MATERIAL REQUISITION (TOP SHEET)
ITEM: MISCELLANEOUS
FLANGES
Issue Status1. -> Entire Requisition Issued
2. -> Only Revised Pages are Issued
(Fill 1 or 2 from below in this bracket)
DOCUMENT NUMBER
(Always quote this document number given below as reference)
1208 000 WC 3321MR 05/02/2013 16/430
JOB NO. UNIT/
AREA
COST
CENTRE
DOC
CODESR.NO. REV DATE
ORIGINATING
DIVN./DEPT
VENDOR NAMEVENDOR CODE
Material to be delivered at (job site) BCPL, DULIAJAN within the delivery period specified in the "Request For Quotation"
(RFQ).
Notes :
This page is a record of all the Revisions of this Requisition.
The nature of the Revision is briefly stated in the "Details" column below, the Requisition in its entirety shall be
considered for contractual purposes.
When a Requisition is revised, only the revised pages may be issued.
When revised pages only are issued, the revised pages shall form part of the original Requisition. The original
requisition alongwith the revised pages shall be considered in its entirety for contractual purposes.
REV. DATE BY CHK. APPD.
A 05/02/2013 ISSUED FOR BIDS
DETAILS
[ ]
Vendors are required to quote strictly as per technical specifications / notes stipulated in the material requisition. The
offers with deviations are likely to be summarily rejected.
1.
2.
3.
4.
5.
MR Category :I
MSM SB AKG
This is a system generated approved document and does not require signature
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 2/33
e s i g n i t c o v e r s a r e p r o p e
r t y o f E N G I N E E R S I N D I A L I M I T E D .
T h e y a r e m e r e l y l o a n e d o n
t h e b o r r o w e r ' s e x p r e s s a g r e e m e n t t h a t i t w i l l n o t b e r e p r o d u c e d , c o p i e d , e x h i b i t e d n o r u s e d
d w a y a n d p r i v a t e u s e p e
r m i t t e d b y w r i t t e n c o n s e n t g i v e n
b y t h e l e n d e r t o t h e b o r r o w e r f o r t h e i n t e n d e d u s e .
E I L - 1 6 4 1 - 5 1 5 R
e v . 0
A 4 - 2 1 0 x 2 9 7
x 2 7 9
LIST OF ATTACHMENT
DOCUMENT TITLESR. NO DOCUMENT NO.REVISION
NO. DATE
1
2
3
4
TECHNICAL NOTES FOR
FLANGES,SPECTACLE BLINDS ANDDRIP RINGS
INSPECTION AND TEST PLAN FOR FLANGES, SPECTACLE BLINDS ANDDRIP RINGS
SPECIFICATION FOR DOCUMENTATIONREQUIREMENTS FROM SUPPLIERS
ADDITIONAL TECHNICALREQUIREMENTS FOR FLANGE
6-44-0053
6-81-0006
6-78-0003
6907-000-ATR-4004
4
3
0
B
04/07/2008
15/07/2011
04/06/2009
27/11/2012
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 3/33
e s i g n i t c o v e r s a r e p r o p e
r t y o f E N G I N E E R S I N D I A L I M I T E D .
T h e y a r e m e r e l y l o a n e d o n
t h e b o r r o w e r ' s e x p r e s s a g r e e m e n t t h a t i t w i l l n o t b e r e p r o d u c e d , c o p i e d , e x h i b i t e d n o r u s e d
d w a y a n d p r i v a t e u s e p e r m i t t e d b y w r i t t e n c o n s e n t g i v e n
b y t h e l e n d e r t o t h e b o r r o w e r f o r t h e i n t e n d e d u s e .
E I L - 1 6 4 1 - 5 1 5 R
e v . 0
A 4 - 2 1 0 x 2 9 7
x 2 7 9
MR ATTACHMENT
SR.NO. DETAIL DESCRIPTION QTY. U. RATE TOT.VALUE CDD
FLNG.WN, B-16.47-A, ASTM A 105, 150, RF/125AARH
FLNG.WN, B-16.5, ASTM A 105, 600, RTJ/63AARH
Item Description:
Item Description:
FWA0127Z02518ZZZZ
FWC0169Z01806ZZZZ
26.0 INCH, STD
12.0 INCH, S80
4 NOS
4 NOS
1
2
ITEMCODE
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 23/33
01 ei
$fg ar fafieuI 6 .71 eiram, 0311 111-41
ENGINEERSINDIA LIMITEDIA Goo of India Under taking)
INSPECTION AND TEST PLANFOR
FLANGES, SPECTACLE BLINDS & DRIP RINGS
STANDARD SPECIFICATION No.
6-81-0006 Rev. 3
Page 1 of 6
4 c r ^ c o o ftr
f t t a T ur i<Er r
INSPECTION AND TEST PLAN
FOR
FLANGES, SPECTACLE BLINDS & DRIP RINGS
A s L 4 ' 0
3 15.07.2011 REVISED AND RE-ISSUED TKK CG AK C DM
2 30.06.2010 REVISED AND RE-ISSUEDRK B VK J SKP ND
1 28.09.2007 REVISED AND RE-ISSUED PD RB MVKK VC
0 23.04.2002 ISSUED FOR IMPLEMENTATION NKN SPS AKB SB
Rev.No .
Date PurposePrepared
byChecked
by
Standards Committee
Convenor
Standards Bureau
Chairman
Approved by
Format No. 8-00-0001-F7 Rev. 0 Copyright EIL — All rights reserved
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 24/33
q -AINSPECTION ENGINEERS
AND TEST PLAN STANDARD SPECIFICATION No.
FO R 6-81-0006 Rev. 3
BLINDS & DRIP RINGS Page 2 o f 6
51grr 051-aG14.2R eirove fet dedrel
INDIA LIMITED10 Govt of India Undertaking)
FLANGES, SPECTACLE
Abbreviations:
CCE or CCOE Chief Controller of ExplosivesMPT/MT Magnetic Particle Testing
CEIL Certification Engineers International Limited MR T Mechanical Run Test
CIMFR Central Institute of Mining & Fuel Research MT C Material Test Certificate
CE Carbon Equivalent NPSH Net Positive Suction Head
DF T Dry Film Thickness NDT Non Destructive Testing
DT Destructive Testing PO Purchase Order
DP T Dye Penetrate Testing PESO Petroleum Explosive Safety Organization
DH T De-hydrogen Heat Treatment PQ R Procedure Qualification Record
E R T L Electronics Regional Test Laboratory PR Purchase Requisition
FCRI Fluid Control Research Institute PM I Positive Material Identification
HT Heat Treatment RT Radiography Testing
HIC Hydrogen Induced Cracking SSCC Sulphide Stress Corrosion Cracking
IT P Inspection and Test Plan T C Test CertificateIP Ingress Protection TPI or TPIA Third Party Inspection Agency
IHT Intermediate Heat Treatment UT Ultrasonic Testing
ISR Intermediate Stress Relieving VDR Vendor Data Requirement
IC Inspection Certification WPS Welding Procedure Specification
IGC Inter Granular Corrosion WPQ Welders Performance Qualification
L PT Liquid Penetrate Testing
Inspection Standards Committee
Convenor Mr. A.K. Chaudhary
Members:
Mr. SS Lotay Mr. Rajeev Kumar Mr. G. Poornachandra Rao
Mr. S.C. Gupta Mr. Anoop Goel Mr. MP Jain (Project)
Mr. R.K. Singh Mr. G. Suresh
Format No. 8-00-0001-F7 Rev. 0 Copyright EIL — All r ights reserved
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 25/33
STANDARD S PECIF ICATION No.
6-81-0006 Rev. 3
Page 3 o f 6
E N G I N E E R S
Og l aWeg INDIA LIMITEDranee, cleave Wagng ) IA Govt of India Undertaking)
INSPECTION AND TEST PLAN
FOR
FLANGES, SPECTACLE BLINDS & DRIP RINGS
1.0 SCOPE
This Inspection Test Plan covers the minimum testing requirements of Flanges, Spectacle Blinds & Drip Rings.
2.0 REFERENCE DOCUMENTS
PO/PR/Standards referred therein/ Job specifications /Approved documents.
3.0 INSPECTION AND TEST REQUIREMENTS
SL
NO.STAGE/ ACTIVITY CHARACTERISTICS
QUANTUM OF
CHECKRECORD
SCOPE OF INSPECTION
SUB
SUPPLIER
SUPPLIER EIL/TPIA
1.0 Procedure
1. 1Heat Treatment, NDT
and Other ProceduresDocumented Procedures 100%
Procedure
Documents- H R
1 .2 WPS,PQR & WPQWelding Parameters &
Qualification Record100%
WPS,PQR
&WPQ- H
W- New
R- Existing
2.0 Material Inspection
2. 1 Raw Material InspectionChemical & Mechanical
Properties100% Test Certificates - H R
Copyright EIL — All r ights reservedormat No. 8-00-0001-F7 Rev. 0
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 26/33
fi r v-folvez. )
ENGINEERS
INDIA LIMITEDIA Goof of IndiA LindeFlaking)
INSPECTION AND TEST PLAN
FOR
FLANGES, SPECTACLE BLINDS & DRIP RINGS
STANDARD SPECIFICATION No.
6-81-0006 Rev. 3
Page 4 of 6
SL
NO.STAGE/ ACTIVITY CHARACTERISTICS
QUANTUM OF
CHECKRECORD
SCOPE OF INSPECTION
SUB
SUPPLIER SUPPLIER EIL/TPIA
3.0 In Process Inspection
3.1 Welding / ForgingForging /Welding
Parameters100%
Inspection
Reports- H R
3.2
Ferrite Check of SS
Welds in Spectacle Blinds
(If Applicable)
% Ferrite CheckRandom Inspection Report
- H R
3.3Heat Treatment
Stress Relieving,
Normalising, Tempering,
Solution Annealing,
Stabilization Heat
Treatment etc. as
applicable
100% HT chart - H R
3. 4Identification of Test
Samples
Product Chemical,
Mechanical, Impact, IGC
and Other test as applicable
PR / Purchase
SpecificationTest Reports - H H
3.5 Product Analysis Chemical CompositionPR / Purchase
SpecificationTest Reports - H R
3.6Destructive Testing Mechanical, Impact, IGC
and Other test as applicable
PR / Purchase
Specification Test Reports - H H
3. 7
UT / LPT / MPT As
applicableSurface & Internal
ImperfectionsPR / PurchaseSpecification
Test Reprts - H R
Format No. 8-00-0001-F7 Rev. 0 Copyright EIL — All r ights reserved
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 27/33
arael
Iamn eieen‘rn,"70,011
ENGINEERS
INDIA LIMITEDIA Goer of India Undertaking)
INSPECTION AND TEST PLAN
FOR
FLANGES, SPECTACLE BLINDS & DRIP RINGS
STANDARD S PECIF ICATION No.
6-81-0006 Rev. 3
Page 5 of 6
SL
NO.
STAGE/ ACTIVITY CHARACTERISTICSQUANTUM OF
CHECK
RECORD
SCOPE OF INSPECTION
SUBSUPPLIER SUPPLIER EIL/TPIA
3.8Galvanizing
(If Applicable)
Integrity Of Galvanised
CoatingRandom
Inspection Report- H R
4.0 Final Inspection •
4.1. Final Inspection
1.Visual
2. Dimensions
3.Hardness
4. Marking etc
100% By Supplier &
At Random by
EIL/TPIA
Inspection Report - H H
4. 2
PMI Check
(As per EIL Spec. 6-81-
0001)
Chemical Check
As Per EIL Spec.
6-81-0001 Inspection report - H W / R
4.3 Final StampingStamping Of Accepted
Items
Stamping of 10%
Items which are
witnessed by
EIL/TPIA. Balance
Items to have
Supplier QC Stamp.
Inspection Report - H H
5.0 Painting
5.1Rust Preventive Coating
& Color Coding
Visual & Color Coding as
applicable100% Inspection Report H R
Format No. 8-00-0001-F7 Rev. 0 Copyright EIL — All r ights reserved
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 28/33
ENGIN
LIMITEDDI.WN ,iecrxe 51370.1)
IA Govt of India Uncle/taking)
INSPECTION AND TEST PLAN
FOR
FLANGES, SPECTACLE BLINDS & DRIP RINGS
STANDAR D SPECIF ICATION No.
6-81-0006 Rev. 3
Page 6 o f 6
SL
NO.STAGE/ ACTIVITY CHARACTERISTICS
QUANTUM OF
CHECKRECORD
SCOPE OF INSPECTION
SUB
SUPPLIER SUPPLIER EIL/TPIA
6.0 Documentation & IC
6.1Documentation &
Inspection Certificate(IC)
Review of Stage Inspection
Reports / Test Reports &
Issue of IC
100% Supplier TC & IC - H H
Legend: H- Hold (Do not proceed without approval), Random -10% (min.1 no.) of each size and type of Bulk item, R-Review, RW- Random Witness, W-Witness
(Gveduenoice workmyproceedafter schedueddate).
NOTES (As applicable):
For Non NACE & Non Hydrogen service Carbon Steel Flanges, Spectacle Blinds & Drip Rings up to size 24"-300ANSI Class Will be accepted on review of
Supplier Test Certificates. Supplier Test Certificate to be reviewed by EIL/TPIA.
Wherever W/ R is indicated, Inspection Engineer shall decide the option to be exercised for particular stage and supplier.
In case of conflict between purchase specification, contract documents and ITP, more stringent conditions shall be applicable.
This document describes generally the requirements pertaining to all types of the item. Requirements specific to PO and the item are only applicable.
Acceptance Norms for all the activities shall be as per PO/PR/STANDARDS referred there in /Job Specification /Approved Documents.
Wherever order is placed on stockiest, the item shall be accepted based on manufacturer's TC conforming compliance with requirements as per material
specification & PR. All hold / witness stages shall be considered as "Review" by TPIA in that case.
Format No. 8-00-0001-F7 Rev. 0 Copyright EIL — All r ights reserved
ADDITIONAL TECHNICAL
DOCUMENT No.
6907-000--ATR-4004
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 29/33
ADDITIONAL TECHNICALREQUIREMENTS
6907-000--ATR-4004Rev.B
Page 1 of 2
ADDITIONAL TECHNICALREQUIREMENTS
(FLANGES)
ADDITIONAL TECHNICAL
DOCUMENT No.
6907-000-ATR-4004
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 30/33
REQUIREMENTS6907 000 ATR 4004
Rev.BPage 2 of 2
ADDITIONAL TECHNICAL REQUIREMENTS(FLANGES)
1. Vendor to note that no correspondence whatsoever shall be entered into or entertained after the bid submission.
2. Vendor shall furnish quotations only for those items, for which he is approved by EILand which he can supply strictly as per MR specifications.
3. No technical details of any nature shall be included in the offer. If the offer contains any technical deviation or clarification or stipulates any technicalspecifications (even if in line with the MR requirements), the offer shall be liablefor rejection. However, For items where the vendor has entered into MOU withEIL,he may state that the offer is as per MOU with EIL.
4. The submission of prices by the vendor shall be construed to mean that he hasconfirmed compliance with all technical specifications of the corresponding item(s).
5. Vendor shall confirm categorical compliance to the following:
a) Additional Technical Requirements, 6907-000-ATR-4004.b) Technical Notes for Flanges, Spectacle Blinds and Drip Rings,
6-44-0053.c) Inspection and Test Plan for Flanges, Spectacle Blinds and Drip Rings,
6-81-0006.d) Specification for documentation requirements from supplier, 6-78-0003.
.
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 31/33
INSTRUCTIONS TO BIDDERS FOR SUBMISSION OF PRICES IN CD
(for PIPING BULK ITEMS)
1. Insert the technical CD (enclosed with RFQ) in the CD drive.
2. Using the windows explorer, go to the folder name ‘REQUISITION’. This
folder contains an excel file named jobno + mr.sr.no. For example, if jobno
is 1111 and mr.sr.no is 3030 then the file will be 11113030.xls.
3. Copy this file to your hard drive.
4. Select the file name and right click on the same. Click on “properties”
option from the Pop Up menu.
5. The system will open the “properties” window for the file as shown below
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 32/33
6. Uncheck the option “read only” as shown above.
7. Click on “OK”.
8.
Now open this excel file using MS Excel.9. Enter the prices in “Unit price” column. In case any item is not to be
quoted, leave the “unit price” column blank.
10. You must not change any other column otherwise the bid shall be liable for
rejection.
11. You must enter the currency in which prices have been quoted.
12. After filling the prices, supplier should save the file and then copy this file
in a new CD at root only.13. This CD must be submitted to EIL along with the priced offer within a sealed
envelope.
7/28/2019 71012_MR
http://slidepdf.com/reader/full/71012mr 33/33
Client: Project:
PR No.
FOA No.
Date of FOA
PO No.
Fax:Phone: Email:
S.No. Equipment Number Drg./Doc. Nomenclature as
per EIL Vendor Data
Requirement
Category
Review (R) /
Records(I)
Scheduled
date of 1st
Submission
(Rev.0)
Form
Electronic
(E)/Print (P)
Remarks
Engineers India Limited
Item Description:
EIL Originating Department : Contact Person (EIL) :
City
Contact Person
Address
Vendor Drg./ Doc. Number Vendor Drg./ Doc. Title
Vendor Drawing/ Document Submission ScheduleStatus
Date
Vendor Name