80010922 Page 1 of 4
4-Port AntennaFrequency RangeDual PolarizationHPBWAdjust. Electr. DTset by hand or by optional RCU (Remote Control Unit)
3300–3800 3300–3800
Y1Y1 Y2Y2
X X
65° 65°
2°–12°
936.
5459
ng
mn
04.2
1.06
.01
Sub
ject
to
alte
ratio
n.
4-Port Antenna 3300–3800/3300–3800 65°/65° 17.5/17.5dBi 2°–12°T
Type No. 80010922Left side, highband Y1, connector 1–2Y1, connector 1–2
3300–3800Frequency Range MHz 3300 – 3590 3600 – 3800Gain at mid Tilt dBi 17.5 17.6Gain over all Tilts dBi 17.3 ± 0.4 17.4 ± 0.5Horizontal Pattern:Azimuth Beamwidth ° 66 ± 4.6 63 ± 4.9Front-to-Back Ratio,Total Power, ± 30° dB > 23 > 21
Cross Polar Discriminationover Sector dB > 12.0 > 9.0
Azimuth Beam Port-to-Port Tracking dB < 1.0 < 1.5
Vertical Pattern:Elevation Beamwidth ° 6.0 ± 0.3 5.6 ± 0.3Electrical Downtiltcontinuously adjustable ° 2.0 – 12.0
(Y1 + Y2 simultaneously)Tilt Accuracy ° < 0.4 < 0.4First Upper Side Lobe Suppression dB > 24 > 23
Upper Side Lobe Suppression, 20° Sector above Main Beam
dB > 17 > 18
Cross Polar Isolation dB > 25, typ. > 28Port to Port Isolation dB > 27, typ. > 30 (Y1 // Y2)Max. Effective Powerper Port W 150 (at 50 °C ambient temperature)
Max. Effective PowerPort 1–2 W 300 (at 50 °C ambient temperature)
Values based on NGMN-P-BASTA (version 9.6) requirements.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Page 2 of 4 80010922
936.
5459
ng
mn
04.2
1.06
.01
Sub
ject
to
alte
ratio
n.
4-Port Antenna
Right side, highband Y2, connector 3–4Y2, connector 3–4
3300–3800Frequency Range MHz 3300 – 3590 3600 – 3800Gain at mid Tilt dBi 17.5 17.8Gain over all Tilts dBi 17.3 ± 0.5 17.6 ± 0.4Horizontal Pattern:Azimuth Beamwidth ° 67 ± 3.8 63 ± 4.1Front-to-Back Ratio,Total Power, ± 30° dB > 23 > 25
Cross Polar Discriminationover Sector dB > 12.0 > 9.0
Azimuth Beam Port-to-Port Tracking dB < 1.5 < 1.5
Vertical Pattern:Elevation Beamwidth ° 5.9 ± 0.4 5.6 ± 0.3Electrical Downtiltcontinuously adjustable ° 2.0 – 12.0
(Y1 + Y2 simultaneously)Tilt Accuracy ° < 0.3 < 0.3First Upper Side Lobe Suppression dB > 22 > 22
Upper Side Lobe Suppression, 20° Sector above Main Beam
dB > 17 > 17
Cross Polar Isolation dB > 25, typ. > 28Port to Port Isolation dB > 27, typ. > 30 (Y2 // Y1)Max. Effective Powerper Port W 150 (at 50 °C ambient temperature)
Max. Effective PowerPort 3–4 W 300 (at 50 °C ambient temperature)
Values based on NGMN-P-BASTA (version 9.6) requirements.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
80010922 Page 3 of 4
936.
5459
ng
mn
04.2
1.06
.01
Sub
ject
to
alte
ratio
n.4-Port Antenna
Electrical specifi cations, all systems
Impedance Ω 50VSWR < 1.5Return Loss dB > 14Interband Isolation dB > 28Passive Intermodulation dBc < –150 (2 x 43 dBm carrier)Polarization ° +45, –45Max. Effective Powerfor the Antenna W 400 (at 50 °C ambient
temperature)Values based on NGMN-P-BASTA (version 9.6) requirements.
Wall mounting: No additional mounting kit needed.
Material: Refl ector screen: Aluminum. Fiberglass radome: Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The color of the radome is grey.All screws and nuts: Stainless steel.
Grounding: The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded.
970
| 38.
2
1021
| 40
.2
1051
| 41
.4
2)
Adjustmentmechanismwithintegratedscale
1)
1) 8.5 | 0.32) 64 | 2.5
All dimensionsin mm | inches
Mechanical specifi cations
Input 4 x 4.3-10 female
Connector Position bottom
Adjustment Mechanism 1x, Position bottom continuously adjustable
Wind load (at Rated Wind Speed: 150 km/h)
N | lbf Frontal: 235 | 53Maximal: 255 | 57
Max. Wind Velocity km/hmph
241150
Height / Width / Depth mminches
970 / 179 / 7638.2 / 7.0 / 3.0
Category of Mounting Hardware M (Medium)
Weight kglb
5.4 / 7.6 (clamps incl.)11.9 / 16.7 (clamps incl.)
Packing Size mminches
1320 / 190 / 9552.0 / 7.5 / 3.7
Scope of Supply Panel and 2 units of clampsfor 42–115 mm |
1.7–4.5 inches diameter
Accessories (order separately if required)
Type No. Description Remarksmm | inches
Weight approx.kg | lb
Units per antenna
731651 1 clamp Mast diameter: 28 – 60 | 1.1 – 2.4 0.8 | 1.8 285010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 285010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2737978 1 downtilt kit Downtilt angle: 0° – 13° 2.3 | 5.1 1
Accessories (included in the scope of supply)738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 2
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Any previous data sheet issues have now become invalid.
Page 4 of 4 80010922
936.
5459
ng
mn
04.2
1.06
.01
Sub
ject
to
alte
ratio
n.
4-Port Antenna
Layout of interface:
83 |
3.3
76 |
3.0
64 | 2.5 63 | 2.5
35 | 1.4
6 | 0.2
23 | 0.9
35 |
1.4
41 |
1.6
46 |
1.8
1
Y1
2 4
3
Y1
Y2
Y2
Left Right
Bottom viewAll dimensions in mm | inches
179 | 7.0
Y1 (L
) / Y2 (R) 3300 - 3800
Correlation Table
Frequency range Array Connector
3300–3800 MHz Y1 1–23300–3800 MHz Y2 3–4
Y1 Y2Left Right
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
738546 Page 1 of 1
Mounting HardwareClamp Included in the Scope of Supply
936.
3920
/c
Sub
ject
to a
ltera
tion.
Suitable for mast diameter (mm)[inches]
42 – 115[1.65 – 4.53]
Antenna – mast distance (mm)[inches]
20 – 25[0.79 – 0.98]
Material of clamp and screws Hot-dip galvanized steel / stainless steel
Weight (kg)[lb]
1.1[2.43]
Please note: Kathrein does not recommend to use counter nuts.The additional nuts supplied are only meant as spares.
All dimensions in mm and [inches]
152 [5.98]
100 [3.94]40 [1.57]
72 [2.83]
35 [1.38]
64 [2.52]
125 [4.92]
40 [1
.57]
20–
25
[0.7
9–
0.98
]
42–115
[1.65–4.53]
M10 MA = 25 Nm
M8 MA = 20 Nm
20–25
[0.79–0.98]
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Page 1 of 2
936.
4037
/a
Sub
ject
to
alte
ratio
n.General Instructionsfor Adjustment Mechanism
Description of the adjustment mechanism (protective cap removed):
Manual adjustment procedure:
Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:
For a description of RCU installation please refer to the respective data sheet.
Remove the protective cap and the twist protection completely.
➀ Twist protection.➁ Downtilt spindle with integrated
scale.
➀ Thread for fi xing the pro tectivecap or the RCU (Remote ControlUnit).
➁ Gearwheel for RCU power drive.
To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gear-wheel must be used for alignment.
Set downtilt angle by rotating the gearwheel.
Screw on the twist protection and the protective cap again.
0° – max.°
0° – max.°
1
2
2
1
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
Page 2 of 2
936.
4037
/a
Sub
ject
to
alte
ratio
n.
Installation of the feederline connector and RCU (optional):In order to protect the adjustment mechanism, the protective caps have to be attached during feederline installation!
Carefully place the connector and fi x the nut using a torque-wrench (according to the manufacturers guidelines).
After feederline installation, the optional remote control units (RCUs) can be mounted.
These tools are suitable for 7-16 connectors with a wrench size of 27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with a wrench size of 41 mm | 1.6 inches.
Tighten nuts within a torque range of 25 – 33 Nm depending on connector manufacturers’ specifi cations, respectively the RCU nut with a torque range of 15 – 18 Nm.
Kathrein installation set: Type No. 85010077Set has to be ordered separately!Set consists of three spanners of divers width27, 32 and 41 mm | 1.1, 1.3 and 1.6 inches
32 | 1.3
41 | 1
.627 | 1.1
1/2˝ square actuationaccording toDIN 3120 Form C
All dimensions in mm | inches
Colour coding:Correlation of each RF input to:– the corresponding adjustment mechanism– the frequency range– the polarization
Ventilation hole
Spindle with tilting scale
7-16 female (long neck)
Adjustment mechanism(protective cap removed)
General Instructions for Feederline and RCU Installation for Antennas
Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.
Description of bottom end cap (exemplary picture):
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com
Page 1 of 1
936.
5369
S
ubje
ct t
o al
tera
tion.
Installation of feeder line cables:Tighten the 4.3-10 cable connectors within a torque range of max. 15 Nm depending on connector manufacturers’ specifi cations. The recommended tightening torque of 4.3-10 connectors is 5–8 Nm.For the FlexRET installation, please follow the FlexRET installation instruction on the data sheet.
Installation of Smart Bias Tees:If directly mounted on the antenna, the weight of one Smart Bias Tee must not exceed 440 g | 0.96 lb per antenna connector. It is recommended to only use Kathrein Smart Bias Tees with 4.3-10 connector (type no. 78211590, …, -597).
Hold the Smart Bias Tee housing securely while mounting and tightening the cables. No lateral pressure shall be applied on the Smart Bias Tee when mounting it directly on an antenna neither during the mounting process nor in operational mode.
Ventilation hole
Left/right markingof array positions
FlexRET module
4.3-10 femaleconnector
Colour coding:Correlation of each RF input to:– the frequency range– the polarization– the array position
General Instructions for Feeder Line Installation for Antennas with 4.3-10 Connectors
Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.
Description of bottom end cap (exemplary picture):
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]