+ All Categories

3D COOL

Date post: 19-Jul-2016
Category:
Upload: narupatil
View: 213 times
Download: 0 times
Share this document with a friend
Description:
3D COOL
37
Transcript
Page 1: 3D COOL
Page 2: 3D COOL

Vipul Sabharwal

Vice President - (Sales & Marketing)

Page 3: 3D COOL

-R22

a

Page 4: 3D COOL

Under Preparation before use

Before using the air conditioner, be sure to check and preset as the following.

Remote Controller (RC)

Auto-Restart Function

Auto Turbo Mode

Turbo mode is used to start or stop fast cooling.

6

powered on

6

In case of power resume, auto turbo mode work for 10 min.

Page 5: 3D COOL

Safety precautions

bend

may be

away

around

any

requirements

2

Page 6: 3D COOL

3

Page 7: 3D COOL

4

Timer Turbo Temperature On Sleep

Page 8: 3D COOL

4 55

Remote controller

Remote controller The remote controller transmits signals to the system.

1 ON/OFF BUTTON The appliance will be switched on or Off on pressing this button

2 MODE BUTTON Press this button to select the operation mode.

3 FAN BUTTON Used to select fan speed in sequence

6

auto, high, medium or low.

ROOM TEMPERATURE SETTING BUTTONS

Used to adjust the room temperature and the timer, also real time.

SENSE BUTTON Used to enter fuzzy logic operation directly, regardless of the unit is on or off.

1

3

2

7

4

5

8

13

9

7

8

SWING BUTTON Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.

SLEEP BUTTON

6 12

14 10 11

Used to set or cancel Sleep Mode operation.

9 AROUND U BUTTON Used to set or cancel AROUND U Mode operation.

10 POWER SAVER BUTTON Used to enter or quit POWER SAVER mode

11 TIMER OFF BUTTON Used to cancel the timer operation.

11 12 TIMER ON/CLOCK BUTTON Used to set timer operation and clock.

13 TURBO BUTTON Used to start or stop the fast cooling.

14 DIM BUTTON When you press this button, all the display of indoor unit will be switched off. Press any button to resume display.

5

Indication symbols on LCD: Cooling indicator Auto fan speed 6th sense indicator Signal transmit

Dry indicator

Fan only indicator

Heating indicator

High fan speed Medium fan speed

Low fan speed

Sleep indicator

Around U

Turbo indicator

ON

OFF

Display set timer

Display current time

Display set temperature

Power saver indicator

Note: Each mode and relevant function will be further specified in following pages.

Memory Super silense

Page 9: 3D COOL

Remote controller

How to Insert the Batteries

Note: Use 2 LR03 AAA(1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display becomes dim.

How to Use

6

Page 10: 3D COOL

7

16~30

16 30

1 3

4

2

Page 11: 3D COOL

8

Default position is applicable after power resume

SWING 5

Page 12: 3D COOL

9

Room temperature decrease by 1.5℃ afteroperate for 3 minutes

Around U button

Note: Temperature, airflow and direction are controlled automatically in 6th sense mode.

However, For the on/off, you can choose from -2 to 2, for the inverter you can choose from -7 to 7. if you

still feel uncomfortable.

Page 13: 3D COOL

Operating Instructions

Note: If you don't set the time in 10 seconds after you press TIMER ON button, the remote controller will exit the TIMER ON mode automatically.

A "beep" can be heard. "ON" stops flashing. The TIMER indicator on the indoor unit lights up.

Note: the TIMER ON mode has been canceled.

10

Page 14: 3D COOL

Operating Instructions

SLEEP mode

SLEEP mode SLEEP mode can be set in COOLING HEATING or DRYING operation mode.

This function gives you a more comfortable environment for sleep. In SLEEP mode,

The appliance will stop operation automatically after operating for 8 hours. Fan speed is automatically set at low speed.

*Set temperature will rise by 1 if the appliance operates continuously in mode for hours constantly, then remains steady.

*Note: In cooling mode, if room temperature is 26 or above, set temperature will not change. Note: Heating is NOT available for cooling only air conditioner.

TURBO mode

TURBO mode

Turbo mode is used to reduce the temperature of your room at the highest possible rate, by operating at highest fan speed and changing the set temperature to 18 .

In TURBO mode, you can set airflow direction or timer. If you want to escape from TURBO mode, press TURBO , MODE, FAN, ON/OFF,SLEEP or TEMPERATURE SETTING button, the display will return to the original mode.

*Note: 6TH SENSE button is not available in TURBO mode. The Appliance will continue working in TURBO mode , if you don't exit from it by pressing any of the buttons mentioned above.

11

cooling 1

Power Saver

Whenever this feature is selected, the AC runs at a default temp

of 25 deg & low Fan Speed in cool mode.

•Can be set only when the unit is ON.

•To escape, press any button (Turbo, Fan, On/Off, Temp Setting)

Power Saver

Page 15: 3D COOL

12

Page 16: 3D COOL

Maintenance

Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment.

13

Page 17: 3D COOL

14

16

Page 18: 3D COOL

Troubleshooting The following cases may not always be a malfunction, please check it before asking for service.

s ?

from ing?

Are the ?

s ?

n

15

Page 19: 3D COOL

Troubleshooting chart

16

Page 20: 3D COOL

17

Page 21: 3D COOL

18

same as per provided connecting pipe

Page 22: 3D COOL

Installation instructions

1. Installing the Mounting Plate

Note: The shape of your mounting plate may be different from the one above, but installation method is similar.

2. Drill a Hole for Piping

3. Indoor Unit Piping Installation

Note: When installing the pipe at the directions 1,2 or 4, saw the corresponding unloading piece off the indoor unit base.

19

Below declared Connecting pipe length to be referred as standard length

for Model Sold without Connecting Pipe.

Model Pipe length

1.0T 4 Meter

1.5T 3.2Meter

2.0T 4 Meter

Page 23: 3D COOL

Installation instructions

Piping Joints Thermal Insulation:

Piping Thermal Insulation:

Note: Drain hose is prepared by user.

Piping Connection:

02

Page 24: 3D COOL

Installation instructions

Capacity (Btu/h)

Power Cord Power connecting cord Main power

supply(Note) Type Normal

cross-sectional area

Type Normal

cross-sectional area

4. Connecting of the Cable

Indoor Unit

Note: For some models, it is necessary to remove the cabinet to Indoor unit

connect to indoor unit terminal.

Outdoor Unit

Outdoor unit

The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have

selected.

Caution:

1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of

wiring, refer to the circuit diagram posted on the inside of the access door . 2.Comfirm that the cable thickness is as specified in the power source specification. 3.Check the wires and make sure that they are all tightly fastened after cable connection.

4. Be sure to install an earth leakage circuit breaker in wet or moist area.

Cable Specifications

4)

21

Page 25: 3D COOL

22

Page 26: 3D COOL

23

Page 27: 3D COOL

24

Page 28: 3D COOL

Warranty term

A RELATIONSHIP FOR LIFEWITH 5 YEARS WARRANTY

Whirlpool 3D Cool Air Conditioner

25

Page 29: 3D COOL

Warranty term

26

Page 30: 3D COOL

Warranty term

27

15. "Whirlpool Products without barcode label affixed on the product will not be covered under warranty."

Page 31: 3D COOL

28

Page 32: 3D COOL

29

Page 33: 3D COOL

Installation commissioning

30

Page 34: 3D COOL

31

Page 35: 3D COOL

Installation commissioning

32

Page 36: 3D COOL

33

Page 37: 3D COOL

Declaration on Hazardous Substances : EWaste Rules

Some components used in manufacturing this Air Conditioner contain low content of some

substances classified as hazardous, according to EWaste Rules published by the

Government of India. These do not pose any risk to the conditioning of air inside the room.

Nor does physical contact with the Air Conditioner during the life of the product

endanger health or safety to humans or any living creature. However, if the Air Conditioner

is not disposed safely at the end of its life, inappropriate handling of waste may pose risks

to health and environment. Hence, it is our advice that you contact Whirlpool when you

are ready to discard the product so that we can channelize the appliance and its

components for safe disposal.


Recommended