MITUTOYO - INDICATORS
4841 W. Chicago Ave. • Chicago, IL 60651 • Ph: 773.261.2182 • Fax: 773.261.2867 • [email protected]
Precision Measuring Equipment and Industrial Supplies since 1924.www.jwdonchin.com
INDICATORS - Cont'dDial Indicators/Group 1 - Inch/Metric R-57~60Dial Indicators/Group 2 - Inch/Metric R-61~68Dial Indicators/Group 3 - Inch/Metric R-69~72Dial Indicators/Group 4 - Inch/Metric R-73~76One-Revolution Dial Indicators - Group 1&2 R-77One-Revolution Dial Indicators - Group 2 R-78Back Plunger w/Perpendicular MountingStem - Group 1 R-79Back Plunger Type Dial Indicators -Group 1 & 2 R-80Hicator - Series 524 R-81, 82Hicator II - Series 524 - Dial Comparator R-83Accessories for Dial Indicators R-84Backs for Dial & Digimatic Indicators R-85, 86Contact Points for Dial & Digimatic Indicators R-87~89Repair Tool Kit, Crystal Setter R-90Dial Gage Stands 7003, Dial Gage Stands withFlat or Grid Anvil R-91Comparator Stands - Series 215 R-92~94Precision Granite Stands - Series 517,Bench Comparators R-95Mini-Magnetic Stands R-96, 97Mini-Magnetic Stands - Series 984,Magnetic Stands R-98Transfer Stands (Heavy Duty Types) -Series 519 R-99Flexi-Stand 7012, Universal MagneticStand 7019 R-100Dial Gage Upright Stand, DigimaticUpright Gage R-101Multi-Stand - Multiple Indicator Stands R-102, 103Quick-Set Gaging System R-104Dial/Digimatic Indicator and Stand Sets R-105Quick Mini - Series 7 R-106Flat Anvil Type R-107, 108Dial Thickness Gages R-109, 110Digi-Test Digimatic Caliper Gages - Series 209 R-111, 112Dial Caliper Gages External Type -Series 209 R-113, 114Dial Caliper Gages Internal Type -Series 209 R-115~117Pocket Thickness Gages - Series 7, Dial TensionGage - Series 546 R-118Snap Gages - Series 201 R-119, 120Truetest Test Indicators - Series 513 R-121"Quick-Set" Test Indicators - Series 513 R-122"Quick-Set" Indicator Dimensions R-123
INDICATORSLitematic - Series 318 R-2, 3All Models of Linear Gage - Display Units(Counters) R-4 ~ 7Laser Hologage R-8LGB/Laser Hologage R-9LGF Series R-10LG/LGM Laser Hologage R-11LGF - Differential Square-wave Output R-12, 13LGB - Differential Square-wave Output R-14, 15LGE - Differential Square-wave Output R-16, 17LGD, LGD-M - Digimatic Code Output R-18, 19LGS - Digimatic Code Output R-20Special Accessories for Gage Head -Air Drive Unit R-21Mu-Checkers - Series 519 - M400 Series R-22Special Accessories for Gage Head R-23Digital Mini-Checker - Series 519 R-24Operational Guide and Tech. Data -Installing the Gage R-25, 26Linear Gage and Counter Connections& Comparisons of Counter Functions R-27EB Counter - Display Unit w/Multiple Limits R-28ES Counter - Assembly Type Display Unit R-29EF Counter - Multi-function Type R-30EV Counter for Multi-gage SystemMulti-function Counter R-31Options for ES/EF/EV Counters R-32IDS Digimatic Indicators w/AbsoluteEncoder - Series 543 R-33, 34IDC Type Digimatic Indicator w/AbsoluteEncoder - Series 543 R-35IDC Digimatic Indicators with AbsoluteEncoder - Series 543 R-36, 37IDC Type Digimatic Indicator w/Abs. Enc. &Peak-Hold - Series 543 R-38IDC-CG Digimatic Indicators w/Abs. Enc. forBore Gage - Series 543 R-39IDU Digimatic Indicator w/Abs Enc. - Series 575 R-40IDF Digimatic Indicator w/Abs Enc. -Series 543 R-41, 42Dial Gage Tester - i-checker - Series 170 R-43, 44Calibration Testers - Series 521, Dial GageTesters - Series 170 R-45Dial Indicators - Group 0/1/2/3/4, Dial IndicatorDial Faces, Order by the Numbers R-46~48Selection Guide for Dial Indicators -Inch/Metric Models R-49, 50Selection Guide for Dial Indicators -Inch/Metric Models R-51, 52Numerical Index for Dial Indicators R-53~55Dial Indicators/Group O - Inch/Metric R-56
LitematicSeries 318
Features• Low constant measuring force
• With a measuring force of 1gf(0.01N), the Litematic is ideal for measuring work pieces that can be easily deformed or that are high-accuracy components
• The Litematic’s motor-driven spindle stops it’s up and down travel when it touches the work piece. Then it allows measurements of maximums, minimums and deflection volumes.
• Measurement with high-accuracy• High-resolution with a minimum indicating value of .0000005"/0.01µm, and a wide measuring range of 2"/50mm.• The measuring table employs ceramics, a material that is rust free, easy to maintain and has a high
wear-resistance.• A low heat-expansion material is used for the spindle unit, in order to minimize deformation caused by
temperature variations.
*Patent registered (JAPAN), Patent pending (JAPAN)
Separate TypeThe measuring unit and the display unit are sepa-rate on the VL-50AS model. This allows the user tointegrate them into his measurement system. Anoptional stand is available.
318-211A(Model VL-50A*)
318-213A(Model VL-50AS*)
LITEMATIC
R-2
NOTE: Shown withoptional stand (957460)
R- 002 (2003) full size 12/9/03 12:06 PM Page 1
SpecificationsLitematic HeadCode No. 318-211A 318-213AModel No. VL-50A VL-50ASMeasuring Range 0" – 2.0" (0-50.8mm)Resolution (selectable) .0000005"/.000005"/.00005" (0.01µm/0.1µm/1.0µm)Display unit Character height .6" (14mm) / 8 digits (excluding "-" sign)Stroke* 2.06" (51.5mm)Accuracy at 20°C (0.5+L/100)µm L=Measuring length (mm)Repreatability* o-=2µinch (0.05µm)Measuring force* 1gf / 0.01NSpindle feed speed
Tracing Approx. .03"/s (0.7mm/sMeasuring Approx. .08"/s (2mm/s) or .16"/s (4mm/s)Quick feed Approx. .3"/s (8mm/s)
Contact point Ø3mm carbide ball (M2.5 x 0.45 thread)Worktable 100mm Ceramic —
(grooved replaceable)Data Input Data can be triggered with the foot switchOutput Digimatic and RS-232CPower Supply 85-264V ACPower consumption 12W (at max)Mass 35.2 lbs. (16kg) 11 lbs. (5kg)Standard accessories AC adapter (357651)
Power cord (930966)Ground wireAllen wrench
Optional accessories Foot switch (937179T)— Dedicated stand (957460)
Output connector (with cover) (02ADB440 ) (for external control)RS-LINK/Digimatic connecting cable (1m) (936937)RS-LINK/Digimatic connecting cable (2m) (965014)
* At normal measurement with the standard contact point.
LITEMATIC
R-3
Dimensions
Interchangeable contact point
318-211A 318-213A 957460
R- 003 (2003) full size 12/9/03 1:04 PM Page 1
All Models of Linear GageGage Heads (Sign wave and Square wave)
Output Measuring Range(Resolution) .2” (5mm) .4” (10mm) 1” (25mm) 2” (50mm)
Laser Hologage
LGB LGF LGF
LGF LGF LGF
LGB LGB
LGE LGE LGE
Laser Hologage
0.25µm pitchSign Wave(1µinch)[0.00001mm]
Square Wave(4µinch)[0.0001mm]
Square Wave(.00002”)*[0.0005mm](.0004”)*[0.001mm]
Square Wave(.00004”)*[0.001mm]
Square Wave(.0002”)*[0.005mm]
*: The resolution shown in inches is a calculated value. The actual resolution in inches is determined by the counter setting.
LINEAR GAGES
R-4
R- 004 (2003) full size 12/9/03 12:24 PM Page 1
Single Function Type Multi-function Type Multi-Gage System4” (100mm)
Display Units (Counters)
KH Counter
EF Counter (High Resolution Type)
ES Counter EF Counter EV Counter
EB Counter
(Not compatible with the LGFwith 0.5mm resolution.)
EV-16P
LG-01100
LGM-01100
LINEAR GAGES
R-5
R- 005 (2003) full size 12/15/03 11: 33 AM Page 1
All Models of Linear GageGage Heads (Digimatic Output)
Output Measuring Range(Resolution) .2” (5mm) .4” (10mm) 1” (25mm) 2” (50mm)
LGD LGD LGD
LGD-M
LGS
Digimatic Outputwith an absolute sensor[.0005”/0.01mm]
Digimatic Outputwith an incremental sensor[.0005”/0.01mm]
LINEAR GAGES
R-6
R- 006 (2003) full size 12/15/03 11: 34 AM Page 1
Single Function Type Multi-function Type Multi-Gage System4” (100mm)
Display Units (Counters)
ES Counter SD Counter EV Counter
SD Counter EB Counter
SD-D1
EV-16D
SD-D2
LINEAR GAGES
R-7
R- 007 (2003) full size 12/15/03 11: 36 AM Page 1
Order No. 542-923A 542-924AResolution .000001" (0.00001mm)Range .4" (10mm)Accuracy (20°C) 0.1µmRepeatability (2σ) 0.02µmMeasuring force Upward ( ) 0.55N or less 0.1N
Horizontal ( ) 0.45N or less —Downward ( ) 0.35N or less —
Dust/Water protection level Not specifiedContact point R5mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm)Stem diameter Ø.59" (15mm)Bearing type High-precision linear ball bearingPosition-detection sensor Laser-hologram measuring sensorMax. response speed 9.84" (250mm)/sOutput signal 0.25µm pitch, 90° phase difference, two-phase sine waveDisplay 8-digit fluorescent tubes and a [-] signFunctions Zero-set, preset, halved reading, double reading (diameter display), ABS/INC coordinate
switching, counting direction switching, mm/inch conversion, linear error compensation, error alarmData output Via RS-232C interface (provided)Power supply 100-120V/200-240V AC, 50/60HzPower consumption Approx. 30VAOperating environment 10°C to 30°C (20%RH to 80%RH, without condensation)Mass Laser Hologage: 0.2kg (excluding cable) Display unit: 2kg.Standard accessories Wrench for contact point (538610)
Laser Hologage0.00001mm (0.01µm) Reading
Display unit isprovided
Features• Highly accurate measurement due to an ultra-high
resolution of 0.00001mm (0.01µm), which is close to theperformance of laser interferometers.
• Excellent measuring stability — the design is also highly resistant to unfavorable environmental conditionssuch as air movement and atmospheric pressure changes.
• High-precision linear ball bearings are used in the guide forextremely smooth movement and exceptional durability.
• A display unit is provided.
Order No. Description09CAA335 Zero-set remote controller971751 Stem fixture for Laser Hologage971752 Stem fixture for Laser Hologage971753 Spindle lifting cable for Laser Hologage971750 Laser Hologage stand
Optional Accessories
542-923
1.79" (45.4)
3.35
" (8
5)
5.75
" (1
46)
0.01
µm ty
pe
.98"
(25)
.39"
(10
) M
easu
ring
rang
e
.39" (10)
.79" (20)
Ø15h6
1.57" (40)
0-0.011
3.94" (100)
AA inchinchmm
Emm
EØØ
UNIT
P.SETZERO
/ 2
AI
LOAD
KH
4.21
" (1
07)
9.25" (235)
.31" (8)
.2" (5) .51" (13)
1
Unit: inch (mm)
Display Unit
Connector for lifting cable
(Stem dia.)
0.01mm type with R5 carbide point.71"
(18)
Dimensions
Specifications
LINEAR GAGES
R-8
R- 008 (2003) full size 12/9/03 12:28 PM Page 1
LGB/Laser Hologage0.0001mm (0.1µm) Reading Differential Square-wave Output
Features• A linear ball bearing in the spindle guide provides
excellent durability for an extended service life.
• The 0.0001mm reading type LGB linear gage (542-246)comes with a clamping nut on the stem.
Order No. Description902434 Extension cable (5m) for LGB902433 Extension cable (10m) for LGB902432 Extension cable (20m) for LGB238773 Rubber boot for LGB (spare)971751 Stem fixture for Laser Hologage971752 Stem fixture for Laser Hologage971753 Spindle lifting cable for Laser Hologage971750 Laser Hologage stand
Optional Accessories
Connecting cable (2m)
1.18"(30)
3.26
" (8
2.7)
.80"(20.4)
Ø.35" (9).71"(18)
Ø.55" (14)
Ø.37"(9.5) 0
-0.009
2.95
" (7
5)
.25"(6.3)
.63"
(15.
9)
.99"(25.1)
.20"
(4.
9) th
read
(HIROSE)RM12BPG-6P
(No.200365)Clamping nut
L
L=.45 (11.5)~.51 (13.0)1.79" (45.4)
0.1µm type with R1.5 carbide point
Connector for lifting cable
Stem dia
3.35
" (
85)
5.84
" (1
48.3
) 0.
1µm
type
.98"
(25)
3.9"
(10
) M
easu
ring
rang
e
.20 (5) Measuring range
.39" (10)
.79" (20)
Ø15h6
.71"(18)
1.57" (40)
0-0.011
Unit: inch (mm)
Ø.3
5" (
9)
Dimensions
Specifications
*1: Only one laser hologage may be connected to the EF counter.To connect two gages, use a 542-062-1 (without AC adapter) and an external power supply (12 to 24 VDC, 1A or greater).
*2: The signal output uses a special pitch (intervals) of0.25mm. The values are converted to 0.0001mmresolution on the counter side.
542-246542-711
LINEAR GAGES
R-9
Model No. LGB Laser Hologage *1
Order No. 542-246 542-711 542-712Resolution .000005" (0.0001mm)Range .20" (5mm) .39" (10mm)Accuracy (20°C) 0.8µm 0.2µmMeasuring force Upward ( ) Approx. 0.65N or less 0.55N or less 0.1N
Horizontal ( ) Approx. 0.6N or less 0.45N or less —Downward ( ) Approx. 0.55N or less 0.35N or less —
Dust/Water protection level IP-54 Not SpecifiedContact point R1.5mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm)Stem diameter Ø.37" (9.5mm) Ø.59" (15mm)Bearing type Linear ball bearing High-precision linear ball bearingPosition-detection sensor Transmission-type photoelectric linear encoder Laser-hologram measurement sensorMax.Response Speed 14.96" (380mm)/sec 9.84" (250mm)/secOutput signal 0.4µm pitch, 90° phase difference, 0.25µm pitch, 90° phase difference,
differential square wave differential square wave (RS-422A equivalent) (RS-422A equivalent)*2
Cable length 2mPower supply +5V ± 5% (power-supply ripple 200 mV p-p max.)Power consumption 150mA 300mAOperating environment 10°C to 30°C (20%RH to 80%RH, without condensation)Mass 160g 200g (excluding cable)Compatible counter EF counter with 0.0001mm resolution.Standard accessories Wrench for contact point (538610) Wrench for contact point (538610)
Wrench for the nut (200168)Remarks with a clamping nut on the stem Low force type
R- 009 (2003) full size 12/9/03 12:28 PM Page 1
Order No. 542-144 542-145Resolution 0.0001mmMeasuring range .39" (10mm) .98" (25mm)Accuracy (20°C) (0.8 + L150)µmMeasuring force Upward ( ) 1.2N or less 4.6N or less
Horizontal ( ) 1.1N or less 4.3N or lessDownward ( ) 1.0N or less 4.0N or less
Dust/water protection*2 IP-66 equivalentContact point Ø.12" (3mm) carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312Stem diameter Ø.31" (8mm) Ø.59" (15mm)Bearing type Stroke ball bearingPosition-detection method Transmission-type photoelectric linear encoderResponse speed*1 59.06" (1500mm)/secOutput signal 90° phase difference, differential square wave (RS-422A equivalent);
minimum edge intervals 500 ns for 1 µm model, 250 ns for 0.5 µm modelSignal pitch 2µmCable length 2mPower supply Supply voltage +5V (4.8V to 5.2V), ripple voltage 200mV p-p max.Power consumption Max. 120mAOperating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass 250g 290gStandard accessories Wrench for contact point (538610) Wrench for contact point (210187)
LGF0.0001mm (0.1µm) Reading Differential Square-wave Output
Order No. Description902434 Extension cable (5m)902433 Extension cable (10m)902432 Extension cable (20m)238772 10mm rubber boot (spare)962504 25mm rubber boot (spare)02ADB680 Thrust stem set (for 10mm LGF model)02ADB690 Thrust stem set (for 25/50mm LGF model)
Optional Accessories .55"(14)
Cla
mpi
ng n
ut fo
r th
rust
ste
mM
9.5x
0.5
Cla
mpi
ng n
ut
for
thru
st s
tem
1.44" (36.5)1.59" (40.5)
2.26" (57.5)
.24"(6)
.48"(12.3)
.79"
(20
)
.68"
(1
7.3)
.22" (5.6)
.58" (14.8)
.42"
(10
.6)
or
long
er s
trok
e
0.023" (0.6)screw top height)
0.023" (0.6)screw top height)
.44" (11.2)
2.99
" (7
5.9)
.26"
(6.7
) 5.06
" (
128.
5)
1.34"(34)+1
0
Ø.31"(8)
0-0.009
M14
x0.5
1.48" (37.6)2.15" (54.6)
.25" (6.4)
.14"(3.5)
1.48"(10.86)
.94"(24.5)
1.02
" (2
6) o
r lo
nger
7.96
" (2
02.1
)
.79" (20)
4.29
" (1
09)
.85"
(21.
5)
.39"(8.6)
.54"(13.8)
0-0.015Ø.59"
(15)
Unit: inch (mm)
3.26" (82.7)
1.18"(30)
.80"(20.4)
2m Cable
.90"
(23
)
1.34"(34)+1
0
.79"(20)
.24"(6)
Dimensions
Specifications
NEW LGF SERIES with 0.1µm resolution for high readability
542-145LGF-0125L
*1: An alarm signal is output when the spindle’s movement speed reaches 1500mm/s. If a Mitutoyocounter is used, an error will be displayed. If the counter is not a Mitutoyo model, contact us regardingthe use of alarm-signal output. When the LGF-150L is used, releasing the contact point after pushing itin may cause an overspeed error depending on the extent to which the contact point is pushed inward.
*2: The IP value is a standard indicating the degreeof protection against solid foreign matter andwater. Note that the standard may not apply tocertain types of liquids.
LINEAR GAGES
R-10
R- 010 (2003) full size 12/9/03 12:29 PM Page 1
Type Standard Type Motor Drive TypeOrder No. 542-312 542-313Resolution 0.1µmMeasuring range 3.94" (100mm)Accuracy (20°C) 2.5µmMeasuring force Upward ( ) 8N or less Set up with motor drive
Horizontal ( ) 6.5N or less Set up with motor driveDownward ( ) 5N or less Set up with motor drive
Dust/water protection IP-54 equivalent*Contact point Ø.12" (3mm) carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312Stem diameter Ø.79" (20mm)Bearing type Ball bearingPosition-detection method Transmission-type photoelectric linear encoderResponse speed 15.75" (400mm)/secOutput signal 90° phase difference, differential signal square wave (RS-422A equivalent);
minimum edge intervals 200 nsSignal pitch 0.4µmCable length 2mOperating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass 640g 780g
LG/LGM Laser Hologage0.0001mm Reading, Long Stroke Type (100mm)
Differential Square-wave Output
Motor Drive Unit – use for control of LGM-01100 spindle
Specifications
Dimensions
542-313LGM-01100Motor drive type
* The IP value is a standard indicating the degree of protection against solid foreign matterand water. Note that the standard may not apply to certain types of liquids.
Work specificationSpindle back speed 2.36" (60mm)/sSpindle forward speed 1.18" (30mm)/s (low speed)
2.36" (60mm)/s (high speed)Measuring force Set up with switchDimensions (W x D x H) 3.54 x 6.89 x 2.91" (90 x 175 x 74mm)External output signal Back for spindle / Forward for spindleExternal output signal Stop signal at upper end for spindlePower supply AC100 to 200VMass 830g
RM12
BPG-
6POu
tput
Cab
le 2
m
2-4.
5 dr
ill a
nd ø
9 co
unte
rsin
king
dep
th 5
33
34
17
ø6
49
50
13
417.
5
Stro
ke 1
02m
m P
lus
191.
56
0-0.013ø20
736
232
73
Outp
ut c
able
=2m
Driv
e ca
ble=
2m
RM12
BPG-
6P
HR10
A-7P
-6P
13
50
619
1.5
Stro
ke 1
02m
m P
lus
ø6
417.
5
17
34
49 33
736
232
73
2-4.
5 dr
ill a
nd ø
9 co
unte
rsin
king
dep
th 5
0-0.013ø20
LINEAR GAGES
R-11
LG-01100Standard type
LGM-01100Motor drive type
R- 011 (2003) full size 12/9/03 12:29 PM Page 1
.55"(14)
Cla
mpi
ng n
ut
for
thru
st s
tem
M14
x 0
.5
1.44" (36.5)1.59" (40.5)
2.26" (57.5)
.24" (6).48" (12.3)
.79"(20)
.68"(17.3) .22" (5.6)
.58" (14.8)
.42" (10.6) or longer (stroke)
1.54
" (3
9)
0.023" (0.6)screw top height
.44" (11.2)
2.99
" (7
5.9)
.26"
(6.7
)5.
06"
(128
.5)
RM12BPG-6P(HIROSE)
Connecting cable 2m
1.34"(34)+1
0
Ø.31"(8)
0-0.009
Ø.71" (18)
1.48" (37.6)2.15" (54.6)
.25" (6.4).14"(3.5)
.43" (10.86)
1.02" (26)or longer (stroke)
7.96
" (2
02.1
)
.79" (20)
4.29
" (1
09)
.85"
(21.
5)
.34"(8.6)
.54"(13.8)
0-0.015
Ø.59"(15)
1.99"(50.5)
12.2
2" (
310.
4)
6.65
" (1
68.9
)1.
15"
(29.
1)
Unit: inch (mm)
.91"(23)
.24"(6)
.96"(24.5)
1.34"(34)+1
0
0.023" (0.6)screw top height
.79"(20)
.25" (6.4).14"(3.5)
2.15" (54.6)1.48" (37.6)
1.34"(34)+1
0
0.023" (0.6)screw top height
.43" (10.86).79" (20)
.79"(20)
0-0.015
Ø.59"(15)
.24"(6)
.54"(13.8)2.03" (51.5)
or longer (stroke)
.34"(8.6)
Cla
mpi
ng n
ut
for
thru
st s
tem
M14
x 0
.5
Cla
mpi
ng n
ut
for
thru
st s
tem
M9.
5 x
0.5
1.34"(34)
8P connectorPRCOS-P8M
Connecting cable 2m
Ø.66"(16.7)
Ø.24"(6.2) LGF with
reference mark
LGF0.0005/0.001mm Reading
Differential Square-wave Output
Features• Excellent structure of protection against dust and water
splash (IP-66) in harsh shop-floor environments.
• Output differential square wave signals for a wide range of applications.
• Use linear stroke bearings on the spindle movement fordurability.
• Thrust Stem with a clamping nut is optional.
Order No. Description902434 Extension cable (5m)902433 Extension cable (10m)902432 Extension cable (20m)238772 10mm rubber boot (spare)962504 25mm rubber boot (spare)02ADB680 Thrust stem set (for 10mm LGF model)02ADB690 Thrust stem set (for 25mm/50mm LGF model)
Optional Accessories
542-121/131
Dimensions
542-122/132
542-123/133
LINEAR GAGES
R-12
R- 012 (2003) full size 12/9/03 12:30 PM Page 1
LGF0.0005/0.001mm Reading
Differential Square-wave Output
542-124* 542-134* 542-125* 542-135* 542-126* 542-136*Order No. 542-121 542-131 542-122 542-132 542-123 542-133Resolution 0.001mm 0.0005mm 0.001mm 0.0005mm 0.001mm 0.0005mmRange .4" (10mm) .98" (25mm) 1.97" (50mm)Accuracy (20°C) (1.5 + L/50) µm (L=mm)Measuring force Upward ( ) 1.2N or less 4.6N or less 5.7N or less
Horizontal ( ) 1.1N or less 4.3N or less 5.3N or lessDownward ( ) 1.0N or less 4.0N or less 4.9N or less
Dust/Water protection2 IP-66 equivalentContact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312Stem diameter Ø.31" (8mm) Ø.59" (15mm)Bearing type Stroke ball bearingPosition-detection method Transmission-type photoelectric linear encoderResponse speed1 59.06" (1500mm)/sOutput signal 90° phase difference, differential square wave (RS-422A equivalent);
minimum edge intervals 500 ns for 1 µm model, 250 ns for 0.5 µm modelSignal pitch 4µm 2µm 4µm 2µm 4µm 2µmCable length 2mPower supply Supply voltage +5V (4.8V to 5.2V), ripple voltage 200mV p-p max.Power consumption Max. 120mAOperating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass 250g 290g 380gStandard accessories Wrench for contact point (538610) Wrench for contact point (210187)
Specifications
1: An alarm signal is output when the spindle’s movement speed reaches 1500mm/s. If a Mitutoyo counter is used, an error will be displayed.If the counter is not a Mitutoyo model, contact us regarding the use of alarm-signal output. When the LGF-150L is used, releasing the contact point after pushing it inmay cause an overspeed error depending on the extent to which the contact point is pushed inward.
2: The IP value is a standard indicating the degree of protection against solid foreign matter and water. Note that the standard may not apply to certain types of liquids.
*with reference mark.
LINEAR GAGES
R-13
R- 013 (2003) full size 12/9/03 12:30 PM Page 1
(HIROSE)RM12BPG-6P
Connecting cable (2m)
1.18"(30)
3.26
" (82
.7)
.80"(20.4)
fl.55" (14)fl.37" (9.5)
.25"(6.3)
.63"
(15.
9)
1.9" (4.9)thread
No.200365Clamping nut
L
L = .45" (11.5)to .51" (13.0)
fl.35" (9)
.71" (18)
fl.35"(9)
2.95
" (7
5)
0-0.009
0-0.009
fl.17" (4.2)
fl.31" (7.9)
Knurl
fl.47" (12)
4.45
" (11
3)
No.200365
1.98
" (50
.3)
4.45
" (11
3)
.18" (4.5)
.63"
(15.
9)
1.15"(29.3)
Applicable air hose(ID fl2.5)
2.37
" (60
.1)
1.55
" (39
.3)
4.02
" (10
2)
.83"(21.2)
.61"
(15.
4)
.94"(23.9)
Stroke .41" (10.5mm)
or longer
.38" (9.6)
Air inlet(Applicable air hose: ID fl2.5)
542-230
.19"(4.9)
.36" (9.2)
Unit:: inch (mm)
Clamping nut
Clamping nut(No.200365)
Knurl
fl.31"(8)
.29"(7.3)
.97"(24.6)
.35"(9)
2.95
" (7
5)
.99"(25.1)
fl.35" (9)
.71" (18)
fl.35" (9)
L = .45" (11.5)to .51" (13.0)
fl.55" (14)fl.37" (9.5) 0
-0.009
1.9" (4.9)thread
1.37"(34.9)
L
.63"
(15.
9).80"
(20.2)
0-0.009
fl.31"(8)
.29"(7.3)
1.37"(34.9)
.61"(15.4)
4.45
" (1
13)
.41"(10.5)
.20"(5)
0-0.009
fl.31"(8)
L = .45" (11.5)to .51" (13.0)
L
2.37
" (60
.1)
fl.37" (9.5) 0
-0.009
Stroke .41" (10.5mm)
or longer
*Connector dimensions are common to all models
542-204542-204H
Dimensions
LGB0.001mm Reading
Differential Square-wave Output
542-244
542-222542-222H542-224
542-262542-262H542-264
542-223
542-270
LINEAR GAGES
R-14
R- 014 (2003) full size 12/9/03 12:31 PM Page 1
Individual specificationsOrder No. 542-204 542-204H 542-222 542-222H 542-224 542-230 542-223
Stem 8mm diameter, straight stem
Order No. 542-244 542-262 542-262H 542-264 542-270
Stem 9.5mm diameter, straight stem with nut
Measuring range .2” (5mm) .4” (10mm)
Accuracy (20°C) 2 µm 1 µm 2 µm 1 µm 2 µm
Measuring Upward ( ) 0.65N or less 0.8N or less 0.6N or less 0.8N or less
force Horizontal ( ) 0.6N or less 0.75N or less 0.55N or less 0.75N or less
Approx. Downward ( ) 0.55N or less 0.7N or less 0.5N or less 0.7N or less
Mass 145g 145g 150g 150g 150g 165g 165g(542-204) (542-222) (542-222H) (542-224) (542-230)
160g 170g 170g 170g 170g(542-244) (542-262) (542-262H) (542-264) (542-270)
Spindle becomes Spindle retreatsAir-lifter mechanism None free when air when air
is supplied is supplied
Resolution 0.001mm
Dust/water protection IP-54
Contact point Ø3mm in carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Bearing type Stroke ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed 900mm/sec
Output signal/signal pitch 4µm pitch, 90° phase difference, differential square wave (RS-422A equivalent)
Cable length 2m
Power supply Supply voltage: 4.8 to 5.3V, ripple voltage 200mV p-p max.
Power consumption 80mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Required air-pressure range 0.3 to 0.4 MPa (3 to 4kg/cm2) (Required only for models equipped with air lifters)
LGB0.001mm Reading
Differential Square-wave Output
Common specifications
LINEAR GAGES
R-15
Features• Extremely compact design. Available with an outside diame-
ter as small as 8mm.
• The small photoelectric linear encoder assures high preci-sion over the entire stroke range.
• The ball bearings used in the spindle unit ensure superbdurability.
R- 015 (2003) full size 12/9/03 12:32 PM Page 1
Features• With a rubber boot for use in harsh environments.
• Optional thrust stem and tightening nut facilitate setup ofthe LGE linear gage in holes of a plate or fixture.
542-601
Dimensions
LGE0.005mm Reading
Differential Square-wave Output
542-604
542-602
542-603
Order No. Description238772 10mm rubber boot (spare)962504 25mm rubber boot (spare)962505 50mm rubber boot (spare)02ADC730 Ø9.5mm Thrust stem set
(for 10mm LGE model)02ADC740 Ø18mm Thrust stem set
(for 25mm/50mm LGE model)
Optional Accessories
LINEAR GAGES
R-16
R- 016 (2003) full size 12/9/03 12:32 PM Page 1
Order No. 542-601 542-604 542-602 542-603
Resolution 0.005mm (5µm)
Measuring range .4” (10mm) 1” (25mm) 2” (50mm)
Accuracy (20°C) 20µm 30µm
Measuring Upward ( ) 1.2N or less 4.6N or less 5.7N or less
force Approx. Horizontal ( ) 1.1N or less 4.3N or less 5.3N or less
Downward ( ) 1.0N or less 4.0N or less 4.9N or less
Dust/water protection1 IP-66 equivalent IP-54 equivalent IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm Ø15mm
Bearing type Stroke ball bearing
Position-detection method Capacitance-type incremental linear encoder
Response speed2 Static: 1400mm/s Dynamic: 17.5mm/s
Output signal/signal pitch 20µm pitch, 90° phase difference, differential square wave (RS-422A equivalent)
Output cable length 2m
Power supply Supply voltage 5V (4.8V to 5.2V), ripple voltage 200mV p-p max.
Power consumption 100mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Lifter mechanism None Built-in air lifter3 None
Mass 200g 220g 250g 300g
Accessories Wrench for contact point (538610) Wrench for contact point (210187)
LGE0.005mm Reading
Differential Square-wave Output
Specifications
1: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
2: Static - The maximum movement speed at which no overspeed error occurs.Dynamic - The maximum movement speed at which measurement by scanning is possible.
3: The air-supply pressure for 524-604 is 0.3 to 0.4 MPa. The spindle moves forward (becomes free) when air is supplied.Use an air hose with an inside diameter of 2.5mm.
LINEAR GAGES
R-17
R- 017 (2003) full size 12/9/03 12:33 PM Page 1
Features• The use of an absolute scale in the sensor
makes it possible to maintain the origin setting even when the power is switched off.
• Special linear ball bearings are used for thespindle guide to ensure a long service life.
• Optional thrust stem and tightening nut facilitate setup of the LGD linear gage inholes of a plate or fixture.
Order No. Description238772 Spare rubber boot (for 10mm LGD model)962504 Spare rubber boot (for 25mm LGD model)962505 Spare rubber boot (for 50mm LGD model)02ADC730 Ø9.5mm Thrust stem set
(for 10mm LGD model)02ADC740 Ø18mm Thrust stem set
(for 25mm/50mm LGD model)965275■■* Digimatic Power Supply Unit
Optional Accessories
Dimensions
Specifications
The dimensions of the LGD is the same as that of the LGE, as indicated on the page at left.The only differences are theshape and size of the connectorat the end of the cable.
575-321/331: Refer to 542-601575-322/332: Refer to 542-602575-323/333: Refer to 542-603575-324/334: Refer to 542-604
Order No. 575-321 575-331 575-324 575-334 575-322 575-332 575-323 575-333Resolution 0.01mm .0005" 0.01mm .0005" 0.01mm .0005" 0.01mm .0005"Measuring range 10mm 0.4" 10mm 0.4" 25mm 1.0" 50mm 2.0"Accuracy (20°C) 20µm .001" 20µm .001" 20µm .001" 30µm .0012"Measuring Upward ( ) 1.2N or less 4.6N or less 5.7N or lessforce Approx. Horizontal ( ) 1.1N or less 4.3N or less 5.3N or less
Downward ( ) 1.0N or less 4.0N or less 4.9N or lessDust/water protection1 IP-66 equivalent IP-54 equivalent IP-66 equivalentContact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312Stem diameter Ø8mm Ø15mmBearing type Stroke ball bearingPosition-detection method Capacitance-type absolute linear encoderResponse speed Unlimited; measurement by scanning cannot be performedOutput signal Digimatic outputExternal input Origin-setting signal (absolute positional origin can be changed externally)Output cable length 2mPower supply Supply voltage 5V (4.5V to 5.5V), ripple voltage 200mV p-p max.Power consumption 20mAOperating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Lifter mechanism None Built-in air lifter2 NoneMass 200g 220g 250g 300gStandard accessories Wrench for contact point (538610) Wrench for contact point (210187)
1: The IP value given is for water. Note: that the unit may not be able to maintain resistance to certain types of liquids.
*: ■■ is left blank or an appropriate suffix (A or E) is inserted, depending onthe AC supply voltage (blank - 100V; A - 120V; E - 240V).
LGD.0005"/0.01mm Reading
Digimatic Code (SPC) Output
.79" (20) .34" (8.6)
1.46
" (3
7)Unit: inch (mm)
575-323/333
575-321/331
575-322/332
575-324/334
2: The air-supply pressure for 575-324 and 575-334 is 0.3 to 0.4 MPa.The spindle moves forward (becomes free) when air issupplied. Use an air hose with an inside diameter of 2.5mm.
LINEAR GAGES
R-18
R- 018 (2003) full size 12/15/03 11: 37 AM Page 1
Features• The use of an absolute scale in the sensor makes it
possible to maintain the origin setting even when the power is cut off.
• The spindle is supported at both ends, improving the accuracy to 15mm.
575-325
Dimensions
SpecificationsOrder No. 575-325 575-335Resolution 0.01mm .0005”Measuring range 10mm .4”Accuracy (20°C) 15µm .0006”Measuring force Upward ( ) 2.0N or less
Horizontal ( ) 1.8N or lessDownward ( ) 1.6N or less
Dust/water protection* IP-66 equivalentContact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312Stem diameter Ø8mmBearing type Slide-bearing typePosition-detection method Capacitance-type absolute linear encoderResponse speed Unlimited; measurement by scanning cannot be performedOutput signal Digimatic outputExternal input Origin-setting signal (absolute positional origin can be changed externally)Output cable length 2mPower supply Supply voltage: 5V (4.5V to 5.5V), Ripple voltage: 200mV p-p max.Power consumption 20mAOperating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass 182g Standard accessories Wrench for contact point (538610)*: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
LGD-M.0005"/0.01mm Reading
Digimatic Code (SPC) Output
Order No. Description02ACA376 Spare rubber boot965275■■* Digimatic Power Supply Unit
Optional Accessories
*: ■■ is left blank or an appropriate suffix (A or E) is inserted, depending onthe AC supply voltage (blank - 100V; A - 120V; E - 240V).
LINEAR GAGES
R-19
R- 019 (2003) full size 12/9/03 12:34 PM Page 1
575-301
Dimensions
Specifications
LGS.0005"/0.01mm Reading
Digimatic Code (SPC) Output
Order No. Description238774 Spare rubber boot903594 Air drive unit (for 575-301 and 575-302)903598 Air drive unit (for 575-311 and 575-312)
Optional Accessories
Note: Inch gage has a stem of 3/8"DIA. (Tol. +0/-.001") and #4-48UNF threads for the contactpoint mount.
Order No. 575-301 575-302 575-311 575-312
Resolution 0.01mm .0005”
Measuring range 12mm .5”
Direction (UP) plus minus plus minus
Accuracy (20°C) 0.02mm .001”
Measuring force Upward ( ) Approx. 1.96N or less
Horizontal ( ) Approx. 1.67N or less
Downward ( ) Approx. 1.47N or less
Dust/water protection1 IP-66
Contact point Ø3mm carbide (mounting Ø5/32” (DIA) steel (4-48UNF)threads: M2.5 (P = 0.45) X 5mm)
Maximum response speed 1600mm/s; measurement by scanning cannot be performed
Stem diameter Ø8mm Ø9.52mm (.375”)
Bearing type Slide-bearing type
Position-detection method Capacitance-type incremental linear encoder
Output signal Digimatic output
Power supply DC5 to 10V (5mA max.)
Cable length 2m
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 170g (including cable)1: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
LINEAR GAGES
R-20
R- 020 (2003) full size 12/9/03 12:36 PM Page 1
Special Accessories for Gage HeadAir Drive Unit
Features• Ascends or descends the spindle of a Linear Gage by
the supply and exhaust of air.
• Spindle descending speed can be adjusted by using thespeed controller of the drive unit.
• Automatic measurement is possible by using a solenoid valve.
Dimensions
Specifications
A B C D E
02ADE250 1.0" 1.18" 3.06" 1.63" 4.35"(25.5) (30) (77.6) (41.5) (110.5)
02ADE270 2.0" 1.97" 3.78" 2.62" 6.28"(51) (50) (95.9) (66.5) (159.5)
903594 02ADE230
02ADE250/02ADE270
LINEAR GAGES
R-21
Order No. 903594 903598 02ADE230 02ADE250 02ADE270
Stroke 10mm .4” 10mm 25mm 50mm
Applicable gage model LGS LGF, LGE, LGD
Air supply 0.49MPa 0.2 to 0.4MPa
Air hose to be used Inner diameter : Ø2.5mm
Mass 60g 150g 250g 300g
R- 021 (2003) full size 12/9/03 12:36 PM Page 1
Mu-CheckersSeries 519 – M400 Series for High Accuracy Millionths/Microns
Mitutoyo M400 Analog Mu-CheckersFeatures• Available in STANDARD and DIFFERENTIAL models.• The operator can select either the INCH or METRIC
mode.• “ZEROSET” features allows the operator to quickly
and accurately reset the indicator for the next applica-tion in either measuring/inspecting modes.
• All controls are easy to reach including the range selector.
• All analog units can output digital data via an optional RS-232C interface.
• Uses Mitutoyo cartridge and lever-type indicators.
Mitutoyo M400 Digital Mu-CheckersFeatures• Available in DIFFERENTIAL and LIMIT models.• Digital Mu-checkers offer easy-to-read digital displays
and electronic data output to a wide variety ofMitutoyo Digimatic Mini-processors for data recordingand Statistical Process Control applications.
• The operator can select either the INCH or METRICmode.
• All controls, including “ZEROSET” are easy to reach.• Probe linearity is set using master or optional gage
block.
519-412A 519-414A
519-402A 519-404A
Gage Head A Gage Head B
Gage Head A
Gage Head BGag
e H
ead
A
Gag
e H
ead
B
A - BA - BA + B
ApplicationExamples
DifferentialMeasurements
Under the Differential Mode, Gage Head A, B, A + B, or A - B can be independently shownon the scale.Specifications
Analog Mu-CheckersInch/MetricOrder No. Style Range Resolution Remarks
519-402A Standard type ±.05"/±1500µm .001"/50µm •Accuracy: ±1% Full Scale(One Probe type) ±.015"/±500µm .0005"/10µm • Analog output Voltage: ±1VDC/Fullscale
519-404A Differential type ±.005"/±150µm .0001"/5µm (Accuracy: ±0.1% to ±0.3% depending on the probe.)(Two Probe type) ±.0015"/±50µm .00005"/1µm • Power: AC Adapter (Part No. 965565A)
±.0005"/±15µm .00001"/0.5µm • Optional Accessory±.00015"/±5µm .000005"/0.1µm • Digimatic code Output Interface: No. 965691
• RS-232C Interface: No. 965690A• Dimensions: 5.3"W x 7.2D x 8.3H• Weight 4 lb.
Digital Mu-CheckersInch/MetricOrder No. Style Range Resolution Remarks
519-412A Differential type ±.08"/±2mm .00005"/0.001mm •Accuracy: ±3 digit ±1(Two Probe type) • Analog output Voltage: ±1 VDC/Full ScaleLimit type (Accuracy: ±0.1% to ±0.3%—depending on the probe.‚519-414A (Two Probe type) ±.008"/±0.2mm .000005"/0.0001mm • Data output: Digimatic Codeout Interface.
• Measuring Mode: ABS/CMP (switchable)• Power: AC Adapter (Part No. 965565A)• Optional Accessory
RS-232C Interface: No. 965838B• BCD Interface No. 965839A*Dimensions: 5.3"W x 7.2"D x 8.3"H*Weight: 3.74 lb.
MU-CHECKERS
R-22
R- 022 (2003) full size 12/9/03 12:37 PM Page 1
DP-1HS
*: ■■ is left blank or an appropriate suffix (A or E) is inserted, depending onthe AC supply voltage (blank - 100V; A - 120V; E - 240V).
Sample application 1
Sample application 1: Use it as an external power supply whenconnecting to other equipment (such as MUX-10 or DP-1HS)instead of the display unit.
Sample application 2: Use it for setting the absolute origin whenconnecting an absolute-type LGD or LGD-M to a display unit otherthan the ES and EV counters.
Sample application 2
Power-supply unit for models LGD, LGD-M and LGS. Outerdimensions (W x D x H): 2.44" x 1.57" x .79" (62 x 40 x 20 mm)
Digimatic external power unit: 965275 ■■*
Special Accessories for Gage Head
Display unit
LINEAR GAGES
R-23
R- 023 (2003) full size 12/9/03 12:38 PM Page 1
Digital Mini-CheckerSeries 519
SpecificationsDigital Mini-checker
Order No. 519-621AAccuracy: ±0.3% of full scaleStability: ±1 countRepeatability: ±1 countZero Adjust Range(For Calibration): ±8% of full scaleResolution: .0001"/0.001mm, .00005"/0.0005mm,
.00002"/0.0002mm, .00001"/0.0001mm,
.000005"/0.0001mmPreset: ±9.90000"Operating Temp.: 0 to 40°C (32° to 104°F)Optimum OperatingTemp.: 18 to 25°C (64° to 77°F)Dimensions: 6.25"(W) x 6.20"(D) x 7.40"(H)Weight: 3.0 lbs.Output: Digimatic Code Out and Analog DC VoltageStandard Accessory 016823 AC/DC Power Adapter
Mitutoyo's new Digital Mini-Checker is an all-in-one, high resolution measuringunit which provides multiple inspection functions as well as digital and analogoutput. This unit allows a choice of resolutions down to 5 millionths of an inchand can use various different gage heads of the 519 Series.The Digital Mini-Checker is capable of presetting to any desired data point sothat it enables the absolute dimension or tolerance reading. It also includesGO/NG judgement and MIN/MAX hold features. It outputs digimatic codeoutand analog DC voltage.
Functions• Preset/Zero function• Go/No Go function• High/Low limit setting function• Min/Max hold function• Inch/mm function• Digimatic Code output*• Analog DC Voltage output• Zero function• Range/Resolution select function.• Large, easy to read analog display.• Correctly supports up to 5 digits
after decimal point.• Probe linearity is set using masters
or optional gage blocks.
519-621A
MU-CHECKERS
R-24
R- 024 (2003) full size 12/9/03 12:39 PM Page 1
Precautions for installation • Fasten the stem section onto the gage mount on the
measuring instrument or secure it with a stand, etc.
• Be careful not to overly tighten the stem. Doing so may cause problems in gage operation.
• Never fasten the gage by placing the tip of a screw directly against the stem.
• Never fasten the gage by any section other than its stem.
• Mount the gage in such a way that it is perpendicular to the surface to be measured. If installed at an angle, measurement errors may occur.
• Be careful not to exert force on the gage via the cables.
Straight stem and stem with nutThe stem is a part that supports the gage. There are twotypes of stems: the straight type and the one with a nut.The stem with nut can be mounted easily and ensuresthat the gage is fastened securely. The straight stemrequires extra machining for split-clamping, etc. However,this type can be used in a range of applications andoffers the advantage of allowing forward and backwardadjustment to a certain degree. Be careful not to overlytighten the straight stem.
Example 1
Examples of the straight-stem mount• The recommended clamping torque is 0.4 to 0.5Nm
(LGB-0105L: 0.2 to 0.3Nm). Overly tightening the stem will prevent smooth movement of the spindle. Check the movement of spindle after clamping.
Stem with nut Straight stem
Operational Guide and Technical DataInstalling the Gage
Example 2
LINEAR GAGES
R-25
R- 025 (2003) full size 12/9/03 12:39 PM Page 1
Set No. 02ADB680 02ADB690 02ADC730 02ADC740Applicable gage LGF 10mm LGF 25/50mm LGE/LGD 10mm LGE/LGD 25/50mmApplicable gage Code No. 542-121, 542-131 542-122, 542-132 542-601, 542-604 542-602, 542-603
542-123, 542-133 575-321, 575-331 575-322, 575-332575-324, 575-334 575-323, 575-333
Part No. Thrust stem 02ADB681 02ADB691 242327 242328Clamping Nut 02ADB682 02ADB692 200365 242330Wrench 02ADB683* 02ADB693* 200168* –
Gage mounting hole diameter Ø.37" (9.5mm) Ø.71" (18mm) Ø.37" (9.5mm) Ø.71" (18mm)Recommended plate .24~.41 .39~.47 .22~.45 .39~.47thickness (mounting section) (6~10.5mm) (10~12mm) (5.5~11.5mm) (10~12.5mm)
LGF LGE/LGD
Operational Guide and Technical DataInstalling the Gage
*: Not included in the set. It is an optional accessory.
Specifications relating to use of the thrust stem
Dimensions when using a thrust stem
LINEAR GAGES
R-26
R- 026 (2003) full size 12/9/03 12:40 PM Page 1
KH ES EF EV SDcounter counter counter counter counter
Representative Code No. 542-051 542-053 542-057 542-060A 542-062A 542-063 542-064 572-011A 572-021A 572-052AApplicable gages
0.00001mm Laser Hologage O0.0001mm Laser Hologage O O0.0001mm LGB O O0.0005mm LGF O O O0.001mm LGF O O O O O0.001mm LGB O O O O O0.001/100mm Linear Gage O O O O O0.005mm LGE O O O O O0.01mm LGD/LGD-M O O O O O0.01mm LGS O O O O O
FunctionsNumber of connectable gages 1 1 1 1 1 2 6 6 1 1 6Display O O O O O O ∆1 ∆1 O O ∆3Zero set O O O O O O ∆1 ∆1 O O OPresetting O O O O O O ∆1 ∆1 ODirection switch O O O O O O O O OGO/±NG indication O O O ∆1 ∆1 O OGO/±NG output O O O O O O O5-stage tolerance display O O5-stage tolerance output O O OSegment output O OInch/mm switch O O O O O O O O ∆4 OABS gage zero set* O OABS/INC gage changeover O OPeak hold O O O ORun out (TIR) measurement O O O ODouble count O O O ∆5Calculation function using constant OSum/difference calculation OExternal zero set ∆2 ∆2 ∆2 O O O O OExternal preset O O O O O O O ∆3External hold O O O O O O OExternal tolerance set O O O O ∆3External output off O OExternal peak-hold cancel O* O* O OTwo coordinate systems switch OInter-axial calculation function O O
OutputI/O output BCD output O O O O
Limit output O O O O ORS-232 output O O O O ODigimatic output O O O O ORS link O O O O
(Maximum number of gages) (6) (12) (60) (60)Power-supply voltage error O O O O O O OOverspeed error O O O OOverflow error O O O O O O O O O OGage error O O O O O O O O OSystem error O O OTolerance setting error O O O O O O OCommunication error O O O O
Linear Gage and Counter Connectionsand Comparisons of Counter Functions
*: The applicable gage type is LGD and LGD-M.∆1: When an optional D-EV is connected.∆2: Enabled by setting ”O“ via external presetting.
∆3: When an SD-D2 is connected.∆4: Only for models that measure in inches.∆5: Uses the calculation function using a constant.
LINEAR GAGES
R-27
R- 027 (2003) full size 12/9/03 12:40 PM Page 1
EB CounterDisplay Unit with Multiple Limits
Setting Functions for Linear Gage System
Order No. 542-092 542-094 542-093Model EB-11P EB-11Z EB-11DApplicable input Differential square-wave Differential square-wave Digimatic code (SPC)Applicable gage LGB, LGE, LGF*, 100mm LG LGF with scale reference point LGD, LGSNumber of gage input 1 1 1Resolution (count display range) .0005" (±99.9995") 0.01mm (±999.99mm)
.00005" (±99.99995") 0.005mm (±999.995mm) —.00005" (±9.99995") 0.001mm (±999.999mm)
.000005" (±.999995") 0.0005mm (±99.9995mm) —Selection with the parameter Auto-selection with gage connected
Display 6-digit and a negative (-) sign LED (green), Tolerance judgment indication LED (orange, green, red)Function Presetting, 3-/5-step x 7-bank or 7-channel x 2-bank limit setting, GO/±NG judgement,
GO/±NG signal output, MAX/MIN/TIR (runout) measurement, Counting direction switching, Scale reference point, mm/inch switching, Count standby display, Key protect
Output Tolerance judgment, Serial BCD output, Simplified analog output, Digimatic outputExternal control Preset, Data hold, Bank switching, Peak mode switching, Analog range selectionError display/output Power-supply voltage error, overspeed error, overflow error, gage error,
communication error, tolerance setting errorMax. input frequency/count speed** 1.25MHz (2-phase square waveform)/5MHz —Power supply/Power consumption Via AC adapter (12V to 24V DC, 500mA (max.))/6VAOperating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass .88 lbs. (400g)Standard accessory Six washers for adjusting the mounting plate thickness
* For LGF w/ scale reference point use 542-094
** Depending on the gage connected. The input frequency of the scale reference point signal (EB-11Z) is also restricted by the gage connected
Features• 3-/5-step x 7-bank tolerance
judgement or 7-channel x 2-bank limit setting.
• Standard serial BCD signal output for simple wiring with a PC, programmable controller, etc..
• Simple analog signal output for a dynamic measurement.
• DIN compatible 3.86" x 1.89" (96 x 48mm) and Panel-mounting compact body design.
• Choice of three models for various gage inputs.
Specifications
Dimensions
LINEAR GAGES
R-28
Order No. Description02ADB440 Output connector plug (with cover)02ADD930 Terminal block connection cable527428■■■■■■* AC Adapter02ADF180 10-Key Unit
*: ■■■■■■ is determined by the power-supply voltage specified.Used in combination with 02ADD930.
Optional Accessories
R- 028 (2003) full size 12/9/03 12:41 PM Page 1
Order No. 542-051 542-053 542-055 542-057Applicable input Differential square-wave Digimatic code (SPC)Applicable gage LGB (excluding 0.0001mm resolution), LGD, LGD-M, LGS
LGF(0.001mm reading only), LGE, 100mm LGNo. of gage input 1Resolution .00005”, .0005”, 0.001mm, 0.005mm, 0.01mm .0005”, .00005”*, 0.01mm, 0.001mm*
(Automatically set depending on the gage.)Display 6-digit and a negative [-] sign LED (red) Function • Preset • Limit setting • Preset • BCD data output • Preset • Limit setting • Preset • BCD data output
• GO/±NG judgment • inch/mm switch • GO/±NG judgment • inch/mm switch• inch/mm switch • +/- direction switch • inch/mm switch • +/- direction switch
• +/- direction switch • +/- direction switchOutput • Limit signal (3 or 5-step) • Measurement data • Limit signal (3 or 5-step) • Measurement data(open-collector) • Normal signal • Normal signal • Normal signal • Normal signal External control • Preset • Preset • Preset • Preset signal input • Data hold • Data hold • Data hold • Data hold
• Data output prohibit • Data output prohibitError display/output Power-supply voltage error, overflow error, gage error, system error,
overspeed error (542-051 and 542-055 only), tolerance setting error (542-051 and 542-055 only).Maximum input frequency 750kHz (two-phase square wave) —Power supply Terminal block (M3 screws); 12 to 24V DC, 500mA (max.) (Through an external power supply)Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass 400gStandard accessories Six washers for adjusting the mounting plate thickness
*: Will not be indicated when combined with an LG gage.
*: ■■■■■■ is determined by the power-supply voltage specified.Used in combination with 02ADD930.
ES CounterAssembly Type Display Unit
Order No. Description02ADB440 Output connector plug (with cover)02ADD930 Terminal block connection cable527428■■■■■■* AC Adapter
Optional Accessories
Features• DIN compatible compact panel-mounting 3.78" x 1.89"
(96 x 48mm). It can be easily incorporated into each system instrument.
• Two choices of data output: the BCD data output type (542-053) and the tolerance judgment output type (542-051) are available.
Dimensions
Specifications
-V+V
000001EV-I02ADD400
MADE IN JAPAN
Serial N
o.ModelCode No.
200mADC12-24V
OUT
INRS LINK
Panel thickness: .04-.13" (1-3.2mm)
Unit: inch (mm)
Code No. ***-***Model ES-11 DLSerial 000001
MADE IN JAPAN
INPUT
+V
DC IN 12-24V 500mA
-V OUTPUT
P. UNIT
Fn P.SET
ES-D
3.78" (96)
3.60" (91.4)1.75" (44.4)
+0.80
+0.80
5.39
" (1
37)
Approx..39" (10)
Dimensions of opening (panel mounting)
GO/±NG judgment indicator (542-051 only)
1.89"(48)
1.77"(45)
3.62" (92)
.26" (6.6)
LINEAR GAGES
R-29
R- 029 (2003) full size 12/9/03 12:41 PM Page 1
Order No. Description
02ADB440 Output connector plug (with cover)
02ADD950 SPC data output/RS link cable (0.5m)
936937 SPC data output/RS link cable (1m)
965014 SPC data output/RS link cable (2m)
Features• DIN compatible Panel-mounting type and DIN size
(144 x 72mm). It can be easily incorporated into eachsystem instrument.
• This counter can be used on a desktop by mounting iton the supplied stand leg.
• The standard RS-232C interface allows easy communication with an external PC.
• The RS Link function permits multiple EF counters (6 units maximum) to be connected with daisy chainand data to be input/output from one channel of the terminal RS-232C interface.
• The maximum value, minimum value, and TIR (runout)measurements are possible.
• The 2-gage input type can perform 2-axis display and makeaddition or subtraction calculations between 2 gages.
Order No. (Order number suffix denotes the AC adapter type equipped.)120V 542-065A 542-066A 542-060A 542-062AApplicable input Differential square-waveApplicable gage LGF with reference mark LGB (including 0.0001mm resolution),LGF, LGE,
100mm LG, LGH with 0.0001mm resolution1
Number of gage input 1 2 1 2(Single-display) (Double-display) (Single-display) (Double-display)
Resolution (Depending on the linear .000005”, .00005”, .0005”, .000005”, .00005”, .0005”, gage type connected) 0.0005mm, 0.001mm, 0.005mm, 0.01mm 0.0001mm, 0.0005mm, 0.001mm, 0.005mm,0.01mmDisplay 8-digit and a negative [-] sign LED (green) Function Zeroset, preset, limit setting (3 or 5-step), GO/±NG judgment, GO/±NG signal output,
MAX/MIN/TIR (runout) measurement, counting direction switching, double reading, inch/mm switching, sum/difference calculation of 2 gages (542-061, 542-062 only), output mode selection
Output I/O: Tolerance judgment output (3/5 stages), normal operation outputRS-232C or Digimatic code (selectable): Various measurement data
External Control I/O: Preset, Data hold and Error clearRS-232C: Displayed value output,MAX/MIN/TIR switching,Zero set,peak value clear,
preset value input, tolerance value input and error clearRS Link Up to six EF counters may be connected via one RS-232C port.(daisy chain)Error display/output Power-supply voltage error, overspeed error, overflow error, gage error,
communication error, and tolerance setting errorMaximum input frequency 1.25MHz (differential square-wave): Max counting Speed : 5MHzPower supply Via AC adapter (12 - 24V DC, 700mA (max))Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)Mass (main unit only) 800g 840g 760g 800gStandard accessories Stand leg (one piece), rubber feet (four pieces), washer for adjusting the mounting plate thickness
when securing the plate (six pieces), DC plug (one piece), AC adapter (excluding model 542-06X-1)1: Only one LGH may be connected to one AC adapter
(provided as a standard accessory). To connect two gages, use a 542-062-1 and a separate power supply (12 to 24V DC, 1A or greater).
EF CounterMulti-function Type
Optional Accessories
Dimensions
Dimensions of opening (panel mounting)Panel thickness:
.04 to .13" (1 to 3.2mm)
Unit: inch (mm)
Rubber foot (provided)
5.43" (138)
Showing the AC adapter connection
10¡
+1+0.5
+0.7+0.3
Stand (provided)
5.67" (144)
2.83"(72)
.12"(3.1)
6.17" (156.7)5.83" (148.2)5.39" (137)
5.39" (137).44"
(11.2)1.06" (27)
.20" (5.1)
2.68"(68)
5.43" (138)
2.68"(68)
Specifications
LINEAR GAGES
R-30
R- 030 (2003) full size 12/9/03 12:42 PM Page 1
Order No. Description02ADB440 Output connector plug (with cover)02ADD400 D-EV Display Unit02ADD950 SPC data output/RS link cable (0.5m)936937 SPC data output/RS link cable (1m)965014 SPC data output/RS link cable (2m)02ADD930 Terminal block connection cable527428■■■■■■* AC Adapter
*: ■■■■■■ is determined according to the specified power-supply voltage.Used in combination with 02ADD930.
For the gage with Digimatic Code output
For the gage with differential-square-wave output
Features• Up to six gages can be connected to one unit.
• Able to connect up to 10 EV counters to one personalcomputer using the RS link function to facilitate the configuration of a multi-point measurement system comprising a maximum of 60 gages.
• A range of output modes to choose from; I/O output for tolerance judgment and segment output, BCD dataoutput and RS-232 output are available.
• Peak-hold measurements are possible for maximumvalue, minimum value, runout (TIR), etc.
• Able to calculate a sum, average, maximum, minimum,maximum difference, etc., between gages connected to the same unit.
Interconnecting EV counters
Affixing an EV counter
Order No. 542-063 542-064 542-067Applicable input Differential square-wave Digimatic Code (SPC) Differential square-waveApplicable gage LGB (excluding 0.0001mm resolution), LGD, LGS LGF with reference mark
LGF, LGE, 100mm LGNumber of gage input 6Resolution (internal) .000005”, .00005”, .0005”, .00005”*, .0005”, .000005”, .00005”, .0005”,no display capability 0.0005mm, 0.001mm, 0.001mm*, 0.01mm 0.0005mm, 0.001mm,
0.005mm, 0.01mm 0.005mm, 0.01mmFunction GO/±NG judgment, GO/±NG signal output, MAX/MIN/TIR (runout) measurement, counting direction switching,
inch/mm switching, calculation of sum, average, maximum, minimum and maximum difference between specified axes, and output-mode selection
Output I/O: Normal operation output and GO/±NG signal (three steps), measurement data (BCD code), or 21-stage segment output (selectable) RS-232C: Various measurement data
External Control I/O: Axis designation, preset, data hold, and error clear RS-232: Displayed value output command, MAX/MIN/TIR switching and peak value clear, zero set, preset value input,
tolerance value input, error clear, and command to output calculated value between specified axesRS Link Up to 10 EV counters may be connected via a single RS-232 port. (daisy chain)
EV and EF counters can be mixed (in which case a total of six counters can be connected).Error display/output Power-supply voltage error, overspeed error, overflow error, gage error, communication error, and tolerance setting error Maximum input frequency 1.25MHz (differential square-wave): — 1.25MHz (differential square-wave):
Max counting Speed : 5 MHz Max counting Speed : 5 MHzPower supply Terminal block (M3 screws), DC +12 to +24V, 700mA (max.)Operating temperature 0°C to 40°C (20%RH to 80%RH, without condensation)Mass (main unit only) 910g 830g 910gStandard accessories Mounting feet (four pieces), brackets (four pieces), and mounting screws M4 x 8 (eight pieces)
EV Counterfor Multi-gage System Multi-function Counter
Optional Accessories
5.67" (144)
5.35" (136) 6.34" (161)
5.47" (139)
2.52
" (6
4)
.16" (4)
.16"(4)
.16" (4)
.16"(4)
.24"(6)
2.83
" (7
2)
.18" (4.5)
.26"(6.5)
.20"(5)
.20"(5)
.63"(16)
.63"(16)
Code No.***-*** Model EV-16PCode No.***-***
MADE IN JAPAN
RS LINKErr.OUTIN
LOAD 8 7 MODE 65 4
3 SEL. 2 1 DATA
F E DINPUT
C B A
RS-232CIO/BCD
+V -V
DC12-24V700mA
Unit: inch (mm)
Dimensions
Specifications
LINEAR GAGES
R-31
R- 031 (2003) full size 12/9/03 12:42 PM Page 1
02ADD930
Order No. Description02ADD930 Three-terminal section only527428 for 100V AC527428A for 120V AC527428CED for 220V AC527428CEE for 240V AC
Connected to the power supply terminalof ES/EV/D-EV counters. Use a02ADD930 together with an AC adapterfor the applicable line voltage.
Order No. Cable length02ADD950 0.5m936937 1m965014 2m
Used to interconnect EF/EV counterscomprising a RS link. Same as the cableused for Digimatic code (SPC) output.
02ADB440
This receptacle fits the I/O output plugof ES/EF/EV counters.
Number of connectable units One display unit allows external display and setting for one EV counter.
Displayed digits It uses a single sign plus six digits (EV counter operates on eight-digit data internally but displays only the last six digits).
Channel display (also for display of judgment result): 3 (three-color LED)LED display Measurement mode display (current, maximum, minimum, runout):
2 Status display: 1 (two-color)
Operating switches 4
Switches and their functions Channel switching, measurement mode switching (current value, maximum value, minimum value and runout), parameter setting, preset, and tolerance setting
Input/output RS Link connectors: 1 in and 1 out.
Error display Overspeed, gage error and others.
Power supply Terminal block (M3 screws), DC +12 to +24V, 200mA
Operating temperature (humidity) range 0°C to 40°C (20%RH to 80%RH, without condensation)
Features• Display unit for the EV counter.• Using this display allows various settings for the EV
counter without a personal computer or other equipment.• Able to display each axis measurement value and,
GO/NG judgment result, total GO/NG judgment resultfor all axes, setting details, and errors
• DIN compatible compact panel-mounting - cutoutdimensions 1.77" x 3.62" (45 x 92mm )
• The required power supply is DC +12 to +24V, 200mAat the terminal block.(AC adapter 02ADD930 and 527428■■■■■■ are available.See below.)
+0.80
+0.80
+0.31"0
+0.31"0
Options for ES/EF/EV Counters
Code No. 02ADD400Model EV-1Serial No. 000001
MADE IN JAPAN
RS LINK +V -VIN OUT
DC12-24V200mA
3.60" (91.4)
2.64" (67).26"(6.6)
1.75
" (4
4.4)
.43"(11)
MAX MINUNIT
GAGETIR
+NG
GO
-NG
P.SETMODEFnDISP
3.78" (96)
1.89
" (4
8)EV-1
Unit: inch (mm)
Dimensions
D-EV Display Unit (02ADD400)
Specifications
I/O output connector(02ADB440)
AC outputadapter
RS link cable
LINEAR GAGES
R-32
R- 032 (2003) full size 12/9/03 12:43 PM Page 1
IDS Digimatic Indicators with Absolute EncoderSeries 543
Simple and Economical Designwith Absolute EncoderFeatures • Absolute Encoder ensures all settings and readings are maintained for the
life of the battery (even when the power is turned off) • Origin (zero), inch/mm button, ±direction switch• Immune to overspeed error• SPC Output• Average battery life 20,000 hours using SR-44 battery (541980) provided
standard• quantizing error: ± 1 count
543-683B
Optional Accessories540774 Release cable903424 Lifting lever assy for ISO/JIS type903425 Lifting lever assy for AGD type02ACB420 Lug-on-center back for ISO/JIS type02ACB430 Lug-on-center back for AGD type02ACB440 Flat back02ACB610 Back with post
02ACB630 Adjustable back for ISO/JIS type02ACB620 Adjustable back for AGD type02ACB640 Back with offset lug02ACB650 Magnetic back02ACB670 Back with screw mount for ISO/JIS type02ACB660 Back with screw mount for AGD type02ACB680 Back with adjustable bracket
DIGIMATIC INDICATORS
R-33
OptionalGage Stand7004
R- 033 (2003) full size 12/9/03 12:43 PM Page 1
IDS Digimatic Indicators with Absolute EncoderSeries 543
ANSI/AGD Type (3/8" Diameter Stem and 4-48UNF Contact Point)Specifications
Order No. w/lug back 543-683 543-693 543-692 543-696Model No. ID-S1012E ID-S112T ID-S112E ID-S112PEOrder No. w/flat back 543-683B 543-693B 543-692B 543-696BModel No. ID-S1012EB ID-S112TB ID-S112EB ID-S112PEBMeasuring Range 0–.5"/0–12.7mmLCD Resolution .0005"/0.01mm .0001"/0.001mm .00005"/0.001mmAccuracy (20°C) .0008" .00012"Measuring force 0.9N or less 2.0N or less 2.0N or less 2.0N or less
Dust-resist** Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)
ISO/JIS Type (8mm Diameter Stem and M2.5 X 0.45 Contact Point)Order No. w/lug back 543-682 543-681 543-691 543-695 543-690 543-694Model No. ID-S1012M ID-S1012 ID-S112M ID-S112PM ID-S112 ID-S112POrder No. w/flat back 543-682B 543-681B 543-691B 543-695B 543-690B 543-694BModel No. ID-S1012MB ID-S1012B ID-S112MB ID-S112PMB ID-S112B ID-S112PBMeasuring Range 0–.5"/0–12.7mm 0–12.7mm 0.5"/0–12.7mm 0–12.7mmLCD Resolution .0005"/0.01mm 0.01mm .00005"/0.001mm 0.001mmAccuracy (20°C) .0008" 0.02mm .00012" 0.003mmMeasuring force 0.9N or less 0.9N or less 2.0N or less 2.0N or less 2.0N or less 2.0N or less
Dust-resist* Dust-resist** Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)Optional Connecting cables: 905338 (1m), 905409 (2m) with data send button: 959149 (1m), 959150 (2m)
DIGIMATIC INDICATORS
R-34
R- 034 (2003) full size 12/9/03 12:44 PM Page 1
IDC Type Digimatic Indicator with Absolute EncoderSeries 543
.5" Model (ANSI/AGD)
1.0" Model (ANSI/AGD)
2.0" Model (ANSI/AGD)
543-452B
543-252B
543-463B
Features• Absolute Encoder ensures all settings and readings
maintained for the life of the battery (even when poweroff).
• Preset, Zero-Set, inch/mm, +/- direction and GO/±NGfunctions.
• Face rotates 330° for use at various angles.• Immune to overspeed error.• SPC output provided• Average battery life 5,000 hours using SR-44 battery
(541980) provided standard• Quantizing error: ±1 count• Uses Mitutoyo Group 2 dial indicator mounting
backs
DIGIMATIC INDICATORS
R-35
R- 035 (2003) full size 12/9/03 12:45 PM Page 1
ANSI/AGD Type (3/8" Diameter Stem and 4-48UNF Contact Point)
Order No. w/lug back 543-272 543-279 543-276Model No. ID-C1012E ID-C1012PE ID-C1012CEOrder No. w/flat back 543-272B 543-279B 543-276B 543-456B 543-466BModel No. ID-C1012EB ID-C1012PEB ID-C1012CEB ID-C1025EB ID-C1050EBMeasuring Range 0–.5"/0–12.7mm 0–1"/0–25mm 0–2"/0–50mmLCD Resolution .0005"/0.01mmAccuracy (20°C) .0008" .0012" .0016"Measuring force 0.9N or less 2.0N or less .2, .3, .4, .5** 1.8N or less 2.3N or less
Dust-resist* Low F type*** Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)** Selectable through a combination of included spring and weight
Order No. w/lug back 543-252 543-259 543-256Model No. ID-C112E ID-C112PE ID-C112CEOrder No. w/flat back 543-252B 543-259B 543-256B 543-452B 543-462BModel No. ID-C112EB ID-C112PEB ID-C112CEB ID-C125EB ID-C150EBMeasuring Range 0–.5"/0–12.7mm 0–1"/0–25mm 0–2"/0–50mmLCD Resolution .00005"/0.001mmAccuracy (20°C) .00012" .00016"Measuring force 1.5N or less 2.0N or less .4, .6, .7N** 1.8N or less 2.3N or less
Dust-resist* Low F type*** Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)** Selectable through a combination of included spring and weight
.0001"/0.001mm Resolution
.00005"/0.001mm Resolution
.0005"/0.01mm Resolution
Order No. 543-253Model No. ID-C112T
543-253B 543-453B 543-463BID-C112TB ID-C125TB ID-C150TB
Measuring Range 0–.5"/0–12.7mm 0–1"/0–25mm 0–2"/0–50mmLCD Resolution .0001"/0.001mmAccuracy (20°C) .00012" .00016"Measuring force 1.5N or less 1.8N or less 2.3N or less
Protection Level: IP-421N=101.94gfOptional Connecting cables: 905338 (1m), 905409 (2m)Optional Connecting cables with data send button: 959149 (1m), 959150 (2m)
IDC Digimatic Indicators with Absolute EncoderSeries 543
Specifications
DIGIMATIC INDICATORS
R-36
R- 036 (2003) full size 12/9/03 12:45 PM Page 1
IDC Digimatic Indicators with Absolute EncoderSeries 543
ISO/JIS Type (8mm Diameter Stem and M2.5 X 0.45 Contact Point).0005"/0.01mm Resolution and 0.01mm ResolutionOrder No. w/lug back 543-270 543-277 543-274 543-271(Model No.) (ID-C1012) (ID-C1012P) (ID-C1012C) (ID-C1012M)Order No. w/flat back 543-270B 543-277B 543-274B 543-271B 543-454B 543-464B(Model No.) (ID-C1012B) (ID-C1012PB) (ID-C1012CB) (ID-C1012MB) (ID-C1025B) (ID-C1050B)Measuring Range 0–12mm 0–.5"/0–12.7mm 0-25mm 0-50mmLCD Resolution 0.01mm .0005"/0.01mm 0.01mmAccuracy 0.02mm 0.03mm 0.04mmMeasuring force 0.9N or less 2.0N or less .2, .3, .4, .5 N** 0.9N or less 1.8N or less 2.3N or less
Dust-resist* Low F type*** Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)**Selectable through a combination of spring and weight (both included)
Specifications
.00005"/0.001mm Resolution and 0.001mm Resolution
.5" and 12mm Model(ISO/JIS)
25mm Model (ISO/JIS) 50mm Model (ISO/JIS)
DIGIMATIC INDICATORS
R-37
Order No. w/lug back 543-250 543-257 543-254 543-251(Model No.) (ID-C112) (ID-C112P) (ID-C112C) (ID-C112M)Order No. w/flat back 543-250B 543-257B 543-254B 543-251B 543-450B 543-460B(Model No.) (ID-C112B) (ID-C112PB) (ID-C112CB) (ID-C112MB) (ID-C125B) (ID-C150B)Measuring Range 0–12mm 0–.5"/0–12.7mm 0-25mm 0-50mmLCD Resolution 0.001mm .00005"/0.001mm 0.001mmAccuracy 0.003mm 0.006mmMeasuring force 1.5N or less 2.0N or less .4, .6, .7N** 1.5N or less 1.8N or less 2.3N or less
Dust-resist* Low F type*** Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)**Selectable through a combination of spring and weight (both included)Optional Connecting cable: 905338 (1m), 905409 (2m)Optional Connecting cable with data send button: 959149 (1m), 959150 (2m)
Dimensions in mm, except where noted
R- 037 (2003) full size 12/9/03 12:46 PM Page 1
DIGIMATIC INDICATORS
R-38
IDC Type Digimatic Indicator with Absolute Encoder andPeak-Hold
Series 543
Inch/Metric–Series 543 IDC Type Digimatic Indicators with Absolute Encoder and Peak-Hold
Features• Peak hold: Displays the max. or min. value during mea-
surement.• Runout(TIR): Displays a runout(max.value-min.value)
during TIR measurement.• It is possible to set the tolerance for TIR,Max,Min value.• Absolute Encoder ensures the measurement origin is
maintained for the life of the battery.• Resistant to overspeed error.
Standard Accessories (Included)Operation manual: 99MAH004B1Batteries: SR44 (541980), 2pcs.
Optional AccessoriesOrder No.540774 Spindle lifting cable903424 Lifting lever for 543-261 and 543-260903425 Lifting lever for 543-262 and 543-263905338 SPC Connecting cable: L = 40" (1m)905409 SPC Connecting cable: L = 80" (2m)
543-262
ON/OFF in/mm
MODE
ZERO/ABS
+/-
PRESETSET
1.15"
Specifications
AB
SOLUTE
TECHNOLOGY
Order No. *1 543-262 543-263 543-261 543-260Model No. ID-C112AE ID-C112AT ID-C112AM ID-C112AResolution .00005"/0.001mm .0001"/0.001mm .00005"/0.001mm 0.001mmMeasuring range 0-.5"/0-12.7mm 0-12mmAccuracy (20°C) .00012"/0.003mm or lessQuantizing error ± 1 countStem diameter ø3/8" ø8mmContact Point 4-48UNF M2.5 x 0.45Dust/Water protection *2 Equivalent to IP-42Measuring force 1.5N (150gf) or lessPower supply Silver oxide cell (SR-44)x 2pcs. 541980Battery life Approx.1,300 hours in normal measuring. (Stop time: Measurement time = 4 : 1),
800 hrs with continuous use.Measurement frequency 50 times/s*3
Operating temperature 32~104°F (0~40°C)Storage temperature 14~140°F (-10~60°C)Net weight Approximately .35lbs/160gL.C.D. 7 segments 6digits decimal numeric with minus, sign in/mm. Tolerance judgment enlarged displayFor SPC output order connecting cable 905338 (1m) or 905409 (2m). SPC output cables with data send button: 959149 (1m), 959150 (2m)*1. For flat back model add the suffix 'B' to the code (order) number.*2. The given protection standard (IP=International Protection) is based on the IEC 529/DIN40050 part 1/JIS D0207, C0920. *3. The level indicated is valid only at a measuring speed of 50µm/s or lessAccuracy is not including quantizing error
R- 038 (2003) full size 12/9/03 12:46 PM Page 1
IDC-CG Digimatic Indicators with Absolute Encoderfor Bore Gage
Series 543
Inch/Metric–Series 543 IDC-CG Type Digimatic Indicators with Absolute Encoder for Bore Gages
Features• Capable of holding the minimum value.• Capable of tolerance judgment for the minimum value.• The analog bar shows the minimum value, upper/lower
limit values (in tolerance judgment) and the currentvalue.
• Capable of presetting 3 reference values (master val-ues), and setting a corresponding tolerance value foreach.
• A data processor can be connected.
Standard Accessories (Included)541980 Silver oxide cell SR-44, 2 pcs.99MAH005A: User's manual (English)
Thread Size 4–48 UNF
M/W
M1
M2
M3
DATA/HOLD
PRESET TOL.
START
ON/OFF
1.15" (29.3)
Ø2.
13"
(Ø54
)
2.38
" (Ø
60.5
)
2.14
" (5
4.4)
1.83
" (4
6.5)
1.95
" (4
9.6)
Ø.41"(Ø10.5)
16.5
Ø3/8"
Specifications
543-266B
AB
SOLUTE
TECHNOLOGY
Order No. 543-266B 543-267B 543-264BModel No. ID-C112GE ID-C112G ID-C112GResolution .00005"/0.001mm .0001"/0.001mm 0.001mmMeasuring range 0–.5"/0–12.7mm 0-12mmAccuracy (20°C) .00012"/0.003mm 0.003mmQuantizing error ± 1 countStem diameter ø3/8"DIA. ø8mm Contact Point 4-48UNF M2.5x0.45Protection level*1 IP-42Measuring force 1.5N (150gf) or lessBattery Silver oxide cell (SR-44), 2 pcs. 541980Battery life 9 months under normal useSampling frequency*2 50 times/s Operating temperature 0°C to 40°CStorage temperature -10°C to 60°CMass of main unit Approx. .35lbs/160gFor SPC output order connecting cable 905338 (1m) or 905409 (2m).*1. Protection level (IP=International Protection) according to IEC 529/JIS D0207. C0920.
The level indicated is valid only if the output connector cap is installed.*2. If the spindle detecting speed is over 50µm/s, the peak value may not be displayed correctly.Accuracy is not including quantizing error.
DIGIMATIC INDICATORS
R-39
R- 039 (2003) full size 12/9/03 12:47 PM Page 1
IDU Digimatic Indicator with Absolute Encoder Series 575
Inch/Metric–IDU Digimatic Indicator with Absolute Encoder575-123 575-121
Order No. (INCH/METRIC MODEL) (METRIC MODEL)Measuring range 0–1"/0–25.4mm 0–25mmLCD Resolution .0005"/0.01mm 0.01mmAccuracy .0008" 0.02mmQuantizing error ± 1 countMeasuring Force (Downward) 1.8N or less
Stem Diameter .375 0 8.0mm 0–.0012" –0.009mm
Data output Digimatic output
Standard Accessories Lifting Lever 1 pc (137693)Silver-oxide cell SR-44 1pc (541980)
Protection Level IP-42Battery Life 20,000 hrs.Note: No lug back is available for these indicators.Accuracy is not including quantizing error
Optional AccessoriesOrder No. Remarks905338 Digimatic Cable (1m)905409 Digimatic Cable (2m)540774 Spindle Lifting cable
IN MINREV
H
in/mm in/mm
ORIGIN ON/OFF
(23).91"
(38)1.50"
1.06
" (27
).5
3" (1
4.3)
(7.3
).2
5"
1.58
" (40
)(1
26)
4.96
"
8.12
"(2
07.3
)
.375 0-0.0012Ø
( 8 ) 0-0.009Ø
575-123
Unit: inch (mm)
Features• Compact and economical design.• Provided with a data output port for connection with the
SPC system.• Power supply: One SR-44 battery (541980)• Operating temperature: 0°C–40°C• Membrane sealed face helps keep out contaminants.
Functions• ON/OFF• Origin setting• Data output• Inch/mm conversion (for Inch/Metric models)• ± direction changeover• Error alarm• Low battery alarm
Specifications
AB
SOLUTE
TECHNOLOGY
DIGIMATIC INDICATORS
R-40
R- 040 (2003) full size 12/9/03 12:47 PM Page 1
IDF Digimatic Indicator with Absolute Encoder Series 543 Color Changing LCD
The IDF is Mitutoyo’s elite Digimatic Indicator with maxi-mum performance functions and the exclusive AbsoluteEncoder Technology. All the settings and readings aremaintained even if power is switched off and thesegages are immune to overspeed error.
Features• Large, backlit LCD which changes color from green to
red to indicate measurements out of set tolerance(GO/±NG).
• Analog bar display with adjustable range and toleranceindicators. Ideal for process monitoring such as zero/tol-erance zone approach.
• Preset• Max./Min. Hold mode.• TIR Function.• Zero-Set for comparison measurements.• Selectable resolutions.• ± Direction.• Function Lock (prevents unintended changes).• SPC Digimatic output.• External Power Supply.• Inch/Metric
543-558A
543-552A
Inch/Metric–Series 543 IDF Digimatic Indicators with Absolute Encoder and Color Changing LCD
Specifications
AB
SOLUTE
TECHNOLOGY
Order No. 543-551A 543-557A 543-552A 543-558AMeasuring Range 0–25mm 0–50mm 0–1.0"/0–25mm 0–2.0"/0–50.8mmLCD Resolution 0.001mm or 0.01mm .00005"/.0005"/.0001"/.001"/0.001mm/0.01mmAccuracy (20°C) 0.003mm .00012"/0.003mmQuantizing Error ± 1 count Measuring Force 1.8N or less 2.3N or less 1.8N or less 2.3N or lessStem (Dia.) 8mm 3/8" (.375")Contact Point 3mm (Dia.) Carbide Ball (M2.5x0.45mm) 901312 .16" (Dia.) Steel Ball (4-48UNF) 900032Power Supply AC Adapter (9V DC, 500mA) No.526688AData output SPC Digimatic output
Functions ZERO/ABS, PRESET, MAX./MIN. HOLD, TIR, Selectable Resolution, Digital/Analog Display,Key Lock, +/- Direction, GO/NG Judgment
Weight .53 lbs. .73 lbs. .53 lbs. .73 lbs.Optional Accessories: SPC Cable No.936937 (1m), No.965014 (2m)
Lug-on-center Back No.101040 (Metric Model)Lug-on-center Back No.101306 (Inch Model)
Accuracy is not including quantizing error
DIGIMATIC INDICATORS
R-41
R- 041 (2003) full size 12/9/03 12:48 PM Page 1
IDF Digimatic Indicator with Absolute Encoder Series 543 Color Changing LCD
1.0" and 25mm MODEL 2.0" and 50mm MODEL
1.70.43
3/8" (DIA)
2.60
.77
2.22
3.30 2.
67.6
81.
66
1.02
3.30
∆ DATA OUT DC N
in/mm +/-
ZERO/ABS
PRESET
SET ADJ
RANGE
RES. ON OFF
MODE
(8mm DIA)Metric Model
∆ DATA OUT DC N
in/mm +/-
ZERO/ABS
PRESET
SET ADJ
RANGE
RES. ON OFF
MODE
2.05
2.62
.68
3.744.
323.
35
3.28
.77
2.60.43
1.70
3/8" (DIA)
(8mm DIA)Metric Model
Unit: Inch
INC REV
Min MaxTIRH P
inmm
1
23
4
5
6
7
8
91516
10
11
12
13
14
1
Analog rangeUpper over rangeUpper pointer(blink)PointerLower pointer(blink)Lower over rangeHold sign
Function lockRelative measureReverse dir. measureMin. peak modeTIR modeMax. peak hold modeUnit
Preset the originGO/NG judgment display
56 4 3 2
15
16
8
10
7
9
11 1312 14
. .
Dimensions Dimensions
DIGIMATIC INDICATORS
R-42
R- 042 (2003) full size 12/9/03 12:48 PM Page 1
Specificationsi-Checker main unit
Dial Gage Tester i-checkerSeries 170Full/Semi-Automatic Inspection systemimproved efficiency and remarkableease of operation reduce measuringtime and virtually eliminate fatigue.
FeaturesAbsolute precision for every inspection.• Mitutoyo brings you ±(0.2+L/100)µm*1 indication
accuracy – the world's highest – for higher inspection reliability with various types of indicators and probes.
*1 When inspecting in vertical position.
Accommodating various types of indicators and probes.• Now you can directly inspect an indicator with a stroke of
up to 100mm. What's more, optional accessories let youinspect the dial test indicator, bore gage and lever-typeinductive head each with a different form of support.
Item ContentsCode No. 170-303AMeasuring range 4"/100mmResolution 1.24µin/0.02µmAccuracy vertical position ±(0.2+L/100)µm L=Arbitrary length(at 20°C) lateral position ±(0.3+2L/100)µm L=Arbitrary lengthFeed speed 4mm/sec (max)Drive method Motor driveMeasuring Unit Reflective-type metal linear encoderThermal expansion coefficient (8±1)X10-6/Kof measurement modeMeasurement method Semiautomatic measurement
Fully automatic measurement*1
Digimatic Indicator with RS-232 output*2
Input data connector Digimatic data input connector X1*3
Flat cable connector 10pin/equivalent toXG4-130 from OMRON*4
Dimensions (WxDxH) 7.24"x8.86"x20.94"/184x225x532mmOperating temperature range 20°C ±3°COperating humidity range 58%RH±15%RH (Only free of
condensation)Storage temperature range -10°C to 50°CStorage humidity range 5%RH to 90%RH (Only free of
condensation)Power supply 100VAC to 240VAC ±10%, 50/60HzMass 44lbs/20kg*1 Automatic measurement requires the indicator's connection cable. Additionally someform of indicator, along with a connecting machine (the optional accessory for indicator asa digimatic power-supply unit on EF counter) will be needed.*2 The indicator that can be measured via RS-232 is the one equipped with the function toreceive the "send data" request command form from the main unit and can output thecounter value to the main unit.*3 For the RS-232 connector, uses the connector from a computer*4 The connection cable connector is equivalent to MIL-DTL-83503/7D-10.
Applicable computer and printer *1
Item Operating environment Suggested environment(minimal condition)
Machine type IBM-PC compatibleOS Windows 2000 or NT4.0 (SPC or newer + IE 5.0 or newer)Microprocessor Pentium III 450MHZ Pentium III 600MHZ or moreMemory 64MB 128MB or moreHDD more than 50MB more than 1GB
free space except for OS free space except for OSDrive CD-ROM, FDDInterface Parallel (for printer) X1
RS-232C (for full-automatic measurement) X1Slot PCI (PC12.1 Compatible) X1: for control boardScreen resolution 1024 (W) x 768 (H) 1024 (W) x 768 (H)
x High Color (16Bit) x True Color (32Bit)*1 Windows supporting printer
Prepared Suggested Environment type Code No. Description64AAA355 Dell System w/17" Monitor
included printer HP-950C deskjet64AAA356 Dell System w/15" Flat Monitor
included printer HP-950C deskjet
Personal computer (optional)
DIAL GAGE TESTER
R-43
R- 043 (2003) full size 12/9/03 12:49 PM Page 1
SpecificationsOperation Box
Dial Gage Tester i-checkerSeries 170
Item ContentsSwitch Jog-dial Shuttle moves main unit spindle up and down.
(DATA) button Use for acquiring the measurement data.(RETRY) button Handy for retrying "measurement positioning".
Automatically removing indicator hysteresis(CANCEL) button Deletes previous data and measures it again.(STOP) switch Forcibly halts operation.
Dimension (W x D x H) 6.69" x 3.94" x 22.17"/170 x 100 x 55mmMass 2.2lbs./1kg
Special Accessories
Code No. Description1. Attachment02ASK000 Test Indicator Accessories Set (Dia. 6 Stem)02ASK180 Test Indicator Accessories Set (Dia. 8 Stem)02ASK370 Test Indicator Holder (Dia. 6 Stem)02ASK380 Test Indicator Holder (Dia. 8 Stem)02ASK110 Cylinder Gage Accessories Set902803 Dia. 6 Stem with groove902804 Dia. 8 Stem with groove2. Stem Bush02ASK040 Stem Bush Dia. 602ASJ856 Stem Bush Dia. 802ASK150 Stem Bush Dia. 8 (Short Size)02ASK050 Bush ø9.5 (Requires 02ASK070)02ASK060 Stem Bush Dia. 12
Code No. Description02ASK070 Stem Bush Dia. 1502ASK080 Stem Bush Dia. 2002ASK090 Stem Bush 3/8E02ASK130 Case for Stem Bush3. Others937179T Foot Switch02ASK730 Reflective Mirror4. Connecting Cable905338 SPC Cable (1m) *1 (ID-C, ID-S, ID-U, IDU)905409 SPC Cable (2m) *1 (ID-C, ID-S, ID-U, IDU)936937 SPC Cable (1m) *1 (ID-F, IDF)965014 SPC Cable (2m) *1 (ID-F, IDF)937387 SPC Cable (1m) *1 (ID-C, IDA)965013 SPC Cable (2m) *1 (ID-C, IDA)*1 Use the cable of specification described in the manual to the digimatic indicator and counter.
Attached bore gage acces-sory set (optional)
(RETRY) button (STOP) button
(DATA) button
Jog-dial
Attached test indicatoraccessory set (optional)
(CANCEL) buttoni-Pak (Software)Item Contents
Supporting industrial standard*1 ISO, JIS, JMAS, DIN, VDI/VDE/DGO, ANSI/ASMEBasic functions • Create an inspection standard conforming to the industrial standards.
• Create an original inspection standard, through customization industrial standard• Inspect an indicator using a newly created inspection standard (inspection for accuracy, dispersion)• Create and print of simplified inspection certificates.• Display measurement results graphically.
Other functions Warning This window is displayed when the measured value exceeds the limit during the semiautomatic inspectionRe-measurement It is possible to confirm the measuring data, by re-measuring the specified position after the inspectionDisplay of inspection manual Display the inspection manual when starting an inspection*2
Retry Use for retry the "measurement positioning". (it removes the hysteresis of indicator automatically)Password Restricted access through password registration
*1 refer to the reference materials (attached paper) for details about support for the industrial standards.*2 To create an inspection manual, it is necessary to install the application software used to create the document, in the computer where i-pak is installed
DIAL GAGE TESTER
R-44
R- 044 (2003) full size 12/9/03 12:50 PM Page 1
Calibration TestersSeries 521The Calibration Tester is specially designed to calibratecontinuous indicating accuracy of short range dial indi-cators, test indicators, and other electronic comparisongage heads. As the diagram shown on this page indi-cates, the Calibration Tester employs a horizontal beamwhich is pivoted at a 1 to 10 length ratio. Thus, a singleturn of the micrometer head creates one tenth of theactual dimension at the anvil end. In this case, one com-plete rotation of the head makes the beam move .025".However, at the anvil top, this dimension will be convert-ed to .0025".The Calibration Tester can be used with various types of measuring instruments. Some of the most commonapplications include: Mu-Checker Cartridge Heads,Lever Heads, Dial & Digimatic Indicators as well as TestIndicators.
Dial Gage TestersSeries 170It consists of a specially designed 1" micrometer, with alarge disc, and rigid holding fixtures. With graduations in.0001" on the micrometer, the Dial Gage Tester is highlyrecommended to calibrate .250", .500, .750" and 1"range, thousandths-reading, dial indicators.With the optional stand No. 951498, inspection of DialBore Gages will become much easier to perform.
521-106
SpecificationsCalibration Tester
InchMeasuring Indicating
Order No. Range Graduation Accuracy Mass Dimensions (W x D x H)521-104 0–.05" .00001" ±.00001" 15.4 lbs. 11.6" x 4" x 8.1"521-106 0–.2" .00001" ±.00003" 16.5 lbs. 11.6" x 4" x 10.9"
MetricMeasuring Indicating
Order No. Range Graduation Accuracy Mass Dimensions (W x D x H)521-103 0–1mm 0.0002mm ±0.0002mm 15.4 lbs. 11.6" x 4" x 8.1"521-105 0–5mm 0.0002mm ±0.0008mm 16.5 lbs. 11.6" x 4" x 10.9"Stem holding capacity .157" to .394" (DIA). Dual-directional graduations on micrometer head. Supplied with fitted carrying case.
SpecificationsDial Gage Tester
InchAttachment
Order No. Range Graduation Diameter Weight170-101E 0–1" .0001" 1/4", 3/8" 15.4 lbs.
MetricAttachment
Order No. Range Graduation Diameter Weight170-102M-2 0–25mm 0.001mm 6mm, 8mm 15.4 lbs.With holder bar, for Dial Bore Gages and adjustable mirror.
Optional Accessories951498 Optional stand for Dial Bore Gage inspection
170-101E
Supplied without Dial Indicator.
Shown mounted on Dial Indicator
CALIBRATION TESTERS/DIAL GAGE TESTERS
R-45
R- 045 (2003) full size 12/9/03 12:51 PM Page 1
BEZEL DIA.
MinimumPositionB
MIT
UTOY
O Se
ries
AGD
Serie
s
Mil
Spec
s.
To andAbove including
0 0 0 1" 1-3/8" 1-9/32"1 1 1 1-3/8" 2" 1-5/8"2 2 2 2" 2-3/8" 2"3 3 3 2-3/8" 3" 2-1/8"4 4 4 3" 3-3/4" 2-9/16"
Dial IndicatorsGroup 0/1/2/3/4
SpecificationsMitutoyo offers dial indicators in fourbasic AGD Groups, with inch and metricgraduations. These instruments conformto the three specifications governing dialindicators, highlights of which follow.
In addition to the AGD Groups of dialindicators, MITUTOYO offers “Hicators”which are ultra-sensitive, high-magnification indicators, reading in 50 millionths directly on the dial face.
American Gage Design (AGD)
To standardize minimum essentialrequirements for precision dial indicators, AGD Specifications wereintroduced in 1945 as a CommercialStandard.
They provide standards of performanceand basic exterior dimensions in orderto permit interchangeability. Following is a digest of the specifications.
a. Repeatability – within plus or minusone-fifth graduation at any point.
b. Accuracy – shall be accurate to within one graduation, plus or minus,at any point (2-1/3 turns).
c. Spindle Range – the range of spindletravel should be a minimum of 2-1/2revolutions of the indicating hand.
d. Hand Position – the indicating handshall be set at the approximate 9 o'clock position when the spindle is fully extended.
e. Smallest graduation – inch: .00005",.0001", .0005" and .001". Metric:0.001mm, 0.002mm, 0.005mm and0.01mm.
f. Dial Numbering – inch: dial numbersshall always indicate thousandths ofan inch regardless of magnification.Metric: dial numbers shall alwaysindicate hundredths of a millimeter.
Military Specifications (A-A-2348)
The MIL Specifications, approved by theDepartment of Defense, incorporatemost AGD specifications, and set forthtest procedures for the determination ofrepeatability, accuracy and durability.
Some of the highlights are:
a. Repeatability – within plus or minusone-fifth graduation and before andafter 500,000 deflections.
b. Accuracy – shall be accurate to within one graduation, plus or minus,at any point (2-1/3 turns).
Note: Travel of spindle equals a minimumof 2-1/2 turns if hand in all groups DA
DA means American Gage Design Specification
c. Accuracy (calibration) – a minimumof 8 points, in equal increments overthe range shall be calibrated (inwardand outward deflections withoutresetting the indicator dial).
d. Repeatability (check points) – shallbe checked for repetition of readingsat points approximately 25, 50 and75 percent of the full range.
e. Durability – the indicator shall showno signs of significant wear or failuresubsequent to 500,000 full scaledeflections.
f. Contact pressure – maximum forceto deflect spindle was set forth on all types of dial and test indicators to indicate sensitivity requirements.
ANSI Specifications (ANSI B89.1.10)
Most recent specifications now proposedby the American National StandardInstitute for mutual understandingbetween manufacturers and users. Thebasic contents confirm AGD and MILspecifications. However, it proposes thefollowing:
a. Metric dial face shall be yellow.
b. Graduations Inch: .00005", .0001",.0005" and .001". Metric: 0.001mm,0.002mm, 0.01mm and 0.02mm(0.005mm graduation recognized byAGD was eliminated).
Mitutoyo Indicators meet AllSpecifications
(with the exception of 8mm stem models).
DA
NOMINAL BEZEL DIAMETER
BEZEL CLAMP
INDICATINGHAND
.25
STEM
SPINDLE
4.48 THREAD DA
REMOVABLECONTACT POINT
DIALFACE
DA.75
CASE
MOUNTINGLUG .25 THICK DA
DA.25
MIN. DISTANCE FROMCENTER OF HOLE TONEAREST PROJECTIONON BACK
DA.31
DA.25
CRYSTAL
B (
MIN
PO
SIT
ION
)
DA.375
DA
TRAVEL
BEZEL
SELECTION GUIDE
R-46
R- 046 (2003) full size 12/9/03 12:52 PM Page 1
Mitutoyo Dial Indicator Dial Faces
055
10 10
15 15
20
_ +
0 1
2
3
.001
NO. 192150
01010
2020
3030
4040
_ +
MADE IN
.001"— 250"NO. 1411
50
01010
2020
3030
4040
_ +
MADE IN
.001"— 250"NO. 1411
50
01010
2020
3030
4040
MADE
.001"— 250"NO. 1411
50
01010
2020
3030
4040
_ +
.001"— 250"NO. 1411
Group 1
SHOCK P ROOF
NO. 2670-08 ®
.0005"
05
10
1520
25
30
35
012
3
.001"
SHOCK P ROOF
NO. 2907-08 ®
.0005"
012
3
055
1010
1515
202025
SHOCK P ROOF
NO. 2922-08 ®
.0005"
01
2 3
055
_
1010
1515
202025
+
+ _
09010
8020
7030
604050
01
2
345
67
89
010 10
20 20
30 30
40 40
SHOCK P ROOF
NO. 2904 ®
.001"
SHOCK PROOF
NO. 2608-63
_ +
Continuous
One revolution
Balanced
Reversed balanced
Reversed continuous(Counter clock-wise)
Group 2 Group 3 Group 4Group 0
Five Group SizesThe SIZE of the dial face is indicated by the Group Number.
Group 0 – Dial Face Diameter 1-7/32"Group 1 – Dial Face Diameter 1-5/8"Group 2 – Dial Face Diameter 2-1/4"Group 3 – Dial Face Diameter 3"Group 4 – Dial Face Diameter 3-9/16"
Mitutoyo Dial Indicators are available with
5 Types of Dial Faces
SELECTION GUIDE
R-47
R- 047 (2003) full size 12/9/03 12:52 PM Page 1
Order by the Numbers
The Letter Suffix:Unless otherwise specified, the DialIndicator will be supplied with a Lug-on-Center Back. Otherwise, the fol-lowing suffixes will appear immediatelyafter the model number. Please specifywhen ordering.2044B – the “B” letter means Flat Backinstead of Lug-on-Center back.2047F – the “F” letter indicates an indicator supplied with Mitutoyo’s new-type Flat Crystal which has onepiece Bezel and Crystal. For moistureresistance, metric models have agroove at the stem bottom.2046FE – the “FE” letter indicates newtype Flat Crystal (metric model only).
The Two NumberSuffix:After the hyphen (-), the two numbersthat follow it have specific meanings.Consequently, we have a First Suffix orthe features designated by the firstnumerals of this double digit figure and the Second Suffix which furtherspecifies the indicator feature.First Suffix – The First number of thetwo digit suffix.2947-10 – “1” indicates that the indicator has Jeweled Bearings.2945-40 – “4” indicates that the indica-tor is “ND-type”, an indicator with amodified integral gear assembly.2470-50 – “5” indicates an ND-type(same as above) with Jeweled Bearing.2410-60 – “6” indicates withWaterproof feature.
2910-72 – “7” indicates ND-type withboth Waterproof and Jeweled Bearings.2805F-80 – “8” indicates that the indicator is furnished with Spindle Stop feature.Second Suffix – The last number of thetwo digit suffix.2109-11 – “1” indicates that this is aMetric indicator, ANSI specification.2910-72 – “2” indicates that the indicator has Shockproof and DustProof features.2900-73 – “3” indicates a Metricindicator, ANSI specs, with Shockproofand Dust Proof features.2410F-06 – “6“ indicates black dialface with orange hands.2046-69 – “9” indicates that theindicator is furnished with Shockproofmechanism.
Group Number "Letter Suffix" "Second Suffix"
Model Number "First Suffix"
Option "B"With Flat
Back
Standard "F"Flat Crystal Dial Face with
Lug-on-Center Back
Metric ModelHas Groove at Stem Bottom
Option "FE"(Metric model only)
Flat Crystal Dial Face with Lug-on-Center Back
Option "FB"Flat Crystal Dial Face
with Flat Back
2044B-61
SELECTION GUIDE
R-48
R- 048 (2003) full size 12/9/03 12:53 PM Page 1
Selection Guide for Dial Indicators – Inch ModelsRange Total Dial
Graduation Per Rev. Range Reading Group 0 Group 1 Group 2 Group 3 Group 4.0001" .004" .01" 0-2-0 1927-10
.008" .02" 0-4-0 2937F-100-8 2938F-10
.01" .025" 0-10 1802-10 2802F-10 2802F-60 3802-10 4802-100-5-0 1925-10 1803-10 2803F-10 2803F-60 3803-10 4803-10
.05" 0-10 2804F-1010-0 2905F-100-5-0 2805F-10 2805F-80 2923F-10
.1" 0-10 2806F-10 2806F-60.25" 0-10 2356-50.5" 0-10 2358-50
.02" .05" 0-20 4818-10.00025" .01" .025" 0-10 2600F-10
0-5-0 2601F-10.02" .05" 0-20 1470 1470-10 2470-50
0-10-0 1471 2471-50.2" 0-20 1476.24" 0-20 2476F-60
.0005" .05" 0-20 2500F-100-10-0 1923 2501F-10
.03" .075" 0-30 1570-10 2570F 2570F-10 2570F-60 3570 45700-15-0 1571-10 2571F 2571F-10 2571F-60 3571 4571
.3" 0-30 2576F-60.04" .1" 0-40 1670 2670F 2670F-10
0-20-0 1671 1671-10 2671F 2671F-10.4" 0-20-0 2675F
.05" .125 0-50 1506 2506F 2506F-100-25-0 1507 1507-10 2507F 2507F-100-25-0 2922F50-0 2906F
.5" 0-50 2514F 2514F-601" 0-50 2776F 2776F-60
.001" .02" .05" 0-20 1400-10 2400F-100-10-0 1401-10 2401F-10
.03" .075" 0-30 1580-100-15-0 1581-10
.04" .1" 0-40 1404-10 2404F-100-20-0 1921 1405-10 2405F-10
.05" .125" 0-50 1780 2780F 2780F-10 37800-25-0 1781 1781-10 2781F 2781F-10 3781
.1" .25" 0-100 1410 1410-10 2410F 2410F-06 2410F-10 3410 44102410F-60 2919F-10
0-50-0 1411 2411F 2411F-10 2920F-10 3411 44110-100
.4" 0-100 2412F 2412F-60 2412F-80 34120-50-0 2413F 3413100-0 2903F
.5" 0-100 2414F 2414F-06 2414F-102414F-60 2915F-10
0-50-0 2415F 2415F-10 2415F-60 2918F-10
1" 0-100 2416F 2416F-06 34162416F-10 2416F-60
0-50-0 2417F 3417100-0 2904F
2" 0-100 2424-10 3424-103" 0-100 3426-10 48874" 0-100 3428-10
.01" 1" 1" 0-1000 2204F
SELECTION GUIDE
R-49
R- 049 (2003) full size 12/9/03 12:53 PM Page 1
Selection Guide for Dial Indicators – Metric Models
Range Total DialGraduation Per Rev. Range Reading Group 0 Group 1 Group 2 Group 3 Group 40.001mm 0.1mm 1mm 0-100 2110F 2110F-60
0.2mm 1mm 0-100-0 1109F 2109F 2109F-60 3109F0-10-0 2109F-11
2mm 0-100-0 2113F5mm 0-100-0 2119F
0-10-0 2119F-110-100-100 2118F
0.002mm 0.2mm 0.5mm 0-20 1010-11 2010F-11 2010F-61 3010-110-10-0 1011-11 2011F-11 2011F-61 3011-110-100-0 1913-10
1mm 0-100-0 1013F0.005mm 0.5mm 1.25mm 0-50 2120F-11 2120-71
0-25-0 2121F-11 2121-713.5mm 0-50 1124F
0-25-05mm 0-50 2124F
0.01mm 0.5mm 3.5mm 0-50 1040F0-25-0 1041F
1mm 2.5mm 0-100 1230-01 2230F-01 2230F-11 3230-01 4230-010-50-0 1911 1231-01 2231F-01 2231F-11 3231-01 4231-010-100-0
4mm 0-50-0 10035mm 0-100 1044-01 2044F-01 2044F-61 2044F
1044F 2044FE-09 2044F-601044F-601044F-10
0-50-0 1045F 2045F-61 2045F-01 2045FE1045-01 2045F-60
10mm 0-100 2046F-01 2046F-11 2046F-61 3046F 40462046F 2046FE 2046F-60
2046FE-09 2046F-69 2046FE-102048F-01 2048F-11 2310FE
0-50-0 2047F-01 2047F-11 2047FE 3047F100-0 2902F-01 2902FE
20mm 0-100 2050F-01 2050F-60 2050FE 3050F2050F-11 2320FE
25mm 0-100 2056F-0130mm 0-100 2052FE 3052-01
2330FE 3052-113052F
100-0 2952FE50mm 0-100 3058-01
3058-113058F
80mm 0-100 3060F100mm 0-100 3062F
0.02mm 2mm 5mm 0-200 2032F-110-100-0 2033F-11
SELECTION GUIDE
R-50
R- 050 (2003) full size 12/9/03 12:54 PM Page 1
Selection Guide for Dial Indicators
DialGraduation Range Reading Group 0 Group 1 Group 2 Group 3 Group 4
.0001" .006" 3-0-3 1910-72
.008" 4-0-4 2910-72 2947F-10
.0005" .04" 20-0-20 1909-62 2909-62
.02" 10-0-10 2976
.04" 20-0-20 2977
.001" .06" 30-0-30 2978
.08" 40-0-40 2908-62 2945-40
.01" 1" 0-1000 2204F
One Revolution Type – Inch Models
DialGraduation Range Reading Group 0 Group 1 Group 2 Group 3 Group 4
0.001mm 0.1mm 50-0-50 1900F-62 2900-73 2900F
0.16mm 80-0-80 2901F
0.01mm 0.5mm 25-0-25 2971
1mm 50-0-50 1929F 2929F 29721929F-62
0.02mm 1.6mm 80-0-80 2973
One Revolution Type – Metric Models
Range Total DialGraduation Per Rev. Range Reading Group 0 Group 1 Group 2 Group 3 Group 4
.0001" .008" 4-0-4 2991
.0005" .04" 20-0-20 2961
.001" .05" .04" 20-0-20 1961
.2" 0-50 1166
50-0 1168
0-25-0 1167
.1" .1" 0-100 1156
0-50-0 1157
Back Plunger – Inch Models
Range Total DialGraduation Per Rev. Range Reading Group 0 Group 1 Group 2 Group 3 Group 4
0.001mm 0.1mm 50-0-50 2990
0.01mm 1mm 1mm 50-0-50 1960 2960
5mm 0-100 1160
0.02mm 2.6mm 2.6mm 0-260 1158
0-130-0 1159
Back Plunger – Metric Models
SELECTION GUIDE
R-51
R- 051 (2003) full size 12/9/03 12:54 PM Page 1
Selection Guide for Dial Indicators
DialGraduation Range Reading Group 0 Group 1 Group 2 Group 3 Group 4
.00002" ±.001" 1-0-1 524-524
.00005" ±.002" 2-0-2 524-522
.0001" ±.004" 4-0-4 524-606*
.0005" ±.02" 20-0-20 524-607*
Hicator and Hicator-II – Inch Models
DialGraduation Range Reading Group 0 Group 1 Group 2 Group 3 Group 4
0.0005mm ±0.025mm 25-0-25 524-523
±0.03mm 30-0-30 524-500
0.001mm ±0.05mm 50-0-50 524-601*
524-501
±0.05mm 50-0-50 524-521
0.002mm ±0.1mm 100-0-100 524-602*
0.01mm ±0.5mm 50-0-50 524-603*
Hicator and Hicator-II – Metric Models
* Signal Type Hicator
* Signal Type Hicator
SELECTION GUIDE
R-52
R- 052 (2003) full size 12/9/03 12:55 PM Page 1
R-53
SELECTION GUIDE
Numerical Index for Dial IndicatorsOrder Range Total DialNumber Grad. per Rev. Range Reading
Order Range Total DialNumber Grad. per Rev. Range Reading
1003 0.01mm 1mm 4mm 0-50-01010-11 0.002mm 0.2mm 0.5mm 0-201011-11 0.002mm 0.2mm 0.5mm 0-10-01013F 0.002mm 0.2mm 1mm 0-100-01040F 0.01mm 0.5mm 3.5mm 0-501041F 0.01mm 0.5mm 3.5mm 0-25-01044-01 0.01mm 1mm 5mm 0-1001044F 0.01mm 1mm 5mm 0-1001044F-10 0.01mm 1mm 5mm 0-1001044F-60 0.01mm 1mm 5mm 0-1001045-01 0.01mm 1mm 5mm 0-50-01045F 0.01mm 1mm 5mm 0-50-01109F 0.001mm 0.2mm 1mm 0-100-01124F 0.005mm 0.5mm 3.5mm 0-501156 .001" .1" .1" 0-1001157 .001" .1" .1" 0-50-01158 0.02mm 2.6mm 2.6mm 0-2601159 0.02mm 2.6mm 2.6mm 0-130-101160 0.01mm 1mm 5mm 0-1001166 .001" .05" .2" 0-501167 .001" .05" .2" 0-25-01168 .001" .05" .2" 50-01230-01 0.01mm 1mm 2.5mm 0-1001231-01 0.01mm 1mm 2.5mm 0-50-01400-10 .001" .02" .05" 0-201401-10 .001" .02" .05" 0-10-01404-10 .001" .04" .1" 0-401405-10 .001" .04" .1" 0-20-01410 .001" .1" .25" 0-1001410-10 .001" .1" .25" 0-1001411 .001" .1" .25" 0-50-01470 .00025" .02" .05" 0-201470-10 .00025" .02" .05" 0-201471 .00025" .02" .05" 0-10-01476 .00025" .02" .2" 0-201506 .0005" .05" .125" 0-501507 .0005" .05" .125" 0-25-01507-10 .0005" .05" .125" 0-25-01570-10 .0005" .03" .075" 0-301571-10 .0005" .03" .075" 0-15-01580-10 .001" .03" .075" 0-301581-10 .001" .03" .075" 0-15-01670 .0005" .04" .1" 0-401671 .0005" .04" .1" 0-20-01671-10 .0005" .04" .1" 0-20-01780 .001" .05" .125" 0-501781 .001" .05" .125" 0-25-01781-10 .001" .05" .125" 0-25-01802-10 .0001" .01" .025" 0-101803-10 .0001" .01" .025" 0-5-01900F-62 0.001mm 0.1mm 50-0-501909-62 .0005" .04" 20-0-201910-72 .0001" .006" 3-0-31911 0.01mm 1mm 2.5mm 0-50-01913-10 0.002mm 0.2mm 0.5mm 0-100-01921 .001" .04" .1" 0-20-0
1923 .0005" .02" .05" 0-10-01925-10 .0001" .01" .025" 0-5-01927-10 .0001" .004" .01" 0-2-01929F 0.01mm 1mm 50-0-501929F-60 0.01mm 1mm 50-0-501929F-62 0.01mm 1mm 50-0-501960 0.01mm ± 0.5mm 50-0-501961 .001 ± .02 20-0-202010F-11 0.002mm 0.2mm 0.5mm 0-202010F-61 0.002mm 0.2mm 0.5mm 0-202011F-11 0.002mm 0.2mm 0.5mm 0-10-02011F-61 0.002mm 0.2mm 0.5mm 0-10-02032F-11 0.02mm 2mm 5mm 0-2002033F-11 0.02mm 2mm 5mm 0-100-02044F 0.01mm 1mm 5mm 0-1002044F-01 0.01mm 1mm 5mm 0-1002044F-60 0.01mm 1mm 5mm 0-1002044F-61 0.01mm 1mm 5mm 0-1002044FE-09 0.01mm 1mm 5mm 0-1002045F-01 0.01mm 1mm 5mm 0-50-02045FE 0.01mm 1mm 5mm 0-50-02045F-60 0.01mm 1mm 5mm 0-50-02045F-61 0.01mm 1mm 5mm 0-50-02046F 0.01mm 1mm 10mm 0-1002046F-01 0.01mm 1mm 10mm 0-1002046F-11 0.01mm 1mm 10mm 0-1002046F-60 0.01mm 1mm 10mm 0-1002046F-61 0.01mm 1mm 10mm 0-1002046F-69 0.01mm 1mm 10mm 0-1002046FE 0.01mm 1mm 10mm 0-1002046FE-09 0.01mm 1mm 10mm 0-1002046FE-10 0.01mm 1mm 10mm 0-1002047F-01 0.01mm 1mm 10mm 0-50-02047F-11 0.01mm 1mm 10mm 0-50-02047FE 0.01mm 1mm 10mm 0-50-02048F-01 0.01mm 1mm 10mm 0-1002048FE-10 0.01mm 1mm 10mm 0-1002048F-11 0.01mm 1mm 10mm 0-1002050F-01 0.01mm 1mm 20mm 0-1002050FE-10 0.01mm 1mm 20mm 0-1002050F-11 0.01mm 1mm 20mm 0-1002050F-60 0.01mm 1mm 20mm 0-1002050FE 0.01mm 1mm 20mm 0-1002052FE 0.01mm 1mm 30mm 0-1002052FE-10 0.01mm 1mm 30mm 0-1002056F-01 0.01mm 1mm 25mm 0-1002109F 0.001mm 0.2mm 1mm 0-100-02109F-11 0.001mm 0.2mm 1mm 0-100-02109F-60 0.001mm 0.2mm 1mm 0-100-02110F 0.001mm 0.1mm 1mm 0-1002110F-60 0.001mm 0.1mm 1mm 0-1002113F 0.001mm 0.2mm 2mm 0-100-02118F 0.001mm 0.2mm 5mm 0-100-1002119F 0.001mm 0.2mm 5mm 0-100-02119-51 0.001mm 0.2mm 5mm 0-10-02120F-11 0.005mm 0.5mm 1.25mm 0-50
R- 053 , 54, 55 (2003) full size 12/9/03 12:56 PM Page 1
R-54
SELECTION GUIDE
Numerical Index for Dial IndicatorsOrder Range Total DialNumber Grad. per Rev. Range Reading
Order Range Total DialNumber Grad. per Rev. Range Reading
2120-71 0.005mm 0.5mm 1.25mm 0-502121F-11 0.005mm 0.5mm 1.25mm 0-25-02121-71 0.005mm 0.5mm 1.25mm 0-25-02124F 0.005mm 0.5mm 5mm 0-502204F .01" 1" 1" 0-10002230F-01 0.01mm 1mm 2.5mm 0-1002230F-11 0.01mm 1mm 2.5mm 0-1002231F-01 0.01mm 1mm 2.5mm 0-50-02231F-11 0.01mm 1mm 2.5mm 0-50-02310FE 0.01mm 1mm 10mm 0-1002320FE 0.01mm 1mm 20mm 0-1002330FE 0.01mm 1mm 30mm 0-1002356-50 .0001" .01" .25" 0-102358-50 .0001" .01" .5" 0-102400F-10 .001" .02" .05" 0-202401F-10 .001" .02" .05" 0-10-02404F-10 .001" .04" .1" 0-402405F-10 .001" .04" .1" 0-20-02410F .001" .1" .25" 0-1002410F-06 .001" .1" .25" 0-1002410F-10 .001" .1" .25" 0-1002410F-60 .001" .1" .25" 0-1002411F .001" .1" .25" 0-50-02411F-10 .001" .1" .25" 0-50-02412F .001" .1" .4" 0-1002412F-60 .001" .1" .4" 0-1002412F-80 .001" .1" .4" 0-1002413F .001" .1" .4" 0-50-02414F .001" .1" .5" 0-1002414F-06 .001" .1" .5" 0-1002414F-10 .001" .1" .5" 0-1002414F-60 .001" .1" .5" 0-1002415F .001" .1" .5" 0-50-02415F-10 .001" .1" .5" 0-50-02415F-60 .001" .1" .5" 0-50-02416F .001" .1" 1" 0-1002416F-06 .001" .1" 1" 0-1002416F-10 .001" .1" 1" 0-1002416F-60 .001" .1" 1" 0-1002417F .001" .1" 1" 0-50-02424-10 .001" .1" 2" 0-1002470-50 .00025" .02" .05" 0-202471-50 .00025" .02" .05" 0-10-02476F-60 .00025" .02" .24" 0-202500F-10 .0005" .02" .05" 0-202501F-10 .0005" .02" .05" 0-10-02506F .0005" .05" .125" 0-502506F-10 .0005" .05" .125" 0-502507F .0005" .05" .125" 0-25-02507F-10 .0005" .05" .125" 0-25-02514F .0005" .05" .5" 0-502514F-60 .0005" .05" .5" 0-502570F .0005" .03" .075" 0-302570F-10 .0005" .03" .075" 0-302570F-60 .0005" .03" .075" 0-302571F .0005" .03" .075" 0-15-0
2571F-10 .0005" .03" .075" 0-15-02571F-60 .0005" .03" .075" 0-15-02576F-60 .0005" .03" .3" 0-302600F-10 .00025" .01" .025" 0-102601F-10 .00025" .01" .025" 0-5-02670F .0005" .04" .1" 0-402670F-10 .0005" .04" .1" 0-402671F .0005" .04" .1" 0-20-02671F-10 .0005" .04" .1" 0-20-02675F .0005" .04" .4" 0-20-02776F .0005" .05" 1" 0-502776F-60 .0005" .05" 1" 0-502780F .001" .05" .125" 0-502780F-10 .001" .05" .125" 0-502781F .001" .05" .125" 0-25-02781F-10 .001" .05" .125" 0-25-02802F-10 .0001" .01" .025" 0-102802F-60 .0001" .01" .025" 0-102803F-10 .0001" .01" .025" 0-5-02803F-60 .0001" .01" .025" 0-5-02804F-10 .0001" .01" .05" 0-102805F-10 .0001" .01" .05" 0-5-02805F-80 .0001" .01" .05" 0-5-02806F-10 .0001" .01" .1" 0-102806F-60 .0001" .01" .1" 0-102900-73 0.001mm 0.1mm 50-0-502900F 0.001mm 0.14mm 0.1mm 50-0-502900F-62 0.001mm 0.14mm 0.1mm 50-0-502901F 0.001mm 0.2mm 0.16mm 80-0-802902F-01 0.01mm 1mm 10mm 100-02902FE 0.01mm 1mm 10mm 100-02903F .001" .1" .4" 100-02904F .001" .1" 1" 100-02905F-10 .0001" .01" .05" 10-02906F .0005" .05" .125" 50-02908-62 .001" .08" 40-0-402909-62 .0005" .04" 20-0-202910-72 .0001" .008" 4-0-42915F-10 .001" .1" .5" 0-1002918F-10 .001" .1" .5" 0-50-02919F-10 .001" .1" .25" 0-1002920F-10 .001" .1" .25" 0-50-02922F .0005" .05" .125" 0-25-02923F-10 .0001" .01" .05" 0-5-02928F 0.01mm 0.4mm 4mm 2-0-22929F 0.01mm 1mm 50-0-502929-62 0.01mm 1mm 50-0-502937F-10 .0001" .008" .02" 0-4-02938F-10 .0001" .008" .02" 0-82945-40 .001" .08" 40-0-402947F-10 .0001" .008" 4-0-42952FE 0.01mm 1mm 30mm 100-02959F 0.01mm 1.6mm 80-0-802960 0.01mm ± 0.5mm 50-0-502961 .0005" .04" 20-0-202971 0.01mm 0.5mm 25-0-25
R- 053 , 54, 55 (2003) full size 12/9/03 12:57 PM Page 2
R-55
SELECTION GUIDE
Numerical Index for Dial IndicatorsOrder Range Total DialNumber Grad. per Rev. Range Reading
Order Range Total DialNumber Grad. per Rev. Range Reading
2972 0.01mm 1mm 50-0-502973 0.02mm 1.6mm 80-0-802976 .0005" .02" 10-0-102977 .0005" .04" 20-0-202978 .001" .06" 30-0-302990 0.001mm 0.1mm 50-0-502991 .0001" .008" 4-0-43010-11 0.002mm 0.2mm 0.5mm 0-203011-11 0.002mm 0.2mm 0.5mm 0-10-03046F 0.01mm 1mm 10mm 0-1003047F 0.01mm 1mm 10mm 0-50-03050F 0.01mm 1mm 20mm 0-1003052F 0.01mm 1mm 30mm 0-1003052-01 0.01mm 1mm 30mm 0-1003052-11 0.01mm 1mm 30mm 0-1003058-01 0.01mm 1mm 50mm 0-1003058-11 0.01mm 1mm 50mm 0-1003058F 0.01mm 1mm 50mm 0-1003060F 0.01mm 1mm 80mm 0-1003062F 0.01mm 1mm 100mm 0-1003109F 0.001m 0.2mm 1mm 0-100-03230-01 0.01mm 1mm 2.5mm 0-1003231-01 0.01mm 1mm 2.5mm 0-50-03410 .001" .1" .25" 0-1003411 .001" .1" .25" 0-50-03412 .001" .1" .4" 0-1003413 .001" .1" .4" 0-50-03416 .001" .1" 1" 0-1003417 .001" .1" 1" 0-50-03424-10 .001" .1" 2" 0-1003426-10 .001" .1" 3" 0-1003428-10 .001" .1" 4" 0-100
3570 .0005" .03" .075" 0-303571 .0005" .03" .075" 0-15-03780 .001" .05" .125" 0-503781 .001" .05" .125" 0-25-03802-10 .0001" .01" .025" 0-103803-10 .0001" .01" .025" 0-5-04046 0.01mm 1mm 10mm 0-1004230-01 0.01mm 1mm 2.5mm 0-1004231-01 0.01mm 1mm 2.5mm 0-50-04410 .001" .1" .25" 0-1004411 .001" .1" .25" 0-50-04570 .0005" .03" .075" 0-304571 .0005" .03" .075" 0-15-04802-10 .0001" .01" .025" 0-104803-10 .0001" .01" .025" 0-5-04818-10 .0001" .02" .05" 0-204887 .001" .1" 3" 0-100524-500 0.0005mm ± 0.03mm 30-0-30524-501 0.001mm ± 0.05mm 50-0-50524-502 0.002mm ± 0.1mm 100-0-100524-505 .00005" ± .002" 2-0-2524-510 .00002" ± .001" 1-0-1524-521 0.001mm ± 0.05mm 50-0-50524-522 .00005" ± .002" 2-0-2524-523 0.0005mm ± 0.025mm 25-0-25524-524 .00002" ± .001" 1-0-1524-601 0.001mm ± 0.05mm 50-0-50524-602 0.002mm ± 0.1mm 100-0-100524-603 0.01mm ± 0.5mm 50-0-50524-605 .00005" ± .002" 2-0-2524-606 .0001" ± .004" 4-0-4524-607 .0005" ± .02" 20-0-20
R- 053 , 54, 55 (2003) full size 12/9/03 12:57 PM Page 3
Dial Indicators / Group 0Inch/Metric
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
1923
Inch–ANSI Standard (Stem Diameter 3/8")Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features.0001" .01" 1927-10 .004" 0-2-0 ±.0002" ±.0002"
.025" 1925-10 .01" 0-5-0 ±.0002" ±.0002".0005" .05" 1923 .02" 0-10-0 ±.0005" ±.0005".001" .1" 1921 .04" 0-20-0 ±.001" ±.001"
The measuring force for all of the above indicators is 1.4N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat-back version add 'B' to the order number, e.g. 1927B-10.
Metric–Standard (Stem Diameter 8mm)Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features0.002mm 0.5mm 1913-10 0.2mm 0-100-0 ±0.011mm ±0.011mm0.01mm 2.5mm 1911 1mm 0-50-0 ±0.011mm ±0.011mm
Specifications
1913-10 1911
1927-10 1925-10
1923 1921
0 10102020
30304040
5050
6060
70708080
9090 100
0
12
3
J E W E L E D
MADE IN JAPAN
NO. 1913-10
2µm
_ + 01010
2020
3030
404050
0 1
2
3
MADE IN JAPAN
NO. 1911
0.01mm
_ +
J E W E L E D
MADE IN JAPAN
NO. 1927-10
0
.5.5
11
1.51.52
0
1
23
.0001"
_ +
MADE IN JAPAN
022
44
66
8810
_ +
NO. 1923
0 1
2
3
.0005"
NO. 1921
0
5 5
1010
1515
20
0 1
2
3
.001"
_ +
011
22
33
445
0
12
3
NO. 1925-10
.0001"
_ +
Dial Indicators
.49" .75" ø.26"
Thickness .25"
ø.375"
0-.001
#4-48 Threads
.28"
A
B
.59"
ø1.
22
.63"
1.18
"
DimensionsOrder Number A B
1927-10 1.46" .26"1925-10 1.48" .28"1923 1.51" .31"1921 1.58" .37"
Dimensions (mm)Order Number A B
1911 42 11.5
1913-10 39.5 9
Inch Metric
12.5 20 ø6.5
Thickness 5
ø8 0 -0.009
M2.5x0.45
7
A
B
15
ø
31
16
30
Unit: Inch Unit: mm
Dial Indicator FacesGroup 0 – Inch/Metric
DIAL INDICATORS/INCH
R-56
R- 056 (2003) full size 12/9/03 1:00 PM Page 1
Dial Indicators / Group 1Inch
1411F
Inch–ANSI Standard (Stem Diameter 3/8")Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
.0001" .025" 1802F-10 .01" 0-10 ±.0001" ±.0002"
1803F-10 .01" 0-5-0 ±.0001" ±.0002"
.00025" .05" 1470F .02" 0-20 ±.00025" ±.00025"
1470F-10 .02" 0-20 ±.00025" ±.00025"
1471F .02" 0-10-0 ±.00025" ±.00025"
.2" 1476F .02" 0-20 ±.00025" ±.0005"
.0005" .075" 1570F-10 .03" 0-30 ±.0005" ±.0005"
1571F-10 .03" 0-15-0 ±.0005" ±.0005"
.1" 1670F .04" 0-40 ±.0005" ±.0005"
1671F .04" 0-20-0 ±.0005" ±.0005"
1671F-10 .04" 0-20-0 ±.0005" ±.0005"
.125" 1506F .05" 0-50 ±.0005" ±.0005"
1507F .05" 0-25-0 ±.0005" ±.0005"
1507F-10 .05" 0-25-0 ±.0005" ±.0005"
.001" .05" 1400F-10 .02" 0-20 ±.0005" ±.001"
1401F-10 .02" 0-10-0 ±.0005" ±.001"
.075" 1580F-10 .03" 0-30 ±.0005" ±.001"
1581F-10 .03" 0-15-0 ±.0005" ±.001"
.1" 1404F-10 .04" 0-40 ±.0005" ±.001"
1405F-10 .04" 0-20-0 ±.0005" ±.001"
.125" 1780F .05" 0-50 ±.001" ±.001"
1781F .05" 0-25-0 ±.001" ±.001"
1781F-10 .05" 0-25-0 ±.001" ±.001"
.25" 1410F .1" 0-100 ±.001" ±.001"
1410F-10 .1" 0-100 ±.001" ±.001"
1411F .1" 0-50-0 ±.001" ±.001"
The measuring force for all of the above indicators is 1.4N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat-back version add ‘B’ to the order number, e.g. 1802B-10.
SpecificationsDial Indicators
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/INCH
R-57
R- 057 (2003) full size 12/9/03 1:05 PM Page 1
Dial Indicators / Group 1Inch
1803F-10 1470 1571F-10 1671
1506F 1507F 1410F 1411F
0 123
NO.1571-10 ®
.0005"
JEWELED
0
55
1010
15
_ + 055
1010
151520
10
23NO.1671
.0005"
_ +0 1 23
456
7891011
1213
141516
1718 19
01
2 3
01
2 3
.00025
NO.1470 ®NO.1803-10 ®
.0001"
011
22
33
445
_ +
JEWELED
NO.1410 ®
.001"
010
20
30
4050
60
70
80
90
21
0
NO.1411 ®
.001"
01010
2020
3030
404050
21
0
_ +
0
123
05
10
15
2025
30
35
40
45
NO.1506 ®
.0005"
0
123
05
10
15
2025
20
15
10
5
NO.1507 ®
.0005"
+_
Dial Indicator FacesGroup 1 – Inch
DimensionsOrder No. A B C1802F-10 1.65” .31” 1.09”1803F-10 1.65” .31” 1.09”1470 1.69” .36” 1.09”1470-10 1.69” .36” 1.09”1471 1.69” .36” 1.09”1476 1.91” .59” 1.28”1570F-10 1.71” .38” 1.09”1571F-10 1.71” .38” 1.09”1670 1.73” .40” 1.27”1671 1.73” .40” 1.27”1671-10 1.73” .40” 1.27”1506F 1.77” .44” 1.09”1507F 1.77” .44” 1.09”1507-10 1.77” .44” 1.09”1400-10 1.65” .36” 1.09”1401-10 1.65” .36” 1.09”1580-10 1.71” .38” 1.09”1581-10 1.71” .38” 1.09”1404F-10 1.73” .40” 1.27”1405F-10 1.73” .40” 1.27”1780 1.77” .44” 1.09”1781 1.77” .44” 1.09”1781-10 1.77” .44” 1.09”1410F 1.89” .56” 1.27”1410-10 1.89” .56” 1.27”1411F 1.89” .56” 1.27”
.59" .75"
ø.31"ø.26"
.25"
0-.001ø.375"
#4-48 Threads
.26"
AC
B.5
3"ø
1.61
"
.63"
1.50
"
Unit: Inch (mm)
DIAL INDICATORS/INCH
R-58
R- 058 (2003) full size 12/9/03 1:16 PM Page 1
Dial Indicators / Group 1Metric
SpecificationsMetric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
Metric–ISO/JIS Standard (Stem Diameter 8mm)
Total Range Dial AccuracyGraduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
0.002mm 0.5mm 1010-11 0.2mm 0-20 ±0.002mm1011-11 0.2mm 0-10-0 ±0.002mm
0.01mm 2.5mm 1230-01 1mm 0-100 ±0.01mm1231-01 1mm 0-50-0 ±0.01mm
5mm 1044-01 1mm 0-100 ±0.01mm ±0.013mm1045-01 1mm 0-50-0 ±0.01mm ±0.013mm
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features
0.001mm 1mm 1109F 0.2mm 0-100-0 ±0.007mm0.002mm 1mm 1013F 0.2mm 0-100-0 ±0.01mm0.005mm 3.5mm 1124F 0.5mm 0-50 ±0.013mm0.01mm 3.5mm 1040F 0.5mm 0-50 ±0.013mm
1041F 0.5mm 0-25-0 ±0.013mm4mm 1003 1mm 0-50-0 ±0.013mm5mm 1044F 1mm 0-100 ±0.013mm
1044F-60 1mm 0-100 ±0.013mm1044F-10 1mm 0-100 ±0.013mm1045F 1mm 0-50-0 ±0.013mm
The measuring force for all of the above indicators is 1.4N or less, except for the following; 1044F-10; 0.4N or less 1003, 1013F, 1040F, 1041F, 1044F, 1045F, 1109F; 1.5Nor less 1044F-60; 2.0N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat back version add ‘B’ to the order number, e.g. 1003B.*ISO/JIS Type gages accuracy includes uncertainty k=2.
1044-01
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/INCH
R-59
R- 059 (2003) full size 12/9/03 1:16 PM Page 1
Dial Indicators / Group 1Metric
Dial Indicator FacesGroup 1 – Metric
Dimensions Dimensions
0 1122
334455
6677
8899 10
_ + _ +
01
2 3
01
2 3
NO.1011
2µm
JEWELED
NO. 1040F ®
0.01mm
01
2 3NO. 1041F ®
0.01mm
0
45
40
35
30
25
20
15
10
5
05
10
15
2025
30
35
40
450
55
1010
1515
202025
1011-11 1040F 1041F 1230-01
100
10
2020
3030
404050
_ +
NO.1231 ®
0.01mm
1
0
23
NO.1044 ®
0.01mm
010
20
30
4050
60
70
80
90
0
1234
5
090
80
70
60
50
40
30
20
10
NO.1230 ®
0.01mm
010
20
30
4050
60
70
80
90
0
123
1231-01 1044-01
100
10
2020
3030
404050
_ +
NO.1045 ®
0.01mm
0
1234
5
1045-01
.59" .75"
ø.31"ø.26"
.25"
0-.001ø.375"
#4-48 Threads
.26"
AC
Bø
1.61
"
.63"
1.50
"
.53"
ANSI Standard
Unit: Inch
Metric Standard
0 -0.009
M2.5x0.45
32.5
B13
A
14.5
7
16
Ø6.5
Ø8
5
20
Ø41
Unit: mm
Unit: mm
1003
0 -0.009
20
129.
5
39.5
13
5.3
13
Ø6.5
Ø8
5
15
Ø36
M2.5 x 0.45
ANSI StandardOrder No. A B C1010-11 1.62” .29” 1.51”1011-11 1.62” .29” 1.51”1230-01 1.73” .40” 1.27”1231-01 1.73” .40” 1.27”1044-01 1.85” .52” 1.27”1045-01 1.85” .52” 1.27”
Metric Standard Unit: mmOrder No. A B1109F 49 15.51013F 49 15.51124F 46 12.51040F 46 12.51041F 46 12.51044F 47.5 141044F-10 47.5 141044F-60 57 251045F 47.5 14
DIAL INDICATORS/METRIC
R-60
R- 060 (2003) full size 12/9/03 1:17 PM Page 1
Dial Indicators / Group 2Inch
2803F-10
Inch–ANSI Standard (Stem Diameter 3/8")Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
.0001" .02" 2937F-10 .008" 0-4-0 ±.0001" ±.0001"2938F-10 .008" 0-8 ±.0001" ±.0001"
.025" 2802F-10 .01" 0-10 ±.0001" ±.0002"2802F-60 .01" 0-10 ±.0001" ±.0002"2803F-10 .01" 0-5-0 ±.0001" ±.0002"2803F-60 .01" 0-5-0 ±.0001" ±.0002"
.05" 2804F-10 .01" 0-10 ±.0001" ±.0002"2805F-10 .01" 0-5-0 ±.0001" ±.0002"2805F-80 .01" 0-5-0 ±.0001" ±.0002"2905F-10 .01" 10-0 ±.0001" ±.0002"2923F-10 .01" 0-5-0 ±.0001" ±.0002"
.1" 2806F-10 .01" 0-10 ±.0001" ±.0003"2806F-60 .01" 0-10 ±.0001" ±.0003"
.25" 2356-50 .01" 0-10 ±.0002" ±.0005"
.5" 2358-50 .01" 0-10 ±.0002" ±.0008".00025" .025" 2600F-10 .01" 0-10 ±.00025" ±.00025"
2601F-10 .01" 0-5-0 ±.00025" ±.00025".05" 2470-50 .02" 0-20 ±.00025" ±.00025"
2471-50 .02" 0-10-0 ±.00025" ±.00025".24" 2476F-60 .02" 0-20 ±.00025" ±.00025"
.0005" .05" 2500F-10 .02" 0-20 ±.0005" ±.0005"2501F-10 .02" 0-10-0 ±.0005" ±.0005"
.075" 2570F-10 .03" 0-30 ±.0005" ±.0005"2570F-60 .03" 0-30 ±.0005" ±.0005"2571F-10 .03" 0-15-0 ±.0005" ±.0005"2571F-60 .03" 0-15-0 ±.0005" ±.0005"
.1" 2670F .04" 0-40 ±.0005" ±.0005"2670F-10 .04" 0-40 ±.0005" ±.0005"2671F .04" 0-20-0 ±.0005" ±.0005"2671F-10 .04" 0-20-0 ±.0005" ±.0005"
.125" 2506F .05" 0-50 ±.0005" ±.0005"2506F-10 .05" 0-50 ±.0005" ±.0005"2507F .05" 0-25-0 ±.0005" ±.0005"2507F-10 .05" 0-25-0 ±.0005" ±.0005"2906F .05" 50-0 ±.0005" ±.0005"2922F .05" 0-25-0 ±.0005" ±.0005"
.3" 2576F-60 .03" 0-30 ±.0005" ±.001"
.4" 2675F .04" 0-20-0 ±.0005" ±.0015"
.5" 2514F .05" 0-50 ±.0005" ±.0015"2514F-60 .05" 0-50 ±.0005" ±.0015"
1" 2776F .05" 0-50 ±.0005" ±.002"2776F-60 .05" 0-50 ±.0005" ±.002"
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/INCH
R-61
R- 061 (2003) full size 12/9/03 1:19 PM Page 1
Dial Indicators / Group 2Inch
SpecificationsInch–ANSI Standard (Stem Diameter 3/8")
Total Range Dial AccuracyGraduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features.001" .05" 2400F-10 .02" 0-20 ±.0005" ±.001"
2401F-10 .02" 0-10-0 ±.0005" ±.001".1" 2404F-10 .04" 0-40 ±.0005" ±.001"
2405F-10 .04" 0-20-0 ±.0005" ±.001".125" 2780F .05" 0-50 ±.001" ±.001"
2780F-10 .05" 0-50 ±.001" ±.001"2781F .05" 0-25-0 ±.001" ±.001"2781F-10 .05" 0-25-0 ±.001" ±.001"
.25" 2410F .1" 0-100 ±.001" ±.001"2410F-10 .1 0-100 ±.001" ±.001"2410F-60 .1" 0-100 ±.001" ±.001"2919F-10 .1" 0-100 ±.001" ±.001"2411F .1" 0-50-0 ±.001" ±.001"2411F-10 .1" 0-50-0 ±.001" ±.001"2920F-10 .1" 0-50-0 ±.001" ±.001"
.4" 2412F .1" 0-100 ±.001" ±.001"2412F-60 .1" 0-100 ±.001" ±.001"2412F-80 .1" 0-100 ±.001" ±.001"2413F .1" 0-50-0 ±.001" ±.001"2903F .1" 100-0 ±.001" ±.001"
.5" 2414F .1" 0-100 ±.001" ±.001"2414F-10 .1" 0-100 ±.001" ±.001"2414F-60 .1" 0-100 ±.001" ±.001"2915F-10 .1" 0-100 ±.001" ±.001"2415F .1" 0-50-0 ±.001" ±.001"2415F-10 .1" 0-50-0 ±.001" ±.001"2415F-60 .1" 0-50-0 ±.001" ±.001"2918F-10 .1" 0-50-0 ±.001" ±.001"
1" 2416F .1" 0-100 ±.001" ±.002"2416F-06 .1" 0-100 ±.001" ±.002"2416F-10 .1" 0-100 ±.001" ±.002"2416F-60 .1" 0-100 ±.001" ±.002"2417F .1" 0-50-0 ±.001" ±.002"2904F .1" 100-0 ±.001" ±.002"
2" 2424-10 .1" 0-100 ±.001" ±.003".01" 1" 2204F 1" 0-1000 – ±.005"The measuring force for all of the above indicators is 1.5N or less, except for the following: 2424-10; 2.0N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat-back version add ‘B’ to the order number, e.g. 2937FB-10. All waterproof indicators: 3.0N or less.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/INCH
R-62
R- 062 (2003) full size 12/9/03 1:20 PM Page 1
Dial Indicators / Group 2Inch
Dial Indicator FacesGroup 2 – Inch
2937F-10 2802F-10 2803F-10 2358-50 2356-50
2470-50 2506F 2507F 2571F-10 2570F-10
2514F 2922F 2670F 2671F 2780F
2781F 2404F-10 2410F 2411F 2416F, 2416F-10, 2416F-60
2904F 2919F-10 2424-10
012
3
®
.0001"
6 J E W E L S
011
22
33
445
_ +
SHOCK P ROOF012
3
.0001"
6 J E W E L S
011
22
334
_ +
NO. 2937F-10
012
3
.0001"
6 J E W E L S
019
28
37
465
_ +
.0001"
J E W E L E D
019
28
37
465
.25
.2.15
.1
.050
NO. 2356-50
.0001"
J E W E L E D
019
28
37
465
.5
.4.3
.2
.10
0 98
7654
3
21
NO. 2358-50
012
3
.00025"
J E W E L E D
NO. 2470 -50 ®
12
3456
78
9101112
13141516
1718
19 0
SHOCK P ROOF
.0005"
012
3
0545
_
1040
1535
203025
+
SHOCK P ROOF
.0005"
012
3
055
1010
1515
202025
_ +
®
J E W E L E D
.0005"
0
55
1010
15
0123
_ +
J E W E L E D
.0005"
0
5
10
15
20
25
0123
S H O C K P R O O F
.0005"
0
. 1
. 2 . 3
. 4
0545
1040
1535
203025
S H O C K P R O O F
.0005"
055
1010
1515
202025
01
2 3
_+
S H O C K P R O O F
®
.0005"
05
10
1520
25
30
35
012
3
S H O C K P R O O F
.0005"
055
1010
151520
012
3
_ + 05
10
15
2025
30
35
40
45
.001"
012
3
S H O C K P R O O F
055
1010
1515
202025
.001"
012
3
S H O C K P R O O F
_ +
®
090 10
80 20
70 30
60 4050
NO. 2410F
.001"
0
1
2
3
01010
2020
3030
404050
NO. 2411F
.001"
0
1
2
3
_ +
012
34 5 6
7
89
.001"
010
20
30
4050
60
70
80
900
90
80
70
60
50
40
30
20
10
NO. 2904F
.001"
01
2
34
56
7
8
9
09010
8020
7030
604050
090 10
80 20
70 30
60 4050
NO. 2919-10.001"
JEWELED
3 0 2 1
NO. 2424-10.001"
010
20
30
4050
60
70
80
900
90
80
70
60
50
40
30
20
10
MADE IN JAPAN
0
1
2
1
2.1
.1
.2
.2
.3
.3
.4
.4.5.5
.6
.6
.7
.7
.8
.8
.9
.9
.1
.1
.2
.2
.3
.3
.4
.4
.5.5
.6
.6
.7
.7
.8
.8
.9
.9
0
DIAL INDICATORS/INCH
R-63
R- 063 (2003) full size 12/9/03 1:21 PM Page 1
Dial Indicators / Group 2Inch
Dimensions
Dimensions
0-.001
F .75"
ø.26"
.375"
#4-48 Threads
H
AD
BC
E .63" G
.25"
.59 " .75"
(.69")
ø.26"
.375" 0-.001
#4-48 Threads
.30"
AD
BC
2.19
" (2
.28"
)
.63"
2.05
" (2
.13"
)
.25"
Order No. A B C D E F G H2937F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2938F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2802F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2802F-60 2.15” .75” .31” 1.55” 2.19” .59” 2.05” .30”2803F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2803F-60 2.15” .75” .31” 1.55” 2.19” .59” 2.05” .30”2804F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2805F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2805F-80* 2.07” .39” .59” 2.32” 2.19” .61” 2.05” .30”2905F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2923F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2806F-10 2.14” .46” .59” 1.78” 2.19” .59” 2.05” .30”2806F-60 2.15” .79” .27” 1.55” 2.19” .59” 2.05” .30”2356-50 2.28” .61” .53” 1.84” 2.28” .69” 2.13” .35”2358-50 2.52” .85” .53” 2.04” 2.28” .69” 2.13” .35”2600F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2601F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2470-50 2.07” .40” .53” 1.84” 2.28” .69” 2.13” .35”2471-50 2.07” .40” .53” 1.84” 2.28” .69” 2.13” .35”2476F-60 2.26” .89” .27” 1.78” 2.19” .59” 2.05” .30”2500F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2501F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”2570F 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30”2570F-10 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30”2570F-60 2.11” .74” .27” 1.78” 2.19” .59” 2.05” .30”2571F 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30”2571F-10 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30”2571F-60 2.11” .74” .27” 1.78” 2.19” .59” 2.05” .30”2576F-60 2.33” .97” .27” 1.78” 2.19” .59” 2.05” .30”2670F 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30”2670F-10 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30”2671F 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30”2671F-10 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30”2675F* 2.45” .77” .59” 1.46” 2.19” .59” 2.05” .30”2506F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30”2506F-10 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30”2507F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30”2507F-10 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30”2906F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30”2922F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30”2514F 2.55” .87” .59” 1.46” 2.19” .59” 2.05” .30”2514F-60 2.56” 1.20” .27” 1.78” 2.19” .59” 2.05” .30”2776F* 3.05” 1.37” .59” 1.46” 2.19” .59” 2.05” .30”2776F-60 3.18” 1.81” .27” 2.37” 2.19” .59” 2.05” .30”*Denotes the indicator does not feature a cap (dimension ‘D’ is taken to thescrew top, which rises with the spindle).
Order No. A B C D2400F-10 2.07” .39” .59” 1.78”2401F-10 2.07” .39” .59” 1.78”2404F-10 2.12” .44” .59” 1.90”2405F-10 2.12” .44” .59” 1.90”2780F 2.15” .47” .59” 1.78”2780F-10 2.15” .47” .59” 1.78”2781F 2.15” .47” .59” 1.78”2781F-10 2.15” .47” .59” 1.78”2410F 2.30” .62” .59” 1.55”2410F-10 2.30” .62” .59” 1.55”2410F-60 2.30” .94” .27” 1.55”2919F-10* 2.51” .83” .59” 1.98”2411F 2.30” .62” .59” 1.55”2411F-10 2.30” .62” .59” 1.55”2920F-10 2.51” .83” .59” 1.98”2412F* 2.45” .77” .59” 1.46”2412F-60 2.45” 1.09” .27” 1.78”2412F-80* 2.45” .77” .59” 2.32”2413F* 2.45” .77” .59” 1.46”2903F* 2.45” .77” .59” 1.46”2414F* 2.56” .88” .59” 1.46”2414F-10* 2.56” .88” .59” 1.46”2414F-60 2.56” 1.20” .27” 1.78”2915F-10* 2.51” .83” .59” 1.98”2415F* 2.56” .88” .59” 1.46”2415F-10* 2.56” .88” .59” 1.46”2415F-60 2.56” 1.20” .27” 1.78”2918F-10* 2.51” .83” .59” 1.98”2416F* 3.05” 1.37” .59” 1.46”2416F-06* 3.05” 1.37” .59” 1.46”2416F-10* 3.05” 1.37” .59” 1.46”2416F-60* 3.18” 1.81” .27” 2.37”2417F* 3.05” 1.37” .59” 1.46”2904F* 3.05” 1.37” .59” 1.46”2424-10 5.47” 2.33” 2.04” 4.67”2204F* 3.05” 1.37” .59” 1.46”*Denotes the indicator does not feature a cap (dimension ‘D’ is taken to thescrew top, which rises with the spindle).
DIAL INDICATORS/INCH
R-64
R- 064 (2003) full size 12/9/03 1:22 PM Page 1
Dial Indicators / Group 2Metric ANSI
SpecificationsMetric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
2046F-01
Total Range Dial AccuracyGraduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Rev Features0.001mm 1mm 2109F-11 0.2mm 0-100-0 ±0.002mm ±0.003mm
5mm 2119-51 0.2mm 0-10-0 ±0.005mm ±0.008mm0.002mm 0.5mm 2010F-11 0.2mm 0-20 ±0.002mm
2010F-61 0.2mm 0-20 ±0.002mm2011F-11 0.2mm 0-10-0 ±0.002mm2011F-61 0.2mm 0-10-0 ±0.002mm
0.005mm 1.25mm 2120F-11 0.5mm 0-50 ±0.005mm2120-71 0.5mm 0-50 ±0.005mm2121F-11 0.5mm 0-25-0 ±0.005mm2121-71 0.5mm 0-25-0 ±0.005mm
0.01mm 2.5mm 2230F-01 1mm 0-100 ±0.010mm2230F-11 1mm 0-100 ±0.010mm2231F-01 1mm 0-50-0 ±0.010mm2231F-11 1mm 0-50-0 ±0.010mm
5mm 2044F-01 1mm 0-100 ±0.010mm ±0.010mm2044F-61 1mm 0-100 ±0.010mm ±0.010mm2045F-01 1mm 0-50-0 ±0.010mm ±0.010mm2045F-61 1mm 0-50-0 ±0.010mm ±0.010mm
10mm 2046F-01 1mm 0-100 ±0.010mm ±0.013mm2046F-11 1mm 0-100 ±0.010mm ±0.013mm2046F-61 1mm 0-100 ±0.010mm ±0.013mm2047F-01 1mm 0-50-0 ±0.010mm ±0.013mm2047F-11 1mm 0-50-0 ±0.010mm ±0.013mm2048F-01 1mm 0-100 ±0.010mm ±0.015mm2048F-11 1mm 0-100 ±0.010mm ±0.015mm2902F-01 1mm 100-0 ±0.010mm ±0.013mm
20mm 2050F-01 1mm 0-100 ±0.010mm ±0.020mm2050F-11 1mm 0-100 ±0.010mm ±0.020mm
25mm 2056F-01 1mm 0-100 ±0.010mm ±0.025mm0.02mm 5mm 2032F-11 2mm 0-200 ±0.020mm
2033F-11 2mm 0-100-0 ±0.020mmThe measuring force for all of the above indicators is 1.5N or less except for the following: 2050F-01, 2050F-11, 2056F-01; 2.0N or less, 2045F-61, 2046F-61; 2.5N or less. The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard: for flat back version of indicator add ‘B’ to the order number, e.g. 2046FB-11.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/METRIC
R-65
R- 065 (2003) full size 12/9/03 1:22 PM Page 1
Dial Indicator FacesGroup 2 – Metric ANSI
Dial Indicators / Group 2Metric ANSIDimensions
ANSI Standard
0 1122
334455
6677
8899 10
_ +
2µm
012
3
SHOCK P ROOF6 J E W E L S
0 1122
334455
6677
8899 10
1µm
0
. 2. 4. 6
. 8
1.0
SHOCK P ROOF6 J E W E L S
0 119218
317416515
614713
812911 10
2µm
012
3
SHOCK P ROOF6 J E W E L S
_ +
SHOCK P ROOF
0.01mm
01010
2020
3030
404050
_ +
SHOCK P ROOF
0.01mm
90
80
70
60
010
20
30
4050
01
2
34
5 6
7
8
9 01
2
34
5 6
7
8
9 0.01mm
090 10
80 20
70 30
60 4050
J E W E L E D
109
87
6 5 43
210
SHOCK P ROOF
0.01mm
010 10
20 20
30 30
40 4050
012
3
_ +
2011F-11 2010F-11 2109F-11 2231F-01
2046F-01, 2046F-11 2047F-01, 2047F-11 2048F-01, 2048F-11
.59" .75"
ø.26"
.375" 0-.001
#4-48 Threads
.30"(35")
AD
BC
2.19
" (2
.28"
)
.63"
2.05
" (2
.13"
)
.25"
(.69") (.78")
( ): 2119-51 Model
ANSI StandardOrder No. A B C D2109F-11 2.04” .36” .59” 1.78”2119-51 2.22” .55” .53” 1.84”2010F-11 2.04” .36” .59” 1.78”2010F-61 2.15” .75” .31” 1.55”2011F-11 2.04” .36” .59” 1.78”2011F-61 2.15” .75” .31” 1.55”2120F-11 2.06” .38” .59” 1.55”2120-71 2.09” .70” .24” 1.84”2121F-11 2.06” .38” .59” 1.55”2121-71 2.09” .70” .24” 1.84”2230F-01 2.15” .47” .59” 1.78”2230F-11 2.15” .47” .59” 1.78”2231F-01 2.15” .47” .59” 1.78”2231F-11 2.15” .47” .59” 1.78”2044F-01 2.24” .56” .59” 1.78”2044F-61 2.24” .88” .27” 1.78”2045F-01 2.24” .56” .59” 1.78”2045F-61 2.24” .88” .27” 1.78”2046F-01 2.45” .77” .59” 1.90”2046F-11 2.45” .77” .59” 1.90”2046F-61 2.45” 1.09” .27” 1.79”2047F-01 2.45” .77” .59” 1.90”2047F-11 2.45” .77” .59” 1.90”2048F-01 2.40” .71” .59” 1.87”2048F-11 2.40” .71” .59” 1.87”2902F-01 2.45” .77” .59” 1.90”2050F-01* 2.87” 1.19” .59” 1.46”2050F-11* 2.87” 1.19” .59” 1.46”2056F-01* 3.05” 1.37” .59” 1.46”2032F-11 2.24” .56” .59” 1.78”2033F-11 2.24” .56” .59” 1.78”*Denotes the indicator does not feature a cap (dimension ‘D’ is takento the screw top, which rises with the spindle).
DIAL INDICATORS/METRIC
R-66
R- 066 (2003) full size 12/9/03 1:23 PM Page 1
Dial Indicators / Group 2Metric StandardSpecificationsMetric–ISO/JIS Standard (Stem Diameter 8mm, Limit Hand is standard accessory)
2046F
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features0.001mm 1mm 2110F 0.1mm 0-100 ±0.005mm
2110F-60 0.1mm 0-100 ±0.005mm2109F 0.2mm 0-100-0 ±0.005mm2109F-60 0.2mm 0-100-0 ±0.005mm
2mm 2113F 0.2mm 0-100-0 ±0.007mm5mm 2118F 0.2mm 0-100-100 ±0.01mm
2119F 0.2mm 0-100-0 ±0.01mm0.005mm 5mm 2124F 0.5mm 0-50 ±0.012mm
2125F 0.5mm 0-25-0 ±0.012mm0.01mm 5mm 2044F 1mm 0-100 ±0.012mm
2044FE-09 1mm 0-100 ±0.013mm2044F-60 1mm 0-100 ±0.012mm2045FE 1mm 0-50-0 ±0.012mm2045F-60 1mm 0-50-0 ±0.012mm
10mm 2046F 1mm 0-100 ±0.013mm2046FE 1mm 0-100 ±0.013mm2046F-60 1mm 0-100 ±0.013mm2046FE-09 1mm 0-100 ±0.015mm2046F-69 1mm 0-100 ±0.015mm2046FE-10 1mm 0-100 ±0.015mm2047FE 1mm 0-50-0 ±0.013mm2310FE 1mm 0-100 ±0.015mm2902FE 1mm 100-0 ±0.013mm
20mm 2050F-60 1mm 0-100 ±0.02mm2050FE 1mm 0-100 ±0.02mm2320FE 1mm 0-100 ±0.02mm
30mm 2052FE 1mm 0-100 ±0.025mm2330FE 1mm 0-100 ±0.025mm2952FE 1mm 100-0 ±0.025mm
The measuring forces for all of the above indicators is 1.5N or less, except for the following:2119F, 2125F, 2044F; 0.5N or less, 2046FE-10; 0.8N or less, 2050FE, 2320FE; 2.0N or less,2052-FE, 2330FE, 2952FE; 2.2N or less, 2110F-60, 2109F-60, 2044F-60, 2045F-60, 2046F-60, 2046F-69, 2050F-60; 2.5N or less. The conversion factor between Newton force and gram force is 1N=101.94gf. Lug back isstandard; for flat back version add ‘B’ to the order number, e.g. 2046FB.Accuracy includes uncertainty k=2.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/METRIC
R-67
R- 067 (2003) full size 12/9/03 1:24 PM Page 1
Dial Indicators / Group 2Metric Standard
Dial Indicator FacesGroup 2 – Metric Standard
Dimensions
2110F 2124F
0.1.2.3.4
.5 .6 .7.8.9
1.0
1µm
010
20
30
4050
60
70
80
900
90
80
70
60
50
40
30
20
10
6 J E W E L S
5µm
0
1
2 3
4
0545
1040
1535
203025
J E W E L E D
0
5 45
10 40
15 35
20 30
25
Metric Standard Unit: mmOrder No. A B C D E2110F 66.5 21.2 17.5 46.8 172110F-60 67.5 26.7 13 46.8 172109F 60.3 15 17.5 46.8 172109F-60 65 24.2 13 46.8 172113F 60.8 15.5 17.5 46.8 172118F 60 14.7 17.5 46.8 172119F 60 14.7 17.5 46.8 172124F 60 14.7 17.5 46.8 172044F 64.8 19.5 17.5 46.8 16.52044FE-09 64.8 19.5 17.5 46.8 16.52044F-60 64.8 25 13 46.8 16.52045FE 64.8 19.5 17.5 46.8 16.52045F-60 65.8 25 13 46.8 16.52046F 64.8 19.5 17.5 46.8 16.52046FE 64.8 19.5 17.5 46.8 16.52046F-60 69.5 28.7 13 46.8 16.52046FE-09 64.8 19.5 17.5 46.8 16.52046F-69 69.5 28.7 13 46.8 16.52046FE-10 64.8 19.5 17.5 46.8 172047FE 64.8 19.5 17.5 46.8 16.52310FE 64.8 19.5 17.5 46.8 172902FE 64.8 19.5 17.5 46.8 16.52050F-60 87 46.2 13 55.5 16.52050FE* 75 29.7 17.5 40 16.52320FE* 75 29.7 17.5 40 172052FE* 88.5 43 17.5 40 16.52330FE* 88.5 43 17.5 40 172952FE* 88.5 43 17.5 40 16.5*Denotes the indicator does not feature a cap (dimension ‘D’ is taken to thescrew top, which rises with the spindle).
0-0.009
E 20
ø6.5
ø8
M2.5x0.45
8
AD
BC
ø55
.6
16
ø52
5
Metric Standard
Unit: mm
DIAL INDICATORS/METRIC
R-68
R- 068 (2003) full size 12/9/03 1:24 PM Page 1
Dial Indicators / Group 3Inch
SpecificationsInch–ANSI Standard (Stem Diameter 3/8")
3571
Total Range Dial AccuracyGraduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
.0001" .025" 3802-10 .01" 0-10 ±.0001" ±.0002"
3803-10 .01" 0-5-0 ±.0001" ±.0002"
.0005" .075" 3570 .03" 0-30 ±.0005" ±.0005"
3571-10 .03" 0-15-0 ±.0005" ±.0005"
.001" .125" 3780 .05" 0-50 ±.001" ±.001"
3781 .05" 0-25-0 ±.001" ±.001"
.25" 3410 .1" 0-100 ±.001" ±.001"
3411 .1" 0-50-0 ±.001" ±.001"
.4" 3412 .1" 0-100 ±.001" ±.001"
3413 .1" 0-50-0 ±.001" ±.001"
1" 3416 .1" 0-100 ±.001" ±.002"
3417 .1" 0-50-0 ±.001" ±.002"
2" 3424-10 .1" 0-100 ±.001" ±.003"
3" 3426-10 .1" 0-100 ±.001" ±.005"
4" 3428-10 .1" 0-100 ±.001" ±.005"The measuring force for all of the above indicators is 1.5N or less, except for the following:3424-10; 2.1N or less: 3426-10; 3.0N or less: 3428-10; 4.0N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat-back version add ‘B’ to the order number, e.g. 3802B-10.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/INCH
R-69
R- 069 (2003) full size 12/9/03 1:25 PM Page 1
Dial Indicators / Group 3Inch
Dial Indicator FacesGroup 3 – Inch
Dimensions
3802-10 3571 3780
3412 3413 3424-10
.001"
05
10
15
2025
30
35
40
45
01
2
3
01
2
3
NO. 3 7 8 001
2
3
NO.3571 ®
.0005"
JEWELED
MADE IN JAPAN MADE IN JAPAN
SHOCK PROOF
J E W E L S
0
55
1010
15
_ +
NO. 3 8 02 -10 ®
.0001"
01
2
3
45
6
7
8
9
6
.63" .75"
ø26"
0-.001
.25"
ø.375"
#4-48 Threads
.33"
AD
BC
ø2.
97"
.63"
2.76
"
Order No. A B C D3802-10 2.28” .32” .59” 2.14”3803-10 2.28” .32” .59” 2.14”3570 2.32” .36” .59” 2.14”3571 2.32” .36” .59” 2.14”3780 2.39” .42” .48” 2.14”3781 2.39” .42” .48” 2.14”3410 2.56” .77” .59” 2.14”3411 2.56” .77” .59” 2.14”3412 2.72” .75” .59” 2.14”3413 2.72” .75” .59” 2.14”3416* 3.30” 1.33” .59” 1.83”3417* 3.30” 1.33” .59” 1.83”3424-10 5.79” 2.30” 2.01” 5.04”3426-10 7.32” 3.41” 2.43” 6.57”3428-10 9.33” 4.42” 3.43” 8.03”*Denotes the indicator does not feature a cap (dimension ‘D’ is taken
to the screw top, which rises with the spindle).
DIAL INDICATORS/INCH
R-70
R- 070 (2003) full size 12/9/03 1:25 PM Page 1
Dial Indicator FacesGroup 3 – Metric
Dial Indicators / Group 3Metric
SpecificationsMetric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
3010-11
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features
0.001mm 1mm 3109F 0.2mm 0-100-0 ±0.006mm0.01mm 10mm 3046F 1mm 0-100 ±0.015mm
3047F 1mm 0-50-0 ±0.015mm20mm 3050F 1mm 0-100 ±0.020mm30mm 3052F 1mm 0-100 ±0.025mm50mm 3058F 1mm 0-100 ±0.035mm80mm 3060F 1mm 0-100 ±0.045mm100mm 3062F 1mm 0-100 ±0.050mm
The measuring force for all of the above indicators is 1.5N or less, except for: 3046F, 3047F; 1.4N or less, 3050F; 2.0 or less, 3052-01, 3052-11, 3052F; 2.2N or less, 3058-01, 3058-11,3058F; 2.5N or less, 3060F; 2.7N or less, 3062F; 3.2N or less. The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat back version add ‘B’ to the order number, e.g. 3052FB.ISO/JIS type gages accuracy includes uncertainty k=2.
Total Range Dial AccuracyGraduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
0.002mm 0.5mm 3010-11 0.2mm 0-20 ±0.002mm3011-11 0.2mm 0-10-0 ±0.002mm
0.01mm 2.5mm 3230-01 1mm 0-100 ±0.010mm3231-01 1mm 0-50-0 ±0.010mm
30mm 3052-01 1mm 0-100 ±0.010mm ±0.025mm3052-11 1mm 0-100 ±0.010mm ±0.025mm
50mm 3058-01 1mm 0-100 ±0.015mm ±0.035mm3058-11 1mm 0-100 ±0.015mm ±0.035mm
Metric–ISO/JIS Standard (Stem Diameter 8mm)
3011-11 3010-11 3109F 3046F
0 1122
334456
56
7788
99 10
_ +
2µm
012
3
S H O C K P R O O F6
NO. 3011-11 ®J E W E L S
0 119218
317416
515614
713812
911 10
2µm
NO. 3010-11 ®01
2
3
S H O C K P R O O F6 J E W E L S
0 10102020
3030
4040
5050
6060
70708080
9090 100
1µm
0. 2
. 4 . 6. 81.0
MADE IN JAPAN
6 J E W E L S
NO. 3109 -10 ® NO. 3046 ®
0.01mm
010
20
30
4050
60
70
80
90 0
90
80
70
60
50
40
30
20
10
MADE IN JAPAN0
12
34
56
7
890 1
2
34
56
7
8
9
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/METRIC
R-71
R- 071 (2003) full size 12/9/03 1:26 PM Page 1
Dimensions Metric ANSI Standard
ISO/JIS Metric Standard
ISO/JISMetric Standard
.63" .75"
ø.26"
0-.001
.25"
ø.375"
#4-48 Threads
.33"
AD
BC
ø2.
95"
.63"
2.76
"
Metric ANSI StandardOrder No. A B C D3010-11 2.28” .31” .48” 2.09”
3011-11 2.28” .31” .48” 2.09”
3230-01 2.35” .39” .48” 2.14”
3231-01 2.35” .39” .48” 2.14”
3052-01* 4.00” 1.46” 1.05” 2.85”
3052-11* 4.00” 1.46” 1.05” 2.85”
3058-01* 5.47” 2.23” 1.76” 3.20”
3058-11* 5.47” 2.23” 1.76” 3.20”*Denotes the indicator does not feature a cap (dimension ‘D’ is takento the screw top, which rises with the spindle).
Unit: mm
Unit: mm
Unit: Inch
ISO/JIS Metric StandardOrder No. A B C D E3050F* 93 29 25 49 16.5
3052F* 104 40 25 73 17
3058F* 142 60 43 82 17
3060F* 203 91 73 112 17
3062F* 243 110 94 132 17Unit: mm
*Denotes the indicator does not feature a cap (dimension ‘D’ is takento the screw top, which rises with the spindle).
ø71
0 -0.009
M2.5x0.45
BC
AD
E
9
16
Ø6.5
Ø8
5
21
Ø78
ø71
0 -0.009
M2.5x0.45
BC
AD
E
9
16
Ø6.5
Ø8
5
21
Ø78
ISO/JIS Metric StandardOrder No. A B C D E3046F 75.5 21 15.5 56 16.5
3047F 75.5 21 15.5 56 16.5
3109F 79 15 25 56 17
Unit: mm
Dial Indicators / Group 3Metric
DIAL INDICATORS/METRIC
R-72
R- 072 (2003) full size 12/9/03 1:27 PM Page 1
Dial Indicators / Group 4Inch
SpecificationsInch–ANSI Standard (Stem Diameter 3/8")4802-10
Total Range Dial AccuracyGraduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
.0001" .025" 4802-10 .01" 0-10 ±.0001" ±.0002"
4803-10 .01" 0-5-0 ±.0001" ±.0002"
.05" 4818-10 .02" 0-20 ±.0003" ±.0003"
.0005" .075" 4570 .03" 0-30 ±.0005" ±.0005"
4571 .03" 0-15-0 ±.0005" ±.0005"
.001" .25" 4410 .1" 0-100 ±.001" ±.001"
4411 .1" 0-50-0 ±.001" ±.001"
3" 4887 .1" 0-100 ±.001" ±.005"The measuring force for all of the above indicators is 1.5N or less, except for the following:4887; 2.5N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for flat-back version add ‘B’ to the order number, e.g. 4802B-10
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/INCH
R-73
R- 073 (2003) full size 12/9/03 1:27 PM Page 1
Dial Indicators / Group 4Inch
Dial Indicator FacesGroup 4 – Inch
Dimensions
4803-10 4802-10 4570
NO. 4802 -10 ®
.0001"
01
2
3
45
6
7
8
9
012
3
6 J E W E L SSHOCK PROOF
NO. 4803 -10 ®
.0001"
011
22
33
445
012
3
6 J E W E L SSHOCK PROOF
_ +
012
3
NO. 4570
.0005"
J E W E L E D
0
525
1020
15
_ +
Order No. A B4802-10 2.64” .34”4803-10 2.64” .34”4818-10 2.66” .36”4570 2.66” .36”4571 2.66” .36”4410 2.87” .57”4411 2.87” .57”4887 7.24” 3.74”
.71" .75"
ø26"
0-.001
.25"
ø.375"
#4-48 Threads
.33"A
2.16
" (6
.26"
)
B.5
2" (
2.13
")ø
3.56
"
.63"
ø2.
76"
( ) 4887 Model
DIAL INDICATORS/INCH
R-74
R- 074 (2003) full size 12/9/03 1:30 PM Page 1
Dial Indicators / Group 4Metric
SpecificationsMetric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
4230-01
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features
0.01mm 10mm 4046 1mm 0-100 ±0.015mmThe measuring force of all of the above indicators is 1.5N or less, except for the following: 4046;1.4N or less. The conversion factor between Newton force and gram force is 1N=101.94gf.Lug back is standard; for the flat back version add ‘B’ to the order number, e.g. 4230B-01.4046 gages accuracy includes uncertainty k=2.
Metric–ISO/JIS Standard (Stem Diameter 8mm)
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
DIAL INDICATORS/METRIC
R-75
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features
0.01mm 2.5mm 4230-01 1mm 0-100 ±0.01mm4231-01 1mm 0-50-0 ±0.01mm
R- 075 (2003) full size 12/9/03 1:32 PM Page 1
Dial Indicators / Group 4Metric
Dial Indicator FacesGroup 4 – Metric
Dimensions Dimensions
4230-01 4046
NO. 4230-01
0.01mm
010
20
30
4050
60
70
80
90
012
3
NO.4230 - 01 NO. 4046
0.01mm
010
20
30
4050
60
70
80
900
90
80
70
60
50
40
30
20
10
M A D E I N J A P A N0
12
34
56
7
890 1
2
34
56
7
8
9
Metric ANSI Standard
.71" .78"
ø.26"
0-.001
.25"
ø.375"
#4-48 Threads
.33"
2.70
"2.
13"
.40"
.51"
ø3.
56"
.63"
ø2.
76"
4230-1, 4231-01
19 21
ø6.5
0-0.009
5
ø8
M2.5x0.45 Threads
9
8358
18.5
19ø
91 16 ø70
ISO/JIS Metric Standard
4046
Unit: mmUnit: Inch
DIAL INDICATORS/METRIC
R-76
R- 076 (2003) full size 12/9/03 1:35 PM Page 1
SPECIAL INDICATORS
One-Revolution Dial IndicatorsGroup 1&2
Order No. Group Graduation Range Dial Reading Accuracy Features1910-72 1 .0001" ±.003" 3–0–3 ±.0001"1909-62 1 .0005" ±.02" 20–0–20 ±.0005"2910-72 2 .0001" ±.004" 4–0–4 ±.0001"2947F-10 2 .0001" ±.004" 4–0–4 ±.0001"2909-62 2 .0005" ±.02" 20–0–20 ±.0005"2976* 2 .0005" .02" 10–0–10 ±.0005"2977* 2 .0005" .04" 20–0–20 ±.0005"2978* 2 .001" .06" 30–0–30 ±.001"2908-62 2 .001" ±.04" 40–0–40 ±.001"2945-40 2 .001" ±.04" 40–0–40 ±.001"2204F 2 .01" 1" 0–1000 ±.005"The measuring force for all the above indicators is 1.4N or less, except for: 2910-72, 2947F-10, 2908-62, 2945-40; 1.5N or less. 2204F; 2.0N or less. The conversion factor between Newton force and gram force is 1N=101.94gf.*Flat back type only.
To ensure fool-proof readings, Mitutoyo offers an “economical”, “One-Revolution” dial indicator which only allows one sweep of the dial hand forthe entire spindle travel.
Features• Bright red section of dial indicators no-reading zone.• Crystal face is hard coated for scratch resistance.• Limit hands supplied as standard accessory.
2976
Order No. Group Graduation Range Dial Reading Accuracy Features1900F-62 1 0.001mm ±0.05mm 50–0–50 ±0.005mm1929F 1 0.01mm 1mm 50–0–50 ±0.011mm1929F-62 1 0.01mm 1mm 50–0–50 ±0.011mm2900-73❈ 2 0.001mm ±0.05mm 50–0–50 ±0.0035mm2900F 2 0.001mm 0.1mm 50–0–50 ±0.0035mm2901F 2 0.001mm 0.16mm 80–0–80 ±0.005mm2971* 2 0.01mm 0.5mm 25–0–25 ±0.010mm2929F 2 0.01mm ±0.5mm 50–0–50 ±0.010mm2972* 2 0.01mm 1mm 50–0–50 ±0.012mm2973* 2 0.02mm 1.6mm 80–0–80 ±0.016mmThe measuring force for all the above indicators is 1.5N or less, except for: 2971, 2929F,2972, 2973; 1.4N or less. The conversion factor between Newton force and gram force is 1N=101.94gf. ❈ Stem diameter 3/8". *Flat back type only.ISO/JIS gages already include accuracy uncertainty, K=2.
SpecificationsInch–ANSI Standard (Stem Diameter 3/8")
Metric–ISO/JIS Standard (Stem Diameter 8mm)
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-77
R- 077 (2003) full size 12/9/03 1:35 PM Page 1
One-Revolution Dial IndicatorsGroup 2
Dimensions (Group 1) Dimensions (Group 2)
F
G E
C B
"0-0012".375
.19"
D
A
(Ø4.8)#4-48 THREAD(M2.5 X 0.95)
0 -0.009(Ø8 )
H.75"
ø.31"ø.26"
.25"
0-.001ø.375"
#4-48 Threads
H
AD
BC
E
.63" G
F
(20)
(ø8.5)(ø6.5)
(16)
(5)
(ø8.0 ) 0- 0.009
(M2.5 x 0.45)
110
22
33
_ +
.0001"
SHOCK PROOF
NO. 1910-72
055
1010
1515
2020
_ +
.0005"
S H O C K P R O O F
NO. 1909-62
055
1010
1515
2020
_ +
.0005"
SHOCK PROOF
NO. 2909-62
40 40.001"
010 10
20 20
30 30
SHOCK PROOF
NO. 2908-62
_ +
1910-72 1909-62 2909-62 2908-62
Unit: Inch (mm)Unit: Inch (mm)
Group 1 Group 2
Dial Indicator FacesOne Revolution
InchOrder No. A B C D E F G H1910-72 1.75" .42" .53" 1.52" 1.61" .59" 1.50" .28"1909-62 1.75" .42" .53" 1.52" 1.61" .59" 1.50" .28"
Metric Unit:mmOrder No. A B C D E F G H1900F-62 53.5 17 16 32.5 41 14.5 38 71929F 47.5 14 13 32.5 41 14.5 38 71929F-62 47.5 14 13 32.5 41 14.5 38 7
InchOrder No. A B C D E F G H2910-72 2.12" .44" .53" 1.84" 2.28" .69" 2.13" .35"2947F-10 2.13" .44" .59" 1.78" 2.19" .59" 2.05" .30"2909-62 2.12" .44" .53" 1.84" 2.28" .69" 2.13" .35"2976❈2 2.54" .62" .83" 1.70" 2.19" .65" 2.17" .30"2977❈2 2.56" .64" .83" 1.70" 2.19" .65" 2.17" .30"2978❈2 2.57" .65" .83" 1.70" 2.19" .65" 2.17" .30"2908-62 2.12" .44" .53" 1.84" 2.28" .69" 2.13" .35"2945-40 2.33" .66" .53" 1.96" 2.28" .69" 2.13" .35"2204F 3.05" 1.37" .59" 1.46" 2.19" .59" 2.05" .30"❈2 Flat back type only.(Lug-on-center back is not available.)
Metric Unit: mm (except 2900-73)Order No. A B C D E F G H2900-73❈1 2.13" .63" .36" 1.84" 2.28" .69" 2.13" .35"2900F 65.8 17 21 46.8 55.6 17 52 82901F 65.8 17 21 46.8 55.6 17 52 82971❈2 65.6 16.8 21 43.2 55.6 16.5 55 7.62929F 64.8 19.5 17.5 46.8 55.6 17 52 82972❈2 66 17.2 21 46.8 55.6 16.5 52 7.62973❈2 66.3 17.5 21 43.2 55.6 16.5 55 7.6❈1 Stem diameter 3/8"❈2 Flat back type only.(Lug-on-center back is not available.)
SPECIAL INDICATORS
R-78
R- 078 (2003) full size 12/9/03 1:36 PM Page 1
Back Plunger with Perpendicular Mounting StemGroup 1
SpecificationsInch–ANSI Standard (Stem Diameter 3/8")
Metric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features.001" .1" 1156 .1" 0-100 ±.001".001" .1" 950-156*1 .1" 0-100 ±.001".001" .1" 1157 .1" 0-50-0 ±.001".001" .1" 950-157*2 .1" 0-50-0 ±.001"*1) Indicator 1156 and 5 accessories.*2) Indicator 1157 and 5 accessories.
Unit: (mm)
1157
ø.375"
ø.2
50"
(ø 6
.35)
(ø9.52 )
0-0.001
0 -0.009
3.86" (98)
1.63" (41.5)
3.19" (81)
#4-48 THREADS
.87"
(22)
1.85
" (4
7)
NO.1156
. 001"
NO.1158
0.02mm
NO.1157
. 001"
010
20
30
4050
60
70
80
90 1010
2020
3030
404050
0_ + 2040
80
60
100120140
160
180
200
220240 0
NO.1159
0.02mm
20204040
8080
6060
100100120120
0_ +
1156 1157 1158 1159
Total Range DialGraduation Range Order No. Per Rev. Reading Accuracy Features0.02mm 2.6mm 1158 2.6mm 0-260 ±0.02mm0.02mm 2.6mm 1159 2.6mm 0-130-0 ±0.02mm
The measuring force for all the above indicators is 2.1N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.
AccessoriesA. 900933 Hole attachment with .157" DIA. point.B. 900934 “C” Clamp, Capacity 1.33".C. 125341 Upright rod, Length 4.52", .472" DIA.D. 125342 Square holder .472" x .472".E. 900935 Universal clamp.
SPECIAL INDICATORS
R-79
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R- 079 (2003) full size 12/9/03 1:37 PM Page 1
Back Plunger Type Dial IndicatorsGroup 1&2
Total Order Range Dial DimensionGraduation Range No. Per Rev. Reading Accuracy L Features0.001mm ±.0.05mm2990 50-0-50 ±0.0065mm 44mm0.01mm ±0.5mm 2960F 50-0-50 ±0.014mm 41.5mm0.01mm ±0.5mm 1960 50-0-50 ±0.014mm 41mm0.01mm 5mm 1160 1mm 0-100 ±0.016mm 38.5mmThe measuring force for all the above indicators is 1.4N or less, except 2990, 2991; 1.3N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.ISO/JIS type gages accuracy includes uncertainty, K=2
2991
2991 29901166 1961 1960
15
05
10
2025
30
35
40
45
0 .2
.1
N o. 116 6.001"
1515
055
1010
2020
_ +
.001"
NO. 1960
SHOCK PROOF
0 1010
2020
3030
4040
5050
0.01mm
NO. 1960S H O C K P R O O F
M A D E I N J A P A N
1160, 11661167, 1168 2960, 2961
2990, 2991
0-.001
ø1.46" (ø37)
ø1.38"(ø35)
ø.375"
(ø8 ) 0 -0.009
#4-48 Threads(M2.5x0.45)
.18"(4.5)
L1.
00"
(25.
5).9
8"(2
5)
L
ø1.38"(ø35) 0
-.001ø.375"(ø8 ) 0
-0.009
#4-48 Threads(M2.5x0.45)
.18"(4.5)
1.00
"(2
5.5)
.98"
(25)
ø2.28" (ø58)
0-.001
0 -0.009
ø.375"(ø8 )
#4-48 Threads(M2.5x0.45)
L1.
57"
(40)
ø2.28"(ø51)
1.04
"(2
6.5)
ø2.28" (ø58)
011
22
33
44
_ +
.0001"NO. 29916 J E W E L S
S H O C K P R O O F6 J E W E L S
S H O C K P R O O FM A D E I N J A P A N
0 10102020
3030
4040
50501µm
NO. 2990
SpecificationsInch–ANSI Standard (Stem Diameter 3/8")
Metric–ISO/JIS Standard (Stem Diameter 8mm)
Total Order Range Dial DimensionGraduation Range No. Per Rev. Reading Accuracy L Features.0001" ±.004" 2991 4-0-4 ±.0002" 1.57".0005" ±.02" 2961 20-0-20 ±.0005" 1.38".001" ±.02" 1961 20-0-20 ±.001" 1.38".001" .2" 1166 .05" 0-50 ±.001" 1.5".001" .2" 1168 .05" 50-0 ±.001" 1.5".001" .2" 1167 .05" 0-25-0 ±.001" 1.5"
SPECIAL INDICATORS
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-80
R- 080 (2003) full size 12/9/03 1:37 PM Page 1
HicatorSeries 524
SpecificationsHICATOR–Metric (Stem Diameter 8mm)
SpecificationsHICATOR–Inch (Stem Diameter 3/8")
Total DialGraduation Range Order No. Reading Accuracy Features0.0005mm ±0.03mm 524-500 30-0-30 ±0.5µm0.001mm ±0.05mm 524-501 50-0-50 ±1µmStandard Accessory: 540774 Spindle Lifting CableThe measuring force for all the above indicators is 1.2N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.The spindle stroke for the hicators above is: Inch model; .118", Metric model; 3mm.
Total DialGraduation Range Order No. Reading Accuracy Features.0001" ±.004" 524-606 4-0-4 ±.0001".0005" ±.02" 524-607 20-0-20 ±.0003"
HICATOR–Metric (Stem Diameter 8mm)Total Dial
Graduation Range Order No. Reading Accuracy Features0.001mm ±0.05mm 524-601 50-0-50 ±1µm0.002mm ±0.1mm 524-602 100-0-100 ±1.5µm0.01mm ±0.5mm 524-603 50-0-50 ±5µmStandard Accessory: Signal Cable 139404.The measuring force for all the above indicators is 1.2N or less.The conversion factor between Newton force and gram force is 1N=101.94gf.The spindle stroke for the hicators above is: Inch model; .118", Metric model; 3mm.
The Hicator is Mitutoyo’s ultra-sensitive dial indicator. These devices arecapable of providing measurements up to 50 millionths of an inch(.00005"). The spindle is made of highly durable stainless steel, and theseindicators feature jeweled bearings for extreme sensitivity and long life.
524-607
SPECIAL INDICATORS
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-81
R- 081 (2003) full size 12/9/03 1:38 PM Page 1
HicatorSeries 524
Metric ModelUnit: (mm)
ø.375" 0-.001
(ø8 ) 0-0.009
.75"
(19)
.35"
(9)
2.60
" (6
6)1.
54"
(39)
.62"
.79"
(15.
7)(2
0)
ø2.
39"
(60.
7)
ø2.
20"
(56)
011
22
33
44
SHOCK PROOF 6 J E W E L E S
MADE IN JAPAN
524-606
.0001"_ +
055
1010
1515
2020
SHOCK PROOF 6 J E W E L E S
MADE IN JAPAN
524-607
.0005"
_ +
524-606 524-607
524-500524-501
524-601524-602524-603
524-606524-607
(ø8 ) 0-0.009
2.60
" (6
6)1.
85"
(47)
.79"
(20)
ø2.
39"
(60.
7)
ø2.
20"
(56)
.75"
(19).35"
(9)
Dial Indicator FacesHicator
SPECIAL INDICATORS
R-82
R- 082 (2003) full size 12/9/03 1:39 PM Page 1
Hicator IISeries 524 – Dial Comparator
HICATOR-II Type
Specifications
Features• High accuracy and durability due to a high precision ball guide.• Simple zero adjustment by the lockable fine adjustment screw.• Constant measuring force over the entire range is
accomplished by the built-in compression spring.• Shockproof movement prevents transmission of impact
to the inside components.• Adjustable tolerance markers allow easy setting of limits.• Optional splash guard cover and rubber bellows protect
the Hicator-II from water & contaminants.
Standard AccessoriesUser’s manual Inspection certificate
Optional AccessoriesContact point (steel ball) 02AZA720Contact point (ruby ball) 02AZA721Spindle lifting knob 02AZA764Splash guard cover 02AZA765Rubber bellows 02AZA766Mounting holder 02AZA767Spindle lifting cable 540774
Optional contact points for Hicator-II are available byusing DiaI Indicator contact points with M2.5x0.45mmthread.
0 1020
30
40
50
1020
30
40
50
Hicator-ll
1µm
ø9.53h.79"
.56"
.48"
.33"
ø.157
Contact Point
Release hole
Tolerance markers2.48"
3.83
"
3/8"
Zero adjustment screw
1
2
(8mm)
0-.00012
cator-ll
Housing
.79"
.71"
.31"
0.00005"
.59"
Adapter Brush
Front panelColor : mancel N2.5
Color : silver
2
1
0 Code No.
524-52MitutoyLY JEWELED
Code No. 524-521 524-522 524-523 524-524Model No. HR-1 HR-1E HR-05 HR-06EGraduation 0.001mm .00005" 0.0005mm .00002”Measuring range ±0.05mm ±.002” ±0.025mm ±.001”Dial face 50-0-50 2-0-2 25-0-25 1-0-1Accuracy 1.2µm .00006” 0.6µm .000024”Hysteresis 0.5µm .000025” 0.25µm .00001”Repeatability 0.5µm .000025” 0.25µm .00001”Stem Diameter 8mm 3/8" 8mm 3/8"Spindle guide Ball guideContact point Steel ball Ruby ballMeasuring force 1N ±0.2N
The measuring force for all of the above Hicators is 1N ± 0.2N.The conversion factor between Newton force and gram force is 1N=101.94gf.
shown withoptionalsplash guardcover
524-522
SPECIAL INDICATORS
R-83
R- 083 (2003) full size 12/9/03 1:39 PM Page 1
Accessories for Dial IndicatorsANSI/AGD Type (Indicators that have 3/8" diameter,and 4-48UNF contact point)Series Range Set No. Lever Spindle Stop
Only Screw Only1 Up to .25" (5mm) 21BZA610 900527 1010472 Up to .4" (10mm) 21BZA613 21BZA612 1010472 Up to .4" (10mm) 902794 900525 1010472 .5" (12.7mm)~
1" (25.4mm) 903425 903307 1927533, 4 Up to .5" 12.7mm) 903425 903307 192753
ISO/JIS Type (Indicators that have 8mm diameter,and M2.5 x 0.45 contact point)Series Range Set No. Lever Spindle Stop
Only Screw Only1 Up to 5mm 21BZA205 900527 1011712 Up to 10mm 902100 21BZA612 1011712 Up to 10mm 902011 900525 1011712 12mm~25mm 903424 903307 1926863, 4 Up to 12.7mm 903424 903307 192686
PROTECTIVE COVERSClear plastic protective covers are available that surround and protect the indicators from oils, dust andflying particles.
Part No. Reference902065* For convex crystal (bezel Ø56mm)902066* For flat crystal (bezel Ø58mm)*10 pieces per set
COLORED CAPA variety of colored caps are available for indicators witha short stroke. White colored caps are standard.
Color For strokes For Strokesless than .4" (10mm) less than .2" (5mm)
White 115749 101125Red 128153 133062Black 128154 133060Green 128155 133065Blue 128156 133063Yellow 128157 133064
LIMIT STICKERStuck on the dial face or crystal of a dial indicator toindicate tolerance limits.Three colors - red, green, and yellow.
Description Order No.Red 136420*Green 136421*Yellow 136422**10-sticker per set.
902100
Colored Cap
LimitSticker
Lifting Lever Spindle Stop Screw
Lifting Lever
Protective Cover
ACCESSORIES/STANDS
R-84
R- 084 (2003) full size 12/9/03 1:40 PM Page 1
Backs for Dial & Digimatic Indicators
DimensionOrder No. t L Thread
Series 0 21BAA005 .07" (1.7) .25" (6.35) 1/4-20UNCSeries 1 129721 .09" (2.2) .25" (6.35) 1/4-20UNCSeries 1 136025 .09" (2.2) .25" (6.35) M6X1mmSeries 2 101168 .14" (3.5) .21" (5.35) 1/4-20UNCSeries 2 136026 .14" (3.5) .25" (6.35) M6X1mmSeries 3, 4 100838 .14" (3.5) .21" (5.35) 1/4-20UNCSeries 3, 4 136027 .14" (3.5) .21" (5.35) M6X1mm
Adjustable BackAdjustable Back
Order No. tSeries 0 191559 .04" (1)Series 1 101211 .09" (2.2)Series 1 136872 .09" (2.2)(Suffix: -60, -61, -62, -70, -72)For 1003 137906 .04" (1)Series 2 101039 .1" (2.5)Series 2 131305 .12" (3)(Suffix: -40,-50, -62, -70,-72)Series 2 192910 .05" (1.2)(2XXXFB-60)Series 3,4 100836 .12" (3)
Order No. tSeries 1 193172 .09" (2.2)Series 2 101169 .14" (3.5)Series 3, 4 100839 .14" (3.5)
Lug-on-Center Back for Inch, Metric ANSI IndicatorDimension
Order No. L t WSeries 0 190139 .49" .07" .25"Series 1 101307 .49" .09" .25"Series 2 101306 .45" .1" .25"Series 2 131306 .40" .11" .25"(Suffix: -40,-50, -51, -62, -72, -73)Series 3, 4 100797 .45" .1" .25"
Flat Back Flat Back
Lug-on-Center Back
Back with Post
Back with Post
Unit: (mm)
Lug-on-Center Back for Metric Indicator Dimension
Order No. L t WSeries 0 190561 13.5mm 1mm 5mmSeries 1 101210 13.5mm 2.2mm 5mmFor 1003 137905 12.4mm 2.2mm 5mmSeries 2 101040 12.4mm 2.5mm 5mmSeries 3, 4 100691 12.4mm 2.5mm 5mm
ACCESSORIES/STANDS
R-85
R- 085 (2003) full size 12/9/03 1:40 PM Page 1
Backs for Dial & Digimatic Indicators
Order No.Series 2 101167Series 3, 4 100837
Back with Offset Lug Back with Offset Lug
Magnetic Back Magnetic Back
Order No. ThreadSeries 2 101170 1/4-28UNFSeries 2 136023 M6X1mmSeries 3, 4 100840 1/4-28UNFSeries 3, 4 136024 M6X1mm
Back with Screw Post Back with Screw Post
Series 2 Order No.Rack Back 129902Bracket for Rack Back 901964Set Adjustable Mounting 901963
Back with Adjustable Mounting Brackets (Series 2)
Back with Adjustable Mounting Brackets(Series 2)
Order No.Series 2 900928Series 3, 4 900929
ACCESSORIES/STANDS
R-86
R- 086 (2003) full size 12/9/03 1:41 PM Page 1
Contact Points for Dial & Digimatic Indicators
4-48UNFL Order No.
3/32" 1936975/32" 1011841/4" 21AAA031*3/8" 21AAA0321/2" 1011855/8" 21AAA0333/4" 1011867/8" 21AAA0341" 10118711/4" 21AAA03511/2" 21AAA03613/4" 21AAA0372" 21AAA03821/4" 21AAA03921/2" 21AAA04023/4" 21AAA0413" 21AAA042
4-48UNFL Carbide Sapphire Ruby Plastic
.28" — — — 902018
.3" 131262 131263 131264 —
.6" 131265 131266 131267 —1" 131268 131269 131270 —
M2.5 x 0.45mmL Carbide Sapphire Ruby Steel
7.3mm 901312 — — 900030*8mm 120045 120046 120047 —15mm 120049 120050 120051 —25mm 120053 120054 120055 —*Furnished with standard metric dial indicators.
Ø.118" (Ø3mm) Ball Point Spherical Point, Carbide Tipped
Needle Point, Carbide Tipped
Ø.16" Ball Point
Shell Type Point
4-48UNFOrder No.900032
M2.5 x 0.45mmL Order No.
5mm 10138610mm 10111815mm 13739320mm 10138725mm 101388
4-48UNFD d Radius L Order No.
Ø.2" Ø.17" .2" .2" 131273Ø.27" Ø.25" .16" .4" 131274Ø.41" Ø.37" .4" .4" 131275
M2.5 x 0.45mmD d Radius L Order No.
Ø5.2mm Ø4.3mm 5mm 5mm 120058Ø7mm Ø6.5mm 7mm 10mm 120059Ø10.5mm Ø9.5mm 10mm 10mm 120060
4-48UNFD L Order No.
Ø.018" .12" 131281Ø.04" .12" 131280Ø.06" .5" 131279Ø.078" .04" 131271
M2.5 x 0.45mmD L Order No.
Ø0.45mm 2.5mm 120066Ø1mm 2.5mm 120065Ø1.5mm 13mm 120064Ø2mm 1mm 120056Ø2mm 8mm 137257*Furnished with standard Inch and Metric ANSI Dial Indicators.
Spherical Point
4-48UNFD L Radius Order No.
Ø1/2" 1/8" .28" 101205Ø3/8" 3/32" .35" 101204
M2.5 x 0.45mmD L Radius Order No.
Ø10mm 5mm 7mm 101119
Ø1.8mm Ball Point
M2.5 x 0.45mm101122
Unit : (mm)Unit : (mm)
Unit : (mm).16" Rad. (4 Rad.)
Unit : (mm)
Unit : (mm)
ACCESSORIES/STANDS
R-87
R- 87 (2003) full size 12/9/03 8: 41 PM Page 1
Contact Points for Dial & Digimatic Indicators
M2.5 x 0.45mmL Order No.
8mm 131365
M2.5 x 0.45mmD T Order No.
2mm 0.4mm 1200612mm 0.6mm 1200624mm 1mm 120063
4-48UNFD T Order No.
.08" .016" 131276
.08" .024" 131277
.16" .04" 131278
Blade Point, Carbide Tipped
90° Conical Point, Carbide Tipped
Knife Edge Point, Carbide Tipped
4-48UNF131282
M2.5 x 0.45mm120067
Ø.2" (Ø5mm) Flat Point
4-48UNFL Order No.
5/16" 1330171/2" 21AAA0433/4 21AAA0441 21AAA045
Needle Point4-48UNFL Order No.
.6" 21AAA0301" 21AAA04611/2" 21AAA0472" 21AAA048
M2.5 x 0.45mmL Order No.
15mm 10112117mm 137413
60° Conical Point
4-48UNFL Order No.
1/2" 101190
M2.5 x 0.45mmL Order No.
10mm 101120
90° Conical Point
4-48UNFL Order No.
1/4" 101191
M2.5 x 0.45mmL Order No.
5mm 101385
Flat Point4-48UNFD L Order No.Ø1/2" 3/8" 101188Ø3/8" 3/8" 101189
M2.5 x 0.45mmD L Order No.
Ø10mm 10mm 101117
Flat Point, Carbide Tipped4-48UNFD d L Order No.
Ø.2" Ø.17" .2" 131259Ø.27" Ø.25" .4" 131260Ø.41" Ø.37" .4" 131261
M2.5 x 0.45mmD d L Order No.
Ø5.2mm Ø4.3mm 5mm 120041Ø7mm Ø6.5mm 10mm 120042‚10.5mm Ø9.5mm 10mm 120043
25°
Unit : (mm)
Unit : (mm)
Unit : (mm)
Unit : (mm)
Unit : (mm) Unit : (mm)
Unit : (mm)
Unit : (mm)
4-48UNFL Order No.
.08" 131272
M2.5 x 0.45mmL Order No.
2mm 120057
4-48UNFL Order No.
.3" 131283
M2.5 x 0.45mmL Order No.
8mm 120068
ACCESSORIES/STANDS
R-88
R- 088 (2003) full size 12/9/03 1:46 PM Page 1
Contact Points for Dial & Digimatic IndicatorsExtension Rod
4-48UNFL Order No.
1/2" 1391671" 3016552" 3016574" 301659
Point Conversion
M2.5 x 0.45mmL Order No.
10mm 30361120mm 30361230mm 303613100mm 303614
Lever Point
4-48UNFORDER NO.
900393
M2.5 x 0.45mmORDER NO.
900391
Roller Point
4-48UNFORDER NO.
901991
M2.5 x 0.45mmORDER NO.
901954
Carbide Contact Point4-48 UNF
Set Order No. 21AZA035Individual No. Description
131260 Flat Point ø1/4"
131274 Spherical Point ø1/4"
131279 Needle Point ø.06" 1/2" Long
131262 Ballpoint ø.118"
131271 Needle Point ø.078" .04" Long
Contact Point4-48 UNF
Set Order No. 21AZA034Individual No. Description
101184 Shell Type Point 5/32"
101185 Shell Type Point 1/2"
101186 Shell Type Point 3/4"
101187 Shell Type Point 1"
101188 Flat Point ø1/2"
101189 Flat Point ø3/8"
101190 60° Conical Point
101191 90° Conical Point
101204 Spherical Point ø3/8"
21AAA030 Needle Point .6"
Unit : (mm)
Unit : (mm)
Unit : (mm)
ACCESSORIES/STANDS
R-89
R- 089 (2003) full size 12/9/03 1:46 PM Page 1
Repair Tool KitMITUTOYO offers a tool set designed to let you performsimple repairs to your Mitutoyo dial indicator, and a devicethat lets you reset the indicator crystals.• To free a jammed bezel; Apply Molykote with a brush (8)
around the entire groove of the bezel.• To oil a bearing: Use brush (9) to apply lubricating oil to
the pinion shaft.• To remove the long pointer: Use hand remover (15) to lift
out without damaging the bearing.• To remove the short pointer: Use nippers (13).• To adjust the bearing position: Use the bearing adjuster
(18) to force the bearing into position.• To remove the pin or drive it into position: Use the pin
remover (16) and hammer (10) on the V-groove of thespindle rest (11).
• To drive the long or short pointer into position: Use thepinion rest (19) and pin rest (12) to hold the pin and pinion, then drive with hammer (10) and punch (17) intothe center position.
Order No. 7823(1) 901171 Molykote (lubricant)(2) 901172 Lubrication oil(3) 901173 Screwdriver (Phillips)(4) 901174 Screwdriver (Phillips/flat blade)(5) 129729 Tweezers(6) 901175 Pin-vise(7) 901176 Brush(8) 901177 Brush(9) 901177 Brush(10) 901178 Hammer(11) 129730 Spindle rest(12) 129731 Pin rest(13) 901179 Nippers(14) 901180 Pliers(15) 901181 Hand remover(16) 129732 Pin remover(17) 129733 Punch(18) 129734 Bearing adjuster(19) 129735 Pinion rest(20) 129736 Reamer(21) 901182 Case
10
9
1615
20
17 18
19
3
7
5
4
8
1 2
6
14
13
211211
7823
Crystal Setter (Order No. 7000)
Used for fitting a crystal on dial indicators, dial test indica-tors and dial calipers.
Features
• Use setting pads (2) and (3) for pocket-type dial test indicator.
• Use setting pads (3) and (4) for dial test indicator, universal dial test indicator, Series 1 dial indicators, anddial calipers.
• Use setting pads (7) and (8) for Series 2 dial indicatorsand dial height gages with counter.
7000
3
7
54 81 2
6
7000
DIAL INDICATORS
R-90
R- 090 (2003) full size 12/9/03 1:47 PM Page 1
Dial Gage Stands 7003 (with Serrated Anvil) and 7102 (with Flat Anvil)
The compact and versatile Dial Gage Stands are commonly used general-purpose stands for comparisonmeasurements, 4" maximum-height capacity. They feature a wide fine-adjusting range for zero-setting gageheads.
ACCESSORIES AND PARTS
101463101462101461
7003
70037004
7008
7102
7102
Max. Height FineOrder No. Capacity Adjustment Remarks7003 4.0" .04" with Serrated Anvil (No. 101462) and Swivel
Clamp Assembly (No. 990264),Stem Clamp: .375" (9.5mm)
7004 4.0" .04" with Flat Anvil (No. 101461) and Swivel Clamp Assembly (No. 990264),Stem Clamp: .375" (9.5mm)
7102 4.0" .04" with Flat Anvil (No. 101461) and Swivel Clamp Assembly (No. 58ZAA014) Stem Clamp: .591"(15mm)
Accessories and PartsOrder No. Description Order No. Description101461 Flat Anvil 990264 Swivel Clamp Assembly. (7003, 7004)101462 Serrated Anvil 206983 Stem Collar (for 8mm stem gage)101463 Domed Anvil (20mm radius) 58ZAA014 Swivel Clamp Assembly (7102)302380 Screw for Anvil
Dial Gage Standswith Flat or Grid AnvilThese Dial Gage Stands provide an ideal work base for allAGD type indicators as well as other gages with a .375" DIA.mounting stem. Select either a flat or grid type anvil.
Max. Height FineOrder No. Capacity Adjustment Remarks7008 3.54" .039" Serrated Anvil type. Stem Clamp: .375"
Accessories and PartsOrder No. Description206983 Stem Collar for 8mm stem gage.58AAA119 Serrated Anvil073146 Flat Anvil
7008
3.93" (W) x 6.30"(D)
1.77
"
2.32
"
.55" 2.28"
Hardened Steel AnvilFlatness 1µm or less
Stem clampØ.375"
3.15"1.18"(DIA)
1.57
"8.
07"
ø 15" .00.004
Hardened Steel AnvilFlatness 1µm or less
168
.55
ø 2.28"
1.77
"6.
30"
STEM CLAMP
1.97
"1.18"(DIA)
4.33" (W) x 6.61" (D)
Hardened Steel AnvilFlatness 1µm or less
2.48
".7
1" 3.54"
3.15"
Stem clamp: .375"1.18" (DIA)
1.97
"6.
30"
1.77
"8.
07"
4.33" (W) x 6.30" (D)
Dial Gage Stands
Dial Gage Stands
Specifications
Specifications
ACCESSORIES/STANDS
R-91
R- 091 (2003) full size 12/9/03 1:47 PM Page 1
Comparator StandsSeries 215
MITUTOYO Comparator Stands are basic building-blocksfor the assembly of special-purpose, precision-measuringequipment. By mounting precision-measuring instrumentsonto the stands, it is possible to satisfy all manners ofmeasuring assignments, including comparative measure-ment.
The Comparator Stands consist of a very stable, cast-iron base and an upright column with a mounting bracketthat features fine adjustment. Standard Stands are fur-nished with tapped holes for mounting optional anvils,although the flat, accurately-ground stand surfaces aretrue measuring planes. The Comparator Stands are alsoavailable without the tapped holes.
215-407
215-407215-514215-515
12.0
0"(3
05m
m)
9.84
"(25
0mm
)2.
17"
(55m
m)
1.97
"(5
0mm
)
(ø30mm)1.18"
3.74"(95mm)
Squareness
Parallelism≤ 3µm
0.2/100
4.33"(110mm)
7.48"
.98"
(25m
m)
3.15
"(8
0mm
)
4.72"
Fine Adj.Control
(120mm)(190mm)
6.69
"max
.(1
70m
m)
ø1.97
4.53"
11.8
1"
(300
mm
)
(115mm)
(50mm)
18.2
8"(4
64m
m)
15.7
5"(4
00m
m)
3.94
"(10
0mm
)2.
56"
(65m
m)
9.45" 7.05"(179mm)
3.5"
.98"
(25m
m)
Parallelism≤ 3 µm
(90m
m)
(240mm)
(150mm)5.91"
Squareness 0.2/100
Comparator StandsSpecifications
Max. Work Anvil StemOrder No. Height Type Size Mass Remarks215-407 6.69" Serrated .375" 18.2 lbs Post Type: Straight
Fine Adjustment Length: .04"215-514 11.81" Serrated .375" 37.5 lbs Post Type: Spiral
Fine Adjustment Length: 10.2"215-515 11.81" Serrated .787" or 37.5 lbs Post Type: Spiral
.375" Fine Adjustment Length: 10.2" with Bushing
ACCESSORIES/STANDS
R-92
R- 092 (2003) full size 12/9/03 1:48 PM Page 1
Comparator StandsSeries 215
Comparator Stands
Features• Has rigid construction and fine adjustments, which
makes the Comparator Stand suitable as a gagingstand for detector heads of Mu-Checkers.
• Can mount dial indicators and Hicators.• Interchangeable anvils.• Can be used for measuring roundness and straight-
ness.• These Comparator Stands use a rigid cast-iron base
and a hardened steel anvil.
• The flatness of the anvil surface is less than.000008"/0.2µm, which is suitable for precision mea-surement with a .00005"/0.001mm-resolution Digimaticindicator or Linear Gage.
• The anvil has grooves in a grid pattern to prevent theworkpiece from sticking to it.
• One-piece bracket for high rigidity and easy paralleladjustment.
215-831
Serrated Anvil390074
Specifications
Order No. Description215-831 with Serrated Anvil (No. 390074)
Accessories and PartOrder No. Description390070 Dovetail Attachment390074 Furnished Standard Serrated Anvil990014 Bracket for 1.1" (Dia.) Stem Indicators990015 4" wide serrated anvil990018 .375" (Dia.) Steel Ball Anvil
ACCESSORIES/STANDS
R-93
R- 093 (2003) full size 12/9/03 1:49 PM Page 1
Comparator StandsSeries 215
Dial Indicator clamped directly to Comparator Stand.NOTE: It is necessary to rotate the lug back of the indi-cator to its horizontal position.
Digimatic Indicator mounted on Comparator Stand byDial Holder (990033). Dial Holder accommodates instru-ments with .375" DIA. Stems, such as: Dial & DigimaticIndicators without lug-on-center back, Gage Heads,Cartridge Heads, Electronic Comparators.
APPLICATION EXAMPLES
215-630
Order No. Description For Stand No.58AAA071 Base for 215-630 (no tapped holes) 215-63058AAA073 Base for 215-640 (no tapped holes) 215-64058ZAA010 Fixed Bracket (throat depth 2.36") 215-63058ZAA011 Fixed Bracket (throat depth 4.72") 215-640990029 Serrated Anvil (W)1.5" x (D)4" x (H)1.5" 215-63058ZAA017 Serrated Anvil (W)5.5" x (D)5.12" x (H).67" 215-640990031 Domed Anvil (spherical radius .59") 215-630 and 215-640990033 Dial Holder for .375" (DIA) Stems 215-630 and 215-640
990031
58ZAA011
990033Accessories
215-630 (215-640)
215-640Shown with IDF Indicator (543-552A). Serrated anvil(58ZAA017 ) and fixed bracket (58ZAA011 )
Comparator Stands (Series 215)Order No. Description215-630 Fine Adjustment Length: .04"215-640 Fine Adjustment Length: .079"
4.49"(6.69")
5.59"(7.87")
7.95"(12.40")
5.90"(10.82")
2.36"(4.72")
7.87
"(1
1.81
")2.
48"
(2.7
5")
2.75
"
1.18" (DIA)
ACCESSORIES/STANDS
R-94
R- 094 (2003) full size 12/9/03 1:49 PM Page 1
Precision Granite Stands (with Black Granite Bases)Series 517
517-895(Stand Only)
517-898(Stand Only)
Precision Granite Stands
Bench ComparatorsSpecifications
517-985(Stand Only)
517-987(Stand Only)
517-989(Stand Only)
517-988(Stand Only)
Specifications
Bench Comparators (with Black Granite Bases)
Column Column Throat Table TableOrder No. Base Diameter Height Clearance Flatness Thickness Weight517-890 6 x 8" 1.181" 6" 4.375" .0001" 2" 18 lbs517-891 6 x 8" 1.181" 8" 4.375" .0001" 2" 19 lbs517-892 6 x 8" 1.181" 12" 4.375" .0001" 2" 20 lbs517-893 6 x 8" 1.181" 18" 4.375" .0001" 2" 21 lbs517-895 8 x 12" 1.181" 6" 5.8" .0001" 2" 29 lbs517-896 8 x 12" 1.181" 8" 5.8" .0001" 2" 30 lbs517-897 8 x 12" 1.181" 12" 5.8" .0001" 2" 31 lbs517-898 8 x 12" 1.181" 18" 5.8" .0001" 2" 32 lbs517-899 8 x 12" 1.181" 24" 5.8" .0001" 2" 35 lbs
Column Column Throat Table TableOrder No. Base Diameter Height Clearance Flatness Thickness Weight517-984 6 x 6" 3/8" 7" 1–5" .0002" 2" 10 lbs.517-985 12" x 6" 3/8" 7" 1–5" .0002" 2" 18 lbs.517-987 8 x 12" 1-1/4" 10" 3-15/16" .0002" 2" 25 lbs.517-988 18" x 12" 1-1/4" 10" 3-15/16" .0002" 4" 85 lbs.517-989 12" x 8" 7/8" 10" 1–11" .0002" 2" 20 lbs.Custom Bench Comparator Models are also available upon request.
(Height) Fine Adjustment Knob
Holder for Lug-on-Center Back
ACCESSORIES/STANDS
R-95
R- 095 (2003) full size 12/9/03 1:50 PM Page 1
Mini-Magnetic Stands
FeaturesNo. 7022 & 7023For MITUTOYO and other test indicators. .234" Dia.rod dimension is specially selected to allow two MITU-TOYO test indicator clamps No. 900291 and No.900322. Supplied with 5/16" DIA., 11/2" long extra rodfor other clamps, and .217" DIA., 43/8" long extensionsrod No. 050066.
No. 7020 & 7021For all AGD dial indicators with Standard lug on cen-ter back) and MITUTOYO and other test indicators.One end of the rod is designed to hold the DialIndicator’s back (lug on center), and the opposite endwith .234" OD. is for No. 900291 and No. 900322 testindicator clamps. Additional rod with 5/16" and 7/32"Dia. is also supplied.
7
8
70201
12
15
16
9
2
7022
Key No. Order No. Description1 050060 Post 15/64" x 11/2"2 050061 Post 5/16" x 11/2"3 050062 Fine Adj. Screw (small)4 050063 Fine Adj. Screw (large)5 050064 Knurled Alum. Nut6 050065 Rod 5/16" and 1/4" DIA.7 059020 Spindle Clamp8 059021 Clamp Rod Assy.9 059022 Stem & Nut Assy. 702210 059023 Stem & Nut Assy. 702311 059024 Stem & Nut Assy. 702512 050066 43/8" Extension Rod13 050067 Find Adj. Clamp 7021, 702513 050068 Fine Adj. Clamp 702314 050087 Stem only 702415 050088 Base only 702216 050089 Base only 7024, 7025
133
13
7021
ACCESSORIES/STANDS
R-96
R- 096 (2003) full size 12/9/03 1:51 PM Page 1
Mini-Magnetic Stands
FeaturesNo. 7024 & 7025Most complete heavy-duty for all Dial Indicators and TestIndicators available in the market. The installed rod has.234" OD, for MITUTOYO Test Indicator’s clamp, on oneend, while the other end has a clamp for dial indicators.An additional rod is provided for greater versatility.One end has 7/32" OD. (.218"), the other with 5/16" OD.(.312"). The extra rod is for other clamps usually availablein the machine stop.
Both models come with a convenient lever to detach per-manent magnet from the surface. Vee channel on themagnet allows use on round as well as flat surfaces.No. 7020, 7021, 7024 and 7025Stands take both Dial Indicators and MITUTOYO TestIndicators, plus, most other test indicators with additionalrod supplied.
70247025
14
5
6
13
4
118
Mini-Magnetic StandsSpecifications
Order No. Note Rod Diameter7022* For Test Indicators .234", 7/32", 5/16"7023* For Test Indicators
w/Fine Adjustment .234", 7/32", 5/16"7020* For Dial & Test Indicators .234", 7/32", 5/16" and Clamp7021* For Dial & Test Indicators
w/Fine Adjustment .234", 7/32", 5/16" and Clamp7024** For Dial & Test Indicators .234", 7/32", 5/16" and Clamp7025** For Dial & Test Indicators
w/Fine Adjustment .234", 7/32", 5/16" and Clamp
*PULL: 30-35 lbs. **PULL: 60-65 lbs.
ACCESSORIES/STANDS
R-97
R- 097 (2003) full size 12/9/03 1:52 PM Page 1
Mini-Magnetic StandsSeries 984
Order No. Description Magnetic Pull7010S with 6" Rod and Universal Clamp 132 lbf
7011BN with 6" Adjustable Rod and Universal Clamp 132 lbf
Very small magnetic stands permit use of Dial Indicatorsand Test Indicators in confined areas. The stands featurefine adjustment.Stands No.’s 984-107 and 108, with rectangular bases,will accept stems of 3/8" Dia. and are furnished with asleeve for locking on stems of 8mm Dia. These standsalso have a fixture for mounting dial indicators with lug-on-center backs. On Stand No. 984-107 the vertical rodis coupled to the base through a ball-and-socket joint.
Very small magnetic stand permits use of Dial Indicatorsand Test Indicators in very confined areas. The standfeatures fine adjustment. Dovetails are accepted by thepart shown in the drawing on the left; which also lockson to rods for mounting stems of .250" DIA. The extrarod will accept mounting stems of 5/32" DIA. at one end.
Order No. Description Magnetic Pull984-107 Overall Height: 5.3" (Approx) 55 lbf984-108 Overall Height: 5.5" (Approx) 55 lbf
984-107(Stand only)
984-108(Stand only)
984-101(Stand only)
Order No. Description Magnetic Pull984-101 Overall Height: 4.8" (Approx) 55 lbf
Mini-Magnetic Stands
Magnetic Stands
Mini-Magnetic Stands
Mitutoyo Magnetic Stands, shown on these pages,accept all AGD-type Dial Indicators. Test Indicators andProbes having 3/8" DIA. shank and/or Lug Back with 1/4"DIA. mounting hole.The ON-OFF Switch offers instant mounting and dis-mounting without any adverse effect to the indicators or work surface.7011BN
(Stand only)
Specifications
Specifications
Specifications
Magnetic StandsNo. 7010SN and No. 7011BN
ACCESSORIES/STANDS
R-98
R- 098 (2003) full size 12/9/03 1:53 PM Page 1
Transfer Stands (Heavy Duty Types)Series 519
Features• Designed for comparison measurements of height
using a dial indicator or dial test indicator.• Highly rigid construction without anvil ensures high
repeatability.• Rotation range of indicator holder: ±120°
519-109E
390070Dovetail attachment used with Test Indicators
6.30"
2.32
"
16.9
"
1.18"
2.28"2.56"
3.95"
.25" .375"
Transfer StandSpecifications
Order No. Description519-109E Transfer Stand with Serrated Anvil (No. 101462)
Mass: 11.9 lbs.
AccessoriesOrder No. Description101461 Flat Anvil101462 Serrated Anvil101463 Domed Anvil302380 Anvil Screws (3 pcs)390070 Dovetail Attachment990264 Fine Feed Bracket Assembly.
ACCESSORIES/STANDS
R-99
R- 099 (2003) full size 12/9/03 1:53 PM Page 1
Flexi-Stand 7012 (Stand only)
Universal Magnetic Stand 7019 (Stand only)
Universal Magnetic Stand7019 (Stand only)Features• Accepts all AGD .375" and 8mm stems.• Accepts Dial and Test Indicators.• Overall Length: Approx. 15".• Permanent magnet with on-off switch.
Flexi-Stand7012 (Stand only)Features• Accepts all AGD .375" and 8mm stems. Must order
Collar 206983 for 8mm stem.• Accepts Dial and Test Indicators.• 360° pivot, Multi-jointed arms.• One clamping knob locks all flexible joints.• On-Off Switch for instant mounting and dismounting.
7019(Stand Only)
7019
7012(Stand Only)
OneTwistClamp
OneTwistClamp
1.89"
3.54
"
4.84"
4.74
"
.375"
180°
360°
360°
360°360°280°
320°
Universal Magnetic Stand and Flexi-StandSpecifications
Order No. Description Magnetic Pull
7019 Overall Height: 15" (Approx) 132 lbfwith COLLAR (No. 206983) for 8mm stem indicator
7012 Overall Height: 15" (Approx) 132 lbf
ACCESSORIES/STANDS
R-100
R- 100 (2003) full size 12/9/03 1:54 PM Page 1
Dial Gage Upright Stand No. 7056 Complete with Dial Indicator
Features• Compact and inexpensive gaging unit that consists of
a dial indicator and a stand.• Suitable for inspecting small parts on the shop floor.• Workstage diameter: 1.57"
7056Back View
7056Front View
Complete with an adjustable workstage made ofhighly durable Zirconia Ceramics, a material whichneeds far less care than that of traditional steeltables. This advanced upright gage also utilizes thenew Mitutoyo IDC Indicator offering multiple functionsincluding ON/OFF, Preset, ZERO/ABS, Inch/Metric.Provides SPC output for data recording and statisti-cal functions.
Features• Provide GO/NG judgement function and the indica-
tion of the judgement result.• Complete with Spindle Lifting Cable 540774• Max Workstage Height: 1.2"
547-033
2.36 (W) x 4.33 (1)
4.84
"
1.38
"
1.57"DIA.
1.57"
1.34
.71.
38
ø.59"
1.77"
4.53
3.74"2.36(W)
Dial Upright Gage
Digimatic Upright Gage
Specifications
Specifications
AB
SOLUTE
TECHNOLOGY
Digimatic Upright Gage with Absolute Encoder Technology
Measuring Order No. Range Indicator Graduation Mass7056 0–1" 2416F .001" 2.6 lbs
Measuring LCD WorkstageOrder No. Range Indicator Resolution Accuracy Mass Diameter Remarks547-033 0–.5" 543-252B .00005" ±.00015" 3.7 lbs 1.97" with SPC output
0–12.7mm 0.001mm (ceramic)547-034 0–.5" 543-272B .0005" ±.001" 3.7 lbs 1.57" with SPC output
0–12.7mm 0.01mm (Steel)Replacement battery: 541980 (1 pc.), 541980-10 (10 pcs.)For SPC output order connecting cable 905338 (1m) or 905409 (2m).
ACCESSORIES/STANDS
R-101
R- 101 (2003) full size 12/9/03 1:55 PM Page 1
Multi-StandTM
Multiple Indicator Stands
MITUTOYO Multi-Stand™ offers an inspector the convenience andflexibility to custom assemble one ormore multiple indicator stands fromout of a wide selection of precisionaccessories. In fact, Mitutoyo Multi-Stand™ is not a specific stand but acollection of accessories which canbe arranged in dozens of differentset-ups, tailor made to an inspector’sindividual needs.One of the more common uses ofthe Multi-Stand™ is for part inspec-tion at the point of machining orgrinding. With this handy, custom
designed stand an inspector canaccurately check parts in production.Moreover, the stand can utilize anumber of indicators on a singlebeam offering the capability of tak-ing varied measurements at the same time.When these accessories are com-bined with indicators offering SPCdata output, Multi-Stand™can also be a valuable early warning system for quality controlsince it can be set-up very close to the machining end of the produc-tion area.
Common AssembliesItem Order No. Description
Holder & Clamp Assembly 050591050588 2" Holder050589 3" Holder050570 Clamp
Holder & Clamp Assembly 050592050589 3" Holder050590 51/2" Holder050570 Clamp
Floating Head & Clamp 050593 050574 Floating head050570 Clamp
Bench Center Assembly 050595 050571 Holding Clamps, 2pcs.050572 Loaded Center050573 Dead Center
HOLDER &CLAMPASSEMBLY050591050592
FLOATINGHEAD &CLAMP 050593
BENCH CENTERASSEMBLY050595(Not included with V-Blocks)
MULTI-STAND
R-102
R- 102 (2003) full size 12/9/03 1:56 PM Page 1
Multi-Stand™ Multiple Indicator Stands
Individual AccessoriesItem Order No. DescriptionDial Indicator Point Attachment 050568 Carbide blade (t = 0.030")Dial Indicator Point Attachment 050569 Carbide blade (t = 0.080")Clamp Holder 050570 Complete with lock screwCenter Holding Clamp 050571 Frequently used w/Bench CentersLoaded Center 050572 RetractableDead Center 050573 StationaryFloating Head 050574 Holder can move with assemblyMain Beam 050577 12" long, self-standingMain Beam 050578 18" long, self-standingMain Beam 050579 24" long, self-standingMain Beam 050580 30" long, self-standingMain Beam 050581 36" long, self-standingMain Beam 050582 42" long, self-standingV-Block 050583 Accepts 2" DIA.V-Block 050584 Accepts 2" DIA., carbide V-slotV-Block 050586 Accepts 3" DIA., carbide V-slotIndicator Holder 050587 3/4" longIndicator Holder 050588 2" longIndicator Holder 050589 3" longIndicator Holder 050590 51/2" longV-Groove Blade 050596 120° groove, 1/32" thin
1/4"
2 1/8"
1 1/4"
3/16"
1 1/2"
3/8"
3/8"
L
120°
h
w
1 1/2"
3/4"
t
h = 5/16"w = 3/16"t = 1/32"
L
2 1/4"
t
.2"
.1" .31" .25"
(Threads 4/48") 2-5/16"
1/2"
1-1/16"
1 1/2"
1 3/4"
3/8"
1 1/2"
3/4"
60°
3/8" 3/4"
2 3/4"
2"
120°
W/CARBIDE
1 1/2"
1 1/2"
1/2" 1"
FLOATING HEAD050574
INDICATOR HOLDER050587050588050589050590 V-GROOVE BLADE
050596
MAIN BEAM050577 050580050578 050581050579 050582
DIAL INDICATORPOINT ATTACHMENT050568050569
CLAMP HOLDER050570
CENTER HOLDING050571
V-BLOCK050583050584050586
LOADED CENTER050572
DEAD CENTER050573
MULTI-STAND
R-103
R- 103 (2003) full size 12/9/03 1:57 PM Page 1
Quick-Set Gaging System
Features• Universal and modular gaging system for
shaft-type parts.• Set-up or reconfigure in less than 10 min.• Can measure multiples of all the following
part attributes:LengthDiameterOvalityRun-OutPerpendicularityParallelismTaperConcentricity
• Accepts all 8mm and .375" diameter stemindicators (Dial or Digimatic) andElectronic gages (Mu-Checkers and LinearGages).
(Not available in Canada.)
Measurement of Bearing Diameters using AbsoluteIDC Digimatic Indicators 543-252B.
Measurement of Run-Out and Diameter of Valve Seatwith Absolute Digimatic Indicators 543-252B.
Multiple Diameter Measurement of pinion shaft.
QUICK SET SYSTEM
R-104
R- 104 (2003) full size 12/9/03 1:57 PM Page 1
ACCESSORIES/STANDS
R-105
Dial/Digimatic Indicator and Stand Sets
Set No.950-723
Set No.950-707
Set No.950-705
Set No.950-728
Indicator/Stand SetsSpecifications
Indicator IDS(543-683B) IDC(543-252B) 2804F-10 2915F-10 2416FStand Digimatic Indicator Digimatic Indicator Dial Indicator Dial Indicator Dial Indicator
7010SNMagnetic Stand Set No. 950-720 Set No. 950-721 Set No. 7045 Set No. 950-700 Set No. 7046
7011BNMagnetic Stand Set No. 950-722 Set No. 950-723 Set No. 950-702 Set No. 950-703 Set No. 950-701
7012Magnetic Flexi-Stand Set No. 950-724 Set No. 950-725 Set No. 950-705 Set No. 950-706 Set No. 950-704
7019Universal Stand Set No. 950-726 Set No. 950-727 Set No. 950-708 Set No. 950-709 Set No. 950-707
7003Serrated Anvil Stand Set No. 950-728 Set No. 950-729 Set No. 950-711 Set No. 950-712 Set No. 950-710
7004Flat Anvil Stand Set No. 950-730 Set No. 950-731 Set No. 950-714 Set No. 950-715 Set No. 950-713
R- 105 (2003) full size 12/9/03 1:58 PM Page 1
THICKNESS GAGES
R-106
Quick MiniSeries 7
700-122
700-118
700-118
It's the size of abusiness card, butwith the power and
precision ofMitutoyo inside.
Quick Mini is a convenient snap-action pocket thicknessgage offering LCD digital readout. Quick Mini is ideal forrapid checking of a wide variety of materials includingmetal, paper, plastics and wood.
SpecificationsQuick Mini
Inch/MetricOrder No. 700-118 700-122Measuring Range .5"/12mm 1"/25mmResolution .0005"/0.01mmInstrumental Error ±.001"/±0.02mmRepeatability .0005"/0.01mmBattery SR44 #541980
Battery Life: 2 years under normal useMax. Response Speed 1,600 mm/sAlarm Battery voltage low, overspeed
Note: SPC output is not provided on Quick Mini
700-122
R- 106 (2003) full size 12/9/03 1:59 PM Page 1
Flat Anvil Type
IDS Types (Digital Reading) IDC Types (Digital Reading) Dial Indicator Types (Analog Reading)• ON/OFF • ON/OFF • ANSI Group 2 Dial Indicator• Inch/mm Conversion • Inch/mm Conversion• Origin • Zero/ABS• ±Direction Changeover • ±Direction Changeover• SPC Output • SPC Output• Battery Life: 20,000 hrs • Battery Life: 5,000 hrs• Power Supply: Silver Oxide Cell • Power Supply: Silver Oxide Cell
(SR-44 1pc.) (SR-44) 1pc.)• Indicator Used: 543-683B • Preset
or 543-693B • Provides GO/±NG Judgement• Face Rotates 330°• Indicator Used: 543-272B
or 543-252B
547-300 (IDC TYPE)
547-400 (IDC TYPE)(High Resolution)
7326 (DIAL TYPE)(High Resolution)
547-526 (IDS TYPE)(High Resolution)
7390FR (FRACTION TYPE)
547-520 (IDS TYPE)(Deep Throat Type)
Features
THICKNESS GAGES
R-107
R- 107 (2003) full size 12/9/03 2:00 PM Page 1
547-500, 547-526, 547-300,7300, 7304, 7326, 7390FR7301, 7305
dimensions: in (mm)*547-400 has ø0.25"(6.35mm)‡547-400 has a .8" throat depth
547-520, 547-320, 73227321, 7323
dimensions: in (mm)
Inch/MetricOrder No. Resolution Range Type Accuracy Measuring Force Indicator547-500* .0005"/0.01mm 0–.47"/0–12mm ø.4" Flat ±.001" less than 1.5N Digimatic IDS547-520* .0005"/0.01mm 0–.47"/0–12mm ø.4" Flat ±.001" less than 1.5N Digimatic IDS547-526 .0001"/0.001mm 0–.47"/0–12mm ø.4" Flat ±.0002" less than 1.5N Digimatic IDS547-300* .0005"/0.01mm 0–.4"/0–10mm ø.4" Flat ±.001" less than 1.5N Digimatic IDC547-320* .0005"/0.01mm 0–.4"/0–10mm ø.4" Flat ±.001" less than 1.5N Digimatic IDC547-400*1 .00005"/0.001mm 0–.47"/0–12mm ø.25" Flat ±.0015" less than 3.5N Digimatic IDC7300 .001" 0–.4" ø.4" Flat ±.001" less than 1.5N Dial Indicator7304 .001" 0–1.0" ø.4" Flat ±.002" less than 1.5N Dial Indicator7322 .001" 0–1.0" ø.4" Flat ±.002" less than 1.5N Dial Indicator7326 .0001" 0–.05" ø.4" Flat ±.0002" less than 1.5N Dial Indicator7390FR 1/64" 0–1.0" ø.4" Flat ±.0052" less than 1.5N Dial IndicatorSPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
MetricOrder No. Resolution Range Type Accuracy Measuring Force Indicator7301* 0.01mm 0–10mm ø.4" Flat ±0.015mm less than 1.4N Dial Indicator7321* 0.01mm 0–10mm ø.4" Flat ±0.015mm less than 1.4N Dial Indicator7305* 0.01mm 0–20mm ø.4" Flat ±0.025mm less than 2.0N Dial Indicator7323* 0.01mm 0–20mm ø.4" Flat ±0.025mm less than 2.0N Dial Indicator* Contacts are CERA (Ceramic)*1 Contacts are Carbide
THICKNESS GAGES
R-108
R- 108 (2003) full size 12/9/03 2:01 PM Page 1
7313547-312
Reverse Anvil
Pipe Measuring Type
547-3617360
dimensions: in (mm)
dimensions: in (mm)
MetricOrder No. Resolution Range Accuracy Measuring Force Indicator547-313 .0.01mm 0–10mm ±0.020mm less than 1.5N Digimatic IDC7313 .0.01mm 0–10mm ±0.015mm less than 1.4N Dial Indicator
Dial Thickness Gages
Inch/MetricOrder No. Resolution Range Accuracy Measuring Force Indicator547-512 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDS547-513 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDC7312 .001" 0–.4" ±.001" less than 1.5N Dial IndicatorSPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
Inch/MetricOrder No. Resolution Range Accuracy Measuring Force Indicator547-561 .0005"/0.01mm 0–.47"/0–10mm ±.001" less than 1.5N Digimatic IDS547-361 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDC7361 .001" 0–.4" ±.001" less than 1.5N Dial IndicatorSPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
THICKNESS GAGES
R-109
MetricOrder No. Resolution Range Accuracy Measuring Force Indicator547-360 .0.01mm 0–10mm ±0.020mm less than 1.5N Digimatic IDC7360 .0.01mm 0–10mm ±0.015mm less than 1.4N Dial Indicator
R- 109 (2003) full size 12/17/03 9: 17 AM Page 1
7315
547-528
547-316 (IDC Type)
Blade Anvil Type
Universal Type(Interchangeable Anvils)
dimensions: in (mm)
Recommended Combinations
(Points Included)
MetricOrder No. Resolution Range Accuracy Measuring Force Indicator7315 .0.01mm 0–10mm ±0.015mm less than 1.4N Dial Indicator
Dial Thickness Gages
B
A
C
A
E
A
B
D
E
D
C
F
C
D
B
F
.94"
(23.
8)
.94"
(23.
8)
.91"
(23.
1)
1.00
"(2
5.4)
.98"
(24.
8)
1.00
"(2
5.4)
1.00
"(2
5.4)
1.00
"(2
5.4)
Inch/MetricOrder No. Resolution Range Accuracy Measuring Force Indicator547-516 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDS547-316 .0005"/0.01mm 0–.4"/0–10mm ±.001" less than 1.5N Digimatic IDC7316 .001" 0–.4" ±.001" less than 1.5N Dial IndicatorSPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
Inch/MetricOrder No. Resolution Range Accuracy Measuring Force Indicator547-528 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDS7328 .001" 0–.4" ±.001" less than 1.5N Dial IndicatorSPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
A. 133017 Flat Point ø.20B. 21AAA033 Shell Point .16" RadiusC. 21BZA767 Spherical Point .36" RadiusD. 101188 Flat Point ø.50"E. 21AAA030 Needle Point .016" RadiusF. 21AAA032 shell Point .16" Radius
THICKNESS GAGES
R-110
R- 110 (2003) full size 12/17/03 9: 19 AM Page 1
Digi-Test Digimatic Caliper GagesSeries 209
Versatile I.D. measuring gage for hole diameters, inter-nal grooves, and other hard-to-reach inside diameters.
Features• Inch/mm conversion• Sound signal when measurement result is determined• AUTO-Power off• 0-pre-selection• SPC output• Display: 7-segment-LCD, digit height .28"(7mm)• Measuring force: 0.9–1.5N• Battery: LITHIUM 3V (CR-123A, DL-123A)
Part No. 64PPP477
• Measuring program (MODES)MODE 1. Continuous display of measured valuesMODE 2. Minimum holdMODE 3. Maximum holdMODE 4. Statistical program (2 SEC)
2-point measuring contactCarbide ball diameter:see table below
209-633
(Not available in Canada.)
SpecificationsDigi-Test Digimatic Caliper GagesInch/MetricOrder No. Measuring Resolution Accuracy Max. Measuring Max. Groove Min. Groove Carbide Weight
Range Depth L Depth A Width B Ball Dia. Ib. (g)209-632 .197–.6888" .0002" ±.0008" .79" .09" .04" .03" .75
5–17.5mm 0.005mm ±0.02mm 20mm 2.3mm 1.0mm 0.8mm (340)209-633 .394–1.3775" .0005" ±.001" 3.23" .20" .04" .04" .77
10–35mm 0.01mm ±0.03mm 82mm 5.0mm 1.1mm 1.0mm (350)209-634 1.1815–2.165" .0005" ±.001" 3.23" .26" .05" .04" .77
30–55mm 0.01mm ±0.03mm 82mm 6.5mm 1.2mm 1.0mm (350)209-635 1.969–2.9525" .0005" ±.001 3.23" .39" .04" .04" .79
50–75mm 0.01mm ±0.03mm 82mm 10.0mm 1.1mm 1.0mm (360)209-636 2.756–3.740" .0005" ±.001" 3.23" .39" .04" .04" .79
70–95mm 0.01mm ±0.03mm 82mm 10.0mm 1.1mm 1.0mm (360)209-637 .591–2.559" .001" ±.002" 7.09" .20" .06" .06" .97
15–65mm 0.02mm ±0.04mm 180mm 5.0mm 1.5mm 1.5mm (440)209-638 1.575–3.543" .001" ±.002" 7.09" .39" .08" .08" .97
40–90mm 0.02mm ±0.04mm 180mm 10.0mm 2.1mm 2.0mm (440)209-639 2.756–4.724" .001" ±.002" 7.09" .39" .08" .08" .97
70–120mm 0.02mm ±0.04mm 180mm 10.0mm 2.1mm 2.0mm (440)For SPC output order connecting cable 011055 (2m).
CALIPER GAGES
R-111
R- 111 (2003) full size 12/9/03 2:03 PM Page 1
Digi-Test Digimatic Caliper GagesSeries 209
Versatile O.D. measuring gage for grooves and otherhard-to-reach outside dimensions.
Features• mm/inch conversion• Sound signal when measurement result is determined• Auto-Power off• 0-pre-selection* SPC output* Display: 7-segment-LCD, digit height .28" (mm)• Measuring force: 0.9 – 1.5N• Battery: LITHIUM 3V (CR-123A, DL-123A)
Part No. 64PPP477
Measuring program (MODES)MODE 1. Continuous display of measured valuesMODE 2. Minimum holdMODE 3. Maximum holdMODE 4. Statistical program (2 SEC)
Measuring contact forwall thickness and thicknessCarbide ball. dia. 1.5 mm(dia. 2mm) *
Measuring contact for outside groovesand round materialKnife-edge R 0.5mm(R 0.74mm) *
Measuring contact for pipe wall thicknessOpening dia. from3.5mm (9.5mm),Carbide ball. dia. 1.5mm(dia. 2mm) *
Measuring contact for flat surfacesand soft materialsdisc dia. 10mm(dia. 50mm) *
* Data in brackets ( ) for measuring range 0.5–50mm
209-837
A B C D
(Not available in Canada.)
SpecificationsDigi-Test Digimatic Caliper GagesInch/MetricOrder No. Measuring Resolution Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth L Depth A Width B Contacts Ib. (g)209-868 .0078"–.492" .0002" ±.0008" 1.02" –– –– C .75
0.2–12.5mm 0.005mm ±0.015mm 26mm (340)209-837 .012"–.984" .0005" ±.001" 3.31" .87" .06" A .79
0.3–25mm 0.01mm ±0.02mm 84mm 22mm 1.5mm (360)209-838 .012"–.984" .0005" ±.001" 3.31" .87" .06" B .79
0.3–25mm 0.01mm ±0.02mm 84mm 22mm 1.5mm (360)209-839* .012–.984" .0005" ±.001" 3.37" –– –– D .79
0.3–25mm 0.01mm 0.03mm 85.5mm (360)209-640 .020"–1.969" .001" ±.002 6.69" 1.26" .08" A .97
0.5–50mm 0.02mm ±0.04mm 170mm 32mm 2.1mm (440)209-641 .020–1.968" .001" ±.002" 6.69" 1.26" .08" B .97
0.5–50mm 0.02mm ±0.04mm 170mm 32mm 2.1mm (440)209-642* .020–1.968" .001" ±.002" 6.69" –– –– D .97
0.5–50mm 0.02mm ±0.06mm 170mm (440)209-643 .020–1.968" .001" ±.002" 6.69" –– –– C .97
0.5–50mm 0.02mm ±0.04mm 170mm (440)*Mode function 2,3 does not work. For SPC output order connecting cable 011055 (2m).
CALIPER GAGES
R-112
R- 112 (2003) full size 12/9/03 2:03 PM Page 1
Dial Caliper Gages External TypeSeries 209
Features• Versatile O.D. measuring gage for grooves and other
hard-to-reach outside dimensions.
209-794
209-783
(Not available in Canada.)
CALIPER GAGES
R-113
SpecificationsDial Caliper Gages External TypeInchOrder No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth Depth Width Contact Ib. (g)209-791 0–.2" .0002" ±.0008" 1.07" .31" .09" K/K .26 (120)209-792 0–.2" .0002" ±.001" 1.07" .33" .04" T .26 (120)209-793 0–.4" .0005" ±.0008" 2.38" .32" .09" K/K .31 (140)209-794 0–.4" .0005" ±.0008" 2.38" .35" .09" RK/K .31 (140)209-795 0–.4" .0005" ±.0008" 2.38" .32" .05" S .31 (140)209-796 0–.4" .0005" ±.001" 2.38" .35" .05" RS .31 (140)209-784 0–1.0" .0005" ±.0015" 3.2" .87" .14" K/K .44 (200)209-785 0–1.0" .0005" ±.0015" 3.2" .87" .14" RK/K .44 (200)209-786 0–1.0" .0005" ±.0015" 3.2" .87" .14" RS .44 (200)209-787 0–1.0" .0005" ±.0015" 3.2" .87" .14" S .44 (200)209-782 0–2.0" .001" ±.002" 6.8" 1.26" .18" K/K .64 (290)209-783 0–2.0" .001" ±.002" 6.8" 1.26" .18" RK/K .64 (290)209-788 2.0–4.0" .001" ±.003" 6.8" 1.26" .18" K/K .68 (310)209-789 0–.5" .005" ±.005" 1.38" –– –– PK .09 (40)209-790 0–.5" .005" ±.005" 1.32" –– –– PR .09 (40)
MetricOrder No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth Depth Width Contact Ib. (g)209-658 0–5mm 0.005mm ±0.015mm 26mm –– –– T .26 (120)209-660 0-10mm 0.01mm ±0.02mm 59mm 5.0mm 3.0mm S .31 (140)209-659 0–10mm 0.01mm ±0.02mm 59mm 5.0mm 3.0mm K/K .31 (140)209-662 0–10mm 0.01mm ±0.02mm 59mm 4.8mm 2.0mm R/S .31 (140)209-661 0–10mm 0.01mm ±0.02mm 59mm 4.8mm 2.0mm RK/K .31 (140)209-840 0–20mm 0.01mm ±0.025mm 56mm 7mm 3.0mm S .46 (210)209-605 0–20mm 0.01mm ±0.03mm 85.5mm 20mm 3.5mm S .44 (200)209-601 0–20mm 0.01mm ±0.03mm 85.5mm 20mm 3.5mm K/K .44 (200)209-606 0–20mm 0.01mm ±0.03mm 82.5mm 20mm 3.5mm RS .44 (200)209-607 0–20mm 0.01mm ±0.03mm 82.5mm 20mm 3.5mm RK/K .44 (200)209-843 0–10mm 0.1mm ±0.1mm 35mm –– –– PK .09 (40)209-603 0–10mm 0.1mm ±0.1mm 33.5mm –– __ PR .09 (40)209-602 0–50mm 0.05mm ±0.05mm 173mm 30mm 4.5mm K/K .64 (290)209-604 0–50mm 0.05mm ±0.05mm 173mm 30mm 4.5mm R .68 (310)
R- 113 (2003) full size 12/9/03 2:04 PM Page 1
Dial Caliper Gages External TypeSeries 209
Measuring contact types
S
PK PR
(Not available in Canada.)
RS
R
K/K
RK/K
T
CALIPER GAGES
R-114
R- 114 (2003) full size 12/9/03 2:04 PM Page 1
Dial Caliper Gages Internal TypeSeries 209
Features• Versatile I.D. measuring gage for hole diameters, inter-
nal grooves, and other hard-to-reach inside dimen-sions.
209-735
209-735
209-894
209-715
209-730
(Not available in Canada.)
����������������
yyyyyyyyyyyyyyyy
������������
yyyyyyyyyyyy
110
- 0.
200
100
- 0.
200
90 -
0.2
00
80 -
0.2
00
70 -
0.2
00
60 -
0.2
00
4.4" 3.
9" 3.4"
2.9"
2.4"
3.1"
209-715
209-894
CALIPER GAGES
R-115
R- 115 (2003) full size 12/9/03 2:05 PM Page 1
Dial Caliper Gages Internal TypeSeries 209
Carbide ball dia. .04"(1mm) Carbide ball dia. .024"(0.6mm) Radius .004"(0.6mm)
(Not available in Canada.)
A B C
SpecificationsDial Caliper Gages Internal TypeInchOrder No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth L Depth A Width B Contacts Ib. (g)209-730 .10–.30" .0002" ±.0008" 1.07" .036" .016" C .26 (120)209-731 .20–.40" .0002" ±.0008" 1.07" .087" .047" B .26 (120)209-732 .20–.60" .0005" ±.001" 2.39" .094" .030" B .31 (140)209-733 .40–.80" .0005" ±.001" 2.39" .210" .050" A .31 (140)209-712 .40–1.4" .0005" ±.0015" 3.10" .200" .043" A .44 (200)209-734 .80–1.2" .0005" ±.001" 2.38" .210" .050" A .31 (140)209-713 1.0–2.0" .0005" ±.0015" 3.10" .200" .047" A .44 (200)209-735 1.2–1.6" .0005" ±.001" 2.38" .210" .050" A .31 (140)209-736 1.6–2.0 .0005" ±.001" 2.38" .210" .050" A .31 (140)209-760 1.6–2.6" .0005" ±.0015" 3.10" .350" .047" A .44 (200)209-761 2.2–3.2" .0005" ±.0015" 3.10" .350" .047" A .44 (200)209-762 2.8–3.8" .0005" ±.0015" 3.10" .350" .047" A .44 (200)209-763 3.2–4.2" .0005" ±.0015" 3.10" .350" .047" A .44 (200)209-715* 2.4–5.4" .0005" ±.0015" 3.10" –– –– A .44 (200)209-716* 4.7–7.7" .0005" ±.0015" 3.10" –– –– A .44 (200)*Interchangeable contact points (additional anvil 4 pcs.) with ball point .04" dia.
MetricOrder No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth L Depth A Width B Contacts Ib. (g)209-650 2.5–7.5mm 0.01mm ±0.015mm 10mm 0.7mm 0.6mm C .26 (120)209-651 5–10mm 0.01mm ±0.015mm 22mm 2.2mm 1.4mm B .26 (120)209-652 5–15mm 0.01mm ±0.02mm 30mm 1.7mm 1.1mm C .31 (140)209-653 10–20mm 0.01mm ±0.02mm 50mm 4.0mm 2.0mm D .31 (140)209-608 10–30mm 0.01mm ±0.03mm 80mm 4.5mm 1.2mm A .44 (200)209-654 20–30mm 0.01mm ±0.02mm 52mm 4.0mm 2.0mm D .31 (140)209-609 20–40mm 0.01mm ±0.03mm 80mm 6.0mm 1.2mm A .44 (200)209-655 30–40mm 0.01mm ±0.02mm 57mm 4.5mm 2.0mm A .31 (140)209-600 30–50mm 0.01mm ±0.03mm 80mm 6.0mm 1.2mm A .44 (200)209-656 40–50mm 0.01mm ±0.02mm 57mm 4.5mm 2.0mm A .31 (140)209-884 40–60mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)209-885 50–70mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)209-886 60–80mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)209-887 70–90mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)209-888 80–100mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)209-894* 60–130mm 0.01mm ±0.03mm 80mm –– –– A .44 (200)*Interchangeable contact point (additional anvil 5pcs.) with ball point 1mm dia
CALIPER GAGES
R-116
R- 116 (2003) full size 12/9/03 2:05 PM Page 1
Dial Caliper Gages Internal TypeSeries 209
The internal Dial Caliper Gages are highly recommendedfor quick ID comparison, and are the only handy gage toreach 3.25"and still measure recesses for “O” ring etc.The caliper is spring loaded and makes point contact at constant measuring pressure.The Dial Caliper Gage is used only as a comparisongage, and should be used along with a master ring or a micrometer.The moveable bezel/graduation plate must be adjustedbefore gaging by bringing the zero point to a known size.
Features• Black-oxide-finish caliper arms have .04" DIA. steel ball
on the measuring tips.• Chrome-plated housing and bezel.• With revolution counter.• Choice of inch or metric models.• Measures hard-to-get-at IDs.• Supplied with fitted carrying case.
SpecificationsDial Caliper GagesInch
DimensionsOrder No. Range Graduation Accuracy A B C D209-111 .4"–1.4" .001" ±.002" .189" .090" .189" .090"209-113 1.2"–2.2" .001" ±.002" .268" .169" .669" .571"209-115 2.0"–3.0" .001" ±.002" .386" .299" .453" .386"
MetricDimensions
Order No. Range Graduation Accuracy A B C D209-101 10–35mm 0.025mm ±0.04mm 4.8mm 2.3mm 4.8mm 2.3mm209-103 30–55mm 0.025mm ±0.04mm 6.8mm 4.3mm 17.0mm 14.5mm209-105 50–75mm 0.025mm ±0.04mm 10.0mm 7.6mm 11.5mm 9.8mm
209-115
209-101
.04" DIA.steel ball
209-101209-111
.09"
THICKNESS GAGES
R-117
R- 117 (2003) full size 12/9/03 2:06 PM Page 1
Dial Tension GagesSeries 546Features• Can measure dynamic tension in Newton (N) units.• Dial Tension Gages are widely used to determine the
contact force of other measuring instruments as wellas that of electrical relays, micro-switches, valves andprecision springs.
• Convenient peak-hold type gages are also available.
Order No. MinimumStandard Peak-hold Range Reading546-112 – 6-50 mN 2 mN546-113 546-133 10-100 mN 5 mN546-114 546-134 30-300 mN 10 mN546-115 546-135 0.06-0.5 mN 0.02 N546-116 546-136 0.1-1 N 0.05 N546-117 546-137 0.15-1.5 N 0.05 N546-118 546-138 0.3-3 N 0.1 N546-119 546-139 0.6-5 N 0.2 N
Note: Dimensions shown inbold face are for models546-112 and 546-113only.
Pocket Thickness GagesSeries 7These very compact thickness gages are designed forcarrying convenience and are ideally suited for quickinspection of paper, leather, wire, plastic, sheet metaland similar materials. The spindle is pre-loaded to pro-vide a constant measuring force.
Features• Measuring faces are hardened, ground and lapped for
accuracy.• Parallelism: .0002" or less.
7309Metric
7308Inch
546-112
546-137
SpecificationsPocket Thickness GagesInch
MeasuringOrder No. Range Resolution Accuracy Force Range/Rev Mass7308 0–.4" .001" ±.001" 0.2N or less .1" .19lbs
MetricMeasuring
Order No. Range Resolution Accuracy Force Range/Rev Mass7309 0–10mm 0.01mm ±0.015mm 0.2N or less 1.0mm .19lbs
THICKNESS GAGES
R-118
R- 118 (2003) full size 12/9/03 2:06 PM Page 1
Snap GagesSeries 201
FeaturesThese versatile, spring-loaded gages can perform awide variety of precision measuring jobs with speed andefficiency. They can be equipped with many different dialor Digimatic indicators.Additionally, when Digimatic indicators are used, dataoutput is available for SPC analysis.
Options• Must select measuring indicator• Stand Order No. 64AAA200• SPC output connecting cable
Oder No. 905338 (40"/1m)905409 (80"/2m)
201-803201-807with Dial Indicator(2803B-10)
ABCD
SLIM HANDLE TYPE ANATOMIC HANDLE TYPE
201-806with IDC(543-252B)
B
210-801, 201-802, 201-803
D
AC
MIN.
MAX.
B
210-806, 201-807
D
AC
SpecificationsSnap GagesOrder No. 201-801 201-802 201-803 201-806 201-807Retooling Range .12-.20"/3-5mm .20-.39"/5-10mm .39-.98"/10-25mm .98-1.97"/25-50mm 1.97-3.94"/50-100mmContact Measuring ±.0118"/0.3mm ±.0157"/0.4mm ±.0197"/0.5mmRangeMechanical Repeatability ≤ .00004"/ ≤ 0.001mm(σ x 2.77)Force of the pushing 5–8NDeviceMass (without Measuring .750-.926 lb 1.410-1.929 lb 1.874-2.392 lbInstrument) 0.34-.0.42 kg 0.64-0.88 kg 0.85-1.09 kgFlatness of Reference .0004"/0.01mmAnvilFixing Diameter of 3/8"Measuring InstrumentDimension 2.83" (72mm) 5.55" (141mm) 6.89" (175mm)
4.02" (102mm) 6.22" (158mm) 7.83" (199mm).87" (22mm) 1.57" (40mm)
.79" (20mm)
SNAP GAGES
R-119
R- 119 (2003) full size 12/9/03 2:07 PM Page 1
Snap GagesSeries 201
Features• Designed for quick inspection of diameters of cylinders
and shafts in machining processes.• Wide (.53"x.47"), flat carbide anvils.• Both front edges of the anvil are chamfered for
easy insertion.• Accepts all Dial Indicators and Electronic Gages with
.375" diameter mounting stem.• Anvil movement .080"• Accuracy
Parallelism .0002"Flatness .00004"Repeatability .0001"
201-151with Indicator2803FB-10
SpecificationsSnap Gages (Without Dial Indicator)Inch
Measuring Dimension DimensionOrder No. Range Force A B201-151 0–1" 15±3N .55" 1.69"201-152 1–2" 15±3N .86" 2.63"201-153 2–3" 15±3N 1.45" 3.66"201-154 3–4" 15±3N 2.00" 4.64"201-155 4–5" 15±3N 2.63" 5.67"201-156 5–6" 15±3N 3.15" 6.65"201-157 6–7" 15±3N 3.66" 7.67"201-158 7–8" 15±3N 3.93" 8.66"201-159 8–9" 15±3N 4.37" 9.72"201-160 9–10" 15±3N 4.92" 10.59"201-161 10–11" 15±3N 5.51" 11.53"201-162 11–12" 15±3N 6.02" 12.63"
0 1122
334455
6677
8899 10
1µm
0
. 2. 4. 6
. 8
1.0
SHOCK P ROOF6 J E W E L S
_ +
2109F-11
SNAP GAGES
R-120
R- 120 (2003) full size 12/15/03 1: 17 PM Page 1
TruetestTM Test IndicatorsSeries 513
FeaturesMitutoyo introduces three new Series 513 dial indicators,each available in white, black or blue dial face colors.Each indicator features:• Smooth spindle movement for increased measuring
accuracy.• Water and dust resistant one-piece black bezel and
hard coated crystal for improved durability
• 20° tilted dial face for easy reading• Anti-magnetic characteristics.
SpecificationsTruetestTM Test IndicatorsInch
Range Per Dial Order No. Wide Range DimensionGraduation Revolution Range Reading Basic Complete Accuracy L Remarks
513-443White Face 513-443-06
Black Face
Dimensions
For ø5/32" and ø3/8" stems
Swivel Clamp 900322
White DialFaceBlue DialFaceBlack Dial FaceWhite FaceLong-pointBlack FaceLong-pointWhite DialFaceBlack DialFace
.78"
1.33"
.59"
±.0005"
±.0005"
±.0002"
513-442T
513-442T-01
513-442T-06
513-446T
513-446T-06
513-443T
513-443T-06
513-442
513-442-01
513-442-06
513-446
513-446-06
513-443
513-443-06
.06"
.06"
.016"
0-15-0
0-15-0
0-4-0
.0005"
.0005"
.0001"
.03"
.03"
.008"
Nut190322
ø5/32" stem190318
ø3/8" stem190321
ø.118" contact point
ø.039" contact point
CompleteBasic
Indicator with a ø.078" carbidecontact point
Square arm900306
TEST INDICATORS
R-121
R- 121 (2003) full size 12/9/03 2:08 PM Page 1
1
2 3 45
6
6
6
Structure1 “O” ring incorporated in new bezel design seals
instrument from dust and oil mist.2 Enlarged pitch of teeth on crown gear improves abili-
ty of indicator to withstand shock.3 Rubber bumpers limit travel of sector gear and pre-
vent damage due to excessive travel.4 Special alloy of sector gear provides greater resis-
tance to wear, and longer distance between pivotpoints of linkage to better protect against shock.
5 Carbide point, .078" DIA., is standard.6 Dovetails, integral with housing, give broad flexibility
for mounting of instruments.
The most direct gear train design ever applied to TestIndicators means—higher level of sensitivity, reliability,repeatability and accuracy throughout tool life.
Vertical Type(Inch)
Inch/Metric"Combitest" 513-453
513-406
513-412
Specifications“Quick-Set” Test IndicatorsInch/Metric
Dial Order No.Graduation Range reading Basic Complete Accuracy Type Remarks.0005" .03" 0-15-0 513-406 513-406T ±.0005" Horizontal Combitest0.01mm 0.7mm 0-35-0 Anti-Magnetic
InchDial Order No.
Graduation Range reading Basic Complete Accuracy Type Remarks.0001" .008" 0-4-0 513-403 513-403T ±.0001" Horizontal.0001" .008" 0-4-0 513-453 513-453T ±.0001" Vertical.0001" .008" 0-4-0 513-463 — ±.0001" Horizontal Mini-Dial.0005" .03" 0-15-0 513-402 513-402T ±.0005" Horizontal.0005" .03" 0-15-0 513-452 513-452T ±.0005" Vertical.0005" .03" 0-15-0 513-462 — ±.0005" Horizontal Mini-Dial.0005" .03" 0-15-0 513-282* 513-982* ±.0005" Parallel.0005" .03" 0-15-0 513-412 513-412T ±.0005" Horizontal Long Point
*513-282 and 513-982 are not anti-magnetic.
"Quick-Set" Test Indicators Series 513
MetricDial Order No. Measuring
Graduation Range Reading Basic Complete Accuracy Force Remarks0.002mm 0.2mm 0-100-0 513-405E 513-405T 0.003mm 0.3N or Less Horizontal0.002mm 0.2mm 0-100-0 — 513-455T 0.003mm 0.3N or Less Vertical0.01mm 0.5mm 0-25-0 513-414E 513-414T 0.01mm 0.2N or Less Horizontal 0.01mm 0.8mm 0-40-0 513-404E 513-404T 0.008mm 0.3N or Less Horizontal0.01mm 0.8mm 0-40-0 — 513-454T 0.008mm 0.3N or Less Vertical0.01mm 1.0mm 0-50-0 513-415E 513-415T 0.01mm 0.2N or Less Horizontal
Features• Anti-magnetic*• Jeweled bearings• No-clutch structure• Water and dust resistant• Glare-free crystal with scratch-resistant coating• Metric dial faces in yellow
TEST INDICATORS
R-122
R- 122 (2003) full size 12/9/03 2:09 PM Page 1
"Quick-Set" Indicator Dimensions
Parallel Type
Vertical Type
Universal Type
Horizontal Type
Horizontal TypeDimensions Unit: inchOrder Number A B C D E F G H513-463 .98" .67" .61" 1.10" 1.61" 1.46" .59" .32"513-462 1.00" .65" .61" 1.00" 1.96" 1.81" .78" .32"513-403, 513-403T .98" .67" .61" 1.54" 1.61" 1.46" .59" .32"513-405E, 513-405T513-402, 513-402T513-404E, 513-404T .98" .67" .61" 1.54" 1.61" 1.46" .78" .32"513-406, 513-406T513-412, 513-412T .98" .67" .61" 1.54" 1.61" 1.46" 1.33" .32"513-414E, 513-414T .98" .67" .61" 1.54" 1.61" 1.46" 1.45" .32"513-415E, 513-415T .98" .67" .61" 1.54" 1.61" 1.46" 1.75" .32"
Parallel TypeDimensions Unit: inchOrder Number A B C D E F G H513-282, 513-982 .70" .32" 1.45" 1.45" 2.26" .70" 2.08" .78"
Vertical TypeDimensions Unit: inchOrder Number B C D E F H513-453, 513-453T 2.01" .59" 1.54" .79" .2" .32"513-452, 513-452T 2.01" .78" 1.54" .79" .2" .32"
Dimensions Unit: inchOrder Number B C D E F H513-454T 2.01" .82" 1.54" .79" .2" .32"513-455T 2.01" .58" 1.54" .79" .2" .32"
Universal TypeDimensionsOrder Number A B C D E F G513-302, 513-942 1.05" .66" 1.96" 1.41" .90" 3.55" .59"513-304, 513-944 1.05" .66" 1.96" 1.41" .94" 3.59" .59"
TEST INDICATORS
R-123