4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico ([email protected]) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN Meeting, Schiphol Airport, Amsterdam Michael Enrico Network Engineering & Planning, DANTE
Transcript
Page 1: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

GÉANT2

Network Infrastructure

12th October 2005, 4th EVN-NREN Meeting, Schiphol Airport, Amsterdam

Michael EnricoNetwork Engineering & Planning, DANTE

Page 2: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

• Reminder of Remit

• Procurement history (why so long?)

• Planned GÉANT2 build

• Equipment to do it

• Service overview

Agenda

Page 3: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

• Upgrade GÉANT (1)– Reached end of 4-year funding cycle– Possibility for greater infrastructure ownership (fibre)

• But requires longer term views than hitherto adopted

• Provide support for new services– Not just a bigger IP network…– …support for high-capacity P2P services…– …and (if needed)…lots of them!

• Facilitate (joint) R&D efforts• Extend geographical coverage

GÉANT2 (GN2 I3) Remit

Page 4: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Q4 2003 started drafting connectivity ITTQ1 2004 announced & issued ITTApr/May 2004 first supplier meetings, “DF lighting” modellingJune 2004 started on equipment & NOC ITTSept 2004 GN2 contract (with EC) came into force

first equipment supplier meetingsOct/Nov 2004 equipment suppliers shortlistedDec 2004 connectivity suppliers shortlisted

started hands-on “testing” of final 3 equipment suppliersfirst NREN engineer consultation workshop

Jan/Feb 2005 further equipment “testing”March 2005 second NREN engineer consultation workshopApr-June 2005 connectivity & equipment suppliers decided (LOIs issued)July 2005 contracts being finalised and signedNow building

Review of Procurement

Page 5: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

GÉANT in 2005 (the starting point)Some Facts & Figures…

• 21 POPs• serves 29 European NRENs• 16 x 10G lambda• 13 x 2.5G “lambda”• + some lower speed links • Juniper M160 & M40 routers

in POPs with• NREN accesses at up to

10Gbps (+ backup)• 12G to North America• POP in NY• connections to R&E networks

in:• USA, Canada & Japan• AND Mediterranean• AND Latin America• AND (soon) South East Asia

1 or 2 x E3 to STM-64/10GE

To NREN

WSWS

Leased lambdas(2.5 or 10G)

orSDH circuits

(STM-1 or STM-4)to neighbouring

POPs

Typical GÉANT POP

SwitchedGE/FELAN

M160

PrimaryIP access

BackupIP access

TS ISDN/PSTN

Offers:Many IP servicesEmulated L2 services1 or 2 x E3 to STM-64/10GE

To NREN

WSWSWSWS

Leased lambdas(2.5 or 10G)

orSDH circuits

(STM-1 or STM-4)to neighbouring

POPs

Typical GÉANT POP

SwitchedGE/FELAN

M160

PrimaryIP access

BackupIP access

TSTS ISDN/PSTN

Offers:Many IP servicesEmulated L2 services

Page 6: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

GÉANT(1) → GÉANT2Some New Facts & Figures…

• 25 POPs (+4)• to serve 30 NRENs (+1)• 11600 km of fibre• 140+ ILA sites• 50+ x (own) 10G lambdas• 9 x (leased) 10G lambda• 8 x 2.5G (leased) “lambda”• + some lower speed links • Juniper T640, M160 & M40

routers in POPs with• NREN accesses at up to

10Gbps (+ backup) + P2P• 4 x 10G to North America• POP in NY• connections to other R&E

networks as before…

Page 7: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

GÉANT2POPA

IP Router Switch

n lambdato neighbouring

POP

GÉANT2

POP B

To NREN

n 10 Gbps10 Gbps

n lambdato neighbouring

POP

Primary IPPeering

Backup IPPeering

GÉANT2: A hybrid infrastructure

Page 8: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Typical GÉANT2 POP

Page 9: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Transatlantic (Phase 1)

Page 10: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Transatlantic (Phase 2) [TBC!]

Page 11: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Equipment

Page 12: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Alcatel 1626 Light Manager

• New product.• On paper:

– Up to 96 ’s in ext C-band

– Up to 4500km reach

• P2P, ring and mesh• “Plug & Play” operation

466 x 500 x 290mm

Page 13: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

1626 LM Terminal

BM

DX

1000

CM

DX

TRBD(C)

TRBD(C)

CM

DX

TRBD(C)

TRBD(C)

1

2

12

1

8

1

8

OSC

96 λOFA

OFA

ADD

filter

DROP

filter

TRBD(C)

8

CM

DX

TRBD(C)

1

Optical bit rate, client side:• 9.9532 Gbps.• 10.709 Gbps.• 2.488 Gbps.

Mux/demuxes:• 1:8 channel mux/demux

Mux/demuxes:• 1:12 band mux/demux

EDFA Amplifiers• Amplifies the signal in the (extended) C band

Optical Supervisory Channel• 1510nm – 4Mbps• CLNS (ISO) only over OSC

96 λ

50 Ghz

Page 14: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

1626 LM B-OADM

BM

DX

1100

OSC

96 λOFA

OFA

ADD

filter

DROP

filter

OFA

OFAADD

filter

DROP

filter

BM

DX

1100

CM

DX

TRBD(C)

TRBD(C)

1

11

1

7

TRBD(C)

7

CM

DX

TRBD(C)

1

CM

DX

TRBD(C)

TRBD(C)

1

11

7

1

TRBD(C)

1

CM

DX

TRBD(C)

7

96 λ

ALCT ALCT

Pass-Through

Page 15: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

1626 LM Line Repeater (ILA)

1

2ADD

filter

DROP

filter 2

1

ADD

filter

DROP

filter

ATT/DCU

ATT/DCU

PUMP

PUMP

PUMP

PUMP

OSC

Two stage amplifiers

Page 16: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Transmission Overview

Mux/demuxes:– 1:8 channel mux– 1:12 band mux

Currently supports 50GHz channel spacing

OSC running at 1510nm (4Mbps)

CLNP (ISO) only over OSC

10G transponder options– Tunable over whole band

(VLH reach)– Cheaper version tunable over

two ’s (LH reach)

10GE LAN-PHY transponder available

4 x 2.5G muxponder (SFP)

4 x Any muxponder

Plan to support XFP modules on client side in future

Page 17: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Alcatel 1678 Metro Core Connect (MCC)

575 x 533 x 294mm

• SONET/SDH/OTH switch

• Switching matrix up to 640Gbps– 1+1 protected– VC-4 granularity

• LO matrix available– VC-12 & VC-3 switching

• 16 x 40G line card slots

Page 18: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Alcatel 1678 MCC

• G.ASON (G.7713.2) control plane available• OIF UNI1.0 support• In-band (DCC) or OOB (Ethernet) management

access• TMN Q3 interface used between NMS and NEs• Large MTU (9k) support in the GE cards• 10GE on its way

Page 19: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Alcatel 1678 MCC

• Usual array of line cards:– 4 x STM-64 fixed optics

• Lower port count for longer reach optics• XFP support in future

– 16 x STM-16 using SFPs– 16 x STM-1/4 using SFPs– 4/8/16 x GE (SX/LX) using SFP– 4 x 10GE LAN PHY (around now)– 2 x 10GE LAN PHY VLAN (Feb 2006)– STM-256 (future)

Page 20: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Generic solution:

• Rate adaptive mapping into VC4-nv with flow ctrl. and LCAS, n=1..64;

• up to 4 ports per board

Full rate option:

• Ethernet full rate up to VC4-68v, flow ctrl. and LCAS for n<68

OTH option:

• Mapping into ODU1/2 with flow ctrl.

O/EData

Mapper

4x 10GE LAN board in 1678MCC

DataMapper

MAC

MACO/E

O/E

BKPdrData

Mapper

DataMapper

MAC

MACO/E

Data Mapper Device - GFP-F into VC-4-nv - GFP-F into ODU1/2

4x10GE LAN interface ports

Tomatrix

10GE-LAN interface board in 1678 MCC

Page 21: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Services

Page 22: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

• Continue to support usual IP services– BE, LBE, PIP, mcast (v4), v6, mcast (v6)

• Enhance these with:– implementation of new features as required and available

• e.g. embedded RP for IPv6mcast– improved performance monitoring (JRA1 & SA3)– more automated PIP provisioning (SA3)– network security best practice (JRA2)

• Continue to support emulated L2 P2P services– L2VPNs for lower capacity [“lightpath”] support

• Add portfolio of new L1 and L2 P2P services– cost-effective support for high-capacity [“lightpath”] services

• up to 10G (for now)– emphasis placed on support for Ethernet framing– experiment with translational P2P service support

• e.g. native gigE to GFP VC-4-7v over SDH– experiment with support for various protection modes

Headlines

Page 23: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Circuit Services over GÉANT2

GÉANT2

More resilient IP service

POP A

POP B

POP C

POP D

Features:• uses GFP/VCAT • GE port per instance• more dynamic• sub 1G possible

Primary IP access

Backup IP access

Page 24: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Circuit Services over GÉANT2

GÉANT2

Point-to-point GE (GE access)

POP A

POP B

POP C

POP D

Features:• uses GFP/VCAT • GE port per instance• more dynamic• sub 1G possible

Page 25: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Circuit Services over GÉANT2

GÉANT2

Point-to-point GE (10GE access)

POP A

POP B

POP C

POP D

Features:• uses GFP/VCAT • 10GE port (multiple instances)• use 802.1Q VLAN tags as IDs• more dynamic• sub 1G possible

Page 26: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Circuit Services over GÉANT2

GÉANT2

Point-to-point GE (10G SDH access)

POP A

POP B

POP C

POP D

Features:• uses GFP/VCAT • 10G SDH port• GFP done in NREN• more dynamic• sub 1G possible

Page 27: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Circuit Services over GÉANT2Managed wavelength service

POP A

POP B

POP C

POP D

Features:• 10G only• SONET/SDH or 10GE LAN PHY• static• 10GE is full-rate

GÉANT2

Page 28: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Circuit Services over GÉANT2

GÉANT2

Point-to-point 10GE (and SDH too)

POP A

POP B

POP C

POP D

Features:• uses GFP/VCAT (for 10GE)• NOT line rate! (for 10GE)• more dynamic• sub 10G possible

Page 29: 4 th EVN-NREN Meeting, 12 th Oct 2005, Schiphol – Michael Enrico (michael.enrico@dante.org.uk) GÉANT2 Network Infrastructure 12 th October 2005, 4 th EVN-NREN.

4th EVN-NREN Meeting, 12th Oct 2005, Schiphol – Michael Enrico ([email protected])

Questions ?