FINAL ASSEMBLY
8910/207818E010
PLATE,I-COMM1 65000550 7804M205
1 17200012 CONTACT, N.O.
2 17200013 CONTACT, N.C.
1 LABEL, PORTUGUESE, ELECTRICAL SET, 89007818M33053850511
3 2 51000001 FUSE,.5AMP,600V,TIME DELAY +
4 1 51000002 FUSE,1AMP,250V,TIME DELAY
5 1 51000003 FUSE HOLDER,2POLE,600V,30A +
6 2 51000004 FUSE HOLDER,1POLE,300V,12A +
7 1 51000005 FUSE,2AMP,250V,TIME DELAY
9
12
13
14
15 1 73100019 TERMINAL,END BAR,FUSE HOLDER
16 2 73100024 TERMINAL,END STOP,SCREWLESS
17 30 73250004 TIE,CABLE,NYLON,4",18#
18 1 73550029 XFMR,100VA,208/230/460V:24/115
19 4 74100004 WSHR,LOCK,INT/EXT,#10,ZNC
20 2 73100087 TERMINAL,WA,CAGE,20A,3HOLE,GND
21 1 73100086 TERMINAL,WA,CAGE,20A,3HOLE,BAR
22 1 73100082 TERMINAL,WA,CAGE,20A,JUMP,3P
23 11 73100085 TERMINAL,WA,CAGE,20A,3HOLE
24 1 65100022 9999E050 CONTROLLER, I-COMM
25 1 65700006 POWER SUPPLY,DIN,24VDC,18W
26 4 71300005 STANDOFF,NYLON,PCB,3/16X1
27 1 51950067 9999M028 DISPLAY,LCD,2-LINE,W/ CONN
28 1 38120006 DIN RAIL,LOW-PROFILE,6-1/2"
29 2 71300009 STANDOFF,NYLON,PCB,0.1"X7/16
30 1 52000031 HARN,WIRE KIT,CBOX,89001
31
32
1 12200068 7804M204 BACKPANEL,PNCH,14X16,W/FLNG
1 53850492 9999M027 LABEL, I-COMM TERMINALS
OR 2 51000023 FUSE,1AMP,600V,CC,TIME DELAY
400-575V
200-240V
8 67850015 SCR,PHLP,DR/TP,#8X1/2
10 2 67850065 SCR,FHWH,#8X9/16BLK K-LATH
11
� �
SOCKET, RELAY, 1-POLE, 250VAC, 10AMP
*DIN RAIL,LOW-PROFILE,3-1/2" (ALSO FOR WIRELESS OPTION)
ALARM, AUDIBLE, 24AC/DC , 22.5MM (NOT SHOWN)
LABEL, AREA DETECTOR, ALARM (NOT SHOWN)
HARN, KIT, I-ZONE (NOT SHOWN)
HARN,WIRE KIT,WARN DVC RLY,ICM
� �
WARNING DEVICE RELAY
I-ZONE OPTIONAL
OPTIONAL RADIO CONTROL
OPTIONAL LOOP CONTROLLER
56
AND
54
AND
52
AND
53
55
51
1
1
1
1
1
1
1 17500010
52000035
11050007
53850402
70350002
66450014
38120029
520000361
59
58
60
2"
2"
1" 74000014
74000019
74000020
RLY,SPDT,24VDC,10AMP
CTRLR,IND LOOP,DUAL,12/24V
9999M011
VELCRO, PSA, LOOP,BLACK, 1"
VELCRO, PSA, LOOP, BLACK, 2"
VELCRO, PSA, HOOK, BLACK, 2"
81
81 1
*TERMINAL,END STOP,SCREWLESS (ALSO FOR WIRELESS OPTION)AND 2 73100024
DWG. NO.
1 1 17000015 CONTACTOR, REVERSING 9-AMP W/ INTERLOCK
2 1 16660017 RELAY, OVERLOAD 1.8-2.6A
OR 1 16660016 RELAY, OVERLOAD 2.6-3.7A
OR 1 16660019 RELAY, OVERLOAD 3.8-5.5A
OR 1 16660018 RELAY, OVERLOAD 1.2-1.8A
CONTACTOR, REVERSING 12-AMP W/ INTERLOCKOR 1 17000016
OR 1 16660020 RELAY, OVERLOAD 5.5-8.0A
LABEL, ENGLISH, ELECTRICAL SET, 89007818M32953850502
LABEL, SPANISH, ELECTRICAL SET, 89001 53850507 7818M331
81 1
1 38120027 DIN RAIL,LOW-PROFILE,5.25"LONG
OR 1 73550030 XFMR,100VA,380/415/575V:24/115
208-240, 460-480V
400, 415 & 575V
33
34
35
36
37
SWITCH, E-STOP
SWITCH, PB, FLUSH, BLACK
SWITCH, PB, FLUSH, GREEN1
1
1
72700085
72700006
72700104
LABEL, NAMEPLATE1 53850430 8804M598
ENCLOSURE, MACHINED 16x14x8, WITH WINDOW1 43750129 7818M325
82
82
82 53850508 7818M328 LABEL, CBOX, 8900, ENCLOSURE1
53850500 7818M326 LABEL, CBOX, 8900, ENCLOSURE1
53850510 7818M327 LABEL, PORTUGUESE, CBOX, 8900, ENCLOSURE1
38 CONNECTOR, CONDUIT, 1", LIQUID TIGHT1 16960001
7818-E-021 REV. GPRIOR
PART #
MODEL NUMBER
REVSHEETDWG NO
DATE ISSUED
R
C
BY APPROVEDDATEECNDESCRIPTION
REVISION HISTORY
REV
1
A
C
B
D
A
B
C
D
2345678
8 7 6 5 4 3 1
REVDWG NO
TITLE
SIZE
DSHEETSCALE
DO NOT SCALE DRAWING
DATE
DATE
DATE
CHECKED BY
APPROVED BY
DRAWN BY
REF
INITIAL ECN
OVER
0
INCH TOLERANCES
UP TO
0.125
5
1.25
40
80
15
0.25
1.25
15
40
5
FINISH
+/- 1 DEG
80
ANGLES
0.125 0.25 0.010
0.040
0.060
0.100
0.125
0.020
0.030
+ / -
0.005MM-DD-YY
NEXT ASSEMBLY
PARTS LIST / MATERIAL
ITEM PART NO.QTY DESCRIPTION
RITE-HITE DOORS INC.
7818E032
7818E032
1"=1"
H
H
TRAKLINE - ROLL & FOLD
CONTROL BOX LAYOUT
UNIVERSAL CONTROLLER
8910/8920/8920PL
1740
RPB 12/27/2005
4994
2/20/20062005
G ADD ACTIVATION OPTIONS 6825 1/22/2014 TAH
H BEA RADIO CONTROLS 6893 7/15/2014 TAH
F MULTIPLE BUTTON TRANSMITTERS 6520 6/14/2012 TAH
RCVR,BEA,433,12-24V,1FN
TRANS,BEA,433,3BTN
OR A/R 73750079
A/R 73750078
OR
57
A/R
1
73750080
66250020
TRANS,BEA,433,2BTN
TRANS,BEA,433,1BTN
HARN,DUAL LOOP CTRLR,UNIVAND 1 52000067 9999M042
WIRELESS ACTIVATION OPTION
CTRLR,WIRELESS ACT,BTR,12-24V
AND
61 1 17500025
*SEE INDUCTION LOOP OPTION BELOW
OR 1 65700007 POWER SUPPLY,DIN,24VDC,30W,CGDC POWER CONSUMPTION > 22W
DC POWER CONSUMPTION <= 22W
AND 1 52000068 HARN,WIRELESS HOST,ICOMMII9999M043
39 SCR,GROUND,#10-32X3/81 67850177
40 LABEL,GROUND1 53850048
TORQUE INSTRUCTIONS:
1. TIGHTEN TO RECOMMENDED MIN TORQUE SETTING.
2. PULL TEST ALL WIRES.3. IF WIRE PULLS OUT, TORQUE AGAIN TO MINIMUM VALUE, GENTLY HAND TIGHTEN UNTIL
WIRE CANNOT BE PULLED LOOSE.
SCREW TERMINAL MIN TORQUE SETTING
INSTALLED OPTIONAL COMPONENTS
� WIRELESS ACTIVATION HOST
� INDUCTION LOOP CONTROLLER
� INTERLOCK WIRING
� RADIO CONTROL
� ANNOUNCE OPTION (K8)
� I-Zone
RHC# _______________
SERIAL# _______________
NOTE: OPTIONAL DEVICES WILL ONLY
BE CHECKED ON THE WIRING DIAGRAM
INCLUDED WITH THE CONTROL BOX.
NOTE: ALL D.C. CONTROL (24 VOLTS) WIRES
ARE BLUE. ALL A.C. (24 VAC) CONTROL
WIRES ARE RED. ALL CONTROL CIRCUITS
ARE GROUND REFERENCED.
ALL WIRE IS 18 AWG UNLESS NOTED.
WIRE HARNESS SHOULD MEET THE FOLLOWING
SPECIFICATIONS:
UL R/C (AVLV2) / CSA CERT.
AWM/MTW, 18 GAGE MIN. UNLESS NOTED.
80°C MIN. 600V
ABOVE FOR PROPER TAPS.SEE TRANSFORMER SETTINGS
102.372.10380-415(1 HP)
8920(1 HP OR
1.5 HP)
(2 HP)
8920PL
575
440-480
380-415
230-240
2.45
3.17
6.33
3.64
2.62
3.40
3.90
6.77
15
15
15
15
> 144 SQ. FT.
575
208
440-480
230-240
380-415
1.83
1.50
6.33
2.10
3.65
=< 144 SQ. FT.208 SIZE
208 SIZE
575
440-480
3.65
4.20
1.83
1.50
2.05
1.68
6.81
4.09
2.37
10
10
15
10
10
4.13
4.68
2.05
1.68
10
10
10
10
BACKPANEL P/N: 1226.XXXX
CONTROL BOX P/N: 1731.XXXX (OPTIONAL)
F4
CB1
8910
(1 HP)
8920
8910
MODEL
MODEL
1.5 HP)
(1 HP OR
(2 HP)
8920PL
USE ONLY RECOMMENDED SETTING
TORQUE
COIL OHMS
COIL VOLTAGE
6.9 AMPS208
SUPPLIED BY THE END USER AND COMPLY
BE BASED ON INTERMITTENT DUTY.
CODES. SIZING FOR PROTECTIVE DEVICES MAY
WITH ALL NATIONAL AND LOCAL ELECTRICAL
NOTE: BRANCH CIRCUIT PROTECTION MUST BE
VOLTAGE
208
230-240
3.65
3.65
F.L.A.MOTOR SERVICE
AMPS
4.13
4.09
F.L.A.TOTAL
10
10
6.3 AMPS
3.6 AMPS
2.5 AMPS
3.2 AMPS
10 Nm
BRANCH CIRCUIT PROTECTION
BRAKE RATINGS
328 OHMS
7.5 FT LB
105 VDC
575
440-480
230-240
380-415
FROM END USER
SUPPLIED DISCONNECT(SEE TABLE)
USE COPPER CONDUCTORS RATED AT 60°C OR HIGHER
INCOMING POWER
3Ø
L2
L1
L3
PE PE
L3BK
BK
BK
L1
L2
#14 AWG
2.1 AMPS380-415
1.8 AMPS
1.5 AMPS
3.8 AMPS
3.7 AMPS
2.1 AMPS
1.5 AMPS
1.8 AMPS
4.2 AMPS> 144 SQ. FT.
575
440-480
230-240
380-415
=< 144 SQ. FT.208 SIZE
208 SIZE
575
440-480
SETTING
3.8 AMPS
3.7 AMPS
OVERLOAD RELAY SETTING
208
230-240
VOLTAGE
380-415
208-240
380-575
1 AMP
.5 AMP CC
1 AMP CC
BU
34
OPEN/RESET P.B. (X12)
MC1 = COMPONENT NAME9695MC2
VERIFY THAT THIS DRAWING HAS NOT BEEN SUPERCEDED BY NEWER REVISION. ABOVE APPLIES ONLY WHEN DRAWING IS CURRENT.
7818-E-010 REV. K
THIS DRAWING COVERS DOORS CONFIGURED AFTER 2-20-006
#14 AWG#14 AWG
BK
BK
GN/YE
BKV
MOTOR GND
MOTOR Ø1U
X1
T1
MOTOR Ø3
MOTOR Ø2W
T2
T3
14
PRIOR
SCOPE
OVERLOAD RELAY13O/L 1
T1 L1
T3
T2
L3
L2
= ASSIGNED TERMINATION NUMBER
= LOCAL TERMINATION NUMBER
= OPPOSITE END OF WIRE
= BOLD LINE = A.C. COMMON
= DASHED LINE = OPTIONAL EQUIPMENT
ALL BLACK WIRES ARE AT POTENTIALLYCAUTION:
T2T3 T1
L3 L1L2
T3
L3
LETHAL VOLTAGES.
T1T2
L1L2
5
35
35
A1
#14 AWG
GN/YEF4
0.1 KVA
TRANSFORMER
MC1
WH
BRAKE
BRAKEB1
B2
COMMON (OPT.)N
NX1
BK
B1
14
BK
BK
F3H4
T1 H3
H2
X2
X3
13
F1
A2
MC1A2
OPEN
CLOSE
MC2
FUSED 24VAC
FUSED 120VAC
H1
F1
F2
BK
N
RD
X1 WH
BK
RD
BK
BK
ELECTRICAL KEY:
= TERMINAL JUMPER
= TERMINAL BLOCK
MC1 MC2
5
A1
208
380
415
575
F1
F2
F3
USE ONLY RECOMMENDED VALUES
DEVICE
LINE VOLTAGE
220-240
440-480
LINE VOLTAGE
STANDARD TRANSFORMER SETTINGS
OPTIONAL TRANSFORMER SETTINGS
CURRENT RATING
380-575
208-240
-
.5 AMP CC
1 AMP CC
2 AMP
FOR REPLACEMENT
CONTROL BOX FUSING
VOLTAGE
- 1 AMP
H1-H2
H1-H3
H1-H4
TAPS
H1-H2
H1-H4
H1-H3
TAPS
CONTACTORDISCONNECT
INTERLOCKINVERTEROVERLOADTRANSFORMER
TERMINALSRELAYS
PLC (RH/AB)
COMPONENT
6
66666
55
4/2
20
2020202020
1212
10/5
(IN-LBS)
TORQUE SETTING
DRIVER
BU J3-3 J3-4
I-ZONE ALARM
(OPTIONAL)
La N J3-2 BU
POWER SUPPLY
PS1 +24V
0V
L
N
PE
IS2 2 1
RD
JOG P.B.
E-STOP
RD
96 1 AC2
RD
X0-
OP
EN
L/S
X1-
CLO
SE
L/S
X2-
AC
TIV
AT
ION
X3-
AC
TIV
AT
ION
X4-
NO
T U
SE
D
X5-
TO
GG
LE IN
PU
T
X6-
AC
TIV
AT
ION
X7-
AC
TIV
AT
ION
X8-
I-Z
ON
E 1
X9-
I-Z
ON
E 2
X10
-PH
OT
OE
YE
1
X11
-PH
OT
OE
YE
2
DC
-24V
DC
OV
-0V
DC
LP2-LOOP WIRE
LP1-LOOP WIRE
YDC3-DC OUTPUT
YDC2-DC OUTPUT
YDC1-DC OUTPUT
YDC0-DC OUTPUT
IR-INTERRUPT
AC-24V AC
N-NEUTRAL
N-NEUTRAL
AC-24V AC
AC-24V AC
K3N-K3 COMMON
IS1-FAULT/JOG SRC
IS2-FAULT/JOG RTN
K2-RELAY K2 OUT
K2N-K2 COMMON
K3-RELAY K3 OUT
J4-3
J4-2
J4-4
J4-5
J4-6
J4-7
J4-8
PART #
MODEL NUMBER
REVSHEETDWG NO
DATE ISSUED
R
C
BY APPROVEDDATEECNDESCRIPTION
REVISION HISTORY
REV
1
A
C
B
D
A
B
C
D
2345678
8 7 6 5 4 3 1
REVDWG NO
TITLE
SIZE
DSHEETSCALE
DO NOT SCALE DRAWING
DATE
DATE
DATE
CHECKED BY
APPROVED BY
DRAWN BY
REF
INITIAL ECN
OVER
0
INCH TOLERANCES
UP TO
0.125
5
1.25
40
80
15
0.25
1.25
15
40
5
FINISH
+/- 1 DEG
80
ANGLES
0.125 0.25 0.010
0.040
0.060
0.100
0.125
0.020
0.030
+ / -
0.005MM-DD-YY
NEXT ASSEMBLY
PARTS LIST / MATERIAL
ITEM PART NO.QTY DESCRIPTION
RITE-HITE DOORS INC.
7818E030
7818E030
1 of 1
1 of 1
9"=1'
C
C
TRAKLINE - ROLL & FOLD
WIRING DIAGRAM
i-COMM
8910/8920/8920PL
SEE ABOVE
RPB 10/13/2005
4994
2/20/20062005
A CORRECT J3 ER. DEPICTION 5065 7/21/2006 NCN
B switch push button 3, 4 6166 9/8/2010 MDB
C ADD ACTIVATION OPTIONS 6825 1/22/2014 TAH
JP1-JUMPER 1-2 & 3-4
USE SHUNTS PROVIDED
CONNECTOR TABLE
THIS TABLE SHOWS THE FUNCTION OF EACH OF
THE CONNECTORS ON THE UNIVERSAL CONTROLLER. THE VOLTAGES LISTED FOR EACH PIN ASSUME THAT EITHER THE INPUT OR OUTPUT
IS ACTIVATED.
CONN. PIN # FUNCTION VOLTAGE
J3
1 UNUSED OUTPUT 0 VDC
2 I-ZONE ALARM OUT 0 VDC
3 DC POWER OUT 24 VDC
4 RESET INPUT (X12) 24 VDC
J4
1 UNUSED
2 DC COMMON INPUT 0 VDC
3 DC POWER INPUT 24 VDC
4 24V AC INPUT 24 VAC
5 24V AC COMMON (N) 24 VAC
6 OPEN/CLOSE COMMON N
7 CLOSE OUTPUT (K1) 24 VAC
8 OPEN OUTPUT (K0) 24 VAC
J5
1 LOOP INPUT 2
2 LOOP INPUT 1
3 DC POWER OUT 24 VDC
4 DC COMMON OUT 24 VDC
5 DC POWER OUT 24 VDC
6 LOOP INPUT (X13) 24 VDC
K65 1
ANNOUNCE
(DC RLY.) OPTIONAL
GN/YE
ANNOUNCE STROBE (OPT.)
STB120VAC (OPT.)
4 3
K6
COMMON (OPT.)
5 TWISTS/FT. MIN
IND
UC
TION
LOO
PC
ON
TR
OLLE
R1
32
54
76
108
9
GN/YE 11
INDUCTION
LOOP A
INDUCTIONLOOP B
LPA
LPB
J5-3
J5-4
24VDC IN
0VDC IN
RELAY 1 (DC)
RELAY 1 (X13)
J5-5
J5-6
RD
BK
VT
GN
OPTIONAL WIRELESS ACTIVATION
0V
DC
X6
6
24
V
70V
8
CL
SG
9RE
10
BK
WY
OP
EN
2
CL
S
3
ST
OP
4
O/C
5
CO
M
AC
TIV
ATO
R
PO
WE
RS
AFE
TY
RF Com
Fault
Rem
otePairing
WIR
ELE
SS
HO
ST
SEE 7818E035 FOR PAIRING INSTRUCTIONS
12
34
5
67
89
10
WH
GN
BK
=< 144 SQ. FT.
> 144 SQ. FT.
440-480
8920PL
(2 HP)440-480
380-415
575
230-240
208
575
1.5 HP)
(1 HP OR8920
380-415
230-240
208 SIZE
208 SIZE
575
1.83
3.17
3.64
2.45
1.50
6.33
6.33
4.20
2.10
3.65
1.50
3.65
NOTE: BRANCH CIRCUIT PROTECTION
MUST BE SUPPLIED BY THE END USER
BRANCH CIRCUIT PROTECTION
LOCAL ELECTRICAL CODES. SIZING FOR
PROTECTIVE DEVICES MAY BE BASED
AND COMPLY WITH ALL NATIONAL AND
ON INTERMITTENT DUTY.
(1 HP)
8910
MODEL
230-240
380-415
440-480
VOLTAGE
208
MOTOR
3.65
2.10
1.83
3.65
F.L.A.
GNYE
BLK #3
BLK #1
BLK #2
BRAKE
OPEN LIMIT
BLK #4
BLK #5
UPPER REVERSING
OPTIONAL - THRU-BEAM
STANDARD - RETROREFECTIVE
OPTIONAL - THRU-BEAM
STANDARD - RETROREFECTIVE
ARE SET TO "LIGHT OPERATE".NOTE: ALL REVERSING PHOTOEYES
PHOTO-EYE
LOWER REVERSING
BK
CLOSE LIMIT
BU 1BU 1 BU
OG
BR
PHOTO-EYE
OG 4
3
2
BR
BK
4 WH
2
3 BR
OG
3BR
2
1BU
BK
4OG
BR3
2
1 BU
BK
4 WH
GN11 GN
3ø INCOMING POWER FROM END
USER SUPPLIED DISCONNECT.
USE COPPER CONDUCTORS RATED
AT 60°C OR HIGHER
NOTE:
USE ONLY FACTORY SUPPLIED CABLE
FOR MOTOR, PHOTOEYES, & LIMIT
SWITCHES. CLIP
4
3
1
2
4
3
1
2
GNYE
BLK #3
BLK #2
BLK #1
16 GA. / 7 CONDUCTOR SHIELDED CABLE
1
2
1
2
BLK #4
BLK #5
GNYE
BLK #3
BLK #4
BLK #2
BLK #1
BLK #6
BLK #5
L1
B2 ** NOTE: THE RD & BK
WIRES IN TERMINALS W & V
MAY BE REVERSED TO
CHANGE MOTOR ROTATION.
N EUROPEAN ONLY
L2
L3
PE
V
U
**W
B1
(LESS THAN 30 VOLTS)
LOW VOLTAGE TERMINALS
HIGH VOLTAGE TERMINALS
(GREATER THAN 100 VOLTS)
18 GA. / 2 CONDUCTOR CABLE
BU
BR
22 GA. / 5 CONDUCTOR CABLE
18 GA. / 3 CONDUCTOR CABLE
3
2
3
2
WH
BK
WH
BK
BU
1
2
1
2
WH
BR
OG
BK
2
1
2
1
WH OR RD
BK
BU
BR
1
2
BK1
WH2
LOWER REVERSING PHOTO-EYE
THRU-BEAM EMITTER OPTIONAL
UPPER REVERSING PHOTO-EYE
THRU-BEAM EMITTER OPTIONAL
AC* 24 VAC
N* AC COMMON
X10* P.E. INPUT
X11* P.E. INPUT
N* AC COMMON
AC* 24 VAC
DC* DC POWER
DC* DC POWER
X0* OPEN L.S.
X1* CLOSE L.S.
* NOTE: TERMINALS MARKED
WITH AN (*) ARE LOACTED
ON THE i-COMM
CONTROLLER.
PART #
MODEL NUMBER
REVSHEETDWG NO
DATE ISSUED
R
C
BY APPROVEDDATEECNDESCRIPTION
REVISION HISTORY
REV
1
A
C
B
D
A
B
C
D
2345678
8 7 6 5 4 3 1
REVDWG NO
TITLE
SIZE
DSHEETSCALE
DO NOT SCALE DRAWING
DATE
DATE
DATE
CHECKED BY
APPROVED BY
DRAWN BY
REF
INITIAL ECN
OVER
0
INCH TOLERANCES
UP TO
0.125
5
1.25
40
80
15
0.25
1.25
15
40
5
FINISH
+/- 1 DEG
80
ANGLES
0.125 0.25 0.010
0.040
0.060
0.100
0.125
0.020
0.030
+ / -
0.005MM-DD-YY
NEXT ASSEMBLY
PARTS LIST / MATERIAL
ITEM PART NO.QTY DESCRIPTION
RITE-HITE DOORS INC.
7818E034
7818E034
9"=1'
B
B
TRAKLINE - ROLL & FOLD-ENCLOSURE
EXTERNAL FIELD WIRING DIAGRAM
i-COMM CONTROLS
8910/8920/8920PL
RPB 1/9/2006
4994
2/20/20062006
A ADDED SHIELDED MOTOR CABLE 6828 2/18/2014 JJS
B ADDED RING CONNECTOR 6887 6/27/2014 JJS
VERIFY THAT THIS DRAWING HAS NOT BEEN SUPERCEDED BY NEWER REVISION. ABOVE APPLIES
ONLY WHEN DRAWING IS CURRENT.
7818-E-009 REV. KPRIOR
THIS DRAWING COVERS DOORS CONFIGURED AFTER 2-20-2006
SCOPE
TRIM FOIL SHEATH
DRN/BRD DRN/BRD DRN/BRD TERMINATED
ON BACK PANEL
PART #
MODEL NUMBER
REVSHEETDWG NO
DATE ISSUED
R
C
R
BY APPROVEDDATEECNDESCRIPTION
REVISION HISTORY
REV
1
A
C
B
D
A
B
C
D
2345678
8 7 6 5 4 3 1
REVDWG NO
TITLE
SIZE
DSHEETSCALE
DO NOT SCALE DRAWING
DATE
DATE
DATE
CHECKED BY
APPROVED BY
DRAWN BY
REF
INITIAL ECN
OVER
0
INCH TOLERANCES
UP TO
0.125
5
1.25
40
80
15
0.25
1.25
15
40
5
FINISH
+/- 1 DEG
80
ANGLES
0.125 0.25 0.010
0.040
0.060
0.100
0.125
0.020
0.030
+ / -
0.005MM-DD-YY
NEXT ASSEMBLY
PARTS LIST / MATERIAL
ITEM PART NO.QTY DESCRIPTION
RITE-HITE DOORS INC.
7818E035
7818E035
RITE-HITEDOORS INC.
9"=1'
A
A
TRAKLINE SERIES
ACTIVATION WIRING
8900
TAH 1/22/2014
6825
1/22/20142014
A BEA RADIO CONTROLS 6893 7/15/2014 TAH
FINAL ASSEMBLY
NOTES
This drawing assumes input functions are set to factory defaults. Consult i-Comm manual for details. WARNING - never connect motion sensors to a toggle input.
Terminals "X6", "X7" are automatic reclose.
Terminal X7 on the motor terminal strip can be used for activation devices such as motion sensors and pull cords.
Terminals "DC" are DC common for inputs.
**For true toggle operation use terminal "X5".
(Pull cords, push button or radio controls only.)
***For Reverse hold open connect sensors to UNUSED input.
(i.e. X3, X6, or X7 and assign that input a function of "6" in the i-COMM menu. Multiple sensors can be connected in parallel.
Consult i-COMM manual and/or Door manual for additional instructions.
Control Box
Warning Device Strobe
120VAC U.L. Listed .30 Amp Max
Additonal Relay Required
N
STB
Wire
Beacon/Strobe
Wire
BEA Motion Sensors
Presence Sensor
X6***
DC
X3***
DC
Control Box
Control Box
Wire Each device as shown.
Control Box
WH
GN
X6**
DC
STB
Switch
SW
SW
N
DC
N
AC
Wire
Wire
Alarm
Photoeye
BK
BU
BN
BEA MATRIXINDUCTION LOOP
PHOTOEYESPUSHBUTTONS & PULL-CORDS
120V STROBE 120VAC ALARM
Warning Device Strobe
120VAC U.L. Listed .30 Amp Max
Additonal Relay Required
X6***
DC
BEA IS40 Motion/Presence Sensor
4-GN
3-WH
5-YE
X3***
DC
GRN/BLK
YE/BLK
Presence Sensor
DC
X3***
BN
BU GN
WH
YE
Set X3 to a value of 6-Reverse
IS-40 Hold OpenSet X3 to a value of (6-Reverse)
WH/BLK
not used
not usedSet X3 to a value of 6-Reverse
BN
BU
not used
not used
not used
CONTROL BOX WIRING
PREANNOUNCE RELAY
STB3
CR31
4
5DC YDC_
F1 or L
See X7 noteSee X7 note
See X7 note
See X7 note
Control Box Control Box
0V
DC
0V
DC
Sensor
BK
RD
BEA - Falcon, Eagle,
MS08 BEA - DK-12US Control Box
0V
DC
BEA - IS-40
2-BK
1-RD
Control Box
0V
DC
Sensor
BK
RD
BEA - IRIS
BK
RD
Retroreflective or Thru Beam Receiver
Control Box
Thru Beam Emitter
AC
N
X6*
Photoeye
BN
BU
OG
PHOTOEYES
Standard configuration is combined mode with DIP switches #1-9 in the OFF position and DIP switch #10 in the ON position. For independent mode and other DIP switch settings, consult the
BEA Matrix D12-24 User Manual.
X3
DC
LZR-i30 Presence Sensor
WH
ORG
BLK/WH
GRN/WH
GRN
not used
Control Box
0V
DC
BEA - LZR-i30
BK
RD
ORG/BLKnot used
BU
WH/BU
DC
0V
Sensor Sensor
WARNING DEVICE RELAY
BEA ACTIVATION
MISCELLANEOUS
ACTIVATION
PREANNOUNCE
DEVICES
Pairing:
WIRELESS
PUSHBUTTONS & PULL-CORDS
Control Box
X6**
DC
DC
0V
Host (Receiver)
6
4
5
7
To pair with a wireless device, first remove the plastic strip under the batteries in the remote unit to energize the device. On the Host (Receiver)
press "Remote Pairing". The "RF Com" LED will begin to flash. Next press the pair button on the remote unit. The units will then pair. Activate the door to test. Repeat procedure if necessary.
1 2 3 4 5
6 7 8 9 10
6
24V
7
0V
8
CLSG
9
RE
10
BKWY
1
OPEN
2
CLS
3
STOP
4
O/C
5
COM
ACTIVATOR
POWER SAFETY
RF Com
F aul t
RemotePairing
2.4GHz Wireless Activation
WIRELESS HOST
not used
not used
Set the input to 6 - Reverse N/C.
5 TWISTS/FT. MIN
IND
UC
TION
LOO
PC
ON
TR
OLLE
R
13
25
47
610
89
GN/YE 11
INDUCTIONLOOP A
INDUCTION
LOOP B
LPA
LPB
J5-3
J5-4
24VDC IN
0VDC IN
RELAY 1 (DC)
RELAY 1 (X13)
J5-5
J5-6
RD
BK
VT
GN
gray cable.
Sensor is connected by 4-conductor
X8
X9
DC
0V
GN
CLR
RD
BK
I-ZONEControl Box Sensor
I-ZONE 8900 w/
CONTROL BOX
gray cables. Green wire is not used.
Sensor is connected by 4-conductor
Sensor
SensorControl Box I-ZONE
Control Box
X9
0V
DC
0V
X8
DC
I-ZONE
CLR
BK
RD
BK
CLR
RD
I-ZONE 8900 w/ SIDEFRAME
CONTROLSINTERLOCKS
Relay Air Curtain
AIR CURTAIN INTERLOCK (120V)
11(4)
14(3)
Output Com
Ouput
A2(1)
A1(5)
i-COMM
YDC_
DC
Note: Consult i-COMM manual for
available output functions. Connect
relay contact to Air Curtain control.
Change YDC_ to 1 (on when door
not closed). Separate relay must be
used for isolation with 120VAC.
INSTALL SPDT RELAY IN CBOX
11(4)
DC COILA2(1)A1(5)
14(3)
Control Box Air Curtain
AIR CURTAIN INTERLOCK (24V)
YK3N
YK3
Output Com
Ouput
Note: Consult i-COMM manual for
available output functions. Connect
YK3 & YK3N to Air Curtain control.
Change YK3 to 1 (on when door not
closed).Note: Consult i-COMM manual to
see which inputs can be assigned
interlock in function. Connect YK3
to whichever input is selected to
become interlock in. No other devices should be connected to
this input. Terminal must be
assigned to Interlock through
i-COMM menu on both doors. (i.e.
If X3 is to be assigned a function of
Interlock Input, the menu ("Input
Func X3") should be set to a value
of "0")
Output YK3 (K3 relay) should
remain at the default setting of "0"
on both doors.
2 Door Non-Sequential Interlock
DC
YK3N
X?
YK3
Door1
YK3N
Door2
DC
X?
YK3
NON-SEQUENTIAL2 DOOR INTERLOCK
433MHz Radio Control
Control Box
X6**
DC
0V
DC
Receiver
BK
GN
RD
WH
RADIO CONTROL
1. SET DIP SWITCHES 1&2 TO OFF.2. PRESS LEARN W/NO DELAY.
3. PRESS TRANSMITTER BUTTON REPEATEDLY UNTIL BLUE LED ON RECEIVER ILLUMINATES.