H07VVH6-FPVC flat cables
2.1 - 1
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
H07VVH6-FPVC flat cables
Design
MarkingH07VVH6-F or 07VVH6-F Number of cores - Cross-sectionNEXANS year - week
Applications
StandardsHD 359 S2 IEC 60227 part 6
450/750 VPower and control flat cables canbe used on festoon systems onhandling equipments e.g.overhead cranes.Specially designed for indoorand outdoor applications.
in accordance with HD 308 S24 cores: black - grey - green/yellow -brown5 cores: black - brown - green/yellow - blue - grey> 5 cores: black with white printed numbers+ green/yellow
1. ConductorFlexible plain copper class 5IEC 60228
2. InsulationPVC, threads are placed ineach group of cores to stripthe outer sheath.
3. Outer sheathPVCColour: black
1
2
3
1
2
3
Festoon Cables
Nominal voltage Uo/U 450/750 VMaximum operating voltage in AC systems Um 750 V
Test voltage 2.5 kV - 50 Hz in ACCurrent rating (A) see electrical characteristics page 3.2 B
Max. temperature at the conductor :- in service + 70 °C- in short circuit + 150 °C
Max. surface temperature :- fixed installation - 35 °C up to + 60 °C- mobile operation - 25 °C up to + 60 °C
Electrical and Thermal properties
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii construction characteristics see page 3.1 ETests Bending testTravelling Festoon speed up to 120 m/min
H07VVH6-F
Chemical properties
Oil, acid and alcaline resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60 332 part 1.
Mechanical properties
Cable characteristics
Flexible Oil resistantGoodGood -25 + 60 °C
PbLead free compound
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
4 G 4* 21 x 6.5 3004 G 6* 23 x 7 3904 G 10* 29 x 9 6204 G 16* 37 x 11 9904 G 25* 46 x 13.5 1,5504 G 35* 51 x 14.8 2,0304 G 50* 56 x 16.5 2,6504 G 70* 63 x 18 3,6504 G 95* 73 x 20.5 4,5505 G 4* 25 x 6.5 3805 G 6* 28 x 7 4805 G 10* 35 x 9 7805 G 16* 43 x 11 1,2007 G 4* 37 x 6.5 5507 G 6* 41 x 7 700
4 G 1.5* 15 x 5 1504 G 2.5* 18.5 x 6 2105 G 1.5* 18 x 5 1805 G 2.5* 22 x 6 2607 G 1.5* 26 x 5 2607 G 2.5* 32 x 6 3808 G 1.5* 29 x 5 3008 G 2.5* 35 x 6 405
10 G 1.5* 35 x 5 36012 G 1.5* 40.5 x 5 42012 G 2.5* 50.5 x 6 62012 G 4 57 x 6.5 88014 G 1.5* 48 x 5 49016 G 1.5* 54 x 5 56018 G 1.5* 58 x 5 620
Weightapprox.
(kg/km)
Number of cores and nominalcross-section
(mm2)
H07VVH6-F
Outer dimensionsapprox.
(mm)
POWER
CONTROL
*Stocked products
Options• Cables without earth core (green/yellow) on request• Remark: <HAR> CENELEC types are only up to 25 mm2
LSHFHalogen free flat cables
2.1 - 5
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
LSHFHalogen free flat cables
Design
Marking
3. Outer sheathPolyolefinHalogen Free CompoundColour: black
LSHF Number of cores - cross-section0.6/1 kV - NEXANS year - week
Applications
StandardsNexans specification
0.6/1 (1.2) kVPower and control flat cablesare used on festoon systems onhandling equipments. Special design where halogenfree and low smoke materialare required. (e.g. nuclear plants)
1. ConductorFlexible plain copper class 5IEC 60228
2. InsulationHalogen Free Compound
1
2
3
In accordance with HD 308 S24 cores: black - grey - green/yellow -brown5 cores: black - grey - green/yellow -brown - blue> 5 cores: black with white printed numbers - green/yellow
Festoon Cables
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
LSHF Halogen Free Flat Cables
Chemical properties
Electrical and Thermal properties
For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame and fire-retardant according to IEC 60332-1 and IEC 60332-3
Cable characteristics
BrClFl
Flexible Low toxicityIEC 60754
Low smokeIEC 61034
Good Low corrosivityIEC 60754
Flame and FireRetardant
-25 + 60 °C
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii see construction characteristics page 3.1 ETests Bending testTravelling Festoon speed up to 120 m/min
Mechanical properties
Halogen freecompound
Nominal voltage Uo/U 0.6/1 kVMaximum operating voltage in AC systems Um 1.2 kV
Test voltage 3.5 kV - 50 Hz in ACCurrent rating (A) see electrical characteristics page 3.2 B
Max. temperature at the conductor:- in service + 90 °C- in short circuit + 250 °C
Max. surface temperature:- fixed installation - 40 °C up to + 60 °C- mobile operation - 25 °C up to + 60 °C
4 G 1.5 16 x 5 110
4 G 2.5 19 x 5.7 170
4 G 4 21 x 6.5 250
4 G 6 23.5 x 7 330
4 G 10 29 x 9 550
4 G 16 35 x 10.4 800
4 G 25 45.5 x 13.5 1,350
4 G 35 50.5 x 14.8 1,800
4 G 50 56 x 16.5 2,400
4 G 70 63 x 18 3,250
8 G 1.5 29 x 5 220
8 G 2.5 35 x 5 330
12 G 1.5 41 x 5 320
12 G 2.5 51 x 5.7 490
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cables (mm2) Overall
dimensions(mm)
Number of cores and nominal cross-section
(mm2)
Outer dimensionsapprox.
(mm)
Weightapprox.
(kg/km)
LSHF Halogen Free Flat Cables
POWER
CONTROL
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
RHEYCORD®-OFE MFlexible cables with optical fiber elements (OFE)
2.1 - 9
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Fibers identification
RHEYCORD®-OFE M Flexible cables with optical fiber elements (OFE)
Design
Markinge.g.:RHEYCORD-OFE M24 G 62.5/125 I NEXANS Iyear
Applications
StandardsDIN EN 188000
UL File ZMHX.E305416
For data transmission withoutelectromagnetic smog.Used in festoon and e-chainsystems on cranes and othermaterial handling equipments.
DIN EN 188000
3. Outer sheathChlorinated rubber compound5GM5 according to DIN VDE 0207 part 21Colour: orange
1. Optical fibersFiber types: E9/125 μmG50/125 μm G62.5/125 μmFibers layed in gel filled highperformance thermoplastic loosetube
2. Strain reliefHigh-end synthetic rovings
1
2
3
Festoon Cables
Torsional stress ≤ 120 °/mPermissible bending radii- fixed installation ≥ 50 mm- free movement ≥ 100 mm- deflection pulleys ≥ 200 mmTests alternating/reversed bending test, roller bending test,
torsional resistance testTravelling speed (festoon, e-chain) up to 240 m/min (for higher speed contact us)
EMC Excellent EMC compatibility due to 6 core design and reduced production tolerances acc. to DIN VDE 250 part 1 .
Maximum surface temperature:- fixed installation -40 °C up to +80 °C- mobile operation -30 °C up to +60 °C
Optical properties see general characteristics page 3.3 B
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
RHEYCORD®-OFE M
Chemical properties
Optical and Thermal properties
Oil resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60332 part 1.
Mechanical properties
Cable characteristics
Flexible Oil resistantGood -30 + 60 °C
6 G 50/12512 G 50/125*18 G 50/12524 G 50/125
6 G 62.5/12512 G 62.5/125*18 G 62.5/12524 G 62.5/125
6 E 9/12512 E 9/125*18 E 9/12524 E 9/125
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Min.(mm)
Max.tensile load.
(N)
Types
RHEYCORD®-OFE M
Max.(mm)
Outer diameter
MULTI-MODE/GRADED INDEX
MONO-MODE/SINGLE MODE
*Stocked products
Options• Pre-assembled with plugs
Weightapprox.
(kg/km)
9 11 100 800
RHEYFESTOON®(C) (N)3GRDGC5GFlexible screened round festoon cables
2.1 - 8
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
RHEYFESTOON®(C) (N)3GRDGC5G Flexible screened round festoon cables
Design
Markinge.g.:RHEYFESTOON(C) (N)3GRDGC5G-J3x50+3x25/3 0.6/1 kV I NEXANS I year VDE Reg. No. 7891
Applications
StandardsIn line with DIN VDE 0250part 812 with VDE Reg. No. 7891
0.6/1 (1.2) kVHeavy duty rubber cable forpower supply. For festoonapplications with mechanicaltensile stress combinated withdynamic stress.Especially developed to preventelectrical and electromagneticdisturbances and to protectparallel laying control cablesagainst interferences.
DIN VDE 0293 part 308/ HD 308 S26 cores design:- three phase cores:
brown - black - grey- three protection cores:
green/yellow in the interstices
4. EMC - ScreenComposite screen of tinnedcopper wires and syntheticthreads. Coverage >80 %
5. Outer sheathChlorinated rubber compound5GM5 acc. to DIN VDE 0207 part 21Colour: black
1. ConductorFlexible stranded, plain copperacc. to DIN EN / IEC 60228 class 5
2. InsulationElastomeric rubber compoundRHEYCLEAN-HEPRbetter than IEC 60502-1
3. Inner sheathSpecial synthetic rubbercompound better than GM1b,acc. to DIN VDE 0207 part 21
1
2
3
4
5
Festoon Cables
EMC Excellent EMC compatibility due to 6 core design and reduced production tolerances acc. to DIN VDE 250 part 1 .
Nominal voltage Uo/U 0.6/ 1 kVMaximum operating voltage in AC systems Um 1.2 kV Maximum operating voltage in DC systems Vm 1.8 kV
Test voltage:- Power 3.0 kV in AC- Control 2.0 kV in AC
Current rating (A) according to DIN VDE 0298-4, see electrical characteristics page 3.2 B
Maximum temperature at the conductor:- in service +90 °C- under short-circuit conditions +250 °C
Maximum surface temperature:- fixed installation -50 °C up to +80 °C- mobile operation -35 °C up to + 80 °C
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii according to DIN VDE 0298-3, see construction characteristics page 3.1 E
Tests Bending testFestoon speed up to 240 m/min (higher speed upon request)
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
RHEYFESTOON®(C) (N)3GRDGC5G
Chemical properties
Electrical and Thermal properties
Oil resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60332 part 1.
Mechanical properties
Cable characteristics
Flexible Oil resistantGoodGoodExcellent -35 + 80 °CEMI
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
4x4 18 20 600 2404x6 19 21 780 3604x10 20 22 1,050 6005x1.5 13 16 330 1135x2.5 14 16 390 1903x16 + 3x16/3 22 25 1,200 9603x25 + 3x16/3 26 29 1,600 1,5003x35 + 3x16/3* 29 32 2,000 2,1003x50 + 3x25/3* 33 36 2,500 3,000
Min.(mm)
Weightapprox.
(kg/km)
RHEYFESTOON®(C) (N)3GRDGC5G
Max.(mm)
Max.tensile load.
(N)
*Stocked products
Options• Further numbers of cores and cross-section upon request
Outer diameterNumber of cores andnominal cross-section
(mm2)
RHEYFESTOON® (N)3GRD5GFlexible round festoon cables
2.1 - 7
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
RHEYFESTOON® (N)3GRD5G Flexible round festoon cables
Design
Markinge.g.: RHEYFESTOON (N)3GRD5G12 G 1.5 0.6/1 kV I NEXANS Iyear VDE Reg. No. 7891
Applications
StandardsIn line with DIN VDE 0250part 812 with VDE Reg. No. 7891
0.6/1 (1.2) kVHeavy duty rubber cable forcontrol and power supplies.For festoon applications withmechanical tensile stresscombinated with dynamicstress.
3. Inner sheathSpecial synthetic rubbercompound better than GM1bacc. to DIN VDE 0207 part 21
4. Outer sheathChlorinated rubber compound5GM5 acc. to DIN VDE 0207 part 21Colour: black
1. ConductorFlexible stranded plain copper, acc. to DIN EN / IEC 60228 class 5
2. InsulationElastomeric rubber compoundRHEYCLEAN-HEPRbetter than IEC 60502-1
DIN VDE 0293 part 308/ HD 308 S24 cores: green/yellow - brown - black -grey5 cores: green/yellow - blue - brown -black - grey≥ 5 cores: black with white printed numbers -green/yellow (in the outer layer)6 cores design: brown - black - grey - 3 green/yellow (in the interstices)
1
2
3
4
Festoon Cables
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii according to DIN VDE 0298-3, see construction characteristics page 3.1 E
Tests alternating/reversed bending test, roller bending test,torsional resistance test
Festoon speed up to 240 m/min, higher speed upon request
EMC Excellent EMC compatibility due to 6 core design and reduced production tolerances acc. to DIN VDE 250 part 1 .
Nominal voltage Uo/U 0.6/ 1 kVMaximum operating voltage in AC systems Um 1.2 kV Maximum operating voltage in DC systems Vm 1.8 kV
Test voltage:- Power 3.0 kV in AC- Control 2.0 kV in AC
Current rating (A) according to DIN VDE 0298-4, see electrical characteristics page 3.2 B
Maximum temperature at the conductor:- in service +90 °C- under short-circuit conditions +250 °C
Maximum surface temperature:- fixed installation -50 °C up to +80 °C- mobile operation -35 °C up to +80 °C
RHEYFESTOON® (N)3GRD5G
Chemical properties
Electrical and Thermal properties
Oil resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60332 part 1.
Mechanical properties
Cable characteristics
Flexible Oil resistantGoodExcellent -35 + 80 °C
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
1 x 35* 12 14 400 5251 x 50* 15 17 600 7501 x 70* 16 18 800 1,0501 x 95* 18 20 1,000 1,4251 x 120* 20 22 1,300 1,8001 x 150 23 25 1,700 2,2501 x 185 25 27 2,000 2,7754 x 4* 14 16 350 2404 x 6* 16 18 500 3604 x 10* 19 21 700 6004 x 16* 22 25 1,100 9604 x 25* 26 29 1,600 1,5004 x 35* 29 32 2,100 2,1004 x 50* 35 38 3,000 3,0003 x 35 + 3 x 16/3 27 30 1,750 1,5753 x 50 + 3 x 25/3 31 33 2,500 2,2503 x 70 + 3 x 35/3 36 39 3,600 3,1503 x 95 + 3 x 50/3 41 44 4,500 4,2755 x 4* 16 19 500 3005 x 6* 17 20 600 4505 x 10* 20 23 900 7505 x 16* 24 27 1,350 1,2005 x 25* 29 33 2,000 1,900
12 x 1.5 15 17 450 27018 x 1.5 17 19 650 40524 x 1.5* 21 23 850 54030 x 1.5 22 24 950 67536 x 1.5 23 26 1,100 81012 x 2.5* 17 20 600 45018 x 2.5* 20 23 900 65024 x 2.5* 23 26 1,150 90030 x 2.5* 26 29 1,350 1,12536 x 2.5 28 31 1,600 1,350
6 x (2 x 0.5) C* 20 22 780 1806 x (2 x 1) C* 24 27 810 1809 x (2 x 0.5) C* 26 29 990 2709 x (2 x 1) C* 33 36 1,080 27012 x 1 (C) 16 18 590 180
Min.(mm)
Weightapprox.
(kg/km)
Number of coresand nominalcross-section
(mm2)Max.(mm)
Max.tensile load
(N)
Outer diameter
POWER
CONTROL
BUS
RHEYFESTOON® (N)3GRD5G
*Stocked products
Options• Further numbers of cores and cross-section upon request
RHEYFLAT®-N (N)GFLCGOEU-JScreened rubber flat festoon cables
2.1 - 4
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
RHEYFLAT®-N (N)GFLCGOEU-J Screened rubber flat festoon cables
Design
Markinge.g.:RHEYFLAT-N (N)GFLCGOEU-J12 G 1.5 I NEXANS I
Applications
StandardsIn line withDIN VDE 0250 part 809
300/500 VUsed for festoon and handlingsystems, machine tools, lifts ande-chain cable carrier systems.For applications with highmechanical stress and frequentbending in one plane only.Copper screens are efficientagainst electro magneticdisturbances caused by powercables.
3. ScreenTinned copper braid,coverage >80 %
4. Outer sheathChlorinated rubbercompound 5GM3 acc. to DIN VDE 0207 part 21Colour: black
1. ConductorFlexible stranded plain copper,≤ 25 mm2:extra flexible stranded,class 6 ≥ 35 mm2: flexible stranded, class 5according to DIN EN / IEC 60228
2. InsulationElastomeric EPR, rubbercompound 3GI3 acc. to DIN VDE 0207 part 20
DIN VDE 0293-308 / HD 308 S24 cores: brown - green/yellow - grey - black5 cores:blue - brown - green/yellow - black -grey≥ 5 cores: black with white white no .-green/yellow - black
1
2
3
4
Festoon Cables
EMC Excellent EMC compatibility due to 6 core design and reduced production tolerances acc. to DIN VDE 250 part 1 .
Nominal voltage Uo/U 300/500 VMaximum operating voltage in AC systems Um 500 V Maximum operating voltage in DC systems Vm 750 V
Test voltage (according to DIN VDE 0250 part 809) 2.0 kV in ACCurrent rating (A) according to DIN VDE 0298-4,
see electrical characteristics page 3.2 B
Maximum temperature at the conductor:- in service +90 °C- under short-circuit conditions +250 °C
Maximum surface temperature:- fixed installation -50 °C up to +80 °C- mobile operation -35 °C up to +80 °C
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii according to DIN VDE 0298-3, see construction characteristics page 3.1 E
Tests Bending testFestoon speed up to 180 m/min
RHEYFLAT®-N (N)GFLCGOEU-J
Chemical properties
Electrical and Thermal properties
Oil resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60332 part 1.
Mechanical properties
Cable characteristics
Flexible Oil resistantGoodGoodGood -35 + 80 °CEMI
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
4 x 1.5 C* 18.5 x 6.5 220 8 x 1.5 C* 36 x 7.5 470
12 x 1.5 C* 54.5 x 8.5 7454 x 2.5 C* 22.5 x 7.5 320
12 x 2.5 C* 69.5 x 9.5 1,180
4 x 4 C* 29 x 10.5 5054 x 6 C* 31 x 10.5 6054 x 10 C* 36 x 11.5 8404 x 16 C* 41.5 x 13.5 1,1804 x 25 C 47 x 15 1,6054 x 35 C* 55 x 17 2,5204 x 50 C 66 x 20.5 3,000
4 x (2x1) C* 37 x 12.5 640
Weightapprox.
(kg/km)
Number of cores and nominal cross-section
(mm2)
RHEYFLAT®-N (N)GFLCGOEU-J
*Stocked products
Options• Special cold resistant compound• With integrated optical fiber element• Further options upon request
CONTROL
POWER
BUS
Outer dimensionsapprox.
(mm)
RHEYFLAT®-N NGFLGOEU-JRubber flat festoon cables
2.1 - 3
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
RHEYFLAT®-N NGFLGOEU-J Rubber flat festoon cables
Design
Markinge.g.:RHEYFLAT-N NGFLGOEU-J12 G 1.5 I NEXANS I <VDE>
Applications
StandardsDIN VDE 0250 part 809
300/500 VUsed for festoon and handlingsystems, machine tools, lifts ande-chain cable carrier systems.For applications with highmechanical stress and frequentbending in one plane only.
3. Outer sheathChlorinated rubbercompound 5GM3 acc.to DIN VDE 0207 part 21Colour: black
1. ConductorFlexible stranded plain copper,≤ 25 mm2:extra flexible stranded,class 6 ≥ 35 mm2:flexible stranded, class 5according to DIN EN / IEC 60228
2. InsulationElastomeric EPR rubbercompound 3GI3 acc. to DIN VDE 0207 part 20
DIN VDE 0293-308 / HD 308 S24 cores: brown - green/yellow - grey - black5 cores:blue - brown - green/yellow - black - grey≥ 5 cores: black with white white no .-green/yellow - black
1
2
3
Festoon Cables
EMC Excellent EMC compatibility due to 6 core design and reduced production tolerances acc. to DIN VDE 250 part 1 .
Nominal voltage Uo/U 300/500 VMaximum operating voltage in AC systems Um 500 V Maximum operating voltage in DC systems Vm 750 V
Test voltage (according to DIN VDE 0250 part 809) 2.0 kV in ACCurrent rating (A) according to DIN VDE 0298-4,
see electrical characteristics page 3.2 B
Maximum temperature at the conductor:- in service +90 °C- under short-circuit conditions +250 °C
Maximum surface temperature:- fixed installation -50 °C up to +80 °C- mobile operation -35 °C up to +80 °C
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii according to DIN VDE 0298-3, see construction characteristics page 3.1 E
Tests Bending testFestoon speed up to 180 m/min
RHEYFLAT®-N NGFLGOEU-J
Chemical properties
Electrical and Thermal properties
Oil resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60 332 part 1.
Mechanical properties
Cable characteristics
Flexible Oil resistantGoodGood -35 + 80 °C
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
4 x 1.5* 6.2 x 17.5 2005 x 1.5* 6.2 x 21.5 2407 x 1.5 * 6.2 x 29.0 3608 x 1.5 * 6.2 x 31.5 370
10 x 1.5* 6.5 x 40.0 52012 x 1.5* 6.5 x 47.0 62024 x 1.5* 12.5 x 55.0 1,300
4 x 2.5* 7.5 x 21.0 2805 x 2.5* 7.5 x 27.0 4007 x 2.5* 7.5 x 35.0 5208 x 2.5* 7.5 x 39.0 550
12 x 2.5* 8.0 x 56.0 80024 x 2.5* 16.0 x 68.0 1,850
4 x 4* 9.0 x 26.0 4105 x 4* 9.0 x 32.0 5607 x 4* 9.0 x 42.0 7004 x 6* 9.5 x 29.0 6005 x 6* 9.5 x 35.0 6507 x 6* 9.5 x 42.0 8504 x 10* 11.0 x 33.0 8005 x 10 11.0 x 44.0 1,0004 x 16* 13.0 x 38.0 1,1505 x 16* 13.0 x 50.0 1,4504 x 25* 15.0 x 49.5 1,7005 x 25* 16.0 x 60.0 2,2007 x 25 16.0 x 80.0 3,0604 x 35* 17.0 x 55.0 2,2007 x 35 17.0 x 88.0 3,9004 x 50* 19.0 x 63.0 3,0004 x 70* 22.0 x 71.0 4,0004 x 95* 25.0 x 80.0 5,3004 x 120* 27.0 x 86.0 6,400
Weightapprox.
(kg/km)
Number of cores and nominalcross-section
(mm2)
RHEYFLAT®-N NGFLGOEU-J
Outer dimensionsapprox.
(mm)
*Stocked products24 cores = 6 bunches of 4 cores
POWER
CONTROL
ULFlat PVC cables
2.1 - 6
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
ULFlat PVC cables
Design
Marking
3. Outer sheathPVC Special 105°C
Colour: black or yellow
AssemblyFor easy jacket strippingthreads are placed in eachconductor grouping.
NEXANS FESTOON CABLE - number of core - size - UL Reference number - 105°C - (-40°C) - 600V -OUTDOOR
Applications
StandardsUL subject 2273
600 VPower and control flat cablescan be used on festoon systemsor overhead cranes, and otherhandling systems. Specially designed for indoorand outdoor applications.
1. ConductorFlexible plain copper,16 AWG class Mfrom 14 AWG to 2 AWG class K
2. InsulationColoured coded, special 105°C PVC for easyconductor identification
1
2
3
In accordance with ICEA S 66-524 table K-2:1 - black2 - red3 - blue4 - orange5 - yellow6 - brown7 - red tracer black8 - blue tracer black9 - orange tracer black10 - yellow tracer black11 - brown tracer black12 - black tracer red
Festoon Cables
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Nominal voltage Uo/U 0.6/1 kVMaximum operating voltage in AC systems Um 1.2 kV
Test voltage 3.5 kV - 50 Hz in AC
Max. temperature at the conductor:- in service + 90 °C (105°C)- in short circuit + 150 °C
Max. surface temperature:- fixed installation - 55 °C up to + 105 °C- mobile operation - 40 °C up to + 80 °C
UL Flat PVC Cables
Chemical properties
Electrical and Thermal properties
Oil resistant UL 1581 table 50.156For indoor and outdoor applicationsFlame retaradant UL 1581 Section 1100UV retardant according to UL 62 after 720 hours
Cable characteristics
PbLead FreeCompound
Oil resistantGoodFlexible -40 + 80 °C
Tensile stress of the conductor static 15 N/mm2
dynamic 20 N/mm2
Bending radii 10 x cable thicknessTests reversd bending testTravelling Festoon speed up to 120 m/min
Mechanical properties
Good
UL Flat PVC Cables
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Outer dimensions
(inches)
Number of cores
Approx.Weight
(Ibs/mft)
StrandingNb ofwires AWG
Size (AWG)
StrandingNb of wires
x wirediameter
(mm)
Size (mm2)
NominalThickness(inches)
(inches) (mm)
Outer dimensions
(mm)
Approx.Weight
(kg/km)
Ampacity
(A)
4 C 16 AWG 1.31 65/34 65x 0.160 0.030 0.762 0.60 x 0.20 15.2 x 5.1 20 107 160
8 C 16 AWG 1.31 65/34 65x 0.160 0.030 0.762 1.12 x 0.20 28.5 x 5.1 14 188 280
12 C 16 AWG 1.31 65/34 65x 0.160 0.030 0.762 1.68 x 0.20 42.6 x 5.1 14 282 420
4 C 14 AWG 2.18 41/30 41x 0.254 0.030 0.762 0.63 x 0.22 16.0 x 5.5 27 130 190
8 C 14 AWG 2.08 41/30 41x 0.254 0.030 0.762 1.18 x 0.22 30.0 x 5.5 19 230 340
12 C 14 AWG 2.08 41/30 41x 0.254 0.030 0.762 1.72 x 0.22 43.7 x 5.5 19 350 520
4 C 12 AWG 3.31 65/30 65x 0.254 0.030 0.762 0.72 x 0.24 18.3 x 6.1 33 170 250
4 C 10 AWG 5.26 105/30 105 x 0.254 0.030 0.762 0.89 x 0.27 22.6 x 6.9 44 255 380
4 C 8 AWG 8.37 168/30 168 x 0.254 0.045 1.143 1.20 x 0.37 30.5 x 9.4 60 430 640
4 C 6 AWG 13.3 266/30 266 x 0.254 0.060 1.524 1.45 x 0.43 36.8 x 10.9 82 620 920
4 C 4 AWG 21.15 420/30 420 x 0.254 0.060 1.524 1.70 x 0.50 43.2 x 12.7 104 770 1 150
4 C 2 AWG 33.62 665/30 665 x 0.254 0.060 1.524 2.0 x 0.60 50.8 x 15.3 142 1 310 1 950
2.1 - 2
VCVH6-F Screened PVC flat cables
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
Cores identification
VCVH6-F Screened PVC flat cables
Design
MarkingVCVH6-F Number of cores - cross-sectionvoltage - NEXANS - year - week
Applications
StandardsNexans specification
Control 300/500 VPower 0.6/1 (1.2) kVUsed for hoisting control
systems in festoons onoverhead cranes. Copper screens are efficientagainst electro magneticdisturbances caused by powerand control cables.
power:black-grey-brownearth conductor: green/yellow
control:black with white printednumbers
1. ConductorFlexible plain copper class 5IEC 60228
2. InsulationPVC
3. Screena. Plain copper braidb. Plain copper spinning on
phase cores. Earth core is unscreened.
4. Outer-sheathPVCColour: black
1
2
3.b
4
1
2
3.a
4
Festoon Cables
Control cables:Nominal voltage Uo/U 300/500 VMaximum operating voltage in AC systems Um 500 VCapacitance between cores: 170 nF/kmCapacitance between core and screen: 350 nF/km
Power cables:Nominal voltage Uo/U 0.6/1 kVMaximum operating voltage in AC systems Um 1.2 kV
Test voltage: - Control 2.0 kV - 50 Hz in AC- Power 2.5 kV - 50 Hz in AC
Current rating (A) see electrical characteristics page 3.2 B
Max. temperature at the conductor:- in service + 70 °C - in short circuit + 150 °C
Max. surface temperature:- fixed installation - 35 °C up to + 60 °C - mobile operation - 25 °C up to + 60 °C
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
VCVH6-F Screened PVC Flat Cables
Electrical and Thermal properties
Flexible GoodGoodGood -25 + 60 °CEMI
Good
Tensile stress of the conductor static 15 N/mm2
dynamic 30 N/mm2
Bending radii see construction characteristics page 3.1 ETests Bending testTravelling Festoon speed up to 120 m/min
Chemical properties
Oil, acid and alcaline resistant.For indoor and outdoor applications. Moisture, UV and ozone resistance.Flame-retardant according to IEC 60 332 part 1.
Mechanical properties
Cable characteristics
PbLead free compound
Cop
yrig
ht ©
Jul
y 20
08 -
Nex
ans
4 x 1.5* 18 x 5.5 220
8 x 1.5* 34 x 5.5 430
12 x 1.5* 50 x 5.5 650
4 G 4* 23 x 7 360
4 G 6* 29 x 9 580
4 G 10* 37 x 11 900
4 G 16* 46 x 14 1,280
4 G 25* 50 x 14.5 1,800
4 G 35* 55 x 16 2,300
Weightapprox.
(kg/km)
Number of cores and nominalcross-section
(mm2)
VCVH6-F Screened PVC Flat Cables
Outer dimensionsapprox.
(mm)
CONTROL
POWER
*Stocked products
Options• Other cross-sections on request