+ All Categories
Home > Documents > 4ft LED Linkable Shop Light · LED Quantity 120 pcs Operating Voltage Range 120 VAC Operating...

4ft LED Linkable Shop Light · LED Quantity 120 pcs Operating Voltage Range 120 VAC Operating...

Date post: 05-Oct-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
2
4ft LED Linkable Shop Light Important: Read all instructions prior to installation. User Manual Part Number: 4ft LED Linkable Shop Light SLLP-NW4-42 Installation Manual Rev Date: V1 05/01/2017 Rev Date: V1 05/01/2017 Linking Fixtures Together Notes SLLP-NW4-42 SLLP-DC SLLP-I25, SLLP-I142 F M M M F Repeat installation steps for additional lights. Use interconnects to make power connections from one light to the next. Connections are made from socket “F” of the first light to socket “M” of the next light. The interconnects are also marked “F” and “M” and must be installed “F” to “F” and “M” to “M” when making connections. A maximum of 10 fixtures can be linked. Only connect to adjacent light fixtures. Pull chain does not switch power to additional fixtures. Link up to 10 fixtures together. Assure that the fixture is mounted onto a structurally sound ceiling that will support the fixture. The fixture is designed for use in 120VAC, 60Hz fused circuit. Do not use on a dimming circuit. Use hooks to support chain, not the electrical cord. • Do not install on radiant-heating type ceiling.
Transcript
Page 1: 4ft LED Linkable Shop Light · LED Quantity 120 pcs Operating Voltage Range 120 VAC Operating Temperature -4 ~ 104°F (-20 ~ 40 °C) Fixture Weight 5.2lbs (2.3 Kg) Warranty 5 Year

4ft LED Linkable Shop LightImportant: Read all instructions prior to installation.

User ManualPart Number:

4ft LED Linkable Shop LightSLLP-NW4-42

Installation Manual

5yrRev Date: V1 05/01/2017Rev Date: V1 05/01/2017

Linking Fixtures Together

Notes

SLLP-NW4-42

SLLP-DCSLLP-I25, SLLP-I142

F

M

M

M

F

Repeat installation steps for additional lights. Use interconnects to make power connections from one light to the next. Connections are made from socket “F” of the first light to socket “M” of the next light. The interconnects are also marked “F” and “M” and must be installed “F” to “F” and “M” to “M” when making connections. A maximum of 10 fixtures can be linked.

• Only connect to adjacent light fixtures.• Pull chain does not switch power to additional fixtures.• Link up to 10 fixtures together.• Assure that the fixture is mounted onto a structurally sound ceiling that

will support the fixture.• The fixture is designed for use in 120VAC, 60Hz fused circuit.

Do not use on a dimming circuit.• Use hooks to support chain, not the electrical cord.• Do not install on

radiant-heating type ceiling.

Page 2: 4ft LED Linkable Shop Light · LED Quantity 120 pcs Operating Voltage Range 120 VAC Operating Temperature -4 ~ 104°F (-20 ~ 40 °C) Fixture Weight 5.2lbs (2.3 Kg) Warranty 5 Year

SLLP-NW4-42

User ManualPart Number:

Installation Instructions For Single Light

4ft LED Linkable Shop LightImportant: Read all instructions prior to installation.

Rev Date: V1 05/01/2017

Specifications

SLLP-NW4-42Intensity 4500 lumenTotal Power Consumption 40 WattsCurrent Draw @ 120VAC 365 mAColor Temperature 5000KBeam Angle 150°CRI 82Dimmable NoConnection Type 3 Prong Grounded PlugIP Rating IP20LED Quantity 120 pcsOperating Voltage Range 120 VACOperating Temperature -4 ~ 104°F

(-20 ~ 40 °C)

Fixture Weight 5.2lbs (2.3 Kg)Warranty 5 Year

Included Parts

Recommended Accessories(sold separately)

1 - 4’ LED Shop Light4 - 12” Chain8 - “S” Hook2 - Ceiling Hook1 - Power Cord

10” Interconnect (SLLP-I25)

NOTE: A maximum of 10 fixtures can be linked.

Attach Ceiling Hooks

Attach “S” Hooks

Attach Hanging Chain

(FIG. 3)

(FIG. 2)

(FIG. 1)

1. Choose desired location of light fixutre. For an unfinished ceiling, use a pencil to mark where each ceiling hook should go. Drill 1/16th pilot holes and screw hooks appoximately 4ft apart.

2. For finished celing, use drywall anchors or toggle bolts (not included), or locate joists and install as in step 1 above.

1. Insert “S” hooks into holes on both ends of shop light. (FIG. 1)

1. Assemble hanging chains as show in FIG. 2 below.2. Crimp all “S” hooks closed (FIG. 3)3. Remove power socket cover labeled “M” and plug in powercord.4. Plug power cord into outlet. Use pull chain to power on.

Ceiling Hook Ceiling Hook

M

“S” Hooks

“S” Hooks

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

1 - Direct Interconnect (SLLP-DC)1 - 56” Interconnect (SLLP-I142)


Recommended