7 ELEVEN SERVICE STATION354 FLUSHCOMBE ROAD
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
DRAWING LIST
EZ
A3NTS @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
D01
BLACKTOWN, NSW
SITE SPECIFICDRAWINGS
Dwg.No. DRAWING TITLENOTESD01 DRAWING LISTD02 GENERAL NOTESARCHITECTURALA01 SITE PLAN EXISTING CONDITIONSA02 DEMOLITION LAYOUTA03 PROPOSED SITE PLANA04 TANKER PATH LAYOUTA05 EROSION AND SEDIMENT CONTROL PLANA06 ASSET LOCATION PLANFUEL SYSTEMT01 FUEL SYSTEM LAYOUTELECTRICALE01 ELECTRICAL CONDUIT LAYOUTHAZARDOUSHZ01 HAZARDOUS AREA LAYOUTHZ02 HAZARDOUS AREA ELEVATIONSHZ03 HAZARDOUS ZONES TABLEDRAINAGE & CONCRETEH01 SITE DRAINAGE PLANC01 CONCRETE REPLACEMENT PLAN 0 INITIAL HAZKEM ISSUEEZ02.12.20
- ---- ---
5 FUEL SYSTEM LINEWORK
IN-GROUND REMOTE FILL POINTS6
7 DIP POINTS
10
11 FORECOURT
PUMPS/DISPENSERS
NOTES
GENERAL1
2 TANK PIT - EXCAVATION
TANK FITTINGS - TANK REPLACEMENT/NEW INSTALLATION4
TANK INSTALLATION3
MONITORING SYSTEMS9
VENTS. NEW VENT STACK. REFER STANDARD DRAWING GEN17-T005 FOR DETAILS.. FREE FLOW VENT CAPS TO BE INSTALLED UNO.. VENT STACK TO BE PAINTED TO 7ELEVEN PAINT SPECIFICATION.. VENT TERMINATION TO BE ISOLATABLE VIA EXTRACTOR IF DIRECT BURIED.. VENT RISERS TO BE DENSO WRAPPED.
. ALL PUMPS/DISPENSERS TO HAVE CONTAINMENT SUMPS FITTED.REFER STANDARD DRAWINGS FOR DETAILS.. WHERE ISLANDS ARE REQUIRED, CONSTRUCT IN ACCORDANCEWITH 7ELEVEN STANDARD.. SUPPLY AND INSTALL INVERTED "U" BOLLARDS WHERE SHOWN.. SHEAR VALVE TO PRESSURE PIPE CONNECTION TO BE VIATITEFLEX LINE.REFER STANDARD DRAWING GEN17-T008-3 FOR DETAILS.. EXPOSURE OF CANOPY FOOTINGS MAY REVEAL FOOTING ASBEING TOO HIGH. 7ELEVEN IS TO ORGANISE A STRUCTURALENGINEER TO INSPECT AND ADVISE REGARDING SUMPINSTALLATION.. DISPENSERS ARE TO BE INSTALLED & COMMISSIONED BYDISPENSER SUPPLIERS.
. PAVEMENT THICKNESS, JOINTING, COLOUR AND FINISH IS TOBE IN ACCORDANCE WITH SITE CIVIL DRAWING.. CONTRACTOR IS TO PROVIDE ALL LINE MARKING AS SHOWNON DRAWINGS.. FILL POINT PAVEMENT LIDS TO BE ELEVATED TO PROMOTEWATER RUNOFF.. FILL LINES TO BE TAGGED AT BOTH ENDS PRIOR TO BACKFILLING.. SPILL CONTAINERS TO BE WATER TESTED AGAINST RISERS TOENSURE NO LEAKAGE.. SPILL CONTAINERS ARE TO BE LEFT CLEAN AND DRY.. CONTRACTOR TO HOARD/SECURE SITE FOR DURATION OFWORKS. CONTRACTOR TO INSTALL TEMPORARY FENCING AROUND SITEBOUNDARIES.
. GVR-TLS-450PLUS TO BE INSTALLED UNO.
. AUTOMATIC TANK GAUGE PROBES ARE TO BE FITTED TO ALL TANKCOMPARTMENTS. REFER STANDARD DRAWING GEN17-T010. CONTRACTOR IS TO CONFIRM LOCATION OF PROBES IN TANKSWITH THE CONSTRUCTION MANAGER PRIOR TO INSTALLATION.. PRESSURE LINE LEAK DETECTION IS TO BE INSTALLED IN ALLPRESSURE PRODUCT DELIVERY SYSTEMS.. CONDUITS AND CABLES ARE TO BE INSTALLED AS NOTED ONSTANDARD DRAWINGS. REFER TO SITE ELECTRICAL DRAWING FORAPPROXIMATE LOCATIONS OF EQUIPMENT AND CONDUIT PATHS.. WHERE POSSIBLE, PROBES ARE TO BE INSTALLED IN TANK SUMPS.. PROBE, CONSOLE, SENSOR & CABLING INSTALLATION,PROGRAMMING, TESTING COMMISSIONING AND TRAINING TO BECONDUCTED BY CERTIFIED AND ENDORSED CONTRACTORS.SYSTEM MUST BE FULLY OPERATIONAL FOR PRODUCT TO BESAFELY STORED. COMMISSIONING CHECK SHEETS MUST BEPRESENTED TO CM AND STAFF TRAINED.
. DEWATERING & TEMPORARY SHORING MAY BE REQUIRED DURING TANKEXCAVATION/INSTALLATION. REFER TO GEOTECHNICAL REPORT FORSHORING AND ADDITIONAL GEOTECHNICAL PROTECTIVE MEASURES TOBE ADOPTED.. SHORING WILL BE REQUIRED, REGARDLESS OF GEOTECHNICALRECOMMENDATIONS, WHERE EXCAVATION ENCROACHES INTOADJOINING PROPERTIES OR MAY INTERFERE WITH EXISTING FOOTINGSOR FOUNDATIONS.. SHORING IS TO BE DESIGNED AT CONTRACTOR'S COST BY ACHARTERED CIVIL ENGINEER AND SUBMITTED TO THE CONSTRUCTIONMANAGER FOR APPROVAL PRIOR TO COMMENCEMENT OF EARTHWORKS.IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE ALL EXISTINGSERVICES PRIOR TO EXCAVATION.. PROTECTION OF ALL SERVICES & COUNCIL PROPERTY IS THERESPONSIBILITY OF THE CONTRACTOR. ALL DAMAGE TO OFF-SITEPROPERTY CAUSED BY THE CONSTRUCTION SHALL BE MADE GOOD BYTHE CONTRACTOR AT THE CONTRACTOR'S EXPENSE.. FINAL LOCATION OF TRENCHING FOR FUEL SYSTEM PIPEWORK ANDELECTRICAL SYSTEM CONDUITS IS TO BE APPROVED BY THECONSTRUCTION MANAGER. TRENCHING TO BE RATIONALISED AS MUCHAS PRACTICABLE.. CONTRACTOR TO ALLOW TO BATTER OR STEP EXCAVATION UNLESSGEOTECHNICAL RECOMMENDATION CALLS FOR A SHORED EXCAVATION.. EXCAVATED MATERIALS REMOVED FROM EXISTING EXCAVATIONSCANNOT BE RE-USED AS FILL MATERIAL.. FILL EXCAVATIONS ARE TO BE BACKFILLED WITH APPROVED IMPORTEDBACKFILL MATERIAL AS PER TANK MANUFACTURER INSTALLATIONPROCEDURES.. GEOTEX FABRIC IS TO BE USED TO LINE THE TANK EXCAVATION.NOTE : STORAGE TANK BACKFILL MATERIAL SHALL BE IN ACCORDANCEWITH TANK MANUFACTURER SPECIFICATIONS.
. MINIMUM TANK BURIAL DEPTH TO BE 900 mm.
. MINIMUM CLEARANCE TANK TO BOUNDARIES IS 2000 mm UNO.
. IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE ALL EXISTINGSERVICES PRIOR TO EXCAVATION.. REFER TO STANDARD DRAWING GEN17-T003 FOR TANK EXCAVATIONCLEARANCES FOR SHORED AND NON-SHORED INSTALLATIONS.. PROPERTY DAMAGE CAUSED BY THE CONSTRUCTION SHALL BE MADEGOOD. INSTALLATION CONTRACTOR IS TO OBTAIN TANK MANUFACTURER'SAPPROVAL OF BACKFILL MATERIAL AND MATERIAL GRADING CHART.. TANK PRIMARY AND SECONDARY SPACE INTEGRITY IS TO BE PROVENPRIOR TO INSTALLATION, IN ACCORDANCE WITH THE SPECIFICATION.. INSTALLATION CONTRACTOR IS TO PROVIDE SUITABLE AND ADEQUATETANK INSTALLATION AND INSTALLATION SAFETY PROCEDURES IN THE SITESAFETY MANAGEMENT PLAN, AND SHALL PROVE SUFFICIENTCOMMUNICATION OF THESE TO THE SITE STAFF.. ALL TANKS ARE TO BE HELD DOWN TO MANUFACTURER'SSPECIFICATIONS.. TOP OF EXCAVATION BATTER IS SHOWN DIAGRAMMATIC ONLY. REFERSTANDARD DRAWING GEN17-T003 AND SITE SPECIFIC DRAWINGS FORFINAL NUMBER AND LOCATIONS OF WELLS.. NO SERVICES ARE PERMITTED TO CROSS THE TANK EXCAVATION.
. TANK MANWAY PAVEMENT COVER. REFER STANDARD DRAWINGGEN17-T010-2 FOR DETAILS.. PAVEMENT TO BE RAISED AROUND ALL FORECOURT PENETRATIONS TORESIST WATER INGRESS AND TO PROMOTE SURFACE WATER RUNOFFAWAY FROM PAVEMENT COVERS.. NEW TANK SUMPS AND LIDS TO BE INSTALLED.. CONTRACTOR IS TO PROVIDE CLEAR PERMANENT NOTICE ON TANK SUMPINNER LID "DO NOT ENTER-TRAINED PERSONNEL ONLY".. TANK SUMP AND LID SEAL TO BE WATERTIGHT. SUMPS ARE TO BEWATER TESTED TO CONFIRM.. SUMPS TO HAVE TELEFLEX AND BALL VALVES.
. MINIMUM PIPE GRADE IS 1:100 BACK TOWARDS THE TANKS.
. MINIMUM PIPE COVER TO BE 300mm (UNDER CONCRETE) OR 450mmUNDER LANDSCAPED AREAS.. ALL DIRECT BURIED STEEL FITTINGS ARE TO BE DENSO WRAPPED OROTHERWISE CATHOLICALLY PROTECTED.. FUEL SYSTEM PIPEWORK IS TO PENETRATE AS CLOSE ASPERPENDICULAR TO TANK SUMP WALLS AS POSSIBLE.. ALL PRODUCT LINES ARE TO BE TAGGED AT BOTH ENDS IMMEDIATELYON INSTALLATION TO PERMIT CORRECT EQUIPMENT FIT-OFF.. ALL PRODUCT LINES ARE TO BE TAGGED AT BOTH ENDS IMMEDIATELYON INSTALLATION TO PERMIT CORRECT EQUIPMENT FIT-OFF.. ALL PRODUCT, FILL, VENT,VR LINES ARE TO BE PRECISION TESTED, INISOLATION, IN ACCORDANCE WITH THE SPECIFICATION.. PIPING IS TO BE LAID TO MANUFACTURER'S PROCEDURES AND WITHA MINIMUM NUMBER OF BENDS. ROUTES SHOWN ARE INDICATIVEONLY, USE SHORTEST PRACTICABLE ROUTE TO MINIMISE PIPE LENGTH.. MAX LENGTH OF SINGLE STRAIGHT FILL PIPING RUN IS 12m.. PRODUCT PIPING TERMINATION TO BE DIRECT PIPED. FLANGES &TITEFLEX HOSES ARE NOT TO BE USED.
. SPILL CONTAINMENT BOX TO BE INSTALLED.REFER TO STANDARD DRAWINGS.. FUEL SPILL CONTAINMENT BOX TO BE APPROVED BY 7-ELEVENENGINEER AND TO BE CAPABLE OF CONTAINING A MINIMUM OF 15LITRES OF PRODUCT. FILL POINT PERMANENT PAVEMENT MARKERS ARE TO BE FIXED TO THEPAVEMENT FACING THE TANKER DRIVER.. FILL RISERS AND INTERNAL SPILL CONTAINERS ARE TO BE EARTHED.. VERIFY THE SETTING AND OPERATION OF ALL FILL LINE OVERFILLPROTECTION VALVES IF FITTED. VALVES TO BE SET TO 95% ACTUALTANK CAPACITY.. CHAIN AND TAGS TO BE NOMINATED AROUND ALL RISERS.. FILL LINES TO BE TAGGED AT BOTH ENDS PRIOR TO BACKFILLING. FILL/ SPILL CONTAINMENT SUMPS TO BE TESTED AFTER INSTALLATIONTO ENSURE NO LEAKAGE. DIRECT FILL RISERS TO BE DENSO WRAPPED.
. DIP RISERS ARE TO HAVE LOCKABLE SIDE SEAL CAPS FIXED BY CHAINSAND PRODUCT ID MARKERS FIXED TO THE RISERS BELOW THE ADAPTORS.. PAVEMENT DIP POINT COVERS ARE TO BE PAINTED APPROPRIATE TOPRODUCT AND/OR HAVE PERMANENT PAVEMENT MARKERS FITTED.. DIP RISERS TO BE DENSO WRAPPED.. ADEQUATE CLEARANCE TO BE GIVEN BETWEEN ALL RISERS CAPS ANDUNDERSIDE OF PAVEMENT COVERS. (REFER STANDARD DRAWINGS). RISERS AND CAPS TO BE CLEAR OF PROTECTIVE SURROUND TO PERMITEASY OPENING AND CLOSING OF CAPS.. DIP CAPS TO BE 100mm SCREWED BRASS CAPS.
THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH:7ELEVEN STORES SPECIFICATION " THE DESIGN & INSTALLATION OF UPSS"
8
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
GENERAL NOTES
EZ
A3NTS @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
D02
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
FUELVENT
F L U S H C O M B E R O A D
MY
RT
LE
S
TR
EE
T
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE BOUNDARY
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
SITE B
OUND
ARY
CROSSOVER CROSSOVER
CRO
SSO
VER
COMMERCIAL
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
CARPA
RK
REMOTEFUELFILLBOX
T1P95
(50KL)
T2ABANDONED
(50KL)
T3E10
(50KL)
0
SCALE 1 : 250
2m 2m 4m 6m 8m 10m 12m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
SITE PLAN EXISTING CONDITIONS
EZ
A31:250 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
A01
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
FUELVENT
F L U S H C O M B E R O A D
MY
RT
LE
S
TR
EE
T
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE BOUNDARY
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
SITE B
OUND
ARY
CROSSOVER CROSSOVER
CRO
SSO
VER
COMMERCIAL
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
CARPA
RK
REMOTEFUELFILLBOX
T1P95
(50KL)
T2ABANDONED
(50KL)
T3E10
(50KL)
0
SCALE 1 : 200
2m 2m 4m 6m 8m 10m1m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
DEMOLITION LAYOUT
EZ
A31:200 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
A02
EXISTING VENTSTACK TO BEREMOVED
EXISTINGUNDERGROUNDFUEL STORAGETANKS TO BE
REMOVED
EXISTING FUELFILL BOX TO BEREMOVED
EXISTINGDISPENSERS TOBE REMOVED
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
F L U S H C O M B E R O A D
MY
RT
LE
S
TR
EE
T
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE BOUNDARY
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
SITE B
OUND
ARY
CROSSOVER CROSSOVER
CRO
SSO
VER
COMMERCIAL
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT REMOTE FUEL
FILL BOX
INSTALL 2 NEW90KL
UNDERGROUNDFUEL TANKS
0
SCALE 1 : 200
2m 2m 4m 6m 8m 10m1m
0 INITIAL HAZKEM ISSUEEZ17.11.201- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
PROPOSED SITE PLAN
EZ
A31:200 @A3
HAZ-2698- 1
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
A03
INSTALL 3 NEWDISPENSERS 8 HOSE
PULSE LX SERIES
INSTALL NEWVENT STACK
INSTALL NEWOIL/WATER
SEPARATOR
INSTALLNEW ELEC
PIT
INSTALL NEW SPILLSAFE FILL BOX W/ROLLOVER BUND
INSTALL NEW20KL HOLDING
TANK
INSTALLNEW
GRATED PITINSTALL
NEWBOLLARDS
1.5m NON COMBUSTIBLEMATERIALS EXCLUSION ZONE
6705
1405900
2900
1000
INSTALL NEW FOXDIVERSION VALVE
INSTALL NEWFOX CONTROL
PANEL
INSTALL NEW 9KGDRY CHEMICAL
FIREEXTINGUISHERS
INSTALL NEWEMERGENCY
STOP BUTTON
SITE EQUIPMENT AMENDMENTEZ20.11.20CANOPY FOOTINGTO BE SUPPORTED
INSTALLNEW BINS
INSTALL NEW MAIN ELECTRICAL SWITCHBOARD
INSTALL NEW FUEL SYSTEM SUB BOARD
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
F L U S H C O M B E R O A D
MY
RT
LE
S
TR
EE
T
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE BOUNDARY
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
SITE B
OUND
ARY
CROSSOVER CROSSOVER
CRO
SSO
VER
COMMERCIAL
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT
REMOTE FUELFILL BOX
0 INITIAL HAZKEM ISSUEEZ17.11.201- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
TANKER PATH LAYOUT
EZ
A31:300 @A3
HAZ-2698- 1
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
A04
11700
1600 5400
4200
400
1300 8000
Articulating Angle
Lock to Lock Time: 2500Trailer Width Steering Angle
Tractor TrackTrailer Track
: 25002500:
Tractor Width
17M TRI AXLE TANKER 2500:
mm
28.4:70.0:
6.0:
1580
SITE EQUIPMENT AMENDMENTEZ20.11.20
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
F L U S H C O M B E R O A D
MY
RT
LE
S
TR
EE
T
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE BOUNDARY
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
SITE B
OUND
ARY
CROSSOVER CROSSOVER
CRO
SSO
VER
COMMERCIAL
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
TEMP. CONSTRUCTION ENTRY/EXIT
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT
REMOTE FUELFILL BOX
TREE PROTECTION MEASURES
· TREE PROTECTION FENCING IS TO BE ERECTED DEFINING A 5mRADIUS.
· PROTECTIVE FENCING SHALL COMPRISE CHAIN LINK WIRE AND NOLESS THAN 1.8m HIGH AND ANCHORED DOWN WITH CONCRETEBLOCKS/STIFFUPS IN A NON-INTRUSIVE MANNER.
· THE FENCING MUST BE SIGN POSTED, INCLUDING PROJECTARBORIST DETAILS, TO WARN ALL RELEVANT CONTRACTORS OF TPZAND STATE THE FOLLOWING;"TREE PROTECTION ZONE: ENTRY NOT PERMITTED INTO THE TPZWITHOUT CONSULTING THE PA."
TREE PROTECTION ZONE & FENCING
LEGEND
SEDIMENTATION FENCE
GRAVEL BAG SEDIMENT TRAP
GEOTEXTILE INLET FILTER
TEMP. CONSTRUCTION EXIT
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
EROSION AND SEDIMENT CONTROL PLAN
EZ
A31:300 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
A05
EROSION AND SEDIMENT CONTROL
ES1. ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH:MANAGING URBAN STORMWATER - SOILS AND CONSTRUCTION,MARCH 2004.
ES2. EROSION AND SEDIMENT DEVICES TO BE INSTALLED PRIOR TOCOMMENCEMENT OF WORK.
ES3. MAINTAIN ALL EROSION AND SEDIMENT CONTROL DEVICES INACCORDANCE WITH THE REQUIREMENTS IN THE NOMINATEDDOCUMENTS TO THE SATISFACTION OF THE SUPERVISINGENGINEER.
ES4. PREVENT SITE RUNOFF ENTERING ANY STORMWATER PITS THATWERE NOT PROTECTED BY SATISFACTORY EROSION AND SEDIMENTCONTROL.
ES5. MINIMISE THE AREA OF THE SITE BEING DISTURBED AT ANY ONETIME. MAXIMUM LENGTH OF OPEN EXCAVATION SHOULD NOTEXCEED 40m, WHERE PRACTICAL. 1. PROVIDE SEDIMENT FENCES AT THE DOWNSTREAM END OF ALL
DISTURBED AREAS.2. SURROUND ALL CONSTRUCTION AREAS WITH SEDIMENT F
FENCES.3. SURROUND ALL STOCKPILES WITH SEDIMENT FENCES.4. TURF STRIPS SHALL BE PLACED ON THE DOWN SLOPE SIDE OF
THE SEDIMENT FENCES WHERE THERE IS NO EXISTINGVEGETATION COVER.
ES6. ANY SOIL AND WATER CONTROL MEASURES AFFECTED DURING THEDAYS WORK ARE TO BE REINSTATED AT THE END OF EACHWORKING DAY.
ES7. ALL AVAILABLE TOPSOIL FROM WITHIN THE AREA OF DISTURBANCESHALL BE STOCKPILED FOR THE PURPOSE OF RE-VEGETATION ORREMOVED FROM SITE TO AN APPROVED LANDFILL.
ES8. STOCKPILE OF SOIL MATERIALS SHALL NOT BE PLACED ON NATURESTRIPS, FOOTPATHS, ROADWAYS, KERBS, ACCESS CROSSING ORWITHIN WATER WAYS.
ES9. SOIL AND WATER CONTROL MEASURES MAY BE MODIFIED TO BESTSUIT THE CONDITIONS APPLICABLE TO ANY ONE TIME. ANYMODIFICATION MUST BE IN ACCORDANCE WITH THE NOMINATEDDOCUMENTS OR AS DIRECTED BY THE SUPERVISING ENGINEER.THE SOIL & WATER CONTROL MEASURES SHOWN ON THE PLAN AREINDICATIVE ONLY.
ES10. CLEAN SURFACE WATER FROM UPSTREAM OF ANY WORKING AREAMUST BE CONTROLLED SO THAT IT DOES NOT ENTER THEDISTURBED AREA.
ES11. THE UNDERBODY AND TYRES OF ANY VEHICLES LEAVING THE SITEMUST BE INSPECTED AND CLEANED AS NECESSARY.
ES12. THE EROSION AND SEDIMENT CONTROL WORKS ARE TO BEPROVIDED OR MODIFIED IN THE SEQUENCE SPECIFIED IN THENOMINATED DOCUMENTS.
SEQUENCE OF WORKS
THE INSTALLATION OF SOIL AND WATER MANAGEMENT FEATURE MUST BEINSTALLED IN THE FOLLOWING ORDER -
S1. CONSTRUCT SILT FENCES BELOW SITE AND ACROSS ALL RUNOFFAREAS.
S2. PROVIDE SANDBAG KERB INLET SEDIMENT TRAPS AROUND ANYEXISTING STORMWATER PITS AND WITHIN TABLE DRAINS.
S3. CONSTRUCT DETENTION TANK FOR USE AS A SILTATION BASIN. LIMITOUTFLOW FROM BASIN.
S4. CONSTRUCT MEASURES TO DIVERT UPSTREAM FLOWS AWAY FROMSITE, WHERE POSSIBLE.
S5. DIVERT ALL RUNOFF FROM SITE TO DETENTION TANK/SEDIMENT PONDVIA FENCES, SWALES AND BUNDS.
S6. PROVIDE SANDBAG KERB INLET SEDIMENT TRAPS AROUNDSTORMWATER PITS AS THEY ARE CONSTRUCTED.
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
F L U S H C O M B E R O A D
MY
RT
LE
S
TR
EE
T
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE BOUNDARY
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
SITE B
OUND
ARY
CROSSOVER CROSSOVER
CRO
SSO
VER
COMMERCIAL
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT REMOTE FUEL
FILL BOX
0
SCALE 1 : 200
2m 2m 4m 6m 8m 10m1m
0 INITIAL HAZKEM ISSUEEZ02.12.20-- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
ASSET LOCATION PLAN
EZ
A31:200 @A3
HAZ-2698- 1
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
A06
---
LEGEND:
SERVICES - TELSTRA
SERVICES - JEMENA
SERVICES - SYDNEY WATER
NOTE:ASSETS ARE SHOWN FOR TENDERINGPURPOSES ONLY, ADDITIONALINDEPENDENT CONFIRMATION SHOULD BEMADE PRIOR TO ANY EXCAVATION.
DIP
HYDATG
ATG
ATGDIP
DIP
HYD
ATG
ATGDIP
DIP
1211107 8 9
10 D
OOR
COOL
ROOM
EXIT
OW
OW
SITE B
OUND
ARY
CARPARK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
VR1
23
45
ULP E10
DSL
P98 P95
ULP E10
DSL
P98 P95
ULPF
DSLF
P95F
P98FE10F
VR1
VR1
DSLV
P95V
P98V
E10V
VR2VR2
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
FS
FS FS
FS
GRATEDPIT
REMOTE FUELFILL BOX
TANK SCHEDULETANK-ID TANK-SIZE TANK MANUFACTURER COMPARTMENT-SIZE SUB-PUMP PRODUCT DISPENSER-FEEDS
T190, 000LT DOUBLE WALL
FIBREGLASS TANK50, 000LT RED JACKET 1.5 HP ULP 1,2,3,4,5,6
T2 40, 000LT RED JACKET 1.5 HP E10 1,2,3,4,5,6T3
90, 000LT DOUBLE WALLFIBREGLASS TANK
30, 000LT RED JACKET 1.5 HP P95 3,4T4 30, 000LT RED JACKET 1.5 HP P98 1,2,5,6T5 30, 000LT RED JACKET 1.5 HP DSL 1,2,3,4,5,6
FUEL LINE QUANTITIESPIPE NOM. SIZE PIPE DESCRIPTION PIPE LENGTH (Metres)63.00 mm OD PIPES VENT PRODUCT 92 M63/90 mm OD PIPES VENT VR2 31 M63/75 mm OD PIPES PRESSURE DOUBLE CONTAINMENT 174 M90.00 mm OD PIPES VENT VR1 31 M
110.00 mm OD PIPES FILL 76 M
0
SCALE 1 : 100
1m 1m 2m 3m 4m 5m0.5m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
FUEL SYSTEM LAYOUT
EZ
A31:100 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
T01
LINE QUANTITIES ARE FOR REFERENCE PURPOSES ONLY.
NOTE:OBSERVATION WELLS SHOWN.GROUND WATER MONITORING WELLSLOCATIONS, AS REQUIRED BY AS4897,TO BE DETERMINED BY SITE ENGINEER.
- STP SUPPLIER & CAPACITY TO BE CONFIRMED BY 7-ELEVEN ENGINEER.
*
FUEL SYSTEM NOTES:1. INSTALL OVERFILL PROTECTION TO ALL TANK FILL
LINES.2. INSTALL BOTTOM ANCHORS IN ACCORDANCE
WITH MANUFACTURERS RECOMMENDATIONS3. TANKS ARE TO BE INSTALLED IN ACCORDANCE
WITH AS1940 AND AS 4897 ANDMANUFACTURERS GUIDELINES
4. ALL TANK FILL & DIP POINTS TO HAVE NOMINATEDIDENTIFICATION MARKERS FITTED TO AS 4977
5. ALL PIPING TO FALL MIN 1:100 BACK TO TANKS6. INTERNAL LIDS TO FILL BOX PRODUCT FILL POINTS
TO BE SECURELY LABELLED WITH STANDARDCOLOUR CODED PRODUCT MARKER INDICATORS
7. PLUG UNUSED TANK OPENINGS, CLEARLY COLOURCODE & LABEL ALL PRODUCT LINES AT STP'S,DISPENSERS AND FILL BOX
8. SUPPLY & INSTALL Ø300 LOCK BOXES AT DIPPOINTS, TANK MONITORS, AND EXCAVATIONOBSERVATION WELLS.
9. SUPPLY Ø300 RISER AROUND ALL DIP, ATG,RISERS OUTSIDE TURRETS
LEGENDPRESSURE LINES - 63/75mm O.D.DOUBLE CONTAINED NCPP
VENT LINES - 63mm O.D. SINGLE WALL NCPPVR1 - VAPOUR RECOVERY - 90mm O.D. SINGLE WALL NCPPVR2 - SECONDARY VAPOUR RECOVERY - 63/90mm O.D.SINGLE WALL NCPP. ONLY TO BE CONNECTED WHEREREQUIRED BY STATE/LOCAL LEGISLATION OR COMPANYENGINEER.
FILL LINES - 110mm O.D.SINGLE WALL NCPP
FUTURE SYPHON LINES - 63/75mm O.D. (NOT CONNECTED)DOUBLE CONTAINED NCPP
FS - FUTURE SYPHON LINES - CAPPED OFFATG - AUTOMATIC TANK GAUGEOW - OBSERVATION WELLHYD - HYDROGUARD
VR1 TEE ATBOTTOM
T1
2/14/36/5
T2
T5T3
T4
1405
6705
900
19055
10540
47°
DIP
HYDATG
ATG
ATGDIP
DIP
HYD
ATG
ATGDIP
DIP
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3
10 D
OOR
COOL
ROOM
EXIT
OW
OW
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT
REMOTE FUELFILL BOX
0
SCALE 1 : 150
1.5m 1.5m 3m 4.5m 6m 7.5m.75m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
ELECTRICAL CONDUIT LAYOUT
EZ
A31:150 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
E01
DISPENSERS1X 32NB NUPI CONDUITVMS COMMS1X 32NB NUPI CONDUITDETECTION1X 32NB NUPI CONDUIT
HYD1X 32NB NUPI CONDUIT WITHDRAW WIRE ONLY. IFREQUIRED
OBSERVATION WELL1X 32NB NUPI CONDUITWITH DRAW WIRE ONLY.IF REQUIRED, LOOPED TOTURRET.
TURRET SPARE1X 32NB NUPI CONDUIT.TURRET SUBMERSIBLE1X 32NB NUPI CONDUIT.TURRET LEAK DETECTION1X 32NB NUPI CONDUIT.
ATG1X 32NB NUPI CONDUIT.
WASTE WATER1X 32NB NUPI CONDUITWASTE WATER TANK FOR HIGHLEVEL ALARM
ELECTRICAL PIT
MAIN ELECTRICALSWITCH BOARD
NOTE: OPTIONAL1X 32NB NUPI CONDUITLOOPED BETWEEN TANK TURRETS. REFERSITE ENGINEER FOR CONFIGURATION.
FOX CONTROL PANEL1X 32NB NUPI CONDUITREMOTE FUEL FILL BOX1X 32NB NUPI CONDUITFOX DIVERSION VALVE1X 32NB NUPI CONDUIT
VENT1X 32NB NUPI CONDUIT.
3x 110nb CONDUIT
FUEL SYSTEMSUB BOARD
WASTE WATER1X 32NB NUPI CONDUITWASTE WATER TANK FOR HIGHLEVEL ALARM
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3DP 748715
10 D
OOR
COOL
ROOM
EXIT
CANOPY OVER
CONVENIENCE STORE
SITE B
OUNDARY
SITE B
OUND
ARY
COMMERCIAL /CARPARK
CARPARK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT
REMOTE FUELFILL BOX
ZONE 1WITHIN 1.5 METRES OFEND OF VENT PIPES INALL DIRECTIONS.ZONE 2VOLUME BENEATH THISZONE.
ZONE 0INSIDE TANK (TYP)ZONE 1TANK TURRET (TYP)ZONE 2WITHIN 4 METRES OF DIPPOINTS & UP TO1 METRESABOVE THE GROUND
0
SCALE 1 : 150
1.5m 1.5m 3m 4.5m 6m 7.5m.75m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
HAZARDOUS AREA LAYOUT
EZ
A31:150 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
HZ01
ZONE 2WITHIN 0.5 METRES ABOVEAND 1.5 METRES LATERALLYFROM ANY LPG CYLINDER CAGE.
ZONE 2WITHIN 4 METRES OFFILL POINTS & UP TO 1METRES ABOVE THEGROUND.
ZONE 1ENTIRE DISPENSER SUMPZONE 20.5 METRE AROUND PETROL DISPENSER x1.2 METRES HIGH.ZONE 11 METRE AROUND PETROL DISPENSER x0.25 METRES HIGH.ZONE 2AROUND PETROL DISPENSERS MIN 4METRES OR 1 METRE PAST EXTENT OFHOSE /NOZZLE WHICHEVER IS GREATER x0.5 METRES HIGH.
ZONE 2WITHIN 0.5 METRES OF DRAIN &UP TO 0.3 METRES ABOVE THEGROUND.
ZONE 1TANK MANWAY.ZONE 20.5 METRES AROUNDACCESS MANWAY x 0.3METRES HIGH.
ZONE 1WITHIN 1METRE LIQUIDCONNECTIONS AND TOGROUND LEVEL.ZONE 2FUEL TANKERWITHIN 4 METRES OFCONNECTION POINTS &UP TO 0.5 METRESABOVE THE GROUND.TANKER DISCHARGEWITH OR WITHOUTVAPOUR RECOVERY.
ZONE 1WITHIN 0.5METRES FROMCOAMINGS. (Assume hatchesare closed).ZONE 2FUEL TANKERWITHIN 1METRE AROUNDVAPOUR CONNECTIONS ANDDOWN TO GROUND LEVEL.TANKER DISCHARGE WITHOR WITHOUT VAPOURRECOVERY.
NOTE:1. HAZARDOUS AREAS SHOWN AREDEPENDANT ON ADEQUATE VENTILATIONWITHIN THE ROOM OR AREA.
2. THIS DRAWING HAS BEEN PRODUCEDBY PERSONS WITH APPROPRIATEKNOWLEDGE & ACCREDITED WITHUEENEEM052A "CLASSIFYING HAZARDOUSAREAS".
3. ELECTRICAL EQUIPMENT WITHINHAZARDOUS AREA ON SITE TO MEET THEFOLLOWING:
TEMPERATURE CLASS T3 GAS GROUP IIa
ZONE 2
LEGEND:
ZONE 0
ZONE 1
HAZARDOUS AREAS AREAS DESCRIBED INAS/NZS 60079.10.1 - 2009EXPLOSIVE ATMOSPHERES -CLASSIFICATION OF AREAS -EXPLOSIVE GAS ATMOSPHERESPART ZA.4 VEHICLES & FUELDISPENSINGPART ZA.5 FLAMMABLE LIQUIDSPART ZA.6 FLAMMABLE GASES
EPL-Ga,Gb,Gc
EPL-Ga,Gb
EPL-Ga
ZONE 1ULLAGE INSIDE OILWATER SEPARATOR .ZONE 2AREA WITHIN 0.5MABOVE THE UNIT &2.0M LATERALLYEXTENDING DOWN TOTHE GROUND LEVEL.
CONNECTIONS/COUPLINGPOINTS
4000 4000
R100
0R500
R1000
ZONE 1
ZONE 1
ZONE 2 ZONE 2 ZONE 2
PAVING LEVEL
PAVING LEVEL TANK TURRETLc
PAVING LEVEL
50
0
500
1000
25
0 4000 MIN.
1000
12
00
MIN
.
R1500
R1500
MAXIMUMEXTENTOF HOSE
FIGURE 4HAZARDOUS ZONE INSIDE
FUEL TANK TURRETSAS/NZS 60079.10.1-2009
ZA.5.2.9
FIGURE 3HAZARDOUS ZONE
SURROUNDING FUEL VENT PIPESAS/NZS 60079.10.1-2009
ZA.4.4.2.5 - Fig. ZA.8
FIGURE 5HAZARDOUS ZONE SURROUNDING
ADEQUATELY VENTILATED FUELDISPENSERS/PUMPS
AS/NZS 60079.10.1-2009ZA 4.4.2.2
HYDRAULICCOMPARTMENT
VAPOURBARRIER
ZONE 2
10
00
4000 4000
FIGURE 1HAZARDOUS ZONE SURROUNDING
FUEL FILL POINTSAS/NZS 60079.10.1-2009
ZA.4.4.2.5
PAVING LEVEL
R4000
DIP OR FILL POINTLc
FIGURE 2HAZARDOUS ZONE SURROUNDING
DIP POINTSAS/NZS 60079.10.1-2009
ZA.4.4.2.5
10
00
ZONE 2ZONE 2
ZONE 1
ZONE 1
ZONE 2 ZONE 2
ZONE 1
FIGURE 9HAZARDOUS ZONE SURROUNDING
LPG EXCHANGE CYLINDER CAGE STORAGEFRONT ELEVATION
AS/NZS 60079.10.1-2009ZA.6.5.2.16
50
0
15001500
PAVING LEVEL
PAVING LEVEL
ZONE 2
PAVING LEVEL
FIGURE 6HAZARDOUS ZONE SURROUNDING
ROAD FUEL TANKER DISCHARGE WITHOR WITHOUT VAPOUR RECOVERY
AS/NZS 60079.10.1-2009ZA.5.2.6.3 - Fig. ZA.33
PLATE SEPARATOR
STORAGE VESSEL /HOLDING TANK
PETROLDISPENSER
EFFLUENT COLLECTION PITS INFORECOURT ARES SUSCEPTIBLE TO
PEROL DISPENSER SPILLAGE(E.G.ADJACENT TO PETROL DISPENSER)
ZONE 2
30
0
500
30
0
500
ZONE 2
30
0
30
0
500
50
0
500
FIGURE 9HAZARDOUS ZONE SURROUNDING
COALESCING PLATE SEPARATOR (CPS) -ADEQUATELY VENTILATED AREAS
AS/NZS 60079.10.1-2009ZA.4.5.2 , ZA.4.5.4 & ZA.4.5.1.2
ZONE 2
ZONE 1ZONE 1
OIL/WATER PIPEWORK
ZONE 1ULLAGE
SPACE INTHE
SEPARATOR
0
SCALE 1 : 100
1m 1m 2m 3m 4m 5m0.5m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
HAZARDOUS AREA ELEVATIONS
EZ
A31:100 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
HZ02
NOTE:1. HAZARDOUS AREAS SHOWN AREDEPENDANT ON ADEQUATE VENTILATIONWITHIN THE ROOM OR AREA.
2. THIS DRAWING HAS BEEN PRODUCEDBY PERSONS WITH APPROPRIATEKNOWLEDGE & ACCREDITED WITHUEENEEM052A "CLASSIFYING HAZARDOUSAREAS".
3. ELECTRICAL EQUIPMENT WITHINHAZARDOUS AREA ON SITE TO MEET THEFOLLOWING:
TEMPERATURE CLASS T3 GAS GROUP IIa
ZONE 2
LEGEND:
ZONE 0
ZONE 1
HAZARDOUS AREAS AREAS DESCRIBED INAS/NZS 60079.10.1 - 2009EXPLOSIVE ATMOSPHERES -CLASSIFICATION OF AREAS -EXPLOSIVE GAS ATMOSPHERESPART ZA.4 VEHICLES & FUELDISPENSINGPART ZA.5 FLAMMABLE LIQUIDSPART ZA.6 FLAMMABLE GASES
EPL-Ga,Gb,Gc
EPL-Ga,Gb
EPL-Ga
NOTES:
1. THIS DETERMINATION IS BASED ONAS60079.10.1:2009 - CLASSIFICATION OFAREAS - EXPLOSIVE GAS ATMOSPHERES.
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
HAZARDOUS ZONES TABLE
EZ
A3NTS @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
HZ03
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3
10 D
OOR
COOL
ROOM
EXIT
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
COMMERCIAL /
CARPARK
CARPA
RK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT
REMOTE FUELFILL BOX
INSTALL NEW FOXDIVERSION VALVE
CONNECT FOX VALVE TOSTORM WATER LEGALPOINT OF DISCHARGE
110Ø UPP DRAINPIPE FROM UNDERCANOPY DRAIN PITSTO HOLDING TANKS
0
SCALE 1 : 150
1.5m 1.5m 3m 4.5m 6m 7.5m.75m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
SITE DRAINAGE PLAN
EZ
A31:150 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
H01
INSTALL NEWROLLOVER BUND
INSTALL WATER PIPE LINETO FOX CONTROL PANEL
DRAINAGE NOTES:1. WHEN HOLDING TANK FITTED,
INSTALL HIGH LEVEL ALARM SET AT ALEVEL WHICH STILL ALLOWS A FULLDELIVERY TANKER COMPARTMENT INTANK.HIGH HIGH LEVEL SET AT 90% TANKCAPACITY. INDICATOR LIGHTS TO BEINSTALLED INSIDE CONSOLE AREA.
2. PROVISION SHALL BE MADE FORFUTURE FIT OUT OF AN OILSET-1000HYDROCARBON ALARM WITHIN THEHOLDING TANK / SQID.
LEGEND:
OIL / WATER DRAIN LINE
STORMWATER DRAIN LINE
1
2
3
4
5
13
14
15
16
17
18
1211107
6
8 9
LOT 3
10 D
OOR
COOL
ROOM
EXIT
CANOPY OVER
CONVENIENCE STORE
SITE BOUNDARY
SITE B
OUNDARY
SITE B
OUND
ARY
CARPARK
CARPA
RK
CARPA
RK
FUELVENTS
GRATEDPIT
20KLHOLDING
TANK
OIL/WATERSEPARATOR
FOXCONTROL
PANEL
GRATEDPIT
GRATEDPIT
GRATEDPIT
ELECPIT
GRATEDPIT
REMOTE FUELFILL BOX
175mm THICK CONCRETE 331.77m²
200mm THICK CONCRETE 179.5m²
AREA TO BE LANDSCAPED 0m²
0
SCALE 1 : 150
1.5m 1.5m 3m 4.5m 6m 7.5m.75m
0 INITIAL HAZKEM ISSUEEZ02.12.20- ---- ---
A.B.N. 48 005 299 427
VICTORIA 3149 AUSTRALIA357 FERNTREE GULLY ROAD MOUNT WAVERLEY
TELEPHONE (03) 9541 0711 FAX (03) 9541 0782INCORPORATED IN VICTORIA
PTY LTD7-ELEVEN STORES
SCALESIZE
SHEET REVISION NO.
APPROVEDAMENDMENTBYDATENO.
DRAWING No.
CHECKED BY
DRAWN BY
DATE CREATED
DATE PLOTTED
APPROVAL FOR ISSUE
........................
PROJECT
TITLE
SHEET
HAZKEM
CONCRETE REPLACEMENT PLAN
EZ
A31:150 @A3
HAZ-2698- 0
-354 FLUSHCOMBE ROAD
BLACKTOWN, NSW
17.11.20 7 ELEVEN SERVICE STATION
INFORMATION ISSUE
C01