WhirlWindCombined fully integrated gas/air control and safety system
GB-WND 057 D01
3.13
Technical DescriptionIntegrated gas-air system with high power density based on DUNGS zero pressure multiple actuator GB-ND 057 D01 to EN 126 for modulating or multi-stage mode:
- Pneumatic integrated system com-prising zero pressure mode and integrated signal gain
- Modulation range up to 1:10- Breaksupflowpatternandreduces
resonances- Offset correctionofgas/air ratioat
servo regulator-Limitsmaximumflowbyrestrictingat
low hysteresis, injector requires no replacementonchangetodifferentgas families
- Inlet pressure up to max. 65 mbar (6.5 kPa)
PrintedinGermany•Edition05.11•N
r.249596
- Implemented by adapting system components and optimising to spe-cificapplicationanddesignrequire-ments. Versions with valve on left or right available.
ApplicationSuitableforgasestoEN437andothergaseous inert media.
ApprovalsEU type test approval as per EU Gas Appliance Directive.
GB-WND057D01CE-0085CM0036
Approvals in other important gas-consuming countries.
2 … 6
Combinations Multifunctional gas control valve GB-WND 057 D01
Main types
GB-WND 057 D01
Specification
Zero
pre
ssur
e se
rvo
regu
lato
r
Ope
ratin
g va
lveSo
leno
id va
lve
[cla
ss]
Safe
ty va
lveSo
leno
id va
lve
[cla
ss]
Max
imum
re
stric
tor
Offsetcorrection
Dirt
trap
de
vice
Baffletosignal
amplifier
Gas
pre
ssur
e sw
itch
Blow
er a
dapt
er
Line
soc
ket
standard optional not available
Valve and pressure regulatorThe pressure control unit and servo pressure regulator compensates for pressure fluctuations in the supply network. This ensures a constant volumeflowatconstantinjectorpres-sure. The servo regulator regulates the nozzle pressure at the valve outlet, dependent on the vacuum generated, towards zero.
Solenoid valvesSolenoid valve to EN 161, Class B. DC coil, protected against voltage transients.
FilterFine-meshedstrainertoprotectfitting.
Side cover plate with nozzleCover plate mounted on the side be-tweenvalveandbaffletoguidesupplyair and act as noise insulation. The noz-zle is mounted between the valve and the cover plate and can be replaced in the event of changes in gas families.
Description of main components Swirl plateThe integratedbaffleactsasa two-stagecascadedsignalamplifierandpermits safe operation over a modula-tion range up to 1:10. The specially de-signed, patented. Swirl plate changes flowpatternstoreduceresonances.
Blower adapterRepresents the interface to the se-lectedblowerandensuredefinedflowratiosattheinletanddesignflexibilityinthevalve/blowerarrangement.
Gas pressure switch Optional equipmentMonitors gas pressure on the inlet side for gas leakage protection. The pres-sure switch can be pre-adjusted and sealedtocustomerspecifications.
GB- XXXXX XXX DXX SXX
Gas train schematic diagram1 = two class B solenoid valves with pressure regulator2 = two class B solenoid valves without pressure regulator
Design type (generation) D
Construction size, nominal diameter05 = pmax. = 65 mbar
3 = Rp 1/4 5 = Rp 1/2 7 = Rp 3/4
Opening behaviour + main volume restrictorwithout = fast-opening, fast-closing-L = slow-opening-E = adjustable start gas-P = pilotgas connection-G = Gas/Air ratio-D = main flow setting-N = Zero-Governor-M = electrical modulating type-W = Whirlwind version-Z = two stage
GasBloc
S = Series (type-independent)
Outlet pressure Inlet pressure0 = 0 mbar bis 65 mbar2 = 1,5 - 20 mbar bis 65 mbar4 = 3 - 40 mbar bis 65 mbar
Control of V1 and V20 = common2 = separated
Valve design 0 = Double valve1 = Single valve, right angle2 = Single valve, straight
Type key of Gasbloc
A FilterB Automaticshut-offvalvesC Pressure regulatorD Servo-pressure regulatorE MainflowrestrictorF NozzleG BaffleforsignalgainH Fanp1 Test nipple, inletp2 Test nipple, outlet
Air/differential pressure switch(Optional equipment)Thesystemoffers theoptionofcon-nectinganairordifferentialpressureswitch for monitoring blower function. Theairordifferentialpressureswitchcan be pre-adjusted and sealed to customerspecifications.
Pressure instrument glandsOn inlet and outlet sides
Solenoid valve modesV1 and V2 can be activated and opened either together or separately.
Block diagram
B B
V1 V2
C
Pamb
B B D
EP2P1A HGF
Supp
ly ai
r col
lect
or
MPA109x
3 … 6
Setting the CO2 characteristic GB-WND 057 D01
Legend
1 Fine-meshed strainer 2 Housing 3ValveV1 4Closingspring 5 Plunger V1 6 Test nipple 7 Solenoid V1 8 Valve V2 9Startgassetting 10 Solenoid V2
11 Working diaphragm 12 Return spring13Operatingvalve14Electricalconnection 15 Servo-pressure regulator16 Injector17 Swirl plate18 Blower adapter19Sidecoverplate
RatingQ [%]
9
5040
7
6
5
4
3
2
1
03020100 60 70 80
CO2 [%]
90 100
8
10
Emis
sion
Setting by means ofmaximum restrictor
Setting by means ofoffset adjustment
Functional diagram GB-WND 057 D01
��
��
��
��
�� ��
��
��
��
��
��
��
��
��
��
��
��
�
�
�
�
�
�
�
�
�
Adjustment instructions
Rapid and simple adjustment by means of:
•Adjustoffsetcorrectionusingsettingscrew on servo regulator.
•Adjustmaximumflowusing flow-restriction screw.
4 … 6
Dimensions [mm]
Electrical connection
StandardBoxwithcableconnectionIP40MolexCrimpSystem3001
Adjusting devices
Solenoid coils
Pressure regulatoroffsetadjustment
Pressure test nipple P2
Pressure test nipple P1
Maximum restrictor
5828
111
ø9
40,5ø5
536
36
82
4xM5-9deep
Rp3/4ISO7/1
105XX:90kW:26mm
120 kW: 28,5 mm
ø110
5 … 6
Permissible deviationPressure regulator class C
p2 ±10 % as per EN 126
������������������������������ ����������� ������������������ �
�����
���
�
�
�
�
��
�
�
��
��
��
��
��
��
���
��
� � � � �� � �� ��
�����������������������������������
��� ��� ��� ��� ��� ��� ���
� � � � �� � �� �� ����� ��� ��� ��� ��� ���
�������������������������������������� �
��������������������
Volume flow pressure difference characteristicGB-WND 057 D01 - pneumatic to DIN EN 126
Swirl Plate GB-WND 057 D01
Integrated venturi2.Signalamplifier
Spiralbaffleplates1.Signalamplifier
6 … 6
We reserve the right to make any changes in the interest of technical progress.
WhirlWindCombined fully integrated gas/air control and safety system
GB-WND 057 D01
Head Offices and Factory Karl Dungs GmbH & Co. KGSiemensstraße 6-10D-73660 Urbach, GermanyTelefon +49 (0)7181-804-0Telefax +49 (0)7181-804-166
Nominal diameterGas connectionFlange with tube threadMax. inlet pressureNominalflow
Ambient temperature
Automaticshut-offvalvesGroupPressure regulatorProportional adjustment range VMinimum signal pressureOffsetcorrectionDegree of protectionOpening timeClosing timeSwitch on durationVoltage/frequency
Loadofcoil(24V,230V)Electrical connection
Optional equipment
Installation position
Specifications DN 15Rp3/4 ISO7/1Rp1/2 ISO7/1ID65 mbar (6.5 kPa)15.4m3/h(Air)at∆p30mbar(3.0kPa),governed-15 °C to +70 °C0 °C to +70 °C at LPGClass B as per EN 1262Class CV = pGas/pAIR=0,45-10.3mbar(0.03kPa)at∆poffset = 0 Pa± 0.2 mbar (0.02 kPa)IP40Fast-opening < 1 s< 1 s100 % ED~(AC)50-60Hz24V+10%–15%~(AC)50-60Hz230V+10%–15%2 x 12.5 VAMolex System connection coil orOption: Connection box with integrated cable Electrical connections in Rast 5AirpressureswitchLGW…A3AutomaticburnercontrolMPA109xGas pressure switch GW A5Supply air collectorSolenoid at any position between ver-tical and horizontal axis.