ALIO’s passion has built a reputation for unmatched quality and performance with our nano-precision motion systems. ALIO’s world leading performance is backed by our NIST referenced ML10 laser interferometer system from Renishaw. ALIO True Nano™ means Proof. 4-Axis Protein Crystallography System ALIO’s integrated 4-axis system was specifically developed to help front line scientists to conduct industry leading x-ray research in protein crystallography. True Nano™ Eight of the world's largest pharmaceutical companies have banded together to run a beam-line at Argonne's Advanced Photon Source (APS) dedicated to determining protein structures and developing new drugs. The discoveries that they and other biomedical researchers at the APS make today provide the foundation for life-saving drugs that doctors will prescribe tomorrow. The X-rays produced by the APS synchrotron and shot through IMCA's beam-lines allow the researchers at these companies to scan thousands of proteins and inhibitor molecules for the next wonder drug. (source: http://www.anl.gov/Media_Center/ArgonneNow/Winter_2009/pharmaceuticals.html) ALIO True Nano™ NIST Traceable Proof v3 16-October 2009 Options: Sample Holder Granite Base for Improved Vibration Isolation Radial: < +/- 1um T.I.R. Axial: < +/- 100nm T.I.R. System Run-Out at XY Integrated 4-Axis Controller EPICS Compatible 110V or 220V Compatible 20nm to 50nm Step Size ± 200nm to ± 300mm Repeatability 4.88nm Resolution 10mm Travel Mount to the Face of the Rotary AI-D4-2500E AI-D2-1200E XY 0.3 arc-sec/sec Speed, min ± 0.2 arc-sec Repeatability 0.02 arc-sec Resolution 360° Continuous Travel R Z Mounted on Z AI-TM-183R 20nm to 50nm Step Size < ± 100nm Repeatability 4.88nm 100mm Resolution Travel Bottom Axis AI-LM-20000 ALIO True Nano™ Specifications
Transcript
  • ALIO’s passion has built a reputation for unmatched quality and performance with our nano-precision motion systems. ALIO’s world leading performance is backed by our NIST referenced ML10 laser interferometer system from Renishaw.

    ALIO True Nano™ means Proof.

    4-Axis Protein Crystallography SystemALIO’s integrated 4-axis system was specifically developed to help front line

    scientists to conduct industry leading x-ray research in protein crystallography.

    True Nano™

    Eight of the world's largest pharmaceutical companies have banded together to run a beam-line at Argonne's Advanced Photon Source (APS) dedicated to determining protein structures and developing new drugs. The discoveries that they and other biomedical researchers at the APS make today provide the foundation for life-saving drugs that doctors will prescribe tomorrow.

    The X-rays produced by the APS synchrotron and shot through IMCA's beam-lines allow the researchers at these companies to scan thousands of proteins and inhibitor molecules for the next wonder drug.

    (source: http://www.anl.gov/Media_Center/ArgonneNow/Winter_2009/pharmaceuticals.html)

    ALIO True Nano™NIST Traceable Proof

    v316-October 2009

    Options:

    Sample Holder

    Granite Base for Improved Vibration Isolation

    Radial: < +/- 1um T.I.R.Axial: < +/- 100nm T.I.R.

    System Run-Out at XY

    Integrated 4-Axis ControllerEPICS Compatible110V or 220V Compatible

    20nm to 50nmStep Size

    ± 200nm to ± 300mmRepeatability

    4.88nmResolution

    10mmTravel

    Mount to the Face of the Rotary

    AI-D4-2500EAI-D2-1200E

    XY

    0.3 arc-sec/secSpeed, min

    ± 0.2 arc-secRepeatability

    0.02 arc-secResolution

    360° ContinuousTravel

    R

    Z

    Mounted on ZAI-TM-183R

    20nm to 50nmStep Size

    < ± 100nmRepeatability

    4.88nm

    100mm

    Resolution

    Travel

    Bottom AxisAI-LM-20000

    ALIO True Nano™ Specifications

  • ALIO True Nano™

    4-Axis Protein Crystallography System

    True Nano™

    v316-October 2009

    Total Radial Run-Out Total Axial Run-Out

    Testing Procedure:

    Radial Run-out: All tests were performed using 8 continuous revolutions of the AI-TM-125R-AB stage with XY stage mounted on the rotary face. Rotational velocity was 1 deg/sec and the data collection was 10 Hz.

    Axial Run-out: All tests were performed using 8 continuous revolutions of the AI-TM-125R-AB stage with XY stage mounted on the rotary face. Rotational velocity was 90 deg/sec and the data collection was 500 Hz.

    The stage was mounted on a granite table in the fully assembled state and placed in the ALIO environmental test room. Prior to testing the stage was soaked in the test environment for 24+ hours and cycled for 2 hours to ensure thermal stability.

  • 1 1

    2 2

    3 3

    4 4

    AA

    BB

    TITL

    E

    SIZ

    ED

    WG

    NO

    RE

    V

    SC

    ALE

    SH

    EE

    TO

    F

    DR

    AW

    N

    CH

    EC

    KE

    D

    MA

    TER

    IAL

    Tole

    ranc

    es:

    S

    urfa

    ce R

    ough

    ness

    :

    x.x `

    .05

    in [1

    .3 m

    m]

    x.xx

    `.0

    1 in

    [0.2

    5 m

    m]

    x.xx

    x `

    .005

    in [0

    .13

    mm

    ]

    R

    MS

    MA

    X.

    Ang

    les `

    0.5~

    1191

    9 W

    I-70

    FR

    ON

    TAG

    E R

    OAD

    NO

    RTH

    , UN

    IT 1

    19, W

    HEA

    T R

    IDG

    E, C

    O 8

    0033

    US

    A(T

    el) 3

    03.3

    39.7

    500

    - SA

    LES

    @A

    LIO

    IND

    US

    TRIE

    S.C

    OM

    - W

    WW

    .ALI

    OIN

    DU

    STR

    IES.

    CO

    M

    ALI

    O IN

    DU

    STR

    IES

    PR

    OP

    RIE

    TAR

    Y IN

    FOR

    MA

    TIO

    N

    ALI

    O S

    TD T

    EM

    PLA

    TE -

    RE

    V 0

    06FI

    NIS

    HS

    EE

    NO

    TES

    4 A

    XIS

    PR

    OTE

    IN

    CR

    YS

    TALL

    OG

    RA

    PH

    Y S

    YS

    TEM

    0010

    -022

    181

    1 001

    B

    NB

    RO

    WN

    12/3

    /200

    9

    A

    122.

    50 m

    m [4

    .823

    in]

    195.

    00 m

    m [7

    .677

    in]

    RO

    TATI

    ON

    AL

    AX

    IS

    CE

    NTE

    RLI

    NE

    q

    XY A

    XIS

    AS

    SE

    MB

    LY

    (MO

    UN

    TED

    TO

    RO

    TAR

    Y F

    AC

    EU

    SED

    FO

    R S

    AM

    PLE

    CE

    NTE

    RIN

    G)

    360

    DEG

    RE

    E C

    ON

    TIN

    UO

    US

    RO

    TAR

    Y(W

    ITH

    INTE

    GR

    ATE

    D S

    LIP

    RIN

    G)

    Z LI

    NE

    AR

    AX

    IS14

    5.00

    mm

    [5.7

    09 in

    ]

    30.0

    0 m

    m [1

    .181

    in]

    20.0

    0 m

    m [0

    .787

    in]

    4X M

    2x0.

    4 - 6

    H x

    2.5

    mm

    SAM

    PLE

    MO

    UN

    TIN

    G T

    APS

    387.

    50 m

    m [1

    5.25

    6 in

    ]

    254.

    00 m

    m [1

    0.00

    0 in

    ]

    50.8

    0 m

    m [2

    .000

    in]

    127.

    00 m

    m [5

    .000

    in]

    25.4

    0 m

    m [1

    .000

    in]

    4X n

    7.14

    mm

    TH

    RU

    v n

    11.1

    3 m

    m x

    20.

    96 m

    mA

    SS

    EM

    BLY

    MO

    UN

    TIN

    G H

    OLE

    SA

    CC

    ESS

    FR

    OM

    TO

    P S

    IDE

    170.

    00 m

    m [6

    .693

    in]

    n5.

    0 m

    m (H

    9) x

    5.0

    mm

    SLI

    P F

    IT F

    OR

    M5

    DO

    WE

    L P

    IN(C

    ENTE

    RE

    D O

    N Z

    AX

    IS S

    TAG

    E)

    340.

    00 m

    m [1

    3.38

    6 in

    ](Z

    AX

    IS S

    TAG

    E LE

    NG

    TH)

    72.5

    0 m

    m [2

    .854

    in]

    20.0

    0 m

    m [0

    .787

    in]

    SA

    MPL

    E M

    OU

    NTI

    NG

    S

    UR

    FAC

    E

    CAB

    LE E

    XIT

    72.5

    0 m

    m [2

    .854

    in]

    STA

    ND

    AR

    D F

    EATU

    RES

    SY

    STE

    M S

    PE

    CIF

    ICA

    TIO

    NS

    :

    RA

    DIA

    L R

    UN

    OU

    T: <

    +/-

    1 um

    TIR

    A

    XIA

    L R

    UN

    OU

    T: <

    +/-

    100

    nm T

    IRR

    OTA

    RY

    AX

    IS -

    AI-T

    M-8

    3R-A

    B-L

    T

    RA

    VE

    L: 3

    60 D

    EG

    RE

    ES

    CO

    NTI

    NU

    OU

    S

    RE

    PE

    ATA

    BIL

    ITY

    : < 0

    .5 A

    RC

    -SE

    C

    MIN

    IMU

    M V

    ELO

    CIT

    Y: 0

    .008

    RP

    MZ

    AX

    IS -

    AI-L

    M-2

    0000

    -T10

    0

    TR

    AV

    EL:

    100

    mm

    R

    EP

    EA

    TAB

    ILIT

    Y: <

    200

    nm

    S

    TEP

    SIZ

    E: 2

    0 - 5

    0 nm

    X &

    Y -

    AI-D

    4-25

    00E

    & A

    I-D2-

    1200

    E:

    T

    RA

    VE

    L: 1

    0 m

    m

    RE

    PE

    ATA

    BIL

    ITY

    : < 3

    50 n

    m

    STE

    P S

    IZE

    : 20

    - 50

    nm

    EN

    VIR

    ON

    ME

    NT:

    STA

    ND

    ARD

    , CLE

    AN

    RO

    OM

    , TE

    MP

    ERA

    TUR

    E: 0

    to 3

    5 D

    EG

    CH

    UM

    IDIT

    Y: 1

    0% to

    80%

    NO

    N-C

    ON

    DE

    NS

    ING

    AS

    SE

    MB

    LY M

    AS

    S: 2

    1 kg

    INC

    LUD

    ES A

    CC

    ESSO

    RIE

    SIN

    TEG

    RA

    TED

    4 A

    XIS

    CO

    NTR

    OLL

    ER

    E

    LEC

    TRO

    NIC

    S C

    HA

    SS

    IS F

    OR

    EA

    SY

    INTE

    GR

    ATI

    ON

    TOO

    L S

    AM

    PLE

    HO

    LDE

    R (O

    PTI

    ON

    AL)

    CU

    STO

    M D

    ESI

    GN

    S F

    OR

    OE

    M IN

    TEG

    RA

    TIO

    N A

    VA

    ILA

    BLE


Recommended