing light leakage results in no loss of light pollution, and has a specialized design for billboards intended to minimize shadowing.

Useful light

Flood lighting

Signlight may be used as a cutoff type flood light, specially designed for sports fields, minimizing light loss and light pollution.

Area to be lit.

Dark sky

Useful light

FL05-200 F01601 5000K Ra70

0 337.50 225 112.50 787.50 675 562.50 450 900 lx

FL05-200 F00801 5000K Ra70

0 175 262.50 350 437.50 612.50 87.50 525 700

lx

FL05-240 F01604 T55 5000K Ra70

Flood lightingDialux Simulation

Badminton court lighting simulation

FL05-240 F01602 T55 5000K Ra70

Tennis court lighting simulation

Billboard lighting


Recommended