46 Series MAConnect®
Specifications46 Series Valve
Fluids:Compressed Air or Inert Gases
Lubrication:Not required. If used, select a medium aniline point lubricant (between 180ºF and 210ºF)
Safe Operating Temperature Range:0ºF to 120ºF (-18ºC to 50º C)
Pressure Range:Vacuum to 100 PSI
Electrical:DC 12/24 Volt 1.3w to 5.4wAC 24, 120VACMaximum Coil Amperage - 250mAMaximum Voltage - 120VACDielectric Strength in Excess of 2000 Volts.Recommended Mating Sub-D Cable Specifications
3 Amp Current Rating per Conductor300 Volt RMS, 105ºC Insulation
Amp CPC Connector Specifications
Receptacle: (Mounted in MAConnect™ adapter block)
• Series 1 Amp CPC Connector• Shell size 23• 24 Male pins (1.57mm diameter)• Five key configuration
Recommended Plug:
• Amp part number 206837-1• 5 key configuration• Recommended receptacle contacts are size 16 type III+ (Accepts pin dia. 1.57mm)
Additional information can be obtained from Amp Catalog 82021
SpecificationsSM16 Manifold
Outputs:Number: 16 Channels / Solenoids on manifoldVoltage Current: 24 VDC at .225 per channel (5.4 Watts max.)
Inputs: Not available at this time
Protocols :DeviceNet
Current Consumption:Outputs - 4 A Max.Electronics - 200mA
Voltage Ranges:Operating with single supply: 24VDCOperating separate supply for valves : 24VDC
Operating Temperature:0-50º C (32-120ºF)10-90% RH (Non-condensing)
Operating Atmosphere:No corrosive gases
Enclosure:Designed to meet NEMA 4
Impact Resistance:10G
SpecificationsSM32 Manifold
Outputs:Number: 16 Channels / Solenoids on manifoldVoltage Current: 24 VDC at .225 per channel (6.0 Watts max.)
Inputs:Number: 4Type: 24 VDC NPN or PNP Logic
Protocols:DeviceNetAllen Bradley Remote I/O*ProfibusInterbus-SAS-I
Current Consumption:Outputs - 4 A Max.Electronics and Inputs - 75mA
Voltage Ranges:Operating with single supply: 24VDCOperating separate supply for valves : 24VDC
Safe Operating Temperature Range:0-50º C (32-120ºF)10-90% RH (Non-condensing)
Enclosure:Designed to meet NEMA 4 and IP65
* This product incorporates technology which is licensed by Allen-Bradley Company, Inc. Allen-Bradley has not technically approved, nor does it warrant or support this product. All warrantyand support for this product and its application is provided solely by MAC Valves, Inc.
How To Order46 Series MAConnect™
46A - X X X - X X - JXXP - X XX
Solenoid Assembly
Body Type0 Base Only No ValveL Sgl. Sol. Base Mount BodyM Sgl. Sol. Base Mount Body
w/ Gage Port
Commons0 Valve OnlyM Positive CommonsN
Port Size andThread Type
0 Valve OnlyA 1/8” NPTFB 1/8” BSPPLC 1/8” BSPTRF 5/32” Pressed In Tube
Receptacle
Base Electrical0 Valve OnlyA Sgl. Sol. Plug-In to LeftE Sgl. Sol. Plug-In to Right
Configuration0 Valve OnlyC Side CylsD Side Cyls w/ F.C.E Bot. Cyls w/ Reg.
(Slotted Stem)F Bot. Cyls w/ Reg.
(Slotted Stem) & F.C.G Bot. Cyls w/ Reg.
(Locking Slotted Stem)H Bot. Cyls w/ Reg.
(Locking Slotted Stem) & F.C.J Bot. Cyls w/ Reg.
(Adjusting Knob)K Bot. Cyls w/ Reg
(Adjusting Knob) & F.C.L Bottom CylsM Bottom Cyls w/ F.C.
Note: F.C. = Flow Controls
Parts28502 Exhaust Isolator28501 Inlet IsolatorM-46002 Valve Blanking Plate
How To Order46 Series Plug-In Manifold
46A - X X X - X X - JXXP - X XX
Solenoid Assembly
Body Type0 Base Only No ValveL Sgl. Sol. Base Mount BodyM Sgl. Sol. Base Mount Body
w/ Gage Port
Manifold Style0 Valve OnlyS Plug-In (12” Base Leads)
Port Size andThread Type
0 Valve OnlyA 1/8” NPTFB 1/8” BSPPLC 1/8” BSPTRF 5/32” Pressed In Tube
Receptacle
Manifold Wiring0 Valve OnlyA Wired for Sgl. Sol.
Configuration0 Valve OnlyC Side CylsD Side Cyls w/ F.C.E Bot. Cyls w/ Reg.
(Slotted Stem)F Bot. Cyls w/ Reg.
(Slotted Stem) & F.C.G Bot. Cyls w/ Reg.
(Locking Slotted Stem)H Bot. Cyls w/ Reg.
(Locking Slotted Stem) & F.C.J Bot. Cyls w/ Reg. (Adjusting
Knob)K Bot. Cyls w/ Reg
(Adjusting Knob) & F.C.L Bottom CylsM Bottom Cyls w/ F.C.
Note F.C. = Flow Controls
PartsM-46003-01(*) End Plate Kit (One required per stack)28502 Exhaust Isolator28501 Inlet IsolatorM-46002 Valve blanking plate
* P = BSPPL, T = BSPTR, Blank = NPTF
How To Order46 Series Solenoid Assembly
46A - XXX - XX - J XX P - X XX
VoltageAA 120 VAC (5.4w) - Max Cv = 0.3AC 24 VAC (5.4w) - Max Cv = 0.3DA 24 VDC (5.4w) - Max Cv = 0.3DB* 12 VDC (5.4w) - Max Cv = 0.3DC 24 VDC (2.4w)DD 12 VDC (2.4w)DE 24 VC (1.8w)DF 12 VDC (1.8w)DJ 24 VDC (1.3w)DL 12 VDC (1.3w)LA 120 VAC (5.4w) - Max Cv = 0.23LB 24 VAC (5.4w) - Max Cv = 0.23MA 24 VDC (5.4w) - Max Cv = 0.23MB* 12 VDC (5.4w) - Max Cv = 0.23
* Not available for MAConnect®
Note: AC Voltage requires a connectorwith a rectifier
Manual Operator0 No operator1 Recessed Non Locking Operator2 Recessed Locking Operator3 Extended Non Locking Operator4 Extended Locking Operator
Electrical ConnectorFA Base Plug-InFB Base Plug-In with DiodeFC Base Plug-In with MOVFD Base Plug-In with LEDFE Base Plug-In with Diode and LEDFF Base Plug-In with MOV and LEDFG Base Plug-In with RectifierFH Base Plug-In with Rectifier and LED
46 Series MAConnect™How to Order
Adapters / End Plate Kit
MAConnect™ Fastening End Plate KitM-46006 - XX - 01 X
01 Left End of Stack02 Right End of Stack
Leave Blank For NPTF ThreadsP BSPPL ThreadsT BSPTR Threads
MAConnect™ Adapter AssemblyM-46005 - XX - X X
09 9 Pin Sub-D10 10 Pin15 15 Pin Sub-D16 16 Pin20 20 Pin24 24 Pin Amp CPC25 25 Pin Sub-D26 26 Pin
1 Left End2 Right End
Leave Blank for NPTF ThreadsP BSPPL ThreadsT BSPTR Threads
Note: “01” should be used only when the Fastening End Plate Kit is ordered separately. When the kit is ordered with anassembly this number will change to indicate the number of valves in the stack.
Note: For washdown Sub-D connector use MOD 532M after model number.For negative commons, use MOD. 1705 after model number.
ProtocolDN DeviceNet
Output Indicator Lights0 St’d (No Lights)
Bus ConnectorDeviceNet
A 5 Pin Micro
Inputs00 No Inputs
Location ofMAConnect Adapter
0 No Adapter1 Left End2 Right EndAdapter has commoninlet and exhaust ports
Valve SeriesAdapter
00 No Adapter92 92 Series82 82 Series47 47 Series42 42 Series48 48 series32 32 SeriesP1 MV-P1 SeriesP2 MV-P2 Series45 45 Series38 38 Series44 44 Series93 93 Series4646 Series
Thread Type00 No adapterA Int. NPTFB Ext. NPTFC Int. BSPPLD Ext. BSPPLE Int. BSPTRF Ext. BSTPR
How to Order SM16 for MAConnect™
Serial Manifold
SM16 - XX A - X X X - XX M - X X XXMAConnect™
Power ConnectorDeviceNet
A 3 Pin Micro
Revised 9/02
ProtocolDN DeviceNetPB ProfibusIB Interbus-SAB Allen Bradley
Remote IOAS AS-I
Output Indicator LightsMonitoring Valve
SignalA St’d (16)
Monitoring BusLogic Signal
B St’d (16)
ASI Available Only w/(B) Monitoring Signal
Bus ConnectorDeviceNet
A 5 Pin MiniB 5 Pin MicroC 5 Pin Mini
End Mount2 Conn.
ProfibusD 9 Pin Sub-D
Interbus-SE 9 Pin Sub-D
Male &Female
AB Remote IOF 3 Pole Term.G 4 Pin Micro
(2 4-PinConnectors)
AS-IG 4 Pin Micro
2 Conn.H 4 Pin Micro
2 Conn. w/2 Prog. Ports
InputsA No InputsB 1 InputC 2 InputsD 3 InputsE 4 InputsF * Te the re d
16 Inputs8 on AS-I
Location ofMAConnect Adapter
0 No Adapter1 Left End2 Right End
Valve SeriesAdapter
00 No Adapter42 42 Series47 47 Series48 48 Series82 82 Series92 92 Series32 32 SeriesP1 MV-P1 SeriesP2 MV-P2 Series45 45 Series38 38 Series44 44 Series93 93 Series4646 Series
Pilot and Thread Type00 No adapterA Int. NPTFB Ext. NPTFC Int. BSPPLD Ext. BSPPLE Int. BSPTRF Ext. BSTPRN No Pilot Port
82 Series Only
How to Order SM32 for MAConnect™
Serial Manifold
SM32 - XX A - X X X - X X M - X X XX -9MAConnect™
Power ConnectorDeviceNet
A 3 Pin MiniB 4 Pin MiniC 3 Pin MicroE 4 Pin Mini
Side Mount
Profibus &Interbus-S
F 3 Pin MiniH 4 Pin Mini
AB Remote IOG 5 Pole Term.B 4 Pin Mini
AS-ID 4 Pin Micro
Input TypesA No InputsB NPNC PNP
**
**
Revised 9/02
*”F” Option required for remotetethered box or MAConnect inputmodules. Choose option “A” for “InputTypes”
How to OrderInput and Output Modules
Remote Tethered Input Module(For use with SM32 only)N-SM005 - X X X X - XX
Inputs 1-4B NPNC PNP
Inputs 5-80 No InputsB NPNC PNP
Inputs 9-120 No InputsB NPNC PNP
Inputs 13-160 No InputsB NPNC PNP
01 Positive Logic02 Negative Logic
Remote Tethered Output Module(For use with SM16 only)
N-SM006 - X X X X
A Outputs 1-4 0 No OutputsA Outputs 5-8
0 No OutputsA Outputs 9-12
0 No OutputsA Outputs 13-16