Page 1: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4 5 9 0

C o n f i g M a t eU S B C o m m u n i c a t i o n s I n t e r f a c eN o . 4 5 9 0 V 1 0 0 - U KF r o m s e r . n o . 1 1 0 4 0 4 0 0 1

Page 2: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

1346

PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv barske miljøer med elektrisk støj, vibrationer og temperaturudsving, og alle produkter opfylder de strengeste internationale standarder. Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet.

PR electronics A/S offers a wide range of analogue and digital signal conditioning devices for industrial automation. The product range includes Isolators, Displays, Ex Interfaces, Temperature Transmitters, and Universal Devices. You can trust our products in the most extreme environments with electrical noise, vibrations and temperature fluctuations, and all products comply with the most exacting international standards. »Signals the Best« is the epitome of our philosophy – and your guarantee for quality.

PR electronics A/S offre une large gamme de produits pour le traite ment des signaux analogiques et numériques dans tous les domaines industriels. La gamme de produits s’étend des transmetteurs de température aux afficheurs, des isolateurs aux interfaces SI, jusqu’aux modules universels. Vous pouvez compter sur nos produits même dans les conditions d’utilisation sévères, p.ex. bruit électrique, vibrations et fluctuations de température. Tous nos produits sont conformes aux normes internationales les plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne de conduite - et pour vous l’assurance de la meilleure qualité.

PR electronics A/S verfügt über ein breites Produktprogramm an analogen und digitalen Signalverarbeitungsmodule für die in-dustrielle Automatisierung. Dieses Programm umfasst Displays, Temperaturtransmitter, Ex- und galvanische Signaltrenner, und Universalgeräte. Sie können unsere Geräte auch unter extremen Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen und Temperaturschwingungen vertrauen, und alle Produkte von PR electronics werden in Überein stimmung mit den strengsten internationalen Normen produziert. »Signals the Best« ist Ihre Garantie für Qualität!

DK

UK

FR

DE

Page 3: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 1

USB COMMUNICATIONS INTERFACE

CONFIGMATE 4590

CONTENTS

Warning ....................................................................................................... 2Symbol identification ............................................................................ 3Safety instructions ................................................................................. 4Application ................................................................................................. 5Docking Mode ........................................................................................... 5

Connection of ConfigMate 4590 to a PC in Docking Mode ............................................................ 5Connection of ConfigMate 4590 to a PR 4000/9000 Device ...................................................... 6

Adaptor Mode ........................................................................................... 7Connection of ConfigMate 4590 to a PR 3000 Device ..... 8

USB and PReset installation (Docking Mode Only) ................... 8Technical characteristics ...................................................................... 8System requirements ............................................................................ 8Installation of USB driver for Windows® XP ................................. 9Installation of USB driver for Windows® Vista ............................ 12Installation of USB driver for Windows® 7 .................................... 15Installation of PReset ........................................................................... 17

Page 4: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

2 4590V100-IN

WaRnIngThis device is designed for connection to hazardous electric voltages. Ignoring this warning can result in severe personal injury or mechanical damage.To avoid the risk of electric shock and fire, the safety instructions and warnings of this guide must be observed and the guidelines followed. The specifications must not be exceeded, and the device must only be applied as described in the following.Prior to the commissioning of the device, this guide must be examined carefully.Only qualified personnel (technicians) should operate this device. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Repair of the device must be done by PR electronics A/S only.

Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively, PR electronics A/S.

gEnERaL

WaRnIng - RISK OF EXPLOSIOn HaZaRDTo avoid risk of explosion and injury:

•Donotusethisequipmentwhenaflammableorcombustibleatmosphere is present

•Donotreplacebatteriesunlessareaisknowntobesafe.•Use3x1.5VTYPEAAAbatteriesonlyandinsertcorrectly

as stipulated in battery compartment.

EXPLO- SIOn

Page 5: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 3

ELEC-TRICaLSHOCK

WaRnIng - RISK OF ELECTRICaL SHOCKTo avoid risk of electrical shock and injury:

•DonotdisconnectthecablefromConfigMate4590whilecable is connected to a SYSTEM 3000 device.

•Donotremove4501whilethecableisconnectedtoaSYSTEM 3000 device.

•DonotreplacebatterieswhilethecableisconnectedtoaSYSTEM 3000 device.

SyMBOL IDEnTIFICaTIOn

Triangle with an exclamation mark: Warning/demand. Potentially lethal situations. The CE mark proves the compliance of the device with the requirements of the EU directives. The double insulation symbol shows that the device is protected by double or reinforced insulation.

Page 6: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4 4590V100-IN

SaFETy InSTRUCTIOnS

DEFInITIOnSHazardous voltages have been defined as the ranges: 75...1500 Volt DC, and 50...1000 Volt AC.Technicians are qualified persons educated or trained to mount, operate, and also trouble-shoot technically correct and in accordance with safety regulations.Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation.RECEIPT anD UnPaCKIngUnpack the device without damaging it. Check on delivery of the device whether the type corresponds to the one ordered.EnvIROnMEnTAvoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy moisture.

nORMaL OPERaTIOnOnly technicians who are familiar with the technical terms, warnings, and instructions in the manual and who are able to follow these should connect the device. Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively,

PR electronics a/S www.prelectronics.com

CLEanIngWhen disconnected, the device may be cleaned with a cloth moistened with distilled water.

LIaBILITyTo the extent that the instructions in this manual are not strictly observed, the customer cannot advance a demand against PR electronics A/S that would otherwise exist according to the concluded sales agreement.

BaTTERy REPLaCEMEnTReplace batteries with 3 x 1.5V TYPE AAA (not included).

Page 7: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 5

application

The ConfigMate 4590 is a USB communications interface which is used along with the 4501 Programmable Display to configure or document and backup/restore configurations of selected PR electronics’ programmable devices, either standalone in Adaptor Mode or with a PC in Docking Mode.

Docking Mode

• The 4590 can operate as a docking station for the 4501 allowing the 4501 to be connected to a PC through a USB interface. The PReset software can be used to upload and download the configuration parameters from a 4501 for backup/restore and documentation purposes, on selected 3000, 4000 and 9000 series devices.

Please note:

• For connection to a PC the USB-B to USB-A cable must be used

• In docking station mode the 4590 will be powered from the PC’s USB power source; no batteries are required.

• The 4501 display will indicate USB line/communication with a very short blink when uploading or downloading configurations from/to the 4501.

• The selected 3000, 4000 and 9000 device configurations can only be viewed in the Preset software.

Connection of ConfigMate 4590 to a PC in Docking Mode

Page 8: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

6 4590V100-IN

Connection of ConfigMate 4590 to a PR 4000/9000 Device

note:

By default, the Programming Display 4501 will display the desired process value when connected to a device, either directly or via ConfigMate 4590.

• To upload a configuration from a 3000/4000/9000 device to the Programming Display 4501, you must manually go into the Memory Menu of the 4501 and SAVE from the target device into the 4501.

• To download a configuration to a 3000/4000/9000 device from the Programming Display 4501, you must manually go into the Memory Menu of the 4501 and LOAD to the target device from the 4501.

For further details, please refer to the relevant manual for the target device.

Page 9: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 7

adaptor Mode

• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows for configuration and monitoring of process parameters of the installed modules.

• Note for connection to a 3000 series product, the PR USB-B to a 2.5 mm jack cable must be used.

• By pressing the power button, the 4590 will power on, and show the status of the attached 3000 module on the 4501.

• If the 3000 device is powered, the 4501 display will indicate the process variable or can be manually set to go into program mode.

• If the 3000 device is not powered the 4501 display will be in program mode only.

• Indication of battery level is displayed via the LEDs. This can be activated by using the Power/Wake-up button. If while pressing the Power/Wake-up button the LEDs are off, or only one LED is lit, the batteries should be exchanged. To extend battery life the 4590 will automatically detect if it is not in use, and will consequently shut itself down to conserve battery power.

• Battery life in Adaptor Mode is approximately 1 year of daily use, depending upon battery type.

Page 10: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

8 4590V100-IN

Connection of ConfigMate 4590 to a PR 3000 Device

USB and PReset installation (Docking Mode Only)

The USB communication is supported by Windows® 2000, XP, Vista and Windows® 7. PR devices that can either be programmed or have their configurations saved, backedup/restored via ConfigMate 4590 are available in the configuration program PReset ver. 6.0 or higher.

Technical characteristics

The PC program PReset ver. 6.0 or higher supports ConfigMate 4590. To conserve power on a laptop, the USB connector of the 4590 can be connected to an externally supplied hub. The communications connector on the PR device is galvanically isolated from the USB connection on the PC.

System requirementsAccess to internet is needed for installation of USB driversInstallation rightsWindows® 2000, XP, Vista and Windows® 7 with the following recommendations:Hard disk space ............ 25 MBUSB .................................... Version 2.0 or higher

Page 11: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 9

Installation of USB driver for Windows® XP

To install the USB driver:1. Connect ConfigMate 4590 to the USB port of the PC.2. After a short while, the “Found New hardware wizard” will appear. Allow

Windows Update to search for software by selecting “Yes, this time only” followed by “Next”.

3. Allow the Hardware Wizard to automatically install the appropriate software drivers by selecting “Install the software automatically (Recommended)” followed by “Next”.

Page 12: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

10 4590V100-IN

4. The Hardware Wizard will then search for the appropriate drivers.

5. Once the Hardware Wizard finds the USB driver it will be installed automatically.

6. After successful installation, the Hardware Wizard will indicate that it has completed the installation with the following dialogue box.

Page 13: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 11

7. To check installation and allocation of the COM port, open up “Device Manager” and expand the “Ports” and “Universal Serial Bus controller” sections. “USB Serial Port” and “USB Seial Converter” should appear in the sections as highlighted below. The COM port assigned is also highlighted in the “Ports” section. In the example highlighted this was assigned COM4, however this may change from installation to installation. Take a note of which COM port is assigned as this is used later in the PReset software.

Page 14: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

12 4590V100-IN

Installation of USB driver for Windows® vista

To install the USB driver:1. Connect ConfigMate 4590 to the USB port of the PC.2. After a short while, the “Found New Hardware” wizard will be shown.

Select “Locate and install driver software (recommended)”.

3. The Found New Hardware dialogue box will appear. Select “I don’t have a disc. Show me other options”.

Page 15: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 13

4. If Windows does not find a preconfigured driver select “Check for Solution”.

5. Windows will then automatically search for, download and install the appropriate driver.

6. Windows will then install the USB Serial Convertor driver followed by the USB Serial Port driver.

Page 16: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

14 4590V100-IN

7. After successful installation, Windows will indicate that the device is “Ready to use”.

8. Check installation and allocation of the COM port in the “Device Manager” as described in the installation for XP.

Page 17: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 15

Installation of USB driver for Windows® 7

To install the USB driver:1. Connect ConfigMate 4590 to the USB port of the PC.2. After a short while, the “Driver Software Installation” dialogue box can

be viewed. Windows will first automatically search the computer for preconfigured drivers.

3. Windows will then automatically search the internet for appropriate drivers.

4. Windows will then install the drivers for ConfigMate.

5. Windows will then install the USB Serial Convertor followed by USB Serial Port driver.

Page 18: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

16 4590V100-IN

6. After successful installation, Windows will indicate that the device is “Ready to use”.

7. Check installation and allocation of the COM port in “Device Manager” as described in the installation for XP.

Page 19: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 17

Installation of PReset

Before installing PReset, previous versions must first be uninstalled. During the uninstall process there will be an option to save existing configuration files. If this option is not accepted, then these files will be deleted during the uninstall process.

PReset will be installed on your hard disk and the registry will be updated with all necessary information on the program. A PReset icon will automatically be placed on the desk top.

1. Download PReset version 6.0 or later from www.prelectronics.com. Note that this is in the form of a zip file.

2. Unzip the file to the desired location.

3. To start the installation, double click the setup.exe file. When the installation program has been started, on-screen guidelines will guide you through the rest of the installation.

The following is an example of PReset installation on Windows® 7.

Note: To install PReset on Windows 7 it is necessary to be a local administrator on the PC.

Page 20: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

18 4590V100-IN

1. PReset Setup will prepare the Installation Wizard on double clicking setup.exe.

2. Installation Wizard will appear, click “Next” to start the installation.

3. InstallShield Wizard for PReset will appear, press “Next” to continue.

Page 21: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

4590V100-IN 19

4. Read and accept the License Agreement and press “Next” to continue.

5. Chose the destination for the installation and press “Next” to continue.

6. Installation will then be ready to proceed, select “Install” to continue.

7. The installation of PReset will then continue.

8. When installation is complete click “Finish” to exit.

Page 22: 4590 - prelectronics.com...• The 4590 is a handheld device that can operate as an adapter between the 4501 programming front and a selected modules in the 3000 series. This allows

Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software.

Displays

A wide selection of transmitters for DIN form B mounting and DIN rail modules with analogue and digital bus communication ranging from application- specific to universal transmitters.

Temperature

Galvanic isolators for analogue and digital signals as well as HART® signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling of output signals.

Isolation

Interfaces for analogue and digital signals as well as HART® signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.

Ex interfaces

PC or front programmable modules with universal options for input, output and supply. This range offers a number of advanced features such as process calibration, linearisation and auto-diagnosis.

Universal


Recommended