Asbestos Assessment Report
Residential Structure - 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003 Phase 47
PREPARED FOR:
Greenville County
301 University Ridge, Suite 4100
Greenville, South Carolina, 29601
PREPARED BY:
S&ME, Inc.
48 Brookfield Oaks Drive, Suite F
Greenville, SC 29607
December 27, 2018
Inspection Performed by:
Taylor Williams
SCDHEC License BI-01602
Inspection Date: November 30, 2018
Asbestos Identified No
Asbestos Design Required No
Asbestos Air Monitoring Required No
Attachment A
S&ME, Inc. | 48 Brookfield Oaks Drive, Suite F | Greenville, SC 29607 | p 864.297.9944 | www.smeinc.com
December 27, 2018
Greenville County
301 University Ridge, Suite 4100
Greenville, South Carolina 29601
Attention: Ms. Jessica Jordan
Reference: Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
Dear Ms. Jordan:
S&ME, Inc. (S&ME) has completed an asbestos assessment for the referenced property. The purpose of the
assessment is to identify asbestos-containing materials (ACMs) in the structure prior to demolition. Our
assessment was conducted in general accordance with our Proposal Number 42-1600890 dated July 20, 2016.
This work was authorized by the Greenville County Task Order # 04, dated August 1, 2018.
S&ME appreciates the opportunity to provide our asbestos assessment services to Greenville County. Please
contact us at your convenience if there are questions regarding the information contained in this report.
Sincerely,
S&ME, Inc.
Brian Mulholland Sherman Woodson, CIH, CSP
Staff Professional Senior Industrial Hygienist
[email protected] [email protected]
BM/SW T:\Projects\2018\ENV\4226-18-003_Greenville County Asbestos_Various Residents\Working_Documents\Phase 47 - 28 11th Street
ACM\28 11th Street Asbestos Report.docx
Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
December 27, 2018 ii
Table of Contents
1.0 Executive Summary .......................................................................................................... 1
2.0 Introduction ....................................................................................................................... 2
3.0 Site And Project Descriptions ........................................................................................ 2
3.1 Purpose ............................................................................................................................................ 2
3.2 Site Description ............................................................................................................................... 2
4.0 Asbestos Assessment ........................................................................................................ 3
4.1 Sampling and Analysis .................................................................................................................. 3
4.2 Assessment ...................................................................................................................................... 3
4.3 Findings and Results ...................................................................................................................... 4
5.0 Conclusions and Recommendations ............................................................................. 5
6.0 Assumptions and Limitations ........................................................................................ 4
Appendices Appendix I – Figures and Photographs
Appendix II – Table 1 – Summary of Asbestos Results
Appendix III – Asbestos Laboratory Reports
Appendix IV – Copy of Inspector’s License
Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
December 27, 2018 1
Executive Summary
S&ME performed an asbestos assessment of the structure located at 28 11th Street in Greenville, South Carolina.
The assessment was conducted by S&ME on November 30, 2018. This Executive Summary is intended as an
overview for the convenience of the reader. The complete report must be reviewed in its entirety prior to making
decisions regarding this site.
The subject structure is an approximately 1,150 square foot (SF) single-story residence built over a crawl space.
We understand the structure is scheduled for demolition. The interior is finished with drywall and plaster ceilings,
plaster ceilings, plaster walls, wood floors, floor tile, and vinyl sheet flooring. Exterior materials consist of vinyl
siding, wood framed windows, and a tin roof.
In addition a dog house and storage shed are located on the property. The dog house consists of wood siding
with no roof. The storage shed consists of metal siding with a metal roof. Neither contain any suspect ACMs.
The asbestos assessment included bulk sampling and laboratory analysis of suspect ACMs associated with the
interior and exterior of the structures. A total of 32 samples were collected including drywall with associated joint
compound, plaster, vinyl sheet flooring, floor tile, window glazing compound material, ceiling tile, and textured
ceiling.
The Environmental Protection Agency (EPA) and South Carolina Department of Health and Environmental Control
(SCDHEC) define materials as asbestos-containing (ACMs) if an asbestos content of one percent or greater (> 1%)
is detected in a representative sample.
No asbestos-containing materials were identified in the residential structure, dog house or storage shed
structures.
It should also be noted that the following materials contains less than 1% asbestos:
• Mastic associated with square pattern vinyl sheet flooring, located in bedroom #1 as a bottom layer –
approximately 400 SF.
Although this material is not considered an ACM by SCDHEC and EPA, OSHA regulations apply to workers who
may potentially come in contact with or disturb these materials. Therefore, S&ME recommends this material be
treated as ACM and also be removed by a SCDHEC licensed abatement contractor prior to demolition.
This summary is for convenience only and should not be relied upon without first reading the full contents of this
report, including appended materials.
Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
December 27, 2018 2
1.0 Introduction
S&ME was contracted by Greenville County to perform an asbestos assessment of the structure located at 28 11th
Street in Greenville, South Carolina. S&ME performed the asbestos assessment on November 30, 2018. This
assessment consisted of observing for, sampling, and analyzing suspect ACM that may be disturbed during future
demolition.
The scope of this assessment fulfills the requirements of the United States Environmental Protection Agency
(USEPA) National Emissions Standards for Hazardous Air Pollutants (NESHAPS) asbestos regulation, 40 CFR, Part
61, Subpart M, and SCDHEC Regulation 61-86.1, which requires an asbestos assessment of buildings scheduled for
renovation or demolition.
2.0 Site and Project Descriptions
2.1 Purpose
The assessment was performed to identify ACMs, prior to disturbing building materials during demolition
activities. The assessment included the interior and exterior of the building including roofing materials of the
residential structure located on the property. No additional structures were observed on the property. An
assessment strategy appropriate for this purpose was presented in our proposal and this report should be
interpreted only with regard to the specific purpose indicated.
2.2 Site Description
The subject structure is an approximately 1,150 SF single-story residence built over a crawl space foundation. We
understand the structure is scheduled for demolition. The interior is finished with drywall and plaster ceilings,
plaster ceilings, plaster walls, wood floors, floor tile, and vinyl sheet flooring. Exterior materials consist of vinyl
siding, wood framed windows, and a tin roof. Rock wool insulation is present in the attic. Fiberglass insulation is
present on the HVAC duct work.
Non-suspect materials observed and not sampled in the building include: glass, cement, fiberglass insulation, rock
wool insulation, and concrete.
The general layout of the structure is depicted in Figure 1 in Appendix I. Photographs of the suspect samples are
also included in Appendix I. Table 1, Asbestos Results Summary, is found in Appendix II, and presents a summary
of the suspect materials, material friability, condition, potential for disturbance, quantity, and asbestos analysis of
the samples collected. The laboratory results are located in Appendix II.
Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
December 27, 2018 3
3.0 Asbestos Assessment
3.1 Sampling and Analysis
The assessment was performed by observing and sampling suspect ACMs associated with the accessible areas of
the subject building. The possibility exists that suspect materials were undetected in inaccessible areas such as
wall voids. If additional suspect ACMs not identified in this report are discovered during destructive activities, bulk
samples must be collected by a SCDHEC licensed inspector and analyzed for asbestos content prior to disturbance
or disposal of the suspect materials.
A sampling strategy was developed to provide representative samples in accordance with the SCDHEC and the
EPA. Bulk samples of suspect ACMs were collected by an SCDHEC licensed inspector. The bulk PLM and TEM
samples were submitted through chain-of-custody procedures to Eurofins CEI asbestos laboratory in Cary, North
Carolina for analysis of asbestos type and content. The laboratories are accredited by the National Voluntary
Laboratory Accreditation Program (NVLAP), which is administered by the National Institute of Standards and
Technology.
Polarized Light Microscopy (PLM)
The suspect materials were analyzed by trained microscopists using PLM techniques coupled with dispersion
staining in accordance with EPA Test Method Title 40 Code of Federal Regulations, Chapter I (1-1-87 edition), Part
763, Subpart F-APPENDIX A. This method identifies asbestos mineral fibers based on six optical characteristics:
morphology, birefringence, refractive index, extinction angle, sign of elongation and dispersion staining colors.
The laboratory analysis reports the specific type of asbestos identified (there are six asbestos minerals) and the
percentage of asbestos present.
Transmission Electron Microscopy (TEM)
Suspect non-friable organically bound materials, exhibiting negative results via PLM analysis, were analyzed by
trained microscopists by TEM using EPA 600 Method in accordance with ASTM E2356. Typical examples of this
material include, but are not limited to floor tile, mastic adhesives, sheet flooring (linoleum), roofing materials,
glazing, caulking, duct mastic and cove base mastic.
3.2 Assessment
The sampled materials were assessed based on condition (good, fair or poor) and potential for disturbance due to
the scheduled renovation/demolition. The sampled materials were also categorized based on the EPA’s National
Emission Standards for Hazardous Air Pollutants (NESHAP) regulation categories. Friable ACM is classified as an
ACM that can be crumbled to a powder by moderate hand pressure. Non-friable ACM is classified as either
Category I Non-friable ACM or Category II Non-friable ACM. Category I and Category II Non-friable ACM are
distinguished from each other by their fiber release potential when damaged. Generally, Category I Non-friable
ACM, which by definition includes intact ACM roofing materials, gaskets, packing, resilient floor coverings and
floor mastics, is less likely to become friable and release fibers in a damaged state. Category II Non-friable ACM
include all other non-friable ACM excluding Category I that have a high probability of being rendered friable
Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
December 27, 2018 4
during removal activities or demolition. All Friable ACM, Category I Non-friable ACM that has become friable,
Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or
Category II Non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or
reduced to powder by the forces expected to act on the material in the course of demolition or renovation
operations are considered to be a Regulated Asbestos-Containing Material (RACM).
3.3 Findings and Results
The EPA and SCDHEC define materials as asbestos containing when an asbestos content >1% is detected in a
representative sample.
No asbestos-containing materials were identified in the residential structure, dog house or storage shed
structures.
In accordance with SCDHEC Regulation 61-86.1, TEM analysis was performed on one sample of each of the non-
friable, organically-bound (NOB) materials that displayed a result of no asbestos detected or less than 1%
asbestos via PLM analysis. NOBs consist of materials such as vinyl floor tiles, vinyl baseboards and mastics. Please
refer to Table 1 in Appendix II for more detail regarding which samples of NOB materials were submitted for TEM
analysis.
It should also be noted that the following materials contains less than 1% asbestos:
• Mastic associated with square pattern vinyl sheet flooring, located in bedroom #1 as a bottom layer –
approximately 400 SF.
Although this material is not considered an ACM by SCDHEC and EPA, OSHA regulations apply to workers who
may potentially come in contact with or disturb these materials. Therefore, S&ME recommends this material be
treated as ACM and also be removed by a SCDHEC licensed abatement contractor prior to demolition.
4.0 Assumptions and Limitations
This report is provided for the sole use of the Client. Use of this report by any other parties will be at such party’s
sole risk, and S&ME disclaims liability for any such use or reliance by third parties. The results presented in this
report are indicative of conditions only during the time of the sampling period and of the specific areas
referenced. Under no circumstances is this report to be used as a bidding document, or as a project design or
specification.
S&ME performed the services in accordance with generally accepted practices of reputable environmental
consultants undertaking similar studies at the same time and in the same geographical area. S&ME has
endeavored to meet this standard of care. No other warranty, expressed or implied, is intended or made with
respect to this report or S&ME’s services. Users of this report should consider the scope and limitations related to
these services when developing opinions as to risks associated with the site.
Asbestos Assessment Report
Residential Structure – 28 11th Street
Greenville, South Carolina
S&ME Project No. 4226-18-003, Phase 47
December 27, 2018 5
The possibility exists that suspect materials were undetected in inaccessible or concealed areas such as under
carpeting or multiple flooring layers, and inside pipe chases or wall voids. If additional suspect materials are
discovered during the planned destructive activities, bulk samples must be collected by an asbestos inspector and
analyzed for asbestos content.
5.0 Conclusions and Recommendations
No asbestos-containing materials were identified in the building. Therefore, no specific recommendations are
made at this time. If the structure remains unchanged from the condition observed during the performance of
this assessment, the report will remain valid for three years.
This report should be provided to the contractor(s) to assist with compliance with applicable State and Federal
regulations. If additional suspect materials are discovered during renovation activities, bulk samples must be
collected and analyzed for asbestos content prior to continuation of work.
FIGURE NO.
CHECKED BY: SW 28 11th Street1
DRAWN BY: TRW Greenville, South Carolina
SCALE: NTS Approximate Asbestos Sample Locations
DATE: 11/30/2018 Project Number : 4226-18-003 Phase 47
D1
C1
Kitchen
Structure #3Structure #2
Back Porch
Living Room
C2
D2
H2Bedroom #1
E2
Front Porch
I3
A3, B3
F5
A1, B1
E1
A2, B2
J2
J1
J3
G1
Bedroom #2
Bathroom
Foyer
F1
F2
D3
I1
F4
E3
G3, I2
G2
F3
H1
H3
C3
Asbestos Assessment
28 11th Street
Greenville, South Carolina
S&ME Project # 4226-18-003 Phase 47
Taken by: Taylor Williams Date Taken: 11/30/2018
1
1 General view of the front of the main structure. 2 General view of the back of the main structure.
3 General view of the crawl space of the main structure. 4 General view of the roof of the main structure.
Asbestos Assessment
28 11th Street
Greenville, South Carolina
S&ME Project # 4226-18-003 Phase 47
Taken by: Taylor Williams Date Taken: 11/30/2018
2
5 General view of Structure #2. . 6 General view of Structure #3.
7 General interior view of Structure #3. 8 Sample A: Rock pattern vinyl sheet flooring (top layer).
No asbestos detected.
Asbestos Assessment
28 11th Street
Greenville, South Carolina
S&ME Project # 4226-18-003 Phase 47
Taken by: Taylor Williams Date Taken: 11/30/2018
3
9 Sample B: Square pattern vinyl sheet flooring (bottom layer).
No asbestos detected. 10 Sample C: 18-inch tan floor tile with yellow mastic.
No asbestos detected.
11 Sample D: 18-inch gray floor tile with yellow mastic.
No asbestos detected. 12 Sample E: 18-inch brown rock pattern floor tile with black mastic.
No asbestos detected.
Asbestos Assessment
28 11th Street
Greenville, South Carolina
S&ME Project # 4226-18-003 Phase 47
Taken by: Taylor Williams Date Taken: 11/30/2018
4
13 Sample F: Plaster.
No asbestos detected. 14 Sample G: Drywall and joint compound.
No asbestos detected.
15 Sample H: 2’ x 2’ grooved ceiling tile.
No asbestos detected. 16 Sample I: Textured ceiling.
No asbestos detected.
Asbestos Assessment
28 11th Street
Greenville, South Carolina
S&ME Project # 4226-18-003 Phase 47
Taken by: Taylor Williams Date Taken: 11/30/2018
5
No Photo
17 Sample J: Window glazing.
No asbestos detected. 18
No Photo No Photo
19 20
A1
A2
A3
(TEM)
B1
B2
B3
(TEM)
C1
C2
C3
(TEM)
D1
D2
D3
(TEM)
E1
E2
E3
(TEM)
F1
F2
F3
F4
F5
G1
G2
G3
H1
H2
H3
I1
I2
I3
LPD 75 SF
Drywall - NAD
Joint Compound - NADFriable Good LPD 600 SF
Table 1
Asbestos Results Summary
Greenville, South Carolina
Estimated
Quantity
Sample
NumberAnalytical Results
S&ME Project No. 4226-18-003 Phase 47
Friable /
Non-Friable
Current
Condition
Potential for
Disturbance
28 11th Street
Sample Description Location
18-inch Tan Floor Tile
with Yellow Mastic
Foyer - patterned floor tile
layout
Tile - NAD
Mastic - NAD
18-inch Gray Floor Tile
with Yellow Mastic
Foyer and Kitchen -
patterned floor tile layout
Tile - NAD
Mastic - NAD
Plaster Skim Coat - NAD
Base Coat - NAD
Walls: Bedroom #2 and Hallway
Ceilings: Both Bedrooms and
Kitchen
Drywall and Joint CompoundCeilings: Living Room, Hallway,
and Bathroom
18-inch Brown Rock Pattern Floor
Tile with Brown Mastic
Kitchen - patterned floor tile
layout
Tile - NAD
Mastic - NAD
25 SFNon-Friable Good LPD
Non-Friable Good LPD 150 SF
1500 SFLPDGoodFriable
Non-Friable Good
LPD 400 SF
Rock Pattern Vinyl Sheet Flooring
(top layer)Bedroom #1
Vinyl Flooring - NAD
Mastic - NADNon-Friable Damaged PD 400 SF
Square Pattern Vinyl Sheet
Flooring (bottom layer)Bedroom #1
Vinyl Flooring - NAD
Mastic - < 1% ChrysotileNon-Friable Good
Foyer NAD Friable Good2' x 2' Carpet Ceiling Tile
Textured Ceiling
LPD 40 SF
Living Room NAD Friable Good LPD 350 SF
Table 1
Asbestos Results Summary
Greenville, South Carolina
Estimated
Quantity
Sample
NumberAnalytical Results
S&ME Project No. 4226-18-003 Phase 47
Friable /
Non-Friable
Current
Condition
Potential for
Disturbance
28 11th Street
Sample Description Location
J1
J2
J3
(TEM)
1) Quantities listed above are estimates to be used for inspection purposes only.
2) Samples shown in bold are designated as asbestos-containing materials (ACMs).
3) Sampled by Taylor Williams, SCDHEC License No. 01602.
NAD - No Asbestos Detected
Samples analyzed by PLM - Polarized Light Microscopy.
PACM - Presumed Asbestos Containing Material
NOTES:
SF - square feet
LF - linear feet
CF - cubic feet
Window Glazing Windows 250 LFLPDGoodNon-FriableNAD
December 4, 2018
S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
CLIENT PROJECT: 28 11th Street, 4226-18-003 Phase 47CEI LAB CODE: A1816175
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory onDecember 3, 2018. The samples were analyzed for asbestos using polarizing light microscopy(PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials(ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1%asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIHLaboratory Director
Kind Regards,
ASBESTOS ANALYTICAL REPORTBy: Polarized Light Microscopy
Prepared for
S&ME
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
28 11th Street, 4226-18-003 Phase 47
A1816175
26
12/04/18
Asbestos Report SummaryBy: POLARIZING LIGHT MICROSCOPY
PROJECT: 28 11th Street, 4226-18-003 Phase 47 LAB CODE: A1816175
Client ID Lab ID Color Sample DescriptionASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Layer 1 A199271 Tan,Black Vinyl Flooring None DetectedA1
Layer 2 A199271 Brown Mastic None Detected
Layer 1 A199272 Tan,Black Vinyl Flooring None DetectedA2
Layer 2 A199272 Brown Mastic None Detected
Layer 1 A199273 Sample Submitted for TEMAnalysis
A3
Layer 2 A199273 Sample Submitted for TEMAnalysis
Layer 1 A199274 Tan,Green Vinyl Flooring None DetectedB1
Layer 2 A199274 Brown Mastic None Detected
Layer 1 A199275 Tan,Green Vinyl Flooring None DetectedB2
Layer 2 A199275 Brown Mastic None Detected
Layer 1 A199276 Sample Submitted for TEMAnalysis
B3
Layer 2 A199276 Sample Submitted for TEMAnalysis
A199277A Tan,Gray Floor Tile None DetectedC1
A199277B Yellow Mastic None Detected
A199278A Tan,Gray Floor Tile None DetectedC2
A199278B Yellow Mastic None Detected
A199279A Sample Submitted for TEMAnalysis
C3
A199279B Sample Submitted for TEMAnalysis
A199280A Gray Floor Tile None DetectedD1
A199280B Yellow Mastic None Detected
A199281A Gray Floor Tile None DetectedD2
A199281B Yellow Mastic None Detected
A199282A Sample Submitted for TEMAnalysis
D3
A199282B Sample Submitted for TEMAnalysis
A199283A Brown Floor Tile None DetectedE1
Page 1 of 3
Asbestos Report SummaryBy: POLARIZING LIGHT MICROSCOPY
PROJECT: 28 11th Street, 4226-18-003 Phase 47 LAB CODE: A1816175
Client ID Lab ID Color Sample DescriptionASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
A199283B Brown Mastic None Detected
A199284A Brown Floor Tile None DetectedE2
A199284B Brown Mastic None Detected
A199285A Sample Submitted for TEMAnalysis
E3
A199285B Sample Submitted for TEMAnalysis
Layer 1 A199286 White Plaster Skim Coat None DetectedF1
Layer 2 A199286 Tan Plaster Base Coat None Detected
Layer 1 A199287 White Plaster Skim Coat None DetectedF2
Layer 2 A199287 Tan Plaster Base Coat None Detected
Layer 1 A199288 White Plaster Skim Coat None DetectedF3
Layer 2 A199288 Tan Plaster Base Coat None Detected
Layer 1 A199289 White Plaster Skim Coat None DetectedF4
Layer 2 A199289 Tan Plaster Base Coat None Detected
Layer 1 A199290 White Plaster Skim Coat None DetectedF5
Layer 2 A199290 Tan Plaster Base Coat None Detected
Layer 1 A199291 White,Tan Drywall None DetectedG1
Layer 2 A199291 White Joint Compound None Detected
Layer 1 A199292 White,Tan Drywall None DetectedG2
Layer 2 A199292 White Joint Compound None Detected
Layer 1 A199293 White,Tan Drywall None DetectedG3
Layer 2 A199293 White Joint Compound None Detected
A199294 Silver,Gray Ceiling Tile None DetectedH1
A199295 Silver,Gray Ceiling Tile None DetectedH2
A199296 Silver,Gray Ceiling Tile None DetectedH3
A199297 Off-white Texture None DetectedI1
A199298 Off-white Texture None DetectedI2
A199299 Off-white Texture None DetectedI3
A199300 White Window Glazing None DetectedJ1
A199301 White Window Glazing None DetectedJ2
Page 2 of 3
Asbestos Report SummaryBy: POLARIZING LIGHT MICROSCOPY
PROJECT: 28 11th Street, 4226-18-003 Phase 47 LAB CODE: A1816175
Client ID Lab ID Color Sample DescriptionASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
A199302 Sample Submitted for TEMAnalysis
J3
Page 3 of 3
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
Tan,BlackA1
A199271
60%Heterogeneous
FibrousBound
20%20%
Cellulose VinylTar
None DetectedLayer 1
Vinyl Flooring
BrownMastic
A199271Homogeneous
Non-fibrousBound
100% Mastic None DetectedLayer 2
Tan,BlackA2
A199272
60%Heterogeneous
FibrousBound
20%20%
Cellulose VinylTar
None DetectedLayer 1
Vinyl Flooring
BrownMastic
A199272Homogeneous
Non-fibrousBound
100% Mastic None DetectedLayer 2
A3
A199273Layer 1
Sample Submitted forTEM Analysis
Sample Submitted forTEM AnalysisA199273
Layer 2
Tan,GreenB1
A199274
60%Heterogeneous
FibrousBound
20%20%
Cellulose VinylTar
None DetectedLayer 1
Vinyl Flooring
BrownMastic
A199274Homogeneous
Non-fibrousBound
100% Mastic None DetectedLayer 2
Page 1 of 8
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
Tan,GreenB2
A199275
60%Heterogeneous
FibrousBound
20%20%
Cellulose VinylTar
None DetectedLayer 1
Vinyl Flooring
BrownMastic
A199275Homogeneous
Non-fibrousBound
100% Mastic None DetectedLayer 2
B3
A199276Layer 1
Sample Submitted forTEM Analysis
Sample Submitted forTEM AnalysisA199276
Layer 2
Tan,GrayFloor TileC1
A199277AHomogeneous
Non-fibrousBound
100% Vinyl None Detected
YellowMasticA199277B Homogeneous
Non-fibrousBound
100% Mastic None Detected
Tan,GrayFloor TileC2
A199278AHomogeneous
Non-fibrousBound
100% Vinyl None Detected
YellowMasticA199278B Homogeneous
Non-fibrousBound
100% Mastic None Detected
Page 2 of 8
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
Sample Submitted forTEM Analysis
C3A199279A
Sample Submitted forTEM Analysis
A199279B
GrayFloor TileD1
A199280AHomogeneous
Non-fibrousBound
100% Vinyl None Detected
YellowMasticA199280B Homogeneous
Non-fibrousBound
100% Mastic None Detected
GrayFloor TileD2
A199281AHomogeneous
Non-fibrousBound
100% Vinyl None Detected
YellowMasticA199281B Homogeneous
Non-fibrousBound
100% Mastic None Detected
Sample Submitted forTEM Analysis
D3A199282A
Sample Submitted forTEM Analysis
A199282B
BrownFloor TileE1
A199283AHomogeneous
Non-fibrousBound
100% Vinyl None Detected
Page 3 of 8
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
BrownMasticA199283B Homogeneous
Non-fibrousBound
100% Mastic None Detected
BrownFloor TileE2
A199284AHomogeneous
Non-fibrousBound
100% Vinyl None Detected
BrownMasticA199284B Homogeneous
Non-fibrousBound
100% Mastic None Detected
Sample Submitted forTEM Analysis
E3A199285A
Sample Submitted forTEM Analysis
A199285B
WhiteF1
A199286
Homogeneous
Non-fibrousBound
60%35%5%
BinderSilicatesPaint
None DetectedLayer 1
Plaster Skim Coat
TanPlaster Base Coat
A199286Homogeneous
Non-fibrousBound
40%60%
BinderSilicates
None DetectedLayer 2
WhiteF2
A199287
Homogeneous
Non-fibrousBound
60%35%5%
BinderSilicatesPaint
None DetectedLayer 1
Plaster Skim Coat
Page 4 of 8
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
TanPlaster Base Coat
A199287Homogeneous
Non-fibrousBound
40%60%
BinderSilicates
None DetectedLayer 2
WhiteF3
A199288
Homogeneous
Non-fibrousBound
60%35%5%
BinderSilicatesPaint
None DetectedLayer 1
Plaster Skim Coat
TanPlaster Base Coat
A199288Homogeneous
Non-fibrousBound
40%60%
BinderSilicates
None DetectedLayer 2
WhiteF4
A199289
Homogeneous
Non-fibrousBound
60%35%5%
BinderSilicatesPaint
None DetectedLayer 1
Plaster Skim Coat
TanPlaster Base Coat
A199289Homogeneous
Non-fibrousBound
40%60%
BinderSilicates
None DetectedLayer 2
WhiteF5
A199290
Homogeneous
Non-fibrousBound
60%35%5%
BinderSilicatesPaint
None DetectedLayer 1
Plaster Skim Coat
TanPlaster Base Coat
A199290Homogeneous
Non-fibrousBound
40%60%
BinderSilicates
None DetectedLayer 2
Page 5 of 8
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
White,TanG1
A199291
20%Heterogeneous
FibrousBound
80%Cellulose Gypsum None DetectedLayer 1
Drywall
WhiteJoint Compound
A199291Homogeneous
Non-fibrousBound
60%40%<1%
BinderCalc CarbPaint
None DetectedLayer 2
White,TanG2
A199292
20%Heterogeneous
FibrousBound
80%Cellulose Gypsum None DetectedLayer 1
Drywall
WhiteJoint Compound
A199292Homogeneous
Non-fibrousBound
60%40%<1%
BinderCalc CarbPaint
None DetectedLayer 2
White,TanG3
A199293
20%Heterogeneous
FibrousBound
80%Cellulose Gypsum None DetectedLayer 1
Drywall
WhiteJoint Compound
A199293Homogeneous
Non-fibrousBound
60%40%<1%
BinderCalc CarbPaint
None DetectedLayer 2
Silver,GrayCeiling TileH1
A19929410%80%
Heterogeneous
FibrousLoosely Bound
10%CelluloseMineral Wool
Metal Foil None Detected
Page 6 of 8
ASBESTOS BULK ANALYSISBy: POLARIZING LIGHT MICROSCOPY
Lab Code: A1816175Date Received: 12-03-18Date Analyzed: 12-04-18Date Reported: 12-04-18
Client IDLab ID
LabAttributes
LabDescription
ASBESTOS%
ASBESTOS BULK PLM, EPA 600 METHODNON-ASBESTOS COMPONENTS
Non-Fibrous
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
Fibrous
Silver,GrayCeiling TileH2
A19929510%80%
Heterogeneous
FibrousLoosely Bound
10%CelluloseMineral Wool
Metal Foil None Detected
Silver,GrayCeiling TileH3
A19929610%80%
Heterogeneous
FibrousLoosely Bound
10%CelluloseMineral Wool
Metal Foil None Detected
Off-whiteTextureI1
A1992975%Homogeneous
Non-fibrousBound
55%35%5%
Cellulose BinderFoamPaint
None Detected
Off-whiteTextureI2
A1992985%Homogeneous
Non-fibrousBound
55%35%5%
Cellulose BinderFoamPaint
None Detected
Off-whiteTextureI3
A1992995%Homogeneous
Non-fibrousBound
55%35%5%
Cellulose BinderFoamPaint
None Detected
WhiteWindow GlazingJ1
A199300Homogeneous
Non-fibrousBound
100% Binder None Detected
WhiteWindow GlazingJ2
A199301Homogeneous
Non-fibrousBound
100% Binder None Detected
Sample Submitted forTEM Analysis
J3A199302
Page 7 of 8
LEGEND: Non-Anth = Non-Asbestiform AnthophylliteNon-Trem = Non-Asbestiform TremoliteCalc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such asvinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends thatall NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by TransmissionElectron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos isnot covered under NVLAP accreditation. Estimated measurement of uncertainty is available onrequest.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regardingthe accuracy of client submitted information in preparing and presenting analytical results.Interpretation of the analytical results is the sole responsibility of the client. Samples were received inacceptable condition unless otherwise noted. This report may not be used by the client to claimproduct endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID, location, volume and area as well asdate and time of sampling.
Page 8 of 8
ANALYST: APPROVED BY:Tianbao Bai, Ph.D., CIHLaboratory Director
Megan Fisher
December 6, 2018
S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
CLIENT PROJECT: 28 11th Street, 4226-18-003 Phase 47LAB CODE: T182889
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory onDecember 4, 2018. The samples were analyzed for asbestos using transmission electronmicroscopy (TEM) per Chatfield Method.
Sample results containing > 1% asbestos are considered asbestos-containing materials(ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfieldmethod is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIHLaboratory Director
Kind Regards,
ASBESTOS ANALYTICAL REPORTBy: Transmission Electron Microscopy
Prepared for
S&ME
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk ChatfieldEPA 600 / R93 / 116
REPORT DATE:
28 11th Street, 4226-18-003 Phase 47
T182889
12/06/18
ASBESTOS BULK ANALYSISBy: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T182889Date Received: 12-04-18Date Analyzed: 12-05-18Date Reported: 12-06-18
Client IDLab ID
MaterialDescription
TEM BULK CHATFIELD / EPA 600 / R93 / 116
Client: S&ME48 Brookfield Oaks Dr, Suite FGreenville, SC 29607
Project: 28 11th Street, 4226-18-003 Phase 47
SampleWeight
(g)
OrganicMaterial
%
Acid SolubleMaterial
%
Acid InsolubleMaterial
%Asbestos
%
T88542A3 Vinyl Flooring 0.212 71.2 28.3 .5 None
Detected
T88543A3 Mastic 0.109 76.1 22.9 1 None
Detected
T88544B3 Vinyl Flooring 0.414 69.8 25.1 5.1 None
Detected
T88545B3 Mastic 0.107 76.6 22.4 1 <1% Chrysotile
T88546C3 Floor Tile 0.492 36.4 57.9 5.7 None
Detected
T88547C3 Mastic 0.135 86.7 9.6 3.7 None
Detected
T88548D3 Floor Tile 0.585 49.1 49.7 1.2 None
Detected
T88549D3 Mastic 0.138 84.8 13.8 1.4 None
Detected
T88550E3 Floor Tile 0.423 45.4 50.1 4.5 None
Detected
T88551E3 Mastic 0.192 90.6 4.2 5.2 None
Detected
T88552J3 Window Glazing 0.582 12.4 84.9 2.7 None
Detected
Page 1 of 2
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regardingthe accuracy of client submitted information in preparing and presenting analytical results.Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement ofuncertainty is available on request. Samples were received in acceptable condition unless otherwisenoted.
Information provided by customer includes customer sample ID, location, volume and area as well asdate and time of sampling.
Page 2 of 2
ANALYST: APPROVED BY:Tianbao Bai, Ph.D., CIHLaboratory Director
Brunilda Gjoka