GE Zoneline ® packaged terminal air conditioners 2007 contract sales architects and engineers data manual
Transcript

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 1/60

GE Zoneline®

packagedterminal air conditioners2007 contract sales architects and engineers data manual

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 2/60

Quick Reference

 

2800 Series Cooling with Electric Heat

2800 and 3800 SeriesControl Panel

5800 Series Control Panel

Full Specs on pages 54 and 55

ALL UNITS REQUIRE POWER CONNECTION KIT

Power Connection Kit determines resistance heat output7000 Btuh units do not activate 5 KW resistance heater

MODEL

NUMBER

COOLING

(Btuh)EER

AZ28E07DA* 7100/6900 12.7/12.7

AZ28E09DA* 9300/8900 12.0/12.0

AZ28E12DA* 11800/11500 11.5/11.5

AZ28E15DA* 14600/14300 10.2/10.2

AZ28E07EA* 7100 12.7

AZ28E09EA* 9000 12.0

AZ28E12EA* 11700 11.5

AZ28E15EA* 14600 10.2

Dr Air 25

2800 Series Cooling with Electric HeatMODEL

NUMBER

COOLING

(Btuh)EER

AZ28E07DAP 6800/6600 12.1/12.1

AZ28E09DAP 8600/8400 11.5/11.5

AZ28E12DAP 11200/11000 11.0/11.0

AZ28E07EAP 6800 12.1

AZ28E09EAP 8600 11.5

AZ28E12EAP 11200 11.0

3800 Series Heat Pump with Backup Electric Heat

MODEL

NUMBER

COOLING

(Btuh) EER

REvERSE CyCLE

BTUH COP

AZ38H07DA* 7100/6900 12.7/12.7 6400/6200 3.6/3.6

AZ38H09DA* 9000/8800 12.0/12.0 8400/8200 3.6/3.6

AZ38H12DA* 11700/11500 11.5/11.5 10900/10700 3.4/3.4

AZ38H15DA* 14600/14300 10.0/10.0 13400/13200 3.2/3.2

AZ38H07EA* 7100 12.7 6400 3.6

AZ38H09EA* 9000 12.0 8400 3.6

AZ38H12EA* 11700 11.5 10900 3.4

AZ38H15EA* 14600 10.0 13400 3.2

5800 Series Heat Pump with Backup Electric Heat

MODELNUMBER

COOLING(Btuh)

EERREvERSE CyCLE

BTUHCOP

AZ58H07DA* 7200/7000 13.0/13.0 6400/6200 3.7/3.7

AZ58H09DA* 9300/9050 12.0/12.0 8400/8200 3.6/3.8

AZ58H12DA* 11800/11600 11.7/11.7 10900/10700 3.4/3.4

AZ58H15DA* 14700/14400 10.3/10.3 13800/13800 3.2/3.2

AZ58H07EA* 7300 13.0 6400 3.7

AZ58H09EA* 9300 12.0 8400 3.6

AZ58H12EA* 11800 11.7 10900 3.4

AZ58H15EA* 14700 10.3 13800 3.2

*Dual rated 230/208-volt units are shown with ratings se parated b “/”.

Units with single rating are 265-volt units.

2

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 3/60

ge.com

Electric Heat Amps include electric heater and fan motor current draw.265-volt units are to be permanently connected in compliance with National Electrical Code and local codes and have a factory-installed junction box on the chassis.Each 265-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-bas e to chassis

and wiring to connect sub-base to building wiring.265-Volt Power Connection Kit must be ordered separately.

Power Connection Kits

Zoneline®

Chassis NomenclatureThe Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information andoptional features included on the unit. When specifying or ordering the Zoneline chassis, the use of this nomenclature willassure receiving the correct unit.

20/208-Volt Line Cord Connection Units

Line CordKit

ElectricHeatBTUH

ElectricHeaterWatts

ElectricHeatAmps

Min. CircuitProtection

(Amps)

RAK15 8600/7100 2550/2090 11.6/10.6 15

RAK20 11700/9600 450/2820 15.5/14.1 20

RAK0 170100/1900 5000/4090 22./20. 0

Electric Heat Amps include electric heater and fan motor current draw.Each Line Cord Kit has an integral Leakage Current Detection and Interruption (LCDI) or Arc Fault

Current Interrupter (AFCI) device as required by National Electrical Code (NEC) and UnderwritersLaboratories (UL) for units manufactured after August 1, 2004.

20/208-Volt Sub-Base and Direct Connected Units

Sub-BaseDirect

ConnectionKit

ElectricHeatBTUH

ElectricHeaterWatts

ElectricHeatAmps

Min. CircuProtection

(Amps)

RAK204D15P RAK4157 8600/7100 2550/2090 11.6/10.6 15

RAK204D20P RAK4207 11700/9600 450/2820 15.5/14.1 20

RAK204D0P RAK407 170100/1900 5000/4090 22./20. 0

Electric Heat Amps include electric heater and fan motor current draw.Units connected through sub-base do not require a LCDI or AFCI device since they are not

considered to be line-cord connected. Each 20/208-volt sub-base kit consists of sub-base withappropriate receptacle for minimum circuit amperage, chaseway to route power connector fromsub-base to chassis, wiring to connect sub- base to building wiring and a short line cord with 9-pconnector to connect to chassis and plug into receptacle in sub-bas e.Short sub-base line cord may not be used without sub-base.Junction box for 20/208-volt chassis must be purchased separately.RAK4002A for 2800 and 800 series units RAK4002B for 5800 series units.

265-Volt Sub-Base and Direct Connected Units

Sub-BasePower

Connection KitDirect

Connection KitElectric Heat

BTUHElectric Heater

WattsElectric Heat

AmpsMin. Circuit Protectio

(Amps)

RAK204E15 RAK5172 RAK5157 8600 2550 9.6 15

RAK204E20 RAK5202 RAK5207 11700 450 1.0 20

RAK204E0 RAK502 RAK507 17000 5000 18.9 0

Important

Essential Elements Ordering Overview

20/208-volt line cord connected units — order line cord kit

20/208-volt sub-base connected units — order sub-base and junction box

265-volt units — order sub-base and power connection kit

EXAMPLE

A Z 5 8 H 1 2 D A DChassis series28=deluxe line cool/

electric heat8=deluxe line heat pump58=premium line

heat pump

Unit typeE=cooling with electric

resistance heatH=heat pump with electric

resistance heat

Zonelinepackagedterminalchassis

Nominal cooling capacity07=7,000 BTUH cooling09=9,000 BTUH cooling12=12,000 BTUH cooling15=15,000 BTUH cooling

Special FeaturesB=base unitC=corrosion treated

D=internalcondensateremoval (ICR)system (heatpump modelsonly) (not forcoastal areas)

P=Dry Air 25 (2800Series only)

Voltage/Phase/FrequencyD=20/208-Volt,

single-phase, 60 HzE=265-Volt, single-phase,

60 Hz

Universalpower connection

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 4/604

The Zoneline® 2800, 800 and 5800 Series have incorporated changes suggested by customers, along withenhancements by GE’s Technology Team and changes necessary to meet new UL and NEC requirements.

“L” shaped condenser coil.

The “Partial Open Vent Air” feature was a specific request by a customer.

“Heat Sentinel” is an enhancement developed by GE’s Technology Team to help lodging professionals welcome their guestswith a moderate-temperature room and to help lower cooling costs.

Devices have been added on cord-connected units to protect against injury from unsafe power cords.

See the “Features and Benefits” section for in-depth explanation of these changes and the industry-leading features of GE Zoneline retained from the previous series.

The Deluxe 2800 Series Zoneline Models Includes The “Dry Air 25” Models

Which Remove 25% More Moisture Than Other Zoneline Models.

Deluxe Dry Air 25 ModelsCooling With Resistance Heat

• Remove 25% More Moisture than other Zoneline Models,up to 2.7 Additional Gallons Per Day

• Cool and Dry Air in Less Time than Standard Zoneline Models

• Heat Pipe is a Separate Sealed Refrigerant System

— No Mechanical Parts — No Special Maintenance Required

• Helps Maintain Lower Relative Humidity In Rooms

• Maintains Comfort at Slightly Higher Room Temperatures

— Reduces Operating Costs — Provides Comfort WithoutOvercooling

• Corrosion Treatment is Standard

• Excellent Choice for Humid Climates

• Available in 7000, 9000 and 12000 BTU Sizes

The Dry Air 25 system, a heat pipe, is a hermetically sealedheat transfer surface installed in a “saddlebag” configurationaround the indoor (evaporator) coil of the Zoneline. This coil

arrangement will transfer heat from the front coil of thesaddlebag to the rear coil without power consumption.This assembly uses R-22 as the refrigerant and is notconnected to the regular Zoneline refrigerant circuit.

As warm, humid air is pulled through the pre-cool (front)section of the heat pipe, the heat removed from the air isabsorbed by the refrigerant, causing the refrigerant to changeto a gas and flow to the re-heat (rear) section of the heatpipe. The air leaving the pre-cool section of the heat pipe iscooler and at a higher relative humidity level than the roomair. The pre-cooled air is further cooled as it passes throughthe evaporator; consequently, the relative humidity increasesallowing the evaporator coil to remove more moisture.

When the cold air from the evaporator comes in contactwith the re-heat section of the heat pipe, the heat that wasremoved by the pre-cool section is added back to the air andthe refrigerant in the heat pipe condenses and flows backto the indoor coil. The air discharged into the room by thisprocess is much drier, creating a more comfortable roomcondition.

The Newest Innovation from GE

The Dry Air 25 Models center around GE’s exclusive use of the patented Dinh® Dehumidifier Heat Pipe from Heat PipeTechnology, Inc. This innovative NASA spin-off technologyenables Dry Air 25 to remove 25% more moisture from theair than other leading manufacturers’ packaged terminal airconditioners. This helps maintain room comfort at a higherroom temperature, reducing operating costs.

The Dry Air 25 keeps a room cool and dry, and this is themost important benefit when it comes to the occupant of the room — hotel guests, apartment residents, students.

In a hot, humid climate, getting away from the humidityis just as important as the heat, and the Dry Air 25 is theperfect solution. The dehumidification of the Dry Air 25 hasbeen verified by the same ARI test conditions that standardunits are rated under. A list of customers using Dry Air 25 isavailable from GE.

COMPARISON OF DRY AIR 25 DEHUMIDIFICATION*

Removes

25%MoreMoisture

GE Dry Air 25

GE 2500 Series Zoneline®

Amana

Carrier

*Based on 12,000 BTU Units.

NOTE: The Dry Air 25 models include all features of the 2800 series.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 5/60

ge.com

Table of Contents

Front Cover 1

Mini Specs 2800, 800 and 5800 Series 2

Mini Specs Power Connection Kits and Nomenclature

The 2800/800/5800 and Dry 25 4

Table of Contents 5

Introduction 6

The Zoneline System 7

Features and Benefits

Features Table 8

Features and Benefits 9-11

Auxiliary Control Switches 12-1

Central Desk Control 14

Remote Thermostat Control 15-17

Heat Pumps and Energy Savings 18-19

Installation and DimensionsApplication Comments 20

Case Dimensions 21

Wall Case/Sub-Base Installation 22-

Condensate Disposal Systems 4-6

Ducted Installations 7-9

Exterior Grilles 40-41

Product Data

Electrical Connection 42

Essential Elements Ordering Overview 4

Maximum Connected Load 44

Cooling/Heat Pump Performance Data 45

Latent System Capacity 46

Normal Yearly Operating Data 47

Schematics 48-50

Product Specifications

Suggested Bid Form Specifications 51-5

Zoneline Chassis Nomenclature/Receptacles/Sub-bases 54

Specifications 55

Complete Accessory List 56

General Installation Suggestions 57-58

Warranty 58

Alphabetical Index 59

Back Cover 60

Important Notice

Equipment used as a primary source foheating or cooling is an integral part ofthe building in which it is installed. Prope

application is essential for satisfactoryperformance over a wide range of operating conditions. It is stronglyrecommended that a professionalengineer determine proper application

If this unit is a replacement unit, itsspecifications and performancemay differ from those of the unit it isreplacing. For that reason, we againstrongly recommend that a professionengineer determine proper application

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 6/606

Introduction

This manual is designed to provide product, performanceand application information to our customers and theirarchitects and engineers for use in selection and designof a zonal comfort control system utilizing GE Zoneline® Packaged Terminal Air Conditioners (PTAC) and PackagedTerminal Heat Pumps (PTHP). GE Zoneline PTACs and PTHPsare self-contained units designed for through-the-wall

installations in hotels, motels, apartments, hospitals,nursing homes, add-on rooms and many other installations.

Zonelines provide individual room or zone control in bothcooling and heating operation. There is a model for practicallyevery application, ranging in cooling capacity from 7,100 to14,700 BTUH and heating capacity from 6,400 to 1,400 BTUHin heat pump operation. See pages and 55 for resistanceheaters available.

Zoneline offers a two-tier lineup: the Deluxe Line and thePremium Line. The Deluxe Line consists of the 2800 Serieswith electric resistance heat, the 2800 Series Dry Air 25 Modelswith enhanced dehumidification for hot and humid climatesand the 800 Series heat pump. The 800 Series heat pumpfeatures reverse cycle defrost and simultaneous supplementalresistance heat, when needed, to maintain room comfort.The Premium Line features the 5800 Series heat pump withreverse cycle defrost and supplemental resistance heat, whenneeded, to maintain room comfort, plus tactile touch controlswith digital display and standard corrosion protection.

Deluxe Line Standard Features:• Universal Heaters

• 2 Fan Motors

• Heat Sentinel

• “L” Coil Design Condenser

• Locked-In-Place Control Knobs• -Position Vent Door

• Freeze Sentinel

• Indoor Coil Frost Control

• Central Desk Control Interface

• Remote Thermostat Control Interface

• Random Restart

• Electronic Temperature Limiting

• “Smart Fan” Fan Cycle/Continuous Control

• Transfer Fan Interface

• Room Occupancy Sensor Interface

• Reverse Cycle Defrost and Simultaneous SupplementalResistance Heat on Heat Pumps

• Quick Heat Recovery

Deluxe Line Optional Features:• Corrosion Protection

• Internal Condensate Removal (on 800 Series Heat Pumpwithout Corrosion Protection)

NOTE: Dry Air 25 models include all the standard features of the 2800 Series plusstandard corrosion protection.

Premium Line Standard Features:All the Standard Features of the Deluxe Line Plus:

• Two fan motor system with Indoor Cross Flow Blowerfor quieter operation

• Digital Controls

—LED Temperature Display

—Easy Temperature Selection

—Tactile Touch Pad

• Unit Diagnostics

• Standard Corrosion Protection Treatment

Premium Line Optional Features:• Internal Condensate Removal (Not for use in seacoast

or corrosive areas)

Advantages of the GE Zoneline System:• Flexible Application

—May be installed from flush to finished floor to " fromthe ceiling

—7,100 to 14,700 BTUH units in same physical size—Deluxe 2800 and 800 Series may be ducted to condition

more than one room

—Compatible with Class 2 remote thermostat control

—Compatible with 2 wire CDC or many EnergyManagement systems

• Economical Installation

—No ductwork necessary

—No mechanical equipment rooms or pipes required forheating/cooling units

—Replacement units fit existing 42"-wide by 16"-highwall cases

• Quiet Operation

—Indoor double cut-off scroll: two fan motor 2800 and 800Series units

—Indoor cross-flow blower: 2 fan motor 5800 Series units

• Energy-Saving Operation

—Units in unoccupied areas may be turned off 

—Designed for efficient cooling operation — EERs from 10.0to 1.0

—Efficient heat pump units — COPs from .2 to .6

—Extended heat pump operation without sacrificingroom comfort

• Ease of Maintenance—Permanently lubricated fan motors

—Upfront lift-out interchangeable filters

—Air Discharge area is easily accessed for cleaning

—Slide-out chassis for easy access for cleaning or if service is required

• Reverse Cycle Heat Pump Operation

Both the 800 and the 5800 Series heat pumps utilizethe unique GE PTAC heat pump operation to ensure acomfortable room. The logic used by the units is thesame logic used by central system heat pumps toprovide greater savings.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 7/60

ge.com

The Zoneline® System

The typical Zoneline installation consists of the wall case (or sleeve), chassis, and exterior grille. Some installations mayuse a sub-base for support of the unit or for ease of electrical connections. Each of the components should be the standardproducts offered by GE or, in the case of the exterior grille, approved by GE Applications Engineering. Use of components nospecifically designed or approved for use with the Zoneline can result in unsatisfactory operation and can be the cause of failure not covered by the warranty.

Components of the Zoneline SystemTypical Installation (Deluxe Series shown)

See pages 2 and for information on electrical sub-bases and chaseway.See pages 7-9 for information on ducted installations.

RAK601/602 (For Deluxe Series)Duct Extension, Register and Trim Flange

RAK6052 Duct Adapter(For Deluxe Series)

Wall CaseRAB71A (Steel-InsulatRAB77 (SMC — MoldedWall Case Options(See page 22)

RAG67 (showGrill Options(See page 40)

Room Cabinet

Chassis

Power Connection Kit (required on all units)

Line Cord Kit shownSee pages 42-4

Optional Accessories of the Zoneline System

RAK204D20P Sub-Base (shown)

Chaseway

Power Supply Cord (included with 208v/20vsub-bases)

Power Supply Cord

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 8/608

Zoneline® Features

AZ AZ AZ2800 800 5800

Enhanced Dehumidif ication — Dry Air 25 Optional N/A N/A

Cooling EER Range (20 Volts/265 Volts) 10.2 - 12.7 10.0 - 12.7 10.2 - 1.0

Heating COP Range (20 Volts/265 Volts) N/A .2 - .6 .2 - .6

Heat Source — Electric Resistance Heat Standard — —

Heat Source — Heat Pump With Selectable

Full Time or On Demand Simultaneous/Supplemental Resistance Heat — Standard Standard

Staged Heating — Stage Stage

Universal Heater — UPC* Standard Standard Standard

Unit Controls Rotary Knobs Rotary Knobs Touch Pad

Electronic Temperature Selection(Slews Up & Down) with Digital Display — — Standard

Unit Diagnostics — — Standard

Highly Featured Microprocessor Controls Standard Standard Standard-Plus

Electric Resistance Heat Lock-Out (above 46°F) — Standard Standard

Automatic Emergency Heat — Standard Standard

Heat Pump Defrost System — Reverse Cycle Reverse Cycle

High Temperature Operation Protection — Standard Standard

Quick Heat Recovery — Standard Standard

Temperature Boost Selectable Selectable

Service Indicator — — Temp Display Blinks

Fan Motors — Permanently Lubricated 2 2 2

2-Speed Outdoor Fan Standard Standard Standard

Indoor Fan Speed Selections — HIGH/LOW Standard Standard HIGH/LOW/AUTO

Fan Only Setting — HIGH/LOW Standard Standard Standard

Fan Cycle Switch “Smart Fan” “Smart Fan” “Smart Fan”

Constant-Run Fan Selectable Selectable Selectable

Rotary Compressor Standard Standard Standard

Automatic Compressor Restart Delay Standard Standard Standard

Freeze Sentinel™ Standard Standard Standard

Heat Sentinel Standard Standard Standard

Indoor Coil Frost Control Standard Standard Standard

Transfer Fan Connections Standard Standard Standard

7-Step Electronic Temperature Limiting Standard Standard Standard

Remote Control Capability with Wall Mounted Thermostat Standard Standard Standard

Central Desk Control Capability Standard Standard Standard

Energy Management System Interface with Load Shedding Option Standard Standard Standard

Reversible Indoor Air Louvers 40º/50º Standard Standard Standard

Up-Front Filters Standard Standard Standard

Easy-Clean Air Discharge Area Standard Standard —

Concealed Manual Vent Control Standard Standard Standard

Ducted Installation Capability RAK6052 RAK6052 —

Corrosion Protection (Standard on Dry Air 25) Optional Optional Standard

Internal Condensate Removal (ICR) (Factory Installed Option.Cannot be used in Corrosion Areas.) N/A Optional Optional*UPC — Universal Power Cord Connection (See pages 42 and 55).265-volt units must be connected in a manner to meet National Electrical Code and all local codes.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 9/60

ge.com

Features and Benefits

Standard Physical Dimensions

GE has maintained the same dimensions since 1961 —42" wide x 16" high x 1-/4" deep

Replacement of older units is made easy.

Weather-Protected Electrical Components

Vital electrical components are protected from the weather

by locating them on the indoor side of the weather barrier.

Weather-Resistant “Superseal”

Properly installed unit in undistorted case keeps air leakageto a minimum.

7 CFM air infiltration with 25 MPH wind on non-ICR units —10 CFM on units with ICR.

Industry specification is 19 CFM of air infiltration.

Heater Sizes to Meet Room Requirements

All units are equipped with a universal heater —the resistance heat output is determined by power

connection kit.20/208-volt — Line Cord Connected Units — 2.55/2.09 KWwith RAK15 — 15-amp circuit; .45/2.82 KW withRAK20 — 20-amp circuit; 5.0/4.09 KW with RAK0 —0-amp circuit.

20/208-volt - Sub-Base Connected Units — 2.55/2.09KW with RAK204D15P — 15-amp circuit; .45/2.82 KWwith RAK204D20P — 20-amp circuit; 5.0/4.09 KW withRAK204D0P — 0-amp circuit.

265-volt — 2.55 KW with RAK5172 — 15-amp circuit; .45 KWwith RAK5202 — 20-amp circuit; 5.0 KW with RAK502 —0-amp circuit.

Unit Controls

2800 and 800 Series — locked-in-place rotary knobs fortemperature and operation selection.

5800 Series — touch pad controls with digital readout of temperature set point.

Highly Featured Microprocessor Controls

Microprocessor controls are programmed to interface withthe temperature sensors to maximize comfort conditions forthe room occupant and provide outstanding features.

Thermistors are used to sense small changes in temperatureto give excellent room control and allow the microprocessorto monitor and react to changing conditions.

Electric Resistance Heat Lock-Out

To maximize the savings of the heat pump operation, theZoneline heat pumps do not utilize the resistance heaterwhen the outdoor temperature is above 46°F during normaloperation. The resistance heat is used in the Quick HeatRecovery feature.

Automatic Emergency Heat

Automatically uses electric resistance heat if the heatpump output is not suff icient to maintain selectedroom temperature.

Reverse Cycle Heat Pump Defrost System

Standard on all Zoneline 800 and 5800 Series heat pumps

Enables heat pump to operate at lower temperatureswhen other systems switch to more expensive electricresistance heat.

See pages 18 and 19 for discussion of heat pump operationand defrost systems.

High Temperature Heat Pump Operation Protection

Automatically protects the compressor if heat pump isoperated with high outdoor temperatures.

Power to the outdoor fan is turned off if the indoor coil getstoo hot during heat pump operation to prevent damage tothe compressor.

Quick Heat Recovery – Heat Pump Units

When the unit operation is changed from STOP or COOL toHEAT, the electric resistance heaters are used to warm theroom to the thermostat set point. This provides faster room

temperature increase for greater guest comfort.

Unit Diagnostics

The 5800 Series has a dip switch that activates each of the various components of the unit to operate briefly. Thisenables the technician to determine if individual componentare functioning properly.

Service Indicator

On the 5800 Series, if the microprocessor detects acompressor malfunction, the digital temperature displaywill blink. If the malfunction occurs during cooling operationthe indoor fan will continue to operate. If the compressor

malfunctions in heating mode, the unit will automaticallyswitch to resistance heat to maintain room temperature sepoint. GE Service should be called to check the Zoneline.

Fan Motors – Permanently Lubricated

All units have two fan motors for quiet operation andmaximum operating efficiency.

Motors are permanently lubricated to reduce maintenanceand totally enclosed to keep dirt and water out of the motowindings.

2-Speed Outdoor Fan

The unit automatically selects the most efficient speed for

the outdoor fan. The operating sound level is lower when thoutdoor fan can operate in low speed yet there are situationwhere it must operate in high speed. The unit changes thefan speed automatically.

Indoor Fan Speed Selections – HIGH/LOW

Unit may be operated in HIGH HEAT or LOW HEAT or HIGHCOOL or LOW COOL.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 10/6010

Features and Benefits

Fan-Only Setting – HIGH/LOW

The unit provides the option of selecting either HIGH or LOWspeed for Fan-Only operation.

Fan-Cycle Switch – “SmartFan”

Unique “SmartFan” allows unit to operate fan continuous incooling operation and fan cycle in heating to provide better

guest comfort. Eliminates complaint of cold air draft duringheating operation.

Eliminates need of changing fan-cycle switch seasonally.

“SmartFan” settings are controlled by two dip switches onauxiliary control panel.

Compressor Random Restart

In the event of a power failure, all compressors attemptingto restart immediately when power is restored can resultin a power surge that can cause another power interruption.

The microprocessors in the Zonelines have a random restartlogic system that prevents all units from starting at the

same time.

Rotary Compressor

Smoother operation for quiet, dependable service. GE hasused rotary compressors since 1961.

Compressor Restart Delay

Zonelines are designed to provide a minimum of threeminutes of compressor off time to allow refrigerant pressuresto equalize before restarting to prevent compressor damage.

Zonelines are also designed to provide a minimum of threeminutes of compressor run time to prevent room occupantdisturbance due to short-cycling of the air conditioner.

Freeze Sentinel™

Detects low room temperature and turns on heater tohelp protect against damage caused by freezing roomtemperature.

Heater turns on at 41°F and warms indoor thermistortemperature to 46°F and shuts off.

Freeze Sentinel may be turned off by dip switch onauxiliary control.

Heat Sentinel

The property owner may choose to activate the Heat

Sentinel feature on the Zoneline. If the Heat Sentinel isactivated and room temperature reaches 85°F while theunit is in the “STOP” setting, the unit will automatically startin air conditioning operation and will shut off when the roomtemperature reaches 80°F. This will help dehumidify the airand lower high temperatures so the guest will not be enteringan extremely hot room.

Indoor Coil Frost Control

Prevents indoor coil from freezingand causing complaints due to lackof cooling. Frost can form on theindoor coil when the unit is operatedin cooling when outdoor temperaturesare low. The unit automatically shuts

the compressor off until the indoor coiltemperature warms to the point wherefrosting will no longer occur.

Transfer Fan Interface

24 VAC terminals are provided to operate a relay to controla fan mounted in a wall to move conditioned air intoanother space. The electrical power for the operation of thetransfer fan itself is not provided by the Zoneline. Transferfans and their controlling relays are field supplied.

Electronic Temperature Limiting

Seven independent programmable heating temperature limits

and seven independent programmable cooling temperaturelimits. Eliminates need to reset the limits seasonally.

Remote Control Capability with Wall-MountedThermostat

See pages 15-17.

Central Desk Control Capability

See page 14.

Energy Management System Interface withLoad Shedding Option

All units have a switch on the auxiliary control panel toallow the indoor fan to continue operating if the unit is

connected to an Energy Management System that shutsoff compressor or heater operation. By allowing the indoorfan to run when the heater or compressor is shut off bythe Energy Management System, the guest is less likely torealize the operation of the unit has been altered. This helpsreduce peak energy demand loads without disturbing theroom occupant.

Reversible Indoor Air Louvers

Allows air to be directed into room at 40º or 50º angle toprovide better air distribution.

Angle is changed by removing room front and screwsholding louver in place, and rotating louver section.

Heating Temperature LimitsHighest

Heat

65 70 72 74 76 78 80 85

LowestCool

Cooling Temperature Limits

60 64 66 68 70 72 74 76

Limits are set by dip switches on auxiliary control panel.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 11/601

ge.com

Features and Benefits

Up-Front Air Filters

Two interchangeableup-front filters, easyto remove and reinstall,may be cleaned withoutopening or removingthe room front.

Clean filters by brushing,vacuuming or back-flushing under faucetor shower head.

Easy Clean Air Discharge Area

2800 and 800 Series units have an out-of-sight verticalprotective screen over the indoor fan. This allows easycleaning of air discharge area by simply removing roomfront and wiping clean.

There is no screen directly below discharge louver to trapunsightly dirt and debris where it may be seen by room

occupant.Concealed ManualVent Control

The -position manual ventdoor control may be closed,partially open or fully open.

Vent CFM High SpeedUnit Full Open Partial Open

7000 50 40

9000 70 45

12000 75 45

15000 75 45

CFM ratings at 20 volts and 265 volts.

Greater amounts of air will be introduced if the room has anexhaust fan.

An open vent door brings unconditioned outdoor air into theroom, increasing heating and cooling costs.

Positive vent door closure prevents accidental opening andunwanted air infiltration.

Corrosion Protection (Optional)

2800 and 800 Series units may be ordered with specialprotection to better withstand damage from salt air andsalt water in seacoast areas.

Corrosion protection is standard on the 5800 Series andon Dry Air 25 models.

Heat Pump units with ICR are not available with corrosionprotection and should not be installed in seacoast orcorrosive environments.

Units installed in corrosive areas should be examined andcleaned more frequently than normal installations.

Internal Condensate Removal (ICR)

See page 4 for a discussion of the Internal CondensateRemoval system available on 800 and 5800 Series heat pump

Enhanced Dehumidification

Moisture removal is an important function of an airconditioner. People are more comfortable at higher

temperatures when the humidity level is relatively low.Air conditioners operate with less energy consumptionwhen the room temperatures are set higher.

The GE Zoneline® 2800 Series with the Dry Air 25 heat pipeapplication removes 25% more moisture than the base2800 Series unit.

The GE Zoneline Dry Air 25 chassis is the only PTAC availablwith the application of the patented Dinh® DehumidifierHeat Pipe under license from Heat Pipe Technology, Inc.

Customers who are using the Dry Air 25 report a fresher-smelling room as a result of the lower humidity levels, aswell as lower operating costs.

Locking Door Kit

RAK802 — A door with a lock that replaces the standardcontrol cover door to prevent unauthorized changing of control setting is offered as an accessory.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 12/6012

Auxiliary Control Switches

These switches are located behind the room cabinet under the control panel.

2800 and 800 Series Switches Description

 Left Switches

(1) ALL I2R Heat pump override —Down — Normal heat pump operationUp — resistance heat only (800 Series only)

(2) C: FAN Fan control for cooling operation —Down — Fan ContinuousUp — Fan Cycle

() H: FAN Fan control for heating operation —Down — Fan CycleUp — Fan Continuous

(4) CLASS 2 Remote Thermostat Mode —Down — Unit ControlUp — Remote Thermostat

(5) LOAD SHED Load Shedding when connected to Central Desk Control System —Down — Fan shuts off with unitUp — Fan under “Smart Fan” settings

(6) FREEZ S Freeze Sentinel™ Override —

Down — Freeze Sentinel ONUp — Freeze Sentinel OFF

(7) CONST FAN Constant Fan —Down — Fan runs normallyUp — Fan runs when unit is in STOP position

(8) OCCUPIED Occupancy Sensor Mode —Down – Unit ControlUp — Occupancy Sensor Connected

Right Switches

 TL1 – TL Cooling temperature limiting (See table at bottom of page)

TL4 – TL6 Heating temperature limiting (See table at bottom of page)

(7) Heat Sentinel switch —Down — Heat Sentinel OFFUp — Heat Sentinel ON

(8) Heat Boost (800 series only) —Down — Heat Boost OFUp — Heat Boost ON

Auxiliary (2800 and 800 series)

HIGHCOOL1 2 3 4 5 6 1 2 3 4 5 67 8

UPDOWN

UPDOWN

ALLI2R (All Electric Heat)

(3800 Series models only)

C: FAN CN (Cooling–Smart Fan)

H: FAN CY (Heating–Smart Fan)

CLASS 2 (Remote Thermostat)

LOAD SHEDDING (CDC)

FREEZ Sen (Freeze Sentinel)

CONST FAN (Constant ON Fan)

OCCUPIED (Occupancy Sensor)

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)TL3 (H) (Temp. Limit 3–Heat)

TL1 (C) (Temp. Limit 1–Cool)TL2 (C) (Temp. Limit 2–Cool)TL3 (C) (Temp. Limit 3–Cool)

7 8

Heat Sentinel

HEAT BOOST(3800 Series models only)

Cooling and Heating temperature limits are set independently, temperature limitingswitches are in factory-set down position, except as noted.

Cooling Temperature Limits

Switches Up NONE 1 1, 2 2 2, 1, 2, 1,

60 64 66 68 70 72 74 76

Heating Temperature Limits

Switches Up 6 4, 6 4, 5, 6 5, 6 5 4, 5 4 NONE

65 70 72 74 76 78 80 85

800 Series shown

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 13/601

ge.com

Auxiliary Control Switches

These switches are located behind the room cabinet under the control panel.

5800 Series Switches Description

 Left Switches

(1) ALL I2R Heat pump override —Down — Normal heat pump operationUp — resistance heat only

(2) C: FAN Fan control for cooling operation —Down — Fan ContinuousUp — Fan Cycle

() H: FAN Fan control for heating operation —Down — Fan CycleUp — Fan Continuous

(4) CLASS 2 Remote Thermostat Mode —Down — Unit ControlUp — Remote Thermostat

(5) LOAD SHED Load Shedding when connected to Central Desk Control System —Down — Fan shuts off with unitUp — fan under “Smart Fan” settings

(6) FREEZ S Freeze Sentinel Override —

Down — Freeze Sentinel ONUp — Freeze Sentinel OFF

(7) CONST FAN Constant Fan —Down — Fan runs normallyUp — fan runs when unit is in STOP position

(8) OCCUPIED Occupancy Sensor Mode —Down — Unit ControlUp — Occupancy Sensor Connected

 Right Switches

 TL1 – TL Cooling temperature limiting (See table at bottom of page)

TL4 – TL6 Heating temperature limiting (See table at bottom of page)

(7) Diagnostics Switch

(8) Heat Sentinel switch —Down — Heat Sentinel OFFUp — Heat Sentinel ON

(9) Heat Boost —Down — Heat Boost OFFUp — Heat Boost ON

Cooling and Heating temperature limits are set independently, temperature limitingswitches are in factory-set down position, except as noted.

Cooling Temperature Limits

Switches Up NONE 1 1, 2 2 2, 1, 2, 1,

60 64 66 68 70 72 74 76

Heating Temperature Limits

Switches Up 6 4, 6 4, 5, 6 5, 6 5 4, 5 4 NONE

65 70 72 74 76 78 80 85

HIGHCOOL1 2 3 4 5 6 1 2 3 4 5 67 8

UPDOWN

UPDOWN

ALLI2R (All Electric Heat)

(5800 Series models only)

C: FAN CN (Cooling–Smart Fan)

H: FAN CY (Heating–Smart Fan)

CLASS 2 (Remote Thermostat)

LOAD SHEDDING (CDC)

FREEZ Sen (Freeze Sentinel)

CONST FAN (Constant ON Fan)

OCCUPIED (Occupancy Sensor)

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)TL3 (H) (Temp. Limit 3–Heat)

TL1 (C) (Temp. Limit 1–Cool)

TL2 (C) (Temp. Limit 2–Cool)TL3 (C) (Temp. Limit 3–Cool)

7 8 9

Diagnostics Switch

HEAT BOOST(5800 Series models only)

Heat Sentinel

5800 Series shown

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 14/6014

Central Desk Control

Some installations may want to govern the ability of the unitto operate from a control device remote to the unit or evenremote to the room in which the unit is located. The generalterm given to systems such as this is Central Desk Control.The most common installation of this type of system is aswitch mounted at the registration desk and, upon guestcheck-in, a button is pushed or a switch is moved to allow

the air conditioner to operate. Likewise, when the guestchecks out the device is put into the “OFF” position so theunit will not operate while the room is vacant.

It is not necessary that the controlling device be locatedat a central desk to employ a device that will control theunit operation. For instance, in some resort areas devicesare connected to sliding glass doors and opening the doorcauses a contact to close, turning the air conditioner off.This prevents energy being wasted by operating the airconditioner when warm, humid air is entering the room.Some systems operate by motion sensors or heat sensingdetectors mounted in the room. These types of systemsdetermine occupant presence in the room and allow the

unit to operate; if no one is in the room the device signalsthe air conditioner to turn off.

Zoneline® models offer Load-Shedding capabilities onunits connected to Central Desk Control Systems. For moreinformation on the models’ Load-Shedding Feature, seepage 10.

There is a wide variety of devices available, each withits own benefits and constraints. While GE does not offercomponents that are external to the unit for a Central DeskControl (CDC) system, GE Zonelines are compatible with mostCDC and Energy Management systems. Zonelines provide a24 VAC circuit that powers the Central Desk Control system

and no external power is needed.All Zoneline 2800, 800, and 5800 Series units are compatiblewith simple on/off 2-wire Central Desk Control systems.Consult with the provider of other energy managementsystems to be sure they are compatible with the GE Zoneline.Zonelines have standard connectors factory-installed toprovide a CDC interface that permits the unit to be connectedto most of the energy management systems. The devicesconnected to the Zoneline units require no power supply ortransformers external to the unit.

Important CDC Comments (all series applicable)

1. When the switching device closes the circuit of the CDC

conductors, the unit operation stops.

2. Do not use a common buss (at the unit or at the switchpanel) in the wiring. Both wires comprising the circuit mustconnect to the unit connectors and to the controllingswitch. Running one wire from one unit to another unit iscommon bussing and may damage internal componentsor cause erratic operation of the system.

. A 24-volt transformer is contained within the Zoneline.No external voltage may be applied to the unit throughthe CDC terminals. (Voltage on the CDC conductors is24 volts AC.)

4. Recommended wire size must be followed as a minimumrequirement.

Wire Size #AWG Maximum Allowable Length

#22 600 Ft.

#20 900 Ft.

#18 1500 Ft.

#16 2000 Ft.Freeze Sentinel™ remains operational when the unit isconnected to a CDC system. Even if the unit is turned “OFF” atthe central location, if the sensor at the unit detects the lowtemperature, the electric resistance heaters and the fan willautomatically turn on.

Connecting the Zoneline to a CDC system does not eliminatethe ability to connect the unit to a remote thermostat.Once the circuit is “opened,” and control of the unit removedfrom the CDC system, the selected controls - either the unitmounted control or the remote thermostat - govern theoperation of the unit.

Please see page 57 for installation recommendations forthe Central Desk Control wiring.

CDC Terminal Location and Typical Wiring

See page 15 for location of CDC terminals on unit.

Unit #2Unit #1 Unit #3

Example of Common Bussing

NOT PERMITTED

CDCTerminals

onZoneline

INCORRECT Common Bussing

Normally Open

Switch -

Unit Operational

Typical Wiring

(All Wiring Shown Is Field Supplied)

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 15/601

ge.com

The AC voltage may not be compatible with somesolid-state thermostats.

The fan speed for the 2800 Series in remote thermostatoperation is selected by the connection of the fan wire fromthe thermostat to either the HIGH or LOW terminal on the uniSee the sketch of the unit terminals for the location of the HIGand LOW fan-speed terminals. Operating the unit in low fan

speed reduces the operating sound level of the unit.Freeze Sentinel™ remains operational if the unit is connected ta remote thermostat. The unit may be connected to a CentraDesk Control (CDC) system and controlled with a remotethermostat when the CDC system has the unit in operation.See page 14 for additional information on the CDC system.

Unit temperature limiting switches are not functional whenunit is connected to a remote thermostat.

Field Wiring TerminalR — 24V ACGL — Low-Speed FanGH — High-Speed Fan

B — Not Used on 2800Y — CompressorW — HeaterC — Common — Ground

Remote Thermostat Control

In some installations, control of the operation of the unit ata location remote from the unit itself may be desired. A unitmounted high in the wall or over a door, for instance, wherethe unit-mounted controls are inaccessible, can be connectedto a wall-mounted thermostat. Other installations may useremote thermostat control for design or performanceenhancement. The unit is connected to the thermostat by

low-voltage wiring which permits the operation of the unit tobe selected and the temperature sensed at the thermostat.

Important Notes: Remote thermostat wiring should not berun through wall case. Thermostat wiring should exit thewall below the unit and enter the unit between room cabinetand chassis. Wire molding may be used to hide thermostatwiring. If a sub-base is used, the thermostat wiring may beconcealed by the sub-base. Thermostat wiring should not berun parallel to line voltage wires since induced current maycause erratic operation.

All Zoneline 2800, 800 and 5800 Series units are adaptableto Class 2 remote low-voltage thermostat. The only additionalfield-supplied components are the remote thermostat andwiring necessary to connect it.

The controls on the unit are not functional when the remotecontrol function is used.

Resistance Heat Models

The Zoneline 2800 resistance heat units may be connected toa single-stage thermostat designed for use with cooling withelectric heat systems. GE offers three thermostatscompatible with the 2800 Series unit.

    R     G    L

     G    H B Y W C

Common — Ground

White — Heater

Yellow — Compressor

Black — Not Used On 2800

Green — High-Speed Fan

Green — Low-Speed Fan

Red — 24V AC

CDC Terminal

 

     C    D

     C

RAK16A1 —a mechanicalmanualchangeoverthermostatrequiring fourconnection wires.

RAK164D1 —a solid-statedigital manualchangeoverthermostatrequiring fiveconnection wires.

RAK164P1 —a solid-state digitalprogrammableauto-changeoverthermostatrequiring fiveconnection wires.

The Class 2 Mode Switch (dip switch #4 on the auxiliary controlboard) must be set to the ON/UP mode to enable remotethermostat control. Refer to installation instructions packagedwith the chassis.

Please see page 57 for installation recommendations forthe remote thermostat wiring.

Compatibility of other thermostats considered for use with theGE Zoneline is the responsibility of the customer. The controlvoltage on the remote control conductors is 24 volts AC.

RAK806 Universal Control Cover Label

When a Zoneline unitis using a remotethermostat control,the RAK806 Universal

Control Cover Labelis recommended. TheRAK806 is onlyavailable in apackage of 10 labels.The label is placedover the controlpanel directing theuser to the wallthermostat foroperation of theZoneline unit.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 16/6016

Remote Thermostat Control

Heat Pump ModelsThe Zoneline® 800 and 5800 Series heat pump units maybe connected to a single-stage cooling/two-stage heatingthermostat designed for use with heat pump systems. GEoffers thermostats compatible with the 800 and 5800series units:

RAK147 —mechanicalmanualchangeoverthermostatrequiring 6connection wires.

RAK148D1 —solid-state digitalmanualchangeoverthermostatrequiring 6connection wires.

RAK148P1 —solid-state digitalprogrammableauto-changeoverthermostatrequiring 6connection wires.

Please see page 57 for installation recommendations for theremote thermostat wiring. Compatibility of other thermostatsconsidered for use with the GE Zoneline® is the responsibilityof the customer.

The control voltage on the remote control conductors is 24 VAC.

The Class 2 Mode Switch, dip switch #4 on the auxiliary controlboard on both the 800 series and the 5800 series, must be setto the ON/UP mode to enable remote thermostat control. Referto installation instructions packaged with the chassis.

The fan speed for the 800 and 5800 series in remotethermostat operation is selected by the connection of thefan wire from the thermostat to either the HIGH or LOWterminal on the unit. See the sketch of the unit terminals

for the location of the HIGH and LOW fan speed terminals.Operating the unit in low fan speed reduces the operatingsound level of the unit.

When connected to a remote thermostat, the indoor airtemperature sensing is shifted from the unit to the remotethermostat. For this reason, the units will operate slightlydifferently when connected to a remote thermostat. Thefollowing chart shows the unit operation when connectedto a remote thermostat.

Field Wiring TerminalR — 24V AC GL — Low-Speed FanGH — High-Speed Fan B — Reversing ValveY — Compressor W — HeaterC — Common - Ground

Zoneline Series Thermostat Model Type Function Low-Voltage Conductors

2800 RAK16A1 Mechanical

Cooling and Heating

4

RAK164D1 Digital 5

RAK164P1 Digital Programmable 5

800 and 5800 RAK147 MechanicalSingle Stage Cooling –

2 Stage Heating

6

RAK148D1 Digital 6

RAK148P1 Digital Programmable 6

Thermostat wire size – up to 60 feet AWG20 – up to 66 feet AWG18

Remote Thermostat Control Selection Chart For Zoneline Packaged Terminal Units

 

    R     G    L

     G    H B Y W C

Common — Ground

White — Heater

Yellow — Compressor

Black — Reversing Valve

Green — High-Speed Fan

Green — Low-Speed Fan

Red — 24V AC

 

Temperature Boost option should not be used with remotethermostat operation since this will cause the unit to switch toresistance heat when outdoor temperatures are below 46ºF.

Feature Heat Pump Electric Heat

Indoor Frost Control Yes Yes

Freeze Sentinel Yes Yes

Auto Fan Speed No NoElectronicTemperature Limiting No No

Switch to ResistanceHeat Based On IndoorTemperature

Determined byRemote Thermostat N/A

Switch to ResistanceHeat Based OnOutdoor Temperature Yes N/A

Reverse Cycle Defrost Yes N/A

SimultaneousResistance Heatwith Heat Pump No N/A

Resistance HeatLockout Yes N/A

“Smart Fan”Fan Cycle

Fan ON/AUTO Set OnRemote Thermostat

Fan ON/AUTO Set OnRemote Thermostat

Central Desk Control Yes Yes

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 17/60

ge.com

Remote Thermostat Control

Multiple Units Connected to One Remote Thermostat(2800 Series)

One remote control thermostat may be used to controlmultiple resistance heat Zoneline units, however the unitsmay not be wired direct. Since each Zoneline unit has an

integral transformer, direct wiring can result in a “bucking”or boosting” voltage condition, and is in violation of theNational Electric Code. The diagram below shows thecorrect wiring for such an installation through the useof field supplied isolation relays.

For Use With Mechanical 4-Wire Systems Only

Remote Control (Low Voltage) Wiring

One stage Thermostat Controlling Three Zoneline UnitsResistance Heat Zoneline 2800 Series Units(Not Applicable on Heat Pump Units)

Number Of Units Controlled

Relay DesignationR1, R2, And R

2 POTTER and BRUMFIELD TYPE KA11AY-24 OR EQUIVALENT

POTTER and BRUMFIELD TYPE KA14AY-24* OR EQUIVALENT

4 POTTER and BRUMFIELD TYPE KU17A11-24* OR EQUIVALENT

MORE THAN 4 USE COMBINATION OF RELAYS SPECIFIED ABOVENOTE: Current draw through thermostat contacts should not exceed 1.0 amps.*Special order, 100 piece minimum order.

Field-Supplied Relay Specifications

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 18/6018

Heat Pumps and Energy Savings

• GE Zoneline® Heat Pumps are designed to providecost-efficient heat pump operation while monitoringroom conditions to maintain comfort.

The units employ a logic system monitoring both outdoorand indoor temperatures to determine the heat source, thusincreasing energy savings by operating longer in the heatpump mode.

Heat pumps save energy and cost less to operate thanunits with electric resistance heaters as the only heat source.Just as the EER of an air conditioner is an indication of theefficiency of the unit, COP (Coefficient of Performance) is theindication of the efficiency of the heat pump. This relativeefficiency of a heat pump compares the unit to electricresistance heat. If a unit has a COP of .0, it means theunit will produce three times as much heat at ratingconditions for the same electrical input wattage usedfor electric resistance heat.

The compressor is used in heat pump operation just asin air conditioning operation. In heat pump operation,the hot refrigerant gas is directed to the indoor coil rather

than to the outdoor coil. Room air that circulates over theindoor coil gains heat from the coil rather than losing heatto the coil as during cooling operation.

As the outdoor temperature falls, the heat pump is able toextract less heat from the outdoor air to raise the temperatureof the indoor air. For this reason, all packaged terminal heatpumps also have electric resistance heaters as backup to heatpump operation. At some point, the heat pump is unable toprovide sufficient heat to adequately warm the room. ManyPackaged Terminal Heat Pumps cease heat pump operationand change to more expensive resistance heat at somepre-determined outdoor temperature to compensate forthe inability of the heat pump to maintain room temperature.

This point, called the “switchover point,” is usually at anoutdoor temperature where savings from heat pumpoperation may still be realized, if the unit is designed tomaintain room comfort at the lower outdoor temperatures.

Balance PointAn important consideration of the selection of a heat pumpunit is the “balance point” of the installation. Virtually everyroom is unique — with different insulation — different sizesand types of windows — different types of construction— different directional exposures. All of these variables, aswell as geographical location, must be considered in order to

determine the balance point, the point at which the heat pumpis unable to produce enough heat to compensate for the heatloss of the room or area being heated. For these reasons aconsulting engineer should be engaged to calculate the heatloss and specify the heat pump unit required.

GE offers two series of Zoneline Heat Pump units — the800 Series with Standard Microprocessor controls and the5800 Series with Highly Featured Microprocessor controls— and both series react to the indoor temperature as wellas the outdoor temperature in determining the heat sourceto provide comfortable room conditions and energy savings.This determination of the heat source based on the indoortemperature helps provide a more comfortable room.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 19/601

ge.com

Heat Pumps and Energy Savings

Heat Pump Operation —Zoneline 800 and 5800 Series

Heat sources: Heat pump, heat pump and simultaneouselectric resistance heat or electric resistance heat.

Zoneline heat pumps employ a highly featured microprocessorcontrol system interfaced with thermistors to accuratelymeasure indoor air temperature, outdoor air temperature,indoor coil temperature and outdoor coil temperature. Thissystem allows the microprocessor to precisely and predictablyreact to changing conditions in order to provide a veryadvanced Packaged Terminal Heat Pump operating system.

The Zoneline heat pumps are designed to help ensure acomfortable room. When “HEAT” is selected, the unit willdetermine if the room air is warm enough to satisfy thethermostat setting. If the temperature at the unit sensoris below the desired temperature, the electric resistanceheater will be utilized to warm the room to the point wherethe thermostat is satisfied. This feature is designed to allowthe temperature of an unoccupied room to be maintained

at an energy-saving level without inconveniencing the roomoccupant. Once the thermostat has been satisfied, theresistance heater will turn off and the heat pump will operateas shown in the Heat Source Logic chart until the thermostatcalls for heat again. The unit will operate in this manner evenif connected to a Central Desk Control.

 

ROOM

TEMPERATURE

VS. THERMOSTAT

SET POINT

Above

46°F

Between 46°F

and 25°F

Below

25°F

Less Than

1.8°F Below Heat Pump Heat Pump*Full Resistance

Heat

1.8°F to 2.7°F

BelowHeat Pump

Heat Pump +

Supplemental

Heater

Full Resistance

Heat

More than 2.7°F

BelowHeat Pump

Full Resistance

Heat

Full Resistance

Heat

Zoneline Heat Pump Heat Source Logic

*If the “Temperature Boost” switch (dip switch #8) is inthe “ON” position the supplemental simultaneous heaterwill be used with heat pump operation. Simultaneoussupplemental heater: 1.0 KW @ 20 V; 0.8 KW @ 208V; 1.0KW @ 265V.

The “Temperature Boost” option utilizes the supplementalsimultaneous heater simultaneously with heat pumpoperation when the outdoor temperature is below 46°Fregardless of the indoor air temperature. The chart aboveindicates the heat source of the heat pump under variousindoor and outdoor conditions. The unit is designed toprovide heat pump savings without sacrificing room comfort.

The Quick Heat Recovery feature is not affected by the HeaSource Logic shown in the chart above. For more informatioabout the Quick Heat Recovery Feature, see page 9. Thefull heat output of the resistance heater is dependent uponcircuit amperage and the power connection kit used. Seepages and 42-4 for information on power connection kitand available heater capacities.

A heat pump switch is provided in the auxiliary controls toallow the unit to operate only in resistance heat. The use ofthis option significantly increases the cost for heating.

Heat pump defrost — Zoneline 800 and 5800 Series

Zoneline heat pumps utilize a reverse-cycle demand defrossystem to extend heat pump operation and increasesavings from extended operation. The microprocessordetermines the need for defrosting by criteria basedon continuous compressor running time, outdoor airtemperature, outdoor coil temperature and the rate of temperature change of the outdoor coil. When defrostingis required, the unit reverses the flow of refrigerant to direc

the hot gas into the outdoor coil to melt the frost build-up.Before and after the reverse-cycle defrosting, the unit shutsoff the compressor to allow the refrigerant pressuresto equalize throughout the system. This eliminates thepossibility of a loud reversing noise. During these periodsof pressure equalization, the full resistance heat capacityof the unit is activated to help ensure room comfortconditions during the defrost cycle. The unit remains inthe defrost cycle for a minimum of two minutes up to amaximum of nine minutes. The defrost cycle terminateswhen the outdoor coil reaches a temperature of 68°F or themaximum time has been reached.

Heat pump condensateSee page 4 for information on heat pump condensate.The Zoneline 800 Series heat pumps may be ordered witha factory-installed Internal Condensate Removal (ICR) systemto minimize the amount of condensate water draining fromthe unit during heat pump operation. The ICR system hasproven to be an effective means of minimizing the amount oheat pump condensate dripping from the unit. However, if threquirements of a particular installation will allow no drippinof condensate water from the wall case, the installation of ainternal or external drain system is recommended.

Units with ICR may not be installed in seacoast or corrosiveenvironment applications.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 20/6020

High Wall Mount — For unitsmounted high in the wall, thedischarge louvers should beat a setting that provides themost horizontal air discharge.Recommended installation isat least " below the ceiling.

In installations where unitsare close to the ceiling, themost horizontal dischargeangle can be obtained byremoving the discharge grillfrom the room cabinet.

Supply Air Throw — OneZoneline unit should not berequired to do a job obviouslyrequiring two or more units.Units should be located aroundlarge rooms according tocalculated loads or in such

fashion as to achieve balancedair distribution in all parts of the room. The single unit inthe “Incorrect” illustrationbelow obviously cannotcondition the entire room.Add a second unit as shownin the “Correct” illustration.

Application Comments

Use and Care Manual and installation instructions areshipped with Zoneline® units. It is important that any airconditioning system be properly sized and applied in orderto achieve the desired temperature and humidity levels withthe space to be conditioned. Air conditioners are designedprimarily to provide heating and cooling with the additionalbenefit that during operation in the cooling mode, the units

also remove some moisture from the conditioned space.The following are some brief application comments onundersizing, oversizing, heating, wall coverings, and airinfiltration: all are important in the proper matching of theheating/air conditioning system to the building structure.

Undersizing: If an air conditioner is undersized (coolingcapacity is less than required for a specific application), theunit will typically not be able to cool the space down to thedesired temperature (thermostat set point), nor be able toremove enough moisture from the air. A result could be awarm and humid or warm and dry conditioned space.

Oversizing: If an air conditioner is oversized (cooling capacityis greater than required for the specific application), the unitwill typically cool the space down to the desired temperature(thermostat set point) too quickly. The compressor thenbegins to cycle on and off. Dehumidification only takes placewhen the compressor is operating. A typical result in a hot/humid climate could be a cool but excessively humid space.

Heating: Undersizing can result in not being able to maintainthe desired temperature level within the conditioned space.

Wall Covering: Use of a non-permeable wall covering (somepaints, some wallpapers, and other types of coverings) whichseverely restricts passage of air or water vapor can cause asevere moisture problem. Typical results could be staining of room surfaces, wall damage, as well as mold and mildew

growth in hot/humid climates.

Air Infiltration: Excessive air infiltration can magnifyproblems associated with undersizing or oversizing of anair conditioner unit and can be the root cause of insufficientcooling, dehumidification, or heating. Some sources of airinfiltration include vents, gaps around windows and doors,and improperly sealed floor, ceiling and wall joints.

Recommendation: For the above reasons it is stronglyrecommended that a professional engineer be retainedto match the Zoneline unit with the building structure.

Air Distribution

Zoneline packaged terminal air conditioners and heat pumpsdischarge air from the top of the unit through reversible2-position discharge louvers. Unit discharge louvers arereversed by removing the room cabinet from the unit,removing seven screws that hold the louver section inplace, removing the louver section and rotating it end forend, reinstalling the louver section in the room cabinet withthe seven screws, and reinstalling the room cabinet on theunit. The unit is shipped from the factory with the dischargelouvers at an angle of 50° off vertical. In the alternateposition, the louvers will be at an angle of 40° off vertical.

All room cabinets return air through the front of the unit.

50°

40°

OVER 40 FT.

INCORRECT

OVER40FT.

CORRECT

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 21/602

ge.com

Dimensions

RAB71A WALL CASE

WALL OPENING16-1/4" MIN. x 42-1/4" MIN.

RAB77 WALL CASE

WALL OPENING16-1/2" MIN. x 42-/8" MIN.

WALL CASE WITHCHASSIS INSTALLED

WALL CASE WITHSUB-BASE

*SHOWN WITH ACCESS COVERS REMOVED.NOTE: CAUTION - REMOVE KNOCKOUTS FROM INSIDE OUT.

Installation Instructions Packed With Wall Case . . . See Page 25 For Additional Information Concerning OutdoorWeather Panel and Case Stiffener.

AdditionalWall Case DepthsRAB7116 - 16"RAB7124 - 24"RAB7128 - 28"RAB711 - 1"

42"

  1  3 -

  3 / 4  "

16"

1-1/2" TYP 1/2"

6"

21"

36"

A1/2" SQ. HOLE (2 REQ'D.)

1/2" DIA.HOLE (3 REQ'D.)

2-3/4"

5-5/8"

4"

6"

19"

36"

16-1/4"

13-7/8"

1-1/2"

42-1/8"

1/2" SQ. HOLE(2 REQ'D.)

9/16"

2-7/8"

5-5/8"

4"

1/2" DIA.(3 REQ'D.)

RAB71 = 42"RAB77 = 42-1/8"

RAB71 = 13-3/4"RAB77 = 13-7/8"

42"

TOP VIEW

GRILLE

ROOMCABINET

INSIDE

ROOMCABINET

SIDEVIEW

RAB71 = 20-7/8"RAB77 = 21"

OUTSIDE

RAB71 = 16"RAB77 = 16-1/4"

GRILLE

7-1/8"

FRONT VIEW*

3-1/2" 12-3/4" 12" 9-3/8" 2-1/2"

1-7/16"

LEVELING SCREWKNOCKOUTS (ENCLOSURE)

4 REAR; 4 BOTTOM

SEE PAGE 32 FOR KNOCKOUT LOCATION DIMENSIONS.

1-5/16" 2-3/8" MIN.

INTERIOR

WALL

3" MIN.ADJUSTABLETO 5" MAX.

FINISHED FLOOR

SIDE VIEW

13"

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 22/6022

Wall Case

A choice of wall cases is available for the Zoneline.®

RAB71A — This insulated case is constructed of heavy-gaugegalvanized steel and finished with a protective baked-enamelfinish for protection and appearance. Design of the caseprovides for support of the chassis and free draining of anywater entering the wall case. A petroleum microcrystallinewax is applied at critical points of fabrication to seal against

moisture. The dimensions of the RAB71 wall case are: 42"wide by 16" high by 1-/4" deep, the same dimensions as theoriginal wall case for GE Zonelines built in 1961. The RAB71wall case is also available in depths other than the standarddepth. It is available on special order as: RAB7116 – 16" deep;RAB7124 – 24" deep; RAB7128 – 28" deep; and RAB711 – 1"deep. All of these special-order deep wall cases are insulatedand have sheet metal dividers, or splitters, to prevent therecirculation of condenser discharge air.

RAB77 — This non-insulated wall case is molded fromfiberglass-reinforced polyester compound. This SMC(Sheet-Molded Compound) wall case offers outstandingstrength, durability, color retention, water integrity andcorrosion resistance. The dimensions of the RAB77 wallcase are: 42-1/8" wide by 16-1/4" high by 1-7/8" deep.

• Both wall cases are of universal design, accepting allZoneline chassis of current design as well as all GE Zonelinechassis produced since 1961.

• Drain holes are provided in the rear of the wall case topermit excessive cooling condensate water, heat pumpcondensate or precipitation entering the wall case to drainfreely. A drain kit may be connected to the wall case tocontrol any water draining from the wall case. See page4 for information on RAD10 Drain Kit.

RAK901L — For installations where the wall case extends into

room, RAK901L is an insulation kit that can be used with theRAB77 or any existing non-insulated wall case to minimizethe possibility of condensation forming on the indoor side of the case during the winter.

Sub-Base

The sub-base is an optional accessory for the Zonelineand is presented with the wall case information since thedecision to use or not to use a sub-base in the installationis a factor in the location of the wall opening for the unit.National Electrical Code® requires that air conditioning unitsconnected to voltages in excess of 250 volts be “permanently

connected.” There are also some installations where unitsconnected to voltage sources under 250 volts may alsoneed to be “permanently connected.” If you are in doubtabout the requirements for a particular installation, consultArticle 440 of the NEC or the local electrical inspector. Theserequirements are designed to protect personal safety andshould be strictly followed. Although NEC is cited here as areference, all electrical wiring and installations must conformto any and all local electrical codes and regulations.

“Permanent Connection” generally means wiring to the unitmust be contained in an enclosed “chaseway,” where accessto the wiring connections is more restrictive than a normalline cord plugged into a receptacle. NEC requirements maybe met by using flexible or rigid conduit to contain the wiringbetween the unit and a junction box that contains the wiringconnections. The conduit is connected to the unit and to the

 junction box with connectors to hold the conduit in place.The junction box may be located in the floor or the wall of thestructure but only approved connectors may be used outsidethe unit or the junction box. The sub-base is UL® listed as a junction box for permanent connection of a Zoneline.

Using a sub-base in an installation requiring permanentconnection provides a convenient, consistent location forunit wiring to be connected to building wiring. The use of a sub-base is not required, but the convenience and theimproved aesthetics it offers makes the use of a sub-basea viable means of permanent connection.

RAK204U — The RAK204U Series of sub-bases provides avariety of designs that fit the site needs and are availablefor use with Zoneline PTAC/PTHP units. The RAK204U willmost likely be used for support of the wall case and unit.The RAK204U is the same physically as the other sub-basesexcept there is no receptacle installed. Receptacles andwiring can be field installed and, by using the RAK205CWchaseway and the RAK4002 junction box perform the samefunction as any of the other sub-base kits by selecting thecorrect receptacle and installing it in the interior mountingplate inside the RAK204U.

208/20-volt receptacles can also be mounted in the coverplate for easy access when direct connect wiring is notrequired. 265-volt units are to be “Permanently (or Direct)

Connected” and the external receptacle (when wiring is notenclosed in a chaseway) does not meet this requirement.A knockout for a fuseholder or a disconnect is also providedin the cover plate.

RAK204U — No receptacle, no wiring, will accept any15-, 20-, 0-amp receptacle and wiring. No chaseway isincluded. RAK205CW chaseway must be ordered separately.

The 20/208-volt sub-bases below include a short,sub-base power connection kit. Since sub-base connectedunits are not considered to be line-cord connected, aLeakage Current Detection and Interruption or Arc FaultCurrent Interrupter device is not necessary.

The junction box (RAK4002A for 2800 and 800 Seriesunits; RAK4002B for 5800 Series units) that mounts onthe chassis of 20/208-volt sub-base connected unitsmust be purchased separately.

RAK204D15P 208/20-volt 15-amp receptacle. Receptacleis NEMA6-20R with 18" of #12AWG wires attached tothe receptacle. Short power connection kit included.Chaseway included.

RAK204D20P 208/20-volt 20-amp receptacle. Receptacleis NEMA6-20R with 18" of #12AWG wires attached tothe receptacle. Short power connection kit included.Chaseway included.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 23/602

ge.com

Sub-Base (Continued)

RAK204D0P 208/20 volt 0-amp receptacle. Receptacleis NEMA6-0R with 18" of #12AWG wires attached to thereceptacle. Short power connection kit included.Chaseway included.

The junction box (RAK4002A for 2800 and 800 Seriesunits; RAK4002B for 5800 Series units) that mounts on thechassis of 20/208 volt sub-base connected units must be

purchased separately.Sub-bases for the 265 volt units:

RAK204E15 265-volt 15-amp receptacle. Receptacle isNEMA7-15R with 18" of #12AWG wires attached to thereceptacle. Chaseway included.

RAK204E20 265-volt 20-amp receptacle. Receptacle isNEMA7-20R with 18" of #12AWG wires attached to thereceptacle. Chaseway included.

RAK204E0 265-volt 0-amp receptacle. Receptacle isNEMA7-0R with 18" of #12AWG wires attached to thereceptacle. Chaseway included.

The junction box for 265-volt units is shipped with the

chassis since all 265-volt units are to be “Permanently(or Direct) Connected.”

The Power Connection Kit is not included

There are separate internal compartments to permitseparation of low voltage (Class 2) connections from linevoltage connections as required by NEC. Conduit containingbuilding wiring enters the sub-base through knockoutslocated in the rear or bottom of the sub-base and is notaccessible when the wall case is installed.

The sub-base attaches to the RAB71 wall case with two clips(field-assembled) that are screwed into pre-drilled holes in thebottom front flange of the wall case. It attaches to the RAB77

wall case with clips that fit over molded ribs without requiringthe use of screws into the wall case. See page for illustration.Since the sub-base extends under the wall case, clearancefrom the inner edge of the wall case to the finished wall mustbe 2-/8" or greater. The sub-base has 4 leveling legs andadjustable side channels to enable the area under the wallcase to be enclosed. Clearance from the bottom edge of thewall case to the finished floor must be between " and 5".

The sub-base may be used as support for the chassis andwall case in installations where the wall is of insufficientthickness to provide secure mounting of the wall case.

Wall Case Installation DataGeneral

Generally, Zoneline units are installed " to 5" above thefloor (flush to finished floor installation is possible) as nearto the center of the room as possible; underneath a windowor a glass panel is typical. Normal installation of the wallcase allows installation flexibility; from flush with thefinished interior wall to a minimum of 1/4" of the wall caseextending beyond the finished exterior of the building. Specialconsideration must be given to installations where the wallcase does not extend a minimum of 1/4" beyond the finished

exterior wall. See pages 0 and 1 for information on this typof installation. The unit may be installed high in the wall andthese installations usually require a remote thermostat andare discussed on pages 15 and 16.

Regardless of the installation, there are several things toconsider when selecting a location for installing the unit.For instance, drapery location could interfere with air

discharge, and placement of furniture may have an impacton the performance of the unit. The following informationis intended to minimize installation problems and assure you of trouble-free installation.

Refer to page 21 for required wall opening dimensions.Minimum recommended interior and exterior case projectiofor standard wall thicknesses are shown in the drawings inthis manual. The case may be installed flush with the finisheindoor wall. Special attention must be paid to room-side casprojection when the unit is installed in a ducted applicationas shown on page 9.

In walls thicker than 1-1/2" for line cord-connected units and

11-1/8" for sub-base installations, it may be necessary to instaa field-fabricated case extension or use one of the specialorder RAB71 deep wall cases. If you are unable to locate a locasource for case extensions, please contact your salesperson foa possible supplier. Such extension must be carefully flashedand sealed both to the wall case and to the wall to ensurewater integrity. This is necessary to ensure that any waterentering the wall case, either from operation of the unit or fromother sources, such as rain storms or from washing the exterioof the building, will drain from the case without the possibility ocapillary action drawing the water into either the room or thewall cavity. In an installation where the case is recessed lessthan " from the outside surface, flashing and sealing may be

all the modification necessary. In such an installation, the sideand top of the wall opening must be waterproof to preventmoisture from seeping into and damaging the walls. See page0 and 1 for suggested detail. Since the installation of a caseextension requires a considerable amount of attention, werecommend using one of the deep wall cases if the standardcase is not of sufficient depth.

Mounting an outdoor grille or louver section to the buildingface may cause a space between the outdoor coil and thelouver section. Air splitters, aligned with the ends of theoutdoor coil, must be installed between the outdoor coil inleand outlet air streams. Gaps between the outdoor coil andthe louver section may allow condenser air recirculation andaffect the operation of the unit. See page 41 for requirementfor custom louver sections.

The wall case should be level from side to side andfrom level to 1/4 bubble tilt to the outdoors. Thecondensate disposal system in the unit is designedto dissipate the condensate water generatedduring cooling operation in accordance with ARIstandards and actually uses this water for maximumunit efficiency. A level unit will also ensure properperformance of the Internal Condensate Removal (ICR)system optional on heat pump units.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 24/6024

Wall Case Installation Data (Continued)

For new construction, early planning with the architect isnecessary. Unit location, electrical connection locations, andwall openings of the proper dimensions are essential to avoidthe necessity of rework, fillers, framing, moving electricaloutlets, and other expensive modifications.

For existing construction it is important that carpentry,masonry and electrical work be performed by competent,

qualified personnel. Since installations in existing constructionmay involve removal of building material from the structure,locating the wall case must be done correctly.

Architectural Window/

Louver Installation

Many installations utilize an architectural window/louvercombination to enhance the exterior appearance of thebuilding. The exterior grille for the air conditioner is builtas an integral part of the window frame. An internal drainsystem is highly recommended for these installations (see

page 6). When this type of installation is made, there mustbe provision in the grille work for condensate water to drainto the exterior and not be routed back into the interior of the building or into the wall cavity. Failure to allow for thedrainage of condensate water can cause extensive damageto structural components. The problems associated with thelack of condensate drain consideration often show up shortlyafter the air conditioners are turned on in a new building.New buildings that have been virtually wide open duringconstruction have a significant amount of moisture in the airand in the building components that the air conditioners startremoving as they operate. The free area in the louver sectionmust also comply with the requirements shown on page 41.

The wall case should be anchored to the architecturalwindow/louver section to reduce air infiltration andexcessive vibration of the chassis and wall case during unitoperation. Field-fabricated and installed case angles arethe recommended method of securing the wall case to thewindow/louver framework.

Window, Curtain and Panel

Wall Construction

With this type of construction, provision for support of the

unit, other than by the wall itself, is often required. Suchsupport may be in the form of wood or metallic material of the proper thickness to maintain a level case. This additionalsupport should be located both near the wall and at the frontof the wall case. Sub-base (RAK204 Series) with four levelinglegs provides an excellent support for the unit in this type of installation. See page 28 for details of this type of installation.

In existing construction, common practice is to remove apane of glass, metal, wood, or other construction materialand build a frame around the wall case. Similar filler panelmaterial may be installed around the case for appearanceand weather seal.

Masonry Wall Construction

The wall case should be installed during construction andlintels should be used to support the blocks above the wallcase. The wall case will not support the concrete block.The installation instructions show how the wall case mustbe secured to the masonry and caulked. Do not remove thecardboard stiffener supplied with the wall case until readyto install the chassis. See page 29 for details of installationin masonry wall.

For existing masonry construction, wall openings must bemade by removing concrete blocks to achieve the propersize opening. Consult the builder, architect, or owner todetermine the necessity for lintels to support the blockabove the wall case.

Anchor bolts are normally required to secure the case tothe wall and shims may be required to prevent distortion of the wall case when securing the wall case to the wall. Fieldsupplied case angles can be used to position and secure thewall case to the wall and to cover oversized wall openings.

Brick, Frame, Stucco andShingle Construction

For new construction, the opening for the wall case shouldbe framed and the wall case inserted into the opening duringconstruction. Lintels should be used when the buildingmaterial is heavy and is not self-supporting (such as brick).The wall case will fit an opening of six courses of standardbrick or five courses of jumbo brick. Wall framing in thistype construction is normally on 16" centers and the wallcase will fit a framed opening spanning three 16" O.C. 2" x 4"stud spaces.

For existing construction the indoor and outdoor wall willneed to be cut out, allowing for clearances of 1/8" on all sidesof the wall case. Work should begin on the inside wall. Cut thecorrect dimensions and mark (using drill holes) the outsidewall from each corner of the inside cutout. Studding thatinterferes with the opening must be removed and a suitableframe constructed to secure the wall case and provideadequate support for case and chassis.

As shipped, the RAB71 Series or RAB77 is ready forinstallation.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 25/602

ge.com

Do not remove the stiffener from inside the wall case or theweather closure panel from the outside face of the wall caseuntil the outdoor grille and chassis are ready to be installed.

Installation of Wall Case in Wall Opening

1. Position the wall case into the wall. The room side edge of 

the RAB71 or RAB77 wall case should be at least flush withthe finished wall for line cord installations and permanentconnection installations when no sub-base is used, andshould project into the room at least 2-/8" when a sub-base is used. If the minimum exterior dimensions are notmet, refer to page 27 and 28. The outside edge of the wallcase should extend at least 1/4" beyond the outside wall.This is necessary for proper caulking, to prevent sealingthe drain holes in the rear flange of the wall case, and tofacilitate the installation of an accessory drain, if used.

The wall case should be level from side to side andfrom level to 1/4 bubble tilt to the outdoors. The

condensate disposal system in the unit is designedto dissipate the condensate water generatedduring cooling operation in accordance with ARIstandards and actually uses this water for maximumunit efficiency. A level unit will also ensure properperformance of the Internal Condensate Removal(ICR) system optional on heat pump units.

2. The wall case should be secured to the wall at both sides.Use a minimum of two screws or other fastening deviceon each side. See Figure 2 page 26. Mark the wall caseon each side 2" from the bottom and 2" from the top at apoint where basic wall structure is located. Drill wall case

and use fasteners appropriate for wall construction. Allholes for fasteners in the side of the wall case must be atleast 2" up from the bottom of the wall case. Never locatescrews or put other holes in the bottom of the wall case.The only exception is when an RAD10 drain kit is installedto connect to an internal drain system. See page 6 forRAD10 Drain Kit information.

If the wall opening is greater than the case dimensions,spacers must be used on the sides between the wall caseand the wall support structure to prevent distorting thewall case.

. Caulk or gasket the entire opening on the outside betweenthe wall case and exterior wall surface (4 sides) to providetotal water and air seal.

4. Caulk or gasket room-side opening between wall case andinterior wall surface (4 sides). Opening beneath or aroundthe wall case can allow outdoor air to leak into the roomresulting in increased operating costs and improper roomtemperature control.

Care should be taken in location of electrical supply entryin relationship to wall sleeve to assure access to receptacleor junction box once unit is installed.

• Refer to page 4 for maximum power cord length.

• Permanent connected units close to finished floor must

allow for conduit clearance.

Case Angles

In some installations such as curtain walls, window walls,or where the structural material of the wall is insufficientto support or fasten wall case to, the use of case anglesmay be used. Case angles are pieces of steel or othermaterial of similar structural strength that are formedto a 90° angle, with holes to fasten the case angle tothe wall case and to the structural component of thewall surrounding the wall case.

The following describes the procedure when field fabricatedand installed case angles are applied.

1. Position case angles around top and sides of wall caseat the desired location. Position case angles vertically oneach side of wall case to provide a level installation.

2. Mark wall case through holes in case angles. The lowesthole on the sides of the wall case must be a minimum of 2" above the bottom of the case.

. For RAB71 wall case drill 5/2" diameter holes at locationmarked on wall case in Step 2, and assemble angles towall case using #10 x 1/2" self tapping screws. For RAB77

wall case follow the same procedure except use a #10 x1/2" bolt, washer and nut to attach case angles to case.Install screws or bolts from outside wall case.

4. Do not drill any holes in bottom of wall case. Do not distowall case.

5. Do not use case angles for a lintel.

Preparation of the Wall Case for

All Types of Construction

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 26/6026

   F   R   A   M

   I   N   G   F   O   R   W   A   L   L   C   A   S   E

   B   r    i   c    k   V   e   n

   e   e   r   a   n    d   F   r   a   m   e   C   o   n   s   t   r   u   c   t    i   o   n

   F   A   S   T   E   N   I   N   G   W   A   L   L   C   A   S   E

   F    i   g   u   r   e   1

   F    i   g   u   r   e   2

   M   A   I   N   S   T   U   D

   J   A   C   K   S   T   U   D   S

   H   E   A   D   E   R  –   4   "  x   4   "   O

   R

   2  -   2   "  x   4   "   O   N   E   D   G   E

   1   6  -   1   /   4   "   M   I   N .   R   A   B   7   1

   1   6  -   1   /   2   "   M   I   N .   R   A   B   7   7

   A   D   J   U   S   T   A   B   L   E   F   R   A   M   I   N   G   T   O   S   E   C   U   R   E

   T   H   I   S   D   I   M   E   N   S   I   O   N

   4   2  -   1   /   4   "   M   I   N .

   (   R   A   B   7   1   )

   4   2  -   3   /   8   "   M   I   N .

   (   R   A   B   7   7   )

   J   A   C   K   S   T   U   D

   C   R   I   P   P   L   E

   F

   I   N   I   S   H   E   D   F   L   O   O   R

   S   U   B  -   F   L   O   O   R

   N  o   t  e  :   D  o  n  o   t  r  e  m  o  v  e   t   h  e  s   t   i   f   f  e  n  e  r

  s  u  p  p  o  r   t   f  r  o  m

   i  n  s   i   d  e   t   h  e  w  a   l   l  c  a  s  e

  u  n   t   i   l   t   h  e  c   h  a  s  s

   i  s   i  s   t  o   b  e   i  n  s   t  a   l   l  e   d .

   M   A

   I   N   S   T   U   D   S

   J   A   C   K   S   T   U   D

   H   E   A   D   E   R

   M   O   U   N   T   I   N   G

   S   C   R   E   W

    H   O   L   E

   L   I   N   T   E   L

   F  r  a  m   i  n  g   d  e   t  a   i   l   f  o  r   t   h   i  s  c  o  n  s   t  r  u  c   t   i  o  n   i  s  a  s

  s   h  o  w  n

   i  n   F   i  g  u  r  e   1 .   N  o   t  e  u  s  e  o   f   l   i  n   t  e   l  u  n   d  e  r

   f   i  r  s   t  c  o

  u  r  s  e  o   f   b  r   i  c   k  a   b  o  v  e   t   h  e   Z  o  n  e   l   i  n  e

  c  a  s  e .   D

  o

  n  o   t  u  s  e   t   h  e  c  a  s  e  a  s  a   l   i  n   t  e   l .

   M  o  u  n   t   i

  n  g  s  c  r  e  w

   h  o   l  e  s  s   h  o  w  n  a  r  e   t  o   b  e

  m  a   d  e   b

  y   t   h  e   i  n  s   t  a   l   l  e  r .

   N   O   H   O   L   E   S   P   E   R   M   I   T   T   E   D

   I   N   B   O   T   T   O   M

   O   F   C   A   S   E

   (   E   X   C   E   P   T   I   O   N  -   R   A   D   1   0

   D   R   A   I   N   K   I   T   )

   C   h  o   i  c  e

  o   f

  a   t   t  a  c   h  m  e  n   t   d  e  v   i  c  e  s

   t   h  r  o  u  g

   h   b  o   t   h  e  n   d  s  o   f  c  a  s  e  o  r   t   h  e

   t  o  p .   M

  o  u  n   t   i  n  g  s  c  r  e  w

   h  o   l  e  s  a  n   d

  a   t   t  a  c   h  m  e  n   t   d  e  v   i  c  e  s   b  y   i  n  s   t  a   l   l  e  r .

   M   A   I   N   S   T   U   D

   J   A   C   K   S   T   U   D

   2   "   M   I   N .

   W   O   O   D

   S   C   R   E   W

   M   O   L   L   Y

   O   R   T   O   G   G   L   E

   B   O   L   T

   E   X   P   A   N   S   I   O   N

   A   N   C   H   O   R

   B   O   L   T

   N   O   H   O   L   E   S   P   E   R   M   I   T   T   E   D   I   N

   B   O   T   T   O   M

   O   F   C   A   S   E

   (   E   X   C   E   P   T   I   O   N  -   R   A   D   1   0

   D   R   A   I   N   K   I   T   )

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 27/602

ge.com

   W   A   L   L   S   E   C   T   I   O   N  –   D   E   T   A   I   L   E   D   S   I   D   E   V   I   E   W

   F   r   a   m   e   a   n    d   B   r    i   c    k   V   e   n   e   e   r   I   n   s   t   a    l    l   a   t    i   o   n

   C   o   r    d   s   e   t   c   o   n   n   e   c   t   e    d

   C   A   U   L   K   *

   S   u    b  -   B   a   s   e   C   o   n   n   e   c   t   e    d

   C   A   U   L   K   *

   S   T   E   E   L

   L   I   N   T   E   L

   R   A   B   7   1

   1   3  -   3   /   4   "

   R   A   B   7   7

   1   3  -   7   /   8   "

   2   0  -   7   /   8   "

   (   R   A   B   7   1   )

   2   1   "

   (   R   A   B   7   7   )

   R   O   O   M

   C   A   B   I   N   E   T

   2   "   M   I   N .

   M   O   U   N   T   I   N   G   S   C   R   E   W   S

   B   Y   I   N   S   T   A   L   L   E   R

   R   A   B   7   1

   1   6   "

   R   A   B   7   7

   1   6  -   1   /   4   "

   W   A   L   L   C   A   S   E

   O   U   T   D   O   O   R

   G   R   I   L   L   E

   C   A   U   L   K   *

      C      A      U      L      K      *

   1   /   4   "

   M   I   N .

   R   A   G   6   0

   1   /   4   "

   R   A   G   6   1 ,

   6   2 ,

   6   3

   1  -   3   /   8   "

   R   A   G   6   4 ,

   6   5 ,

   6   6

   1  -   3   /   8   "

   P   O   W   E   R   S   U   P   P   L   Y

   C   O   N   D   U   I   T

   W   A   L   L   R   E   C   E   P   T   A

   C   L   E

   (   B   Y   O   T   H   E   R   S

   )

   F   I   N   I   S   H   E   D   F   L   O   O   R

   O   R   T   O   P   O   F

   C   A   R   P   E   T

   *   C  a  u   l   k  a  r  o  u  n   d  p  e  r   i  m  e   t  e  r  o   f  w  a   l   l  c  a  s  e  a   l   l   f  o  u  r  s   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s   t   h  e   b  u   i   l   d   i  n  g  -   I  n   t  e  r   i  o  r  a  n   d   E  x   t  e  r   i  o  r .

   C   A   U   L   K   *

   1   /   4   "

   C   A   U   L   K   *

   L   I   N   T   E   L

   R   A   B   7   1

   1   3  -   3   /   4   "

   R   A   B   7   7

   1   3  -   7   /   8   "

   2   0  -   7   /   8   "

   (   R   A   B   7   1   )

   2   1   "

   (   R   A   B   7   7   )

   R   O   O   M

   C

   A   B   I   N   E   T

   2   "   M   I   N .

   M   O   U   N   T   I   N   G   S   C   R   E   W   S

   B   Y   I   N   S   T   A   L   L   E   R    R   A

   B   7   1

   1   6   "

   R   A

   B   7   7

   1   6  -   1   /   4   "

   W   A   L   L   C   A   S   E

   O   U   T   D   O   O   R

   G   R   I   L   L   E

   S   I   D   E   C   H   A   N   N   E   L

   3   "   M   I   N .

   5   "   M   A   X .

   1

  -   5   /   1   6   "

   F   I   N   I   S   H   E   D   F   L   O   O   R

   O   R   T   O   P   O   F

   C   A   R   P   E   T

   S

   U   B  -   B   A   S   E

   (   R   A   K   2   0   4   )

   C   A   U   L   K   *

   P   O   W   E   R   S   U   P   P   L   Y   C   O   N   D   U   I   T

   (   A   L   T   E   R   N   A   T   E   E   N   T   R   Y   )

   3  -   1   1   /   1   6   "

   *   C  a  u   l   k  a  r  o  u  n   d

  p  e  r   i  m  e   t  e  r  o   f  w  a   l   l

  c  a  s  e  a   l   l   f  o  u  r  s   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s   t   h  e

   b  u   i   l   d   i  n  g  -   I  n   t  e  r   i  o  r

  a  n   d   E  x   t  e  r   i  o  r .

   2  -   3   /   8   "

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 28/60

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 29/602

ge.com

   W   A   L   L   C   A   S   E   I   N   S   T   A   L   L   A   T   I   O   N  –   C   O   R   D   S   E   T   C   O   N   N   E

   C   T   E   D

   E   x   a   m   p    l   e   :    b    l   o   c    k   a   n

    d   v   e   n   e   e   r  –    d    i   m   e   n   s    i   o   n   a    l    d   a   t   a   a   n    d   c   o   m   m   e   n   t   s

   A   r   e   a    l   s   o   a   p   p    l    i   c   a    b    l   e   t   o   o   t    h   e   r   t   y   p   e   s   o    f   c   o   n   s   t   r   u   c   t    i   o

   n

   M  a  n  u   f  a  c   t  u  r  e  r   R  e  q  u   i  r  e   d

   M   i  n   i  m  u  m

   I  n  s   t  a   l   l  a   t   i  o  n   C   l  e  a  r  a  n  c  e

   1   /

   4   "   (   S  e  e  n  o   t  e   1   )

   A   l   l  o  w   F  o  r   E   l  e  c   t  r   i  c

  a   l   W   i  r   i  n  g   0   "   M   i  n .   (   S  e  e  p  a  g  e   2   7   )

   0   "   M   i  n   i  m  u  m

   0   "   M   i  n   i  m

  u  m

   2   "   R  e  c  o  m  m  e  n   d  e   d

   S  e  e  p  a  g  e  s   3   8

  -   3   9   f  o  r   d  u  c   t  e   d  a  p  p   l   i  c  a   t   i  o  n .

   3   "   M   i  n   i  m  u  m

   F   I   N   I   S   H   E   D

   E   X   T   E   R   I   O   R   W   A   L   L

   D   i  m  e  n  s   i  o  n

   A    B C    D    E

   N   O   T   E  :

   1 .

   F   O   R   O   U   T   S   I   D   E   F   L   U   S   H   M   O   U   N   T   I   N   G   S   E   E   P   A   G   E   3   5

   F   O   R   D   R   A   I   N   I   N   S   T   A   L   L   A   T   I   O   N .

   C   A   U   L   K   *

   C   A   U   L   K   *

   C   A   U   L   K   *

   C   A   U   L   K   *

   C   A   U   L   K   *

   C   A   U   L   K   *

   C   A   S   E

   R   A   B   7   1

   4   2   "

   R   A   B   7   7

   4   2  -   1   /   8   "

   F   I   N   I   S   H   E   D

   E   X   T   E   R   I   O   R

   W   A   L   L

   R   O   O   M

   C   A   B   I   N   E   T

   R   A

   B   7   1

   1   3  -   3   /   4   "

   R   A

   B   7   7

   1   3  -   7   /   8   "

   A   D   J   A   C   E   N   T   W   A   L   L

   A   D   J   A   C   E   N   T   W   A   L   L

   D

   A    C   D

   2   7  -   1   /   4   "

   T   O   P   V   I   E   W

   2  -   1   /   2   "

   *   C  a  u   l   k

  a  r  o  u  n   d  p  e  r   i  m  e   t  e  r  o   f  w  a   l   l  c  a  s  e  a   l   l   f  o  u  r  s   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s   t   h  e   b  u   i   l   d   i  n  g  -   I  n   t  e  r   i  o  r  a  n   d   E  x   t  e  r   i  o  r .

   R   O   O   M

   C   A   B   I   N   E   T

   L   I   N   T   E   L

   F   R   O   N   T   V   I   E   W

   E   L   E   C   T   R   I   C   A   L

   R   E   C   E   P   T   A   C   L   E   (   B   Y   O   T   H   E   R   S   ) .

   F   L   U   S   H   M   O   U

   N   T   E   D .

   W   A   L   L   O   P   E   N   I   N   G

   1   6  -   1   /   4   "  x   4   2  -   1   /   4   "   M   I   N .

   F   O   R   R   A   B   7   1

   1   6  -   1   /   2   "  x   4   2  -   3   /   8   "   M   I   N .

   F   O   R   R   A   B   7   7

   S   e   e   p   a   g   e   4   2    f   o   r    l    i   n   e   c   o   r    d    l   e   n   g   t    h .

   I   N   S

   I   D   E

   M   A   X .   W

   A   L   L   T   H

   I   C   K   N   E   S   S

   1   3  -   1   /   8

   "

   E

   B

   A   C   A   U   L   K   *

   F   I   N   I   S   H   F   L   O   O   R

   *   C  a  u   l   k  a  r  o  u  n   d

  p  e  r   i  m  e   t  e  r  o   f  w  a   l   l  c  a  s  e

  a   l   l   f  o  u  r  s   i   d  e  s  w   h  e  r  e   i   t

   j  o   i  n  s   t   h  e   b  u   i   l   d   i  n  g  -

   I  n   t  e  r   i  o  r  a  n   d   E  x   t  e  r   i  o  r .

   R   O   O   M

   C   A   B   I   N   E   T

   7  -   1   /   8   "

   R   A   B   7   1

   1   3  -   3   /   4   "

   R   A   B   7   7

   1   3  -   7   /   8   "

   1   6   "   R   A   B   7   1

   1   6  -   1   /   8   "   R   A   B   7   7

   S   I   D   E   V   I   E   W    O

   F

   A   L   T   E   R   N   A   T   E

   H   I   G   H   M   O   U   N   T

   W   i   t   h  c  o  n   d  u   i   t

  p  o  w  e  r  s  u  p  p   l  y .

   C   O   N   D   U   I   T

   F   I   E   L   D

   S   U   P   P   L   I   E   D

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 30/60

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 31/60

ge.com

   C   A   U   L   K   *

   A

   D   I   M   E   N   S   I   O

   N   S  :

   A .

   D   I   S   T   A   N

   C   E   F   R   O   M

   G   R   I   L   L   E   O   R   C   A   S   E   T   O   O   U   T   S   I   D   E   S   U   R

   F   A   C   E   O   F   W   A   L   L   P   L   U   S   2   "   T   O   4   "

   (   T   O   I   N   S   E   R

   T   U   N   D   E   R   C   A   S   E   ) .

   B .

   1   "   D   R   I   P

   L   I   P   (   M   I   N   I   M   U   M   )

   C .

   4   2   "   P   L   U

   S  -   S   U   F   F   I   C   I   E   N   T   T   O   F   I   T   S   N   U   G   G   L   Y   U   N   D   E   R   A   N   D   U   P   A   R   O   U   N   D   T   H   E   C   A   S   E .

   D .

   2   "   M   I   N   I   M   U   M

   (   C   A   U   T   I   O   N

  :   W   H   E   N   C   A   U   L   K   I   N   G   D   O   N   O   T   B   L   O   C   K   D   R   A   I   N   H   O   L   E   S   I   N   C   A   S   E   O   R   G   R   I   L   L   E .   )

   I   F   G   R   I   L   L   E

   I   S   T   O   B   E   M   O   U   N   T   E   D   T   O   W   A   L   L   S   U   R   F   A   C   E   A   S   P   L   I   T   T   E   R   S   M   U   S   T   B   E   U   S   E   D ,

   S   E   E   P   A   G   E   3   0 .

   B

   D

   C

   A

   B

   *   C  a

  u   l   k  a  r  o  u  n   d  p  e  r   i  m  e   t  e  r  o   f  w  a   l   l  c  a  s  e  a   l   l   f  o  u  r  s   i   d  e

  s

  w   h  e  r  e   i   t   j  o   i  n  s   t   h  e   b  u   i   l   d   i  n  g  -   I  n   t  e  r   i  o  r  a  n   d   E  x   t  e  r   i  o  r .   1   "   W

   I   D   E   4   5   °   D   R   I   P   L   I   P

   F   L   A   S   H   I   N   G

   O   U   T   D   O   O   R

   G   R   I   L   L   E

   C   A   S   E

   F   o   r   a   n    i   n   s   t   a    l    l   a   t    i   o   n   t    h   a   t   w    i    l    l

   p   r   o   v    i    d   e    b   e   t   t   e   r   p   r   o   t   e   c   t    i   o   n

   a   g   a    i   n   s   t   w   a   t   e   r    i   n    f    i    l   t   r   a   t    i   o   n ,

   G   E   r   e   c   o   m   m   e   n    d   s   t    h   e   u   s   e

   o    f   o   n   e   o    f   t    h   e    d   e   e   p   e   r   R   A   B   7   1

   w   a    l    l   c   a   s   e   s   o    f    f   e   r   e    d   a   s

   s   p   e   c    i   a    l   o   r    d   e   r    i   t   e   m   s .

   S   e   e   p   a   g   e   2    .

   A   L   T   E   R   N   A   T   E  –   C   A   S   E   R   E   C   E   S   S   I   O   N   L   E   S   S   T   H   A   N      "   W   I   T   H   S   I   D

   E   S   A   N   D   T   O   P   O   F   W   A   L   L   O   P   E   N   I   N

   G   W   A   T   E   R   P   R   O   O   F ,   F   L   A   S   H   I   N   G   O   N   B   O   T   T   O   M   O   N   L   Y

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 32/602

   R   A   B   7   1    /   7   7   W   A   L   L   C   A   S   E   I   N   S   T

   A   L   L   A   T   I   O   N  -   R   A   K   2   0   4   S   E   R   I   E   S   S   U   B  -   B   A   S   E   C   O   N   N   E   C   T   E   D

   E   x   a   m   p    l   e   :    f   r   a   m   e   &    b   r    i   c    k   v   e   n   e   e   r  -    d    i   m   e   n   s    i   o   n   a    l    d   a   t   a   a   n    d   c   o   m   m   e   n   t   s

   A   r   e   a    l   s   o   a   p

   p    l    i   c   a    b    l   e   t   o   o   t    h   e   r   t   y   p   e   s   o    f   c   o   n   s   t   r   u   c   t    i   o   n

   T   O   P   V   I   E   W

   M  a  n  u   f  a  c   t  u  r  e  r   R  e  q  u   i  r  e   d

   M   i  n   i  m  u  m

   I  n  s   t  a   l   l  a   t   i  o  n   C   l  e  a  r  a  n  c  e

   1   /   4   "   (   S

  e  e  n  o   t  e   1   )

   3   "   M   i  n .

   (   5   "   M   A   X .   )

   2  -   3   /   8   "

   M   i  n   i  m  u  m

   0   "   M   i  n   i  m  u  m   2

   "   R  e  c  o  m  m  e  n   d  e   d

   S  e  e  p  a  g  e  s   3   8  -   3   9   f  o  r   d  u  c   t  e   d  a  p  p   l   i  c  a   t   i  o  n .

   D   i  m  e  n  s   i  o  n

   A    B C    D   N   O   T   E  :

   1 .   F   O   R   O   U   T   S   I   D   E   F   L   U   S   H   M   O   U   N   T   I   N   G   S   E   E

   P   A   G   E   3   1   F   O   R

    F   L   A   S   H   I   N   G   I   N   S   T   A   L   L   A   T   I   O   N .

   2  -   3   /   8   "

   M   I   N .

   F   I   N   I   S   H   E   D

   I   N   T   E   R   I   O   R

   W   A   L   L

   L   E   V   E   L   I   N   G   S   C   R   E   W

   L   E

   V   E   L   I   N   G   S   C   R   E   W

   R   A   B   7   1   1   3  -   3   /   4   "

   R   A   B   7   7   1   3  -   7   /   8   "

   5 .   1

   5   "

   7 .   7   0   "

   1   8 .   8

   6   "

   1 .   5   "

   5 .   1

   5   "

   7 .   7   0   "

   1   0 .   3

   0   "

   8 .   8

   0   "

   B   A   C   K   V   I   E   W

   F   R   O   N   T   V   I   E   W

   4   2   "

   D

   D   S   E   E   N   O   T   E

   L   E   F   T   S   I   D   E

   I   N   T   E   R   I   O   R

   A   D   J   A   C   E   N   T

   W   A   L   L

   1   2  -   3   /   4

   "

   1   2  -   7   /   8   "

   1   3   "

   L   E   V   E   L   I   N   G   S   C   R   E   W

   K   N   O   C   K   O   U   T   S   I   Z

   E

   L   A   R   G   E

   1  -   1   /   8   "   D

   I   A .

   S   M   A   L   L

   7   /   8   "   D

   I   A .

   K   N   O   C   K   O   U   T   S

   (   E   N   C   L   O   S   U   R   E   )

   4   R   E   A   R  ;   4   B   O   T   T   O   M

   *   S   H   O   W   N   W   I   T   H   A   C   C   E   S   S   C   O   V   E   R   S   R   E   M   O   V   E   D .

   N   O   T   E   :   C   A   U   T   I   O   N  -   R   E   M   O   V   E   K   N   O   C   K   O   U   T   S   F   R   O   M   I   N   S   I   D   E   O   U   T .

   S   I   D   E   V   I   E   W

   W   I   T   H   W   A   L   L

   C   A   S   E   S   H   O   W   N

   I   N   P   L   A   C   E

   F   I   N   I   S   H   E   D   F   L   O   O

   R

   3   "   M   I   N

 .

   A   D   J   U   S

   T   A   B   L   E

   T   O   5   "

   1  -   5   /   1   6   "

   2  -   3   /   8   "

   I   N   T   E   R   I   O   R

   W   A   L   L

   R   A   B   7   1

   1   6   "

   R   A   B   7   7

   1   6  -   1   /   4   "

   7   /   8   "

   1  -   1   /   2   "

   F   I   N   I   S   H   E   D   F   L

   O   O   R

   R   A   B   7   1

   1   6   "

   R   A   B   7   7

   1   6  -   1   /   4   "

   S   I   D   E   V   I   E   W

   M   A   X .   W

   A   L   L   T   H   I   C   K   N   E   S   S

   1   1  -   1   /   8   "

   M   O   U   N   T   I   N   G   S   C   R   E   W   S

   A   N   D   H   O   L   E   S   B   Y

   I   N   S   T   A   L   L   E   R

   L   E   V   E   L   I   N   G   S   C   R   E   W   S

   (   2   )   S   U   B  -   B   A   S   E   B   O   D   Y

   (   2   )   S   I   D   E   E   X   T   E   N   S   I   O   N   S

   C   O   N   D   U   I   T   E   N   T   R   Y

   (   A   L   T   E   R   N   A   T   E   S   )

   C   A   U   L   K   *

     R     O     O      M

     C     A     B  I     N    E    T

   C

   A

   B

   C   A   U   L   K   *

   3  -   1   1   /   1   6   "

   2  -   3   /   8   "   M   I   N .

   C   A   S   E

   E   D   G   E   T   O

   F   I   N   I   S   H   E   D

 

   W   A   L   L

   1   3  -   3   /   4   "

   C   A   U   L   K   *

   *   C  a  u   l   k  a  r  o  u  n   d

  p  e  r   i  m  e   t  e  r  o   f

  w  a   l   l  c  a  s  e  a   l   l

   f  o  u  r  s   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s

   t   h  e   b  u   i   l   d   i  n  g

  -   I  n   t  e  r   i  o  r  a  n   d

   E  x   t  e  r   i  o  r .

   R   E   C   O   M   M   E   N   D   2   "   T   O

   I   N   T   E   R   I   O   R   A   D   J   A   C   E   N   T

   W   A   L   L   B   O   T   H   S   I   D   E   S .

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 33/60

ge.com

   R   A   K   2   0   4   S   E   R   I   E   S   S   U   B  -   B   A   S   E   I   N   S   T   A   L   L   A   T   I   O   N   A   N   D   E   L   E   C   T   R   I   C   A   L   D   A   T   A

   R   A   B   7   1    /   7   7   W   a    l    l   C   a   s   e

   R   A   K   4   0   0   2   B

   C   H   A   S   E   W   A   Y   O   P   T   I   O   N

   (   S   h  o  w  n   W   i   t   h  o  u   t   C

   h  a  s  s   i  s  a  n   d   W  a   l   l   C  a  s  e   f  o  r   I  n  s   t  a   l   l  a   t   i  o  n   L  o  c  a   t   i  o  n

   O  n   l  y .   )

   N   O   T   E  :   T   Y   P   E   “   E   ”

   M   O   U   N   T   I   N   G   C   L   I   P   M   U

   S   T

   B   E   U   S   E   D   W   I   T   H   M   O   L   D   E   D

   C   A   S   E .

   M   O   L   D   E   D

   C   A   S   E

   S   U   B  -   B   A   S   E

   M   O   U   N   T   I   N   G   C   L   I   P

   T   Y   P   E   “   E   ”

   T   Y   P   E

   “   D   ”

   U   S   E   W   I   T   H

   R   A   B   7   1

   T   Y   P   E

   “   E   ”

   U   S   E   W   I   T   H

   R   A   B   7   7

    T   Y   P   E   “   A   ”

   T   Y   P   E   “   B   ”

   T   Y   P   E   “   C   ”

    6   R   E   Q   ’   D .

   2

   R   E   Q   ’   D .

   8   R   E   Q   ’   D .

   G   R   E   E   N

   G   R   O   U   N   D

   S   C   R   E   W

   (   T   Y   P   E   “   C   ”   )

   M   E   T   A   L   C   A   S   E

   S   C   R   E   W    C

   L   I   P

   T   Y   P   E   “   D   ”

   T   Y   P   E   “   A   ”

   S   C   R   E   W

   T   O   S   E   C   U   R   E

   S   I   D   E   C   H   A   N   N   E   L   S

   6   "

 

   5   /   3   2   "   D   I   A .

   H   O   L   E   (   S   E   E   N   O   T   E   )

    F   O   R   S   E   C

   U   R   I   N   G   T   Y   P   E   “   D   ”

   C   L   I   P   S   T   O   S

   L   E   E   V   E   U   S   I   N   G

   T   Y   P   E   “   A   ”   S

   C   R   E   W   S

   6   "

   T   Y   P   E   “   A   ”

   S   C   R   E   W

   T   Y   P   E

   “   C   ”

   S   C   R   E   W

   A   C   C   E   S   S   P   L   A   T   E   S

   T   Y   P   E   “   C   ”

   S   C   R   E   W

   T   Y   P   E   “

   B   ”   S   C   R   E   W

   S   I   D   E   C   H   A   N   N   E   L   S   A   R   E   A   D   J   U   S   T   A   B   L   E

   F   R   O   M

   1   3  -   3   /   4   "   T   O   2  -   3   /   8   "   I   N   L   E   N   G   T   H

   B   Y   B   R   E   A   K   I   N   G   O   F   F   S   E   C   T   I   O   N   S   O   F   S   I   D   E

   C   H   A   N   N   E   L   S .

   N   O   T   E  :   I   F   M   E   T   A   L   C   A   S   E   D   O   E   S   N   O   T   H   A   V   E

   S   C   R   E   W    H

   O   L   E   S ,

   5   /   3   2   "   D   I   A .

   H   O   L   E   S   M   U   S   T

 

   B   E   D   R   I   L   L   E   D   6   "   F   R   O   M

   E   A   C   H   S   I   D   E

   I   N   F   R   O   N   T   F   L   A   N   G   E .

   (   S   E   E   I   N   S   E   R   T   ) .

   E    l   e   c   t   r    i   c   a    l   w    i   r    i   n   g   m   a   y   e   n   t   e   r   t    h   e   s

   u    b  -    b   a   s   e   t    h   r   o   u   g    h   a   n   y   o    f   t    h   e    k   n   o   c    k   o   u   t    h   o    l   e   s   p   r   o   v    i    d   e    d    i   n   t    h   e   s   u    b  -    b   a   s   e .

   K   n   o   c    k   o   u   t    h   o    l   e   s    i   n   t    h   e   s   u    b  -    b   a   s   e   a   c   c   e   s   s   p    l   a   t   e   m   a   y   a   c   c   o   m   m   o    d   a   t   e   a   r   e   c

   e   p   t   a   c    l   e ,   w

    h    i   c    h   a    l    l   o   w   s   t    h   e   u   s   e   o    f   a   p   o   w   e   r   c   o   r    d    (    i    f   p   e   r   m    i   t   t   e    d    b   y   c   o    d   e    f   o   r   t    h   e

   p   a   r   t    i   c   u    l   a   r    i   n   s   t   a    l    l   a   t    i   o   n    ) .

   A    k   n   o   c    k   o   u   t    f   o   r   a   c    i   r   c   u    i   t    b   r   e   a    k   e   r ,

    f   u   s   e    h   o    l    d   e   r   o   r   a    d    i   s   c   o   n   n   e   c   t    i   s   a    l   s   o   p   r   o   v    i    d   e    d .   S   e   e   p   a   g   e   s   2   2   a   n    d   2       f   o   r    d   e   s   c   r    i   p   t    i   o   n   o    f   e    l   e   c   t   r    i   c   a    l   c   o   n   t   e   n   t   s   o    f   t    h   e   s   e

   s   u    b  -    b   a   s   e   s .

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 34/604

Condensate Disposal Systems

Cooling CondensateAir conditioners produce condensate water as a result of lowering the humidity of the area being conditioned. Whenthe indoor coil temperature is below the dew point, moisturein the air condenses into water droplets on the coil. This waterdrains to a pan located under the indoor coil and is routedthrough the barrier, the partition separating the indoor and

outdoor sides of the unit, to the base pan on the outdoor side.It is then picked up and dispersed against the outdoor coil,which is hot when the unit is in the air conditioning mode.The water is evaporated into the atmosphere by contactwith the hot outdoor coil. This evaporation process also helpslower the temperature of the outdoor coil and improves theoperating efficiency of the unit.

Slinger Ring SystemsPackaged Terminal units employ various means of dispersingthe condensate water against the outdoor coil. One of the mostpopular, and most effective, means is by the use of a “slingerring.” A “slinger ring” is a ring around the circumference of 

the outdoor fan. The design of the unit positions the slingerring very close to the bottom of the base pan so water inthe base pan is lifted by the rotating ring. Water picked upby the slinger ring will be dispersed into the air stream anddeposited on the hot outdoor coil where it evaporates.

All Zoneline Series Packaged Terminal Air Conditionersand Packaged Terminal Heat Pumps utilize a slinger ringfor cooling condensate disposal.

Certification Test RequirementsARI (Air Conditioning & Refrigerating Institute) requires that allcertified Packaged Terminal Air Conditioners and PackagedTerminal Heat Pumps pass a cooling condensate disposal

test. One stipulation of the ARI test is that “the test start withcondensate collection pan brimful.” In order to pass the ARICondensate Disposal Test the unit must operate continuouslyfor four hours without condensed water blowing, dripping,or running off the unit casing during the test or after theunit has been turned off. Under extremely high outdoorhumidity conditions or extreme operating conditions, suchas exceptionally high air infiltration (a door or window leftopen while the unit is running, for instance) it is possible forany air conditioner to be unable to dissipate all the coolingcondensate generated.

All Zoneline® Series Packaged Terminal Air Conditionersand Packaged Terminal Heat Pumps meet the condensate

disposal requirements of ARI standards 10-9 and 80-9.

Heat Pump CondensateDuring the operation of a unit in the heat pump, or “reversecycle,” mode the outdoor coil becomes the cold coil and theindoor coil becomes the hot coil due to reversing the flow of the refrigerant. When the temperature of the outdoor coil isbelow the dew point, condensation will form on the outdoorcoil just as it does on the indoor coil during cooling operation.Since the dew point is humidity- as well as temperature-related, there may be more condensate on days when therelative humidity is high.

Heat Pump Condensate DisposalSince the outdoor coil is cold during heat pump operation, thecondensate water cannot be deposited on the outdoor coilas the water would cause frost to form on the coil. This frostwould block the airflow through the coil and greatly reduce theoutdoor air. Rather than allow this problem to occur, heat pumpunits must dispose of the condensate in another manner.

Temperature-Activated Drain ValveThe most widely used method of disposing of heat pump condensateis with a “Temperature-ActivatedDrain Valve.” This is a device mountedin the base pan of a heat pumpunit with a bellows that expands ontemperature rise and contracts withtemperature drop. A shaft with arubber plug on the end is connectedto the bellows. When the outdoor

temperature remains above a certain temperature, the

bellows is expanded and the plug fits tightly into a holein the bottom, or base pan, of the unit. When the plug isblocking the hole, as it should be during cooling operation,the condensate water is contained in the base pan. Attemperatures when heating is required, the bellowscontracts, the rubber plug is retracted from the hole andthe heat pump condensate water is allowed to drain intothe wall case. The valve is fully open at 49°F.

Drain KitsAlthough the Zoneline units are designed to dissipate all of the condensate generated during normal cooling operation,there may be times when abnormal operating conditionscause more condensate than the unit can dissipate. Heatpumps also generate condensate that the unit may notbe designed to dissipate. For these reasons, if condensatedripping from the wall case is objectionable, an internal orexternal drain system should be installed. See pages 5 and6 for information covering the drain systems and the RAD10kit available to connect to the wall case.

Internal Condensate Removal (ICR) SystemGE has developed an Internal Condensate Removal (ICR)System for Packaged Terminal Heat Pumps. This system hasbeen offered as an option on Zoneline Packaged TerminalHeat Pumps since 1982, and thousands of them are in use.During heat pump operation the ICR system utilizes a small

pump to lift the water from the base pan and pump it intoa collector tray positioned above the indoor coil. The waterdrains from the collector tray and drips onto the warm indoorcoil where it is evaporated into the room atmosphere. If anexcess amount of water is pumped to the indoor side, it isrouted back to the outdoor portion of the base pan.

The ICR system has proven to be an effective means of minimizing the amount of heat pump condensate drippingfrom the unit. However, if the restrictions of a particularinstallation will allow absolutely no drippage of condensatewater from the wall case, the installation of an internal orexternal drain system is recommended.

Units with ICR may not be installed in seacoast or corrosiveenvironment applications.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 35/60

ge.com

   W   A   L   L

   C   A   S   E   W   I   T   H   R   A   D   1   0   D   R   A   I   N   K   I   T

   E   x   t   e   r   n   a    l

   D   r   a    i   n .   S   e   e   p   a   g   e      6    f   o   r    i   n   t   e   r   n   a    l    d   r   a    i   n

 .

   S   E   E   P   A   G   E   3   6   N   O   T   E   #   6

   S   C   R   E   W   S

   R   E   A   R

   G   R   I   L   L   E

   “   A   ”

   M   E   T   A   L

   “   B   ”

   P   L   A   S   T   I   C

   S   Q   U   A   R   E   D   R   A   I   N   H   O   L   E   S

   N   E   O   P   R   E

   N   E   S   P   O   N   G   E   G   A   S   K   E   T

   1   /   2   "   O .   D .

   9   0   °   E   L   B   O   W

    D   R   A   I   N   T   U   B   E

   S   T   E   E   L   M   O   U   N   T   I   N   G

   P   L   A   T   E

   U   S   E   T   Y   P   E   “   A   ”

   S   C   R   E   W    F

   O   R   M   E   T   A   L   C   A   S   E   (   R   A   B   7   1   )

   A   N   D   T   Y   P   E   “   B   ”   S   C   R   E   W    F

   O   R   M   O   L   D   E   D   C   A   S   E   (   R   A   B   7   7   )

   A   l   t  e  r  n  a   t  e

   6   "   l  o  n  g ,   1   /

   2   "

   O .   D .  s   t  r  a   i  g   h   t

  c  o  p  p  e  r   t  u   b

  e .   N

   O   T   E  :   S   H   A   D   E   D   P   A   R   T   S   A   N   D

   S   C   R   E   W   S   A   R   E   I   N   C   L   U   D   E   D

   W   I   T   H   R   A   D   1   0   D   R   A   I   N

   K   I   T .   U   S   E   E   I   T   H   E   R   T   H   E

   9   0   °   E   L   B   O   W

    T   U   B   E   O   R

   T   H   E   S   T   R   A   I   G   H   T   T   U   B   E

   D   E   P   E   N   D   I   N   G   U   P   O   N

   T   H   E   R   E   Q   U   I   R   E   M   E   N   T   S

   O   F   T   H   E   P   A   R   T   I   C   U   L   A   R

   I   N   S   T   A   L   L   A   T   I   O   N .

   W   A   L   L   C   A   S   E

   R   O   O   M

   C   A   B   I   N   E   T

   P   R   O   J   E

   C   T   I   O   N

   B   E   Y   O   N   D   W   A   L   L

   C   A

   S   E

   9   0   °

   E   L   B   O   W

   D   R   A

   I   N   T   U   B   E

   M   I   N .

   2   S   U   P   P   O   R   T

   S

   F   I   E   L   D   S   U   P   P   L   I   E   D

   F   L   O   O   R

   C   A   S   E   A   N   G   L   E   S   (   F

   I   E   L   D   S   U   P   P   L   I   E   D   )

   T   Y   P

   I   C   A   L   I   N   S   T   A   L   L   A   T   I   O   N

   C  a  u   l   k

  a  r  o  u  n   d

  p  e  r   i  m

  e   t  e  r  o   f

  w  a   l   l  c

  a  s  e  a   l   l

   f  o  u  r  s

   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s

   t   h  e   b  u   i   l   d   i  n  g .

   3   "

   4   "

   W   A   T   E   R   D   R   A   I   N   A   G   E  -   P   r   e   c    i   p    i   t   a   t    i   o   n   e   n   t   e   r    i   n   g   t    h   e   u   n    i   t   t    h   r   o   u   g    h   t    h   e   o   u   t    d   o   o   r    l   o   u   v   e   r   m   a   y

   n   o   t    b   e   r   e   m   o   v   e    d   e   n   t    i   r   e    l   y    b   y   t    h   e

   c   o   n    d   e   n   s   a   t   e   r   e   m   o   v   a    l   s   y   s   t   e   m .   T

    h   e    b   a   s   e

   p   a   n    f    l   a   n   g   e    i   s    d   e   s    i   g   n   e    d   t   o   a    l    l   o   w   e   x   c   e   s   s   w   a   t   e

   r ,   e    i   t    h   e   r   c   o   n    d   e   n   s   a   t   e   w   a   t   e   r   o   r

   p   r   e   c    i   p    i   t   a   t    i   o   n ,   t   o    f    l   o   w    i   n   t   o   t    h   e   w   a    l    l   c   a   s   e   a   n    d    d   r   a    i   n   t    h   r   o   u   g    h   t   w   o    d   r   a    i   n    h   o    l   e   s    i   n   t    h   e   r   e   a   r   o    f   t    h   e   w   a    l    l   c   a   s   e .   I

    f   t    h   e   r   e    i   s   m   o   r   e

   w   a   t   e   r    i   n   t    h   e   w   a    l    l   c   a   s   e   t    h   a   n   c   a   n    b   e    d   r   a

    i   n   e    d   t    h   r   o   u   g    h   t    h   e   s   e    h   o    l   e   s    i   t   w    i    l    l    d   r   a    i   n   t    h   r   o   u   g    h

   t    h   e   t    h   r   e   e   o   v   e   r    f    l   o   w    d   r   a    i   n    h   o    l   e   s .

   T    h   e   s   e    d   r   a    i   n    h   o    l   e   s   m   u   s   t   n   o   t    b   e    b    l   o   c    k   e    d

   w    h   e   n   m   o   u   n   t    i   n   g   o   r   c   a   u    l    k    i   n   g   t    h   e   w   a    l    l   c   a   s   e .

   F   o   r   t    h   o   s   e    i   n   s   t   a    l    l   a   t    i   o   n   s   w    h   e   r   e   w   a   t   e   r    d   r   a    i   n    i   n   g    f   r   o   m   t    h   e    d   r   a    i   n    h   o    l   e   s    i   s   o    b    j   e   c   t    i   o   n   a    b    l   e   o   r

   w    h   e   r   e   p   o   s    i   t    i   v   e    d   r   a    i   n   a   g   e    i   s    d   e   s    i   r   e    d ,

   t    h   e   R   A   D   1   0    d   r   a    i   n    k    i   t    i   s   a   v   a    i    l   a    b    l   e   w    i   t    h   e    i   t    h   e   r   a   9   0   °   e    l    b   o   w   o   r   a   6   "   s   t   r   a    i   g    h   t   t   u    b   e   t   o    b   e   u   s

   e    d   e    i   t    h   e   r   t   o   c   o   n   n   e   c   t   t   o   a    f    i   e    l    d   s   u   p  -

   p    l    i   e    d    d   r   a    i   n    l    i   n   e   o   r   t   o   a    l    l   o   w   t    h   e   w   a   t   e   r   t   o    d   r    i   p    f   r   e   e   r   a   t    h   e   r   t    h   a   n    d   r   a    i   n    d   o   w   n   t    h   e   s   u   r    f   a   c   e   o    f   t    h   e    b   u    i    l    d    i   n   g .

   N   O   T   E   :   D   r   a    i   n    k    i   t   u   s    i   n   g   e    i   t    h   e   r   t    h   e   9   0   °   e    l    b   o   w   t   u    b   e   o   r   t    h   e   s   t   r   a    i   g    h   t   t   u    b   e   m   a   y    b   e    i   n   s   t   a    l    l   e    d   w    i   t    h   o   u   t   m   o    d    i    f    i   c   a   t    i   o   n   w    h   e   n   u   s    i   n   g

   R   A   G   6   0   e   x   t   e   r    i   o   r   g   r    i    l    l   e .   D   r   a    i   n    k    i   t   u   s    i   n   g   t    h   e   9   0   °   e    l    b   o   w   t   u    b   e   m   a   y    b   e    i   n   s   t   a    l    l   e    d   w    i   t    h   o   u   t   m

   o    d    i    f    i   c   a   t    i   o   n   w    h   e   n   u   s    i   n   g   R   A   G   6   1

   t    h   r   o   u   g    h   R   A   G   6   6   e   x   t   e   r    i   o   r   g   r    i    l    l   e   s .   M   o    d    i    f    i   c

   a   t    i   o   n   m   u   s   t    b   e   m   a    d   e   t   o   t    h   e   R   A   G   6   1   t    h   r   o   u   g    h   R   A

   G   6   6   e   x   t   e   r    i   o   r   g   r    i    l    l   e   s   w    h   e   n   u   s    i   n   g   t    h   e

   s   t   r   a    i   g    h   t   t   u    b   e .   M   o    d    i    f    i   c   a   t    i   o   n   m   u   s   t    b   e   m   a    d   e   t   o   t    h   e   R   A   G   6   7   g   r    i    l    l   e    i    f   u   s    i   n   g   e    i   t    h   e   r   t    h   e   9   0   °   e

    l    b   o   w   t   u    b   e   o   r   t    h   e   s   t   r   a    i   g    h   t   t   u    b   e    (   s   e   e

    i   n   s   t   a    l    l   a   t    i   o   n    i   n   s   t   r   u   c   t    i   o   n   s   w    i   t    h   t    h   e   R   A   G   6

   7   g   r    i    l    l   e    ) .

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 36/606

   W   A   L   L

   C   A   S   E   W   I   T   H   R   A   D   1   0   D   R   A   I   N   K   I   T

   I   n   t   e   r   n   a    l   D   r   a    i   n .   S   e   e   p   a   g   e      5    f   o   r   e   x   t   e   r   n   a    l    d   r   a    i   n

 .

   S   C   R   E   W   S

   “   A   ”

   M   E   T   A   L

   “   B   ”

   P   L   A   S   T   I   C

   S   Q   U   A   R   E   D   R   A   I   N   H   O   L   E   S

   N   E   O   P   R   E   N   E   S   P   O   N   G   E   G   A   S   K   E   T

   S   T   E   E   L   M   O   U   N   T   I   N   G   P   L   A   T   E

   U   S   E   T   Y   P   E   “   A   ”   S   C   R   E   W    F

   O   R   M   E   T   A   L   C   A   S

   E   (   R   A   B   7   1   )

   A   N   D   T   Y   P   E   “   B   ”   S   C   R   E   W    F

   O   R   M   O   L   D   E   D   C

   A   S   E   (   R   A   B   7   7   )

   N

   O   T   E  :   S   H   A   D   E   D   P   A   R   T   S   A   N   D   S   C   R   E   W   S

   I   N   C   L   U   D   E   D   W   I   T   H   R   A   D   1   0   D   R   A   I   N

   K   I   T .   T   H   E   9   0   °   E   L   B   O   W

    T   U   B   E   I   S

   R   E   C   O   M   M   E   N   D   E   D   F   O   R   I   N   T   E   R   N   A   L

   D   R   A   I   N   I   N   S   T   A   L   L   A   T   I   O   N .

   O   V   E   R   F   L   O   W

    R   E   L   I   E   F   D   R   A   I   N

   S   E   E

   N   O   T   E   6

   S   E   E   D   E   T   A   I   L

   B   E   L   O   W

   U   S   E   T   Y

   P   E   “   A   ”   S   C   R   E   W   S   F   O   R   B   O   T   H   R   A   B   7   1   A   N   D   R   A   B   7   7

   N   U   T

   (   M   O   L   D   E   D   C   A   S   E   (   R   A   B   7   7   )   O   N   L   Y   )

   D   E   T   A   I   L

   G   A   S   K   E   T

   C   A   B   I   N   E   T   B   O   T   T   O   M

   T   U   B   E

   1   /   2   "   O   D

   C   O   V   E   R

   P   L   A   T   E

   1 .   T

    h   e   R   A   D   1   0    d   r   a    i   n    k    i   t    i   s    i   n   s   t   a    l    l   e    d    i   n   t    h   e    b   o   t   t   o   m   o    f   t    h   e   w   a    l    l   c   a   s   e   w    h   e   n    i   t    i   s    d   e   s    i   r   e    d   t   o    d   r   a    i   n

   c   o   n    d   e   n   s   a   t   e   t   o   a   n    i   n   t   e   r   n   a    l    d   r   a    i   n   s   y   s   t   e   m    i   n   t    h   e    b   u    i    l    d    i   n   g .

   2 .   T

    h   e    d   r   a    i   n    k    i   t    i   s   m   o   u

   n   t   e    d   o   n   t    h   e    b   o   t   t   o   m   o    f   t    h   e   w   a    l    l   c   a   s   e   p   r    i   o   r   t   o    i   n   s   t   a    l    l   a   t    i   o   n   o    f   t    h   e   c   a   s   e    i   n   t    h   e

   w   a    l    l .   I   t   m   a   y    b   e    l   o   c   a

   t   e    d   a   n   y   w    h   e   r   e   o   n   t    h   e   r   o   o   m   s    i    d   e   p   o   r   t    i   o   n   e   x   c   e   p   t    f   o   r   s   u    b  -    b   a   s   e    i   n   s   t   a    l    l   a   t    i   o   n   s .

   F   o   r   t    h   e   s   e   t    h   e    d   r   a    i   n

   s    h   o   u    l    d    b   e   a   t    l   e   a   s   t      "    f   r   o   m   t    h   e    i   n    d   o   o   r   e    d   g   e   o    f

   t    h   e   c   a   s   e   s   o   a   s   t   o   a    d   e   q   u   a   t   e    l   y

   c    l   e   a   r   t    h   e   s   u    b  -    b   a   s   e .

    .   A   t   e   m   p    l   a   t   e    i   s    f   u   r   n    i   s

    h   e    d   w    i   t    h   t    h   e    k    i   t    f   o   r    l   o   c   a   t    i   n   g   t    h   e   n   e   c   e   s   s   a   r   y       h

   o    l   e   s    i   n   t    h   e   c   a   s   e    b   o   t   t   o   m  -   t   w   o

   t   o   p   r   o   v    i    d   e   a   s   e   c   u   r    i   n   g   m   e   a   n   s   a   n    d   o   n   e   t   o   p   r   o   v    i    d   e   a    d   r   a    i   n    h   o    l   e    f   o   r

   t    h   e   1    /   2   "   o    d   t   u    b    i   n   g .

    (   S   e   e    d   e   t   a    i    l   s   a   t    l   e    f   t    )

   4 .   A   t   u    b   e   o   r    h   o   s   e   1    /   2   "   I .   D .    (   O

    b   t   a    i   n   e    d    l   o   c   a    l    l   y    )   m   u   s   t    b   e    i   n   s   t   a    l    l   e    d   o   n   t    h

   e    d   r   a    i   n   t   u    b   e   a   n    d   c   o   n   n   e   c   t   e    d

   t   o   t    h   e    i   n   t   e   r   n   a    l    d   r   a    i   n   s   y   s   t   e   m    i   n   t    h   e    b   u    i    l    d    i   n   g .

   5 .   W

    i   t    h   t    h   e   R   A   D   1   0   t    h   e   t   w   o   s   q   u   a   r   e    d   r   a    i   n    h   o    l   e   s    i   n   t    h   e    b   o   t   t   o   m   o   u   t   e   r

    f    l   a   n   g   e   o    f   t    h   e   w   a    l    l   c   a   s   e   a   r   e

   s   e   a    l   e    d    b   y   t    h   e   g   a   s    k   e   t   s   a   n    d   m   o   u   n   t    i   n   g   p    l   a   t   e   s   s    h   o   w   n   a    b   o   v   e .

   6 .   T

    h   r   e   e    (       )   1    /   2   "    d    i   a   m

   e   t   e   r    h   o    l   e   s    l   o   c   a   t   e    d   1    /   4   "   a    b   o   v   e   t    h   e   c   a   s   e    b   o   t   t   o   m    i   n   t    h   e    b   o   t   t   o   m   o   u   t   e   r    f    l   a   n   g   e

   p   r   o   v    i    d   e   o   v   e   r    f    l   o   w    d   r   a    i   n   a   g   e   t   o   t    h   e   o   u   t    d   o   o   r   s   w    h   e   n   w    i   n    d    d   r    i   v   e   n   r   a    i   n   e   n   t   e   r   s   t    h   e   c    h   a   s   s    i   s .

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 37/60

ge.com

Ducted Installations

2800 and 800 Series Zoneline units may be usedin ducted installations.With a ducted installation it is possible to condition theair in two areas that have a common wall separatingthem. A special adapter mounts on the wall case and atransition piece directs the air from the unit into theadapter. Instructions for mounting the adapter to the wall

case are included with the duct adapter. The adaptercontains agrille that allows air from the unit to be discharged into theprimary room and the adapter connects to a duct extensionthat allows the air to flow to the adjoining room. Ductinga unit may allow a single unit to be used rather than aseparate unit in each room, providing a means of reducinginitial equipment cost. The duct may extend a total of 15feet (with a field fabricated insulated duct extension) in onedirection, either to the right or to the left of the unit. A bafflein the adapter allows up to 50% of the discharge air to bedelivered to the secondary room.

The installation of the wall case and sub-base, if used, is thesame for units being ducted as for free-standing units. Theduct adapter support bracket overlaps the wall case by 1"and the bracket and mounting screws add approximately/8" (/16" on each side) to the width of the wall case. If less than 1" of the wall case projects into the room it willbe necessary to allow for the additional width in theopening for the wall case. The duct adapter mountingbrackets should be mounted prior to installing the case inthe wall.

Refer to pages 8 and 9 for drawings of ductedinstallations.

Prior to the installation of the transition from the roomcabinet to the adapter, it will be necessary to remove thedischarge grille from the room cabinet. Instructions for thismodification are included with the duct adapter.

New Ducted Installations

ComponentsDuct Adapter RAK6052 — The duct adapter is securedto each side of the wall case and requires the drilling of 

mounting holes in the wall case during installation. Atemplate for the hole location is in the installationinstructions. By securing the duct adapter to the wall case,the chassis retains the slide-out feature for servicing afterthe transition piece is removed.

Duct Extension RAK601 — This kit contains a 44"-longinsulated duct, a register mounting collar, and an air supplyregister. It can be secured to the duct adapter at either endof the adapter. This duct may be cut at any dimension andused in two applications providing the sum of the two ductlengths necessary do not exceed the 44" length. Even insingle applications the mounting flange must be cut off 

one end of the duct to accept the collar and supply register

Mounting Collar and Supply Register RAK602 —Thesecomponents are included in the Duct Extension Kit RAK601

They may be ordered separately for installations where twoduct extensions are made from one RAK601.

Ducted Application Considerations

When designing a ducted application some applicationconsiderations to be made include:

1. Do not exceed the 15-foot length maximum for theduct extension. Field supplied duct extension must becompletely insulated with minimum of 1/2" insulation

2. The duct must be a straight run. Turns or bends in theduct extension create air pressure drops that the unit isnot designed to overcome.

. Minimum recommended clearance between the unit andthe adjacent wall is 2".

4. Provisions for return air must be made to allow aircirculation from secondary room. Doors in both secondarand primary rooms may be undercut or a return grillemay be installed through a common wall.

5. When calculating the heat gain/heat loss take both areainto consideration.

Replacements of Existing Ducted Unit

Since the design of the Zoneline chassis has changed over

the years to provide better performance and appearance,some of the components used in ducted applications havechanged. Select the proper components from the informatiobelow. The best procedure in determining the correct kit is tmeasure duct extension cross section.

Flat Top-Discharge Units (Zoneline Units Built Prior

to 1988)

Existing Duct Extension Cross Section Measurements:8-/8" height x 6-1/2" width

Duct Adapter RAK7012 — This duct adapter will allow thereplacement of a new chassis (2800 or 800 Series unit)into an existing ducted application. This adapter will alignproperly with the duct extension and will eliminate the neeto modify the wall opening. In order to minimize replacemecosts, some of the components of the old duct adapter musbe removed and used in the new installation. Consult theInstallation Instructions of the RAK7012 before removing andiscarding the old duct adapter. See additional notes page 5

Slope-Front Discharge Units(Models With AZC, AZR, AZW, or AZ21 or AZ1 Prefix)

Existing Duct Extension Cross Section Measurements:7-/2" height x 6-1/2" width

Duct Transition RAK7022 — This duct transition will allow threplacement of a new slope-front discharge Zoneline chass(2800 or 800 Series unit) into a previous design slope-fronducted installation. See additional notes page 58.

Duct Adapter RAK6052

RAK601 DuctExtension,Mounting Collarand Register

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 38/608

   D   U   C   T   E   D   A

   P   P   L   I   C   A   T   I   O   N    (   A   Z   2   8   0   0    /      8   0   0   S   E   R   I   E   S    )

   4   4   "

   D   U   C   T   A   D   A   P   T   E   R   E   X   T   E   N   S   I   O   N   H   A   S   1   /   2   "

   I   N   S   U   L   A   T   I   O   N

   N   o   t   e   s   :

   1 .   R   A   K   6   0   5   2    k    i   t    i   n   c    l   u    d   e   s    d   u   c   t   a    d   a

   p   t   e   r ,   t   r   a   n   s    i   t    i   o   n   a   n    d   m   o   u   n   t    i   n   g    h   a   r    d   w   a   r   e .

   2 .   R   A   K   6   0   1    d   u   c   t   e   x   t   e   n   s    i   o   n   m   a   y    b   e    i   n   s   t   a    l    l   e    d   a   t   e    i   t    h   e   r   e   n    d   o    f   t    h   e   R   A   K   6   0   5   2    d   u   c   t   a    d   a   p   t   e   r .

   M   a   x    i   m   u   m    d   u   c   t   e   x   t   e   n   s    i   o   n    l   e   n   g   t    h    i   s   1   5   ' .   D   u   c   t   e   x   t   e   n   s    i   o   n   m   u   s   t    b   e    f    i   e    l    d    f   a    b   r    i   c   a

   t   e    d    f   o   r

    i   n   s   t   a    l    l   a   t    i   o   n   s   w    h   e   r   e    l   e   n   g   t    h   o    f    d   u   c   t   e   x   c   e   e    d   s    l   e   n   g   t    h   o    f   R   A   K   6   0   1    (   4   4   "    ) .   F    i   e    l    d    f   a    b   r

    i   c   a   t   e    d

    d   u   c   t   e   x   t   e   n   s    i   o   n   m   u   s   t    b   e    i   n   s   u    l   a   t   e    d   t   o   p   r   e   v   e   n   t   c   o   n    d   e   n   s   a   t    i   o   n    f   r   o   m    f   o   r   m    i   n   g   o   n

   e   x   t   e   r    i   o   r .

   D   u   c   t   e   x   t   e   n   s    i   o   n   m   a   y   n   o   t   c   o   n   t   a    i   n    b   e   n    d   s   o   r   t   u   r   n   s .

    .   D   u   c   t   e    d   u   n    i   t   s   m   a   y   n   e   e    d   t   o    b   e   p

   e   r   m   a   n   e   n   t    l   y   c   o   n   n   e   c   t   e    d .   C

    h   e   c    k    l   o   c   a    l   c   o    d   e    f   o   r

   s   p   e   c    i    f    i   c

   e    l   e   c   t   r    i   c   a    l    i   n   s   t   a    l    l   a   t    i   o   n   r   e   q   u    i   r   e   m

   e   n   t   s .

   4 .   D   u   c   t   e   x   t   e   n   s    i   o   n    k    i   t   R   A   K   6   0   1   c   o   n

   t   a    i   n   s   4   4   "    d   u   c   t   e   x   t   e   n   s    i   o   n ,    d

    i   s   c    h   a   r   g   e   g   r    i    l    l   e   m   o   u   n   t    i   n   g

   c   o    l    l   a   r ,   a   n    d    d    i   s   c    h   a   r   g   e   g   r    i    l    l   e .   D   u   c

   t   e   x   t   e   n   s    i   o   n   m   u   s   t    b   e   c   u   t   t   o   r   e   q   u    i   r   e    d    l   e   n   g   t    h .   T   w

   o    d   u   c   t   e    d

    i   n   s   t   a    l    l   a   t    i   o   n   s   m   a   y    b   e   m   a    d   e    f   r   o   m

   o   n   e    k    i   t    i    f   t    h   e   c   o   m    b    i   n   e    d    d   u   c   t   e    d    l   e   n   g   t    h    i   s    l   e   s   s

   t    h   a   n   4   4   " .

   R   A   K   6   0   2    k    i   t   c   o   n   t   a    i   n   s   m   o   u   n   t    i   n   g

   c   o    l    l   a   r ,    d    i   s   c    h   a   r   g   e   g   r    i    l    l   e   a   n    d   m   o   u   n   t    i   n   g    h   a   r    d   w   a

   r   e

   n   e   c   e   s   s   a   r   y    f   o   r   s   e   c   o   n    d    i   n   s   t   a    l    l   a   t    i   o   n .

   5 .   F

    i    l    l   e   r   s   t   r    i   p    (    f    i   e    l    d   s   u   p   p    l    i   e    d    )   a   c   t   u   a    l   w    i    d   t    h    d   e   p   e   n    d   s   u   p   o   n   w   a    l    l   c   a   s   e   p   r   o    j   e   c   t    i   o   n    i   n

   t   o   r   o   o   m .

   A    f    l   u   s    h    i   n   s   t   a    l    l   a   t    i   o   n   t   o    f    i   n    i   s    h   e    d   w   a    l    l    (   I .   E . ,   N   o    f    i    l    l   e   r   s   t   r    i   p    )   c   a   n    b   e   m   a    d   e .

   6 .   U   n    i   t   m   u   s   t    b   e    i   n   s   t   a    l    l   e    d   t   o   p   r   o   v    i    d

   e   a   t    l   e   a   s   t   a   2   "   c    l   e   a   r   a   n   c   e    b   e   t   w   e   e   n   s    i    d   e   o    f   u   n    i   t

   a   n    d   w   a    l    l .

   7 .   P   r   o   v    i   s    i   o   n   s    f   o   r   r   e   t   u   r   n   a    i   r   m   u   s   t    b   e   m   a    d   e    i   n   o   r    d   e   r   t   o   a    l    l   o   w   a    i   r   c    i   r   c   u    l   a   t    i   o   n    f   r   o   m   s   e   c   o   n    d   a   r   y

   r   o   o   m .   D   o   o   r   s    i   n    b   o   t    h   s   e   c   o   n    d   a   r   y

   a   n    d   p   r    i   m   a   r   y   r   o   o   m   s   m   a   y    b   e   u   n    d   e   r   c   u   t   o   r   a   r   e   t   u   r   n   g   r    i    l    l   e

   m   a   y    b   e    i   n   s   t   a    l    l   e    d   t    h   r   o   u   g    h   c   o   m   m

   o   n   w   a    l    l .

   8 .   F   o   r   r   e   p    l   a   c   e   m   e   n   t   o    f   p   r   e   v    i   o   u   s    d   e   s    i   g   n   u   n    i   t   s ,   s   e   e   p   a   g   e   s      7   a   n    d   5   8 .

   R   A   K   6   0   1

   4   4   "   L   E   N   G   T   H

   R   A   K   6   0   5   2

   A   D   A   P   T   E   R

   T   R   A   N   S   I   T   I   O   N

   8   "   h   i  g   h

   R   E   C   O   M

   M   E   N   D   E   D

   M   I   N   I   M

   U   M

   C   L   E   A   R

   A   N   C   E

   2   "   T   O   S

   I   D   E   W   A   L   L

     7   -     3     /     8     "      w    i     d

    e

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 39/60

ge.com

   D   U   C   T   E   D   D   E   T   A   I   L   E   D   S   I   D   E   V   I   E   W   S    (   A   Z   2   8   0   0    /      8   0   0   S   E   R   I   E   S    )

   S   e   e   p   a   g   e      8    f   o   r   a    l    l   n   o   t   e   s

   L    i   n   e   C   o   r    d   I   n   s   t   a    l    l   a   t    i   o   n

   C   A   U   L   K   *

   S   u    b  -   B   a   s   e   I   n   s   t   a    l    l   a   t    i   o   n

   A   N   Y   C   O   N   S   T   R   U   C   T   I   O   N

   1   2  -   3   /   4   "

   M   A   X .

   6  -   1   /   2   "

   1   0   "

   7  -   3   /   3   2   "

   R   A   K   6   0   5

   2

   A   D   A   P   T   E

   R

   1   6  -   1   /   8   "

   T   R   A   N   S   I   T   I   O   N

   R   O   O   M

   C   A   B   I   N   E   T

   3   /   4   "   M   I   N .

   W   A   L   L   T   O

   C   A   S   E   E   D   G   E

   W   A   L   L   C   A   S   E

   F   I   N   I   S   H   E   D

   F   L   O   O   R

   R   E   C   E   P   T   A   C   L   E

   (   B   Y   O   T   H   E   R   S

   A   L   T .   L   O   C   A   T   I   O   N   S   )

   C   A   U   L   K   *

   R   A   G   6   0

  -   1   /   4   "

   R   A   G   6   1  -   6   6

  -   1  -   3   /   8   "

   *   C  a  u   l   k  a  r  o  u  n   d  p  e  r   i  m  e   t  e

  r  o   f  w  a   l   l  c  a  s  e  a   l   l   f  o  u  r  s   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s   t   h  e   b  u   i   l   d   i  n  g  -   I  n   t  e  r   i  o  r  a  n   d   E  x   t  e  r   i  o  r .

   1   /   4   "

   M   I   N .

   2  -   2   9   /   3   2   "

   *   2  -   3   /   8   "  m   i  n .  w   h  e  n   i  n  s   t  a   l   l  e   d  w   i   t   h   R   A   K   2   0   4 .

   R   A   G   6   0

  -   1   /   4   "

   R   A   G   6   1  -   6   6  -   1  -   3   /   8   "

   3  -   1   1   /   1   6   "

   R   A   K

   2   0   4

   3   "   M   I   N .

   5   "   M   A   X .

   F   I   N   I   S   H   E   D

   F   L   O   O   R

   1   6  -   1   /   8   "

   T   R   A   N   S   I   T   I   O   N

   R   O   O   M

   C   A   B   I   N   E   T

   W   A   L   L   C   A

   S   E

   C  a  u   l   k  a  r  o  u  n   d

  p  e  r   i  m  e   t  e  r  o   f

  w  a   l   l  c  a  s  e  a   l   l

   f  o  u  r  s   i   d  e  s

  w   h  e  r  e   i   t   j  o   i  n  s

   t   h  e   b  u   i   l   d   i  n  g

  -   I  n   t  e  r   i  o  r  a  n   d

   E  x   t  e  r   i  o  r .

   2  -   2   9   /   3   2   "

   7  -   3   /   3   2   "

   R   A   K   6   0   5   2

   A   D   A   P   T   E   R

  F I  L  L  E   R   S   T   R I   P (   S  E  E   N   O   T  E  5   O   N   P   A   G  E  3  6 )

   6  -   1   /   2   "

   1   1  -   1   /   8   "

   M   A   X

 .

   2  -   3   /   8   "   *

   M   I   N .

   1   /   4   "

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 40/6040

Exterior Grilles

Four styles of outdoor grilles are available for exteriortreatments. The standard stamped aluminum grille (RAG60),the molded architectural louvered exterior grilles (RAG61-6),the molded architectural louvered exterior grilles with f lange(RAG64-66), and the extruded aluminum architecturallouvered grille (RAG67). All grilles include air deflectorsand gaskets to prevent condenser air recirculation.

RAG67

RAG60Outdoor Grille

RAG64Outdoor Grille

RAG60 Outdoor Grille — The standard exterior grille is madeof durable aluminum to protect chassis components andprevent air recirculation.

RAG61, 62, 6 Architectural Grille — One-piece optionalmolded grille and frame assembly provides improvedappearance, protection and weatherability. Molded of durable polycarbonate, the surfaces of the grille have acolorfast, slightly textured finish which blends well withmost types of wall surfaces. The grilles can be painted in

the field to match the building for improved aesthetics.

RAG64, 65, 66 Architectural Grille with Flange — Identical toRAG61-6 grilles with the addition of a 1/2" flange around thetop and sides to help conceal the juncture of the RAB71 wallcase and the wall opening. The best appearance is achievedwith this grille when the wall case extends minimally (between1/4" and 1/2") beyond the exterior face of the building.

Colors: RAG61 and 64 — Beige; RAG62 and 65 — Dark MapleRAG6 and 66 — Bittersweet Chocolate.

RAG67 Extruded Aluminum Grille — The RAG67 is made fromextruded anodized aluminum for use where an aluminumarchitectural grille is preferred. The RAG67 is available in aclear finish and may be special ordered from GE in othercolors. Minimum order quantities may be required. Contact your General Electric salesperson for details.

All grilles are installed and secured to the wall case from theinside. Keyhole slots in the rear flange of the case allow thegrille to be placed in position before securing it firmly to thewall case.

Replacement of existing units: If an existing grille is notreplaced, capacity and efficiency will be reduced and theunit may fail to operate properly or fail prematurely. Adeflector kit, RAK40, may be used with grilles that werenot designed for current AZ Series GE Zoneline units. TheRAK40 contains air deflectors and gaskets that mount tothe chassis to direct the hot exhaust air away from the airintake to allow the unit to function properly. All grilles usedwith GE Zoneline® units must comply with requirementsof Exterior Architectural Treatments and Special OutdoorGrilles as follows.

RAG61Outdoor Grille

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 41/604

ge.com

The architectural design of a building may dictate the useof special or oversized louvers for aesthetic reasons. Louversother than standard Zoneline exterior grilles may be usedon the Zoneline unit, however, these special louvers, or anyspecial exterior architectural treatments of the buildingfacade that may restrict the free circulation of condenserairflow, should be referred to GE Application Engineering forevaluation and approval. The following guidelines should befollowed in selecting a louver:

1. The louver must have a minimum of 65% free area.ASHRAE defines free area as the minimum area of theopening in an air inlet or outlet through which air canpass. Percent (%) free area equals the X dimension dividedby the Y dimension.

2. The louver should be attached to the wall case in a mannerthat will prevent recirculation of condenser discharge airinto the air inlet. If the louver is not attached directly tothe wall case, a field supplied splitter or gasket is required

between the chassis and the louver to prevent recirculation.

It is important that the above criteria be followed sincea louver that is too restrictive or allows recirculation willreduce the unit’s capacity and efficiency, increase theelectrical current draw, cause intermittent operation due tothe compressor overload protector shutting the compressoroff, and cause failure of the compressor overload andshorten compressor life. Using the unit with a grille thatis too restrictive or allows recirculation may constituteimproper installation. A scale drawing of the louver sectionshould be sent to GE Application Engineering. To assure theproper performance of the Zoneline unit and comply with

Underwriters Laboratories requirements, it may be necessaryto send a sample louver section (at least 16" x 42") to GE to betested with the Zoneline unit.

Sample Calculations

Free Area (%) =x

 yx 100 x = 1" y = 1.5"

F.A. % =1

1.5x 100 = 66.7%

Exterior Architectural Treatments

and Special Outdoor Grilles

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 42/6042

Power Connection for 2800, 800

and 5800 Series Zonelines

All 2800, 800, and 5800 Series Zonelines are equipped withuniversal heaters allowing chassis installation flexibility. TheZoneline® units are connected to the building power supplyby a unique power connection kit. By utilizing a separateuniversal power connection (UPC) kit, each unit is capable of providing various outputs of electric resistance heat to more

closely meet the heating requirements of the particular room,thereby increasing the installation flexibility of the particularchassis. This power connection kit is the only means of supplying power to the Zoneline chassis. The appropriatekit is determined by the voltage, the means of electricalconnection, either line cord connected or permanentlyconnected, and the desired resistance heat output thatmay be supported by the branch circuit.

20/208-Volt Line-Cord Connected Units

Line Cord Kits consist of a self-aligning nine-pin moldedconnector that plugs into a mating connector on the Zonelinechassis and insulated line cord with an electrical plug onthe end. The configuration of the electrical plug conformsto NEC standards for the circuit amperage and the positionof the wires in the nine-pin connector determines the heaterwattage and current requirements when it is plugged intothe Zoneline chassis.

The power connection kit is selected by the amperage of the circuit where it will be installed. Each line cord kit has anintegral Leakage Current Detection and Interruption (LCDI) orArc Fault Current Interrupter (AFCI) device as required by theNational Electrical Code (NEC) and Underwriters Laboratory(UL) for line-cord connected air conditioners manufacturedon or after August 1, 2004. The line-cord power connectionkits are shown in the table below.

20/208-Volt Line-Cord Connected Units

Line CordKit

ElectricHeatBTUH

ElectricHeaterWatts

ElectricHeatAmps

Min. CircuitProtection

(Amps)

RAK15 8600/7100 2550/2090 11.6/10.6 15

RAK20 11700/9600 450/2820 15.5/14.1 20

RAK0 17000/1900 5000/4090 22./20. 0

Electric Heat Amps include electric he ater and fan motor current draw.

20/208-Volt — Permanently Connected Units

Permanently connected units do not require the LCDI or AFCIdevice. Permanent connection is usually made through the

use of a sub-base. Each 20/208-volt sub-base consists of a sub-base with appropriate receptacle for minimum circuitamperage, a chaseway to route power connector from thesub-base to the chassis, wiring to connect the sub-baseto building wiring and a short-line cord with a self-aligningnine-pin connector to connect to chassis and plug into thereceptacle in the sub-base. Permanent, or direct wired,installation of a 20/208-volt unit requires a junction box kit,RAK4002A, which attaches to the chassis to form an enclosed junction box.

The short sub-base line cord may not be used without thesub-base.

For 2800 and 800 Series 20/208-volt units where apermanent installation using flexible conduit is desired, theRAK4002A forms an enclosed junction box on the chassis.The RAK4002A has a 7/8" diameter hole to allow conduit tobe connected to the junction box. A line cord kit, shown aboveunder Line-Cord Connected units, must be purchased and

modified to allow direct connection to the building wiring.The line cord kit should be cut about 8" from the nine-pinconnector. Strip insulation off 5/8" of each conductor toexpose wires for field connection. These wires are thenconnected to the building wiring by field-supplied connectors.

For 5800 Series 20/208-volt units, the permanent installationusing flexible conduit procedure is the same as for the 2800and 800 Series units, except the junction box kit is RAK4002B.

Electric Heat Amps include electric heater and fan motor current draw.

Each 265-volt sub-base kit consist s of a sub-base with appropriate receptacle for minimum circuitamperage, a chaseway to route the power connector from the s ub-base to the chassis and wiringto connect the sub-base to the building wiring.

The 265-volt power connection kit must be ordered separately.

All wiring must conform to local electrical regulationsand codes.

 

265 Volt Sub-Base and Direct Connected Units

Sub-BasePower

ConnectionKit

DirectConnection

Kit

ElectricHeatBTUH

ElectricHeaterWatts

ElectricHeatAmps

Min. CircuitProtection

(Amps)RAK204E15 RAK5172 RAK5157 8600 2550 9.6 15

RAK204E20 RAK5202 RAK5207 11700 450 1.0 20

RAK204E0 RAK502 RAK507 17000 5000 18.9 0

20/208 Volt Sub-Base and Direct Connected Units

Sub-Base

Direct

ConnectionKit

Electric

HeatBTUH

Electric

HeaterWatts

Electric

HeatAmps

Min. Circuit

Protection(Amps)

RAK204D15P RAK4157 8600/7100 2550/2090 11.6/10.6 15

RAK204D20P RAK4207 11700/9600 450/2820 15.5/14.1 20

RAK204D0P RAK407 170100/1900 5000/4090 22./20. 0

Electric Heat Amps include electric heater and fan motor current draw.

265- or 277-Volt Unit Installation — PermanentlyConnected Units

National Electric Code (Article 440 Section G) requirespermanent connection for units connected to power sourcesover 250 volts; therefore these units must be permanentlyconnected (direct wired) with field-supplied connectors.Units connected using a sub-base meet the requirement

for permanent connection since all wiring is internal wiringbetween the sub-base and the chassis.

Since 265-volt units may not be line cord connected, an LCDIdevice is not required.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 43/604

ge.com

Type Mfg Part No Configuration

15 AMPTandem

NEMA6-15R

HubbellP&S

56615661

20 AMPPerpendicular

NEMA6-20R

HubbellP&S

54615871

0 AMPLarge Tandem

NEMA6-0R

HubbellP&S

90590

Essential Elements Ordering Overview

RAK4002AWiring harness can be ordered separately as RAK4002CW.

20/208-volt line-cord connected units — order line cord kit.

20/208-volt sub-base connected units — order sub-base(includes power connection kit) and junction box for chassis.

265-volt units — order sub-base and power connectionkit separately.

Electrical Wiring Information –2800/800/5800 Series

All Zonelines are single-phase 60 hertz units.

For all installations, the feeder, sub-feeder, branch circuit andelectrical protective devices and selection must conform tothe National Electrical Code and to local codes.

Maximum connected load in amperes, including demandsfor the electric heater and the fan motor, are shown on page44. Branch circuit ampacity and electrical protective devicesizing are shown on page 42 for 20/208-volt units and onthis page for 265-volt units.

More than one unit per branch circuit is not recommended.When in doubt, consult the National Electrical Code. Allwiring, including installation of receptacle, must conformto local electrical regulations and codes.

Replacement of Existing Chassis

20/208-Volt and 265-Volt Units

There have been changes to NEC and improvements andmodifications to the Zoneline chassis and sub-bases sincethe unit was f irst introduced. Some of these changes requirealterations to be made when replacing an older unit with a

new chassis.

Line-Cord Connected Units

The plug configuration of new line cord connected unitscomplies with the current NEC standards. Older installationsmay have wall receptacles that conformed to NEC standardsat the time the building was constructed and may not matchthe configuration of the plug on the new line cord. Therecommended solution is to change the wall receptacle toconform to current standard plug configuration. See charton this page for current receptacle configuration.

Permanent Connected Units With Sub-Base

If the existing unit is connected to a sub-base the installationof the new unit may involve modifying the existing installatioslightly. It is recommended these modifications be made by aqualified electrician.

If the existing sub-base is the full width of the wall case,RAK201 sub-base access plate may be ordered and used

to replace the cover on the old sub-base. Field-suppliedwiring, conduit and conduit connectors should be used tomake a connection between the new chassis and the centeknockout of the RAK201. The wiring connections should bemade inside the sub-base and the RAK201 attached to thesub-base with the two screws provided.

If the existing sub-base is not the full width of the wall casthe electrician will have to modify the existing cover plate tallow field-supplied wiring, conduit and conduit connectors tbe run from the permanent connection kit to the sub-base.

Typical Line CordPower Connection KitRAK20 shown

58"

21"

Inside

Maximum Cord Extension

Receptacle

Enclosure cover removed.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 44/6044

Maximum Connected Load

The maximum connected load of a Zoneline® unit occurs when the unit is in resistance heating operation. The maximumamperage shown in the tables below is the combined total of the resistance heater and the indoor fan motor.

20/208-Volt Line Cord Connected Units

Power Connector Kit

RAK15 RAK4157

RAK204D15P

RAK20 RAK4207

RAK204D20P

RAK0RAK407

RAK204D0P

MODELNUMBER

20 V 208 V 20 V 208 V 20 V 208 V

AZ28E07DA* 11.5 10.5 15.5 14.1 N/A N/A

AZ28E09DA* 11.5 10.5 15.5 14.1 22. 20.

AZ28E12DA* 11.6 10.6 15.5 14.1 22. 20.

AZ28E15DA* 11.6 10.6 15.6 14.2 22.4 20.4

AZ8H07DA* 11.5 10.5 15.5 14.1 N/A N/A

AZ8H09DA* 11.5 10.5 15.5 14.1 22. 20.

AZ8H12DA* 11.6 10.6 15.5 14.1 22. 20.

AZ8H15DA* 11.6 10.6 15.6 14.2 22.4 20.4

AZ58H07DA* 11.5 10.5 15.5 14.1 N/A N/A

AZ58H09DA* 11.5 10.5 15.5 14.1 22. 20.

AZ58H12DA* 11.6 10.6 15.5 14.1 22. 20.

AZ58H15DA* 11.6 10.6 15.6 14.2 22.4 20.4

*All versions

Electric Heat Amps include electric heater and fan motor current draw.Values shown in table above are also the total connected loads for units installed with sub-bases.RAK204D15P — same as RAK15RAK204D20P — same as RAK20RAK204D0P — same as RAK0

265-Volt Units

Sub-Base/Power Connector Kit

RAK204E15RAK5172RAK5157

RAK204E20RAK5202RAK5207

RAK204E0RAK502RAK507

MODELNUMBER

265 V 265 V 265 V

AZ28E07EA 10.2 1.7 N/A

AZ28E09EA* 10.2 1.7 19.6

AZ28E12EA* 10. 1.7 19.6

AZ28E15EA* 10. 1.7 19.6AZ8H07EA* 10.2 1.7 N/A

AZ8H09EA* 10.2 1.7 19.6

AZ8H12EA* 10. 1.7 19.6

AZ8H15EA* 10. 1.7 19.6

AZ58H07EA* 10.2 1.7 N/A

AZ58H09EA* 10.2 1.7 19.6

AZ58H12EA* 10. 1.7 19.6

AZ58H15DA* 10. 1.7 19.6

*All versionsElectric Heat Amps include electric heater and fan motor current draw. 

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 45/604

ge.com

Cooling Performance Data

Zoneline 2800 & 800 Series Zoneline 2800 Dry Air 25 Zoneline 5800 SeriesNominal Capacity Nominal Capacity Nominal Capacity

Temperature of AirEntering Condenser

7000 9000 12000 15000 7000 9000 12000 7000 9000 12000 15000

75 7750 9950 12950 15850 7400 9500 12250 7750 9950 12950 1585082 7500 9700 12600 15500 7200 9200 11900 7500 9700 12600 15500

85 7400 9500 1250 1500 6950 9050 11750 7400 9500 1250 1500

95 7100 9000 11700 14600 6800 8600 11200 7100 9000 11700 14600

105 6700 8400 11000 1600 6400 8100 10600 6700 8400 11000 1600

115 600 7800 10400 1200 6000 7650 10000 600 7800 10400 1200

Total Capacity - BTUH

BTUH at 80º F D.B. - 67º F W.B.

Heat Pump Performance Data

Capacities and COP at Various Outdoor Temperatures

BTUH at 70º F Indoor Temperature

Zoneline 800 SeriesOutdoor

Temperature F7000 9000 12000 15000

65 7500 .85 10000 .85 12950 .65 15950 .45

60 7200 .80 9600 .80 12500 .60 1500 .40

55 6900 .75 9100 .75 11850 .55 14650 .5

50 6600 .65 8700 .65 1100 .45 1850 .25

47 6400 .60 8400 .60 10900 .40 1400 .20

45 6250 .55 8200 .55 10600 .5 1050 .15

40 5950 .45 7700 .45 9800 .20 12250 .05

5 5600 .5 7100 .5 9200 .10 1100 2.95

0 5250 .20 6500 .20 800 .00 1000 2.85

25 4700 .05 5900 .05 7500 2.85 9250 2.75All data at 20 volts and 265 volts.

Zoneline 5800 SeriesOutdoor

Temperature F7000 9000 12000 15000

65 7500 .85 10000 .85 12950 .65 15950 .45

60 7200 .80 9600 .80 12500 .60 1500 .40

55 6900 .75 9100 .75 11850 .55 14650 .5

50 6600 .65 8700 .65 1100 .45 1850 .25

47 6400 .60 8400 .60 10900 .40 1400 .20

45 6250 .55 8200 .55 10600 .5 1050 .15

40 5950 .45 7700 .45 9800 .20 12250 .055 5600 .5 7100 .5 9200 .10 1100 2.95

0 5250 .20 6500 .20 800 .00 1000 2.85

25 4700 .05 5900 .05 7500 2.85 9250 2.75All data at 20 volts and 265 volts.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 46/6046

Latent System Capacity

The total capacity of an air conditioner is made up of theSensible capacity, the output of the unit used to removeheat from the air in the area being conditioned, and theLatent capacity, the output of the unit used to dehumidifythe air in the area being conditioned. For humid climatesand applications, the Sensible/Latent capacity split of theunit should be considered. The Sensible capacity listed in

the specification charts on page 55 is at a standard ratingcondition of 95°F dry bulb/75°F wet bulb outdoors; 80°F drybulb/67°F wet bulb indoors. The Latent system capacity is

1.00 minus the Sensible capacity. (If the Sensible capacity islisted at .74 the Latent capacity is .26. This means that 74% of the capacity of the unit is used to remove heat from the airand 26% is used to remove moisture form the air at standardtest conditions.)

In some applications information about the Sensible/Latentsplit, or ratio, at conditions other than the standard rating

conditions is needed. The chart below provides data atvarious indoor conditions.

MODELIndoor WB

(F)Indoor Ambient DB Temperature (F)

60 65 70 75 80 85 90 95 100

All 7000 BTUH 59 0.51 0.67 0.8 0.99 1.00 1.00 1.00 1.00 1.00

units except 6 0.46 0.62 0.77 0.92 1.00 1.00 1.00 1.00

Dry Air 25 67 0.42 0.60 0.75 0.88 1.00 1.00 1.00

71 0.42 0.54 0.66 0.78 0.90 1.00

AZ28E07DAP/EAP 59 0.8 0.49 0.65 0.80 0.95 1.00 1.00 1.00 1.00(Dry Air 25) 6 0.8 0.54 0.68 0.80 1.00 1.00 1.00 1.00

67 0.5 0.52 0.66 0.79 0.92 1.00 1.00

71 0.2 0.45 0.58 0.7 0.85 1.00

All 9000 BTUH 59 0.42 0.59 0.77 0.9 1.00 1.00 1.00 1.00 1.00

units except 6 0.40 0.55 0.70 0.8 0.96 1.00 1.00 1.00

Dry Air 25 67 0.42 0.55 0.68 0.81 0.9 1.00 1.00

71 0.8 0.49 0.60 0.71 0.82 0.9

AZ28E09DAP/EAP 59 0.0 0.45 0.60 0.75 0.92 1.00 1.00 1.00 1.00

(Dry Air 25) 6 0.2 0.42 0.57 0.7 0.90 1.00 1.00 1.00

67 0.2 0.45 0.58 0.70 0.85 1.00 1.00

71 0.0 0.8 0.48 0.61 0.74 0.85

All 12000 BTUH 59 0.8 0.54 0.71 0.88 1.00 1.00 1.00 1.00 1.00

units except 6 0.40 0.54 0.68 0.81 0.9 1.00 1.00 1.00

Dry Air 25 67 0.41 0.54 0.67 0.80 0.9 1.00 1.00

71 0.6 0.47 0.58 0.71 0.82 0.9AZ28E12DAP/EAP 59 0.0 0.45 0.60 0.75 0.92 1.00 1.00 1.00 1.00

(Dry Air 25) 6 0.0 0.41 0.56 0.72 0.89 1.00 1.00 1.00

67 0.1 0.44 0.57 0.70 0.84 0.99 1.00

71 0.1 0.40 0.50 0.61 0.7 0.84

All 15000 BTUH 59 0.8 0.54 0.71 0.88 1.00 1.00 1.00 1.00 1.00

units except 6 0.40 0.54 0.68 0.81 9.00 1.00 1.00 1.00

Dry Air 25 67 0.41 0.54 0.67 0.80 0.9 1.00 1.00

71 0.6 0.47 0.58 0.71 0.82 0.9

Capacities are nominal capacity

Cooling Sensible Heat Ratio (SHR) at Various Indoor WB and DB Temperatures

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 47/604

ge.com

Formula for Calculating Operating Costs Using Above Data:

Normal Yearly Operating Data

(Cooling Hours based on 75°F indoor temperature with air conditioner sized to meet the design conditions.)

ASHRAEHeating EstimatedDegree Cooling

Location Days Hours

ALABAMA Birmingham 2,551 1,90

Huntsville ,070 1,40Mobile 1,560 1,640

Montgomery 2,291 1,580ARIZONA

Flagstaff 7,152 10Phoenix 1,765 2,280Tucson 1,800 1,920Yuma 974 2,520

ARKANSASFort Smith ,292 1,410Little Rock ,219 1,0

CALIFORNIABakersfield 2,122 1,50Fresno 2,611 1,210Los Angeles 2,061 10Sacramento 2,502 1,00San Diego 1,458 90San Francisco ,015 110

COLORADOColorado Springs 6,42 520

Denver 6,28 550Grand Junction 5,641 910

CONNECTICUTHartford 6,25 480

DISTRICT of COLUMBIAWashington 4,224 1,010

DELAWAREWilmington 4,90 770

FLORIDAJacksonville 1,29 1,690Miami 214 2,850Orlando 766 1,90Tallahassee 1,485 1,500Tampa 68 2,50

GEORGIAAtlanta 2,961 1,10Augusta 2,97 1,400Macon 2,16 1,440

Savannah 1,819 1,510IDAHO

Boise 5,809 670Lewiston 5,542 600Pocatello 7,0 570

ILLINOISChicago 6,155 780Moline 6,408 760Springfield 5,429 890

INDIANAEvansville 4,45 1,090Fort Wayne 6,205 710Indianapolis 5,699 820South Bend 6,49 600

IOWABurlington 6,114 70Des Moines 6,588 710Sioux City 6,951 770

KANSASDodge City 4,986 1,020Goodland 6,141 800Topeka 5,182 880Wichita 4,620 1,070

ASHRAEHeating EstimatedDegree Cooling

Location Days Hours

 

ASHRAEHeating EstimatedDegree Cooling

Location Days Hours

  KENTUCKYLexington 4,68 80Louisville 4,660 1,10

LOUISIANA

Alexandria 1,921 1,670Baton Rouge 1,560 1,860New Orleans 1,85 1,790Shreveport 2,184 1,470

MAINEPortland 7,511 290

MARYLANDBaltimore 4,654 850

MASSACHUSETTSBoston 5,64 500

MICHIGANDetroit 6,29 590Flint 7,77 440Grand Rapids 6,894 50

MINNESOTADuluth 10,000 200Minneapolis 8,82 550

MISSISSIPPI

Jackson 2,29 1,560MISSOURI

Columbia 5,046 960Kansas City 4,711 1,210Springfield 4,900 970St. Louis 4,900 1,080

MONTANABillings 7,049 520Glasgow 8,996 410Great Falls 7,750 420Missoula 8,125 50

NEBRASKAGrand Island 6,50 770Omaha 6,612 750

NEVADAEly 7,7 500Las Vegas 2,709 1,980Reno 6,2 520

NEW JERSEYNewark 4,589 710

NEW MEXICOAlbuquerque 4,48 1,040Clayton 5,158 720Silver City ,705 1,260

NEW YORKAlbany 6,875 480Binghamton 7,286 10Buffalo 7,062 450New York 4,811 790Rochester 6,748 470Syracuse 6,756 500

NORTH CAROLINAAsheville 4,042 690Charlotte ,191 1,20Raleigh ,9 1,070Winston-Salem ,595 960

NORTH DAKOTABismarck 8,851 510Fargo 9,226 490Williston 9,24 580

OHIOCincinnati 5,265 840Cleveland 6,51 610Columbus 5,660 810

Dayton 5,622 740Toledo 6,494 590

OKLAHOMAOklahoma City ,725 1,200Tulsa ,860 1,410

OREGONMedford 5,008 620Pendleton 5,127 590Portland 4,65 270

PENNSYLVANIAHarrisburg 5,251 70Philadelphia 5,144 810Pittsburgh 5,987 590Scranton 6,254 440Williamsport 5,94 600

RHODE ISLANDProvidence 5,954 470

SOUTH CAROLINA

Charleston 2,0 1,90Columbia 2,484 1,440Greenville 2,980 1,120

SOUTH DAKOTARapid City 7,45 580Sioux Falls 7,89 610

TENNESSEEChattanooga ,254 1,180Knoxville ,494 1,070Memphis ,22 1,20Nashville ,578 1,220

TEXASCorpus Christi 914 2,80Dallas 2,6 1,900El Paso 2,700 1,580Houston 1,96 1,850Lubbock ,578 1,10San Antonio 1,546 1,920

UTAHMilford 6,497 910Salt Lake City 6,052 80

VERMONTBurlington 8,269 10

VIRGINIANorfolk ,421 1,010Richmond ,865 1,020Roanoke 4,150 870

WASHINGTONSeattle 5,145 180Spokane 6,655 40Yakima 5,941 50

WEST VIRGINIACharleston 4,476 860Huntington 4,446 820

WISCONSINMadison 7,86 50

Milwaukee 7,65 450WYOMING

Casper 7,410 600Cheyenne 7,81 420Sheridan 7,680 50

Heating* —Heat Loss KW x Heating Degree Days x “C” x Cost Per KWH

= Operating CostOutdoor Design Temperature Difference

*The above formula is for electric resistance heating only. Power consumption using the Zoneline Heat Pumps should be adjusted by Seasonal Performance Factor (SPF).

The local power supplier should be consulted for recommended value of “C.” This factor will vary between 17 and 24.

Cooling —Calculated Heat Gain (BTUH)

x =Unit Cooling Watts

x Cooling Hours x Cost per KWH = Operating CostInstalled unit capacity (BTUH) 1000 Watts/KW

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 48/6048

Typical 2800 Series, 208/20-Volt Wiring Diagram

Typical 2800 Series, 208/20-Volt Schematic Diagram

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 49/604

ge.com

Typical 800 Series, 208/20-Volt Wiring Diagram

Typical 800 Series, 208/20-Volt Schematic Diagram

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 50/6050

1 2 3 4 5 6 7 8 9 10

   Y   L

   Y   L

   O   R

   O   R

   B   K

   B   K

   B   L

   B   L

   R   D

   R   D

   R   O   O   M

   I   D .   C   O   I   L

   O   D .   C   O   I   L

   O   U   T   D   O   O   R

   H   E   A   T   E   R

CN1

MAIN BOARD UNIT

   C   N   5

   C   N   2

   C   N   1   0   4

CN6 & 7 1 2

CN3

WH WH

YL

YL

BK

BK

1

2

5

7

   C   N   1   0   3

OPERATION

BOARD UNIT

CN301 & 302

TRANSFORMER

1

2BR

CN203

CN107

ICRBOARD UNIT(OPTIONAL)

   C   N   2   0   2

   C   N   2   0   1

1

3

1 3

RDRD

CN106

PMYL

YL

ICR(OPTIONAL)

RY103

RDBL

1

3

5   C   N   1   0   1DRIVE

BOARDUNIT

1

3

5   C   N   1   0   2CN8

NR101

VARISTOR

   R   Y   1   0   1

BK

RY102 RY1091

3   C   N   1   0   5

1

2

3

4

6

FM

RD

WH

BK

OROR

RD

WH

BK

BLGY

RUNNINGCAPACITOR

   I   D .   F   A   N   M   O   T   O   R

RUNNINGCAPACITOR

FMRD

WH

BK

BL

GY

OD. FAN MOTOR

RVRD*1

RD*1

REV.VALVESOLE.

CM

   R   U   N   N   I   N   G

   C   A   P   A   C   I   T   O   R

   W   H

   R   D

R

S

C B    K

     C     O    M    P    R    E     S     S     O    R

O.L.P.

6

3

5

2

4

1

2

1BK

BK

RD

RD BK

FUSE

PROTECTORHEATER UNIT

BL

WH

WH

RD

RD

BR

BK

BK

BK

RD

RD

WH

WH

HEATER

HEATER

HEATER

    R    D

    W    H

RD

GY

1 2 3 6 5 4 8 9

1 2 3 4 5 6 7 9

    B    K    B    R     G    Y    R    D     G    R    W    H

    B    L     O    R

(265V)

(208/230V)

COLOR BK : BLACKBL : BLUEBR : BROWNGR : GREENGY : GRAYOR : ORANGERD : REDWH : WHITEYL : YELLOW

RD*1 : RED (208/230V),: BLUE (265V) WH

O. L . P.

COMP.MOTOR

RUNNINGCAPACITOR

C

S

R H     E     A     T     E     R

PROTECTOR

     R     Y     1     0     2

     R     Y     1     0     9

     R     Y     1     0     3

OUTDOORFAN

MOTOR

INDOORFAN

MOTOR

FAN MOTORCAPACITOR

FAN MOTORCAPACITOR

CN102 CN101

     R     Y     1     0     6

     R     Y     1     0     7

     R     Y     1     0     4

     R     Y     1     0     5

CN8

     C     N     1     0     3

Varistor(NR101)

Capacitor(C101, C102)

FUSE(FU101)

DRIVE BOARD UNIT REGULATOR

(TR1)

     T

     R     A     N     S     F     O     R     M     E     R

CN3

MAIN BOARD UNIT

DIP SW(for setting)

INTERFACE

RY107

RY106

RY105

RY104

RY103

RY102

RY101

ROOM

ID. COIL

REMOTE T' STAT

CDC

TRANSFER FAN

MOTION SENSOR

DOOR SWITCH

   C   N   5

REVERSEVALVESOL.

CN105

   C   N   1   0   6

ICRPUMP

CN201

   R   Y   2   0   1

   I   C   R

   B   O   A   R   D

   U   N   I   T

   (   O   P   T

   I   O   N   A   L   )

   C   N   1   0   7

   C   N   2   0   3

   C   N   2   0   2

RY201

   R   Y   1   0   8

(OPTIONAL)

RY108

OD. COIL

   C   N   6   &   7

   H   E   A   T   E   R

   H   E   A   T   E   R

UNIVERSAL CONNECTOR

   H   E   A   T   E   R

   U   N   I   T

CURRENTDETECTOR (CT1)

FUSE

HEATER

   C   N   2

   C   N   1   0   4CONTROL

CIRCUIT

UP

DOWN

   T   H   E   R   M   O

FAN SPEED

AUTO

LOW

HIGH

MODE

HEAT

FAN

COOL

OPE

OPE

   O

   P   E   R   A   T   I   O   N

   B   O   A   R   D

OUTDOOR

RY109

   R   Y   1   0   1

   C   N   1

DECODER

Typical 5800 Series Wiring Diagram

Typical 5800 Series Schematic Diagram

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 51/605

ge.com

The following are suggested specifications for the Zoneline® 2800 Series Packaged Terminal Air Conditioner, the 800Series Packaged Terminal Heat Pump and the 5800 SeriesPackaged Terminal Heat Pump.

The contractor will furnish Packaged Terminal Air Conditionersof the sizes and capacities shown on the schedule and in thespecifications. The units shall be located as shown on the

drawings and each shall consist of a chassis, room cabinet,wall case, sub-base if specified, and outdoor grille.

Units shall be listed by UL, and ARI and cUL certified as tocapacity and efficiency and shall be GE Zoneline® modelsor equal. Unit dimensions shall not exceed 42-1/8" wide and16-1/4" high with room cabinet in place.

Units shall be designed to operate on (208) (20) (265) volts,60 Hz., single-phase power.

Chassis. The air conditioner chassis shall be the standardproduct of the manufacturer and shall be shipped in protectivecartons to prevent damage. Cartons shall be appropriatelymarked at the factory with wording sufficient to warn handlers

against improper stacking, up-ending, rolling or dropping.The chassis shall be the slide-in type, ready to operate afterinstallation.

Each shall consist of the following sections and components:

• Each unit shall have a matching, easily removable,textured finish, wrap-around room cabinet molded of high-temperature styrene to resist corrosion and damage. Theroom cabinet shall have slide-out washable filters accessiblewithout requiring removal of room cabinet from chassis;

• Hermetically sealed refrigerant system with externalvibration isolated rotary-type compressor, condenser andevaporator coils and capillary refrigerant control. Coolingshall be possible to outdoor temperature of 5°F withoutdamage to the compressor. Airflow system consisting of onepermanently lubricated two-speed fan motor for the outdoorfan and a separate permanently lubricated two-speed fanmotor for the indoor fan. Outdoor fan shall be multi-bladeaxial-flow design made of non-corrosive material. Indoor fanshall be of a design to optimize airflow and operating sound.All motors on the exterior side of the weather barrier shallbe of an enclosed design to reduce the effects of moistureand corrosion;

• Line-cord connected units shall require a line cord powerconnection kit with integral Leakage Current Detectionand Interruption device or Arc Fault Current Interrupteras required by National Electrical Code and Underwriters

Laboratories. The unit shall have a universal resistanceheater with output determined by connection to the powersource with the appropriate power connection kit to providespecified heat output;

• A fan-cycle switch to permit continuous fan operation orfan cycle operation, independently selectable for heatingand cooling operation;

• Fan-only operation in either high or low fan speed selectableby room occupant;

Suggested Bid Form Specifications

• A positive cooling condensate disposal system which meetthe test requirements of applicable A.R.I. Standard 10-9(for Packaged Terminal Air Conditioners) and 80-9 (forPackaged Terminal Heat Pump) (80°F dry bulb, 75°F wet bul80% relative humidity);

• Condenser and evaporator coils to be constructed of coppetubing and aluminum plate fins designed to achieve EER anCOP rating of the unit;

• Indoor and outdoor airflows that match the capacity of thecoils for efficient heat transfer. Water blow-off shall not occuon the indoor coil;

• Adjustable indoor discharge air louvers that provide a 50° overtical air pattern with an alternate position to provide a 40off vertical air pattern;

• Easily accessible controls for selection of unit operationand thermostat setting. Controls shall be covered by ahinged door;

• Air discharge area accessible for cleaning without toolswhen room front is removed for 2800 and 800 Series;

• Positive-closing, manually controlled, three-position fresh-a

vent capable of providing selection of fully open, partially opeor closed setting. Vent door is to be secured for shipping;

• Solid-state thermostat control to sense room temperature

• Electronic temperature limiting with seven independentheating and cooling settings to limit maximum and minimutemperatures without restricting movement of thermostatcontrol knob;

• Freeze Sentinel™ to automatically activate the electricresistance heater and fan motor to warm and circulate indooair to help prevent damage due to freezing temperatures.Freeze Sentinel shall operate as long as unit is connectedto powered electrical circuit and unit shall provide ability foowner to defeat the Freeze Sentinel operation;

• Heat Sentinel to automatically activate air conditioneroperation when the unit is in the STOP setting when theroom temperature warms to 85ºF and turns air conditioneoperation off when the room temperature cools to 80°F, if selected by owner;

• Compatible with two-wire Central Desk Control systems;

• Remote Thermostat compatibility with Class 2 remotethermostat;

• Connections to interface with a transfer fan to move air intanother room;

• Connections to interface with occupancy sensors;

Unit shall have means of electrical connection listed by

Underwriters Laboratories and compatible with the unit’srequired voltage and ampacity in conformance with NationaElectrical Code® (NEC) and local codes.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 52/60

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 53/605

ge.com

Suggested Bid Form Specifications

(continued)

Weather Resistance. Complete unit including outside louvershall be submitted to an independent agency for weatherresistance and water infiltration tests.

Air infiltration test to be conducted in accordance withASTM E28-91. With static air pressure differential of 

1.57 lb./ft.

2

(." H

2

O) equivalent to 25 mph wind, allowableair infiltration shall not exceed 7 ft./min.

Water infiltration test to be conducted in accordancewith ASTM E1-86 with static air pressure differential of 10.0 lb./ft2 (1.9" H2O) equivalent to 6 mph wind, 5.0 gal./ft.2 (8" rain/ft.2/hr.) for 15 minutes and there shall be no leakageinto the room.

Approvals. Units shall be certified under the ARI and cULcertification program and listed by UL.

Service. Submit complete information with bid coveringservice availability to whom service on units will be assigned,along with complete address and phone number, including

phone number of emergency service personnel.Start-Up, Adjust, Demonstrate. Contractor shall be responsiblefor the initial starting of units, adjustments thereto, etc., toplace the units in required operating condition. Contractorshall demonstrate to the owner or his representative theoperation of units for both summer and winter functions.

Warranty. The warranty shall be a full one-year parts andlabor on the entire unit, plus an additional full four yearsparts and labor for the sealed refrigerating system, includingservice call for diagnosis and transportation to and fromservice shop (if necessary) at no charge to the customer.The warranty shall also include a limited second throughfifth year parts only warranty for fan motors, switches,thermostat, heater, heater protectors, compressor overload,solenoids, circuit boards, auxiliary controls, thermistors,frost controls, ICR pump, capacitors, varistors and indoorblower bearing.

Installation Responsibility. Units shall be installedaccording to the manufacturer’s recommendations and themanufacturer shall not be responsible for unit failure as aresult of improper installation, or unit performance wheninstalled with accessories not approved by the manufacturer.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 54/6054

Zoneline® Chassis Nomenclature

EXAMPLE

Receptacles/Sub-Bases

  RAK204U RAK204D15P RAK204D20P RAK204D0P RAK204E15 RAK204E20 RAK204E0

Voltage N/A 20/208 20/208 20/208 265 265 265

Amps N/A 15 20 0 15 20 0

Receptacle N/A NEMA6-20R NEMA6-20R NEMA6-0R NEMA7-15R NEMA7-20R NEMA7-0R20/208-Volt sub-bases include appropriate power cord kit.265-Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.

Sub-Bases

Tandem20/208V 15 AmpNEMA6-15R

Perpendicular20/208V 20 AmpNEMA6-20R

Large tandem20/208V 0 AmpNEMA6-0R

265V 15 AmpNEMA7-15R

265V 20 AmpNEMA7-20R

265V 0 AmpNEMA7-0R

LCDI Power Connection Kit

Heater KW

Watts

BTUH

Amps

Min. circuit amps

Recommendedprotective

device

*To be used with sub-base

RAK15 RAK20 RAK0

2.55/2.09 .45/2.82 5.00/4.09

2,550/2,090 ,450/2,820 5,000/4,090

8,600/7,100 11,700/9,600 17,000/1,900

11.0/10.0 15.0/1.6 21.7/19.7

15 20 0

15-amp 20-amp 0-amptime-delay time-delay time-delay

fuse or breaker fuse or breaker fuse or breaker

265-volt Permanent connected units* (Cord set)

RAK5172 RAK5202 RAK502

2.55 .45 5.0

2,560 ,450 5,000

8,600 11,700 17,000

9.6 1.0 18.9

15 20 0

15-amp 20-amp 0-amptime-delay fuse time-delay fuse time-delay fuse

20/208-volt Line cord connected units

Power connection kits are required on allZoneline chassis (see chart below).The correct kit for the installation is determined by the voltage andamperage of the electrical circuit and the means of connecting theunit to the building wiring. If the unit is to be plugged into a receptacle,a line cord kit would be used; if the unit is to be permanently connected,

a permanent connection kit would be used. 265-volt cord set units mustbe installed in compliance with National Electrical Code.

Power connection kitsrequired on all models.See specification sheetfor heater KW andbranch circuit ampacity.

RAK15 and RAK2020/208-volt line cordconnection kit

RAK020/208-volt line cordconnection kit

The Zoneline chassis is identified by a model number definingthe type of unit, cooling capacity, electrical information andoptional features included on the unit. When specifying orordering the Zoneline chassis use of this nomenclature willassure receiving the correct unit.

A Z 5 8 H 1 2 D A DChassis series28=deluxe line cool/

electric heat8=deluxe line heat pump58=premium line

heat pump

Unit typeE=cooling with electric

resistance heatH=heat pump with electric

resistance heat

Zonelinepackagedterminalchassis

Nominal cooling capacity07=7,000 BTUH cooling09=9,000 BTUH cooling12=12,000 BTUH cooling15=15,000 BTUH cooling

Special FeaturesB=base unitC=corrosion treatedD=internal

condensateremoval (ICR)system (heatpump modelsonly) (not forcoastal areas)

P=Dry Air 25

Voltage/Phase/

FrequencyD=20/208 Volt, single

phase, 60 HzE=265 Volt, single phase,

60 Hz

Universalpower connection

Premium Line: 5800 Series

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 55/605

ge.com

Specifications

Deluxe series – heat pump units Premium series – heat pump units

 

265V Models AZ28E07E AZ28E09E AZ28E12E AZ28E15E AZ28E07EAP AZ28E09EAP AZ28E12EAP

Capacity

Cooling BTUH 7,100 9,000 11,700 14,600 6,800 8,600 11,200

EER (BTU/Watt) 12.7 12.0 11.5 10.2 12.1 11.5 11.0

Dehumidification Pts/Hr 1.7 2.7 .6 4.5 2.2 .4 4.5

Sensible heat ratio @ 265 volts 75% 68% 67% 67% 66% 58% 57%

CFM, indoor fan high 250 270 290 10 210 25 240

CFM, indoor fan low 215 25 240 260 175 200 210

Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 50/40 70/45 75/45

Power/Ratings

Power factor 87 86 87 90 88 86 87

Watts 560/545 750 1020 141 560 750 1020

Amperes, F.L. 2.4/.0 . 4.4 6.0 2.4 . 4.4

Amperes, L.R. 16.0 18.0 24.0 1.0 16.0 18.0 24.0

Weight (Net/Ship) 100/115 101/116 105/120 115/10 100/115 101/116 105/120

Sound Transmission Class (STC) 29 29 29 29 29 29 29

2800 series units Dry Air 25

20/208V Models AZ28E07D AZ28E09D AZ28E12D AZ28E15D AZ28E07DAP AZ28E09DAP AZ28E12DAP

Capacity

Cooling BTUH 7,100/6,900 9,00/8,900 11,800/11,500 14,600/14,00 6,800/6,600 8,600/8,400 11,200/11,000

EER (BTU/Watt) 12.7/12.7 12.0/12.0 11.5/11.5 10.2/10.2 12.1/12.1 11.5/11.5 11.0/11.0

Dehumidification Pts/Hr 1.7 2.7 .6 4.5 2.2 .4 4.5

Sensible heat ratio @ 20 volts 75% 68% 67% 67% 66% 58% 57%

CFM, indoor fan high 250 275 00 10 210 20 240

CFM, indoor fan low 215 25 240 260 175 200 210

Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 50/40 70/45 75/45Power/Ratings

Power factor 86/87 86/86 91/91 89/90 87/87 86/86 91/91

Watts 560/545 750/75 1020 140/1400 560/545 750/70 1020

Amperes, F.L. 2.8/.0 .8/4.1 4.9/5. 7.0/7.5 2.8/.0 .6/.9 4.9/5.

Amperes, L.R . 19.0 21.0 1.0 8.0 19.0 21.0 1.0

Weight (Net/Ship) 100/115 101/116 105/120 115/10 100/115 101/116 105/120

Sound Transmission Class (STC) 29 29 29 29 29 29 29

Deluxe series – cooling & electric heat Dry Air 25

 

265V Models AZ8H07E AZ8H09E AZ8H12E AZ8H15E AZ58H07E AZ58H09E AZ58H12E AZ58H15E

Capacity

Cooling BTUH 7,100 9,000 11,700 14,600 7,100 9,000 11,800 14,700

EER (BTU/Watt) 12.7 12.0 11.5 10.0 1.0 12.0 11.5 10.2Dehumidification Pts/Hr 1.7 2.7 .6 4.5 1.7 2.8 .6 4.8

Sensible heat ratio @ 265 volts 75% 68% 67% 67% 75% 67% 68% 65%

CFM, indoor fan high 250 270 00 10 240 290 0 50

CFM, indoor fan low 215 25 260 260 220 270 10 0

Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 50/40 70/45 75/45 75/45

Power/Ratings

Power factor 96 94 94 96 96 94 94 96

Watts 560 750 1020 1460 570 760 1010 1425

Amperes, F.L. 2.4 .2 4.4 6.0 2.2 .2 4.4 5.8

Amperes, L.R. 16.0 18.0 24.0 1.0 16.0 18.0 24.0 1.0

Reverse cycle heat BTUH 6,400 8,400 10,900 1,400 6,400 8,400 10,900 1,800

COP .6 .6 .4 .2 .7 .6 .4 .2

Watts 520 685 940 120 505 685 940 1,265

Amps 2.2 2.8 .9 5.0 2.2 2.7 .9 5.0

Weight (Net/Ship)* 102/117 109/124 11/128 12/18 108/122 11/128 118/1 127/142

Sound Transmission Class (STC) 29 29 29 29 29 29 29 29

*ICR adds pounds to unit weight

800 series units 5800 series units

20/208V Models AZ8H07D AZ8H09D AZ8H12D AZ8H15D AZ58H07D AZ58H09D AZ58H12D AZ58H15D

Capacity

Cooling BTUH 7,100/6,900 9,000/8,800 11,700/11,500 14,600/14,00 7,100/7,000 9,000/8,800 11,800/11,600 14,700/14,400

EER (BTU/Watt) 12.7/12.7 12.0/12.0 11.5/11.5 10.0/10.0 1.0/1.0 12.0/12.0 11.5/11.5 10.2/10.2

Dehumidification Pts/Hr 1.7 2.7 .6 4.5 1.7 2.8 .6 4.8

Sensible heat ratio @ 20 volts 75% 68% 67% 67% 75% 67% 68% 65%

CFM, indoor fan high 250 270 00 10 240 290 0 50

CFM, indoor fan low 215 250 260 260 220 270 10 0

Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 50/40 70/45 75/45 75/45

Power/Ratings

Power factor 86/87 96 97 94 95 96 94 95

Watts 560/545 750/75 1020/1000 1460/140 560/540 760/75 1010/990 1425/1400

Amperes, F.L. 2.8/.0 .8/4.1 4.9/5. 7.0/7.5 2.7/2.8 .6/.8 4.6/5.0 6.5/7.0

Amperes, L.R. 19.0 21.0 1.0 8.0 19.0 21.0 .0 8.0

Reverse cycle heat BTUH 6400/6200 8400/8200 10900/10700 1400/1200 6,400/6,200 8,400/8,200 10,900/10,700 1,800/1,800

COP .6 .6 .4 .2 .7/.7 .6/.6 .4/.4 .2/.2

Watts 520/505 685/670 940/925 120/1210 505/490 685/670 940/920 1,265/1,25

Amps 2.4/2.6 .2/.5 4./4.7 5.8/6. 2.4/2.5 .2/.4 4./4.7 5.7/6.2

Weight (Net/Ship) 102/117 109/124 11/128 1/18 108/122 11/128 118/1 127/142

Sound Transmission Class (STC) 29 29 29 29 29 29 29 29

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 56/6056

Complete Accessory List

Kit Number Description For Additional Information Refer to Page

RAA6 Spare Filters for AZ2800, AZ800 and AZ5800 Series units (10 pairs per box) 11

RAB71A Steel Wall Case – 1 /4" deep 22

RAB7116 Steel Wall Case – 16" deep 22

RAB7124 Steel Wall Case – 24" deep 22

RAB7128 Steel Wall Case – 28" deep 22

RAB711 Steel Wall Case – 1" deep 22

RAB77 Molded Wall Case 22RAD10 Interior/Exterior Drain kit 5

RAF45 Room Front for AZ2800, AZ800 and AZ5800 Series units (included with chassis) 11

RAG60 Stamped Aluminum Exterior Grille 40

RAG61 Architectural Exterior Grille, Beige Molded High-Impact Plastic 40

RAG62 Architectural Exterior Grille, Maple Molded High-Impact Plastic 40

RAG6 Architectural Exterior Grille, Bittersweet Chocolate Molded High-Impact Plastic 40

RAG64 Architectural Exterior Gri lle w/Flange, Beige Molded High-Impact Plastic 40

RAG65 Architectural Exterior Grille w/Flange, Maple Molded High-Impact Plastic 40

RAG66 Architectural Exterior Grille w/Flange, Bittersweet Chocolate Molded High-Impact Plastic 40

RAG67 Aluminum Architectural Grille (Custom Colors Available by Special Order) 40

RAK40 Condenser Air Deflector Kit 40

RAK147 Wall Thermostat For Heat Pump Models – Mechanical 16

RAK148D1 Wall Thermostat For Heat Pump Models - Electronic Digital 16

RAK148P1 Wall Thermostat For Heat Pump Models – Electronic Digital Programmable 16

RAK16A1 Wall Thermostat For Resistance Heat Models – Mechanical 15

RAK164D1 Wall Thermostat For Resistance Heat Models – Electronic Digital 15

RAK164P1 Wall Thermostat For Resistance Heat Models – Electronic Digital Programmable 15

RAK201 Sub-Base Cover Plate with Knockouts 4

RAK204D15P Sub-Base - 208/20-Volt with NEMA 6-20R 15/20 Amp Receptacle – power cord and Chaseway included 22

RAK204D20P Sub-Base - 208/20-Volt with NEMA 6-20R 15/20 Amp Receptacle – power cord and Chaseway included 22

RAK204D0P Sub-Base - 208/20-Volt with NEMA 6-0R 0 Amp Receptacle –power cord and Chaseway included 2

RAK204E15 Sub-Base – 265-Volt with NEMA 7-15R 15 Amp Receptacle – Chaseway included 2

RAK204E20 Sub-Base – 265-Volt with NEMA 7-20R 20 Amp Receptacle – Chaseway included 2

RAK204E0 Sub-Base – 265-Volt with NEMA 7-0R 0 Amp Receptacle – Chaseway included 2

RAK204U Sub-Base – non-electr ical Chaseway not included 22RAK205CW Chaseway for Sub-Base 22

RAK15 Universal Power Cord – 2800/800/5800 series – 15-Amp 20/208 V – 2.55/2.09 kW heat 42

RAK20 Universal Power Cord – 2800/800/5800 – 20-Amp 20/208 V – .45/2.82 kW heat 42

RAK0 Universal Power Cord – 2800/800/5800 – 0-Amp 20/208 V – 5.0/4.09 kW heat 42

RAK4002A Direct Connect Junction Box – 20/208-volt units 2800/800 Series 42

RAK4002B Direct Connect Junction Box – 20/208-volt units 5800 Series 42

RAK4002CW Wiring Harness w/ Inline Connector - Adapt Line Cord to Direct Connection 4

RAK4157 208/20V Universal Power Supply, 15 Amp for 2800, 800, 5500, 5800, 7500 only 42

RAK4207 208/20V Universal Power Supply, 20 Amp for 2800, 800, 5500, 5800, 7500 only 42

RAK407 208/20V Universal Power Supply, 0 Amp for 2800, 800, 5500, 5800, 7500 only 42

RAK5157 265/275V Universal Power Supply, 15 Amp for 2800, 800, 5500, 5800, 7500 only 42

RAK5207 265/275V Universal Power Supply, 20 Amp for 2800, 800, 5500, 5800, 7500 only 42

RAK507 265/275V Universal Power Supply, 0 Amp for 2800, 800, 5800, 7500 only 42

RAK5172 Universal Connection Kit – 265V – 15 Amp – Use w/ RAK204E15 Sub-Base – 2.55 kW heat 42

RAK5202 Universal Connection Kit – 265V – 20 Amp – Use w/ RAK204E20 Sub-Base – .45 kW heat 42

RAK502 Universal Connection Kit – 265V – 0 Amp – Use w/ RAK204E0 Sub-Base – 5.0 kW heat 42

RAK601 Duct extension – Insulated – 44" long – includes Register and Mounting Flange 7

RAK602 Register and Trim Flange (Included with RAK601) 7

RAK6052 Duct Adapter for New Installation (or older non-GE Duct Adapter Installation) 7

RAK7012 Duct Transition for 2800/800 Replacing Existing Chassis (Original Installation Pre-1988) 7

RAK7022 Duct Transition for 2800/800 Replacing Existing Chassis (1988–1998 Original Installation) 7

RAK802 Locking Door Kit 11

RAK806 Control Panel Cover (for use with remote thermostat) 15

RAK901L Wall Case Insulation Kit 22

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 57/60

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 58/6058

General Installation Suggestions

Ducted Installation Comments

New Installations

The GE Zoneline® 2800 and 800 series are approved forducted installation using the GE Duct Adapter model RAK6052and the GE Duct Extension RAK601. A field-fabricated ductextension with the same interior measurements as the RAK601may be used with the RAK6052 duct adapter. GE does not

recommend ducting in more than one direction.

The use of a duct adapter other than the RAK6052 is notapproved by GE and may cause problems such as inadequateairflow to the secondary room or the unit shutting off on oneof the overload devices.

Failure to allow for adequate air return from the secondaryroom is often the cause of less than satisfactory performanceof a ducted installation.

Replacement Installations

GE offers duct adapters to allow for easy replacements of previous design chassis in ducted installations where a GE

duct adapter was used in the original installation. A ductadapter is available that will align with the duct extensionwhen GE-built components were used in the original installation.

The duct extension used from the early 1960s until late 1987was 8-/8" high by 6-1/2" wide. If the chassis to be replaced isthe flat-top discharge (design until late 1987) the duct adaptermodel RAK7012 will align with the existing duct extension.This means the duct extension will not have to be changed.However, to keep the cost of the replacement to a minimumthere are components that will need to be taken off theexisting installation and used on the RAK7012 duct adapter.The wall case mounting brackets, screws, discharge grille,damper, and end cap will need to be retained.

If the chassis is a slope-front discharge and the ductdimensions are 8-/8" high by 6-1/2" wide then thechassis has already been replaced and the purchaseof a new duct adapter is not required. The only piece thatneeds to be replaced in this installation is the transitionpiece, model RAK7022, which fits between the chassis andthe duct adapter.

If the chassis being replaced has a model number thatbegins with AZ22E, AZ22, AZ25, AZ2, AZ2H or AZ5, thenew 2800 or 800 Series unit can be installed using the samecomponents that were used for the 2200 or 200 Series unit.

If the existing chassis is a slope-front discharge and the ductdimensions are 7-/2" high by 6-1/2" wide only the RAK7022transition piece is required to install a 2800 or 800 Seriesunit in the ducted installation.

There were a number of Zoneline units installed in ductedinstallations that did not use a GE duct adapter. The easiestway to determine if the existing duct adapter is a GE ductadapter is to compare the duct adapter dimensions to the

dimensions above. If the dimensions are different than thedimensions above or it the duct adapter is not made of sheetmetal, it is not a GE duct adapter. In such installations GErecommends the removal of the old duct adapter and ductextension and the installation of a RAK6052 duct adapterand a RAK601 duct extension. Zoneline units installed ininstallations not using GE duct adapters and an extensionwith the same cross-section dimensions as the duct adaptermay not be covered by the warranty.

What is coveredLimited one-year warrantyFor one year from date of original purchase, we will provide, free of charge, parts and service labor on-site to repair or replace any partof the Zoneline that fails because of a manufacturing defect.

Limited five-year warranty

For five years from the date of original purchase, we will provide, free of charge, parts and on-site service labor to repair or replace any part of the sealed refrigerating system (the compressor, condenser, evaporatorand all connecting tubing) that fails because of a manufacturing defect.

Limited 2nd through 5th year parts warranty

For the second through the fifth year from date of original purchase,GE will provide, free of charge, parts that fail as a result of a manufactur-ing defect. Parts covered are fan motors, switches,thermostat, heater, heater protectors, compressor overload, solenoids,circuit boards, auxiliary controls, thermistors, frost controls, icr pump,capacitors, varistors, and indoor blower bearing. This is a limited

parts-only warranty, and does not include labor or transportationto and from the service shop.

All warranty service will be provided by our factory service centers or byour authorized customer care® servicers during normal working hours.

*See written warranty for details

Zoneline warranty*

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 59/60

Alphabetical Index

Categor Page No.

Accessor List 56

Application Comments 20

Auxiliar Control Switches 12-13

Case Dimensions 21

Central Desk Control 14

Condensate Disposal Sstems 34-36

Cooling/Heat Pump Performance Data 45

Ducted Installations 37-39

Dr Air 4

Electrical Connection 42

Essential Elements Ordering Overview 43

Exterior Grilles 40-41

Features and Benefits 9-11

Features Table 8

General Installation Suggestions 57-58Heat Pumps and Energ Savings 18-19

Introduction to Zoneline® 6

Latent Sstem Capacit 46

Maximum Connected Load 44

Mini Specs 2800 2

Mini Specs 3800 2

Mini Specs 5800 2

Mini Specs Power Connection Kits and Nomenclature 3

Normal yearl Operating Data 47

Remote Thermostat Control 15-17

Schematics 48-50

Specifications 55

Suggested Big Form Specifications 51-53

Table of Contents 5

Wall Case/Sub Base Installation 22-33

Warrant 58

Zoneline Sstem 7

5

ge.com

Exterior Grille Color Samples

Bittersweet Chocolate

Maple

Warm Gra Beige

Colors ma var slightl due to printing process.

8/3/2019 800 Series Data Manual

http://slidepdf.com/reader/full/800-series-data-manual 60/60

A centur of qualit and innovationFor more than a centur, GE has been committed to producing innovative productsthat change the wa people live. The result of thorough research and rigorous testing,GE appliances are designed for ears of dependable performance.Toda, the GE tradition of qualit and innovation continues.