+ All Categories
Home > Documents > 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1...

255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1...

Date post: 18-Oct-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
28
www.jotron.com TR-710 USERS MANUAL
Transcript
Page 1: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

www.jotron.com

TR-710

USERS MANUAL

Page 2: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D

DEFAULT A condition that the navigator assumes automatically if no other condition is initiated by the operator.

IECInternational Electro-technical Commission.

IMOInternational Maritime Organization

IP ratingJoint factor (to indicate the waterproofing of the equipment)

ITUInternational Telecommunication Union.

LEDLight Emitting Diode.

VHFVery High Frequency -A set of frequencies in the MHz region.

VSWR

Voltage standing wave ratio.

EC Declarations of Conformity,

available at www.jotron.com

Read this Users Manual fully to familiarise yourself with the equipments functions and facilities.

Abbreviations and definitions

Page 3: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

AMENDMENT NO.

INCORP.BY

DATE PAGE(S) VERSION REASON FORCHANGE

1 07.04.05 7,8 A EM4418

2 07.04.05 8 B EM4440

3 07.04.05 17,18,22 C EM4461

4 ES 05.02.07 all D Kontroll med med

manualer.doc

5

6

7

8

9

10

11

12

13

14

15

Amendment Record

99213_UM_TR710_D 3

Page 4: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

4 99213_UM_TR710_D

I M PORT ANT BAT T ERY INFOR M A TI ON FOR TR-71 0 M A NPACK

The battery pack is of NiMH type. To get the most out of your

battery pack and avoid technical problems, a few precautions should

be taken.

1. Always switch the TR-710 “OFF” when charging the

battery. Disconnect the charger before switching the

TR-710 “ON”.

2. Always charge the battery to full charge when charging.

Avoid charging under 0°C or over + 40°C.

3. All rechargeable batteries lose charge while stored. The rate

is dependent on the temperature. When stored at 25°C a

fully charged battery will have more than 50% capacity

after a few months, while at 45°C it might be down at 50%

after approx one month.

4. If the battery has been totally discharged or stored for a long

time, the charger may terminate before full charge is

reached. In this case do as follows:

• Switch OFF the TR-710 and connect the charger for a few

minutes.

• Disconnect the charger, switch the TR-710 “ON”, and

press PTT a few times.

• Switch the TR-710 ”OFF” and connect the charger again.

5. Never short-circuit, solder, reverse charge, crush,

disassemble or incinerate the battery.

This may result in fire, explosion and severe burn hazard.

Page 5: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 5

CONTENT:

1. INTRODUCTION....................................................... 6

General information................................................................................... 6

What comes with the three versions of TR-710........................................ 6

Precautions and warnings.......................................................................... 7

Technical specifications............................................................................. 8

2. OPERATING INSTRUCTIONS.................................... 9

General operation ...................................................................................... 11

Menus ........................................................................................................ 12

3. Appendix A TR-710 Menu Flowchart ..................... 20

Page 6: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

6 99213_UM_TR710_D

1. INTRODUCTION

General information

The Jotron TR-710 represent the latest generation of Jotron Multiuse Radio

Transceivers. The radio operates at the airband 118-137 MHz with chooseable

channel spacing, 8.33 KHz, 12.5 KHz or 25 KHz. The radiotransceiver operates in

accordance to ICAO recommendations and conforms to the requirements of

European Telecom Standard Institute, ETSI, EN 300676 standard. The transceiver

will be delivered with 10 watt, 40 watt PEP, output power. The transceiver will be

supplied as 3 main versions.

What comes with the three versions of TR-710

Mobile Radio TR-710 M

• Hand microphone

• Desk top bracket

• Antenna

• Operators manual

Man-pack Radio TR-710 MP

• Shoulder bag

• Hand microphone

• Battery pack

• Battery charger

• Antenna

• Operators manual

Marine Desktop Radio TR-710 MD

• Hand microphone

• Power supply (230/110V)

• Desk top bracket

• Antenna adapter

• Operators manual

Page 7: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 7

Precautions and warnings

Batteries

The batteries are rechargeable NiMh type with a capacity of 12V/4500mAh.

The following should be noticed:

• Do not short-circuit, solder, crush, disassemble or incinerate the battery pack.

This may result in fire, explosion and severe burn hazard.

• Avoid charging batteries below 0°C or above 40°C.

Connectors and cables

When handling connectors and cables, notice the following warnings:

• Do not force plugs in place, as this may damage the pins in the plugs.

• Do not pull the cables when removing connectors from the TR-710, take instead

a firm grip around the connector and pull.

Display and front panel

Avoid touching the display with sharp objects. Scratches can reduce the visibility.

Storage and safe handling

Operating temperature is from -20°C to +55°C. Cleaning of the equipment can be

done with a cloth soaked in a mixture of ordinary dish-detergent and water.

When the radio is used intensive the cooling rib will be very hot.

Page 8: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

8 99213_UM_TR710_D

Technical specifications

Frequency range: 118 - 137 MHz.

Channel separation: 25 kHz, 12.5 / 8.33 kHz. (Selectable)

Frequency steps: 25 kHz, 12.5 / 8.33 kHz

Preset channels: 63

Type of modulation: AM (A3E)

Monitor: In headphone and rear connector

Antenna connector: 50Ω, TNC-connector

Operating temperature: -20 to + 55°C

Storage temperature: -20 to + 70°C.

Operating voltage: 230/115 VAC ± 10% (external power supply)

11-15VDC

13.7VDC nominal

Output power is reduced at lower voltages

Power consumption: 10W, 80% modulation: < 50VA

Battery package: 12VDC, 4500mAh NiMh

Dimension: 8 cm (H) x 21 cm (W) x 22 cm (D)

Weight: 1.8 kg, (2.9 kg with battery)

Hours of operation: Dutycycle 10/90% 10W (mode M and MD) 6.5 hours.

2.5W (mode MP) 8.5 hours.

Output power: 10W. Adjustable. (40W PEP)

Sensitivity: 10 dB SINAD at 1µV pd, 30 % modulation

Page 9: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 9

2. OPERATING INSTRUCTIONS

TR-710 has an interface that is easy to use, with a self-explanatory graphical display.

Figure A: Keyboard and display, TR-710.

1 Power ON/OFF.

Turns the TR-710 on and off. Has to be pushed for more than 1 sec. to power

off, in order to prevent unwanted operation.

2 Graphical LCD (Liquid Crystal Display).

The graphical display gives the user information about the frequency, menu set-

tings, choices and status. The graphical LCD has backlighting, making it easy

to see in the dark.

3 Battery Indicator

Indicate the status of the battery, four steps. The indicator flash when the battery

is close to empty. The battery indicator is only visible in Man Pack (MP) mode.

4 Control Wheel.

For changing frequency, channels, volume, squelch and adjusting selected valu-

es up and down.

5 Function keys.

For moving through menus and adjusting selected values up and down.

6 Connector for headset or hand-held microphone with PTT button.

A headset or hand-held microphone can be connected here. The connector will

also supply a headset which need a voltage supply.

Page 10: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

10 99213_UM_TR710_D

Transceiver rear connections

Figure B: Rear view, TR-710.

1 Antenna Connector.

TNC-connector for antenna input/output.

2 Power-supply Connector.

This connector is connected to the external DC supply (+11 to +15V).

3 Multifunction Connector.

For details refer to technical handbook.

Power supply connector

Figure C: Power supply connector, female.

Table 1: functional description of the power

supply connector.

Pin pair nr. Signal Function description

1 U_BAT Supply voltage (11-15V)

2 GND Common ground.

Table 1:

Page 11: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 11

General operation

There is a menu wheel on the right side of the display. The wheel has three diffe-

rent functions:

• Volume control.

• Squelch control.

• Maneuvering in menus and changing of values.

STANDARD SCREEN

This is the standard mode for the transceiver. In this mode the menu wheel auto-

matically adjust the volume and when it is operated the display gives a graphical

volume indication. The display returns to the standard screen after a break of more

than two seconds. A push on the menu wheel gives the squelch function and the

next push, or a break of more than three sec, will return to the volume function.

By pressing the function keys the user gets access to several functions and menus.

A flowchart of the menu is shown in appendix A.

When a menu is selected, the menu wheel changes its function to menu maneuve-

ring. When submenus are entered the wheel can be used to adjust the actual value.

The maneuvering in menus, and changing of values, can also be carried out by the

arrows (function keys). The display automatically returns to the standard screen

after a break of more than 30 seconds.

If the operator wants to adjust the volume or squelch when a menu is entered, one

push gives the volume function, the next gives the squelch function and the third

push gives the value adjustment.

Pressing the function key "ENTR" enters the actual menu, new values and settings

are also stored by pressing "ENTR".

Page 12: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

12 99213_UM_TR710_D

To escape or return to a higher level, push "CANCEL" (function key).

If the microphone is fitted with an internal loudspeaker the function TX SIDE

TONE has to be set OFF to avoid feedback.

Menus

PREV – Fast selection of channels

Select between present and previous channel by pushing the function key

"PREV".

BITE – Built In Test Equipment

This function menu will measure and display the parameters shown in table 2.

Table 2 indicates the limits for acceptable values for these parameters. If the limits

are exceeded an alarm will be displayed.

Measurement Normal Min Max

Temp PA - -20 °C +95 °C

Fwd Power 1W – 2,5W – 5W – 8W –10W 10W

Ref Power Depends on the antenna and forward power 0 The level of

forward power.

U Battery Depends on the power source 10.3 V 15 V

9 Volt 9 V 8,5 V 10 V

5 V Dig 5 V 4,3 V 5,6 V

5V analog 5 V 4,3 V 5,6 V

3 Volt 3 V 2,7 V 3,3 V

Current 0,4 A in receive 0,3 A 5 A (transmitting)

Modulation - 0% 100%

IF Current 6 mA

LNA Current 24.5 mA 10 mA 30 mA

RSSI 1.1 V at 1 uV - -

Temp LCD A few degrees above the ambient temperature -20°C +55°C

Table 2:

Page 13: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 13

ChannelSelect from the preset channels.Maximum preset channels: 63

The Main-menu consist of a receiver-menu,transmitter-menu and a general-menu.

CH –Selection of channels

MENU – Main Menu

Page 14: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

14 99213_UM_TR710_D

NOISE BLANK ON/OFFWhen the function is ON radar and pulse noisewill be detected and blanked out

AUDIO AGC ON/OFFAutomatic gain control of the audio amplifier. When the function is ON the gain will be adju-sted automatically to keep the audio level of thereceived signal constant.

OPEN SQ ON/OFFEquivalent as setting the squelch level to zero. When the function is ON the Squelch will beopen. This function can also be activated bypressing the function key "OPEN", that is dis-played when the squelch menu is activated bypressing the menu wheel.

Rx menu - Receiver menu

Page 15: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 15

AGC MODE SLOW/FASTAdjust the time constant of the AGC function.

MODULATION Range 10 – 100 %Sets the modulation factor of the transmitter.

AGC ON/OFFAutomatic gain control.When the function is ON the output level will bekept constant.

Tx menu - Transmitter menu

Page 16: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

16 99213_UM_TR710_D

MUTE ON/OFFWhen the function is ON the transmitter willmute low audio signals.

INPUT MIC/LINE Select between microphone input or line input.When line input is selected, "LINE" is shown inthe standard screen picture.(Line is used for remote operation).

TX POWERAdjust the output power of the transmitter.Range: 1 to 10 watt, (40 w PEP).Steps: 10, 25, 50, 80, and 100 %.

TIME OUTThis function set the maximum time for howlong the transmitter can be keyed continuously. Range: 0.5 – 5 minutes, steps of 30 seconds.This function can also be turned off.

Page 17: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 17

LCD CONTRASTAdjust the contrast in the display.Range: 19 - 62 %.

LCD LIGHTAdjust the intensity of the display.Range: OFF, 1, 2, 3.

General - General menu

Page 18: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

>25kHz STEP OFF<

18 99213_UM_TR710_D

PANEL LIGHT ON/OFFLight inside the keyboard on/off.

FREQUENCYFrequency range: 118.000 MHz to 136.975 MHz.The frequency is changed in steps of 25 kHz,8.33 / 12.5 kHz optional.

STORE CHANNELSelect channel, the actual frequency will be sto-red on this channel by pressing ENTR.

DELETE CHANNELelect channel, the actual channel will be deletedon this channel when pressing ENTR.

25kHz STEP ON/OFFSelect 25kHz step ON or OFF and press ENTR tosave.25kHz STEP OFF

Page 19: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 19

MANPACK MODE ON/OFFSet the following parameters:Forward power = 25 % /2.5 w.Set the battery symbol in the display.Turn off the radio automatically when the batte-ry voltage is lower than 10.3 Volt.

Default CANCEL/ENTERRestore default settings. When choosing ENTR all settings except fre-quencies and channels will be set to defaultvalues.

AF OUT LS+HP/LS/HP/EXTSelect between internal Loudspeaker (LS),Headphone (HP) or External loudspeaker (EXT).If the microphone is fitted with an internal loud-speaker, this can be activated by choosing HP.

TX SIDETONE ON/OFFWhen the function is ON the operator can hearhis own voice in the headphone when transmit-ting.If the microphone is fitted with an internal loud-speaker the function has to be set OFF to avoidfeedback.

ACKNOW.BEEP OFF/SHORT/NORM/LONGSet the length/intensity of the beep for eachtime the function keys are operated.

Page 20: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

20 99213_UM_TR710_D

Appendix A

TR-710 MENU FLOWCHART

Page 21: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 21

Page 22: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

22 99213_UM_TR710_D

Page 23: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 23

Page 24: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

24 99213_UM_TR710_D

NOTES:...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

Page 25: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

99213_UM_TR710_D 25

NOTES:...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

Page 26: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

26 99213_UM_TR710_D

NOTES:...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

...........................................................................................................

Page 27: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461
Page 28: 255724 manual tr710 innmat … · amendment no. incorp. by date page(s) version reason for change 1 07.04.05 7,8 a em4418 2 07.04.05 8 b em4440 3 07.04.05 17,18,22 c em4461

Jotron ASP.O. Box 54, NO-3280 Tjodalyng, NorwayTel: +47 33 13 97 00 | Fax: +47 33 12 67 80

www.jotron.com


Recommended