6
265 1B1 1B1 CODES/STANDARDS USA 265 CODES/STANDARDS-CSA/CMVSS 12D ELECTRICAL SYSTEM 30 AMP 1D5 ENTERTAINMENT CENTR/EXT W/CD NOTES: WIRES ROUTED UNDER FLOOR. SEE LOAD CENTER/ATS FOR ADDITIONAL INFORMATION. 2 1. 3 ROUTE GROUND WIRE FROM LOAD CENTER AND MODULE-ALS THROUGH FLOOR IN THIS AREA AND CONNECT TO GROUND STUD OF FRAME ASM. 5 4. AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION. X-X FOR ELECTRICAL CALLOUTS SEE DWG NO. 121339-01-000 FOR ELECTRICAL TORQUE SPECIFICATIONS SEE DWG NO. 128783-01-000 RCP-2 (BLU) EXT COMPT INVERTER-DC/AC, 1000 WATT 401 WIRE ROUTED THROUGH FLOOR IN THIS AREA. 5 3 (BLU) 7600 DROP THRU RCP-EXT THRU EXT ENT CTR THRU RCP-B (UNDER REFRIG) THRU GFI (REFRIG) TO LOAD CENTER (MAIN) 2300 DROP TO LOAD CENTER (BRN) 3400 DROP TO LOAD CENTER (BRN-2) 9900 DROP THRU RCP-B WARDROBE THRU RCP-BDRM DVD TO 110V CONNECTOR (WHT) 1400 DROP TO RELAY-EMS (RED) 2100 DROP TO LOAD CENTER 1D5 (BLU) PART OF WIRE ASM-CHASSIS TO 110V CONNECTION UNDER SOFA (BLK)(BRN-2) PART OF WIRE ASM-CHASSIS 3 (BRN-2) 2200 LOOP THRU RCP-B BATH TO RIGHT SIDE (WHT) 1100 DROP TO WATER HEATER FROM EMS (BLU) 4200 DROP THRU RCP-BATH TO RCP-B (UNDER LAV SINK) FROM RCP-EXTERIOR (RED) 2200 DROP TO RCP-BLANK COVER-INVERTER 181329-04-CHT SCREW G11-08-12U (11) INVERTER (REF) 110V CONNECTORS (BRN,BRN-2) SCREW G39-06-24U (8) 401 2 401 12D CLAMP 10497-03-000 SCREW G67-10-08B FROM GENERATOR MAIN CLAMP 10497-03-000 SCREW G67-10-08U ATS 2 CLAMP 10497-10-000 SCREW G67-10-12U POWERCORD AA THROW IN WIRE #7 ATS 2 107 116 MAIN ATS POWERCORD ALL WEATHER UPGRADE PACKAGE 078 FROM GENERATOR 2 VIEW AA VIEW AA 078 3 UNSPECIFIED TOLERANCES: MATERIAL: C D 1 TWO-PLACE (X.XX) DSNR: DESCRIPTION: 8 2 B ALL DIMENSIONS ARE IN MILLIMETERS DFTR: 6 A 6 FIRST USED: A REV WHOLE DIM (X) D REF: 8 ITEM/PART NO: 4 WEIGHT: (LBS) SHEET: 7 B 2 4 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES ANGLE 5 5 1 3 COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,110V 1 OF 6 000127426 / 32474701000 3 1.5 0.50 1 CLAMP 10497-03-000 SCREW G67-10-08U 18 E30T 12-Jan-2018
Transcript

2651B1

1B1 CODES/STANDARDS USA

265 CODES/STANDARDS-CSA/CMVSS

12D ELECTRICAL SYSTEM 30 AMP

1D5 ENTERTAINMENT CENTR/EXT W/CD

NOTES:

WIRES ROUTED UNDER FLOOR.

SEE LOAD CENTER/ATS FOR ADDITIONAL INFORMATION.2

1.

3

ROUTE GROUND WIRE FROM LOAD CENTER AND MODULE-ALSTHROUGH FLOOR IN THIS AREA AND CONNECT TOGROUND STUD OF FRAME ASM.

5

4. AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

RCP-2 (BLU)EXT COMPT

INVERTER-DC/AC, 1000 WATT401

WIRE ROUTED THROUGH FLOOR IN THIS AREA.

5 3

(BLU) 7600 DROPTHRU RCP-EXTTHRU EXT ENT CTRTHRU RCP-B (UNDER REFRIG)THRU GFI (REFRIG)TO LOAD CENTER(MAIN) 2300 DROPTO LOAD CENTER(BRN) 3400 DROPTO LOAD CENTER(BRN-2) 9900 DROPTHRU RCP-B WARDROBETHRU RCP-BDRM DVDTO 110V CONNECTOR(WHT) 1400 DROPTO RELAY-EMS(RED) 2100 DROPTO LOAD CENTER

1D5

(BLU)PART OF WIRE ASM-CHASSISTO 110V CONNECTIONUNDER SOFA

(BLK)(BRN-2)PART OF WIREASM-CHASSIS

3(BRN-2) 2200 LOOPTHRU RCP-B BATHTO RIGHT SIDE(WHT) 1100 DROPTO WATER HEATERFROM EMS(BLU) 4200 DROPTHRU RCP-BATHTO RCP-B (UNDER LAV SINK)FROM RCP-EXTERIOR(RED) 2200 DROPTO RCP-BLANK

COVER-INVERTER181329-04-CHTSCREWG11-08-12U (11)

INVERTER(REF)

110V CONNECTORS(BRN,BRN-2)SCREWG39-06-24U (8)

4012 401

12D

CLAMP10497-03-000SCREWG67-10-08B

FROM GENERATOR

MAINCLAMP10497-03-000SCREWG67-10-08U

ATS 2

CLAMP10497-10-000SCREWG67-10-12U

POWERCORD

AA

THROW IN WIRE #7

ATS2

107

116

MAIN

ATS

POWERCORD

ALL WEATHER UPGRADE PACKAGE078

FROM GENERATOR

2

VIEW AA

VIEW AA 078

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,110V

1 OF 6 000127426 / 32474701000

3

1.5

0.50

1

CLAMP10497-03-000SCREWG67-10-08U

18 E30T

12-Jan-2018

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

WIRE ROUTED IN SIDEWALL.1

3.

2651B1FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

1B1 CODES/STANDARDS USA

265 CODES/STANDARDS-CSA/CMVSS

WIRE ROUTED THRU FLOOR IN THIS AREA.2

2

1RCP-2 (BLU)

GALLEY

1

4X4 BOXDETAIL BB

RCP-B (BLU)UNDER LAV

RCP-2 (BLU)BATH WALLSP-06

WHT WIRE TOWATER HEATER

BOX8289-01-000SCREWG11-08-12U (2)COVER8294-01-000WIRE ASM-GROUND133678-01-000CONNECTOR8313-01-000 (3)

(BLK) WIREFROM SIDEWALL

(BLK) FROMWIRE ASM-

CHASSIS

DETAIL BB

CONNECTOR8356-01-000

CONNECTOR8356-02-000

RCP-1 (BLK)MICROWAVE

WIRE ASM-CHASSIS

DETAIL BA

DETAIL BA 21R

SP-061RCP-2 (BLU)GALLEY WALL

RCP-B (RED)BATHWALL-1

RCP-B (BRN-2)BATHWALL-2

RCP-2 (BRN-2)DINETTE

14WSPACER-RCP133713-04-CHTSCREWG11-08-20U (4)

RCP-2 (BRN-2)BUFFET TABLE

110V CONNECTIONSSCREWG39-06-24U (4)CLAMP10495-01-000 (2)SCREWG67-10-12U (2)

14W DINETTE

21R DINING/BUFFET/POWERED TV

RCP-2 (BRN-2)TV

THROW-IN WIRE #6

RCP-B (BRN-2)UNDER BUFFET

DB

SP-06

SP-06

RCP-2 (BRN-2)BDRM FRT

RCP-2 (BRN-2)BDRM RR

078

ALL WEATHER UPGRADE PACKAGE

THROW-IN WIRE #8

078

RCP-B (GRN)BATHWALL-3

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000127426 / 32474701000 2 OF 612-Jan-2018

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

2651B1

7.

1B1 CODES/STANDARDS USA

265 CODES/STANDARDS-CSA/CMVSS

1D5 ENTERTAINMENT CENTR/EXT W/CD

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

NOTES:

WIRE ROUTED IN SIDEWALL.

2

1

SEE ENTERTAINMENT CENTER COMPL FOR ADDITIONAL INFORMATION.3

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.4

WIRES ROUTED THROUGH FLOOR IN THIS AREA.5

6

ROUTE GROUND WIRE (8 GA GRN) FROM LOAD CENTERTHROUGH FLOOR TO GROUND BOLT ON CHASSIS FRAME RAIL.

LOAD CENTER GROUND WIRES MUST BE ATTACHED DIRECTLYTO CHASSIS GROUND.

4

RCP-EXT ENTCTR (BLU)

2

RCP-2 (BRN)SDWL,RH,FRONT

1D5

5

SP-06

RCP-3 (YEL)REFRIGERATOR

1

6

3

MODULE-POWERSHARE

DETAIL CA

4X4 BOXDETAIL CA

4 12D

BOX8289-01-000SCREWG11-08-12U (2)COVER8294-01-000WIRE ASM-GROUND133678-01-000CONNECTOR8313-01-000 (3)

CONNECTOR8356-01-000

CONNECTOR8356-02-000

TO 4X4 BOXUNDER DINETTEPART OF WIREASM-CHASSIS

FROM RELAY-EMS

110V CONNECTIONSSCREWG39-06-24U (4)CLAMP10495-01-000 (2)SCREWG67-10-12U (2)

THROW-IN WIRE #1

DA

RCP-B (BRN-2)WARDROBE 1

RCP-2 (BRN-2)BDRM DVD

RCP-1 (BRN-2)BDRM TV SP-06 1

RCP-3 (BLU)SOFA AIR BED

12D

078 FROM LOAD CENTER

078

ELECTRICAL SYSTEM 30 AMP12D

ALL WEATHER UPGRADE PACKAGE078

PANEL-RECEPTACLE188004-02-CHTSCREWG39-10-12U (2)

RCP-1 (YEL)CONVERTER

RCP-B (BLU)UNDER REFRIG

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000127426 / 32474701000 3 OF 6

RCP-B (BRN)RH,FRONT

CB

VIEW CA

432

305

RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BLU) (REFRIG CABT)

1B1

265

LOAD CENTER/ATS ASM000131184 / 325658-01-000

GROMMET108505-01-000

12-Jan-2018

NOTES:

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

1B1

2651B1

CODES/STANDARDS USA

265 CODES/STANDARDS-CSA/CMVSS

THROW-IN WIRE #5

CLAMP10495-01-000 (4)SCREWG67-10-12U (4)

FROM WIRE ASM-CHASSIS (BLU)

THROW-IN WIRE #2

FROM WIRE ASM-CHASSIS (BRN-2)

VIEW DA

BRACKET-110V CONNECTOR155223-05-CHTSCREWG39-08-12U (2)

LOAD CENTER(REF)

ALS(REF)

4X4 BOX(REF)

GFI-REFRIGCABT (REF)

RCP-BLANK(BLU) (REF)

CONNECTOR-WIRE,NM, CLEAR144283-02-000SCREWG39-06-24U (4)

DETAIL DB

CLAMP10495-01-000 (5)SCREWG67-10-12U (5)

591

THRU RCP-2 BDRM,REARTO RCP-2 BDRM,FRONT

SLIDEOUT WIRE #1(BRN)

CLAMP10497-03-000 (2)SCREWG39-06-12U (2)

SCREWG39-06-24U (4)

WIRE MUST BE ROUTED THROUGH CLAMPS AS SHOWN.1

RUN 12V WIRE ALONG WITH SLIDEOUT WIRE #2.2

WIRE ROUTED IN SIDEWALL.3

1 2

3

180

115

078

12D

CONVERTER(REF)

LOAD CENTER(REF)

4

PANEL-RECEPTACLERCP-1 YEL(REF)

4 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

12D ELECTRICAL SYSTEM 30 AMP

078 ALL WEATHER UPGRADE PACKAGE

12D

078

078

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000127426 / 32474701000 4 OF 612-Jan-2018

NOTES:

ALL OUTLETS DOWN STREAM AND INCLUDING THISOUTLET ARE GROUND FAULT INTERRUPT PROTECTED.

WIRE IN ROOF.

WIRE IN SIDEWALL.

30 15 15 20 15 20

CONTROL CENTER

CHASSISGROUND

8 GRN

ROOFAIR

CONDITIONER

RCP-BLANK,BATHWALL 1

12-2 12-214-2

14-2

RCP-GFIREFRIG

CABT 12-2

RCP-EXTENT

CENTER

NEUTRAL

EMSRELAY

NEUTRAL

NEUTRAL

SECONDARYPRIMARYLINE

WATERHEATER

4X4 BOX(LOCATED UNDER

REFER CABT)

RCP-BATH

RCP-EXT COMPT

RCP-MICROWAVE

4X4 BOX(BEHIND RANGE)

RCP-REFRIGERATOR

1

2

3

4

1

5

1D5

4

2

4

3

SEE MANUFACTURER'S DIAGRAM FOR ADDITIONAL INFORMATION.

WIRE IS PART OF WIRE ASM-CHASSIS.

5

RCP-BLANKUNDER LAV

12-2(BLK)

RCP-SOFA

2

110V CONNECTION(UNDER REFRIG)

RCP-BLANKREFRIGERATOR

RCP-GALLEY

RCP-BDRM DVD

3

4

RCP-SDWL,RH,FRONT

RCP-OVHD A/V CABT

RCP-TV POWER

CONTROLLER

110V CONNECTION(UNDER REFRIG)

110V CONNECTION(UNDER DINETTE)

2

RCP-BLANKBATHWALL 2

14W RCP-DINETTE

4

21R RCP-BUFFET

RCP-GALLEY

COUNTERTOP

4

110V CONNECTION(BEHIND SOFA)

RCP-TV

RCP-BLANKDINETTE110V CONNECTION

(RGT RR COMPT)110V CONNECTION(RGT RR COMPT)

TRANSFERSWITCH

401

RCP-SAT PREP

RCP-BDRM TV

68R

RCP-BLANKWARDROBE 1(UNDER WARDROBE)

RCP-BDRM FRT

RCP-BDRM RR

110V CONNECTION(UNDER BED)

110V CONNECTION(UNDER BED)

4

THROW INWIRE #1

THROW INWIRE #5

WHT

FLEX CORD

SLIDEOUTWIRE #1

THROW INWIRE #7

THROW INWIRE #2

THROW IN WIRE #6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

ENTERTAINMENT CENTR/EXT W/CD

DINING/BUFFET/POWERED TV

DINETTE

INVERTER-DC/AC, 1000 WATT

2651B1

1B1

265

1D5

21R

14W

401

40A INVERTER-DC/AC WITHOUT4

CONNECTTOGETHERWITH 40A

CONNECTOR144283-02-000

AUTOMATICTRANSFER

SWITCH 5

10-2

GENERATOR

THROW IN WIRE #8

POWERCORD

10-2

5

14-2

12D ELECTRICAL SYSTEM 30 AMP

12D

10-2

TV - FRONT68R

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000127426 / 32474701000 5 OF 6

RCP-BLANKRH FRONT

5

12-Jan-2018

NOTES:

ALL OUTLETS DOWN STREAM AND INCLUDING THISOUTLET ARE GROUND FAULT INTERRUPT PROTECTED.

WIRE IN ROOF.

WIRE IN SIDEWALL.

1

2

3

4

WIRE IS PART OF WIRE ASM-CHASSIS.

110V CONNECTION(UNDER REFRIG)

110V CONNECTION(BEHIND SOFA)

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

ENTERTAINMENT CENTR/EXT W/CD

DINING/BUFFET/POWERED TV

DINETTE

INVERTER-DC/AC, 1000 WATT

2651B1

1B1

265

1D5

21R

14W

401

40A INVERTER-DC/AC WITHOUT

078 ALL WEATHER UPGRADE PACKAGE

078

8 GA

GENERATOR

RECP-BLANK,BATHWALL-1

FRONTROOF AIR

CONDITIONER

RCP-REFRIGERATOR

L2

1520

12-2

50 50

12-2

12-2

WATER HEATER(LOCATEDBENEATH

GALLEY CABT)

3

POWERCORD

8 GRN

6-3

L1

15

12-2

CHASSISGROUND

GROUND

14-2

N

14-2

WHT

20

8 GRN

WIRE SUPPLIEDWITH GENERATOR

LOAD CENTER

20

14-2

12-2

EMS

YEL 2

1515

12-2

R2

R1

4X4 BOX(LOCATED UNDER

REFER CABT)

4X4 BOX(BEHIND RANGE)

2

12-2(BLK)

FLEX CORD

RCP-MICROWAVE

4

110V CONNECTION(RGT RR COMPT)

110V CONNECTION(RGT RR COMPT)

4

RCP-SDWL,RH,FRONT

40A

TRANSFERSWITCH

401

CONNECTTOGETHERWITH

RCP-OVHD A/V

CABTRCP-

SAT PREP

RCP-BLANKWARDROBE 1(UNDER WARDROBE)

RCP-BLANKBATHWALL 2

3

110V CONNECTION(UNDER DINETTE)

14W RCP-DINETTE

4

CONNECTOR144283-02-000

2

110V CONNECTION(UNDER REFRIG)

THROW INWIRE #2

RCP-BDRM DVD

21R

RCP-BUFFET

RCP-BLANKDINETTE

THROW IN WIRE #6RCP-

BDRM TV

RCP-TV

THROW IN WIRE #8

RCP-BDRM FRT

RCP-BDRM RR

THROW INWIRE #7

110V CONNECTION(UNDER BED)

110V CONNECTION(UNDER BED)

4

SLIDEOUTWIRE #1 4

RCP-BLANKREFRIGERATOR

RCP-GFIREFRIG

CABT

RCP-EXTENT

CENTER

RCP-EXT COMPT

1

1D5

RCP-SOFA

2

WHT

THROW INWIRE #1THROW IN

WIRE #5

RCP-BATH

4

RCP-BLANKUNDER LAV

RCP-GALLEY

RCP-GALLEY

COUNTERTOP

4

BLK

BLK/YEL

GROUND

WHT

RED

8 GRN

REARROOFAIR

CONDITIONER12-2

3

RCP-BLANK,BATHWALL 3

12-2

14-2

WHT

BLK

AUTOMATICTRANSFER

SWITCH

BLKRED

6-3

14-2

TV - FRONT68R

RCP-TV POWER

CONTROLLER

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000127426 / 32474701000 6 OF 6

RCP-BLANKRH FRONT

68R

15

14-2

RCP-CONVERTER

5

SEE MANUFACTURER'S DIAGRAM FOR ADDITIONAL INFORMATION.5

12-Jan-2018


Recommended