LONOKE
PINE BLUFF
STUTTGART
TEXARKANA82
EL DORADO
82
71
FT. SMITH
71
FORREST CITY
70
65
CLARKSVILLE
SPRINGS
BOONEVILLE
30
HOT
10
HARRISON
FAYETTEVILLE
BENTON
176
40
LITTLE ROCK
65
67
MTN. HOME
MARSHALL
62
GREENVILLE, MS
DUMAS
MEMPHIS, TN
79
40
67
BATESVILLE
62
STATE MAP
MONTICELLO
MAUMELLE
CABOT
JACKSONVILLE
OVERHEAD, OPPOSITE HAND
PREFINISHED
PROPERTY LINE
QUARRY TILE
RANGE, RADIUS
POUNDS/SQUARE FOOT
POUNDS/SQUARE INCH
POLYVINYL CHLORIDE
REFRIGERATOR
RIGHT OF WAY
REVISION, REVISED
ROUGH OPENING
REINFORCED CONCRETE PIPE
SPECIFICATION/SPECIFIED
STRUCTURAL
SQUARE YARD
WATER HEATER
WALL GUARD
WELDED WIRE FABRIC
WATERPROOFING,
WATER CLOSET
VINYL WALL COVERING
VINYL COMPOSITION TILE
VENT THRU ROOF
VERIFY ON JOB
VINYL EDGE STRIP
UNLESS NOTED OTHERWISE
TOP OF WALL
TOP OF SLAB, TOP OF STEEL
TOP OF GRATE FRAME
TOOLED JOINT
TEMPERED, TEMPORARY
TACK BOARD
WWF
LAVATORY LAV
MANUFACTURE
MASONRY OPENING
MH
MAN'F
MO
MANHOLE
WH
WD
W/O
WOOD
WITHOUT
SCHEDULE SCHED
EXTERIOR EXT
HEATING/VENTILATING/AIR-CONDITIONING
GL GLASS, GLAZING
HOLLOW METAL
GYPSUM WALL BOARD
INSIDE DIAMETER
HM
HOR
ID
INT
INV
JAN
JT
LAM
INSUL
HORIZONTAL
INTERIOR
INVERT
JANITOR
JOINT
LAMINATE
INSULATION
GYP BD
HB
HTG
HVAC
HR
HT
HDCP
GB
HOSE BIBB
HEATING
HANDRAIL
HEIGHT
HANDICAP
GRAB BAR
FLOOR DRAIN
FIRE HOSE CABINET
FIRE EXTINGUISHER CABINET
FROST-PROOF HOSE BIBB
FLOOR CLEANOUT
FLOOR (ING)
FINISH FLOOR
GAGE, GAUGE
GENERAL CONTRACTOR
FLR
FR
FRMG
FT
FTG
GA
GC
GALV
GEN
FRAME
FRAMING
FOOT, FEET
FOOTING
GALVANIZE
GENERAL
FIN
FEC
FD
FHB
FCO
FL
FF
FHC
FINISH
FLOW LINE
TOW
VTR
W/
WAINS
WG
WP
WC
VWC
VCT
WITH
WAINSCOT
VOJ
VES
VERT
VAR
UNO
TYP
TRTD
VERTICAL
VARIES
TYPICAL
TREATED
TELEPHONE TEL
TEMP
TJ
TOS
TOG
T&G
THK
THRESH
TLT
THRESHOLD
TONGUE
TOILET
THICK
SPEC.
SQ
STO
SUSP
STRUC
SY
TB
STD
SQUARE
STORAGE
SUSPENDED
STANDARD
DI DUCTILE IRON
EMERGENCY DRAIN
DOOR GRILLE
DISPENSER, DISPOSAL
ELEVATION, ELEVATOR
ELECTRIC WATER COOLER
EXPANSION JOINT
ED
ELEV
EWC
EMER
EQ
EXIST
EJ
EXP
ELEC
EMERGENCY
EQUAL
EXISTING
EXPOSED
ELECTRIC
DIA
DIM
DR
DS
DG
DTL
EA
DISP
DIAMETER
DIMENSION
DOOR
DETAIL
EACH
DOWNSPOUT
CHALK BOARD
CLEANOUT TO GRADE
CORNER GUARD
CONTROL JOINT
CORRUGATED METAL PIPE
CONCRETE MASONRY UNIT
CONTRACTOR
CONTINUOUS, CONTINUE
DRINKING FOUNTAIN
CONSTRUCTION
CMP
CMU
CONT
CONTR
CORR
DET
DF
CONST
CORRIDOR
DETAIL
CB
CI
CG
CO
COTG
CLR
COL
CJ
CONC
CAST IRON
CLEANOUT
CLEAR
COLUMN
CONCRETE
R
ROOF DRAIN RD
RM
SA
SHLVG
SHT
SHWR
SIM
SC
RO
ROOM
SUPPLY AIR
SHELVING
SHEET
SIMILAR
SOLID CORE
SHOWER
RE:
RCP
RA
REQ'D
RET
REV
ROW
REFR
REFERENCE
RETURN AIR
REQUIRED
RETAINING
PLYWD
PVC
PROV
PSF
PSI
PL
QT
PREFIN
PLYWOOD
PROVIDE
OH
OPG
OPP
PVMT
PERF
PL
PLAS
PR
PLBG
OPENING
OPPOSITE
PAVEMENT
PERFORATE
PLATE
PLASTIC
PAIR
PLUMBING
MECHANICAL
MEDICINE CABINET
METAL CORNER BEAD
METAL THRESHOLD
MISCELLANEOUS
NOT TO SCALE
NOT IN CONTRACT
OUTSIDE DIAMETER
BACK OF CURB
AIR CONDITIONING
ABOVE FINISH FLOOR
BENCH MARK, BEAM
CERAMIC TILE
BUILT-UP ROOFING
BRG
BM
BLK
BRKR
BLDG
BUR
CLG
CT
BLKG
BEARING
BLOCK
BREAKER
BUILDING
CEILING
BLOCKING
ABV
AC
ADDL
AFF
ACOUST
ALT
ASPH
BD
BC
ABOVE
ADDITIONAL
ALTERNATE
ASPHALT
BOARD
ACOUSTICAL
ABBREVIATIONS
MIR
MISC
MTL
NTS
OA
OC
OD
NIC
NOM
MIRROR
METAL
OVERALL
ON CENTER
NOMINAL
MAX
MECH
MC
MTL
MT
MIL
MIN
MCB
MAXIMUM
METAL
MILLIMETER
MINIMUM
SHEET NUMBER
BUILDING SECTION SYMBOL
ROOM NAME AND NUMBER
WINDOW TYPE SYMBOLA
DRAWING TITLE
INTERIOR ELEVATION SYMBOL
SHEET NUMBER
DETAIL NUMBER
DETAIL NUMBER
TOILET ACCESORY
ELEVATION OR WORK POINT
DOOR TYPE SYMBOL105
A
PLAN NORTH
NOTICE TO CONTRACTOR SAFETY NOTICE TO CONTRACTOR
SYMBOL LEGEND NOTES
CODE DATA
2. A PANIC BAR RELEASING DEVICE SHALL BE PROVIDED FOR ALL REQUIRED
1. ALL ADA TOILETS SHALL BE PROVIDED WITH GRAB BARS.
FOR ROOMS LARGER THAN TWENTY FEET IN ONE DIMENSION.
8. ALL DIMENSIONS SHOWN ARE NOMINAL. IT IS THE CONTRACTOR'S
3. FIRE AND SMOKE WALLS SHALL BE LABELED AS SUCH WITH THREE INCH TALL
PAINTED BLACK LETTERS ABOVE THE CEILING ON BOTH SIDES OF THE WALL
WITHIN EACH ROOM THAT ADJOINS SAID WALL AND AT TWENTY FOOT SPACING
4. ALL ACCESS PANELS SHALL BE A MINIMUM OF 2'-0" HIGH 2'-6" LONG.
5. ALL FLOOR FINISHES SHALL BE COMPLETELY FLUSH. CONTRACTOR TO USE
FLOOR LEVELING MATERIALS AS REQUIRED TO MAKE ALL NECESSARY
ALIGNMENTS. TAPER THINNER FLOOR MATERIAL 1/16" PER FOOT MAXIMUM.
6. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH ALL SEISMIC LOADS
7. FIXED EQUIPMENT ROUGH-IN INFORMATION SHOWN IS INTENDED TO
ESTABLISH SCOPE OF WORK ONLY. INFORMATION SHOWN SHALL BE VERIFIED
WITH OWNER'S VENDOR INSTALLATION DOCUMENTS PRIOR TO CONSTRUCTION.
FOR ITS ZONE.
EXIT DOORS.
SCALETITLE
STSTL STAINLESS STEEL
WALL SECTION SYMBOL
DETAIL TAG
STL STEEL
OCEW ON CENTER EACH WAY
FORREST CITY
PROJECT:
1335 NORTH WASHINGTON ST.
OWNERSHIP OF DOCUMENTS
FORREST CITY, ARKANSAS 72335
CIVIC CENTER ADDITION
PROJECT DATA
RESPONSIBILITY FOR PROPER FIT OF ALL COMPONENTS.
MAS MASONRY
MBU
MODIFIED BITUMEN UNDERLAYMENT
STRUCTURAL DRAWINGS SD
CIVIL DRAWINGS CD
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
GA
GA
GA
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
ON
AUTHO
ITA
ZIR
CATE
OF
EC
RTIFI
REESS
ETC
ARKANGN IE N
No. 365
A
ENGINEERSINC.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
183905CFC
11 /21 / 2018
1. UNLESS NOTED OTHERWISE SPRINKLERS SHALL BE STANDARD UPRIGHT
TYPE WITH
1
2
OR
17
32
INCH ORIFICE AND RATED FOR A MINIMUM OF 165
DEGREE F AND LIGHT HAZARD CATEGORY.
2. THE SPRINKLER CONTRACTOR SHALL DESIGN THE SYSTEM TO FULLY COORDINATE
WITH THE ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS
OF THE PROPOSED STRUCTURE IN ACCORDANCE WITH NFPA 13.
3. THE SPRINKLER CONTRACTOR SHALL PROVIDE COMPLETE DESIGN DRAWINGS
AND HYDRAULIC CALCULTIONS, STAMPED AND CERTIFIED BY A PROFESSIONAL
ENGINEER OR REGISTERED FIRE SPRINKLER SPECIALIST LICENSED IN THE
STATE OF ARKANSAS.
4. ALL SPRINKLER SYSTEM WORK SHALL BE PERFORMED BY A LICENSED
CONTRACTOR IN ACCORDANCE WITH STATE AND LOCAL LAW AND BUILDING
CODE JURISDICTIONS AND ENGINEER OF RECORD.
5. SPRINKLER CONTRACTOR SHALL PROVIDE SUPPORT AND BRACING SHOP
DRAWINGS FOR FINAL PIPING LAYOUT. INSTALL AND BRACE PIPING PER
NFPA 13: 9.3.5.3 AND 9.3.5.6.
6. UNLESS INDICATED OTHERWISE, SPRINKLER HAZARD CATEGORY IS LIGHT
DUTY. AND MINIMUM ACCEPTABLE PRESSURE SAFETY FACTOR SHALL
BE TEN PERCENT (10%) OF CALCULATED FLOW.
7. SPRINKLER SYSTEM SHALL BE MONITORED PER NFPA 13 AND LOCAL
REQUIREMENTS. SPRINKLER CONTRACTOR SHALL COORDINATE FINAL
DESIGN WITH THE EXISTING FIRE ALARM SYSTEM.
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
GA
GA
GA
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
ETC
No. 365
ENGINEERSINC.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
AREA OF PROPOSED WORK(LIMIT OF ASPHALT SEAL COATING)
183905CFC
11 /21 / 2018
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
GA
GA
GA
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
ETC
No. 365
ENGINEERSINC.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
GENERAL NOTE:UTILITIES SHOWN WITHIN THE EXTENT OFCONSTRUCTION HAVE EITHER BEEN OBTAINED FROMAS-BUILT DRAWINGS OR ABOVE GROUND FEATURESSUCH AS FIRE HYDRANTS, VALVES, OR METERS. THECONTRACTOR SHALL BE RESPONSIBLE FOR LOCATINGTHE EXACT LOCATION OF UTILITIES PRIOR TO ANYEXCAVATION BY CALLING ONE-CALL AT 1-800-482-8998.THE UTILITY LOCATION MARKING SHALL BE MAINTAINEDUNTIL NO FURTHER EXCAVATION IS REQUIRED.
GENERAL NOTES:
1. THE BIDDERS ARE ENCOURAGED TO VISIT THE SITE PRIOR TO BIDDING.
2. THE BIDDERS SHALL COMPLY WITH ALL APPLICABLE LAWS, CODES AND ORDINANCES GOVERNING
WORK OF THIS TYPE.
3. THE CONTRACTOR AWARDED CONTRACT SHALL BE SOLELY RESPONSIBLE FOR DAMAGE TO ANY
EXISTING FACILITIES WHICH ARE TO REMAIN.
4. BENCH MARK HAS BEEN NOTED THROUGHOUT THE PLANS. THE CONTRACTOR IS FULLY RESPONSIBLE
TO LAYOUT/STAKE OUT WORK SHOWN ON THE PLANS.
5. ALL DISTURBED AREA SHALL BE RETURNED TO ORIGINAL CONDITION.
6. REFERENCES TO MANUFACTURE'S NAME AND MODEL IS TO ESTABLISH A BENCH MARK FOR PHYSICAL
STANDARD AND PERFORMANCE QUALITY. THE CONTRACTOR CAN SUBSTITUTE THE PRODUCT WITH A
PRODUCT BY OTHER VENDORS. HOWEVER THE CONTRACTOR MUST OBTAIN APPROVAL PRIOR TO SUCH
SUBSTITUTIONS. SEE SPECIFICATIONS.
GENERAL SITE UTILITY CONSTRUCTION NOTES:
1. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANIES PRIOR TO ANY EXCAVATION. ANY
DAMAGE TO UTILITY LINES CAUSED BY THE CONTRACTORS OPERATION SHALL BE REPAIRED AT THE
CONTRACTORS EXPENSE.
EXISTING SIDEWALKTO REMAIN
EXISTING SIDEWALKSTO REMAIN
SCALE: 1" = 10'-0"
183905CFC
11 /21 / 2018
EXIST. DOORNEW BRICK VENEER
TO MATCH EXIST.o/CONCRETE BLOCK
EXISTING BRICK VENEERo/CONCRETE BLOCK
EXTERIOR WALL
PAN
EL-S
STL. GUARDRAILSEE 1/A2.1
1 4" /
FT.
A
A
STL. GUARDRAILSEE 1/A2.1
CONC. LANDING
CURB RAMPSEE SITE PLAN
CURB RAMPSEE SITE PLAN
STL. GUARDRAILSEE 1/A2.1
SLOPE LANDING@ 14" PER FT.
GALV. ANGLE 6x6x12
EDGE PROTECTIONPAINT
14"= 1'-0"
1 4" /
FT.
A
14"= 1'-0"
6" MTL.STUD WALL
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
GA
GA
GA
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
ETC
No. 365
ENGINEERSINC.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
SCALE: 1" = 10'-0"
SCRAPE ALL DIRT, WEEDS ANDDEBRIS FROM EXISTING ASPHALT,POWERWASH & PROVIDE NEWASPHALT SEAL COAT OVER ENTIREAREA INDICATED
NEW ADA ACCESSIBLERAMP TO NEW ADDITION
3'-6"
18"
1'-8"
1'-8"
BACKGROUND
4" WHITE STRIPE (TYP.)
ON A BLUE SQUARE
8" 2'-8"
4"
2'-8"
1'-8"
4"
4'-0"
GREEN BORDER
PARKINGRESERVED
GREEN LETTERING
18"x12"
BLUE
NOTE:R7-8 MANUAL OF UNIFORM TRAFFIC CONTROL DEVICESSIGNS WILL BE MOUNTED WITH THE BOTTOM EDGE 7'-0"ABOVE FINISHED GRADE.
WHITE
ADA SPACE ( SIGN AND PAINTING )
SQUARE 2x2 TUBE OF .063 ALUMINUMWITH PERMANENT WEATHERPROOF
ALUMINUM CAP. PAINT POSTAL BLUE,MATTE FINISH
STEEL TROWEL FINISH
FINISH GRADE OR FINISH PAVING
CONCRETE BASE
GRAVEL SIGN MOUNTING NOTES:FOR POST MOUNTING, USE NON-
CORROSIVE 3/8" MACHINEBOLTS W/ WASHERS, 2 PER SIGN.FOR WALL MOUNTING, USE NON-
CORROSIVE 3/8" LAG BOLTSW/ LEAD EXPANSIONSHIELD, 4 PER SIGN.
NOTES:BOTTOM OF FOOTING TO BE 1'-0" BELOW FROST
LINE, EXISTING UNDISTURBED GRADE ORFINISHED GRADE,WHICHEVER IS GREATER.
CONCRETEENCASEMENT
AROUND POLE
ADA SPACE SIGN POLE BASE
PAINT AS OUTER SHAPEAS SHOWN ON PLAN SHEETBLUE TRAFFIC PAINT
ACCESS AISLE PAINTING
183905CFC
11 /21 / 2018
1/4 : 12
1/2 : 12
1/2 : 12
FULLY ADHERED 50 MILPVC MEMBRANE AS SPEC.
o/3/8" COVER BOARD o/2-LAYERS OF 11
2" POLYISO.INSUL. BD. STAGGER JOINTS
o/MTL. DECKING
MASONRY BOND
BM. HEADER w/
2-#5 CONT. & #3
@ 24" O.C.
3"= 1'-0"
CONT. CLEAT
TAPERED RIGID
FOAM BD.
MIN. 24 GA.G.I.
CAP FLASH w/
KYNAR 500 FINISH
LINE OF EXIST.
MANSARD ROOF
EXIST. BRICK VENEER
o/CMU WALL
A
UP 4R @ 558", 3T @ 12"
HANDRAIL BOTH SIDES
A
OVERFLOW DRAINw/DRAIN NOZZLEROOF DRAINw/DRAIN NOZZLE
F.D. CONN.
EXIST. DOOR TOFIRE RISER ROOM
EXIST. CONC. LANDING& SIDEWALK
GALV. ANGLE 6x4x12
EDGE PROTECTIONPAINT
CONCRETE LANDING
MANSARD STYLE ROOFBEYOND 2 EXIST. BLDG.
FULLY ADHERED MIN. 50 MILPVC ROOFING MEMBRANEFLASHED AGAINST EXIST.
BRICK WALL BEYOND, SEE 7/A1.2
2-LAYERS OF 1/1/2" RIGID POLYISO.BOARDS, STAGGER JOINTS TYP.
MIN. 24 GA. G.I. MULTI-RIBBEDMETAL DECKING
8" x MIN. 12 GA. GALV. STRUC. MTL.'CEE' PURLINS @ 3'-0" O.C. SEE S1.2
78" GALV. MTL. HATCHANNELS @ 24" O.C.
58" GYP. BD. w/LIGHTTEXTURED FIN. - PAINT
CMU WALLS - PAINT TYP.
PENDANT HUNG LEDSTRIP LIGHT FIXTUREPER ELEC. DWGS.
EXIST. BRICK WALLBEYOND - SEAL w/
CLEAR COAT MASONRYSEALER TYP.
EXIST. HM DOOR &FRAME BEYOND - PAINT
EXIST. ASPHALT
MAINTAIN TOP OF PARAPET1" BELOW BOTTOM OF MANSARD
CMU WALLS - PAINT TYP.
PENDANT HUNG LEDSTRIP LIGHT FIXTUREPER ELEC. DWGS.
PAINT CONCRETEFLOORS SEE FIN.SCHEDULE
FINISHED FLOOR FINISHED FLOOR
FULLY ADHERED MIN. 50 MILPVC ROOFING MEMBRANEFLASHED AGAINST EXIST.
BRICK WALL BEYOND
2-LAYERS OF 1/1/2" RIGID POLYISO.BOARDS, STAGGER JOINTS TYP.
MIN. 24 GA. G.I. MULTI-RIBBEDMETAL DECKING
8" x MIN. 12 GA. GALV. STRUC. MTL.'CEE' PURLINS @ 3'-0" O.C. SEE S1.2
78" GALV. MTL. HATCHANNELS @ 24" O.C.
58" GYP. BD. w/LIGHTTEXTURED FIN. - PAINT
PENDANT HUNG LEDSTRIP LIGHT FIXTUREPER ELEC. DWGS.
FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR
PAINT CONCRETEFLOORS SEE FIN.SCHEDULE
CMU WALLS - PAINT TYP.
CMU WALLS - PAINT TYP.
1
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
GA
GA
GA
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
ON
AUTHOI
TAZI
RCATE
OF
EC
RTIFI
REESS
ETC
ARKANGN IE N
No. 365
A
ENGINEERSINC.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
183905CFC
11 /21 / 2018
6 6 6 6
EXIST. DOOR
S-6
HP
-1
S-2,4
S-1,3
S-5,7
S-8,10
S-12
S-12
S-9,11
S-12
S-12
S-12
S-12
S-12
S-15
S-6
S-6
S-6
S-13
S-13
S-15
S-15
S-15
S-17
S-17
PANEL-S
EU-1
EU-2
EU
-3
CREE
EXTERIOR
GROUND MOUNTED
66 LED GROUND MOUNTED FLOOD LIGHT
FIELD INSTALLED ACCESSORIES
BY CONTRACTOR
FLD - OL-15-D2-14-D-UL-700-DIM
PRESCOLITE
17.8 6" DIA. RECESSED LED
LC6SL-6LCSL14L40K8WT-SCA6D7
PRESCOLITE
17.8
6" DIA. RECESSED LED w/EMERGENCY
BATTERY BACK-UP
LC6SLEM-6LCSL14L40K8WTEM-SCA6D7
FLUSH @ CEILING
FLUSH @ CEILING
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
183905CFC
10 /16 / 2018
WA
WA
WA
0_CURRENT CIVIC CENTER MECHANICAL.DWG
SCALE: 1/4" = 1'-0"
HVAC PLAN1
FANS
MARKMFR.
MODELLOCATION
CFM
FAN DATA
S.P. DRIVE RPMMAX
SONESHP
VOLT/PHASE
DAMPERTYPE
ELEC. DATA OPTIONS
ROOFCURB
DISC.SWITCH
OTHER ASNOTED
T'STAT EMCSOTHER AS
NOTED
CONTROL INTERLOCKS
NOTES
NOTES:1. PROVIDE ADDITIONAL SLEEVE AS NECESSARY FOR THE ADDITIONAL WALL THICKNESS
SPLIT SYSTEM HEAT PUMP
HP - 1 LG
MARK MFR.MODEL NUMBERS
NOM.TONS
2.0
OUTDOOR UNIT
LMU24CHV
COOLING DATA
RATEDMBH
20.0
MIN.SEER
21.7
HEATING DATA
OUTPUTBTUH
24,000
AUX
N/A
ELECTRICAL DATA
CONDENSORVOLT/Ø
208-230/60/1
QTYCOMPRESSOR
1 9.4
RLA FLAFAN
0.59
MCAUNIT POWER
14.3
BRK
20
GENERAL NOTES:1. ALL DUCT DIMENSIONS REPRESENT FREE AREAS. ADJUST FOR INSULATION.2. CLOSELY COORDINATE LOCATIONS OF INSTALLED EQUIPMENT TO ACHIEVE THE GREATEST ACCESSIBILITY FOR MAINTENANCE PURPOSES.3. REFRIGERANT PIPING SHOWN ON THESE PLANS IS FOR REFERENCE. PIPING SHALL BE PER MANUFACTURER DIRECTIONS AND
PROCEDURES.4. HORIZONTAL REFRIGERANT PIPING SHALL NOT EXCEED 5° UP OR DOWN. PIPING BE FREE OF TRAPS, SAGGING PIPES, SIGHT GLASSES AND
FILTER DRYERS.5. ALL REFRIGERANT PIPING SHALL BE STORED, HANDLED AND INSTALLED PER MANUFACTURER DIRECTIONS:
5.1. STORE PIPE STOCK IN A DRY PLACE CAPPED AND CLEAN5.2. BLOW CLEAN ALL PIPE SECTIONS WITH DRY NITROGEN BEFORE ASSEMBLY5.3. DO NOT USE FLUX, SOFT SOLDER, OR ANTI-OXIDANT AGENTS5.4. DO NOT USE A SAW TO CUT PIPE5.5. USE DRY NITROGEN PURGE OPERATING AT A MINIMUM PRESSURE OF THREE PSIG AND MAINTAIN A STEADY FLOW WHEN BRAZING5.6. USE A 15% SILVER PHOSPHOROUS COPPER BRAZING ALLOY TO AVOID OVERHEATING AND PRODUCE GOOD FLOW5.7. PROTECT ISOLATION VALVES, ELECTRONIC EXPANSION VALVES AND OTHER HEAT-SENSITIVE CONTROL COMPONENTS FROM
EXCESSIVE HEAT WITH A WET RAG OR A HEAT BARRIER SPRAY PRODUCT6. REFRIGERANT PIPING SHALL BE SUPPORTED A MAXIMUM OF 5' O.C. PER MANUFACTURER DIRECTIONS NOT COMPRESSING INSULATION
EF - 1
EF - 4
EF - 5
BROAN508
RESTROOMWALL
150 0.100 DIRECT 1,625 6.0 --- 120/1 GRAVITY NO NO NO NO NOON WITH LIGHTS, PROVIDE SPEED CONTROL MOUNTED BESIDE FAN IN A RECESSEDBOX
BROAN508
RESTROOMWALL
150 0.100 DIRECT 1,625 6.0 --- 120/1 GRAVITY NO NO NO NO NOON WITH LIGHTS, PROVIDE SPEED CONTROL MOUNTED BESIDE FAN IN A RECESSEDBOX
HP - 1
INDOOR HEAT PUMP UNITS
EU - 1 LG
MARK MFR.ASSOCIATED
OUTDOOR UNIT
HP-1
CFM OSANOM.TONS
254 N/A 0.58
NOTES:1. PROVIDE FULL-PORT ISOLATION BALL VALVES WITH SCHRADER PORTS (BETWEEN VALVE AND INDOOR UNIT) ON ALL INDOOR UNITS.
LMN079HVT
AIR FLOW COOLING DATA
TOTALMBH
7.0
HEATING DATA
OUTPUTBTUH
8,100
AUX
N/A
ELECTRICAL DATA
INDOOR UNITVOLT/Ø
208-230/60/1
FLA
0.4
BRK
N/A
EU - 2
EU - 3
HP-1
HP-1
LG
LG
MODEL NUMBER
INDOOR
FLAINDOOR
2.00
1
1
LMN079HVT
LMN079HVT
254 N/A 0.58 7.0 8,100 N/A 208-230/60/1 0.4 N/A
254 N/A 0.58 7.0 8,100 N/A 208-230/60/1 0.4 N/A
EU - 1
EU - 2
EU - 3
EF - 2
MOUNT 5' AFF WITHMAXWELL WAFP24
MOUNTING BRACKETS
DRAWING:
JOB NO:
SHEET
DATE
SURVEY BY:
CHECKED BY:
DRAWN BY:
DESIGN BY:
DATE REVISION
CO
PY
RIG
HT
2015
ETC
EN
GIN
EE
RS
, IN
C.
FOR
RE
ST
CIT
Y
AR
KA
NS
AS
183905CFC
10 /16 / 2018
WA
WA
WA
0_CURRENT CIVIC CENTER MECHANICAL.DWG
SCALE: 1/4" = 1'-0"
PLUMBING FLOOR PLAN2
2" SERVICE68 FU57 GPMTO 5' OUTSIDE BUILDING
2"
SHUT-OFF VALVEIN RISER
1. FINISHES ON ALL FAUCETS, FLUSH VALVES, ETC. TO BE POLISHED CHROME UNLESS INDICATED OTHERWISE.
NOTES
ZURN Z-1400 "HEAVY DUTY" DURA-COATED CAST IRON CLEANOUT WITH ROUND HEAVYDUTY, SCORIATED NON-TILT CAST IRON TOP
ZURN Z-1440-1 FOR DRYWALL OR BLOCK. Z-1441 FOR PLASTER OR TILE. WITHCURA-COATED CAST IRON FERRULE AND CADMIUM PLATED CAST IRON COUNTERSUNKPLUG AND SMOOTH NICKEL BRONZE ACCESS COVER
DESCRIPTION
JANITOR SINK
CLEAN OUT TO GRADE
WALL CLEAN OUT
WATER HAMMER ARRESTOR
MARK WASTE COLDWATER
HOTWATER
MOUNTING REFERENCE PRODUCT COMMENTS
PLUMBING FIXTURE AND ACCESSORY SCHEDULE
3"
12" OR 3 4" ---
INSTALL ONE WATER HAMMER ARRESTOR AT END FIXTURECONNECTION OF EACH MAIN FIXTURE GROUP
MOUNT WITH WADE 520-07-M19 CARRIER
TRAP GUARD BY PROSET SYSTEMS, 2" WITH NICKEL BRONZE TOP, MODEL T25630-F-PFLOOR DRAIN 2"
S - 1
FD - 1
WCO
COTG
WHA
STERN WILLIAMS MTB-2424 WITH DEEP SEAL P-TRAP. PROVIDE T-10-VB OR SYMMONSS-2490 WALL-MOUNT UTILITY FAUCET WITH VACUUM BREAKER.
AMERICAN STANDARD WASHBROOK WITH SLOAN G2 OPTIMA PLUS IR FLUSH VALVEMODEL 8186-0.5 (0.5 GPF, 15 - 100 PSI)ADA URINALUR - 2 2" 3
4" WALL
DRINKING FOUNTAINDF - 1 2 X 3 8"2 X 1 14"
FPHBWOODFORD MODEL 67 OR EQUAL, BRASS CONSTRUCTION, WITH VACUUM BREAKER, 3/4"MALE HOSE THREAD.
FREEZE PROOF HOSE BIBB
AMERICAN STANDARD RONDALYN MODEL 0491.019 4" CENTERS WITH MONTERREY MODEL5500.174 FAUCET.
12"LAVATORYL - 1
ZURN ZN-1400 "LEVEL-TROL TUF-TOP" DURA-COATED CAST IRON WITH ROUND,SCORIATED NICKEL BRONZE TOP, ADJUSTABLEFLOOR CLEAN OUT
PERPIPESIZE
FCO
1 14"
---
---
PERPIPESIZEPERPIPESIZE
---
---
---
---
---
---
---
---
---
------
---
12" 1
2"
12"
34"
FLOOR
FLOOR
FLOOR
FLOOR
FLOOR
WALL
WALL
DROP-INCOUNTER
WATTS SERIES LF05, USE 3 4" ON 3 4" AND LARGER PIPE
WH-2 WATER HEATER --- 12"1
2" EEMAX THERMOSTATIC TANKLESS WATER HEATER MODEL EX4208ML, 208V, 4.1KWWALL UNDERCOUNTER
HALSEY TAYLOR OVL II ESBP BI-LEVEL FOUNTAIN. PROVIDE TRAPS AND STOPS. MOUNTPER MANUFACTURER DIRECTIONS.
AMERICAN STANDARD MADERA FLOWISE MODEL 3451.712, 1.28 GPF, 15" HIGHELONGATED BOWL, VITREOUS CHINA (WHITE), ELONGATED OPEN FRONT MODEL 5901.100SEAT, SLOAN G2 OPTIMA PLUS MODEL 8111-1.28 FLUSHOMETER VALVE.
AMERICAN STANDARD MADERA FLOWISE MODEL 3461.128, 1.28 GPF, 16 12" HIGHELONGATED BOWL, VITREOUS CHINA (WHITE), ELONGATED OPEN FRONT, MODEL5901.100 SEAT, SLOAN G2 OPTIMA PLUS MODEL 8111-1.28 FLUSHOMETER VALVE.
WATER CLOSET
ADA WATER CLOSET
WC - 1
WC - 2INSTALL W/SEAT AND FLUSH VALVE HANDLE PER A.D.A.REQ'TS
4"
4"
1"
1" ---
--- FLOOR
FLOOR
WH-1 WATER HEATER --- 12"1
2" EEMAX THERMOSTATIC TANKLESS WATER HEATER MODEL EX4208T, 208V, 4.1KWWALL
2"2"
112"
112"
112"2"
112"
2"
SCALE: N.T.S.
WASTE & VENT RISER DIAGRAM1
WH-1
WH-2
S-1
WC-2 WC-1 WC-1
WC-2 WC-1
UR-2
L-1 L-1
L-1 L-1
FPHB
FD-1
FD-1
DF-1
34"
114" 11
2"
114" 3
4" 34" 5
8" 38"
FCO 4" SERVICE33 DFUTO 5' OUTSIDE BUILDING
EXTEND EXISTING 4" PVC ROOF DRAINAND TIE INTO NEW ROOF DRAIN PIPING
ROOF DRAIN AND OVERFLOW.PIPE DOWN AND THROUGH WALL,
OVERFLOW ABOVE DRAIN.SEE ARCHITECTURAL FOR DETAILS.
RD
ROOF DRAINS --- ROOFREFER TO ARCHITECTURAL FOR SUMP DETAILS. PROVIDEZ199 DOWNSPOUT NOZZLES. INSTALL OVERFLOW NOZZLEABOVE DRAIN NOZZLE.
RD --- --- ZURN Z165 COMBINATION MAIN ROOF & OVERFLOW DRAIN, 3"
XXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXX
X X X X X
X X X X X X
X X X X X X X X
DRAIN ROCK
10 MIL VAPORBARRIER
6" DRAIN ROCK
SELECT STRUC.FILL-COMPACTED
TO 95% DENSITY
EXIST. ASPHALT
4" CONC. SLABw/6x6x6
6 WWF @ CENTERo/6" DRAIN ROCK o/10 MILVAPOR BARRIER
SELECT STRUC.FILL-COMPACTEDTO 95% DENSITY
EXIST ASPHALT
2 12" x 2 12" x 18" x 6" GALV.STL. TUBE SLEEVE FOR2 12" x 2 12" x 14" GUARDRAILPOSTS, SEE FOUND PLAN
SLOPE SLAB 14" PER FT.
8-#5 CONT. w/#3 TIES@ 24" O.C.
4-#5 CONT.  @ 24" O.C.
1-#5 CONT. @TREAD NOSING
1" RADIUS
12" EXP. JT.
FIN. FLR.
FIN. FLR.
2-#5 CONT. @ 12" O.C.w/#3 TIES @ 24" O.C.
SELECT STRUC.FILL-COMPACTEDTO 95% DENSITY
EXIST ASPHALT
GALV. ANGLE 6x4x12
LLV w/1/2" x 5' EPOXYSET BOLTS @ 24" O.C.
4" CONC. SLABw/6x6x6
6 WWF @ CENTERo/6" DRAIN ROCK o/10 MILVAPOR BARRIER
1 14" DIA.x 316" STL. PIPE
HANDRAIL - WELDEDTO GALV. ANGLE-PAINT
1 12" DIA x 18" x 6" GALV.STL. PIPE SLEEVE FOR1 14" DIA. x 3
16" PIPEHANDRAIL POSTS TYP. OF 4
2 12" x 2 12" x 18" x 6" GALV.STL. TUBE SLEEVE FOR2 12" x 2 12" x 14" GUARDRAILPOSTS - TYP. OF 7
S1.1
BITUMINOUS MEMBRANEFLASHING - MIN. 2-COURSESHIGH
TERMINATION BAR
MORTAR NETTING
WEEPS @ 16" O.C.
SOLID GROUT FILL
12" EXP. JT. EXIST. ASPHALT
REPAIR AS REQD.SELECT STRUC.FILL-COMPACTED
TO 95% DENSITY
CONT. P.T. 2x12
1/4 : 12
11/4" x 24 GA.GALV. MTL DECK
CONT. P.T. 2x12