HYBRID 3-PHASE AIO WWW.FOX-ESS.COM DATASHEET Three-Phase Hybrid AIO AIO-H3-5.0-E / 6.0-E / 8.0-E / 10.0-E BATTERY EXPANSION EASY UPGRADE + For more about the Fox range of storage solu- tions, visit: FOX storage solutions are available with advanced and intuitive app based remote control and monitoring functionality. UNBALANCED LOADS SUPPORTED EPS OPTION A high-performancehigh-efficiency system with 10 kWh of storage capacity and up to 6kW charge/discharge rate
Transcript
  • HYBRID3-PHASE AIO

    WWW.FOX-ESS.COM

    D A T A S H E E TThree-Phase Hybrid AIO

    AIO-H3-5.0-E / 6.0-E / 8.0-E / 10.0-E

    BATTERY EXPANSIONEASY UPGRADE

    +

    For more about the Fox range of storage solu-tions, visit:

    FOX storage solutions are available with advanced and intuitive app based remote control and monitoring functionality.

    UNBALANCED LOADS SUPPORTEDEPS OPTION

    A high-performance,high-efficiencysystem with 10 kWh of storage capacityand up to 6kW charge/discharge rate

  • VERSION 2.0 | 03/11/2020

    TECHNICAL SPECIFICATIONSModel AIO-H3-5.0-E AIO-H3-6.0-E AIO-H3-8.0-E AIO-H3-10.0-E

    Max. recommended DC power [W] 7500 9000 12000 15000

    Max. DC voltage [V]

    Nominal DC opera�ng voltage [V]

    Max. input current (input A/input B) [A] 13/13 13/13 13/13 25/13

    Start-Up voltage [V]

    MPPT voltage range [Vdc]

    No. of MPP trackers

    Strings per MPP tracker A:1/B:1 A:1/B:1 A:2/B:1 A:2/B:1

    MPPT voltage range (Full load) [Vdc]

    Nominal AC power [VA] 5000 6000 8000 10000

    Max. apparent AC power [VA] 5500 6600 8800 11000

    Rated grid voltage (AC voltage range) [V]

    Rated grid Frequency [Hz]

    Nominal AC current [A] 7.2 8.7 11.6 14.5

    Max. AC current [A] 8.0 9.6 12.8 15.9

    Displacement power factor

    Total harmonic distor�on (THDi, rated power)

    Unbalance output

    Parallel opera�on

    Nominal AC power [VA] 5000 6000 8000 10000

    Nominal AC current [A] 7.2 8.7 11.6 14.5

    Max. AC current [A] 8.0 9.6 12.8 15.9

    Rated grid voltage (AC voltage range) [V]

    Rated grid Frequency [Hz]

    Power factor

    Ba�ery capacity [kWh]

    Ba�ery voltage range [V]

    Max. charge/discharge power [W] 5000 6000 8000 10000

    Max. charge/discharge current [A]

    Communica�on interfaces

    Reverse connect protec�on

    Nominal AC power [W] 5000 6000 8000 10000

    Max. AC power (60s) [VA] 10000 12000 14000 15000

    EPS rated voltage [V], Frequency [Hz]

    EPS rated current (@230VAC) [A] 7.2 8.7 11.6 14.5

    Switch �me [s]

    Total harmonic distor�on (THDv, linear Load)Parallel opera�on

    MPPT efficiency

    Euro-efficiency

    Max. efficiency

    Ba�ery Charge Efficiency

    Ba�ery Discharge Efficiency

    Internal consump�on (night) [W]

    Idle mode

    Safety

    EMC

    Grid rules

    Protec�on class

    Opera�ng temperature range [°C]

    Humidity [%]

    Al�tude [m]

    Storage temperature [°C]

    Noise emission (typical) [dB]

    Over voltage category

    Dimensions (HxWxD) [mm]

    Weight [kg]

    Cooling concept

    Topology

    Communica�on

    180V

    2

    99.90%

    97.00%

    97.80%

    INPUT PV

    1000

    720

    26

    OUTPUT AC

    Up to 11.2kWh

    180-800

    Yes

    220/230/240

    50/60, ±5

    0.8 leading to 0.8 lagging


Recommended