AutoChief ®600
Lever Telegraph Unit (LTU11)
Functions
Telegraph positions
The following 11 telegraph steps are
indicated with light diodes:.
• Ahead:Deadslow,slow,half,full,
navigationfull
• Stop
• Astern:Deadslow,slow,half,full,
emergency astern
Additionally,thelevercanbemoved
betweenthestepsaswellforadjusting
command.Itisalsopossibletousea
netuningmechanismonthetouch
display.
Sub telegraph modes
Thesub-telegraphfunctionsareused
toinformtheenginecrewabouttheir
stateofalert,andsubsequentneedfor
propulsiveandelectricpower.
•Finishedwithengine(FWE)•Stand-by
•Atsea
Description
AcombinedlevertypeEngine
Telegraph&speedsetunitenablesthe
operatoronthebridgetobeindirect
commandoftheshipbyproviding
speed and rotation control of the main
engine.Communicationisestablished
betweenthebridge,theenginecontrol
room and local stand via the telegraph
system.
Theunitisdesignedwithatouch
sensitivescreen,apush-button,and
acombinedtelegraphandspeedset
leverwithredundantspeedsettothe
Governor.
Available control locations
•Bridge
•Enginecontrolroom(ECR)• Optional,otherlocations
Command transfer
Thecommandtransferfunctioncanbe
foundonthetouchsensitivedisplay.
Buttonsareusedforbothindicating
currentcommandpositionand
command transfer.
Emergency stop
TheEmergencyStoppush-button
islocatedunderaprotectivecover.
This will activate the emergency stop
system in the main engine safety
system.
Touch screen lock
Whenactivatedtheleverwillmove
backtolockedsettingifmoved.
Wrong Way indicator
TheLTUisequippedwithaWrongWayindicator.Thealarmisreleasedif
the engine does not rotate in ordered
direction,whileinengineroom
control.
7/29/2019 367938-LTU11 (1)
http://slidepdf.com/reader/full/367938-ltu11-1 2/2
Technical Specifcations
367938 C
Kongsberg Maritime AS
Bekkajordet 8A
P.O.Box 1009
NO-3189 Horten
Norway
Telephone: +47 815 73 700
Telefax: +47 850 28 028
www.kongsberg.com
Supply voltage
• 2x18-32VDCDual&
independent.
Weight of unit
• 3.8kg
Mounting
• 4pcsclampwithanutlock.Max.
consoleplatethickness8.5mm.
Isolation
• PowerBPU11/LTU11:Isolated/
oatingfrommodulechassis.
• BPU11isolatedfromLTU11.
• CAN:Individuallyisolated
• EmergencyStop:Isolated
Power consumption
• LTU1112W
• BPU112.4W
Copyright © 2013 Kongsberg Maritime AS – All rights reserved
Specifcations may be subject to change without prior notice
Connections, pluggable
• I/O2terminals2.5mm2
• Power4terminals2.5mm2
• CANbus4terminals2.5mm2
Communication• 2CANportsforcommunication
with Host.
Type Approval
Tobeestablishedwith:
DNV,LRS,BV,GL,RINA,NK,ABS,
KR,MRS(Russia),CCS(China)
Part number
• 364330
IP Code
•IP22
Environment tests
• IACSE10
• IEC60945
Mechanical environment
• 1g
Operational temperature
• -15ºCto+70ºC
Storage temperature
• -25ºCto+70ºC
Max relative humidity
• 96%non-condensing