+ All Categories
Home > Documents > 3/8 Elima-Matic Bolted Plastic E8 Service & Operating ... · • Typical Installation Guide •...

3/8 Elima-Matic Bolted Plastic E8 Service & Operating ... · • Typical Installation Guide •...

Date post: 20-May-2018
Category:
Upload: ngoduong
View: 215 times
Download: 0 times
Share this document with a friend
14
Versa-Matic E8 Plastic Pump • Polypropylene • Kynar 3/8" Elima-Matic Bolted Plastic with Non-Metallic Center Sections E8 VERSA-MATIC ® • Warren Rupp, Inc. • A Unit of IDEX Corporation 800 North Main Street, Mansfield, OH 44902 USA • Phone: (419) 526-7296 • www.versamatic.com © Copyright 2012 Warren Rupp, Inc. All rights reserved 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW 4: WARRANTY Service & Operating Manual Original Instructions
Transcript

Ver

sa-M

atic

E8 Plastic Pump• Polypropylene• Kynar

3/8" Elima-Matic Bolted PlasticwithNon-MetallicCenterSections E8

VERSA-MATIC® •WarrenRupp,Inc.•AUnitofIDEXCorporation800NorthMainStreet,Mansfield,OH44902USA•Phone:(419)526-7296•www.versamatic.com

© Copyright 2012 Warren Rupp, Inc. All rights reserved

1: P

UMP

SPEC

S2:

INST

AL &

OP

3: E

XP V

IEW

4: W

ARRA

NTY

Serv

ice

& O

per

ati

ng

Ma

nu

al

Orig

inal

Inst

ruct

ions

e8nmdlCsm-rev0912www.versamatic.com

IMPORTANT

Read the safety warnings and instructions in this manual before pump installation and start-up. Failure to comply with the recommendations stated in this manual could damage the pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear protection.

Before maintenance or repair, shut off the compressed air line, bleed the pressure, and disconnect the air line from the pump. Be certain that approved eye protection and protective clothing are worn at all times. Failure to follow these recommendations may result in serious injury or death.

To be fully groundable, the pumps must be ATEX Compliant. Refer to the nomenclature page for ordering information.

Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.

To reduce the risk of static electrical sparking, this pump must be grounded. Check the local electrical code for detailed grounding instruction and the type of equipment required.

Refer to nomenclature page for ordering information.

When the pump is used for materials that tend to settle out or solidify, the pump should be flushed after each use to prevent damage. In freezing temperatures the pump should be completely drained between uses.

Before pump operation, inspect all fasteners for loosening caused by gasket creep. Retighten loose fasteners to prevent leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material properties. Do not expose to UV light for extended periods of time.

In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping a product that is hazardous or toxic, the air exhaust must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure during operation. Make certain that all fasteners are in good condition and are reinstalled properly during reassembly.

Take action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping, valves, containers and other miscellaneous equipment must be properly grounded.

Safety Information

Grounding the Pump

WARNINGTake action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping, valves, containers or other miscellaneous equipment must be grounded.

UNIVERSAL ALL AODD

e8nmdlCsm-rev0912www.versamatic.com

Table of Contents

SECTION 1: PumP SPECIfICaTIONS ................1 •Nomenclature •Performance •Materials •DimensionalDrawings

SECTION 2: INSTallaTION & OPEraTION ......5 •PrincipleofPumpOperation •TypicalInstallationGuide •Troubleshooting

SECTION 3: ExPlOdEd VIEw ...........................8 •CompositeDrawings •PartsList •MaterialsCode

SECTION 4: warraNTy & CErTIfICaTES ....10 •Warranty •ECDeclarationofConformity-Machinery

Universal*

1: P

UMP

SPEC

S2:

INST

AL &

OP

3: E

XP V

IEW

4: W

ARRA

NTY

e8nmdlCsm-rev09121 • Model E8 Non-Metallic Bolted www.versamatic.com

Explanation of Pump Nomenclature

Model Pump Size Wetted Parts Non-Wetted Parts Diaphragm MaterialE Elima-Matic 6 1/4" A Aluminum A Aluminum 1 NeopreneUUltra-Matic 8 3/8" C Cast Iron S Stainless Steel 2NitrileVV-Series 5 1/2" S Stainless Steel PPolypropylene 3 (FKM)FluorocarbonRE AirVantage 7 3/4" H Alloy C G Groundable Acetal 4EPDM 1 1" PPolypropylene ZPTFE-coatedAluminum 5PTFE 41-1/4"or1-1/2" K Kynar JNickel-platedAluminum 6Santoprene(XL) 2 2" G Groundable Acetal C Cast Iron 7 Hytrel 3 3" B Aluminum (screen mount) QEpoxy-CoatedAluminum 9 Geolast

Diaphragm Series Valve Ball Material Valve Seat/Valve Seat O-Ring Material Construction DesignR Rugged 1Neoprene 1 Neoprene 9 BoltedDDome 2 Nitrile 2Nitrile 0 ClampedXThermo-Matic 3(FKM)Fluorocarbon 3(FKM)FluorocarbonTTef-Matic(2-piece) 4EPDM 4EPDMBVersa-Tuff(1-piece) 5PTFE 5PTFEFFUSION(one-piece 6Santoprene(XL) 6Santoprene(XL)integrated plate) 7 Hytrel 7 Hytrel 8 Polyurethane 8Polyurethane 9 Geolast 9 Geolast A Acetal AAluminumw/PTFEO-Rings S Stainless Steel SStainlessSteelw/PTFEO-Rings CCarbonSteelw/PTFEO-Rings HAlloyCw/PTFEO-Rings TPTFEEncapsulatedSiliconeO-Rings

Your Serial #: (fill in from pump nameplate) _____________________________________

VERSA-MATIC® MODEL IDENTIFICATION CODES

X X X X X X X X X X - X X X

Model

Pump Size

Wetted Parts

Non-Wetted Parts

Diaphragm Material

Diaphragm Series

Valve Ball Material

Valve Seat Material/Valve Seat O-ring Material

Construction Design

Revision Level

Options (if applicable)

Model Pump Size Wetted Parts Non-Wetted Parts Diaphragm MaterialE Elima-Matic 6 1/4" A Aluminum A Aluminum 1 Neoprene U Ultra-Matic 8 3/8" C Cast Iron S Stainless Steel 2 Buna-N V V-Series 5 1/2" S Stainless Steel P Polypropylene 3 (FKM) Fluorocarbon 7 3/4" H Hastelloy C G Groundable Acetal 4 Nordel 1 1" P Polypropylene Z PTFE-coated Aluminum 5 PTFE 4 1-1/4" or 1-1/2" K Kynar J Nickel-plated Aluminum 6 XL 2 2" G Groundable Acetal C Cast Iron 7 Hytrel 3 3" B Aluminum (screen mount) Q Epoxy-Coated Aluminum 9 Geolast

Diaphragm Series Valve Ball Material Valve Seat/Valve Seat O-ring Material Construction DesignR Rugged 1 Neoprene 1 Neoprene 9 Bolted D Dome 2 Buna-N 2 Buna-N 0 Clamped X Thermo-Matic 3 (FKM) Fluorocarbon 3 (FKM) Fluorocarbon T Tef-Matic (2-piece) 4 Nordel 4 Nordel B Versa-Tuff (1-piece) 5 PTFE 5 PTFE F FUSION (one-piece 6 XL 6 XL integrated plate) 7 Hytrel 7 Hytrel 8 Polyurethane 8 Polyurethane 9 Geolast 9 Geolast A Acetal A Aluminum w/ PTFE O-rings S Stainless Steel S Stainless Steel w/ PTFE O-rings C Carbon Steel w/ PTFE O-rings H Hastelloy C w/ PTFE O-rings T PTFE Encapsulated Silicone O-rings

Model #:

__ __ __ __ __ __ __ __ __ __ __ __ __(fill in from pump nameplate)

Your Model #:

UNIVERSAL TO ALL VM

1: P

UMP

SPEC

S

e8nmdlCsm-rev0912Model E8 Non-Metallic Bolted • 2www.versamatic.com

materials

Material Profile: Operating Temperatures:Max. Min.

Conductive Acetal: Tough, impact resistant, ductile. Good abrasionresistanceandlowfrictionsurface.Generallyinert,withgoodchemicalresistanceexceptforstrongacidsandoxidizingagents.

190°F88°C

-20°F-29°C

EPDM:Showsverygoodwaterandchemicalresistance.Haspoor resistance to oils and solvents, but is fair in ketones and alcohols.

280°F138°C

-40°F-40°C

FKM:(Fluorocarbon)Showsgoodresistancetoawiderange of oils and sovents; especially all aliphatic, aromatic and halogenated hydrocarbons, acids, animal and vegetable oils. Hotwaterorhotaqueoussolutions(over70°F)willattackFKM.

350°F177°C

-40°F-40°C

Hytrel®: Good on acids, bases, amines and glycols at room temperatures only.

220°F104°C

-20°F-29°C

Neoprene: All purpose. Resistance to vegetable oils. Generally not affected by moderate chemicals, fats, greases and many oilsandsolvents.Generallyattackedbystrongoxidizingacids,ketones, esters and nitro hydrocarbons and chlorinated aromatic hydrocarbons.

200°F93°C

-10°F-23°C

Nitrile: Generalpurpose,oil-resistant.Showsgoodsolvent,oil,waterandhydraulicfluidresistance.ShouldnotbeusedwithhighlypolarsolventslikeacetoneandMEK,ozone,chlorinatedhydrocarbons and nitro hydrocarbons.

190°F88°C

-10°F-23°C

Nylon: 6/6Highstrengthandtoughnessoverawide temperaturerange.Moderatetogoodresistancetofuels,oilsand chemicals.

180°F82°C

32°F0°C

Polypropylene:Athermoplasticpolymer.Moderatetensileandflexstrength.Resistsstongacidsandalkali.Attackedbychlorine,fumingnitricacidandotherstrongoxidizingagents.

180°F82°C

32°F0°C

PVDF:(PolyvinylideneFluoride)Adurablefluoroplasticwithexcellentchemicalresistance.ExcellentforUVapplications.High tensile strength and impact resistance.

250°F121°C

0°F-18°C

Santoprene®:Injectionmoldedthermoplasticelastomerwithnofabriclayer.Longmechanicalflexlife.Excellentabrasionresistance.

275°F135°C

-40°F-40°C

UHMW PE: A thermoplastic that is highly resistant to a broad rangeofchemicals.Exhibitsoutstandingabrasionandimpactresistance,alongwithenvironmentalstress-crackingresistance.

180°F82°C

-35°F-37°C

Urethane:Showsgoodresistancetoabrasives.Haspoorresistance to most solvents and oils.

150°F66°C

32°F0°C

Virgin PTFE:(PFA/TFE)Chemicallyinert,virtuallyimpervious.VeryfewchemicalsareknowntochemicallyreactwithPTFE;moltenalkalimetals,turbulentliquidorgaseousfluorineandafewfluoro-chemicalssuchaschlorinetrifluorideoroxygendifluoridewhichreadilyliberatefreefluorineatelevated temperatures.

220°F104°C

-35°F-37°C

Maximum and Minimum Temperatures are the limits for which these materials can be operated. Temperatures coupled with pressure affect the longevity of diaphragm pump components. Maximum life should not be expected at the extreme limits of the temperature ranges.

Metals:Alloy C:EqualtoASTM494CW-12M-1specificationfornickelandnickelalloy.Stainless Steel: EqualtoorexceedingASTMspecificationA743CF-8Mforcorrosionresistant iron chromium, iron chromium nickel and nickel based alloy castings for general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.

Forspecificapplications,alwaysconsulttheChemicalResistanceChart.

CAUTION! Operating temperature limitations are as follows:

Ambient temperature range -20Cto+40CProcess temperature range -20Cto+80Cformodelsratedascategory1equipment -20cto+100Cformodelratedascategory2equipmentInaddition,theambienttemperaturerangeandtheprocesstemperaturerangedonotexceedtheoperatingtemperaturerangeoftheappliednon-metallicpartsaslistedinthemanualsofthepumps.

afTErmarKET ParTS

Pumper PartsisyoursinglesourceforpartsthatfitAir-OperatedDoubleDiaphragm(AODD)pumps

• Wilden®

• ARO®

• Yamada®

RIGHT PART, RIGHT NOW

designed to perform equal to or greater than original equipment manufacture.

Phone:(419)[email protected]

Pumper Parts and its products are not affiliated with any of the original equipment manufacturers referenced herein. All original equipment manufacturers’ names, colors, pictures, descriptions and part numbers are used for identification purposes only. Pumper Parts® is a registered trade name of IDEX Corporation. All other trademarks, registered trademarks and product names are the property of their respective owners. Yamada® is a registered trademark of Yamada Corporation. ARO® is a registered trade name of Ingersoll-Rand Company. Wilden® is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company.

MODEL SPECIFIC UNIVERSAL ALL AODD

1: P

UMP

SPEC

S

e8nmdlCsm-rev09123 • Model E8 Non-Metallic Bolted www.versamatic.com

PerformanceE8 3/8" Bolted Metal

Flow Rate Adjustable to . . . . . . . . . 0-6.8gpm(25.7lpm)Port Size Suction . . . . . . . . . . . . . . . . . . 3/8"NPT(BSP) Discharge . . . . . . . . . . . . . . . . 3/8"NPT(BSP)Air Inlet . . . . . . . . . . . . . . . . . . . . . . . .1/4"NPTAir Exhaust . . . . . . . . . . . . . . . . . . . .1/4"NPTSuction Lift Dry . . . . . . . . . . . . . . . . . . . . . . . . . 8' (2.44 m)Max Solid Size(Diameter) . . . . . . . . . . . . . . . . . . . . . . . . 0.10" (2.25 mm)Max Noise Level . . . . . . . . . . . . . . . 78dB(A)Shipping Weights Polypropylene . . . . . . . . . . . . . 3 lbs (1.40 kg) Kynar . . . . . . . . . . . . . . . . . . .4.5 lbs. (2.04 kg)

NOTE: Performance based on the following: Elastomeric fitted pump, flooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.

Meters FeetDi

scha

rge H

ead

in P

SI1 53

0

100

90

80

70

60

50

40

30

20

10

0

240 220 200 180 160 140 120 100

80 60 40 20

0

75 70 65 60 55 50 45 40 35 30 25 20 15 10

5 0

64 98720

5 10 15 20 25 30 35Capacity in Liters Per Minute

Capacity in U.S. Gallons Per Minute

Displacement Per Stroke, 0.009 Gal. (0.034 L)

1

3

5

AIR CONSUMPTION IN SCFMAIR PRESSURE IN PSI

SCFM M3/HR 1 1.7 3 5.1 5 8.5

1: P

UMP

SPEC

S

e8nmdlCsm-rev0912Model E8 Non-Metallic Bolted • 4www.versamatic.com

E8 Non-Metallic Bolted Dimensionsininches(mm dimensions in brackets). The dimensions on this drawing are for reference only. A certified drawing can be requested if physical dimensions are needed.

dimensional drawings

2.79 [71]

0.94 [24]

Opposite Side: 1/4" Female NPT Air Exhaust

Removable Foot Pad 5/16" Mounting Hole

3/8" Female NPT Fluid Discharge Connection

3/8" Female NPT Fluid Suction Connection

1/4" Female NPT Air Inlet Connection

5.32 [135]

0.20 [5]

15.71 [399]

2.07 [53]

4.09 [104]

POLY 5.13 [130]

KYNAR 5.08 [129]

POLY 5.72 [145]

KYNAR5.67 [144]

2.07 [53]

Inches [mm]

2.79 [71]

0.94 [24]

Opposite Side: 1/4" Female NPT Air Exhaust

Removable Foot Pad 5/16" Mounting Hole

3/8" Female NPT Fluid Discharge Connection

3/8" Female NPT Fluid Suction Connection

1/4" Female NPT Air Inlet Connection

5.32 [135]

0.20 [5]

15.71 [399]

2.07 [53]

4.09 [104]

POLY 5.13 [130]

KYNAR 5.08 [129]

POLY 5.72 [145]

KYNAR5.67 [144]

2.07 [53]

Inches [mm]

Model Specific

1: P

UMP

SPEC

S

e8nmdlCsm-rev09125 • Model E8 Non-Metallic Bolted www.versamatic.com

Air Line

Discharged Fluid

DischargeStroke Suction

Stroke

PrimedFluid

Air-OperatedDoubleDiaphragm(AODD)pumpsarepoweredby compressed air, nitrogen or natural gas.

The main directional (air) control valve ① distributes compressedairtoanairchamber,exertinguniformpressureover the inner surface of the diaphragm ②. At the same time, theexhaustingair③ from behind the opposite diaphragm isdirectedthroughtheairvalveassembly(s)toanexhaust port ④.

As inner chamber pressure (P1)exceedsliquidchamberpressure (P2), the rod ⑤ connected diaphragms shift together creating discharge on one side and suction on the opposite side. The discharged and primed liquid’s directions arecontrolledbythecheckvalves(ballorflap)⑥ orientation.

The pump primes as a result of the suction stroke. The suctionstrokelowersthechamberpressure(P3) increasing the chamber volume. This results in a pressure differential necessary for atmospheric pressure (P4)topushthefluidthrough the suction piping and across the suction side check valveandintotheouterfluidchamber⑦.

Suction (side) stroking also initiates the reciprocating (shifting, stroking or cycling) action of the pump. The suction diaphragm’s movement is mechanically pulled through its stroke.Thediaphragm’sinnerplatemakescontactwithanactuator plunger aligned to shift the pilot signaling valve. Once actuated, the pilot valve sends a pressure signal to the opposite end of the main directional air valve, redirecting the compressed air to the opposite inner chamber.

Principle of Pump Operation

SAFE AIREXHAUSTDISPOSALAREA

PUMP INSTALLATION AREA

1" DIAMETER AIREXHAUST PIPING

1" DIAMETER AIREXHAUST PIPING

1" DIAMETER AIREXHAUST PIPING

MUFFLER

LIQUIDLEVEL

SUCTIONLINE

LIQUIDLEVEL

SUCTIONLINE

MUFFLER

MUFFLER

SUBMERGED ILLUSTRATION

Pumpcanbesubmergedifthepumpmaterialsofconstructionarecompatiblewiththeliquidbeingpumped.Theairexhaustmust be piped above the liquid level. When the pumped product sourceisatahigherlevelthanthepump(floodedsuctioncondition),pipetheexhausthigherthantheproductsourcetoprevent siphoning spills.

MODEL SPECIFIC

2: IN

STAL

& O

P

e8nmdlCsm-rev0912Model E8 Non-Metallic Bolted • 6www.versamatic.com

Installation And Start-Up Locatethepumpasclosetotheproductbeingpumpedaspossible.Keepthesuctionlinelengthandnumberoffittingstoaminimum.Donotreducethesuctionlinediameter.

Air Supply Connectthepumpairinlettoanairsupplywithsufficientcapacityandpressuretoachievedesiredperformance.Apressureregulatingvalveshouldbeinstalledtoinsureairsupplypressuredoesnotexceedrecommendedlimits.

Air Valve Lubrication The air distribution system is designed to operate WITHOUT lubrication. This is the standard mode of operation. If lubrication is desired, install an air line lubricator settodeliveronedropofSAE10non-detergentoilforevery20SCFM(9.4liters/sec.)ofairthepumpconsumes.ConsultthePerformanceCurvetodetermineairconsumption.

Air Line Moisture Waterinthecompressedairsupplymaycauseicingorfreezingoftheexhaustair,causingthepumptocycleerraticallyorstopoperating.Waterintheairsupplycanbereducedbyusingapoint-of-useairdryer.

Air Inlet And Priming Tostartthepump,slightlyopentheairshut-offvalve.Afterthepumpprimes,theairvalvecanbeopenedtoincreaseairflowasdesired.Ifopeningthevalveincreasescyclingrate,butdoesnotincreasetherateofflow,cavitationhasoccurred.Thevalveshouldbeclosedslightlytoobtainthemostefficientairflowtopumpflowratio.

Surge Suppressor

Shut-Off Valve

Pressure Gauge

Drain PortShut-OffValve

CheckValve

Air Inlet

Discharge

Unregulated AirSupply to Surge

Suppressor

Pipe Connection(Style Optional)

Flexible Connector

Flexible Connector

VacuumGauge

Suction

Shut-Off Valve

Drain Port Pipe Connection(Style Optional)

FlexibleConnector

Air Dryer

Filter Regulator

Note: Pipe weight should not be supported by pump connections.

Muffler(Optional Piped Exhaust)

recommended Installation Guide

Available Accessories: 1.SurgeSuppressor 2. Filter/Regulator 3. AirDryer

1

2

3

Note: Surge Suppressor and Pipingmustbesupportedaftertheflexibleconnection.

CAUTIONThe air exhaust should be piped to an area for safe disposition of the product being pumped, in the event of a diaphragm failure.

Principle of Pump Operation

SUBMERGED ILLUSTRATION

UNIVERSAL ALL AODD

2: IN

STAL

& O

P

e8nmdlCsm-rev09127 • Model E8 Non-Metallic Bolted www.versamatic.com

Troubleshooting GuideSymptom: Potential Cause(s): Recommendation(s):Pump Cycles Once Deadhead(systempressuremeetsorexceedsair

supply pressure).Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).

Air valve or intermediate gaskets installed incorrectly. Installgasketswithholesproperlyaligned.Bent or missing actuator plunger. Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate / Cycle

Pumpisoverlubricated. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Lackofair(linesize,PSI,CFM). Checktheairlinesizeandlength,compressorcapacity(HPvs.cfmrequired).Check air distribution system. Disassembleandinspectmainairdistributionvalve,pilotvalveandpilotvalveactuators.Dischargelineisblockedorcloggedmanifolds. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.Deadhead(systempressuremeetsorexceedsairsupply pressure).

Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).

Blockedairexhaustmuffler. Removemufflerscreen,cleanorde-ice,andre-install.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Pumpchamberisblocked. Disassembleandinspectwettedchambers.Removeorflushanyobstructions.

Pump Cycles and Will Not Prime or No Flow

Cavitation on suction side. Check suction condition (move pump closer to product).Check valve obstructed. Valve ball(s) not seating properly or sticking.

Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket. Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or manifold).

Wornvalveballorvalveseat.Wornfingersinvalveballcage(replacepart).CheckChemical Resistance Guide for compatibility.

Valve ball(s)/seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.

Pump Cycles Running Sluggish/Stalling, Flow Unsatisfactory

Over lubrication. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Icing. Removemufflerscreen,de-ice,andre-install.Installapointofuseairdrier.Clogged manifolds. CleanmanifoldstoallowproperairflowDeadhead(systempressuremeetsorexceedsairsupply pressure).

Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).

Cavitation on suction side. Check suction (move pump closer to product).Lackofair(linesize,PSI,CFM). Checktheairlinesize,length,compressorcapacity.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Airsupplypressureorvolumeexceedssystemhd. Decreaseinletair(press.andvol.)tothepump.Pumpiscavitatingthefluidbyfastcycling.Undersizedsuctionline. Meetorexceedpumpconnections.Restrictiveorundersizedairline. Install a larger air line and connection. Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.Purgingthechambersofaircanbedangerous.

Product Leaking Through Exhaust

Diaphragmfailure,ordiaphragmplatesloose. Replace diaphragms, check for damage and ensure diaphragm plates are tight.Diaphragmstretchedaroundcenterholeorboltholes. Checkforexcessiveinletpressureorairpressure.ConsultChemicalResistanceChartforcompatibility

withproducts,cleaners,temperaturelimitationsandlubrication.Premature Diaphragm Failure

Cavitation. Enlargepipediameteronsuctionsideofpump.Excessivefloodedsuctionpressure. Movepumpclosertoproduct.Raisepump/placepumpontopoftanktoreduceinletpressure.

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.Misapplication(chemical/physicalincompatibility). ConsultChemicalResistanceChartforcompatibilitywithproducts,cleaners,temperaturelimitations

and lubrication.Incorrectdiaphragmplatesorplatesonbackwards,installedincorrectlyorworn.

CheckOperatingManualtocheckforcorrectpartandinstallation.Ensureouterplateshavenotbeenworntoasharpedge.

Unbalanced Cycling Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Undersizedsuctionline. Meetorexceedpumpconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

UNIVERSAL ALL AODD, EXCEPT FLAP

2: IN

STAL

& O

P

e8nmdlCsm-rev0912Model E8 Non-Metallic Bolted • 8www.versamatic.com

Troubleshooting GuideSymptom: Potential Cause(s): Recommendation(s):Pump Cycles Once Deadhead(systempressuremeetsorexceedsair

supply pressure).Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).

Air valve or intermediate gaskets installed incorrectly. Installgasketswithholesproperlyaligned.Bent or missing actuator plunger. Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate / Cycle

Pumpisoverlubricated. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Lackofair(linesize,PSI,CFM). Checktheairlinesizeandlength,compressorcapacity(HPvs.cfmrequired).Check air distribution system. Disassembleandinspectmainairdistributionvalve,pilotvalveandpilotvalveactuators.Dischargelineisblockedorcloggedmanifolds. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.Deadhead(systempressuremeetsorexceedsairsupply pressure).

Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).

Blockedairexhaustmuffler. Removemufflerscreen,cleanorde-ice,andre-install.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Pumpchamberisblocked. Disassembleandinspectwettedchambers.Removeorflushanyobstructions.

Pump Cycles and Will Not Prime or No Flow

Cavitation on suction side. Check suction condition (move pump closer to product).Check valve obstructed. Valve ball(s) not seating properly or sticking.

Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket. Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or manifold).

Wornvalveballorvalveseat.Wornfingersinvalveballcage(replacepart).CheckChemical Resistance Guide for compatibility.

Valve ball(s)/seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.

Pump Cycles Running Sluggish/Stalling, Flow Unsatisfactory

Over lubrication. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Icing. Removemufflerscreen,de-ice,andre-install.Installapointofuseairdrier.Clogged manifolds. CleanmanifoldstoallowproperairflowDeadhead(systempressuremeetsorexceedsairsupply pressure).

Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).

Cavitation on suction side. Check suction (move pump closer to product).Lackofair(linesize,PSI,CFM). Checktheairlinesize,length,compressorcapacity.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Airsupplypressureorvolumeexceedssystemhd. Decreaseinletair(press.andvol.)tothepump.Pumpiscavitatingthefluidbyfastcycling.Undersizedsuctionline. Meetorexceedpumpconnections.Restrictiveorundersizedairline. Install a larger air line and connection. Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.Purgingthechambersofaircanbedangerous.

Product Leaking Through Exhaust

Diaphragmfailure,ordiaphragmplatesloose. Replace diaphragms, check for damage and ensure diaphragm plates are tight.Diaphragmstretchedaroundcenterholeorboltholes. Checkforexcessiveinletpressureorairpressure.ConsultChemicalResistanceChartforcompatibility

withproducts,cleaners,temperaturelimitationsandlubrication.Premature Diaphragm Failure

Cavitation. Enlargepipediameteronsuctionsideofpump.Excessivefloodedsuctionpressure. Movepumpclosertoproduct.Raisepump/placepumpontopoftanktoreduceinletpressure.

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.Misapplication(chemical/physicalincompatibility). ConsultChemicalResistanceChartforcompatibilitywithproducts,cleaners,temperaturelimitations

and lubrication.Incorrectdiaphragmplatesorplatesonbackwards,installedincorrectlyorworn.

CheckOperatingManualtocheckforcorrectpartandinstallation.Ensureouterplateshavenotbeenworntoasharpedge.

Unbalanced Cycling Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Undersizedsuctionline. Meetorexceedpumpconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.

Composite repair Parts drawing

repair and maintenance Kits

DETAIL B

DETAIL B

DETAIL A

45

46 44

38

40 37 3433

1210

9

62

1

11

2 35

4

35

8

60 in-lbs(6.8 N-m)

TorqueSettings

25 in-lbs(2.8 N-m)

40 in-lbs(4.5 N-m)

25 2218 19 20 21

60 50 5253 5151

Wetted End KitsPart Number DescriptionE8PXLKIT XLElastomerKitE8GKIT GeolastElastomerKitE8PTXKIT PTFEElastomerKit

Air End Kit - Part #: E8 Air KitDescription Qty Part NumberValveSpoolU-Cup 2 P98-104AEndCapO-Ring 2 E500EAirDiverter 1 10-075ValveInsert 1 E500HValveGasket 1 E800JPilotShaftO-Ring 6 E503BMainShaftO-Ring 2 E503B

Detail A

Torque Settings

Detail B

WaterChamberBolts 40in-lbs(4.5N-m)DiaphragmPlates—Rubber 60in-lbs(6.8N-m)DiaphragmPlates—PTFE 60in-lbs(6.8N-m)AirValveCapScrews 25in-lbs(2.8N-m)

General Model Specific

3: E

XP V

IEW

e8nmdlCsm-rev09129 • Model E8 Non-Metallic Bolted www.versamatic.com

Composite repair Parts listAir Valve Assembly

Item Qty. Description Part Number1 AirValveAssembly(Includesitems1-10) E800

1 1 Valve Body 10-0482 1 Valve Spool E500BASY(Includes(2)P98-104A)3 2 ValveSpoolU-Cup P98-104A4 2 EndCap E800D(Includes(1)E800DASY)5 2 EndCapO-Ring E500E8 1 AirDiverter 10-0759 1 Valve Insert E500H

10 1 Valve Gasket E800J11 4 ValveScrew 10-050

Air End AssemblyItem Qty. Description Part Number12 1 CenterSection E801A18 1 PilotShaft E803A19 5 PilotShaftSpacer E503C20 6 PilotShaftO-Ring E503B21 2 PilotShaftSnapRing E503D22 2 ShaftRetainer E801B25 4 ShaftRetainerScrew E501C33 1 Muffler 06-034

Diaphragm Assembly

Item Qty. Description Part NumberTPE PTFE

34 2 MainShaftO-Ring E503B E503B35 1 MainShaft 10-028 10-02837 2 InnerDiaphragmPlate C126 C12638 2 OuterDiaphragmPlate 10-023(Poly),10-040(Kynar) 10-023(Poly),10-040(Kynar)40 2 Diaphragm 10-032(XL),10-033(Geolast) 10-044(PTFE)

Wet End Assembly

Item Qty. Description Part NumberStandard: Polypropylene Option 1: Kynar

44 2 WaterChamber 10-002 10-03645 4 WaterChamberBolt(Long) 10-052 10-05246 12 WaterChamberBolt(Short) 10-051 10-05150 4 ValveSeat 10-022(Poly) 10-039(Kynar)51 8 ValveSeatSeal 10-073(XL),10-045(PTFE) 10-073(XL),10-045(PTFE)52 4 ValveStem 10-005 10-03853 4 Spring 10-030 10-03060 2 Manifold 10-003 10-03762 4 FootPad 10-035 10-035

MODEL SPECIFIC

3: E

XP V

IEW

e8nmdlCsm-rev0912www.versamatic.com Model E8 Non-Metallic Bolted • 10

written warranty5 - yEar limited Product warranty

Quality System ISO9001 Certified • Environmental Management Systems ISO14001 Certified Versa-Matic warrants to the original end-use purchaser that no product sold by

Versa-Matic that bears a Versa-Matic brand shall fail under normal use and service due to a defect in materialor workmanship within five years from the date of shipment from Versa-Matic’s factory.

~ See complete warranty at http://www.versamatic.com/pdfs/VM%20Product%20Warranty.pdf ~

DATE: August 10, 2011FECHA: DATUM:DATA:DATO:PÄIVÄYS:

AUTHORIZED / APPROVED BY: Approuve par: Aprobado por: Genehmigt von: approvato da: Goedgekeurd door: Underskrift: Valtuutettuna: Bemyndiget av: Autorizado Por:

04/19/2012 REV 07 VMQR 044FM

This product complies with the following European Community Directives: Ce produit est conforme aux directives de la Communauté européenne suivantes: Este producto cumple con las siguientes Directrices de la Comunidad Europea: Dieses produkt erfüllt die folgenden Vorschriften der Europäischen Gemeinschaft: Questo prodotto è conforme alle seguenti direttive CEE: Dir produkt voldoet aan de volgende EG-richtlijnen: Denna produkt överensstämmer med följande EU direktiv: Versa-Matic, Inc., erklærer herved som fabrikant, at ovennævnte produkt er i overensstemmelse med bestemmelserne i Direkktive:Tämä tuote täyttää seuraavien EC Direktiivien vaatimukstet:Dette produkt oppfyller kravene til følgende EC Direktiver:Este produto está de acordo com as seguintes Directivas comunitárias:

MANUFACTURED BY:FABRIQUE PAR:FABRICADA POR:HERGESTELLT VON:FABBRICATO DA:VERVAARDIGD DOOR:TILLVERKAD AV:FABRIKANT:VALMISTAJA:PRODUSENT:FABRICANTE:

DECLARATION DE CONFORMITE • DECLARACION DE CONFORMIDAD • ERKLÄRUNG BEZÜGLICH EINHALTUNG DER VORSCHRIFTENDICHIARAZIONE DI CONFORMITÀ • CONFORMITEITSVERKLARING • DEKLARATION OM ÖVERENSSTÄMMELSE

EF-OVERENSSTEMMELSESERKLÆRING • VAATIMUSTENMUKAISUUSVAKUUTUS • SAMSVARSERKLÄRING DECLARAÇAO DE CONFORMIDADE

VERSA-MATIC®

Warren Rupp, Inc.A Unit of IDEX Corporation 800 North Main Street P.O. Box 1568 Mansfield, OH 44901-1568 USA

Tel: 419-526-7296Fax: 419-526-7289

This product has used the following harmonized standards to verify conformance: EN809:1998+A1:2009Ce materiel est fabriqué selon les normes harmonisées suivantes, afin d’ en garantir la conformité:

Este producto cumple con las siquientes directrices de la comunidad europa:Dieses produkt ist nach folgenden harmonisierten standards gefertigtworden, die übereinstimmung wird bestätigt:Questo prodotto ha utilizzato i seguenti standards per verificare la conformita´:De volgende geharmoniseerde normen werden gehanteerd om de conformiteit van dit produkt te garanderen: För denna produkt har följande harmoniserande standarder använts för att bekräfta överensstämmelse:Harmoniserede standarder, der er benyttet:Tässä tuotteessa on sovellettu seuraavia yhdenmukaistettuja standardeja:Dette produkt er produsert i overenstemmelse med fløgende harmoniserte standarder:Este produto utilizou os seguintes padrões harmonizados para varificar conformidade:

PUMP MODEL SERIES: E SERIES, V SERIES, VT SERIES, VSMA3, SPA15, RE SERIES AND U2 SERIES

Dave RoseberryEngineering Manager

DECLARATION OF CONFORMITY

2006/42/ECon Machinery, according

to Annex VIII

MODEL SPECIFIC

Repair Kit

vs.

Partial Repair

=

• Reduces frequency of repairs• Reduces downtime• Reduces cost• Increase your uptime • Improve parts availability• Extended service life

Ordering Parts Kits Over Individual Components:

Example Data:Repair = 1 hour • Pump model #: E2AA2D220-OE • Buna wet-end repairLabor rate fully burdened at $125/hour • Lost product assumes paint

COST OF WET END REPAIR Partial Repair

(1 Diaphragm)Complete Repair

KitParts $56 $148

Labor $125 $125

Lost Product $200 $200

Down-Time $1,000 $1,000

Annual Frequency of Repair 2 1Estimated Cost Per Repair:

$1,381 $1,473

Estimated Annual Cost:

$2,772 $1,473

EstimatedAnnual Savings:* $0 $1,299

www.versamatic.com

Kit: AnnualSavings

$1,299

Genuine Parts, Real Value


Recommended