+ All Categories
Home > Documents > 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion...

5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion...

Date post: 19-Mar-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
14
INTERLOCKERS B-JAMB 4 1 4 " 2" 4 3 4 " EXT. INT. 4 3 4 " 4 3 4 " 2" 4 3 4 " STACK TRANSOM SILL over HEAD FIXED JAMB LEFT FIXED RIGHT FIXED TRANSOM JAMB 3 4 " 4 3 4 " 1 1 2 " EXTERIOR INTERIOR FIXED JAMB 2" B/L STD SILL TRANSOM HEAD O O Over OLXO CONFIGURATION EXTERIOR ELEVATION (INSIDE SLIDER SHOWN OUTSIDE SLIDER-AVAILABLE) X O O X O O OLXO OXRO NOT SHOWN X O O 1 2 3 4 5 6 7 8 9 2 1 2 " 1 5 8 " OUTSIDE INSIDE Nail Fin 1 1 2 " Head Filler 4 1 2 5 6 3 7 8 9 5 9 16 " 2" INT. 4 3 4 " EXT. OPTIONAL 5000 JUMBO BOTTOM RAILS w/ 2" B/L STD SILL 3 Recessed Nail Fin Option INTERIOR 2 1 2 " 4 3 4 " 3 4 " 2" 6 1 8 " 4 3 4 " 2 1 4 " 2" 4 3 4 " EXTERIOR Flush Nail Fin Option EXTERIOR EXTERIOR TRANSOM JAMB EXT. INT. As of: 05/15/19 ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf Scale: Function: Description: Detail: OF SHEET 5000 Series Sliding Doors Entrances Varies 3" = 1'-0" 1 14 40 1/2" A.F.F. TO CENTER OF PULL/PUSH 49 7/8" TO CENTER OF LOCKSET
Transcript
Page 1: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

INTERLOCKERSB-JAMB

414"

2"

434"

EXT. INT.

434"

434"

2"

434"

STACKTRANSOMSILL over

HEAD

FIXED JAMB

LEFTFIXED

RIGHTFIXED

TRANSOMJAMB

34"

434"

112"

EXTERIOR

INTERIOR

FIXED JAMB

2" B/LSTDSILL

TRANSOMHEAD O

O Over OLXO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

O X

O

O

OLXO

OXRONOT SHOWNX

O

O

1

2

3

4 5

6 7 8 9

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

Head Filler

41

2

5

6

3

7 8 9

5 916"

2"

INT.

434"

EXT.

OPTIONAL5000 JUMBO

BOTTOM RAILSw/ 2" B/L STD SILL

3

RecessedNail FinOption

INTERIOR21

2"

434"

34"

2"618"

434"

214"

2"

434"

EXTERIORFlushNail FinOption

EXTERIOR

EXTERIOR

TRANSOMJAMB

EXT. INT.

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 1 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 2: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

EXT. INT.

HEAD

EXTERIOR

INTERIOR

LATCH JAMBINTERLOCKERSFIXED JAMB MULLION

414"

2"

434"

EXTERIOR

OOX CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

XO

O

O

434"

34"

334"

1

2

3 4 5 6

1

3

2

4 5 6

118" 2"

418"

RecessedNail FinOption

FlushNail FinOption

212"

158"

Nail Fin11

2"

X O

X O

O

O

XOO CONFIGURATION

EXTERIOR

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 2 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 3: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

HEAD

INTERLOCKERSFIXED JAMB

434"

34"

212"

158"

LATCH JAMB

OX CONFIGURATION(1/4" Glazing)

EXTERIOR ELEVATION(INSIDE SLIDER SHOWN

OUTSIDE SLIDER-AVAILABLE)

X

O X

O

1

2

3 4 5

1

3

2

4 5

WITH REDUCING GASKET

434"

34"

118"

212"

2" 418"

5 116"

EXT. INT.

414"

2"

434"

FlushNail FinOption

RecessedNail FinOption

OX

XO CONFIGURATION

X O

EXTERIOR EXTERIOR

2" B/LSTDSILL

HEAD

434"

34"

212"

158"1

2

EXT. INT.

414"

2"

434"

1/4" Glass Reducer Insert for 1" Extrusion Panels

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 3 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
INTERIOR
Page 4: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

EXTERIOR

INTERIOR

LATCH JAMB

HEAD

INTERLOCKERS

INT.EXT.

INT.EXT.

FIXED JAMB

OX CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

(INTERIOR SCREEN)

XO

XO

278"

118"

512"

51316"

212"

158"

318"

512"

434"

414"

2"1"

118"

434"

212"

118"

2 116"

2"

512"

418"

234"

1

2

3 4 5

1

3

2

4 5

INT.EXT.

OPTIONAL5000 JUMBO

BOTTOM RAILSw/ 2" B/L STD SILL

3

318"

512"

434"

5 916"

2"1"

RecessedNail FinOption

FlushNail FinOption

X O

X O

XO CONFIGURATION

EXTERIOR

EXTERIOR

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 4 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 5: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

HEAD

B-JAMBINTERLOCKERS FIXED JAMB

414"

2"

434"

EXT. INT.

EXTERIOR

INTERIOR

434"

34"

2"

5 116"

618"

FIXED JAMB

OXRO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

O X

O

O

1

2

3 4 5 6

1

3

2

4 5 6

FlushNail FinOption

RecessedNail FinOption

2"

434"

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

Head Filler

XO

OX

O

O

OLXO CONFIGURATION

EXTERIOR EXTERIOR

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 5 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 6: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

HEAD

B-JAMB

EXT. INT.

FIXED JAMB

212"

158"

434"3

4"

414"

2"

434"

INTERLOCKERS FIXED JAMB

EXTERIOR

OXRO CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

O X O

XO O

1

2

3 4 5 6

1

3

2

4 5 6

EXTERIORFlushNail FinOption

Nail Fin

Head Filler

INTERIOR

618"

RecessedNail FinOption

2"

434"

OXO

X OO

OLXO CONFIGURATION

EXTERIOR

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 6 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 7: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

HEAD

EXT. INT.

EXTERIOR

318"

512"

434"

414"

2"1"

EXT. INT.

OXXO CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

- HI LOAD MEETING STILE & HI LOAD INTERLOCKERS

XO

O X

X

X

O

O

WITH INTERIOR SCREEN PANELS

1

2

1

3

2

4 5 6 7

HI-LOADINTERLOCKERS HI-LOAD

MEETING STILES

EXTERIOR

INTERIOR

FIXED JAMB FIXED JAMB

118"

434"

212"

HI-LOADINTERLOCKERS

3

4

5

6

7

Flush Nail Fin

RecessedNail Fin71

8"

OPTIONAL

614"

278"

118"

512"

51316"

212"

158" Head Filler

(ACTIVE)

OPTIONAL

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 7 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 8: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

HEAD

MEETING STILES

414"

2"

434"

EXT. INT.

EXTERIOR

INTERIOR2" 21

2"

434"

34"

EXTERIOR

OXXO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

XO

O X

X

X

O

O

INTERLOCKERSFIXED JAMB

434"

34"

2"

EXT.

INTERLOCKERS FIXED JAMB

1

2

3 4 5 6 7

1

3

2

4 5 6 7

RecessedNail FinOption

FlushNail FinOption

614"

212"

158"

Nail Fin11

2"

INT.

(ACTIVE)

Head Filler

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 8 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 9: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

EXT. INT.

HEAD

INTERLOCKERSLATCH JAMB FIXED JAMB

EXTERIOR

INTERIOR

EXTERIOR

XO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

(1/4" GLAZING)

X

X O

O

1

2

3 4 5

1

3

2

4 5

434"

34"

212"

158"

414"

2"

434"

434"

34"

118"

212"

2"418"

5 116"

FlushNail FinOption

RecessedNail FinOption

X

XO

O

OX CONFIGURATION

EXTERIOR

5 916"

2"

INT.

434"

EXT.

OPTIONAL5000 JUMBO

BOTTOM RAILSw/ 2" B/L STD SILL

2

Head Filler

2" B/LSTDSILL

HEAD

434"

34"

212"

158"1

2

EXT. INT.

414"

2"

434"

1/4" Glass Reducer Insert for 1" Extrusion Panels

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 9 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 10: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

EXT. INT.

HEAD

INTERIOR

LATCH JAMB INTERLOCKERS FIXED JAMB

414"

2"

434"

418"

434"

34"

212"

434"

34"

2"

EXTERIOR

XO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

X O

X O

1

2

3 4 5

1

3

2

4 5

RecessedNail FinOption

FlushNail FinOption

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

EXTERIOR

Head Filler

XO

EXTERIOR

XO

OX CONFIGURATION

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 10 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 11: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

EXT. INT.

HEAD

EXTERIOR

INTERIOR

LATCH JAMB INTERLOCKERS FIXED JAMBMULLION

414"

2"

434"

2"

358"

334"

418"

434"

34"

212"

434"

34"

2"

EXTERIOR

XOO CONFIGURATIONEXTERIOR ELEVATION

(INSIDE SLIDER SHOWNOUTSIDE SLIDER-AVAILABLE)

X O

X O

O

O

1

2

3 4 5 6

1

3

2

4 5 6

RecessedNail FinOption

FlushNail FinOption

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

XO O

XOO

EXTERIOR

OOX CONFIGURATION

Head Filler

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 11 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 12: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2" B/LSTDSILL

EXTERIOR

INTERIOR

LATCH JAMB

HEAD

INTERLOCKERS

EXTERIOR

XOO CONFIGURATIONEXTERIOR ELEVATION

(OUTSIDE SLIDER SHOWNINSIDE SLIDER-AVAILABLE)

X O

X O

O

O

212"

158"

434"

34"

414"

2"

434"

INT.EXT.

MULLION FIXED JAMB

434"

418"

5 116"

2"

334"

2"

31116"

212"

1

2

3 4 5 6

1

3

2

4 5 6

RecessedNail FinOption

FlushNail FinOption

Head Filler

XO

XO

O

O

EXTERIOR

OOX CONFIGURATION

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 12 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 13: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

EXTERIOR

INTERIOR

HEAD

EXTERIOR

O UNIT CONFIGURATIONEXTERIOR ELEVATION

O

O434"

34"

414"

2"

434"

INT.EXT.

FIXED "O"UNIT JAMB

434"

2" 118"

1

2

3 4

1

3

2

4

2" B/LSTDSILL

FIXED "O"UNIT JAMB

RecessedNail FinOption

FlushNail FinOption

EXT. INT.

212"

158"

OUTSIDE

INSIDE

Nail Fin11

2"

Head Filler

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 13 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET

Page 14: 5000 Series - Arcadia Inc2" b/l std sill ext. int. head exterior interior fixed jamb mullion interlockers latch jamb 41 4" 2" 43 4" exterior oox configuration exterior elevation (inside

2"

434"

2" B/L SILL

238"

434"

2 3/8" B/L SILL

3"

434"

118"

434"

1 1/8" B/L SILL

58"

434"

5/8" FLUSH SILL

4"

434"

3" B/L SILL

4" B/L SILL

SERIES 5000 ACCESSSORIES - OPTIONAL

HEAD withFLUSH FLANGE

312"

434"

4 716"

212"

8"

EXTERIOR

INTERIOR

312"

HIGH LOADMEETING STILES

(Inside Slider)

INT.EXT.

HEAD withRecessed NAIL FIN

434"

4"21

2"

INT.EXT.

112"

1 116"

212"

158"

434"

INT.EXT.

34" 1

2"

5 316"

HEAD with 1 PcHEAD RECEPTOR

EXTERIOR

INTERIOR

518"

434"

2"

5 316"

414"

2"

434"

6"

1"34"

INT.EXT.

LATCH JAMB with2 Pc JAMB RECEPTOR

STANDARD SILL with SUB SILL

6"

1"34"

"Z" TRACKEXTENDED SUB SILL

4"412"

514"

1"212"

212"

6 316"

518"43

4"11

8"

3 Pc PRESSURE PLATETO MULL TWO (2)

5000 DOOR TOGETHER

EXTERIOR

INTERIOR

5000 DOOR MULLING MEMBER

TO WINDOW

5"

1"

"L" SHAPEEXTENDED SUB SILL

HI-LOADINTERLOCKERS

MODERN

Head Filler Head Filler

Head Filler

4" HEAD

2 3/8" B/L SILL - 4" FRAME

4"

238"

4"

4" JAMB

158"

4"

118"

534"

2"

INT.EXT.

EXTERIOR

INTERIOR

INT.EXT.

118"

4"1 1/8" B/L SILL - 4" FRAME

As of: 05/15/19ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.pdf

Scale:

Function:Description:

Detail:OFSHEET

Z:\01 UPDATED FILES\01 CAD\02 ENTRANCES\02 SLIDERS\01.1 5000 SERIES\SERIES\ENTRANCE-ARCADIA-THERMAL-5000-ALL-SERIES.DWGJWeller

5000 SeriesSliding Doors

EntrancesVaries3" = 1'-0" 14 14

40 1/2" A.F.F. TO CENTER OF PULL/PUSH49 7/8" TO CENTER OF LOCKSET


Recommended