    FIRE FIGHTING

  • 8/3/2019 4[1].Fire Fighting

    2/41

    FIRE TRIANGLE

    FUEL

    VAPOUR OXYGEN

    HEAT

  • 8/3/2019 4[1].Fire Fighting

    3/41

    TO COMBAT A FIRE, WE CAN REMOVE ANY ONECOMPONENT IN THE FIRE TRIANGLE OR THE CHAINREACTION IN THE FIRE TETRAHEDRON

    HEAT COMPONENT - COMBAT BY COOLING

    OXYGEN COMPONENT - COMBAT BY SMOTHERING

    FUEL - COMBAT BY STARVATION

  • 8/3/2019 4[1].Fire Fighting

    4/41

    CLASSIFICATION OF FIRE

    CLASS A FIRES WOOD BASE MATERIALS

    TEXTILES & FIBRES PLASTIC & RUBBER

    CLASS B FIRES FLAMMABLE LIQUIDS COMBUSTIBLE LIQUIDS PAINTS & VARNISHES FLAMMABLE GASES

  • 8/3/2019 4[1].Fire Fighting

    5/41

    CLASS C FIRES

    GENERATORS MOTORS

    WIRING SWITCHES, FUSES

    CLASS D FIRES

    SODIUM POTASSIUM MAGNESIUM TITANIUM, ALUMINIUM

  • 8/3/2019 4[1].Fire Fighting

    6/41

    FIRE! FIRE! FIRE!

    WHEN A FIRE IS SIGHTED NO MATTER HOW SMALL IT IS, THEINITIAL ACTION SHOULD BE TO SOUND THE ALARM.

    CABIN FIRE WHEN THE FIRE ALARM IS SOUNDED, RUSH TO THE

    MUSTER STATION HEAD COUNT IS CARRIED OUT AND ANY MISSING PERSON

    MUST BE DETERMINED REPORT TO THE BRIDGE AND AWAIT FOR THE ORDERS

    FROM THE MASTER FIRE FIGHTING PARTY TO DON THE FIRE FIGHTERS

    OUTFIT AND THE BA SET THE BACK-UP PARTY STANDBY WITH THE FIRE FIGHTERS

    OUTFIT AND THE BA SET

  • 8/3/2019 4[1].Fire Fighting

    7/41

    FIRST AID PARTY GETS READY AND STAND BY IDENTIFY THE ZONE OF FIRE (FROM THE FIRE DETECTION

    PANEL) IDENTIFY THE TYPE OF FIRE OR THE POSSIBILITY- CLASS

    C OR CLASS A SHUT ALL THE VENTILATORS, AIR-CON, DAMPERS, FIRE

    DOORS AND ANY OTHER OPENINGS PROCEED TO THE ZONE OF FIRE. ENTER WITH A WATER

    HOSE UNDER PRESSURE. USE WATER SPRAY AS A SHIELD IF NECESSARY WHEN

    ENTERING IF A POSSIBILITY OF FIRE IS SUSPECTED INSIDE A

    CABIN, FEEL THE DOOR WITH THE BACK OF THE PALM. IFHOT FIRE IS NOT DEAD.

    ONCE FIRE IS EXTINGUISHED IT MUST BE REPORTED TOTHE BRIDGE

    FIRE WATCH IS MAINTAINED AND THE CAUSE ISINVESTIGATED

  • 8/3/2019 4[1].Fire Fighting

    8/41

    CARGO HOLD FIRE

    WHEN THE FIRE ALARM IS SOUNDED RUSH TO THE MUSTERSTATION HEAD COUNT IS CARRIED OUT AND ANY MISSING PERSON

    MUST BE DETERMINED REPORT TO THE BRIDGE AND AWAIT FOR THE ORDERS FROM

    THE MASTER FIRE FIGHTING PARTY TO DON THE FIRE FIGHTERS OUTFIT

    AND BA SET THE BACK-UP PARTY STANDBY WITH THE FIRE FIGHTERS

    OUTFIT AND THE BA SET FIRST AID PARTY GETS READY AND STAND BY THE MASTER THEN CHECKS THE DANGEROUS GOODS

    STOWAGE PLANS & CHECKS IF ANY DANGEROUS CARGO INTHE HOLD

    IF DANGEROUS CARGO IS PRESENT THEN THE MASTERIDENTIFIES THE TYPE OF CARGO AND CHECKS THE IMDGCODE FOR THE TYPE OF FIRE FIGHTING MEASURES TO BETAKEN

  • 8/3/2019 4[1].Fire Fighting

    9/41

    IF DANGEROUS CARGO IS PRESENT THEN THE TEAM SHOULDWEAR THE CHEMICAL SUIT

    ALL VENTILATORS, BOOBY HATCH COVERS AND CARGO HOLDFANS ARE SHUT

    FIRE FIGHTING TEAM THEN PROCEEDS TO THE CARGO HOLD,WHILE THE BACK-UP TEAM CARRIES OUT BOUNDARY

    COOLING IF CO2 TO BE USED,AGAIN THIS SHOULD BE THE LAST

    RESORT IF ANY PERSON IS SUSPECTED TO BE INSIDE

    ONCE THE FIRE IS SUSPECTED TO BE EXTINGUISHED, ENTERTHE HOLD AND CONFIRM VISUALLY

    WHEN ENTERING THE HOLD DURING OR AFTER

    EXTINGUISHING A LIFE-LINE MUST BE ATTACHED TO THEPERSONS ENTERING

    FINALLY THE CAUSE OF FIRE TO BE INVESTIGATED

  • 8/3/2019 4[1].Fire Fighting

    10/41

    PAINT ROOM FIRE WHEN THE FIRE ALARM IS SOUNDED, RUSH TO THE MUSTER

    STATION HEAD COUNT IS CARRIED OUT AND ANY MISSING PERSON

    MUST BE DETERMINED

    REPORT TO THE BRIDGE AND AWAIT FOR ORDERS FROM THEMASTER

    FIRE FIGHTING PARTY TO DON THE FIRE FIGHTERS OUTFITAND BA SET

    THE BACK-UP PARTY STANDBY WITH THE FIRE FIGHTERSOUTFIT AND THE BA SET

    FIRST AID PARTY GETS READY AND STAND BY

    PAINT ROOM OPENINGS ARE SHUT

    WATER SPRINKLER IS ACTIVATED BY OPENING THESPRINKLER VALVE LOCATED OUTSIDE THE PAINT ROOM

    FIRE FIGHTING PARTY APPLIES BOUNDARY COOLING

    ONCE FIRE IS PUT OUT IT MUST BE REPORTED TO BRIDGE

    FIRE WATCH IS MAINTAINED & THE CAUSE INVESTIGATED

  • 8/3/2019 4[1].Fire Fighting

    11/41

  • 8/3/2019 4[1].Fire Fighting

    12/41

  • 8/3/2019 4[1].Fire Fighting

    13/41

  • 8/3/2019 4[1].Fire Fighting

    14/41

  • 8/3/2019 4[1].Fire Fighting

    15/41

    FFA REQUIREMENT AS

    PER SAFETY CONVENTION

    REGULATIONSEVERY SHIP SHALL BE PROVIDED WITH FIRE PUMPS, FIRE

    MAINS, HYDRANTS AND HOSES. SHIPS SHALL BE PROVIDEDWITH INDEPENDENTLY DRIVEN FIRE PUMPS AS FOLLOWS:

    PASSENGER SHIPS OF 4000GRTAND UPWARDS

    AT LEAST 3

    PASSENGER SHIPS OF LESS

    THAN 4000GRT AND CARGOSHIPS OF 1000GRT ANDUPWARDS

    AT LEAST 2

    CARGO SHIPS OF LESS THAN1000GRT

    AT LEAST 2 POWER-DRIVEN, 1OF WHICH SHALL BE

    INDEPENDENTLY DRIVEN

  • 8/3/2019 4[1].Fire Fighting

    16/41

    DIAMETER OF THE FIRE MAINS SHALL BE SUFFICIENTFOR THE EFFECTIVE DISTRIBUTION OF THE MAXIMUM

    REQUIRED DISCHARGE FROM THE TWO FIRE PUMPSOPERATING SIMULTANEOUSLY, EXCEPT IN THE CASEOF CARGO SHIPS WHERE THE DIAMETER NEED ONLY BESUFFICIENT FOR THE DISCHARGE OF 140m/h.

    THE NUMBER AND POSITION OF HYDRANTS SHALL BESUCH THAT AT LEAST TWO JETS OF WATER NOTEMANATING FROM THE SAME HYDRANT, ONE OFWHICH SHALL BE FROM A SINGLE LENGTH OF HOSE,MAY REACH ANY PART OF THE SHIP NORMALLYACCESSIBLE TO THE PASSENGERS OR CREW.

    IN PASSENGER SHIPS THERE SHALL BE AT LEAST ONEFIRE HOSE FOR EACH OF THE HYDRANTS. THESESHALL BE USED ONLY FOR THE PURPOSE OFEXTINGUISHING FIRES OR TESTING DURING FIREDRILLS AND SURVEYS.

  • 8/3/2019 4[1].Fire Fighting

    17/41

    IN CARGO SHIPS OF 1000GRT AND UPWARDS THE NUMBER

    OF FIRE HOSES TO BE PROVIDED SHALL BE ONE FOREACH 30M LENGTH OF THE SHIP AND ONE SPARE BUTIN NO CASE LESS THAN FIVE IN ALL. THIS NUMBERDOES NOT INCLUDE ANY HOSES REQUIRED IN ANYENGINE OR BOILER ROOM.

    IN CARGO SHIPS OF LESS THAN 1000GRT THE NUMBER OFFIRE HOSES SHALL BE TO THE SATISFACTION OF THEADMINISTRATION.

    IN ADDITION SHIPS CARRYING DANGEROUS CARGOSHALL BE PROVIDED 3 HOSES AND NOZZLES.

    EACH FIRE HOSE SHALL BE PROVIDED WITH A NOZZLEAND THE NECESSARY COUPLINGS

  • 8/3/2019 4[1].Fire Fighting

    18/41

    INTERNATIONAL SHORE

    CONNE

    CTION

    SHIPS OF 500GRT AND UPWARDS SHALL CARRY AT LEASTONE INTERNATIONAL SHORE CONNECTION. USED ON

    EITHER SIDE OF THE SHIP.

    IT IS KEPT ONBOARD ALONG WITH A GASKET FOR1N/mm, TOGETHER WITH FOUR 16mm BOLTS, 50mm INLENGTH AND 8 WASHERS.

  • 8/3/2019 4[1].Fire Fighting

    19/41

    FIXED FIRE EXTINGUISHING

    SYSTEMS

    FIXED FIRE EXTINGUISHING SYSTEMS INCLUDE:

    A FIXED HIGH-EXPANSION FOAM FIRE

    EXTINGUISHING SYSTEM

    A FIXED PRESSURE WATER SPRAYING FIRE

    EXTINGUISHING SYSTEM

  • 8/3/2019 4[1].Fire Fighting

    20/41

    FIXED GAS FIRE EXTINGUISHING

    SYSTEMSTHE NECESSARY PIPES FOR CONVEYING FIRE EXTINGUISHING

    MEDIUM INTO PROTECTED SPACES SHALL BE PROVIDEDWITH CONTROL VALVES MARKED SO AS TO INDICATE THESPACES TO WHICH THE PIPES ARE LED.

    MEANS SHALL BE GIVEN FOR AUTOMATICALLY GIVING AUDIBLEWARNING OF THE RELEASE OF FIRE EXTINGUISHINGMEDIUM INTO ANY SPACE IN WHICH PERSONNEL NORMALLYWORK OR TO WHICH THEY HAVE ACCESS.

    AUTOMATIC RELEASE OF FIRE EXTINGUISHING MEDIUM ISNOT ALLOWED. e.g.

    CARBON DIOXIDE SYSTEMS MACHINERY SPACES

    INERT GAS SYSTEMS CARGO TANKS

  • 8/3/2019 4[1].Fire Fighting

    21/41

    PASSENGER SHIPS OF >36 PAX SHALL BE EQUIPPED WITHAUTOMATIC SPRINKLER SYSTEM IN ALL CONTROLSTATIONS, CORRIDORS AND STAIRWAYS

    PASSENGER SHIPS OF < 36 PAX AUTOMATIC SPRINKLERSYSTEM SHALL BE PLACED IN THE CORRIDORS,STAIRWAYS, ETC WITHIN ACCOMODATION SPACESACCCORDING TO THE REQUIREMENTS OF THEADMINISTRATION

    CARGO SHIPS SHALL BE PROVIDED WITH FIXED FIREFIGHTING SYSTEMS IN CARGO SPACES, PUMP-ROOM,GALLEY AND MACHINERY SPACE

  • 8/3/2019 4[1].Fire Fighting

    22/41

    FIRE FIGHTERS OUTFITS

    FIRE FIGHTERS OUTFIT SHALL COMPLY WITH THEREQUIREMENTS OF THE FIRE SAFETY SYSTEM CODE.

    ALL SHIPS SHALL CARRY AT LEAST TWO FIRE FIGHTERSOUTFIT. IN ADDITION:

    PASSENGER SHIPS FOR EVERY 80m, TWO OUTFITS ANDTWO PERSONAL EQUIPMENT

    PASSENGER SHIPS >36 PAX, TWO FIRE FIGHTING OUTFITSFOR EACH MAIN VERTICAL ZONE

    TANKERS, TWO FIRE FIGHTERS OUTFITS CARGO SHIPS & PASSENGER SHIPS >36 PAX, TWO SPARE

    CHARGES FOR EACH BA, OR ONE SPARE CHARGE IF CAPABLEOF BEING RECHARGED AT SEA FOR CARGO SHIPS AND

    PASSENGER SHIPS

  • 8/3/2019 4[1].Fire Fighting

    23/41

  • 8/3/2019 4[1].Fire Fighting

    24/41

  • 8/3/2019 4[1].Fire Fighting

    25/41

  • 8/3/2019 4[1].Fire Fighting

    26/41

  • 8/3/2019 4[1].Fire Fighting

    27/41

  • 8/3/2019 4[1].Fire Fighting

    28/41

    EMERGENCY ESCAPE

    BREATHING DEVIC

    ES

    EEBD CAN BE USED TO HELP ESCAPE FROM A SPACE WHICHIS FILLED WITH SMOKE OR TOXIC GASES. IT ISLOCATED WHERE IT IS ACCESSIBLE TO ALL. SHIPS NEED

    TO CARRY THE FOLLOWING NUMBER OF EEBDS:

    ALL SHIPS AT LEAST 2 EEBD WITHIN ACCOMMODATION

    IN PASSENGER SHIPS AT LEAST TWO EEBD IN EACH

    MAIN VERTICAL ZONE

    ADDITIONAL TWO EEBD FOR PASSENGER SHIPS >36 PAX

  • 8/3/2019 4[1].Fire Fighting

    29/41

    FIXED FIRE DETECTION & ALARM

    SYSTEMSTHE PURPOSE OF THIS IS TO DETECT ANY FIRE IN THE SPACE

    OF ORIGIN AND TO PROVIDE ALARM FOR SAFE ESCAPE ANDFIRE FIGHTING ACTIVITY. FOR THIS PURPOSE THEFOLLOWING REQUIREMENTS SHALL BE MET:

    FIXED FIRE DETECTION AND ALARM SYSTEMS SHALL BESUITABLE FOR THE NATURE OF THE SPACE, FIRE GROWTHPOTENTIAL AND POTENTIAL GENERATION OF SMOKE &GASES

    MANUALLY OPERATED CALL POINTS SHALL BE PLACED

    EFFECTIVELY TO ENSURE A READILY ACCESSIBLE MEANS OFNOTIFICATION FIRE PATROLS SHALL PROVIDE AN EFFECTIVE MEANS OF

    DETECTING AND LOCATING FIRES & ALERTING THENAVIGATION BRIDGE & TEAMS

  • 8/3/2019 4[1].Fire Fighting

    30/41

    SMOKE DETECTORS SHALL BE INSTALLED IN ACCOMODATION

    SPACES, ESCAPE ROUTES, ETC

    PASSENGER SHIPS >36 PAX - FIXED FIRE DETECION &ALARM SYSTEMS SHALL BE INSTALLED IN ACCOMODATIONSPACES, SERVICE SPACES, CONTROL STATIONS, ETC EXCEPTIN BATHROOMS, PUBLIC TOILETS, CO ROOMS

    PASSENGER SHIPS

  • 8/3/2019 4[1].Fire Fighting

    31/41

    DONT SLEEP!

  • 8/3/2019 4[1].Fire Fighting

    32/41

  • 8/3/2019 4[1].Fire Fighting

    33/41

  • 8/3/2019 4[1].Fire Fighting

    34/41

    PORTABLE FIRE EXTINGUISHERS

    THESE SHALL COMPLY WITH THE REQUIREMENTS OF THE FIRESAFETY SYSTEM CODE.

    ACCOMODATION SPACES, SERVICE SPACES & CONTROLSTATIONS SHALL BE PROVIDED WITH PORTABLE FIRE

    EXTINGUISHERS OF APPROPRIATE TYPE AND IN SUFFICIENTNUMBER REQUIRED BY THE ADMINISTRATION. SHIPS>1000GRT SHALL CARRY AT LEAST 5 PORTABLEEXTINGUISHERS

    THESE EXTINGUISHERS SHALL BE PLACED AT THE ENTRANCEOF THE PLACE WHERE IT IS INTENDED TO USE

    CO2 EXTINGUISHERS SHALL NOT BE PLACED INACCOMODATION SPACES. IN CONTROL STATIONS ANDOTHER SPACES WHERE THERE ARE ELECTRICAL EQUIPMENTSNECESSARY FOR THE SAFETY OF SHIP, EXTINGUISHERSSHALL BE PROVIDED WHICH ARE NOT ELECTRICALLYCONDUCTIVE OR HARMFUL TO THE EQUIPMENT

  • 8/3/2019 4[1].Fire Fighting

    35/41

    PORTABLE EXTINGUISHERS SHALL BE PROVIDED WITHDEVICE WHICH INDICATES WHETHER THEY HAVE BEEN USEDOR NOT

    THERE SHALL BE ONE PORTABLE FOAM APPLICATOR UNIT ATTHE ENTRANCE OUTSIDE OR IN THE BOILER ROOM. THERESHALL BE AT LEAST TWO SIMILAR EXTINGUISHERS OREQUIVALENT IN EACH FIRING SPACE IN THE BOILER ROOM.THESE EXTINGUISHERS SHALL BE PROVIDED WITH HOSESON REELS

    THERE SHALL BE SUFFICIENT FOAM TYPE EXTINGUISHERS

    OF AT LEAST 45 LITRES OR EQUIVALENT TO BE DIRECTEDONTO ANY PART OF LUBE OIL PRESSURE SYSTEMS, GEARINGOR OTHER FIRE HAZARDS

    IN ADDITION THERE SHALL BE SUFFICIENT NUMBER OFPORTABLE FOAM OR EQUIVALENT EXTINGUISHERS WITHINMACHINERY SPACE SO PLACED THAT NO POINT IN THE

    SPACE IS MORE THAN 10m WALKING DISTANCE FROM ANEXTINGUISHER PORTABLE EXTINGUISHERS OF 12kg OF DRY POWDER SHALL

    BE PROVIDED IN THE CARGO HOLD SPACES. PORTABLEEXTINGUISHERS SHALL BE PROVIDED AT EACH DECK LEVELIN EACH HOLD, SPACE NOT MORE THAN 20m APART ON BOTHSIDES OF THE SPACE

  • 8/3/2019 4[1].Fire Fighting

    36/41

    ROUTINE CHECKS &

    MAINTENANC

    EFIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN

    GOOD WORKING ORDER & READILY AVAILABLE FORIMMEDIATE USE. PORTABLE EXTINGUISHERS WHICH HAVEBEEN DISCHARGED SHOULD BE IMMEDIATELY RECHARGED ORREPLACED WITH AN EQUIVALENT UNIT

    MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIEDOUT BASED ON THE GUIDELINES DEVELOPED BY THEORGANIZATION AND IN A MANNER HAVING DUE REGARD TOENSURING THE RELIABILITY OF FIRE FIGHTING SYSTEMSAND APPLIANCES. THE MAINTENANCE PLAN SHALL BE KEPT

    ON BOARD. IT SHALL INCLUDE AT LEAST THE FOLLOWINGFFA AND SYSTEMS:

    FIRE MAINS, FIRE PUMPS AND HYDRANTS, INCLUDINGHOSES, NOZZLES AND INTERNATIONAL SHORECONNECTION

  • 8/3/2019 4[1].Fire Fighting

    37/41

    FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS

    FIXED FIRE EXTINGUISHING SYSTEMS & FFA AUTOMATIC SPRINKLERS, FIRE DETECTION AND FIRE

    ALARMS

    VENTILATION SYSTEMS, INCLUDING FIRE AND SMOKEDAMPERS, FANS & THEIR CONTROLS

    EMERGENCY SHUTDOWN OF FUEL FIRE DOORS, INCLUDING THEIR CONTROLS

    EEBD

    PORTABLE FIRE EXTINGUISHERS, INCLUDING BA SETS ANDSPARE BOTTLES

    FIRE FIGHTERS OUTFIT

    CHEMICAL SUITS

  • 8/3/2019 4[1].Fire Fighting

    38/41

    CHECKS ON FIRE DETECTION SYSTEMS

    THE MAINTENANCE SHOULD INCLUDE TESTING: SMOKE DETECTORS USING THE SMOKE SPRAY CANISTERS

    INFRA FLAME DETECTORS USING TORCH LIGHT ORCIGARETTE LIGHTERS

    HEAT DETECTORS USING HAIR DRYERS

    TESTING THE SYSTEM TO ENSURE IT IS FUNCTIONINGNORMALLLY

    CHECKS ON CO2 SYSTEM CHECK THE LEVEL OF CO2 BOTTLE EITHER BY WEIGHING OR

    THE ISOTOPE METHODS

    CHECK THAT ALL THE ALARMS ARE WORKING PROPERLY

    CHECK THAT ALL THE CO2 OUTLETS ARE FREE OFOBSTRUCTION

  • 8/3/2019 4[1].Fire Fighting

    39/41

    CHECKS ON THE FOAM SYSTEM CHECK THAT THE FOAM IS VIABLE BY USING THE TEST KIT

    PROVIDED BY THE MAKERS CHECK THAT THE FOAM SPREADERS FROM THE ENGINE ROOM

    ARE NOT OBSTRUCTED CHECK THAT THE VALVES ARE GREASED AND NOT CORRODED

    OR JAMMED CHECK THAT THE DECK MONITORS ARE GREASED AND EASY

    TO ROTATE

    CHECKS ON FIRE MAIN, HYDRANTS, HOSES& NOZZLES

    THE INSPECTIONS INCLUDE: TESTING THE SYSTEM FOR LEAKS INSPECT PIPES FOR CORROSION OPEN DRAIN VALVES REGULARLY, ESPECIALLY IN COLD

    WEATHERS TO AVOID FREEZING OF WATER AND THEREBYCHOKING THE PIPELINES

  • 8/3/2019 4[1].Fire Fighting

    40/41

    THE VALVES ARE GREASED PROPERLY AND EASY TO MOVE

    PRESSURE TESTING HOSES

    TESTING SPRAY NOZZLES THROUGH THEIR OPERATINGRANGE

    REPLACE DAMAGED PARTS, LIKE BOLTS, COUPLINGS, ETC IFFOUND NON-FUNCTIONAL

    ORDER NEW SPARES

    CHECKS ON PORTABLE EXTINGUISHERS RECHARGE CYLINDERS ONCE USED

    BEFORE RECHARGING CHECK THE CYLINDER FOR CORROSION

    CHECK CYLINDER IF DUE FOR PRESSURE TEST

    CHECK THE TRIGGER VALVE FLUID IS TIGHT AND OPERATESFREELY

    CHECK OPERATION AND FLUID TIGHTNESS OF OTHERVALVES

  • 8/3/2019 4[1].Fire Fighting

    41/41

    ENSURE SAFETY PIN PUT IN CAP AFTER RECHARGING

    WRITE THE DATE OF TEST ON THE LABEL ATTACHED REPLACE CYLINDER IN PREVIOUS POSITION

    CHECKS ON FIRE FIGHTERS OUTFIT

    ALL OUTFITS ARE LOCATED IN THE CORRECT POSITIONS

    THE BATTERY OF THE SAFETY TORCH IS FULLY CHARGED THE BREATHING APPARATUS IS READY FOR USE AND FULLY

    CHARGED. IF NOT, RECHARGE

    LIFE LINE, FIRE AXE ARE ALL IN PLACE AND NOT DAMAGED

    RISE -END- SHINE