FIRE FIGHTING
8/3/2019 4[1].Fire Fighting
2/41
FIRE TRIANGLE
FUEL
VAPOUR OXYGEN
HEAT
8/3/2019 4[1].Fire Fighting
3/41
TO COMBAT A FIRE, WE CAN REMOVE ANY ONECOMPONENT IN THE FIRE TRIANGLE OR THE CHAINREACTION IN THE FIRE TETRAHEDRON
HEAT COMPONENT - COMBAT BY COOLING
OXYGEN COMPONENT - COMBAT BY SMOTHERING
FUEL - COMBAT BY STARVATION
8/3/2019 4[1].Fire Fighting
4/41
CLASSIFICATION OF FIRE
CLASS A FIRES WOOD BASE MATERIALS
TEXTILES & FIBRES PLASTIC & RUBBER
CLASS B FIRES FLAMMABLE LIQUIDS COMBUSTIBLE LIQUIDS PAINTS & VARNISHES FLAMMABLE GASES
8/3/2019 4[1].Fire Fighting
5/41
CLASS C FIRES
GENERATORS MOTORS
WIRING SWITCHES, FUSES
CLASS D FIRES
SODIUM POTASSIUM MAGNESIUM TITANIUM, ALUMINIUM
8/3/2019 4[1].Fire Fighting
6/41
FIRE! FIRE! FIRE!
WHEN A FIRE IS SIGHTED NO MATTER HOW SMALL IT IS, THEINITIAL ACTION SHOULD BE TO SOUND THE ALARM.
CABIN FIRE WHEN THE FIRE ALARM IS SOUNDED, RUSH TO THE
MUSTER STATION HEAD COUNT IS CARRIED OUT AND ANY MISSING PERSON
MUST BE DETERMINED REPORT TO THE BRIDGE AND AWAIT FOR THE ORDERS
FROM THE MASTER FIRE FIGHTING PARTY TO DON THE FIRE FIGHTERS
OUTFIT AND THE BA SET THE BACK-UP PARTY STANDBY WITH THE FIRE FIGHTERS
OUTFIT AND THE BA SET
8/3/2019 4[1].Fire Fighting
7/41
FIRST AID PARTY GETS READY AND STAND BY IDENTIFY THE ZONE OF FIRE (FROM THE FIRE DETECTION
PANEL) IDENTIFY THE TYPE OF FIRE OR THE POSSIBILITY- CLASS
C OR CLASS A SHUT ALL THE VENTILATORS, AIR-CON, DAMPERS, FIRE
DOORS AND ANY OTHER OPENINGS PROCEED TO THE ZONE OF FIRE. ENTER WITH A WATER
HOSE UNDER PRESSURE. USE WATER SPRAY AS A SHIELD IF NECESSARY WHEN
ENTERING IF A POSSIBILITY OF FIRE IS SUSPECTED INSIDE A
CABIN, FEEL THE DOOR WITH THE BACK OF THE PALM. IFHOT FIRE IS NOT DEAD.
ONCE FIRE IS EXTINGUISHED IT MUST BE REPORTED TOTHE BRIDGE
FIRE WATCH IS MAINTAINED AND THE CAUSE ISINVESTIGATED
8/3/2019 4[1].Fire Fighting
8/41
CARGO HOLD FIRE
WHEN THE FIRE ALARM IS SOUNDED RUSH TO THE MUSTERSTATION HEAD COUNT IS CARRIED OUT AND ANY MISSING PERSON
MUST BE DETERMINED REPORT TO THE BRIDGE AND AWAIT FOR THE ORDERS FROM
THE MASTER FIRE FIGHTING PARTY TO DON THE FIRE FIGHTERS OUTFIT
AND BA SET THE BACK-UP PARTY STANDBY WITH THE FIRE FIGHTERS
OUTFIT AND THE BA SET FIRST AID PARTY GETS READY AND STAND BY THE MASTER THEN CHECKS THE DANGEROUS GOODS
STOWAGE PLANS & CHECKS IF ANY DANGEROUS CARGO INTHE HOLD
IF DANGEROUS CARGO IS PRESENT THEN THE MASTERIDENTIFIES THE TYPE OF CARGO AND CHECKS THE IMDGCODE FOR THE TYPE OF FIRE FIGHTING MEASURES TO BETAKEN
8/3/2019 4[1].Fire Fighting
9/41
IF DANGEROUS CARGO IS PRESENT THEN THE TEAM SHOULDWEAR THE CHEMICAL SUIT
ALL VENTILATORS, BOOBY HATCH COVERS AND CARGO HOLDFANS ARE SHUT
FIRE FIGHTING TEAM THEN PROCEEDS TO THE CARGO HOLD,WHILE THE BACK-UP TEAM CARRIES OUT BOUNDARY
COOLING IF CO2 TO BE USED,AGAIN THIS SHOULD BE THE LAST
RESORT IF ANY PERSON IS SUSPECTED TO BE INSIDE
ONCE THE FIRE IS SUSPECTED TO BE EXTINGUISHED, ENTERTHE HOLD AND CONFIRM VISUALLY
WHEN ENTERING THE HOLD DURING OR AFTER
EXTINGUISHING A LIFE-LINE MUST BE ATTACHED TO THEPERSONS ENTERING
FINALLY THE CAUSE OF FIRE TO BE INVESTIGATED
8/3/2019 4[1].Fire Fighting
10/41
PAINT ROOM FIRE WHEN THE FIRE ALARM IS SOUNDED, RUSH TO THE MUSTER
STATION HEAD COUNT IS CARRIED OUT AND ANY MISSING PERSON
MUST BE DETERMINED
REPORT TO THE BRIDGE AND AWAIT FOR ORDERS FROM THEMASTER
FIRE FIGHTING PARTY TO DON THE FIRE FIGHTERS OUTFITAND BA SET
THE BACK-UP PARTY STANDBY WITH THE FIRE FIGHTERSOUTFIT AND THE BA SET
FIRST AID PARTY GETS READY AND STAND BY
PAINT ROOM OPENINGS ARE SHUT
WATER SPRINKLER IS ACTIVATED BY OPENING THESPRINKLER VALVE LOCATED OUTSIDE THE PAINT ROOM
FIRE FIGHTING PARTY APPLIES BOUNDARY COOLING
ONCE FIRE IS PUT OUT IT MUST BE REPORTED TO BRIDGE
FIRE WATCH IS MAINTAINED & THE CAUSE INVESTIGATED
8/3/2019 4[1].Fire Fighting
11/41
8/3/2019 4[1].Fire Fighting
12/41
8/3/2019 4[1].Fire Fighting
13/41
8/3/2019 4[1].Fire Fighting
14/41
8/3/2019 4[1].Fire Fighting
15/41
FFA REQUIREMENT AS
PER SAFETY CONVENTION
REGULATIONSEVERY SHIP SHALL BE PROVIDED WITH FIRE PUMPS, FIRE
MAINS, HYDRANTS AND HOSES. SHIPS SHALL BE PROVIDEDWITH INDEPENDENTLY DRIVEN FIRE PUMPS AS FOLLOWS:
PASSENGER SHIPS OF 4000GRTAND UPWARDS
AT LEAST 3
PASSENGER SHIPS OF LESS
THAN 4000GRT AND CARGOSHIPS OF 1000GRT ANDUPWARDS
AT LEAST 2
CARGO SHIPS OF LESS THAN1000GRT
AT LEAST 2 POWER-DRIVEN, 1OF WHICH SHALL BE
INDEPENDENTLY DRIVEN
8/3/2019 4[1].Fire Fighting
16/41
DIAMETER OF THE FIRE MAINS SHALL BE SUFFICIENTFOR THE EFFECTIVE DISTRIBUTION OF THE MAXIMUM
REQUIRED DISCHARGE FROM THE TWO FIRE PUMPSOPERATING SIMULTANEOUSLY, EXCEPT IN THE CASEOF CARGO SHIPS WHERE THE DIAMETER NEED ONLY BESUFFICIENT FOR THE DISCHARGE OF 140m/h.
THE NUMBER AND POSITION OF HYDRANTS SHALL BESUCH THAT AT LEAST TWO JETS OF WATER NOTEMANATING FROM THE SAME HYDRANT, ONE OFWHICH SHALL BE FROM A SINGLE LENGTH OF HOSE,MAY REACH ANY PART OF THE SHIP NORMALLYACCESSIBLE TO THE PASSENGERS OR CREW.
IN PASSENGER SHIPS THERE SHALL BE AT LEAST ONEFIRE HOSE FOR EACH OF THE HYDRANTS. THESESHALL BE USED ONLY FOR THE PURPOSE OFEXTINGUISHING FIRES OR TESTING DURING FIREDRILLS AND SURVEYS.
8/3/2019 4[1].Fire Fighting
17/41
IN CARGO SHIPS OF 1000GRT AND UPWARDS THE NUMBER
OF FIRE HOSES TO BE PROVIDED SHALL BE ONE FOREACH 30M LENGTH OF THE SHIP AND ONE SPARE BUTIN NO CASE LESS THAN FIVE IN ALL. THIS NUMBERDOES NOT INCLUDE ANY HOSES REQUIRED IN ANYENGINE OR BOILER ROOM.
IN CARGO SHIPS OF LESS THAN 1000GRT THE NUMBER OFFIRE HOSES SHALL BE TO THE SATISFACTION OF THEADMINISTRATION.
IN ADDITION SHIPS CARRYING DANGEROUS CARGOSHALL BE PROVIDED 3 HOSES AND NOZZLES.
EACH FIRE HOSE SHALL BE PROVIDED WITH A NOZZLEAND THE NECESSARY COUPLINGS
8/3/2019 4[1].Fire Fighting
18/41
INTERNATIONAL SHORE
CONNE
CTION
SHIPS OF 500GRT AND UPWARDS SHALL CARRY AT LEASTONE INTERNATIONAL SHORE CONNECTION. USED ON
EITHER SIDE OF THE SHIP.
IT IS KEPT ONBOARD ALONG WITH A GASKET FOR1N/mm, TOGETHER WITH FOUR 16mm BOLTS, 50mm INLENGTH AND 8 WASHERS.
8/3/2019 4[1].Fire Fighting
19/41
FIXED FIRE EXTINGUISHING
SYSTEMS
FIXED FIRE EXTINGUISHING SYSTEMS INCLUDE:
A FIXED HIGH-EXPANSION FOAM FIRE
EXTINGUISHING SYSTEM
A FIXED PRESSURE WATER SPRAYING FIRE
EXTINGUISHING SYSTEM
8/3/2019 4[1].Fire Fighting
20/41
FIXED GAS FIRE EXTINGUISHING
SYSTEMSTHE NECESSARY PIPES FOR CONVEYING FIRE EXTINGUISHING
MEDIUM INTO PROTECTED SPACES SHALL BE PROVIDEDWITH CONTROL VALVES MARKED SO AS TO INDICATE THESPACES TO WHICH THE PIPES ARE LED.
MEANS SHALL BE GIVEN FOR AUTOMATICALLY GIVING AUDIBLEWARNING OF THE RELEASE OF FIRE EXTINGUISHINGMEDIUM INTO ANY SPACE IN WHICH PERSONNEL NORMALLYWORK OR TO WHICH THEY HAVE ACCESS.
AUTOMATIC RELEASE OF FIRE EXTINGUISHING MEDIUM ISNOT ALLOWED. e.g.
CARBON DIOXIDE SYSTEMS MACHINERY SPACES
INERT GAS SYSTEMS CARGO TANKS
8/3/2019 4[1].Fire Fighting
21/41
PASSENGER SHIPS OF >36 PAX SHALL BE EQUIPPED WITHAUTOMATIC SPRINKLER SYSTEM IN ALL CONTROLSTATIONS, CORRIDORS AND STAIRWAYS
PASSENGER SHIPS OF < 36 PAX AUTOMATIC SPRINKLERSYSTEM SHALL BE PLACED IN THE CORRIDORS,STAIRWAYS, ETC WITHIN ACCOMODATION SPACESACCCORDING TO THE REQUIREMENTS OF THEADMINISTRATION
CARGO SHIPS SHALL BE PROVIDED WITH FIXED FIREFIGHTING SYSTEMS IN CARGO SPACES, PUMP-ROOM,GALLEY AND MACHINERY SPACE
8/3/2019 4[1].Fire Fighting
22/41
FIRE FIGHTERS OUTFITS
FIRE FIGHTERS OUTFIT SHALL COMPLY WITH THEREQUIREMENTS OF THE FIRE SAFETY SYSTEM CODE.
ALL SHIPS SHALL CARRY AT LEAST TWO FIRE FIGHTERSOUTFIT. IN ADDITION:
PASSENGER SHIPS FOR EVERY 80m, TWO OUTFITS ANDTWO PERSONAL EQUIPMENT
PASSENGER SHIPS >36 PAX, TWO FIRE FIGHTING OUTFITSFOR EACH MAIN VERTICAL ZONE
TANKERS, TWO FIRE FIGHTERS OUTFITS CARGO SHIPS & PASSENGER SHIPS >36 PAX, TWO SPARE
CHARGES FOR EACH BA, OR ONE SPARE CHARGE IF CAPABLEOF BEING RECHARGED AT SEA FOR CARGO SHIPS AND
PASSENGER SHIPS
8/3/2019 4[1].Fire Fighting
23/41
8/3/2019 4[1].Fire Fighting
24/41
8/3/2019 4[1].Fire Fighting
25/41
8/3/2019 4[1].Fire Fighting
26/41
8/3/2019 4[1].Fire Fighting
27/41
8/3/2019 4[1].Fire Fighting
28/41
EMERGENCY ESCAPE
BREATHING DEVIC
ES
EEBD CAN BE USED TO HELP ESCAPE FROM A SPACE WHICHIS FILLED WITH SMOKE OR TOXIC GASES. IT ISLOCATED WHERE IT IS ACCESSIBLE TO ALL. SHIPS NEED
TO CARRY THE FOLLOWING NUMBER OF EEBDS:
ALL SHIPS AT LEAST 2 EEBD WITHIN ACCOMMODATION
IN PASSENGER SHIPS AT LEAST TWO EEBD IN EACH
MAIN VERTICAL ZONE
ADDITIONAL TWO EEBD FOR PASSENGER SHIPS >36 PAX
8/3/2019 4[1].Fire Fighting
29/41
FIXED FIRE DETECTION & ALARM
SYSTEMSTHE PURPOSE OF THIS IS TO DETECT ANY FIRE IN THE SPACE
OF ORIGIN AND TO PROVIDE ALARM FOR SAFE ESCAPE ANDFIRE FIGHTING ACTIVITY. FOR THIS PURPOSE THEFOLLOWING REQUIREMENTS SHALL BE MET:
FIXED FIRE DETECTION AND ALARM SYSTEMS SHALL BESUITABLE FOR THE NATURE OF THE SPACE, FIRE GROWTHPOTENTIAL AND POTENTIAL GENERATION OF SMOKE &GASES
MANUALLY OPERATED CALL POINTS SHALL BE PLACED
EFFECTIVELY TO ENSURE A READILY ACCESSIBLE MEANS OFNOTIFICATION FIRE PATROLS SHALL PROVIDE AN EFFECTIVE MEANS OF
DETECTING AND LOCATING FIRES & ALERTING THENAVIGATION BRIDGE & TEAMS
8/3/2019 4[1].Fire Fighting
30/41
SMOKE DETECTORS SHALL BE INSTALLED IN ACCOMODATION
SPACES, ESCAPE ROUTES, ETC
PASSENGER SHIPS >36 PAX - FIXED FIRE DETECION &ALARM SYSTEMS SHALL BE INSTALLED IN ACCOMODATIONSPACES, SERVICE SPACES, CONTROL STATIONS, ETC EXCEPTIN BATHROOMS, PUBLIC TOILETS, CO ROOMS
PASSENGER SHIPS
8/3/2019 4[1].Fire Fighting
31/41
DONT SLEEP!
8/3/2019 4[1].Fire Fighting
32/41
8/3/2019 4[1].Fire Fighting
33/41
8/3/2019 4[1].Fire Fighting
34/41
PORTABLE FIRE EXTINGUISHERS
THESE SHALL COMPLY WITH THE REQUIREMENTS OF THE FIRESAFETY SYSTEM CODE.
ACCOMODATION SPACES, SERVICE SPACES & CONTROLSTATIONS SHALL BE PROVIDED WITH PORTABLE FIRE
EXTINGUISHERS OF APPROPRIATE TYPE AND IN SUFFICIENTNUMBER REQUIRED BY THE ADMINISTRATION. SHIPS>1000GRT SHALL CARRY AT LEAST 5 PORTABLEEXTINGUISHERS
THESE EXTINGUISHERS SHALL BE PLACED AT THE ENTRANCEOF THE PLACE WHERE IT IS INTENDED TO USE
CO2 EXTINGUISHERS SHALL NOT BE PLACED INACCOMODATION SPACES. IN CONTROL STATIONS ANDOTHER SPACES WHERE THERE ARE ELECTRICAL EQUIPMENTSNECESSARY FOR THE SAFETY OF SHIP, EXTINGUISHERSSHALL BE PROVIDED WHICH ARE NOT ELECTRICALLYCONDUCTIVE OR HARMFUL TO THE EQUIPMENT
8/3/2019 4[1].Fire Fighting
35/41
PORTABLE EXTINGUISHERS SHALL BE PROVIDED WITHDEVICE WHICH INDICATES WHETHER THEY HAVE BEEN USEDOR NOT
THERE SHALL BE ONE PORTABLE FOAM APPLICATOR UNIT ATTHE ENTRANCE OUTSIDE OR IN THE BOILER ROOM. THERESHALL BE AT LEAST TWO SIMILAR EXTINGUISHERS OREQUIVALENT IN EACH FIRING SPACE IN THE BOILER ROOM.THESE EXTINGUISHERS SHALL BE PROVIDED WITH HOSESON REELS
THERE SHALL BE SUFFICIENT FOAM TYPE EXTINGUISHERS
OF AT LEAST 45 LITRES OR EQUIVALENT TO BE DIRECTEDONTO ANY PART OF LUBE OIL PRESSURE SYSTEMS, GEARINGOR OTHER FIRE HAZARDS
IN ADDITION THERE SHALL BE SUFFICIENT NUMBER OFPORTABLE FOAM OR EQUIVALENT EXTINGUISHERS WITHINMACHINERY SPACE SO PLACED THAT NO POINT IN THE
SPACE IS MORE THAN 10m WALKING DISTANCE FROM ANEXTINGUISHER PORTABLE EXTINGUISHERS OF 12kg OF DRY POWDER SHALL
BE PROVIDED IN THE CARGO HOLD SPACES. PORTABLEEXTINGUISHERS SHALL BE PROVIDED AT EACH DECK LEVELIN EACH HOLD, SPACE NOT MORE THAN 20m APART ON BOTHSIDES OF THE SPACE
8/3/2019 4[1].Fire Fighting
36/41
ROUTINE CHECKS &
MAINTENANC
EFIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN
GOOD WORKING ORDER & READILY AVAILABLE FORIMMEDIATE USE. PORTABLE EXTINGUISHERS WHICH HAVEBEEN DISCHARGED SHOULD BE IMMEDIATELY RECHARGED ORREPLACED WITH AN EQUIVALENT UNIT
MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIEDOUT BASED ON THE GUIDELINES DEVELOPED BY THEORGANIZATION AND IN A MANNER HAVING DUE REGARD TOENSURING THE RELIABILITY OF FIRE FIGHTING SYSTEMSAND APPLIANCES. THE MAINTENANCE PLAN SHALL BE KEPT
ON BOARD. IT SHALL INCLUDE AT LEAST THE FOLLOWINGFFA AND SYSTEMS:
FIRE MAINS, FIRE PUMPS AND HYDRANTS, INCLUDINGHOSES, NOZZLES AND INTERNATIONAL SHORECONNECTION
8/3/2019 4[1].Fire Fighting
37/41
FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS
FIXED FIRE EXTINGUISHING SYSTEMS & FFA AUTOMATIC SPRINKLERS, FIRE DETECTION AND FIRE
ALARMS
VENTILATION SYSTEMS, INCLUDING FIRE AND SMOKEDAMPERS, FANS & THEIR CONTROLS
EMERGENCY SHUTDOWN OF FUEL FIRE DOORS, INCLUDING THEIR CONTROLS
EEBD
PORTABLE FIRE EXTINGUISHERS, INCLUDING BA SETS ANDSPARE BOTTLES
FIRE FIGHTERS OUTFIT
CHEMICAL SUITS
8/3/2019 4[1].Fire Fighting
38/41
CHECKS ON FIRE DETECTION SYSTEMS
THE MAINTENANCE SHOULD INCLUDE TESTING: SMOKE DETECTORS USING THE SMOKE SPRAY CANISTERS
INFRA FLAME DETECTORS USING TORCH LIGHT ORCIGARETTE LIGHTERS
HEAT DETECTORS USING HAIR DRYERS
TESTING THE SYSTEM TO ENSURE IT IS FUNCTIONINGNORMALLLY
CHECKS ON CO2 SYSTEM CHECK THE LEVEL OF CO2 BOTTLE EITHER BY WEIGHING OR
THE ISOTOPE METHODS
CHECK THAT ALL THE ALARMS ARE WORKING PROPERLY
CHECK THAT ALL THE CO2 OUTLETS ARE FREE OFOBSTRUCTION
8/3/2019 4[1].Fire Fighting
39/41
CHECKS ON THE FOAM SYSTEM CHECK THAT THE FOAM IS VIABLE BY USING THE TEST KIT
PROVIDED BY THE MAKERS CHECK THAT THE FOAM SPREADERS FROM THE ENGINE ROOM
ARE NOT OBSTRUCTED CHECK THAT THE VALVES ARE GREASED AND NOT CORRODED
OR JAMMED CHECK THAT THE DECK MONITORS ARE GREASED AND EASY
TO ROTATE
CHECKS ON FIRE MAIN, HYDRANTS, HOSES& NOZZLES
THE INSPECTIONS INCLUDE: TESTING THE SYSTEM FOR LEAKS INSPECT PIPES FOR CORROSION OPEN DRAIN VALVES REGULARLY, ESPECIALLY IN COLD
WEATHERS TO AVOID FREEZING OF WATER AND THEREBYCHOKING THE PIPELINES
8/3/2019 4[1].Fire Fighting
40/41
THE VALVES ARE GREASED PROPERLY AND EASY TO MOVE
PRESSURE TESTING HOSES
TESTING SPRAY NOZZLES THROUGH THEIR OPERATINGRANGE
REPLACE DAMAGED PARTS, LIKE BOLTS, COUPLINGS, ETC IFFOUND NON-FUNCTIONAL
ORDER NEW SPARES
CHECKS ON PORTABLE EXTINGUISHERS RECHARGE CYLINDERS ONCE USED
BEFORE RECHARGING CHECK THE CYLINDER FOR CORROSION
CHECK CYLINDER IF DUE FOR PRESSURE TEST
CHECK THE TRIGGER VALVE FLUID IS TIGHT AND OPERATESFREELY
CHECK OPERATION AND FLUID TIGHTNESS OF OTHERVALVES
8/3/2019 4[1].Fire Fighting
41/41
ENSURE SAFETY PIN PUT IN CAP AFTER RECHARGING
WRITE THE DATE OF TEST ON THE LABEL ATTACHED REPLACE CYLINDER IN PREVIOUS POSITION
CHECKS ON FIRE FIGHTERS OUTFIT
ALL OUTFITS ARE LOCATED IN THE CORRECT POSITIONS
THE BATTERY OF THE SAFETY TORCH IS FULLY CHARGED THE BREATHING APPARATUS IS READY FOR USE AND FULLY
CHARGED. IF NOT, RECHARGE
LIFE LINE, FIRE AXE ARE ALL IN PLACE AND NOT DAMAGED
RISE -END- SHINE