+ All Categories
Home > Documents > 8100 Mobile Device Test System - Spirent · 8100 Mobile Device Test System Data Retry ......

8100 Mobile Device Test System - Spirent · 8100 Mobile Device Test System Data Retry ......

Date post: 30-Apr-2018
Category:
Upload: vonhi
View: 252 times
Download: 2 times
Share this document with a friend
42
8100 Mobile Device Test System Data Retry - LTE User Manual
Transcript

8100 Mobile Device Test System Data Retry - LTE

User Manual

Spirent 541 Industrial Way West Eatontown, NJ 07724 USA

Email: [email protected] Web: http://www.spirent.com

AMERICAS 1-800-SPIRENT • +1-818-676-2683 • [email protected] EUROPE AND THE MIDDLE EAST +44 (0) 1293 767979 • [email protected] ASIA AND THE PACIFIC +86-10-8518-2539 • [email protected]

This manual applies to Data Retry - LTE Test Packs Version 1.3 or higher.

Page Part Number: 71-006376, Version A3

Copyright © 2011 Spirent. All Rights Reserved.

All of the company names and/or brand names and/or product names referred to in this document, in particular, the name “Spirent” and its logo device, are either registered trademarks or trademarks of Spirent plc and its subsidiaries, pending registration in accordance with relevant national laws. All other registered trademarks or trademarks are the property of their respective owners.

The information contained in this document is subject to change without notice and does not represent a commitment on the part of Spirent. The information in this document is believed to be accurate and reliable; however, Spirent assumes no responsibility or liability for any errors or inaccuracies that may appear in the document.

Table of Contents

1. Introduction .......................................................................................... 3

1.1. Overview ........................................................................................... 3

1.2. Intended Audience ............................................................................. 3

1.3. Before You Get Started ....................................................................... 3

1.4. Security Information .......................................................................... 3

1.5. Accessing Documentation .................................................................. 5

1.5.1. Accessing Documentation from Windows Explorer ................................... 5

1.5.2. Accessing Documentation from Test Manager ......................................... 6

2. Data Retry - LTE Description .................................................................. 7

2.1. Overview ........................................................................................... 7

2.2. Description ........................................................................................ 7

3. Using the Data Retry - LTE Test Packs .................................................... 8

3.1. Overview ........................................................................................... 8

3.2. Configuring the Platform Parameters .................................................. 8

3.2.1. Supported Platforms ............................................................................... 8

3.2.2. 8100-B Series Platform Parameters ........................................................ 8

3.3. Configuring the UE Parameters ........................................................... 9

3.3.1. UE Interface Parameters .......................................................................... 9

3.3.2. UE Manual Interface Parameters ........................................................... 10

3.3.3. UE AT Interface Parameters .................................................................... 11

3.3.4. UE Capability Parameters ...................................................................... 13

3.4. Configuring the Session Parameters ................................................. 14

3.5. Selecting the Parameter Files for Session Execution .......................... 15

3.6. Locating the Test Suites and Test Cases ............................................ 16

3.6.1. Locating Pre-defined Module Test Suites ............................................... 16

3.6.2. Locating Module Test Cases ................................................................... 17

3.7. Creating a Custom Test Suite ............................................................ 18

3.8. Configuring Test Case Parameters .................................................... 20

3.9. Running a Test Suite ........................................................................ 21

ii | 8100: Data Retry-LTE User Manual

4. Test Reference .................................................................................... 23

4.1. Overview ......................................................................................... 23

4.2. Test Suite Execution ......................................................................... 23

4.3. Data Retry - LTE Test Cases ............................................................... 24

4.3.1. 3GPP TS 36.331 RRC Scenarios .............................................................. 24

4.3.2. 3GPP TS 24.301 EMM Common Procedures ........................................... 26

4.3.3. 3GPP TS 24.301 EMM Specific Procedures ............................................. 28

4.3.4. 3GPP TS 24.301 EMM Connection Management Procedures .................. 30

4.3.5. 3GPP TS 24.301 EPS Session Management Scenarios ........................... 32

4.3.6. 3GPP TS 24.301 Network Initiated ESM Procedures ............................... 34

4.4. Description of Data Retry - LTE Module Test Parameters ..................... 36

4.4.1. General ................................................................................................ 36

4.4.2. Network Configuration .......................................................................... 36

4.4.3. Data Retry Options ............................................................................... 38

4.4.4. Test Criteria .......................................................................................... 40

1. Introduction

1.1. Overview

This document provides information on the Data Retry - LTE Test Packs. You will become familiar with the Test Pack Suites, Test Cases, and setting up LTE testing scenarios in the Test Manager environment by following the step-by-step procedures and Test Reference documentation.

1.2. Intended Audience

This manual is intended for those who have a working knowledge of wireless communication equipment, and are familiar with the automated testing of mobile devices. It is assumed that the audience is familiar with the Test Manager GUI environment. Those who are unfamiliar with the Test Manager should refer to the Test Manager User Manual before proceeding further.

1.3. Before You Get Started

Before getting started with this guide, install all software and power up the test system. The controller PC is shipped with the Test Manager Test Executive software and Data Retry - LTE Test Packs installed.

1.4. Security Information

The Data Retry - LTE Test Packs are shipped with the appropriate dongle and software/hardware security passwords configured.

To verify the security information:

1. Open Test Manager and select Help>About. The About Test Manager window displays, as shown in Figure 1-1.

4 | 8100: Data Retry-LTE User Manual

Figure 1-1: About Test Manager Window

2. Select the Passwords tab.

3. Under Installed Features, confirm the Data Retry - LTE Test Packs are installed, as shown in Figure 1-2.

Figure 1-2: About Test Manager Window – Installed Features

Password authentication is a pre-requisite to running any tests supported by these Test Packs. This password is tied to security information provided by the USB hard-lock dongle that comes with the module installation.

If you have any questions or concerns, contact Spirent Technical Support at support.spirent.com, or by phone at 1-800-SPIRENT.

Chapter One: Introduction | 5

1.5. Accessing Documentation

There are two ways to access this document from the Controller PC:

1. Windows Explorer

2. Test Manager

1.5.1. Accessing Documentation from Windows Explorer

Access this Manual offline by navigating to C:\Program Files\Spirent Communications\Test Manager\Modules\Data Retry - LTE\User Manual.pdf” using Windows Explorer, as shown in Figure 1-3.

Figure 1-3: Accessing the Manual from Windows Explorer

6 | 8100: Data Retry-LTE User Manual

1.5.2. Accessing Documentation from Test Manager

Access this Manual from the Test Manager menu by selecting: Help>Modules>Data Retry - LTE>User Manual.pdf, as shown in Figure 1-4.

Figure 1-4: Accessing the Manual from Test Manager

2. Data Retry - LTE Description

2.1. Overview

This chapter provides a high-level overview of the key software and hardware components necessary to configure and use the Data Retry - LTE Test Packs.

2.2. Description

The Data Retry - LTE Module is an integrated software component that allows you to perform interactive and automated testing of Data Retry scenarios on a UE device. Support is provided for:

• LTE Bands: 1, 2, 4, 5, 7, 10, 12, 13, 14, 17, 20, 24, 25, and 26.

The Data Retry - LTE module test cases run with the Test Manager software. This provides an easy way to automate test sessions with analysis and reporting capabilities.

3. Using the Data Retry - LTE Test Packs

3.1. Overview

This chapter gives information on using Data Retry - LTE from Test Manager.

This includes the following steps:

1. Configuring the Platform Parameters

2. Configuring the UE Parameters

3. Configuring the Session Parameters

4. Selecting the Parameter Files for Session Execution

5. Locating the Test Cases

6. Creating a Custom Test Suite

7. Configuring Test Case parameters

8. Running a Test Suite

3.2. Configuring the Platform Parameters

3.2.1. Supported Platforms

The Data Retry - LTE Test Packs support the following platforms:

• 8100-B Series

3.2.2. 8100-B Series Platform Parameters

The parameters for the 8100-B Series platform configure the technologies that are present in the system, as shown in Figure 3-1. Set the E2010S Enabled parameter to True to support LTE. The SR8078 Enabled parameter can be set as either True or False; depending if TCU is integrated in the Data Retry - LTE system.

NOTE: The platform parameters are correctly configured when the system is delivered. It should not be necessary to modify them.

Chapter Three: Using the Data Retry-LTE Test Packs | 9

Figure 3-1: 8100-B Series Platform Parameters

3.3. Configuring the UE Parameters

The level of automation and reliability of the system is heavily dependent on the ability of the system to control the UE. UE parameters are configured to facilitate these activities.

3.3.1. UE Interface Parameters

The UE interface parameters specify how the UE is controlled during test case execution. The options for the UE Control Method are:

• Manual: The system prompts the operator to perform actions on the UE.

• AT: The system issues the specified AT commands to control the UE.

• Custom: (Advanced) Allows custom UE control. If Custom is selected, the UE Control Sequence File parameter specifies the Control Sequence file used by the system.

The ability of the system to return the UE to a known state before execution of a test case is important. If the UE supports a reliable reset command, set the Reset for Ensure Idle parameter to True.

10 | 8100: Data Retry-LTE User Manual

Figure 3-2: UE Parameters Window – UE Interface Parameters

NOTE: In cases where the UE Control Method is set to anything other than “Manual”, the Manual method will be attempted as a fall-back if a command fails or is not provided.

3.3.2. UE Manual Interface Parameters

If the UE Control Method parameter of the UE Interface tab is set to “Manual”, if a command fails, or is not provided by the selected UE Control Method, the UE Manual Interface parameters are used. In this case, a window displays prompting you to perform the necessary action on the UE.

• Timeout Parameters: Specifies how long the system waits before automatically selecting the defined Timeout Button. The timeout value is selected from a drop-down box providing a range from "Disabled" to "Indefinite." A value of "Disabled" indicates no user prompt will be displayed and testing will proceed as if the UE control was completed successfully. A value of “Indefinite” indicates the function will wait indefinitely. Note that even if Manual control is not selected, it may be used in case of failure. If the timeout value is set to “Indefinite”, the system will wait indefinitely, which may not be desirable.

• Timeout Button Parameters: If a timeout other than "Disabled" or "Indefinite" is specified, these parameters specify if the OK or Cancel button is selected when the timeout expires.

Chapter Three: Using the Data Retry-LTE Test Packs | 11

Figure 3-3: UE Parameters Window – UE Manual Interface Parameters

Configuring these parameters correctly can be effective in allowing some level of automation; even if AT commands are not available or supported for the UE under Test.

For example, if the UE can be configured to auto-answer an incoming call, you can set the timeout for Answer Voice Call. This allows the UE time to auto-answer the call, and the Timeout Button for Answer Voice Call can be set to OK. This configuration allows the device to reliably answer network-initiated voice calls.

3.3.3. UE AT Interface Parameters

If the UE reliably supports AT commands, AT control can be very useful. The UE is connected to the Data Client PC for AT control after the manufacturer's driver software is installed.

The following parameters are provided:

• Client IP Address: Set this parameter to the IP address of the Data Client PC. NOTE: The default address 192.168.0.61 should not be changed.

• Primary COM Port Settings/Secondary COM Port Settings: These parameters configure the standard serial port parameters. Two COM ports can be used for different commands. NOTE: The Data Retry - LTE Module only makes use of the Primary COM Port.

Port: Set this parameter to the port on the Data Client PC assigned to the modem when the UE is connected.

Bits per Second: Configure the baud rate.

Data Bits: Configure the number of data bits.

Parity: Configure the parity.

12 | 8100: Data Retry-LTE User Manual

Stop Bits: Configure the stop bits.

Flow Control: Configure the flow control.

Enable DTR: Enables Data Terminal Ready Signaling.

Enable RTS: Enables Request To Send Signaling.

New Line: Specifies the new line terminator to use.

• Commands: Configure the available AT command strings.

• Test AT Commands: Use this wizard to test AT commands to check if the UE responds correctly and reliably before testing.

Figure 3-4: UE Parameters Window – UE AT Interface Parameters

Chapter Three: Using the Data Retry-LTE Test Packs | 13

3.3.4. UE Capability Parameters

UE Capability parameters configure the security and authentication settings for the UE as shown in Figure 3-5. These parameters also include configuring the PDN number and properties, as shown in Figure 3-6.

The following parameters are provided for security and authentication settings:

• AS Security: AS Security settings

• NAS Security: NAS Security settings

• NAS Authentication: NAS Authentication settings

• HSS Settings: HSS Settings

Figure 3-5: UE Parameters Window –Security and Authentication Parameters

The following parameters are provided for configuring PDN number and PDN properties:

• PDNs: Parameters for supported PDNs.

• PDN [N]: Specifies valid PDN settings.

• IP Address Type: Specifies the type of IP address the UE will request. Valid Values: IPv4, IPv6, IPv4v6.

• APN: Specifies the Access Point Name (APN) the UE will communicate with.

• Services: Parameters for mapping services to PDNs.

• Service [N]: Parameters for mapping the service to the PDN.

• Service: Specifies the service. Valid Values: Administrative, Application, IMS, and Internet.

• PDN: Specifies the PDN that carries this service.

14 | 8100: Data Retry-LTE User Manual

Figure 3-6: UE Parameters Window – UE Capability Parameters for PDN

NOTE: There is great variability in the AT commands supported by UE vendors and how reliably they work. Experimentation may be necessary to determine the best settings.

3.4. Configuring the Session Parameters

Session Parameters control the execution of the session, as shown in Figure 3-7.

• Re-running Test Cases: These parameters control the automatic re-running of test cases that end with a final result of “Incomplete” or “Failed”.

• Re-running Test Case Iterations: These parameters control the behavior of iteration-based test cases.

NOTE: Because Data Retry – LTE test cases are not iteration-based; these parameters are not used.

• Reset UE between Test Cases: Resetting the UE between test cases can improve system performance and stability in some cases.

NOTE: The Data Retry – LTE test cases automatically reset the UE at various points during the test; it is not necessary to set this parameter to “True”.

Chapter Three: Using the Data Retry-LTE Test Packs | 15

Figure 3-7: Session Control Parameters Window

3.5. Selecting the Parameter Files for Session Execution

As indicated in the Test Manager User Manual, you cannot run a suite successfully unless it undergoes validation using the specified Platform, Session and UE Parameter files.

In the Execute Session window, select the Session File, the UE File, and the Platform File. After the Platform File is selected, select the Platform as shown in Figure 3-8.

16 | 8100: Data Retry-LTE User Manual

Figure 3-8: Selecting Parameter Files for Data Retry - LTE Module

3.6. Locating the Test Suites and Test Cases

3.6.1. Locating Pre-defined Module Test Suites

1. In the Test Manager, select the Suite Files tab in the File Cabinet and open the Suite Files folder tree.

2. Open the Data Retry - LTE folder tree. All of the pre-defined Suites available for Data Retry Testing display, as shown in Figure 3-9.

Chapter Three: Using the Data Retry-LTE Test Packs | 17

Figure 3-9: Locating Data Retry - LTE Module Pre-defined Suites

3.6.2. Locating Module Test Cases

1. In Test Manager, under the Modules tab, open the Modules folder.

2. Open the LTE-Data Retry sub-folder. This folder contains the Data Retry - LTE Test Cases, as shown in Figure 3-10.

Figure 3-10: Data Retry - LTE Module Test Cases

18 | 8100: Data Retry-LTE User Manual

3.7. Creating a Custom Test Suite

To set up a custom Data Retry - LTE test, you must create a Test Suite.

To create a Test Suite:

1. In Test Manager, select File>New>Suite File, as shown in Figure 3-11.

Figure 3-11: Creating a New Suite

2. You can also use the toolbar shortcuts available to create a new file, as shown in Figure 3-12.

Figure 3-12: Creating a Suite File using the Toolbar Shortcut

3. A new Test Suite window opens with a default file name. This window allows you to sequence and arrange the tests.

4. To add a test from the Data Retry - LTE Module, drag the desired test from the Module Files tab of the File Cabinet on the left and move it over to the Suite File on the right, as shown in Figure 3-13 and Figure 3-14.

Chapter Three: Using the Data Retry-LTE Test Packs | 19

Figure 3-13: Transferring a Test Case into a Suite

Figure 3-14: Successfully Transferred Test Case

5. Configure the parameters for each Test Case based on your testing needs. Refer to Section 3.6 on page 19 and Chapter 4 on page 22 for additional information on configuring Test Case Parameters.

6. When you have completed adding and sequencing the test cases, save the Suite file. The custom suite file displays in the File Cabinet, as shown in Figure 3-15.

Figure 3-15: Customized Suite Saved to the File Cabinet

20 | 8100: Data Retry-LTE User Manual

3.8. Configuring Test Case Parameters

1. In Test Manager, select the desired Test Suite from the Parameters tab in the File Cabinet.

2. In the Suite Editor, select the Test Case, as shown in Figure 3-16.

Figure 3-16: Configuring Test Case Parameters

3. Select the appropriate defining parameters for the test. For more information on setting parameters, refer to Chapter 4 on page 22.

4. Save changes to the Suite File.

Chapter Three: Using the Data Retry-LTE Test Packs | 21

3.9. Running a Test Suite

After creating the custom Data Retry - LTE test suite and configuring the test case parameters (refer to Section 3.6 on page 19 for details), or selecting a pre-defined test suite, you must ensure the suite passes validation.

As discussed in the Test Manager User Manual, the key requirements to run a user-defined suite are a valid Session, UE, and Platform file.

To run the test suite:

1. In the Test Manager, open the desired test suite from the Suite Files tab of the File cabinet, as shown in Figure 3-17.

Figure 3-17: Loading a Data Retry - LTE Test Suite

NOTE: Each Test Case in a pre-defined Suite has test case parameters configured to support the test definition. You do not have to alter them unless you are writing your own test suite. For more information on configuring test case parameters, refer to Section 3.6 on page 19 and Chapter 4: Test Reference on page 22.

2. In the Test Manager menu, select Execute>Start Session>Run All Test Cases to start executing the entire Test Suite. You also have the option of executing only the currently selected test case. The Execute Session window displays.

3. Select the appropriate parameter files and platform. For more information on selecting these files, refer to Chapter 4 on page 23.

22 | 8100: Data Retry-LTE User Manual

4. If desired, specify the Tester Name, UE Manufacturer, and UE Model. These fields display on all reports you create based on the results of this session.

NOTE: The Results folder and Platform File selections are already set, it is not necessary to make changes to these fields.

5. Click OK to begin validation. If successful, the test session begins, as shown in Figure 3-18.

Figure 3-18: Test Session in Progress

4. Test Reference

4.1. Overview

This chapter describes the Data Retry - LTE Module test cases in greater detail, including the algorithms implemented during test execution.

The information is grouped into the following subsections:

1. Test Suite Execution

2. Data Retry - LTE Test Cases

3. Description of Data Retry - LTE Module Test Parameters

4.2. Test Suite Execution

This section describes the sequence of operations performed during the execution of a Test Suite from the Test Manager.

Validate Suite

Start Session

Connect to the Instruments

End Session

Success

Execute Tests

Disconnect from Instruments

Failure

Failure

Success

Figure 4-1: Test Suite Execution Flowchart

24 | 8100: Data Retry-LTE User Manual

4.3. Data Retry - LTE Test Cases

There are six types of test cases supported by the Data Retry - LTE Test Packs. This section describes the test cases that facilitate the Testing functionality of the Data Retry - LTE Test Packs.

1. 3GPP TS 24.301 EMM Common Procedurest

2. 3GPP TS 24.301 EMM Connection Management Procedures

3. 3GPP TS 24.301 EMM Specific Procedures

4. 3GPP TS 24.301 EPS Session Management Scenarios

5. 3GPP TS 24.301 Network Initiated ESM Procedures

6. 3GPP TS 36.331 RRC Scenarios

4.3.1. 3GPP TS 36.331 RRC Scenarios

4.3.1.1 Description

This test case is designed to verify the behavior of the UE when the RRCConnectionReject message is received during the initial attempt of the UE to attach to the LTE network.

4.3.1.2 Required Test Equipment

This test requires the following equipment:

• LTE network emulators; depending on the technologies specified in the configured scenarios.

Chapter Four: Data Retry-LTE Test Cases | 25

4.3.1.3 Test Parameters

The following test parameters are supported for this test.

Test Parameters

General • Description • Procedure Pathname

Network Configuration • Configuration File Path • PDN Gateway

o PDNs o PDN[1] o APN o IP Address Type o Default Bearer QCI o Enable Dedicated Bearers o Dedicated Bearers o Dedicated Bearer o QCI

• eNodeB 1 • Operating Band • Downlink Channel Number • Downlink Bandwidth • MCC • MNC • Tracking Area Code • Cell Identity • RSTP

Data Retry Options • Retry Type • Retry Scenarios • RRC Scenarios • RRC Connection Reject Type • RRC Connection Reject Wait Timer • Retry Monitor Timer

Test Criteria • Acceptable Early Arrival Limit • Acceptable Late Arrival Limit • Expected Retry Interval • Early Termination Enabled • IMS Required

4.3.1.4 Test Results

The following results are generated for this test:

• Pass/Fail

26 | 8100: Data Retry-LTE User Manual

4.3.1.5 Pass / Fail Criteria

Testing Scenario Test Result

The test completes having performing each UE requirement as specified within the time specified.

Pass

The test completes without performing each UE requirement as specified within the time specified.

Fail

The test cannot complete due to UE/Network Failures or an unknown failure.

Incomplete (Other)

4.3.2. 3GPP TS 24.301 EMM Common Procedures

4.3.2.1 Description

This kind of test cases is designed to verify the UE’s behavior when the UE is unable to authenticate the network because of an invalid MAC code in the NAS Authentication Request message.

4.3.2.2 Required Test Equipment

This test requires the following equipment:

• LTE network emulators depending on the technologies specified in the configured scenarios.

4.3.2.3 Test Parameters

The following test parameters are supported for this test.

Test Parameters

General • Description • Procedure Path name

Chapter Four: Data Retry-LTE Test Cases | 27

Test Parameters

Network Configuration • Configuration File Path • PDN Gateway

o PDNs o PDN[1] o APN o IP Address Type o Default Bearer QCI o Enable Dedicated Bearers o Dedicated Bearers o Dedicated Bearer o QCI

• eNodeB 1 • Operating Band • Downlink Channel Number • Downlink Bandwidth • MCC • MNC • Tracking Area Code • Cell Identity • RSTP

Data Retry Options • Retry Type • Retry Scenarios • EMM Common Scenarios • UE Authentication Failure Type • Retry Monitor Timer • Initial Attachment Timer • Internet PDN Timer • Reconfiguration Timer

Test Criteria • Acceptable Early Arrival Limit • Acceptable Late Arrival Limit • Expected Retry Interval • Early Termination Enabled • IMS Required

4.3.2.4 Test Results

The following results are generated for this test:

• Pass/Fail

28 | 8100: Data Retry-LTE User Manual

4.3.2.5 Pass / Fail Criteria

Testing Scenario Test Result

The test completes having performing each UE requirement as specified within the time specified.

Pass

The test completes without performing each UE requirement as specified within the time specified.

Fail

The test cannot complete due to UE/Network Failures or an unknown failure.

Incomplete (Other)

4.3.3. 3GPP TS 24.301 EMM Specific Procedures

4.3.3.1 Description

This kind of test cases is designed to verify the UE’s behavior when the UE receives a NAS Attach Reject message while attempting to attach to the LTE network.

4.3.3.2 Required Test Equipment

This test requires the following equipment:

• LTE network emulators depending on the technologies specified in the configured scenarios.

4.3.3.3 Test Parameters

The following test parameters are supported for this test.

Test Parameters

General • Description • Procedure Pathname

Chapter Four: Data Retry-LTE Test Cases | 29

Test Parameters

Network Configuration • Configuration File Path • PDN Gateway

o PDNs o PDN[1] o APN o IP Address Type o Default Bearer QCI o Enable Dedicated Bearers o Dedicated Bearers o Dedicated Bearer o QCI

• eNodeB 1 • Operating Band • Downlink Channel Number • Downlink Bandwidth • MCC • MNC • Tracking Area Code • Cell Identity • RSTP

Data Retry Options • Retry Type • Retry Scenarios • EMM Specific Scenarios • EMM Cause Code • Retry Monitor Timer • Initial Attachment Timer • Internet PDN Timer • Reconfiguration Timer

Test Criteria • Expected Retry Interval • Early Termination Enabled • IMS Required

4.3.3.4 Test Results

The following results are generated for this test:

• Pass/Fail

4.3.3.5 Pass / Fail Criteria

Testing Scenario Test Result

The test completes having performing each UE requirement as specified within the time specified.

Pass

30 | 8100: Data Retry-LTE User Manual

Testing Scenario Test Result

The test completes without performing each UE requirement as specified within the time specified.

Fail

The test cannot complete due to UE/Network Failures or an unknown failure.

Incomplete (Other)

4.3.4. 3GPP TS 24.301 EMM Connection Management Procedures

4.3.4.1 Description

This kind of test cases is designed to verify the behavior of the UE when it receives a NAS Service Reject message while attempting to re-connect to the LTE network.

4.3.4.2 Required Test Equipment

This test requires the following equipment:

• LTE network emulators depending on the technologies specified in the configured scenarios.

4.3.4.3 Test Parameters

The following test parameters are supported for this test.

Test Parameters

General • Description • Procedure Pathname

Chapter Four: Data Retry-LTE Test Cases | 31

Test Parameters

Network Configuration • Configuration File Path • PDN Gateway

o PDNs o PDN[1] o APN o IP Address Type o Default Bearer QCI o Enable Dedicated Bearers o Dedicated Bearers o Dedicated Bearer o QCI

• eNodeB 1 • Operating Band • Downlink Channel Number • Downlink Bandwidth • MCC • MNC • Tracking Area Code • Cell Identity

o RSTP

Data Retry Options • Retry Type • Retry Scenarios • EMM Connection Management Scenarios • EMM Cause Code • Retry Monitor Timer • Initial Attachment Timer • Internet PDN Timer • Reconfiguration Timer

Test Criteria • Expected Retry Interval • Early Termination Enabled • IMS Required

4.3.4.4 Test Results

The following results are generated for this test:

• Pass/Fail

32 | 8100: Data Retry-LTE User Manual

4.3.4.5 Pass / Fail Criteria

Testing Scenario Test Result

The test completes having performing each UE requirement as specified within the time specified.

Pass

The test completes without performing each UE requirement as specified within the time specified.

Fail

The test cannot complete due to UE/Network Failures or an unknown failure.

Incomplete (Other)

4.3.5. 3GPP TS 24.301 EPS Session Management Scenarios

4.3.5.1 Description

This kind of test cases is designed to verify the UE’s behavior when the network fails to assign an IPv6 address to the UE.

4.3.5.2 Required Test Equipment

This test requires the following equipment:

• LTE network emulators depending on the technologies specified in the configured scenarios.

4.3.5.3 Test Parameters

The following test parameters are supported for this test.

Test Parameters

General • Description • Procedure Pathname

Chapter Four: Data Retry-LTE Test Cases | 33

Test Parameters

Network Configuration • Configuration File Path • PDN Gateway

o PDNs o PDN[1] o APN o IP Address Type o Default Bearer QCI o Enable Dedicated Bearers o Dedicated Bearers o Dedicated Bearer o QCI

• eNodeB 1 • Operating Band • Downlink Channel Number • Downlink Bandwidth • MCC • MNC • Tracking Area Code • Cell Identity

o RSTP

Data Retry Options • Retry Type • Retry Scenarios • EPS Session Management Scenarios • ESM Cause Code • Max Router Solicitation • Router Solicitation Interval • Initial Attachment Timer

Test Criteria • Acceptable Early Arrival Limit • Acceptable Late Arrival Limit • Expected Number of Retries • Early Termination Enabled • IMS Required

4.3.5.4 Test Results

The following results are generated for this test:

• Pass/Fail

4.3.5.5 Pass / Fail Criteria

Testing Scenario Test Result

The test completes having performing each UE requirement as specified within the time specified.

Pass

34 | 8100: Data Retry-LTE User Manual

The test completes without performing each UE requirement as specified within the time specified.

Fail

The test cannot complete due to UE/Network Failures or an unknown failure.

Incomplete (Other)

4.3.6. 3GPP TS 24.301 Network Initiated ESM Procedures

4.3.6.1 Description

This test case is designed to verify the behavior of the UE when the network fails to set up an EPS bearer or if the EPS bearer is deactivated.

4.3.6.2 Required Test Equipment

This test requires the following equipment:

• LTE network emulators depending on the technologies specified in the configured scenarios.

4.3.6.3 Test Parameters

The following test parameters are supported for this test.

Test Parameters

General • Description • Procedure Pathname

Chapter Four: Data Retry-LTE Test Cases | 35

Test Parameters

Network Configuration • Configuration File Path • PDN Gateway

o PDNs o PDN[1] o APN o IP Address Type o Default Bearer QCI o Enable Dedicated Bearers o Dedicated Bearers o Dedicated Bearer o QCI

• eNodeB 1 • Operating Band • Downlink Channel Number • Downlink Bandwidth • MCC • MNC • Tracking Area Code • Cell Identity • RSTP

Data Retry Options • Retry Type • Retry Scenarios • Network Initiated ESM Scenarios • ESM Cause Code • Retry Monitor Timer • Initial Attachment Timer

Test Criteria • Expected Number of Retries • Early Termination Enabled • IMS Required

4.3.6.4 Test Results

The following results are generated for this test:

• Pass/Fail

36 | 8100: Data Retry-LTE User Manual

4.3.6.5 Pass / Fail Criteria

Testing Scenario Test Result

The test completes having performing each UE requirement as specified within the time specified.

Pass

The test completes without performing each UE requirement as specified within the time specified.

Fail

The test cannot complete due to UE/Network Failures or an unknown failure.

Incomplete (Other)

4.4. Description of Data Retry - LTE Module Test Parameters

Most testing tasks can be accomplished using the defined User Test Suites. For individual testing needs, you can create custom Test Suites using the Module Test Cases and user-defined parameters.

You can change the following Test Parameters to define your testing needs:

• Network Configuration

• Test Options

• Test Criteria

These parameters are described in detail in the following sections.

4.4.1. General

Parameter

Description Specifies a short description for the test case.

Procedure Pathname Specifies a procedure pane file to be loaded. NOTE: A file browser is available to select the desired file.

4.4.2. Network Configuration

Parameter

Configuration File Path Specifies the eAirAccess Configuration File to be loaded. NOTE: A file browser is available to select the desired file.

Chapter Four: Data Retry-LTE Test Cases | 37

Parameter

• PDN Gateway>PDNs>PDN[] Sets the parameters for a PDN

• PDN Gateway>PDNs>PDN[]>APN Specifies the APN of the PDN to configure. Valid Values: Refer to the UE Capabilities section.

• PDN Gateway>PDNs>PDN[]>IP Address Type Specifies the type of PDN to configure. Valid Values: Match UE Setting, IPv4, IPv6, IPv4v6.

• PDN Gateway>PDNs>PDN[]>Default Bearer QCI Specifies QCI for the default bearer. Valid Range: 1 to 9.

• PDN Gateway>PDNs>PDN[]>Dedicated Bearers Enabled Enables or disables the use of dedicated bearers.

• PDN Gateway>PDNs>PDN[]>Dedicated Bearers Parameters for the dedicated bearers.

• PDN Gateway>PDNs>PDN[]>Dedicated Bearer>QCI Specifies QCI for the dedicated bearer. Valid Range: 1 to 9

eNodeB 1>Operating Band Sets the operating band Supported values: 1, 2, 4, 5, 7, 10, 12, 13, 14, 17, 20, 24, 25, 26

eNodeB 1>Operating Downlink Channel Number Sets the downlink channel number. Supported values: • Operating Band 1: 0 – 599 • Operating Band 2: 600 – 1199 • Operating Band 4: 1950 – 2399 • Operating Band 5: 2400 – 2649 • Operating Band 7: 2750 – 3449 • Operating Band 10: 4150 – 4749 • Operating Band 12: 5000 – 5179 • Operating Band 13: 5180 – 5279 • Operating Band 14: 5280 – 5379 • Operating Band 17: 5730 – 5849 • Operating Band 20: 6150 – 6449 • Operating Band 24: 7700 – 8039 • Operating Band 25: 8040 – 8689 • Operating Band 26: 8690 – 9039

eNodeB 1>Operating Downlink Bandwidth Sets the downlink bandwidth (MHz) Supported values: 1.4, 3, 5, 10, 15, 20

38 | 8100: Data Retry-LTE User Manual

4.4.3. Data Retry Options

Parameter

Retry Type Sets the retry behavior. Valid Values: • Positive Data Call - Verifies the UE can successfully make a successful data call • Time Based Retry - Verifies the UE doesn't retry after the initial failure or the UE retry pattern

matches the specified throttling interval • Number Limited Retry - Verifies the UE retry attempts matches the specified number of retries

Retry Scenarios Sets the retry failure methods scenarios. Valid Values: • RRC - Specifies RRC Retry Scenarios • EMM Common - Specifies EMM Common Retry Scenarios • EMM Specific - Specifies EMM Specific Retry Scenarios • EMM Connection Management - Specifies EMM Connection Management Retry Scenarios • EPS Session Management - Specifies EPS Session Management Retry Scenarios • Network Initiated ESM – Specifies Network-initiated ESM Scenarios

RRC Scenarios Sets the RRC failure methods. Valid Values: • RRC Connection Reject

RRC Connection Reject Type Sets the RRC Connection Reject Scenarios Valid Values: • Initial Attach - Network sends RRC Connection Reject during the initial attach • UE Initiated Traffic - Network sends RRC Connection Reject when UE sends data to a

connected PDN • Network Initiated Traffic - Network sends RRC Connection Reject when UE responds to a page

RRC Connection Reject Wait Timer Sets the wait timer in RRC Connection Reject Message (seconds)

EMM Common Scenarios Sets the EMM Common Procedures methods. UE Authentication Failure - UE responds with the NAS Authentication Failure Network Authentication Reject - Network responds with the NAS Authentication Reject UE Security Mode Reject - UE responds with a Security Mode Reject

UE Authentication Failure Type Sets the error fields in NAS Authentication Request message. Valid Values: • Invalid MAC Code • Invalid Separation Bit • Invalid SQN

Chapter Four: Data Retry-LTE Test Cases | 39

Parameter

Security Mode Reject Type Sets the scenario for UE to send a NAS Security Mode Reject message. Valid Values: • Initial Attach - UE is attempting an initial attach • UE-Initialed Service Request - UE is attempting to transition from EMM-Idle to EMM-

Connected state • PDN Connection Attempt - UE is attempting to connect to a PDN • PDN Disconnection Attempt - UE is attempting to disconnect from a PDN

EMM Specific Scenarios Sets the EMM Specific Procedures methods. Valid Values: • Network Attach Reject - UE receives a NAS Attach Reject message while attempting to attach • Attach Request Failure - UE's attach counter reaches the maximum value while attempting to

attach to the LTE network • Network Detach Request - UE receives a NAS Detach Request message from the network

EMM Cause Code Sets the EMM Cause Code. Valid Values: • "2 - IMSI unknown in HSS (0x02)" • "3 - Illegal UE (0x03)" • "6 - Illegal ME (0x06)" • "7 - EPS services not allowed (0x07)" • "8 - EPS services and non-EPS services not allowed (0x08)" • "9 - UE identity cannot be derived by the network (0x09)" • "10 - Implicitly detached (0x0A)" • "11 - PLMN not allowed (0x0B)" • "12 - Tracking Area not allowed (0x0C)" • "13 - Roaming not allowed in this tracking area (0x0D)" • "14 - EPS services not allowed in this PLMN (0x0E)" • "15 - No Suitable Cells In tracking area (0x0F)" • "19 - ESM failure (0x13)" • "Custom Code": User can input a valid EMM Cause Code defined in 3GPP 24.301 Table

9.9.3.9.1.

EMM Connection Management Scenarios Sets the EMM Connection Management Procedures Methods. Valid Values: • Network Service Reject - UE receives a NAS - Service Reject message while attempting to re-

connect to the LTE network

Network Initiated ESM Scenarios Set the Network Initiated ESM Scenarios Valid Values: • 2 PDN Connected when Deactivate EPS Bearer Context - UE receives deactivated EPS bearer

context request message from the network: 2 PDN connections open

40 | 8100: Data Retry-LTE User Manual

Parameter

EPS Session Management Scenarios Sets the EMM Cause Code defined in 3GPP 24.301 Table 9.9.3.9.1. Valid value (decimal): 2,3,5-26,39,40,95-101,111

Max Router Solicitation Sets the Max number of Router Solicitation messages.

Router Solicitation Interval Sets the timer between Router Solicitation messages (seconds).

ESM Cause Code Sets the ESM Cause Code. Valid Values: • "8 - Operator Determined Barring (0x08)" • "29 - User authentication failed (0x1D)" • "30 - Request rejected by Serving GW or PDN GW (0x1E)" • "31 - Request rejected, unspecified (0x1F)" • "32 - Service option not supported (0x20)" • "33 - Requested service option not subscribed (0x21)" • "34 - Service option temporarily out of order (0x22)" • "38 - Network failure (0x26)" • "Custom Code": User can input a valid EMM Cause Code defined in 3GPP 24.301 Table

9.9.4.4.1

Retry Monitor Timer Sets the monitor timer for retry attempts (in seconds).

4.4.4. Test Criteria

Parameter

Acceptable Early Arrival Limit Sets the tolerance limit for a retry attempt that may occur earlier than what is specified in the Expected Retry Interval (in seconds).

Acceptable Late Arrival Limit Sets the tolerance limit for a retry attempt that may occur later than what is specified in the Expected Retry Interval (in seconds).

Expected Retry Interval Defines the Throttling Interval (in seconds). Example: 0, 0, 10, 20, 30

Early Termination Enabled Enables or disables early termination of the test case. If enabled, test case terminates as soon as the final outcome can be determined.


Recommended