+ All Categories
Home > Documents > 405_1200_048_2 - Commissioning Manual - Rel 2_00

405_1200_048_2 - Commissioning Manual - Rel 2_00

Date post: 13-Apr-2016
Category:
Upload: bartolome-carlos-orfila-nadal
View: 9 times
Download: 1 times
Share this document with a friend
Description:
Consola ESA
146
CE Terminals Commissioning manual 405.1200.048.2 - Rel.: 2.00 of 15/05/2003
Transcript
Page 1: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CE Terminals

Commissioning manual

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

Page 2: 405_1200_048_2 - Commissioning Manual - Rel 2_00

ESA elettronica S.P.A. reserves the right to change the information contained in this document without notice. The information repre-sents no obligation on the part of the company.

All products referred to are covered by the appropriate trademark and/or copyright legislation.

Page 3: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

i

Quality Assurance

ESA elettronica’s quality control system has been certified by the CSQ, EQNet and ITQS (certification N° 9115.ESAE) as complying with UNI EN ISO 9001 standards.

These represent the most comprehensive set of standards within the interna-tional framework of ISO and cover every aspect of the life-cycle of the product (planning, development, production, installation and customer care).

All the products described in this manual comply with the following standards:electromagnetic compatibility (EMC):

• emissions EN 61000-6-4 (2001)• immunity EN 61000-6-2 (2001)

and thus are in line with:

Council Directives89/336/EEC 92/31/EEC 93/68/EEC

Tests carried out for CE-mark.

Immunity Disturbance characteristics Standard

To disturbances

Electrostatic discharge:ContactAir

EN61000-4-24kV8kV

Radio-FrequencyENV50140/ENV5014110 V/m

Rapid transitories:Power supplyI/O serial

EN61000-4-42 kV1 kV

Impulsive transitories Common and Differential mode

EN61000-4-5

To radiodisturbances

EmissionEN55011Level of radio disturbance B

Page 4: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 5: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

iii

Contents

Foreword The manual ................................................................... F-1Its purpose .................................................................... F-1Conventions .................................................................. F-1

Introduction What is a CE Video Terminal ........................................ I-1

General information on electromagnetic compatibility (EMC)

Contents........................................................................ 1-1Laying cables ................................................................ 1-2Shielding of cables ........................................................ 1-2Earthing of shielding and electronic circuits .................. 1-2Switching of capacitive loads ........................................ 1-2Switching off inductive loads......................................... 1-2Disturbance suppression circuit - RC and DIODE ........ 1-3

Power Supply Contents........................................................................ 2-1Connection pins ............................................................ 2-2Recommended connection ........................................... 2-2Connections to be avoided ........................................... 2-3

Video terminal VT330CE

Contents........................................................................ 3-1Technical characteristics............................................... 3-2Front view ..................................................................... 3-4Customizing label.......................................................... 3-6Rear view ...................................................................... 3-7Dimensions and Cut-out................................................ 3-9Accessories................................................................... 3-10

Video terminal VT585CE

Contents........................................................................ 4-1Technical characteristics............................................... 4-2Front view ..................................................................... 4-4Customizing label.......................................................... 4-5Rear view ...................................................................... 4-6Dimensions and Cut-out................................................ 4-8Accessories................................................................... 4-9Calibration of Touch Screen.......................................... 4-9

Video terminal VT595CE

Contents........................................................................ 5-1Technical characteristics............................................... 5-2Front view ..................................................................... 5-4Customizing label.......................................................... 5-5Rear view ...................................................................... 5-6Dimensions and Cut-out................................................ 5-8Accessories................................................................... 5-9Calibration of Touch Screen.......................................... 5-9

Page 6: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CONTENTS

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

iv

Inserting customized labels

Contents........................................................................ 6-1Label ............................................................................. 6-2Warnings ....................................................................... 6-2Notes............................................................................. 6-4

Mounting the terminal within the container

Contents........................................................................ 7-1Using nuts ..................................................................... 7-2

Communication ports Contents........................................................................ 8-1General notes................................................................ 8-2COM1 serial port ........................................................... 8-3LPT parallel port............................................................ 8-4Mouse PS/2 port ........................................................... 8-5Keyboard PS/2 port....................................................... 8-6Ethernet network port.................................................... 8-7USB serial port .............................................................. 8-8MSP, ASP and CAN serial ports ................................... 8-9

VTCE video terminal accessories

Contents........................................................................ 9-1Adapter PC 25F <-> VTCE 9M ..................................... 9-3Cell battery .................................................................... 9-4Ethernet crossover cable .............................................. 9-5Null modem cable PC 25F <-> VTCE 9F ...................... 9-6Null modem cable PC 9F <-> VTCE9F ......................... 9-7Protfilm10/12 ................................................................. 9-8CIB board - MSP, ASP.................................................. 9-10CIB board - MSP, CAN ................................................. 9-11

Basic concepts Contents........................................................................ 10-1RAM .............................................................................. 10-2Flash Disk ..................................................................... 10-2Storage Card................................................................. 10-2Saving the Registry ....................................................... 10-2

Using the system Contents........................................................................ 11-1Calibrating the Touch Screen........................................ 11-2Enabling communication with remote terminals............ 11-3Direct PC / VTCE connection using Ethernet................ 11-4Connection in Ethernet.................................................. 11-10PC / VTCE connection using serial port........................ 11-14Automatic execution of applications.............................. 11-19Managing the Fonts ...................................................... 11-21

Resistance to chemical substances

Contents........................................................................ 12-1Chemical substances .................................................... 12-2Cleaning the VTCE ....................................................... 12-7

Software compatibility Contents........................................................................ 13-1Movicon......................................................................... 13-2

Page 7: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

v

Minimum HW requirements........................................... 13-2Zenon............................................................................ 13-3

Creating a project with Movicon

Contents........................................................................ 14-1Installation..................................................................... 14-2The project .................................................................... 14-3Transferring Movicon files to a VTCE ........................... 14-3Transferring a project to a VTCE .................................. 14-4

Creating a project with ZenOn

Contents........................................................................ 15-1Installation..................................................................... 15-2The project .................................................................... 15-3Choosing the device to connect to the VTCE ............... 15-5Entering the variables ................................................... 15-8Transfer of ZenOn files to VTCE terminal ..................... 15-11Transferring a project to the VTCE terminal.................. 15-12

Technical support Contents........................................................................ 16-1International Customer Care......................................... 16-2International Product Returns ....................................... 16-2

Index ...................................................................................... IA-1

Page 8: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 9: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

F-1

Foreword

The commissioning manual is valid for all types of CE Video Terminal.

The manual The commissioning manual is a source of information on securing and con-necting the terminals, on the available optional accessories and on the ini-tial software settings needed to ensure the panels work properly.

Its purpose The manual contains all the notions, concepts and examples necessary to be able to install quickly and easily.

Conventions Below are listed the symbols and styles found in the manual together with their respective meanings:

File > Open This style is used to indicate a menu option. It represents the complete path necessary for reaching the option required.

Label This style is used to indicate a data input field.

PLC Programmable logic control or other intelligent device equipped with a serial connection.

Device Intelligent device or PLC equipped with a serial connec-tion.

Identifies a key or touch button.

Identifies an option within a window.

Identifies a folder.

Indicates an important point that requires attention.

There is a danger that the equipment will be damaged.

Page 10: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 11: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

I-1

Introduction

What is a CE Video Terminal

A CE VIDEO TERMINAL (VTCE) is a device that is part of the Handheld PC category with which the Windows® CE operating system programmed and can be loaded and which can run supervisory programs that control or simply monitor a productive process. It can send commands using con-figured by the user; it can send data determining the process on hand and can display information deriving from the productive process. The informa-tion can be in the form of an Alarm, an Information (Info-) Message or in binary data format.

The VTCEs can be divided into two groups: those with a keyboard and those without but equipped with a Touch Screen.

All VTCEs can be supplemented with accessories to boost and broaden their performance, for example, by using the CIB board a connection can be made to a CAN network and/or to over 90% of devices on the market that are supported by ESA.

To operate the VTCE a project needs to be created (using supervisory or similar programs) that must be loaded into the VTCE (see “Chapter 13 -> Software compatibility“).

For detailed information on individual VTCEs see the relevant chapters below.

A characteristic of VTCE terminals is to have startup time of up to 30 seconds from switching on.

While in the startup phase the display remains inactive and there is nothing to be seen.

Page 12: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 13: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

1-1

Chapter 1 General information on electromagnetic compatibility (EMC)

Contents Page

Laying cables 1-2

Shielding of cables 1-2

Earthing of shielding and electronic circuits 1-2

Switching of capacitive loads 1-2

Switching off inductive loads 1-2

Disturbance suppression circuit - RC and DIODE 1-3

This chapter consists of 4 pages.

Page 14: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 1General information on electromagnetic compatibility (EMC)

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

1-2

Electronic devices are being increasingly used in automated systems. pro-grammable controllers (like the PLC) belong to this category, as do Man-machine-interface systems (e.g. the CE Video Terminal), control sys-tems (e.g. diagnostic terminals), interface elements (e.g. interface boards) and AC-DC drives. Together with this type of electronic apparatus, you find installed classical electro-mechanical devices like contactors, elec-tro-valves, motors etc.Electrical disturbances caused by the operation of these devices can com-promise the smooth functioning and the length of the working life of the electronic devices present on the same switchboard or the same plant. To get the best out of both the electrical and the electronic devices it is neces-sary to reduce electrical disturbance.

Laying cables Remember to lay measurement, monitoring and communication cables so that they are kept apart from power cables. Power cables laid close and par-allel to communication cables can cause coupling voltages that are strong enough to disturb or destroy electronic components.

Shielding of cables

It is essential to use suitably shielded cables for communication signal con-nections (total shielding is recommended). The shielding must be con-nected to the zero potential.

Earthing of shielding and electronic circuits

With many devices the "0V" is connected to the earth. The signal ground must be earthed but it is best to separate the ground of the shields and cir-cuits from that of the power circuits. Note that the earth can only perform its function if the "Resistance of the earth circuit" is within the max. limits prescribed.

Switching of capacitive loads

The current peaks which occur when capacitive loads are switched on can damage or destroy control devices. Furthermore, the high-frequency com-ponent of the current peak can cause serious disturbance in electronic cir-cuits as a result of inductive coupling between the connection cables.

Switching off inductive loads

When an inductive load is switched off, the magnetic energy stored tends to oppose this, discharging a voltage peak down the line which can damage or destroy the control device. Furthermore, the high-frequency component of the voltage peak can cause disturbance caused by capacitive coupling between the connection cables. The physical structure and characteristics of an inductive load make it impossible to carry out switching without disturbance unless suitable mea-sures are taken. The disturbance can be at least partially suppressed by fit-ting a suitable disturbance-suppression module in parallel with the inductive load. The disturbance-suppression module must not constitute an additional load during the work phase. Electrical disturbance is propagated both through the connection cables and electromagnetic transmission. If the disturbance is propagated by cable or electromagnetic transmission, it is much more difficult to suppress at the inputs to the units in the danger zone than it is to suppress the disturbance at its source. If the disturbance is cre-

Page 15: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

1-3

ated by connection cables or by electronic transmission, it is much more difficult to suppress it at the inputs of the devices in dangerous areas than at source,

If possible, disturbance should be suppressed at source.

Disturbance suppression circuit - RC and DIODE

In the following tables there are the specifications of the disturbance sup-pression filter ciruits.

Table 1.1: Disturbance suppression circuit RC

Circuit Advantages Disadvantages

The residual component has a very low harmonic wave form component.

The best results are obtained by sizing the R/C suitably.

The residual overvoltage can be limited to the very low values by optimizing the sizing.

Volume directly proportional to the inductance and power of the load.

Switch-off time delay very low.Optimal suppression is obtained as a direct consequence of a significant de-energizing delay.

The effectiveness of the disturbance suppression is not affected by the volt-age value. No switch-on delay.

The presence of the capacitor causes a high load current peak when switching on (and can cause pasting of the con-tact if undersized).

Suitable for both AC and DC; no prob-lem with reversed polarity.

The RC circuit constitutes an additional load when used with AC.

No arc (low energy) on switching con-tact.

--

Table 1.2: Disturbance suppression circuit DIODE

Circuit Advantages Disadvantages

Very compact. High switch-off delay time.

No residual voltage (total damping of disturbance impulse).

For direct current (DC) applications only.

Easy to size. Polarity must be respected.

--Switch-off delay can lead to the forma-tion of a strong electric arc.

--Sensitive to disturbance voltage pulses in power supply circuit.

C

RUb

S

L

C R

Ub

S

L D

D

Page 16: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 17: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

2-1

Chapter 2 Power Supply

Contents Page

Connection pins 2-2

Recommended connection 2-2

Connections to be avoided 2-3

This chapter consists of 4 pages.

Page 18: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 2Power Supply

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

2-2

Use a 24VDC (18..32Vdc) power supply unit to power the VTCE.

Connection pins

Check all connections before switching on.

Recommended connection

We recommend a wiring scheme as set out below in the interests of avoid-ing damaging the VTCE.

Correct earthing is essential.

Table 2.1: 4 pin Power Supply Connector

Connector Pin Meaning

1 Input power +24Vdc

2 Input power 0Vdc

3 Not connected

4 Earth protection

4 3 2 1

N.C. 24VDC- +

Table 2.2: Power supply with 0Vdc connected to PE

~

+-24V

3

+24VPE

0V

VTCE

PLC

PENL1

4

12

Page 19: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

2-3

Connections to be avoided

The connections illustrated below must not be made as they may cause the VTCE to be damaged.

The above configurations will seriously damage certain compo-nents of the VTCE.

Beware of appliances with the POSITIVE connected to PE.

It is vital that the earth of the devices connected to the serial and/or parallel communication ports have the same voltage as the

0V supply of the VTCE. The circulation of current between the 0V sup-ply and the earth of the communication ports could damage certain components of the VTCE or of the devices connected it.

Table 2.3: Connections to be avoided

~

+- 24V

PENL1

~

+- 24V

PENL1

Page 20: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 21: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-1

Chapter 3 Video terminal VT330CE

Contents Page

Technical characteristics 3-2

Front view 3-4

Customizing label 3-6

Rear view 3-7

Dimensions and Cut-out 3-9

Accessories 3-10

This chapter consists of a total of 10 pages.

Page 22: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 3Video terminal VT330CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-2

Technical characteristics

The following table lists the principal technical characteristics of the prod-uct in question.

Code of terminal Characteristics of the terminalVT330CE 0T0 00VT330CE 1T0 00VT330CE 2T0 00Display ▼ ▼ ▼

Type LCD 65k colors TFT ● ● ●

Touch screen --Representational format Graphic ● ● ●

Resolution [pixels] 640 x 480 (10,4”) ● ● ●

BacklightingType Lamp CCFL ● ● ●

Min. lamp-life at 25°C [hours] 20000 ● ● ●

ProcessorType Intel® Strong ARM Sa1110 206Mhz ● ● ●

KeyboardNon-customizable function keys 12 ● ● ●

Customizable function keys 16 ● ● ●

Function key LEDs 16 ● ● ●

Alphanumeric keys 27 ● ● ●

Operational keys 19 ● ● ●

Operational key LEDs 3 ● ● ●

Diagnostic LEDs 3 ● ● ●

Page 23: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-3

System memory ▼ ▼ ▼

Data memory (RAM) 64Mb ● ● ●

Resident flash array 32Mb ● ● ●

InterfacesMSP serial port RS232/RS422/RS485/TTY-20mA ● ●

ASP serial port RS232/RS485 ●

Standard serial port RS232 ● ● ●

Parallel port Bidirectional ● ● ●

USB port 1 (Master) ● ● ●

Mouse PS/2 port 1 ● ● ●

Keyboard PS/2 port 1 ● ● ●

PCMCIA Type I slot 2 ● ● ●

AccessoriesConnectable accessories See table ”Chapter 9” ● ● ●

ClockClock Hardware (With back-up battery) ● ● ●

Networks

IntegratedEthernet 10/100Mbit RJ45 ● ● ●

CAN Open (Optoisolated interface) ●

Technical dataPower supply 24Vdc (18..32Vdc)Power absorbed at 24Vdc 20WProtection fuse Ø5x20mm - 3,15A Quick Blow FProtection level IP65 (front-end)Working temperature 0..50°CStorage and transportation temperature -20..+65°CHumidity (non-condensing) <85%Weight 4000grDimensionsExternal L x H x D [mm] 435 x 260 x 90Cut-out L x H [mm] 403 x 240CertificationCertifications and approvals CEInstalled softwareOperating system Microsoft® Windows® CE 3.0

Code of terminal Characteristics of the terminalVT330CE 0T0 00VT330CE 1T0 00VT330CE 2T0 00

Page 24: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 3Video terminal VT330CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-4

Front view

Key Function

1 Display

2 Alphanumeric + operative keys

3 F-keys with no LED

4 F-keys with one LED (At present the LEDs are not managed)

5F-keys with one LED (From F25 to F28 all LEDs currently not managed)

6X0 LED. Blinks when communication error is detected(At present not managed)

7 Power LED. Lights up when power in ON

8Battery LED. Lights up when the battery has nearly run out(At present not managed)

Starts input (At present not managed)

Confirms setting of data

Page upWhen in setting phase, edits dynamic text

Page 25: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-5

Page downWhen in setting phase, edits dynamic text

Moves the cursor between settable fieldsWhen in setting phase, moves cursor to the left of the field

Moves the cursor between settable fieldsWhen in setting phase, moves cursor to the right of the field

Quits: setting of data, info-messages, sequence directory, com-munication driver

Displays info-messages (At present not managed)

Displays ISA alarms (At present not managed)

Displays according to context: information message help, alarm help or page help (At present not managed)

Acknowledgment of ISA alarms on display(At present not managed)

Print the entire display area

No predefined function (At present not managed)

No predefined function

No predefined function

No predefined function

In setting phase restores the initial value of the field

+ Acknowledges all ISA alarms (At present not managed)

+Displays the contents of the alarm buffer (At present not managed)

Key Function

Page 26: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 3Video terminal VT330CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-6

Customizing label

The total thickness of the label must not exceed 125µm (microme-ters). Do not use either stiff materials or glues.

Before starting to insert the customized label, see “Chapter 6 -> Inserting customized labels“.

Position Function - Dimensions L x H (mm)

1 ESA Logo, VT Model - 162 x 13

2 F-key customization F - 17 x 207

21

Page 27: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-7

Rear view

Table 3.1: Connector lay-out (Part 1 of 2)

Position Function

A Standard serial port

B Mouse PS/2 port

C CAN port (Optional with CIB board)

DASP serial port for communicating with PC or other devices (Optional with CIB board)

A

C

D

E

B

H

I

F

G

M

L

Page 28: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 3Video terminal VT330CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-8

EMSP serial port for communicating with PLC/PC (Optional with CIB board)

F LPT port for connecting printer

G Keyboard PS/2 port

H Ethernet network 10/100Mbit RJ45

I USB serial port

L PCMCIA Type I slot

M Power supply connector

Table 3.1: Connector lay-out (Part 2 of 2)

Position Function

Page 29: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-9

Dimensions and Cut-out

Page 30: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 3Video terminal VT330CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

3-10

To fix the sealing gasket and secure the VTCE to the container see “Chapter 7 -> Mounting the terminal within the container“.

Where accessories need to be fixed in or onto the VTCE terminal, you are advised to do this before securing the VTCE to its con-

tainer.

Accessories Any accessories should be mounted in accordance with the instructions in the relevant chapter (see “Chapter 9 -> VTCE video terminal accessories“).

Page 31: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-1

Chapter 4 Video terminal VT585CE

Contents Page

Technical characteristics 4-2

Front view 4-4

Customizing label 4-5

Rear view 4-6

Dimensions and Cut-out 4-8

Accessories 4-9

Calibration of Touch Screen 4-9

This chapter consists of 12 pages.

Page 32: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 4Video terminal VT585CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-2

Technical characteristics

The following table lists the principal technical characteristics of the prod-uct in question.

Code of terminal Characteristics of the terminalVT585CE 0T0 00VT585CE 1T0 00VT585CE 2T0 00Display ▼ ▼ ▼

Type LCD 65k colors TFT ● ● ●

Touch screen Analog ● ● ●

Representational format Graphic ● ● ●

Resolution [pixels] 640 x 480 (10,4”) ● ● ●

BacklightingType Lamp CCFL ● ● ●

Min. lamp-life at 25°C [hours] 20000 ● ● ●

ProcessorType Intel® Strong ARM Sa1110 206Mhz ● ● ●

KeyboardNon-customizable function keys --Customizable function keys --Function key LEDs --Alphanumeric keys --Operational keys --Operational key LEDs --Diagnostic LEDs --

Page 33: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-3

System memory ▼ ▼ ▼

Data memory (RAM) 64Mb ● ● ●

Resident flash array 32Mb ● ● ●

InterfacesMSP serial port RS232/RS422/RS485/TTY-20mA ● ●

ASP serial port RS232/RS485 ●

Standard serial port RS232 ● ● ●

Parallel port Bidirectional ● ● ●

USB port 1 (Master) ● ● ●

Mouse PS/2 port 1 ● ● ●

Keyboard PS/2 port 1 ● ● ●

PCMCIA Type I slot 2 ● ● ●

AccessoriesConnectable accessories See table ”Chapter 9” ● ● ●

ClockClock Hardware (With back-up battery) ● ● ●

Networks

IntegratedEthernet 10/100Mbit RJ45 ● ● ●

CAN Open (Optoisolated interface) ●

Technical dataPower supply 24Vdc (18..32Vdc)Power absorbed at 24Vdc 20WProtection fuse Ø5x20mm - 3,15A Quick Blow FProtection level IP65 (front-end)Working temperature 0..50°CStorage and transportation temperature -20..+65°CHumidity (non-condensing) <85%Weight 4000grDimensionsExternal L x H x D [mm] 346 x 260 x 90Cut-out L x H [mm] 314 x 240CertificationCertifications and approvals CEInstalled softwareOperating system Microsoft® Windows® CE 3.0

Code of terminal Characteristics of the terminalVT585CE 0T0 00VT585CE 1T0 00VT585CE 2T0 00

Page 34: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 4Video terminal VT585CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-4

Front view

All buttons and signals are defined via the programming software (see “Chapter 13 -> Software compatibility“).

Page 35: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-5

Customizing label

The total thickness of the label must not exceed 125µm (microme-ters). Do not use either stiff materials or glues.

Before starting to insert the customized label, see “Chapter 6 -> Inserting customized labels“.

Position Function - Dimensions L x H (mm)

1 ESA Logo, VT Model - 160 x 12

1

Page 36: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 4Video terminal VT585CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-6

Rear view

Table 4.1: Connector lay-out (Part 1 of 2)

Position Function

A Standard serial port

B Mouse PS/2 port

C CAN port (Optional with CIB board)

DASP serial port for communicating with PC or other devices (Optional with CIB board)

A

C

D

E

B

H

I

F

G

M

L

Page 37: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-7

EMSP serial port for communicating with PLC/PC (Optional with CIB board)

F LPT port for connecting printer

G Keyboard PS/2 port

H Ethernet network 10/100Mbit RJ45

I USB serial port

L PCMCIA Type I slot

M Power supply connector

Table 4.1: Connector lay-out (Part 2 of 2)

Position Function

Page 38: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 4Video terminal VT585CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-8

Dimensions and Cut-out

Page 39: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-9

To fix the sealing gasket and secure the VTCE to the container see “Chapter 7 -> Mounting the terminal within the container“.

Where accessories need to be fixed in or onto the VTCE terminal, you are advised to do this before securing the VTCE to its con-

tainer.

Accessories Any accessories should be mounted in accordance with the instructions in the relevant chapter (see “Chapter 9 -> VTCE video terminal accessories“).

Calibration of Touch Screen

The screen of VT585CE is made of resistive, sensitive glass; fot this type of glass to work properly it requires a calibration procedure (the terminal is already calibrated when supplied), that is, the resistive area of the glass has to be adjusted to the visible are of the display.

Should it be thought necessary to repeat the calibration procedure this can be done by following the instructions set out below.

The procedure must be carried out with great care as the preci-sion ofthe keys area depends on the callibration.

Page 40: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 4Video terminal VT585CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-10

How to perform the calibration procedure:

• Make sure the VTCE is not connected to the power supply• Remove the back cover• Identify jumper X9

• Position X9 as shown in the figure.• Reconnect the power supply and switch on the terminal; the following

mask appears:

Calibration

Page 41: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

4-11

The calibration has finished:• Switch off the terminal• Reposition X9 in its original position• Replace the back cover• Switch on the terminal again

The calibration procedure has finished; if the calibration has be carried out wrongly or imprecisely, repeat the procedure.

Page 42: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 43: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-1

Chapter 5 Video terminal VT595CE

Contents Page

Technical characteristics 5-2

Front view 5-4

Customizing label 5-5

Rear view 5-6

Dimensions and Cut-out 5-8

Accessories 5-9

Calibration of Touch Screen 5-9

This chapter consists of 12 pages.

Page 44: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 5Video terminal VT595CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-2

Technical characteristics

The following table lists the principal technical characteristics of the prod-uct in question.

Code of terminal Characteristics of the terminalVT595CE 0T0 00VT595CE 1T0 00VT595CE 2T0 00Display ▼ ▼ ▼

Type LCD 65k colors TFT ● ● ●

Touch screen Analog ● ● ●

Representational format Graphic ● ● ●

Resolution [pixels] 800 x 600 (12,1”) ● ● ●

BacklightingType Lamp CCFL ● ● ●

Min. lamp-life at 25°C [hours] 10000 ● ● ●

ProcessorType Intel® Strong ARM Sa1110 206Mhz ● ● ●

KeyboardNon-customizable function keys --Customizable function keys --Function key LEDs --Alphanumeric keys --Operational keys --Operational key LEDs --Diagnostic LEDs --

Page 45: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-3

System memory ▼ ▼ ▼

Data memory (RAM) 64Mb ● ● ●

Resident flash array 32Mb ● ● ●

InterfacesMSP serial port RS232/RS422/RS485/TTY-20mA ● ●

ASP serial port RS232/RS485 ●

Standard serial port RS232 ● ● ●

Parallel port Bidirectional ● ● ●

USB port 1 (master) ● ● ●

Mouse PS/2 port 1 ● ● ●

Keyboard PS/2 port 1 ● ● ●

PCMCIA Type I slot 2 ● ● ●

AccessoriesConnectable accessories See table ”Chapter 9” ● ● ●

ClockClock Hardware (With back-up battery) ● ● ●

Networks

IntegratedEthernet 10/100Mbit RJ45 ● ● ●

CAN Open (Optoisolated interface) ●

Technical dataPower supply 24Vdc (18..32Vdc)Power absorbed at 24Vdc 20WProtection fuse Ø5x20mm - 3,15A Quick Blow FProtection level IP65 (front-end)Working temperature 0..50°CStorage and transportation temperature -20..+65°CHumidity (non-condensing) <85%Weight 4000grDimensionsExternal L x H x D [mm] 401 x 390 x 90Cut-out L x H [mm] 369 x 288CertificationCertifications and approvals CEInstalled softwareOperating system Microsoft® Windows® CE 3.0

Code of terminal Characteristics of the terminalVT595CE 0T0 00VT595CE 1T0 00VT595CE 2T0 00

Page 46: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 5Video terminal VT595CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-4

Front view

All buttons and signals are defined via the programming software (see “Chapter 13 -> Software compatibility“).

Page 47: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-5

Customizing label

The total thickness of the label must not exceed 125µm (microme-ters). Do not use either stiff materials or glues.

Before starting to insert the customized label, see “Chapter 6 -> Inserting customized labels“.

Position Function - Dimensions L x H (mm)

1 ESA Logo, VT Model - 160 x 12

1

Page 48: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 5Video terminal VT595CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-6

Rear view

Table 5.1: Connector lay-out (Part 1 of 2)

Position Function

A Standard serial port

B Mouse PS/2 port

A

C

D

E

B

H

I

F

G

M

L

Page 49: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-7

C CAN port (Optional with CIB board)

DASP serial port for communicating with PC or other devices (Optional with CIB board)

EMSP serial port for communicating with PLC/PC (Optional with CIB board)

F LPT port for connecting printer

G Keyboard PS/2 port

H Ethernet network 10/100Mbit RJ45

I USB serial port

L PCMCIA Type I slot

M Power supply connector

Table 5.1: Connector lay-out (Part 2 of 2)

Position Function

Page 50: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 5Video terminal VT595CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-8

Dimensions and Cut-out

Page 51: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-9

To fix the sealing gasket and secure the VTCE to the container see “Chapter 7 -> Mounting the terminal within the container“.

Where accessories need to be fixed in or onto the VTCE terminal, you are advised to do this before securing the VTCE to its con-

tainer.

Accessories Any accessories should be mounted in accordance with the instructions in the relevant chapter (see “Chapter 9 -> VTCE video terminal accessories“).

Calibration of Touch Screen

The screen of VT595CE is made of resistive, sensitive glass; fot this type of glass to work properly it requires a calibration procedure (the terminal is already calibrated when supplied), that is, the resistive area of the glass has to be adjusted to the visible are of the display.

Should it be thought necessary to repeat the calibration procedure this can be done by following the instructions set out below.

The procedure must be carried out with great care as the preci-sion ofthe keys area depends on the callibration.

Page 52: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 5Video terminal VT595CE

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-10

How to perform the calibration procedure:

• Make sure the VTCE is not connected to the power supply• Remove the back cover• Identify jumper X9

• Position X9 as shown in figure.• Reconnect the power supply and switch on the terminal; the following

mask appears:

Calibration

Page 53: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

5-11

The calibration has finished:• Switch off the terminal• Reposition X9 in its original position• Replace the back cover• Switch on the terminal again

The calibration procedure has finished; if the calibration has be carried out wrongly or imprecisely, repeat the procedure.

Page 54: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 55: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

6-1

Chapter 6 Inserting customized labels

Contents Page

Label 6-2

Warnings 6-2

Notes 6-4

This chapter consists of 4 pages.

Page 56: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 6Inserting customized labels

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

6-2

VTCE terminals are supplied with labels already set in the appropriate spaces.

If it is necessary to customize keys, the logo or the model the labels can be replaced with the neutral ones supplied in kit with the terminal (only for F-keys) or by inserting labels of other materials provided they conform with the points set out below.

Failure to follow the following indications may cause damage to the terminal.

Label The label must be of a material that is flexible and does not exceed 125µm (micrometers).

Use neither stiff materials nor glues.

Warnings Before starting to insert the customized label the following points MUST BE observed:

• Remove the label already inserted.• Follow the indications set out in the paragraph Label.• Do not use compressed air to help insert the label. • Do not use rigid or other instruments to insert the label.• Do not fold the label between the terminal and the casing. The following

figures illustrate the correct and the incorrect positions for the label.

Correct insertion:

The label illustrated is free and creates no tension on the keyboard.

Container Metal support

Thickness of sticker Keyboard

Label

Page 57: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

6-3

INCORRECT insertion which could cause compromised adhesion:

The labels illustrated generate pressure that over time could cause the keyboard to scollare.

• The oversize part of the label must go under the back cover or in the appropriate fixing points (the choice is determined by the type of VTCE being used).

Compromised adhesion

Compromised adhesion

Back cover

Fixing points for adhesives

Page 58: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 6Inserting customized labels

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

6-4

Notes Here are some tips to make it easier to insert the label:

• Round off the corners.

• If there seems to be some resistance pull the label out and reinsert it.• If more than one label is used, insert them all at the same time.

Take care not to exceed the total thickness permitted (see Page 6-2 -> Label).

• Do not bend the label at right angles and/or do not bend them so sharply that they might be damaged.

• Slightly bend the label lengthwise to make it stiffer.

Label 1 Label 2

Index finger Thumb

Middle finger

Index finger Thumb

Middle finger

Page 59: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

7-1

Chapter 7 Mounting the terminal within the container

Contents Page

Using nuts 7-2

This chapter consists of 2 pages.

Page 60: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 7Mounting the terminal within the container

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

7-2

The VTCE comes supplied with the elements necessary for mounting it within the host container and fixing the sealing gasket giving the declared level of IP protection.

Using nuts The figure below shows the front and back views of a VTCE inserted in a container. Under the figure is to be found the sequence of operations to be carried out to ensure that the fixing is correct.

After preparing the container that will host the VTCE:

• Insert the VTCE in the cut-out• Hold the VTCE against the wall• Insert first the washer then the nut into the fastener• Tighten the nuts till the gasket has a firm grip

The number and position of the hooks do not influence the fixing procedure. The illustrations are to show the way the hooks work.

Cut-out of acontainer

Video Terminal NutWasher

Pre-applied gasketStud

Page 61: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-1

Chapter 8 Communication ports

Contents Page

General notes 8-2

COM1 serial port 8-3

LPT parallel port 8-4

Mouse PS/2 port 8-5

Keyboard PS/2 port 8-6

Ethernet network port 8-7

USB serial port 8-8

MSP, ASP and CAN serial ports 8-9

This chapter consists of 10 pages.

Page 62: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 8Communication ports

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-2

All VTCEs communicate with other devices by means of serial and/or par-allel communication ports. We list on the following page the individual ports with the respective type of communication and the function of the connection pins.

General notes Serial communication is particularly prone to disturbances. To limit the influ-ence of these disturbances it is necessary to use good quality shielded cables.

The table immediately below lists the characteristics of the cable we recom-mend for serial connection.

Particular care should be taken in the choice and lay-out of cables, specially with regard to the VTCE <-> Device connection serial cable.

Always:• Find the shortest route• Lay disturbed cables separately

Disconnect the power supply before connecting or disconnecting the communication cables so as to avoid possible damage to the

VTCE and/or the connected device.

Specifications of serial connection cableDirect current resistance Max. 151 Ohm/Km

Capacity coupling Max. 29pF/m

Shielding > 80% or total

Page 63: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-3

COM1 serial port

The COM1 serial port consists of a D-Sub 9 pin male connector and can communicate using RS232.

Pin Signal Notes1 DCD1 IN --2 RX1 IN --

3 TX1 OUT --

4 DTR1 OUT --5 Signal GND Internal reference 0Volt

6 DSR1 IN --

7 RTS1 OUT --8 CTS1 IN --

9 RI1 IN --

COM1Standar Serial Port

9 pin male

Page 64: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 8Communication ports

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-4

LPT parallel port

The LPT parallel port consists of a D-Sub 25 pin female connector. It is used to connect directly with the printer.

Pin Signal Notes1 BSTRB STROBE Centronics

2 BPD0 D0 Centronics

3 BPD1 D1 Centronics

4 BPD2 D2 Centronics5 BPD3 D3 Centronics

6 BPD4 D4 Centronics

7 BPD5 D5 Centronics8 BPD6 D6 Centronics

9 BPD7 D7 Centronics

10 BACK ACK Centronics11 BBUSY BUSY Centronics

12 BPE PE Centronics

13 BSLCT SLCT Centronics14 BAFDT AFDT Centronics

15 BERROR ERROR Centronics

16 BINIT INIT Centronics17 BSLCTIN SLCTIN Centronics

18 GND Internal reference 0Volt

19 GND Internal reference 0Volt20 GND Internal reference 0Volt

21 GND Internal reference 0Volt

22 GND Internal reference 0Volt23 GND Internal reference 0Volt

24 GND Internal reference 0Volt

25 GND Internal reference 0Volt

LPT25 pin female

Page 65: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-5

Mouse PS/2 port

The mouse PS/2 serial port consists of a Minidin 6 pin female connector and is used to connect a mouse.

Pin 4 does not provide for commuting any kind of load (coils etc.); an input disturbance at Pin 4 can cause the VTCE and therefore also

the industrial process itself to malfunction.

Strong input disturbances at Pin 4 could damage the VTCE.

Pin Signal Notes1 MSDATA Input/output open collector2 N.C. Not connected

3 Signal GND Internal reference 0Volt

4 PS2VCC Output with overload protection (Max 1A)5 MSCLK Input/output open collector

6 N.C. Not connected

MousePS/2

6 pin female

Page 66: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 8Communication ports

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-6

Keyboard PS/2 port

The mouse PS/2 serial port consists of a Minidin 6 pin female connector and is used to connect a keyboard.

Pin 4 does not provide for commuting any kind of load (coils etc.); an input disturbance at Pin 4 can cause the VTCE and therefore also

the industrial process itself to malfunction.

Strong input disturbances at Pin 4 could damage the VTCE.

Pin Signal Notes1 TPDATA Input/output open collector2 N.C. Not connected

3 Signal GND Internal reference 0Volt

4 PS2VCC Output with overload protection (Max 1A)5 TPCLK Input/output open collector

6 N.C. Not connected

KeyboardPS/2

6 pin female

Page 67: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-7

Ethernet network port

The Ethernet network port is made up of a RJ45 8 pin female connector and is dedicated to network connection with other terminals, with PCs and any other device that supports this standard.

Pin Signal Notes1 TX+ --

2 TX- --

3 RX+ --4 -- Reclosing with pin 5 and 75 ohm termination

5 -- Reclosing with pin 4 and 75 ohm termination

6 RX- --7 -- Reclosing with pin 8 and 75 ohm termination

8 -- Reclosing with pin 7 and 75 ohm termination

EthernetRJ45

8 pin female

Page 68: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 8Communication ports

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-8

USB serial port

The USB serial port is made up of a 4 pin connector and is dedicated to connection with any other device that supports this standard.

Pin Signal Notes1 USBVCC Output with overload protection (Max 1A)2 USBD- --

3 USBD+ --

4 Signal GND Internal reference 0Volt

USB4 pin male

Page 69: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

8-9

MSP, ASP and CAN serial ports

Serial port on the CIB communication board (optional). The VTCE termi-nal can be acquired with the board already inserted, otherwise the board may be acquired and then inserted later. For information on the board’s working, on its technical characteristics and on how to connect it, see the CIB board’s own manual.

Page 70: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 71: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-1

Chapter 9 VTCE video terminal accessories

Contents Page

Adapter PC 25F <-> VTCE 9M 9-3

Cell battery 9-4

Ethernet crossover cable 9-5

Null modem cable PC 25F <-> VTCE 9F 9-6

Null modem cable PC 9F <-> VTCE9F 9-7

Protfilm10/12 9-8

CIB board - MSP, ASP 9-10

CIB board - MSP, CAN 9-11

This chapter consists of 12 pages.

Page 72: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 9VTCE video terminal accessories

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-2

The video terminals are made to take a series of accessories that increase their capacity and/or functionality. This chapter shows how these accesso-ries relate to the various products. The table below shows which terminals will take which accessories.

Table 9.1: Accessories connectable to VTCE terminals

ACCESSORIESTERMINALS SUPPORTING THE ACCESSORY

VT330CE VT585CE VT595CE

Adapter PC 25 pin female -> 9 pin male ● ● ●

Lithium button cell battery 3V CR2032 ●1 ●1 ●1

Ethernet crossover cable ● ● ●

Null modem cablePC 25 pin female <-> VTCE 9 pin female

● ● ●

Null modem cablePC 9 pin female <-> VTCE 9 pin female

● ● ●

Protfilm10 -- ● --

Protfilm12 -- -- ●

CIB communication board with MSP and ASP port (only for VTxxxCE 0T000)

● ● ●

CIB communication board with MSP and CAN port (only for VTxxxCE 0T000)

● ● ●

Notes:1 - Already present on purchase

-- : not connectable

Page 73: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-3

Adapter PC 25F <-> VTCE 9M

With the adapter shown below a 25 pin PC can be connected to a VTCE using the same cable as that used for the 9 pin PC connection.

The table shows how to combine adaptors and cables connection to the var-ious ports.

Table 9.2: Combination of serial transfer + adapters

PC serial VTCE serialCable Adaptor

CVCOM41102

CVCOM41202

CVCOM25F9M

9 pins COM1 ● -- --

25 pins COM1 -- ● --

25 pins COM1 ● -- ●

CVCOM25F9M

PC sideAdaptor

from 9 to 25 pins

CVCOM25F9M

Page 74: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 9VTCE video terminal accessories

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-4

Cell battery The function of the battery is to keep the internal clock, the calibration of the Touch Screen (in the case of terminals that have one) and the setting of the address of the network’s IP when there is no power supply.

The battery should be replaced about every 36 months.

• The battery needs to be changed either when the Battery LED (on the VT keyboard) comes on. Failure to change the battery will lead to the con-tents of the data memory being lost.

In the case of products with a Touch Screen, the running down and/or absence of the battery is not indicated on the screen.

• The battery must be substituted with the VT power off.

Discarded batteries should be placed in appropriate containers.

Procedure for inserting or substituting the battery:

• Check that the power supply is not connected.• Take off the hatch covering the battery compartment of the VT.• Insert the new battery checking that the polarities are correct.• Replace the hatch covering the battery compartment of the VT.• Reconnect the power supply.

Battery to be used

Lithium 3V cell battery CR2032

Page 75: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-5

Ethernet crossover cable

The scheme below shows an Ethernet network crossover cable, which should be used for directly connecting the PC to the VTCE without using the company network connection.

12345678

1

3

2

6

Tx+

Rx+

Tx-

Rx-

1

3

6

2

Tx+

Rx+

Rx-

Tx-

12345678

PC SideRJ45 8 pin

VTCE SideRJ45 8 pinCVNET11002

FrontView

FrontView

Page 76: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 9VTCE video terminal accessories

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-6

Null modem cable PC 25F <-> VTCE 9F

The diagram below shows a serial cable of the Null modem type to be used when directly connecting the PC and the VTCE. Generally the connection is required when installing application packages in the terminal or for dis-playing the resources of the terminal directly on the PC.

2

3

7

6

8

Tx

Rx

GND

DSR

DCD

2

3

5

Rx

Tx

GND

5

20

CTS

DTR

4RTS 8

7

CTS

RTS

6

1

DSR

DCD

4 DTR

PC Side25 pin female

VTCE Side9 pin female

Max. 15 m.

CVCOM41202

Page 77: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-7

Null modem cable PC 9F <-> VTCE9F

The diagram below shows a serial cable of the Null modem type to be used when directly connecting the PC and the VTCE. Generally the connection is required when installing application packages in the terminal or for dis-playing the resources of the terminal directly on the PC.

3

2

5

6

1

Tx

Rx

GND

DSR

DCD

2

3

5

Rx

Tx

GND

8

4

CTS

DTR

7RTS 8

7

CTS

RTS

6

1

DSR

DCD

4 DTR

PC Side9 pin female

VTCE Side9 pin female

Max. 15 m.

CVCOM41102

Page 78: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 9VTCE video terminal accessories

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-8

Protfilm10/12

This is a transparent protective film to be applied to the front of the touch screen terminal to protect it from wear on the part of external agents (see “Chapter 12 -> Resistance to chemical substances“).

Applying the film:

How to apply the adhesive film:

• Remove any trace of dirt or grease from the terminal using denaturized ethyl alcohol

• Dry the area thoroughly• Locate the adhesive part of the transparent film

• Position the film near the upper edge and smooth it down delicately

279.0

206.0

250.0

187.0

PROTFILM10 PROTFILM12

Page 79: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-9

• Pass a soft cloth firmly over the edges to ensure adhesion

How to remove the adhesive film:

• To remove the film, pull upwards using the tab

Page 80: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 9VTCE video terminal accessories

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-10

CIB board - MSP, ASP

This is a communication board with a PC104 format which adds MSP and ASP ports which enable communication with all devices supported by ESA. For information on the board’s working, on its technical characteris-tics and on how to connect it, see the CIB board’s own manual.

Page 81: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

9-11

CIB board - MSP, CAN

This is a communication board with a PC104 format which adds MSP and CAN ports which enable communication with all devices supported by ESA. For information on the board’s working, on its technical characteris-tics and on how to connect it, see the CIB board’s own manual..

Page 82: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 83: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

10-1

Chapter 10 Basic concepts

Contents Page

RAM 10-2

Flash Disk 10-2

Storage Card 10-2

Saving the Registry 10-2

This chapter consists of 4 pages.

Page 84: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 10Basic concepts

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

10-2

This chapter limits itself to introducing some simple but basic concepts to help first-time users of VTCE terminals.

Windows® CE is a standard operating system and as such none of its operational procedures and concepts have been determined by

ESA elettronica.

RAM The RAM memory is used by the system to run programs, calculations and whatever else is needed for the system to operate properly; furthermore, it is used for saving (whether manually or following the installation of an application package) all files loaded by the user.

The RAM memory is not buffered by a battery.

When the terminal is switched off all the information it contains is can-celled, including the files and programs. If it is necessary to keep the files after switching off, these must be moved to/put in a Flash Disk.

Flash Disk VTCE terminals have no hard disk but rather use a flash disk and handle this like a solid state hard disk. The files that have been loaded or the appli-cation packages that have to be kept permanently even after switching off the terminal must be placed in the folder My Computer\FlashDisk in the main root or in a sub-folder.

The FlashDisk is managed so as to guarantee the security of the data; this means that even when there is no power, the data being written at that moment will be saved.

Storage Card This is an external device (the PCMCIA is card not supplied by ESA, its supply is the responsibility of the user) that is inserted in the terminal and is used to increase the capacity of its (permanent) memory. Once the card has been inserted the system will automatically display a system folder called My Computer\Storage Card. The files that have been loaded or the applica-tion packages that have to be kept permanently even after switching off the terminal can be placed in the folder in the main root or in a sub-folder.

The card can be inserted without switching the terminal off.

Saving the Registry

As indicated earlier, the VTCE terminal uses non-permanent memory, thus, with the exception of the initial settings given by ESA, all the settings are lost when the terminal is switched off.

Page 85: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

10-3

The saving of the configuration register (Registry) enables the settings to be saved in the permanent memory area.

The configuration register must be saved every time there is a change of parameters, for example, following a network setting, a remote connection or the installation of an application, etc.

You are advised to carry out a “save” after each installation or each time settings are changed.

To activate this function, click on Start > Programs >

Windows Explorer or double-click on (My Computer) on the Desktop

of the terminal. Double-click on Windows, then double-click on

(Regedit). Alternatively double-click on (Regedit) on the Desktop of the terminal.

Once the saving phase has finished click on to close the window.

The saving procedure may require a few seconds.

Click on the Write.

Page 86: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 87: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-1

Chapter 11 Using the system

Contents Page

Calibrating the Touch Screen 11-2

Enabling communication with remote terminals 11-3

Direct PC / VTCE connection using Ethernet 11-4

Connection in Ethernet 11-10

PC / VTCE connection using serial port 11-14

Automatic execution of applications 11-19

Managing the Fonts 11-21

This chapter consists of 22 pages.

Page 88: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-2

Calibrating the Touch Screen

The VT5xxCE terminal is supplied already calibrated and operational; should it be thought necessary to repeat the calibration procedure, this can be done using the appropriate software function or it is so far out that the function cannot be activated, the calibration can be forced by using a hard-ware jumper (see Page 4-9 or Page 5-9).

To activate the function click on Start > Settings > Control Panel, then

double-click on (Stylus).

Then follow the instructions on screen. Once the calibration has been com-

pleted click on to accept the changes and close the window.

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Then browse the to click on Calibration.

Click on the Recalibrate.

Page 89: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-3

Enabling com-munication with remote terminals

To make it possible for the terminal to be connected to a PC or a remote ter-minal it is necessary to assign a name that identifies it unambiguously. The terminal is supplied with a name defined by ESA but this has to be changed for it to work properly.

To activate the function click on the Start > Settings > Control Panel,

then double-click on (Communic..).

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Enter the required name in the Device Name field.

Assign the description too, entering it in the Device Description field.

Click on the OK to accept the changes and close the window.

Page 90: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-4

Direct PC / VTCE connec-tion using Ethernet

This type of connection makes it possible for the PC and VTCE to exchange files simply and rapidly using Windows Explorer on the CE ter-minal. The connection utilizes the Server and Client mechanism, so it is necessary for the PC (which becomes the Server) to share its folder or fold-ers to be put at the disposal of the VTCE terminal (which becomes the Cli-ent).

For more on the folder sharing procedure see the on-line manual of the operative system installed.

The direct connection must be made by means of a crossover Ethernet net-work cable (for details on the cable see “Chapter 9 -> VTCE video terminal accessories“).

Once the physical connection has been made proceed to set the parameters as follows.

CVNET11102

You are advised to carry out all connection and disconnection oper-ations with the VTCE off.

Page 91: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-5

Assigning the network address to the VTCE:

Once the logical connection has been established go to the VTCE terminal and click on the Start > Settings > Control Panel and then double-click

on (Network).

The first three numbers of the IP address assigned must be the same as those of the PC with which the connection is to be made,

the fourth number must be different (example: PC - 192.168.100.1, VTCE - 192.168.100.5).

Click on to accept the changes.

Select as in the figure and click on the Properties.

Set as in the figure.

Then enter the network address in the IP Address field.

Click on the OK.

Page 92: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-6

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Skip setting the Identification as it is irrelevant in this phase.

Click on the OK.

Page 93: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-7

Testing the connection:

If required you can test whether the system is operating properly by running the command PING on the PC.

Go to the PC’s command prompt and digit ping followed by the IP address assigned to the VTCE and then confirm by pressing the Enter key (e.g. ping 192.168.100.5).

If the connections and settings have been made correctly, response strings will appear containing the IP address requested; contrariwise, if expired request strings appear, this means that there are connection problems; in this case look over the entire procedure including the connection cable.

Page 94: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-8

Exploring the PC:

Go to the VTCE and click on the Start > Programs > Windows Explorer

or double-click on (My Computer) on the Desktop of the terminal.

Go to the Address field, digit the name of the computer connected (e.g. \\PC).

Confirm with Enter.

The first time you try the connection, if no password has been assigned, a mask appears in which a password can be entered. If one is necessary, assign it, if not, do not compile the mask.

Click on the OK.

Page 95: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-9

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Answer YES or NO depending on your requirements.

The folder shared with the server PC is displayed.

Page 96: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-10

Connection in Ethernet

This allows the VTCE to be integrated within the company network. Once the connection has been made, the device behaves in practice like a PC except that it cannot itself put folders at the disposal of other network par-ticipants.

The physical connection must be made using a standard Ethernet network cable.

Once the physical connection has been made, the parameters can be set as follows.

Ethernet

Page 97: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-11

Assigning the network address to a VTCE:

Once the logical connection has been established go to the VTCE terminal and click on the Start > Settings > Control Panel and then double-click

on (Network).

NOTE: As all parameters that are to be entered in the masks that appear below depend on the configuration of the network with

which you wish to be connected, they may be different from those given as examples in the figure. You are therefore advised to contact the net-work administrator.

Select as illustrated and click on the Properties.

Set as in the figure (see note).

Then browse the and click on Name Servers.

Set as in the figure (see note).

Click on the OK.

Page 98: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-12

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Testing the connection:

See Pag. 11-7 -> “Testing the connection:“

Click on the OK.

Browse the and click on Identification.

Set as in the figure (see note).

Click on the OK.

Page 99: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-13

Exploring the network:

Go to the VTCE and click on the Start > Programs > Windows Explorer

or double-click on (My Computer) on the Desktop of the terminal.

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Go to the Address field and enter the name of the network server (e.g. \\PC).

Confirm with Enter.

The folders available in the network are displayed.

Page 100: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-14

PC / VTCE connection using serial port

If this software interface (Microsoft Active Sync) is installed a PC can treat a connected VTCE terminal as if it were a resource of the PC itself.

The program can be freely downloaded from the Internet using the follow-ing address:

http://www.microsoft.com/downloads/search.asp

The connection must be made using a Null Modem serial cable (for details regarding the cable see “Chapter 9 -> VTCE video terminal accessories“).

Once the physical connection has been made, the parameters can be set as follows.

CVCOM25F9M

CVCOM41102

CVCOM25F9Mor

CVCOM41202

You are advised to carry out all connection and disconnection oper-ations with the VTCE off.

Page 101: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-15

Creating a remote connection on the VTCE:

Go to the VTCE and click on the Start > Programs > Windows Explorer

or double-click on (My Computer) on the Desktop of the terminal. Dou-

ble-click on the Windows, then double-click on (Remnet) and finally

double-click on (Make New Connection).

The Baud Rate value must be set at a value above 38400 otherwise the connection may not work properly.

Enter the name to be assigned to the connection.

Select as in the figure and click on the Next.

Select as in the figure and click on the Configure.

Enter the desired Baud Rate value.

Set the other parameters as in the figure.

Skip the settings for the Call Options, they are irrelevant at this stage.

Click on the OK.

Page 102: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-16

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Skip the settings for TCP/IP Settings, they are irrelevant at this stage.

Click on the Finish.

Page 103: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-17

Assigning a remote connection on the VTCE:

To activate the function click on the Start > Settings > Control Panel

then double-click on (Communic..).

Click on to accept the changes and close the window.

Proceed to save the configuration register if you want the settings to be made permanent (see “Chapter 10 -> Saving the Registry“).

Browse the and click on PC Connection.

Set as shown in the figure.

Click on the Change.

Set as shown in the figure.

Click on the OK.

Page 104: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-18

Making the connection between PC and VTCE:

Install Active Sync (by following the instructions on-screen) on the PC to be connected to the VTCE.

Even if there is no explicit request when the installation is over we advise you to disconnect the serial cable and restart the PC; once

it has restarted, reconnect the serial cable and try connecting with the VTCE terminal.

Once the installation has finished, and after setting the communication parameters on the PC, establish the connection.

While the program is searching for the logical connection, go to the VTCE and click on the Start > Programs > Windows Explorer or double-click

on (My Computer) on the Desktop of the terminal. Double-click on the

Windows, then double-click on (Replog). A connection window is displayed which then closes automatically when the connection is estab-lished.

The PC displays the request “establish a relationship”, answer NO and click the Next; the terminal is seen by the PC as a “Guest”, at this point close the window that is being displayed.

The VTCE is recognized by the PC by means of “Explore Resources” as “Portable device”: files can be transferred and installations carried out on the VTCE terminal.

The connection can only be made using COM, other communica-tion ports (USB, Ethernet, etc.) cannot be used and so we advise

you to deactivate them.

Page 105: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-19

Automatic execution of applications

When in the start phase VTCE terminal calls for an automatic execution procedure for the applications.

To do this create a on the VTCE terminal; this must be called Flash-Disk\ESA\Startup.

The name and path of the folder MUST be precisely as set out above, otherwise the files will not be found.

To create the new folder click on Start > Programs > Windows Explorer

or double click on (My Computer) on the Desktop of the terminal. Dou-ble click on the FlashDisk then click on File > New Folder.

Once the above-mentioned folder has been created you can proceed in two ways:

• Load .EXE file

Just copy the .exe file of the application directly into the previously created . To copy or move the files, see, if necessary Pag. 11-4 -> “Direct PC / VTCE connection using Ethernet“ or Pag. 11-10 -> “Connection in Ethernet“ or Pag. 11-14 -> “PC / VTCE connection using serial port“.

• The .ESA file is created and loaded

Should it be possible directly to use the executable file, proceed by creating a text file called Startup.esa putting into it the complete path of where the execurable file can be found and , if necessary, the parameters requested by the .exe file. Only one executable file is required for every row.

Example.

\FlashDisk\Demo\Demo.exe \FlashDisk\Demo\Project.prj\FlashDisk\Myfolder\Myfile.exe

The name of the file MUST be Startup.esa otherwise it will not be found.

Only invocations for .EXE files and any parameters can be added.

If the file is edited outside the VTCE terminal, it must be saved as “Unicode text document”.

Page 106: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 11Using the system

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-20

To see this folder click on the Start > Programs > Windows Explorer or

double-click on (My Computer) on the Desktop of the terminal. Dou-ble-click on the FlashDisk and then double-click on the Esa. Finally double-click on the Startup.

If there is more than one file in the Startup folder, these will be executed in the order: first the .EXE files and then the .ESA ones.

Page 107: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

11-21

Managing the Fonts

The VTCE terminal is supplied with a series of font already installed. If the user so desires, other fonts of the “True Type” type can be loaded.

To do this, create a on the VTCE terminal and call it Flash-Disk\ESA\Fonts.

The name of the folder and the path MUST be exactly as set out above, otherwise new fonts will not be found.

To create the new folder click on Start > Programs > Windows Explorer

or double click on (My Computer) on the Desktop of the terminal. Dou-ble click on the FlashDisk then click on File > New Folder.

At this point, all that needs to be done is choose from among the fonts loa-ded on a normal PC and copy them onto VTCE into the previously created

. To copy or move the files, see, if necessary Pag. 11-4 -> “Direct PC / VTCE connection using Ethernet“ or Pag. 11-10 -> “Connection in Ether-net“ or Pag. 11-14 -> “PC / VTCE connection using serial port“.

To see this folder click on the Start > Programs > Windows Explorer or

double-click on (My Computer) on the Desktop of the terminal. Dou-ble-click on the FlashDisk and then double-click on the Esa. Finally double-click on the Fonts.

Page 108: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 109: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-1

Chapter 12 Resistance to chemical substances

Contents Page

Chemical substances 12-2

Cleaning the VTCE 12-7

This chapter consists of 8 pages.

Page 110: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 12Resistance to chemical substances

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-2

All our VTCEs are built to withstand the effects of the more common chemical substances encountered in industrial and non-industrial environ-ments. Each element of the VTCE that could be exposed to these sub-stances (epoxy coating, keyboard membrane, screen surface, touch screen and gaskets), is tested to determine its degree of resistence.

The type of test is not the same for each component but changes according to the testing authority. Below is an example of a test (carried out by Alca-tel Bell).

The test procedure was as follows:

A 2 cm ball of cotton wool was immersed in the test substance and then placed on the keyboard. Two cotton wool balls with different substances were placed separately on each keyboard; this was then put in a Petri dish and kept at a temperature of 25°C for an hour; after this, the keyboard was washed in water and dried.

The keyboard was observed and the results classified as follows:• A - No visible deterioration• B - Very slight deterioration• C - Some deterioration• D - Gross damage visible

The substances not appearing in the table were not tested, so there is no information regarding their effect.

Chemical substances

The table shown below lists all the substances used for the test with their various results.

The table must nevertheless be considered an approximate guide regard chemical substances: no tests have been carried out on a

completely assembled terminal.

Page 111: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-3

Table 12.1: Chemical resistance data sheet (Part 1 of 5)

Substance

Parts of the VTCE Accessories

Resis-tance

Epoxypowder

coating 3

Mattkeyboard surface 2

Transpar-ent key-board

surface 1

Touch screen 2

Protective-glass Gaskets Protective 2

film

1,1,1-Trichlorethylene NS -- >24h -- >24h -- -- >24h ☺Acetaldehyde NS -- >24h -- >24h -- -- >24h ☺

Acetic acid

10% 3Y -- -- -- -- -- -- ☺20% 3Y -- -- -- -- -- -- ☺

<50% -- >24h -- >24h -- -- >24h ☺Acetone NS O >24h -- >24h >8h F >24h "Acetyl NS -- -- -- -- -- E -- "

Acid solutionsLC -- -- -- -- -- E -- ☺HC -- -- -- -- -- F -- "

Ajax NS -- >24h4 -- >24h4 -- -- -- ☺Aliphatic hydrocarbons NS -- >24h -- >24h -- -- >24h ☺

Alkaline solutionsLC -- -- -- -- -- E -- ☺HC -- -- -- -- -- F -- "

Ammonia

NS -- -- -- -- -- E -- ☺<2% -- >24h -- >24h -- -- >24h ☺5% -- -- -- -- >24h -- -- ☺

10% 3Y -- -- -- -- -- -- ☺35% 3Y -- -- -- -- -- -- ☺

Ariel NS -- >24h4 -- >24h4 -- -- -- ☺Benzene NS S -- A >24h -- -- >24h "Benzylalcohol NS -- O -- O -- -- O #Bichromate NS -- -- -- >24h -- -- >24h ☺Blown castor oil NS -- -- -- >24h -- -- -- ☺Carbon dioxide NS -- -- -- -- -- E -- ☺Castor oil NS -- >24h -- >24h -- -- >24h ☺

Caustic soda

<2% -- >24h -- >24h -- -- >24h ☺10% -- -- -- -- >24h -- -- ☺50% -- -- B -- -- -- -- "

Caustic solution CO -- O -- O -- -- O #Chloric acid NS -- -- A -- -- -- -- ☺Chlorine NS -- -- -- -- -- G -- #Legend:A - No visible degradation, B - Very slight degradation, C - Slight degradation, D - Damage visible or gross, E - Unlimited use, F - Limitated use, G - Use inad-visable, S - The surface melts, X - The surface blisters, O - The surface is destroyed, CO - Concentrated, HC - High concentration, LC - Low concentration, SA - Saturated, NS - Not specified, h - Hour(s), M - Month(s), Y- Year(s), ☺ - All the elements tested resist all the substances, " - At least one of the ele-ments tested may be damaged by the substances in question, # - All the elements tested may be damaged by the substances in question, -- Not tested.

Notes:1 - According to Alcatel Bell tests, 2 - According to DIN42115 Parts 2, 3 standards - According to raw material producers, 4 - Tested at 50°C

Page 112: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 12Resistance to chemical substances

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-4

Chromic acid10% 6M -- -- -- -- -- -- "20% 6M -- -- -- -- -- -- "

Citric acid 5% 3Y -- -- -- -- -- -- ☺Coca Cola NS -- -- A -- -- -- -- ☺Cooking salt solution NS -- -- -- -- -- E -- ☺Copper sulphate 10% 3Y -- -- -- -- -- -- ☺Crude oil NS 3Y -- -- -- -- -- -- ☺Cutting oil NS -- >24h -- >24h -- -- >24h ☺Cyclohexanol NS -- >24h -- >24h -- -- >24h ☺Detergent NS -- -- A -- -- -- -- ☺Diesel fuel NS -- >24h A >24h -- -- >24h ☺Diethyle ether NS -- >24h -- >24h -- -- >24h ☺Dioxan NS -- >24h -- >24h -- -- >24h ☺Domestos NS -- >24h4 -- >24h4 -- -- -- ☺Downey NS -- >24h4 -- >24h4 -- -- -- ☺Edible oil NS 3Y -- -- -- -- -- -- ☺Essence of turpentine substitute NS 3Y -- -- -- -- -- -- ☺

EthanolNS -- -- A >24h >24h E >24h ☺

96% 3Y -- -- -- -- -- -- ☺Ethanol denat. NS 1M -- -- -- -- -- -- "Ethylacetate NS -- >24h -- >24h -- -- >24h ☺Ethylene glycol NS O -- A -- -- -- -- "Fantastic NS -- >24h4 -- >24h4 -- -- -- ☺

Formaldehyde

NS -- -- A -- -- -- -- ☺35Vol. 3Y -- -- -- -- -- -- ☺37% -- >24h -- -- -- -- -- ☺42% -- >24h -- -- -- -- -- ☺

Formic acid

5% 3Y -- -- -- -- -- -- ☺10% 3Y -- -- -- -- -- -- ☺

<50% -- >24h -- >24h -- -- >24h ☺Formula 409 NS -- >24h4 -- >24h4 -- -- -- ☺Gasoline/petrol NS 3Y -- A >24h >24h F >24h "Glacial acetic acid NS -- -- -- <1h -- -- <1h "

Table 12.1: Chemical resistance data sheet (Part 2 of 5)

Substance

Parts of the VTCE Accessories

Resis-tance

Epoxypowder

coating 3

Mattkeyboard surface 2

Transpar-ent key-board

surface 1

Touch screen 2

Protective-glass Gaskets Protective 2

film

Legend:A - No visible degradation, B - Very slight degradation, C - Slight degradation, D - Damage visible or gross, E - Unlimited use, F - Limitated use, G - Use inad-visable, S - The surface melts, X - The surface blisters, O - The surface is destroyed, CO - Concentrated, HC - High concentration, LC - Low concentration, SA - Saturated, NS - Not specified, h - Hour(s), M - Month(s), Y- Year(s), ☺ - All the elements tested resist all the substances, " - At least one of the ele-ments tested may be damaged by the substances in question, # - All the elements tested may be damaged by the substances in question, -- Not tested.

Notes:1 - According to Alcatel Bell tests, 2 - According to DIN42115 Parts 2, 3 standards - According to raw material producers, 4 - Tested at 50°C

Page 113: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-5

Glycerine NS -- >24h -- >24h -- E >24h ☺Glycol NS -- -- -- -- -- E -- ☺Grape juice NS -- >24h4 -- >24h4 -- -- -- ☺Gumption NS -- >24h4 -- >24h4 -- -- -- ☺High pressure steam (at >100°C) NS -- O -- O -- G O #Hydraulic fluids NS -- -- -- -- -- F -- "

Hydrochloric acid

<10% -- >24h -- >24h -- G >24h "10% 3Y -- -- -- -- -- -- ☺20% 3Y -- -- -- -- -- -- ☺

Hydrogen peroxide

<25% -- -- -- >24h -- -- >24h ☺30% -- -- A -- -- -- -- ☺

40Vol. 6M -- -- -- -- -- -- "Isopropanol NS S >24h A >24h -- -- >24h "Jet Dry NS -- >24h4 -- >24h4 -- -- -- ☺Lactic acid 5% 3Y -- -- -- -- -- -- ☺Lemon juice NS -- B4 -- B4 -- -- -- "Lenor NS -- >24h4 -- >24h4 -- -- >24h ☺Linseed oil NS 3Y >24h -- >24h -- -- >24h ☺Liquid allum NS -- -- -- -- -- E -- ☺Methane NS -- -- -- -- -- F >24h "Methanol NS -- >24h A >24h -- F -- "Methyl ethyl ketone NS -- >24h -- >24h -- -- >24h ☺Methylene Chloride NS 1M O -- O -- G O #Milk NS -- >24h4 -- >24h4 -- -- -- ☺Mineral acids CO -- O -- O -- -- O #Mineral oil 0-180 NS -- -- A -- -- E -- ☺Mustard NS -- >24h4 -- >24h4 -- -- -- ☺n-Butanol NS S -- -- -- -- -- -- "Nitrate of ammonia SA 3Y -- -- -- -- -- -- ☺

Nitric acid

<10% -- >24h D >24h -- G >24h "10% 3Y -- -- -- -- -- -- ☺20% 3Y -- -- -- -- -- -- ☺50% 1M -- -- -- -- -- -- "

Table 12.1: Chemical resistance data sheet (Part 3 of 5)

Substance

Parts of the VTCE Accessories

Resis-tance

Epoxypowder

coating 3

Mattkeyboard surface 2

Transpar-ent key-board

surface 1

Touch screen 2

Protective-glass Gaskets Protective 2

film

Legend:A - No visible degradation, B - Very slight degradation, C - Slight degradation, D - Damage visible or gross, E - Unlimited use, F - Limitated use, G - Use inad-visable, S - The surface melts, X - The surface blisters, O - The surface is destroyed, CO - Concentrated, HC - High concentration, LC - Low concentration, SA - Saturated, NS - Not specified, h - Hour(s), M - Month(s), Y- Year(s), ☺ - All the elements tested resist all the substances, " - At least one of the ele-ments tested may be damaged by the substances in question, # - All the elements tested may be damaged by the substances in question, -- Not tested.

Notes:1 - According to Alcatel Bell tests, 2 - According to DIN42115 Parts 2, 3 standards - According to raw material producers, 4 - Tested at 50°C

Page 114: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 12Resistance to chemical substances

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-6

Nitrocellulose solvents NS -- -- -- -- -- G -- #Oil NS -- -- -- -- -- E -- ☺Oleic acid NS 3Y -- -- -- -- -- -- ☺Paraffin oil NS 3Y >24h -- >24h -- -- >24h ☺Perchloroethylene NS -- -- -- >24h -- G >24h "Persil NS -- >24h4 -- >24h4 -- -- -- ☺

Phosphoric acid

10% 3Y -- -- -- -- -- -- ☺20% 3Y -- -- -- -- -- -- ☺50% 3Y -- -- -- -- -- -- ☺

<30% -- >24h -- >24h -- -- >24h ☺Photographic chemicals NS -- -- -- -- -- E -- ☺Potassium carbonate NS -- >24h -- >24h -- -- >24h ☺Potassium ferrocyanide NS -- >24h -- >24h -- -- >24h ☺

Potassium hydroxide10% 3Y -- -- -- -- -- -- ☺20% 3Y -- -- -- -- -- -- ☺

Sea water NS -- -- -- -- -- E -- ☺Sebacic acid SA 3Y -- -- -- -- -- -- ☺Silicon grease NS -- -- -- -- -- E -- ☺Silicon oil NS -- -- -- >24h -- E >24h ☺Skydrol NS 6M -- -- -- -- -- -- "Sodium carbonate SA -- >24h -- -- -- -- -- ☺Sodium chloride 3% 3Y -- -- -- -- -- -- ☺Sodium hydroxide 20% 3Y -- -- -- -- -- -- ☺

Sodium hypochloride

NS -- >24h -- -- -- -- -- ☺10% 6M >24h -- -- -- -- -- "

<20% -- -- -- >24h -- -- >24h ☺Softner NS -- >24h -- >24h -- -- -- ☺

Sulphuric acid

<10% -- -- -- -- -- -- >24h ☺10% 3Y -- -- >24h >24h -- -- ☺28% 3Y -- A -- -- -- -- ☺50% 6M -- -- -- -- -- -- "CO -- -- -- -- -- G -- #

Tartaric acid SA 3Y -- -- -- -- -- -- ☺

Table 12.1: Chemical resistance data sheet (Part 4 of 5)

Substance

Parts of the VTCE Accessories

Resis-tance

Epoxypowder

coating 3

Mattkeyboard surface 2

Transpar-ent key-board

surface 1

Touch screen 2

Protective-glass Gaskets Protective 2

film

Legend:A - No visible degradation, B - Very slight degradation, C - Slight degradation, D - Damage visible or gross, E - Unlimited use, F - Limitated use, G - Use inad-visable, S - The surface melts, X - The surface blisters, O - The surface is destroyed, CO - Concentrated, HC - High concentration, LC - Low concentration, SA - Saturated, NS - Not specified, h - Hour(s), M - Month(s), Y- Year(s), ☺ - All the elements tested resist all the substances, " - At least one of the ele-ments tested may be damaged by the substances in question, # - All the elements tested may be damaged by the substances in question, -- Not tested.

Notes:1 - According to Alcatel Bell tests, 2 - According to DIN42115 Parts 2, 3 standards - According to raw material producers, 4 - Tested at 50°C

Page 115: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

12-7

Cleaning the VTCE

For cleaning the VTCE we recommend Denaturalised Ethyl Alcohol. Should this be insufficient for removing the impurity making it necessary to use other products, consult the tables above.

Teepol NS 3Y -- -- -- -- -- -- ☺Toluene NS 3Y >24h A >24h -- G >24h "Tomato juice NS -- B4 -- B4 -- -- -- "Tomato sauce NS -- B4 -- B4 -- -- -- "Top Job NS -- >24h4 -- >24h4 -- -- -- ☺Trichloroethylene NS S -- -- >24h -- G >24h "Turpentine oil NS -- >24h -- -- -- F -- "Turpentine substitute NS -- -- -- >24h -- -- >24h ☺Vaselline NS -- -- -- -- -- F -- "Vim NS -- >24h4 -- >24h4 -- -- -- ☺Vinegar NS -- -- D -- -- -- -- #Vortex NS -- >24h4 -- >24h4 -- -- -- ☺Washing powders NS -- >24h -- >24h -- E >24h ☺Water NS -- >24h -- -- -- E -- ☺White spirit NS 3Y -- A -- -- -- -- ☺Windex NS -- >24h4 -- >24h4 -- -- -- ☺Wisk NS -- >24h4 -- >24h4 -- -- -- ☺Wood oil NS -- -- -- -- -- F -- "Xilene NS 1Y >24h -- >24h -- -- -- ☺

Table 12.1: Chemical resistance data sheet (Part 5 of 5)

Substance

Parts of the VTCE Accessories

Resis-tance

Epoxypowder

coating 3

Mattkeyboard surface 2

Transpar-ent key-board

surface 1

Touch screen 2

Protective-glass Gaskets Protective 2

film

Legend:A - No visible degradation, B - Very slight degradation, C - Slight degradation, D - Damage visible or gross, E - Unlimited use, F - Limitated use, G - Use inad-visable, S - The surface melts, X - The surface blisters, O - The surface is destroyed, CO - Concentrated, HC - High concentration, LC - Low concentration, SA - Saturated, NS - Not specified, h - Hour(s), M - Month(s), Y- Year(s), ☺ - All the elements tested resist all the substances, " - At least one of the ele-ments tested may be damaged by the substances in question, # - All the elements tested may be damaged by the substances in question, -- Not tested.

Notes:1 - According to Alcatel Bell tests, 2 - According to DIN42115 Parts 2, 3 standards - According to raw material producers, 4 - Tested at 50°C

Page 116: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 117: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

13-1

Chapter 13 Software compatibility

Contents Page

Movicon 13-2

Zenon 13-3

This chapter consists of 4 pages.

Page 118: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 13Software compatibility

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

13-2

After carrying out tests with certain types of supervision software, ESA elettronica declares them to be completely compatible with all its VTCE terminals. Below is a list of the software types tested.

Movicon Producer:

Software:

Minimum HW requirements

For the software to work properly a PC needs to be configured as set out below.

Minor applications:

• Processor: PENTIUM 233Mhz• Operative system: Windows 98 / Me• RAM Memory: 32 Mbytes• Occupation HD: 100Mbytes or more

Medium and major applications:

• Processor: PENTIUM II 350Mhz• Operative system: Windows 98 / Me / 2000 / NT 4.00• RAM Memory: 64 Mbytes• Occupation HD: 100Mbytes or more

Compatibility with VTCE

For this product compatibility is guaranteed for all VTCE terminals with Windows CE 3.0 without the optional CIB board. The versions of the soft-ware must be as follows or later.

• Movicon 9.1, Build 604 of 25-09-2002• Movicon CE 3.0, Build 104 of 25-09-2002

For information on how to install the program and on how to create a project see “Chapter 14 -> Creating a project with Movicon“.

Page 119: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

13-3

Zenon Producer:

Software:

Recommended HW requirements

For the software to work properly a PC needs to be configured as set out below.

• Processor: PENTIUM PENTIUM II PENTIUM II• Operative system: Windows Me Windows NT 4.0 Windows 2000/XP• RAM Memory: 32 Mbytes 64 Mbytes 256 Mbytes• Occupation HD: 500Mbytes 500Mbytes 500Mbytes

Compatibility with VTCE

For this product compatibility is guaranteed for all VTCE terminals with Windows CE 3.0 with or without the optional CIB board. The versions of the software must be as follows or later.

• Zenon 5.50 SP3• Zenon CE 5.50 SP3

For information on how to install the program and on how to create a project see “Chapter 15 -> Creating a project with ZenOn“.

Page 120: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 121: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

14-1

Chapter 14 Creating a project with Movicon

Contents Page

Installation 14-2

The project 14-3

Transferring Movicon files to a VTCE 14-3

Transferring a project to a VTCE 14-4

This chapter consists of 6 pages.

Page 122: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 14Creating a project with Movicon

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

14-2

This chapter deals EXCLUSIVELY with the settings and procedures nec-essary for using a Movicon project in Windows CE.

A knowledge of Movicon is indispensable in order to be able to fol-low this chapter. Without this, it is better to turn to the documen-

tation coming from the producer or the Progea Technical Assistance.

Installation The installation procedure is divided in two parts: the first consists in the installation of the basic version of Movicon, after which the update Movi-con CE is installed, which allows you to create projects for VTCE terminals (see also “Chapter 13 -> Software compatibility“).

What is set out below may be modified by Progea at any point with ESA knowing, consequently the installation procedure

described here may include some imprecision as to details.

If problems of installation are encountered or clarifications regarding the installation procedure are required, it is better to

turn to the documentation coming from the producer or the Progea Technical Assistance.

Put the Cd-Rom into the appropriate drive; if the PC’s “automatic loading notification” has been activated, the Movicon presentation will start auto-matically, if not, click on Start > Run…

Digit e:\Setup.exe and confirm with OK.

If the drive to be used is not “e:”, digit the appropriate letter.

Follow the on-screen instructions.

It is recommended that “Normal Installation” be selected for the installation phase.

Devices sup-ported by Movicon

Serial COM1

Page 123: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

14-3

Once Movicon has been installed, proceed with the Movicon CE update.

Proceed as for the preceding point: if it does not start automatically click on Start > Run… and digit e:\Setup.exe then confirm with OK.

Start the installation following the on-screen instructions and taking care to set the following parameters as set out below:

• Select Device -> Handheld PC2000• Select Language -> As desidered• Select Components -> All (Recommended)• Select Communications -> All (Recommended)• Select Processor type -> Other processor (ARM, SHx, x86)

Close installation in line with the instructions.

If there is a serial cable connection between the PC and the VTCE and a connection has been established using Microsoft Active Sync (see “Chapter 11 -> Using the system“), Movicon will automatically install the files needed for handling the project. If this is not the case, the transfer to the VTCE can be carried out manually later (see Page 14-3 -> “Transferring Movicon files to a VTCE“).

The project A project can be created without having a VTCE available.

A knowledge of Movicon is indispensable in order to be able to fol-low this chapter. Without this, it is better to turn to the documen-

tation coming from the producer or the Progea Technical Assistance

Settings for projects for Windows CE

There are no special procedures and/or settings for creating a project work-ing on a VTCE terminal. You need only to keep in mind CE’s limitations. For a more detailed description, see Movicon’s on-line Guide.

Transferring Movicon files to a VTCE

The next step is to transfer all the files necessary for Movicon to handle the project on the VTCE terminal.

Before starting, check that there is a Serial connection between the PC and the VTCE (see “Chapter 11 -> Using the system“).

Use a serial cable connection and establish the connection by means of Microsoft Active Sync (see “Chapter 11 -> Using the sys-

tem“).

Click on Programs > MOVICON 9.1 > Movicon CE Installation >

Page 124: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 14Creating a project with Movicon

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

14-4

HPC2000 > MovCE English Installation.

The file transfer masks are displayed; follow the on-screen instructions.

Note:• The destination path depends on the type of support that is to take the

project:

• Hard disk -> \FlashDisk\My path\• PCMCIA -> \Storage Card\My path\

Other paths are possible, but when the VTCE terminal is switched off all the data is lost (see “Chapter 10 -> Basic con-

cepts“).

Sometimes, for reasons not attributable to ESA, the processor in the terminals is not recognized by Movicon. When this happens

contact the Progea Technical Assistance.

Transferring a project to a VTCE

Now the project is transferred.

Before starting, check that there is a Serial connection between the PC and the VTCE (see “Chapter 11 -> Using the system“).

Use a serial cable connection and establish the connection by means of Microsoft Active Sync (see “Chapter 11 -> Using the sys-

tem“).

Click on File > Export project for WinCE

Note:• The destination path depends on the type of support that is to take the

project:

• Hard disk -> \FlashDisk\My path\• PCMCIA -> \Storage Card\My path\

Other paths are possible, but when the VTCE terminal is

Select the desired.

Click on OK.

Page 125: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

14-5

switched off all the data is lost (see “Chapter 10 -> Basic con-cepts“).

• The final destination is the same as the source.

For example. Suppose we wish the transfer to be onto FlashDisk:

Path on PC -> C:\Programs\Progea\My projectPath on VTCE -> \FlashDisk\Programs\Progea\My project

To activate the project, double-click on the file MovCE.exe (see Page 14-3 -> “Transferring Movicon files to a VTCE“ for the path; a mask for choos-ing the project to be run is displayed.

The first time you try to connect a mask appears for entering the “Site Key” for which Progea must be asked. Should you not yet be in possession of this code, the project can be run in DEMO mode (a message appears indicating the type of mode).

If you want the project to be activated automatically on switching on the ter-minal, you will have to introduce the file Startup.esa and compile it as follows (see also “Chapter 11 -> Automatic execution of applications“).

\FlashDisk\My path\MovCe.exe \FlashDisk\My path\My project.prj

where My path must be replaced with the complete path of where the respective files are to be found. For example:

\FlashDisk\Movicon\MovCe.exe\FlashDisk\My project\My project.prj

Search the folders until you find the project to be run.

Select the desired.

Click on OK.

Compile using the code supplied by Progea.

Click on OK.

Page 126: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 127: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-1

Chapter 15 Creating a project with ZenOn

Contents Page

Installation 15-2

The project 15-3

Choosing the device to connect to the VTCE 15-5

Entering the variables 15-8

Transfer of ZenOn files to VTCE terminal 15-11

Transferring a project to the VTCE terminal 15-12

This chapter consists of 14 pages.

Page 128: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-2

This chapter deals EXCLUSIVELY with the settings and procedures needed to use a ZenOn project with Windows CE.

A project can be created to function directly with a VTCE terminal and devices supported by Zenon or, when an optional card (CIB) is added to the terminal, projects can be created that function with VTCE terminals and all the devices supported by ESA.

A knowledge of ZenOn is indispensable in order to be able to fol-low this chapter. Without this, it is better to turn to the documen-

tation coming from the producer or the COPA-DATA Technical Assistance.

Installation The installation procedure is divided in two parts: the first consists in the installation of the basic version of ZenOn, after which the updated ZenOn CE is installed, which allows you to create projects for VTCE terminals (see also “Chapter 13 -> Software compatibility“).

What is set out below may be modified by COPA-DATA at any point with ESA knowing, consequently the installation procedure

described here may include some imprecision as to details.

Without optional CIB board

Devices sup-ported by ZenOn

With optional CIB board

All devices supported by

ESA

Serial COM1

MSP + ASP

MSP + CAN

Page 129: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-3

If problems of installation are encountered or clarifications regarding the installation procedure are required, it is better to

turn to the documentation coming from the producer or the COPA-DATA Technical Assistance.

Put the Cd-Rom into the appropriate drive; if the PC’s “automatic loading notification” has been activated, the ZenOn presentation will start automat-ically, if not, click on Start > Run…

Digit e:\Setup.bat and confirm with OK.

If the drive to be used is not “e:”, digit the appropriate letter.

Follow the on-screen instructions.

It is recommended that “Complete Installation” be selected for the installation phase.

Once the ZenOn installation has been completed, proceed with the ZenOn CE update.

Proceed as for the preceding point; if it does not start automatically click on Start > Run… and digit e:\zenOn_CE_Setup.exe then confirm with OK.

Again follow the on-screen instructions.

The ZenOn CE destination folder must be the same as that in which ZenOn has been installed.

The project As already mentioned, the projects can be created work both with and with-out a CIB board. The configuration mode changes slightly depending on the type of project that you wish to create. Consequently there is an explicit indication of those operations to be carried out only when there is a CIB board. Where there is no such specification, the operations should consid-ered as common to both types of project.

A project can be created without having a VTCE available.

A knowledge of ZenOn is indispensable in order to be able to follow this chapter. Without this, it is better to turn to the documentation

coming from the producer or the COPA-DATA Technical Assistance.

Settings for projects for Windows CE

After creating a project click on File > Project configuration > project...

Page 130: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-4

Note:• When using transfer by Ethernet network (b) the XXX must be replaced

with the TCP/IP address of the VTCE terminal connected and must be followed by a semi-colon ( ; ). For further details regarding the connec-tions see “Chapter 11 -> Using the system“.

Select the project WindowsCE (1).

Then select the Remote transport.

1

This mask is used to define, among other parameters, the mode of transfer of the project to the VTCE terminal (1) and the destination folder (2).

1) Transfer can be over the Serial port (a) or over the Ethernet network (b). Set as in figure (a) or (b), depending on the choice made.

2) Enter the complete destination path of the project. The path refers to the VTCE terminal.

Click on OK close the mask and accept the settings.

2

1

a

b

Page 131: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-5

• The destination path depends on the support you want your project to be on:

• Hard disk -> \FlashDisk\My path\• PCMCIA -> \Storage Card\My path\

Other paths are possible, but all data is lost when the VTCE terminal is switched off (see “Chapter 10 -> Basic concepts“).

• It is sufficient to set the principal path and all the subfolders of the project will adopt the same path as their destination.

Choosing the device to connect to the VTCE

After having made the settings as shown on Page 15-3 proceed to choose the device to connect to the terminal.

Click on the Tools > Select Driver...

Direct connection

Use the list of devices to choose the one to be connected to the terminal; select it and click on Ok. A configuration window now appears. Set the parameters as required for the device to be connected. Click on the Ok to accept the changes.

The choice of the driver depends on the device to connect and the type of connection -- direct or using a CIB board (OPC Server).

The two procedures are detailed below.

Page 132: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-6

Connection using CIB board (OPC Server)

Before proceeding, check that you have:• created and compiled a project using CIBWIN (see CIB board manual).• installed and correctly set OPCSrvESA (see CIB board manual).

Choose the following driver from the list of devices:

Select the driver as in the figure.

Click on the OK.

Set parameters according to the requirements of the project.

Select the OPC.

Page 133: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-7

Click on ... to select the OPC Server.

Select the driver as in the figure.

Click on the OK.

Set as shown in the figure.

Click on the OK.

Page 134: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-8

Entering the variables

Click on the Tools > Variables list...

The information contained in the mask that is displayed depends on the driver selected (whether Direct connection or via a CIB

board).

Variable for direct connection

From the list of the types of variable supported choose the one you wish, select it and click on the Ok and a defining window appears. Set the parameters as required by the device to be connected. Click on the Ok to accept the changes, then click on Exit to accept and leave the masks that are displayed.

Variable for connection via CIB board see (OPC Server)

Before proceeding check that you have:• created and compiled a project with CIBWIN (see CIB board manual).• installed and correctly set OPCSrvESA (see CIB board manual).• selected the correct OPC Client driver (see Page 15-6 -> “Connection

using CIB board (OPC Server)“).

The types supported are: Boolean, i/u8Bit, i/u16Bit, i/u32Bit, float32 and String.

Click on the New to enter the variable.

Select the type required, for example as shown in the figure.

Click on the New.

Page 135: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-9

The list also includes the system variables. For their meaning see CIB board manual.

Choose the variable to import from among those defined with CIBWIN.

Click on the Selection...

Choose the variable you want.

Click on the Ok.

Page 136: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-10

Complete the project with all the elements necessary.

Enter the parameters of the variable selected and imported. Complete the setting in accordance with the requirements of the project.

Click on the Ok.

The type of variable entered is highlighted.

Click on the Exit.

The type of variable entered is highlighted.

Click on the Exit.

Page 137: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-11

Transfer of ZenOn files to VTCE terminal

To transfer projects, ZenOn uses a program (SysSrvCE.exe) that must be installed on the VTCE terminal which functions as a server for the trans-mission. The first time you transfer the server is activated automatically. Thereafter, every time you need to establish a communication between ZenOn and the VTCE terminal you need to activate the server manually by double-clicking on the file.

Before continuing check that there is a Serial and/or Ethernet connection (see “Chapter 11 -> Using the system“) between PC and VTCE.

The first time you transfer the project it is INDISPENSABLE to use the serial cable connection and to have established the connec-

tion by means of Microsoft Active Sync (see “Chapter 11 -> Using the system“).

Click on the Options > CE Runtime Update

Select the Source.

Certain parameters must be set: these relate to the VTCE terminal connected.

Select as in the figure.

Then select the Options.

Page 138: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-12

From the Launch click on the Process. Then follow the on-line instruc-tions.

Once the transfer has been completed, exit by clicking on the Save & Exit.

Sometimes, for reasons not attributable to ESA, the processor that has been mounted on the terminal is not recognized by ZenOn,

consequently every time the message “Processor: UNKNOWN” is dis-played in the transfer mask, the operations carried put in the Sources must be repeated.

If everything works well the VTCE terminal will show a mask like that below.

Transferring a project to the VTCE terminal

When all the files ZenOn needs to manage the project on the VTCE termi-nal have been transferred the remote connection can be activated.

Click on and the mask shown below is displayed. It can be used to define a protection password to stop unauthorized users from elaborating a project.

1) Set the language wanted in display.

2) Set the parameters for Ethernet or Serial transmission (see Page 15-4 -> “Note:“).

3) Set as in figure, entering the path you want (see Page 15-4 -> “Note:“).

Select path then the Launch.

2

1

3

Page 139: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-13

The first time the connection is attempted, a mask appears for entering the “Series number” that must be requested from COPA-DATA.

If the codes are correct and the remote communication is active, the toolbar for transferring to the terminal comes on.

Proceed with generating the runtime files that have to be transferred to the

VTCE terminal. Click on . The “Issue window” shows the files gener-ated.

Proceed now to the transfer of the project files. Click on . The “Issue window” shows the files transported.

Click on to set the project that must be remotely activated.

If the project requires the use of a CIB board, before activating the project on the VTCE check that:

• the OPC Server library has been installed and registered (see CIB board manual).

• the files generated by CIBWIN have been introduced (see CIB board manual).

Enter the password desired.

Click on OK.

Compile using the codes supplied by COPA-DATA.

Click on OK.

1) Remote transport NOT active.

2) Remote transport active.

1 2

Page 140: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 15Creating a project with ZenOn

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

15-14

Once the above points have been checked (only in the case of the CIB board) proceed with activating the project.

Click on to activate the remote project.

Click on to deactivate the remote project.

To activate the project without being connected with ZenOn you must dou-ble-click on the file ZenOnRCE.exe situated in the project installation folder.

If you want the switching on of the terminal automatically to activate the project, you need to introduce the file Startup.esa and compile it as below (see also “Chapter 11 -> Automatic execution of applications“).

\My path\ZENONRCE.exe

Where My path must be substituted with the complete path with which the project may be found, for example:

\FlashDisk\Zenon\My project\ZENONRCE.exe

Page 141: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

16-1

Chapter 16 Technical support

Contents Page

International Customer Care 16-2

International Product Returns 16-2

This chapter consists of a total of 4 pages.

Page 142: 405_1200_048_2 - Commissioning Manual - Rel 2_00

CHAPTER 16Technical support

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

16-2

International Customer Care

The International Customer Care service can be contacted by:

Telephone:++39-031757400

Fax: ++39-031751777

E-Mail: [email protected]

Web site: http://www.esahmi.it

International Product Returns

Should it be necessary to return the VTCE terminal for repair:

• Contact our International Customer Care service to authorize the return.• Fill in all parts of the form to accompany the product.

Our International Customer Care service will supply all the necessary infor-mation for returning a an item.

Thank you for your kind co-operation.

!!! IMPORTANT NOTE !!!

ESA elettronica S.p.A. will accept:• goods carriage free / freight prepaid (transport at customer’s cost).• goods carriage forward / freight collect (transport paid by ESA) only

with the prior authorization of the company.

ESA elettronica S.p.A. will reject:• any returned goods carriage forward where there has been no prior

authorization.

It is not necessary to send connectors, cables and accessories (unless they are thought to be linked to the problem indicated).

Page 143: 405_1200_048_2 - Commissioning Manual - Rel 2_00

NOTE: Please complete form in BLOCK CAPITALS.

Returned goods code: ............................................

Customer Care worker contacted: ............................................................................

Date of compilation: ...../...../........ Signature: ...............................................................

ESA elettronica S.p.A. Via Padre Masciadri, 4/A - 22066 Mariano C.se (Co) ITALYTel. ++39-031757400 Fax ++39-031751777 C.F. 12508520157 P.IVA IT 02422110136

REPAIRS RETURN FORM

S/N:Product: ..............................................

Town : County:

Post Code:...................................................................... .....................

................................................. ...........................................

Compiled by :

Company :

Full address :

Customer details (must be filled in)

Tel. no. : Fax:

...............................................................................................................

...............................................................................................................

.................................................. ...................................................

Name :

Contact person (where different from above)

Tel. no. : Fax:

.................................................................................................................

.................................................. ...................................................

Device connected:

Information regarding problem (must be filled in)

...............................................................................................

Detailed description of the problem and the circumstances under which it occurs:

.....................................................................................................................................

.....................................................................................................................................

.....................................................................................................................................

.....................................................................................................................................

.....................................................................................................................................

.....................................................................................................................................

.....................................................................................................................................

Notes:

.....................................................................................................................................

.....................................................................................................................................

..........................................................................................................................

Page 144: 405_1200_048_2 - Commissioning Manual - Rel 2_00
Page 145: 405_1200_048_2 - Commissioning Manual - Rel 2_00

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

IA-1

Index

A

Accessories, 10, 9Accessories connectable to VTCE terminals, 2Adapter PC 25F VTCE 9M, 3Automatic execution of applications, 19

B

Basic concepts, 1

C

Calibrating the Touch Screen, 2Calibration of Touch Screen, 9Caratteristiche tecniche, 2Cell battery, 4Chemical substances, 2Choosing the device to connect to the VTCE, 5CIB board - MSP, ASP, 10CIB board - MSP, CAN, 11Cleaning the VTCE, 7Compatibility with VTCE, 2, 3COM1 serial port, 3Connection in Ethernet, 10Connection pins, 2Connection using CIB board (OPC Server), 6Connections to be avoided, 3Creating a project with Movicon, 1Creating a project with ZenOn, 1Customizing label, 6, 5

D

Dima di foratura, 9, 8Direct connection, 5Direct PC / VTCE connection using Ethernet, 4Disturbance suppression circuit - RC and DIODE, 3

E

Earthing of shielding and electronic circuits, 2Enabling communication with remote terminals, 3Entering the variables with ZenOn, 8Ethernet crossover cable, 5Ethernet network port, 7Exploring the PC, 8

F

Flash Disk, 2Frontale, 4

G

General notes, 2

I

Inserting customized labels, 1Installation of Movicon, 2Installation of ZenOn, 2International Customer Care, 2International Product returns, 2

K

Keyboard PS/2 port, 6

L

Label, 2Laying cables, 2LPT parallel port, 4

M

Managing the Fonts, 21Minimum HW requirements, 2Mounting the terminal within the container, 1Mouse PS/2 port, 5Movicon, 2MSP, ASP and CAN serial ports, 9

N

Note, 4Notes, 4Null modem cable PC 25F VTCE 9F, 6Null modem cable PC 9F VTCE9F, 7

P

PC / VTCE connection using serial port, 14Posteriore, 7

Page 146: 405_1200_048_2 - Commissioning Manual - Rel 2_00

INDEX

405.1200.048.2 - Rel.: 2.00 of 15/05/2003

IA-2

Power Supply, 1Protfilm10/12, 8

R

RAM, 2Recommended connection, 2Recommended HW requirements, 3Resistance to chemical substances, 1

S

Saving the Registry, 2Settings for projects for Windows CE with Movicon, 3Settings for projects for Windows CE with ZenOn, 3Shielding of cables, 2Software compatibility, 1Standard series rear view, 6Storage Card, 2Switching of capacitive loads, 2Switching off inductive loads, 2

T

Testing the connection, 7The project with Movicon, 3The project with ZenOn, 3Transfer of ZenOn files to VTCE terminal, 11Transferring a project to a VTCE with Movicon, 4Transferring a project to the VTCE terminal with

ZenOn, 12Transferring Movicon files to a VTCE, 3

U

USB serial port, 8Using nuts, 2Using the system, 1

V

Variable for connection via CIB board see (OPC Server), 8

Variable for direct connection, 8VTCE video terminal accessories, 1

W

Warnings, 2What is a CE Video Terminal, 1

Z

Zenon, 3


Recommended