6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
ISOLUX INGENIERA, S.A.MINISTRY OF ELECTRICITY
AND WATER
6M.7 FIRE FIGHTING AND DETECTION SYSTEMItem No. Description Particulars
1. Fire protection water
distribution (ring main)
system1.1 Design Code NFPA
1.2 Total water flow to feed
largest risk area
l/min 5000
1.3 Design Pressure Bar 12.5
1.4 Design Temperature C
1.5 Operating Pressure Range Bar
1.6 Normal pressure in ring
main
Bar
1.7 Pressure at which pressure
maintaining device starts
Bar
1 8 Pressure at which first pump Bar
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
2/17
1 8 Pressure at which first pump Bar
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
ISOLUX INGENIERA, S.A.MINISTRY OF ELECTRICITY
AND WATER
Item No. Description Particulars
2. Fire Hydrant System
2.1 Outdoor hydrants:
2.2 Type/Model Number
2.3 Manufacturer
2.4 Design Codes/Class NFPA 24
2.5 Quantity
2.6 Max spacing of fire hydrants m 60
2.7 Size mm 150
2.8 Discharge per hydrant outlet
valve (2 Nos.
65 mm each)
l/min
2.9 Design Pressure bar
2.10 Design Temperature C
2.11 Operating pressure (in/out) bar
2.12 Minimum operating pressure bar
2.13 End style
O
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
3/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
ISOLUX INGENIERA, S.A.MINISTRY OF ELECTRICITY
AND WATER
Item No. Description Particulars
2.19 Fire hydrant post indicator
valves:
2.19.1 Type/Model Number Butterfly
2.19.2 Manufacturer
2.19.3 Design Code
2.19.4 Quantity
2.19.5 Size
2.19.6 Body material
2.19.7 Internal materials
2.19.8 Building/plant areas:2.19.9 Breeching inlet (No., size
and threads)
No/mm
3. Standpipes and hose
cabinet
3.1 Type/Model Number
f
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
4/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
ISOLUX INGENIERA, S.A.MINISTRY OF ELECTRICITY
AND WATER
Item No. Description Particulars
3.14 Fire hose: Rack Type
3.14.1 Type/Model Number
3.14.2 Manufacturer
3.14.3 Design Codes/Class
3.14.4 Quantity
3.14.5 Length
3.14.6 Material
3.15 Hose couplings:
3.15.1 Type/Model Number
3.15.2 Manufacturer3.15.3 Pressure rating
3.15.4 Material
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
5/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
Item No. Description GOPH/ Gas
ConditioningBuilding
Gas
Turbinearea
Diesel
generatorunits
Others
4. Automatic foam/water
spray systems
4.1 General
4.1.1 Foam concentrate type
4.1.2 Manufacturer
4.1.3 Design Code
4.1.4 Mixture rate %
4.1.5 Specific gravity
4.1.6 Maximum useable
temperature
oC
4.1.7 Quantity provided litres
4.1.8 Guaranteed life years
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
6/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
Item No. Description Gas Turbine area Diesel generatorunits
Others
4.2 Diaphragm Pressure
Proportioner
4.2.1 Ratio controller
4.2.2 Quantity
4.2.3 Type/model No.
4.2.4 Manufacturer
4.2.5 Size mm
4.2.6Flow rate l/sec
4.2.7 Diaphragm tank:
4.2.7.1 Quantity
4.2.7.2 Type/model No.
4.2.7.3 Manufacturer
4.2.7.4 Capacity litres
4.2.8 Valves:
4.2.8.1 Valve type
4.2.8.2 Materials:
4.2.8.3 Body
4.2.8.4 Internals
4.2.8.5 Seal
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
7/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
Item No. Description Gas Turbine area Diesel generatorunits
Others
4.2.9 Hydraulic/electric ball
valves:
4.2.9.1 Valve type
4.2.9.2 Materials:
4.2.9.3 Body
4.2.9.4 Internals
4.2.9.5 SealTenderer to indicate
other areas providedwith DiaphragmPressure ProportionerSystem
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
8/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIERA, S.A.
Item
No
Description Particulars
4.3 Balanced
proportioning
equipment
4.3.1 Ratio controller:
4.3.2 Quantity
4.3.3 Type/model No.
4.3.4 Manufacturer
4.3.5 Size mm
4.3.6 Flow rate l/sec
4.3.7 Proportioning control
valve:
4.3.7.1 Quantity
4.3.7.2 Type/model No.
4.3.7.3 Manufacturer
4 3 7 4 Size
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
9/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIERA, S.A.
Item
No
Description Particulars
4.3.9.3 Manufacturer
4.3.9.4 Rated Capacity l/s
4.3.9.5 Net positive suction
head at rated capacity
m
4.3.9.6 Maximum power
absorbed by pump
kW
4.3.9.7 Discharge pressure at
rated capacity
bar
4.3.9.8 Discharge pressure
against closed valve
bar
4.3.9.9 Speed rpm
4.3.9.10 Pump inlet connection
diameter
mm
4.3.9.11 Pump discharge
connection diameter
mm
4.3.9.12 Weight kg
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
10/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIERA, S.A.
Item
No
Description Particulars
5.3 Number of carbon
dioxide type provided
5.4 Capacity of carbon
dioxide extinguishers
kg
5.5 Number of water
extinguishers
5.6 Capacity of water
extinguishers
L
5.7 Number of foam type
provided
5.8 Capacity of foam
extinguishers
L
6. Gas extinguishing
system
6 1Gas turbine noise
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
11/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIERA, S.A.
Item
No
Description Particulars
7.5 Volume required tomaintainconcentration for
required period
8. Panel injection
8.1 Type of gas used
8.2 Volume of gas per
discharge
8.3 Number of cylinders (2 100%)
8.4 Duration of discharge
8.5 Volume required tomaintainconcentration for
required period
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
12/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
ItemNo.
Description No. ofUnitsandlocation
Approx.oilcontentof eachunit(litres)
Oilconditions(press./temp. &flash point(bar/oC)
Envelopedimensions& areataken(m & m2)
Type ofdetectorsystem
NumberofDetectorsper unit
Numberandtype ofnozzlesper unit
Minimumpressureat eachnozzle(bar)
Nozzledischargerate atmin.pressure(l/s)
TheoreticalWaterquantityper unit(l/s)
Installedwaterquantityper unit(l/s)
9. Automaticwater spraydelugeprotection
9.1 Generator
transformers9.2 Unittransformers
9.3 Othertransformers
9.4 11 kV/415Vauxiliarytransformers
9.5 Cable floors(list allareas)
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
13/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
Item
No.
Description No. of
Units andlocation
Envelope
dimensions& area taken(m & m2)
Type of
detectorsystem
Number of
Detectorsper unit
Number
and typeof nozzlesper unit
Minimum
pressure ateachnozzle(bar)
Nozzle
dischargerate atmin.pressure(l/s)
Theoretical
Waterquantityper unit(l/s)
Installed
waterquantityper unit(l/s)
10. Automatic wetpipe sprinklersystems
10.1 Store buildings
10.2 Others, if any:
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
14/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
ItemNo.
Description No. ofUnits/Zones
Approx.oilcontentof eachunit(litres)
Oilconditions(press./temp. &flash point(bar/oC)
Envelopedimensions& area taken(m & m2)
Type ofdetectorsystem
Number ofDetectorsper unit
Numberand typeofnozzlesper unit
Minimumpressureat eachnozzle(bar)
Dischargerate ofprojectorat min.pressure(l/s)
TheoreticalWaterquantity perunit(l/s)
Installedwaterquantityper unit(l/s)
11. Automaticfoam/watersprayprotectionsystems
11.1 Balancedpressure
proportioningsystems:
11.1.1 Gas oil pumphouse
11.1.2 Others (list):
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
15/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
ItemNo.
Description No. ofzones/unitsandlocation
Approx.oilcontentof eachunit(litres)
Oilconditions(press./temp. &flash point(bar/oC)
Envelopedimensions& area taken(m & m2)
Type ofdetectorsystem
Number ofDetectorsper unit
Numberand typeofnozzlesper unit
Minimumpressureat eachnozzle(bar)
Dischargerate ofprojectorat min.pressure(l/s)
TheoreticalWaterquantity perunit(l/s)
Installedwaterquantityper unit(l/s)
20. Automaticfoam/watersprayprotectionsystems(cont)
11.2 Diaphragm
pressureproportioningsystems:
11.2.1 Emergencydieselgeneratorsand daytanks
11.2.2 GT arealub.oil tanks
& pipes
11.2.3 GT Lub. oilsystem
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
16/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
ItemNo.
Description No. ofzones/unitsandlocation
Approx.oilcontentof eachunit(litres)
Oilconditions(press./temp. &flash point(bar/oC)
Envelopedimensions& area taken(m & m2)
Type ofdetectorsystem
Number ofDetectorsper unit
Numberand typeofnozzlesper unit
Minimumpressureat eachnozzle(bar)
Dischargerate ofprojectorat min.pressure(l/s)
TheoreticalWaterquantity perunit(l/s)
Installedwaterquantityper unit(l/s)
11.2.4 GeneratorHydrogenseal oilsystem
11.2.5 GasConditioningBuilding
Others(List):
7/30/2019 6M.7 FIRE FIGHTING AND DETECTION SYSTEM.docx
17/17
6M. MECHANICAL TECHNICAL DATA SHEET
6M.7FIRE FIGHTING AND DETECTION SYSTEM
This document contains proprietary information of ISOLUX INGENIERIA S.A. and is to be used solely for the Project and the purpose for which it is furnished. It may not be disclosed to others for a different use without
the written permission of ISOLUX INGENIERIA S.A
MINISTRY OF ELECTRICITY
AND WATER
ISOLUX INGENIER A, S.A.
Itemno.
Description Room/areadimensions
LxWxH
metres
Storagerack
dimensions
metres
Envelopedvolume
m3
Size & No. ofCylinderslitres/No.
Gasstorage
capacity anddischargeduration
litres/secs
Gas designConcentration
%
Quantity typeand
manufacturerof
nozzles
Nozzledischarge rate
at min.pressure
ltr/sec
Typeand
numberof
detectorsystems
12. Gas extinguishingsystems
Areas protected tobe listed by
Contractor :
12.1 Areas with totalroom flooding(unmanned areas)
12.2 Areas with panelinjection (mannedareas)