IONOS-NMS For FMX Training Handbook AET/TAC/ 8408 July 2011 issue
Transcript
  • IONOS-NMS For FMX

    Training Handbook

    AET/TAC/ 8408 July 2011 issue

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page ii IONOS-NMS for FMX Training handbook

    DISCLAIMER Documents supplied during the training sessions are not contractual. Descriptions, schematics, diagrams and figures are for illustration only and can be changed without notice. For contractual figures, please refer to official documentation.

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS Training handbook Page iii

    SUMMARY

    MODULE 1

    To be able to configure FMX for IONOS-NMS management

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page iv IONOS-NMS for FMX Training handbook

  • IONOS-NMS for FMX Training handbook Page 1-1

    IONOS-NMS for FMX

    Module 1.

    Goal : To be able to configure FMX for IONOS-NMS

    management

    MODULE 1. 1-1

    1.1. FMX MANAGEMENT 1-3 1.1.1. FRAME RELAY 1-5 1.1.2. GIE-P / GIE-S 1-10 1.2. SNMP 1-11 1.2.1. FMX HEADER WITH GIE-S 1-13 1.2.2. FMX HEADER WITH GIE-P 1-14 1.3. FMX NETWORK CONFIGURATION 1-18

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-2 IONOS-NMS for FMX Training handbook

    1.3.1. PARAMETERS OF CONFIGURATION 1-19 1.3.2. PROXY CONFIGURATION (GIE-P) 1-25 1.3.3. GIE-S CONFIGURATION 1-28 1.4. FMX NETWORK EXAMPLE 1-33 1.5. FMX NETWORK MANAGEMENT WITH IONOS-NMS 1-36 1.6. EXERCISE : NETWORK OF FMX 1-41 1.6.1. CORRECT VERSION 1-45 1.7. PROCESS 1-49 1.7.1. ATLANTIS CARD CONFIGURATION ON PC PROXY 1-49 1.7.2. CREATION OF A FMX (GIE-P HEADER) ON IONOS-NMS 1-51 1.7.3. GIE-S CARD CONFIGURATION IN HEADER MODE 1-52 1.7.4. GIE-S CARD CONFIGURATION IN NON-HEADER MODE 1-53

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-3

    1.1. FMX management Slide 2

    2| AET/TAC 8408 | July 2011

    IONOS-NMS : Operation and management

    The LCT provides all operation and monitoring functions of local or remote FMX :

    Set up of shelves, cards, synchronization parameters.

    Display of defaults, alarms and performances.

    Maintenance operations such as loopbacks and inventories.

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-4 IONOS-NMS for FMX Training handbook

    Slide 3

    3| AET/TAC 8408 | July 2011

    IONOS-NMS : Operation and management Its possible from a local FMX to manage a remote FMX. A FMX network is composed of FMX connected together via

    management channels ( DLCI):

    LCT(local)

    Network of FMX

    Local FMX

    Remote FMX

    Local connection :- Direct,

    - Via MODEM.

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-5

    1.1.1. Frame Relay Slide 4

    4| AET/TAC 8408 | July 2011

    IONOS-NMS : Frame Relay

    from 1 to 9FMX

    FMX

    from 1 to 8FMX

    Up to :64 FMX and/or SAGEM 2048.Only 50 FMX when using snmpLCT (IONOS-NMS).

    over a maximum of 10 levels.FMX

    FMX FMX

    FMX Header

    LCT

    * To reduce bandwidth consumption, management of the remote FMX is performedvia TS0 (7 directions) + 2 x 64kbps TS.

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-6 IONOS-NMS for FMX Training handbook

    Slide 5

    5| AET/TAC 8408 | July 2011

    Frame Relay (2Mb/s G704) : 8 Kbps (2 bits of the odd TS0s). 64 Kbps (any IT).

    P1/P2 : 64 Kbps V24/V11. Used to interconnect 2 Frame Relay FMX subnetworks .

    DLCI (Data Link Connection Identifier).

    IONOS-NMS : Frame Relay

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-7

    Slide 6

    6| AET/TAC 8408 | July 2011

    IONOS-NMS : Frame RelayFMX 2

    (Remote)

    GIE-S

    Frame relayFunction

    CARTE COB

    Orderwire

    Network of FMX

    FMX 1(Local)

    COBGIE-SLCT(local)

    Connection :

    - LOCAL- VIA MODEM

    COB A2S

    A2S

    Frame relayFunction Orderwire

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-8 IONOS-NMS for FMX Training handbook

    Slide 7

    7| AET/TAC 8408 | July 2011

    IONOS-NMS : Frame Relay

    G704orderwireFR

    GIE

    COB

    DLCI

    IP-IS

    O

    To the manager

    GIE

    LCT

    COB

    To an other FMX

    FMX1 FMX2

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-9

    Slide 8

    8| AET/TAC 8408 | July 2011

    FMX Header : Between IONOS-NMS and others FMX of the Frame Relay

    management network

    FMX none Header.

    IONOS-NMS : Management Network

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-10 IONOS-NMS for FMX Training handbook

    1.1.2. GIE-P / GIE-S Slide 9

    9| AET/TAC 8408 | July 2011

    The GIE card manages the communication between the FMX Header and IONOS-NMS :

    GIE-P (P4.3B/P4.3C) : None SNMP card. Use of a Proxy-FMX to translate the SNMP protocol in

    proprietary Sagem-FMX protocol.

    GIE-S (P4.4A) : SNMP card.

    IONOS-NMS : Management Network

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-11

    1.2. SNMP Slide 10

    10| AET/TAC 8408 | July 2011

    IP

    StructureManagementInformation

    describesManagementInformation

    Base

    Management station

    NEswith

    Embedded SNMP agents

    IONOS-NMS based on SNMP

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-12 IONOS-NMS for FMX Training handbook

    Slide 11

    11| AET/TAC 8408 | July 2011

    SNMP Protocol specifies the language used by agents and management stations to communicate.

    Protocol : type asynchronous question/answer. Connectionless. over UDP (User Datagram Protocol).

    SNMP system handles three kinds of requests :

    GET SET TRAP

    IP

    GET var

    GET ANSW

    var=5

    SET ANSW

    var

    SET var

    =3

    TRAPTRAP

    Simple Network Management Protocol (SNMP)

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-13

    1.2.1. FMX header with GIE-S Slide 12

    12| AET/TAC 8408 | July 2011

    1 GIE-S in each FMX Header, other version (GIE-P) possible in others FMX.

    IONOS-NMS : FMX Header with GIE-S

    IONOSNMS

    FMXGROUP

    (remote FMX)

    IP

    Ethernet

    FMXHeaderlocal

    GIE-

    S

    FMXGROUP

    (remote FMX)FMXHeaderlocal

    GIE-

    S

    J129 connector with RJ45 adaptation.

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-14 IONOS-NMS for FMX Training handbook

    1.2.2. FMX header with GIE-P

    Slide 13

    13| AET/TAC 8408 | July 2011

    PROXY

    IP

    GET

    TRAP iso-IP

    GET A

    NSW

    %&$*#(*!&$

    SET

    ))(@&^$

    @#@#^&89

    SET A

    NSW

    H&^9&

    *#$

    TRAP

    IONOS-NMS : FMX Header with GIE-P

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-15

    Slide 14

    14| AET/TAC 8408 | July 2011

    Management by IONOS-NMS using an external proxy. A proxy can manage 50 FMX. FMX Header : 1 for 20 FMX. The FMX Header has to be configured in mode Gateway. FMX none Headers part of the Group are configured none gateway.

    IONOSNMS

    FMX Group IP

    PROXY

    PROXY

    PC PROXY

    EthFMXHeader

    GIE-

    P

    X25

    J129

    IONOS-NMS : FMX Header with GIE-P

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-16 IONOS-NMS for FMX Training handbook

    Slide 15

    15| AET/TAC 8408 | July 2011

    PROXY

    X.25

    G704

    G704

    IONOS-NMS : Example physical presentation

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-17

    Slide 16

    16| AET/TAC 8408 | July 2011

    PROXY

    X.25

    DLCI 1

    DLCI 2

    DLCI 3

    DLCI 4

    IONOS-NMS : Example logical presentation

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-18 IONOS-NMS for FMX Training handbook

    1.3. FMX network configuration Slide 17

    17| AET/TAC 8408 | July 2011

    FMX network configuration :

    IONOS-NMS

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-19

    1.3.1. Parameters of configuration Slide 18

    18| AET/TAC 8408 | July 2011

    Parameters of configuration :

    FMX : An IP/ISO address for each FMX (6 bytes, decimal value < 256 separated by a .). An interface type for each FMX (with the neighbour FMX) : P1, P2 or Frame Relay. An identifier (DLCI) for each Frame Relay communication between two FMX

    IP/ISO Addresses : The setting of a frame relay network management for FMX equipment using the

    embedded channels of TS0 in the 2 Mbps links requires to take precautions with the IPiso adress on the FMX equipment as follows :

    In every FMX of a given frame relay management subnetwork, including the header FMX and those connected via PI/P2 interfaces, The first element of the IPiso address (Network ID) must be UNIQUE.

    If there is a mix of P4.4a (GIE-S) FMX equipment and P4.3c (GIE-P) in the subnetwork, the second element of the IPiso adress (Depth) must be ZERO.

    IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-20 IONOS-NMS for FMX Training handbook

    Slide 19

    19| AET/TAC 8408 | July 2011

    Parameters of configuration :

    FMX Header : FMX with GIE-P card :

    An IPv4 address for the Proxy used by the header. X25 parameters (address, clock, DCE/DTE) of the link with the Proxy.

    FMX with GIE-S card : An IPv4 address for the header Ethernet parameters (IP address, mask, default gateway, physical

    configuration) Managers IP addresses

    IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-21

    Slide 20

    20| AET/TAC 8408 | July 2011

    Header using the GIE-P card (P4.3B or P4.3C) : 2 steps :

    FMX configuration : Declaration of IP/ISO addresses and interfaces (FR, P1/P2). Creation of Frame Relay connections. Configuration of Gateways (X25, P1/P2).

    Proxy configuration : Reading of the current configuration (Load Command). Modification of the configuration (Modify and Build). Loading of the configuration in the Proxy (Send).

    IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-22 IONOS-NMS for FMX Training handbook

    Slide 21

    21| AET/TAC 8408 | July 2011

    Management network equipments (GIE-P) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-23

    Slide 22

    22| AET/TAC 8408 | July 2011

    Frame Relay connections (GIE-P) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-24 IONOS-NMS for FMX Training handbook

    Slide 23

    23| AET/TAC 8408 | July 2011

    FMX Header configuration (GIE-P) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-25

    1.3.2. Proxy configuration (GIE-P) Slide 24

    24| AET/TAC 8408 | July 2011

    Proxy configuration (GIE-P) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

    Slide 25

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-26 IONOS-NMS for FMX Training handbook

    25| AET/TAC 8408 | July 2011

    IONOS-NMS : FMX network configuration Proxy configuration (GIE-P) :

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-27

    Slide 26

    26| AET/TAC 8408 | July 2011

    IONOS-NMS : FMX network configuration Proxy configuration (GIE-P) :

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-28 IONOS-NMS for FMX Training handbook

    1.3.3. GIE-S Configuration Slide 27

    27| AET/TAC 8408 | July 2011

    Header using the GIE-S card (P4.4A) :

    FMX configuration :

    Declaration of IP/ISO addresses, interfaces (FR, P1/P2) and identification number ( ID FMX ).

    Creation of Frame Relay connections.

    Configuration of IPv4 addresses ( Ethernet port, managers list ).

    IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-29

    Slide 28

    28| AET/TAC 8408 | July 2011

    Management network equipments (GIE-S) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-30 IONOS-NMS for FMX Training handbook

    Slide 29

    29| AET/TAC 8408 | July 2011

    Frame Relay connections (GIE-S) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-31

    Slide 30

    30| AET/TAC 8408 | July 2011

    Ethernet port and/or P1/P2 (GIE-S) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-32 IONOS-NMS for FMX Training handbook

    Slide 31

    31| AET/TAC 8408 | July 2011

    Managers IP addresses (GIE-S) :IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-33

    1.4. FMX network example Slide 32

    32| AET/TAC 8408 | July 2011

    IONOS-NMS : FMX network example (GIE-S)

    FR

    P2 P1

    Ethernet

    IONOS NMS

    FR

    FR

    1 2

    3 4 5

    IP iso = 1.0.1.0.0.0 IP iso = 1.0.2.0.0.0

    IP iso = 1.0.3.0.0.0 IP iso = 1.0.4.0.0.0 IP iso = 1.0.5.0.0.0

    IPv4 = 192.168.0.172

    IPv4 = 192.168.0.1

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-34 IONOS-NMS for FMX Training handbook

    Slide 33

    33| AET/TAC 8408 | July 2011

    Equipment table 1 :

    IP iso interface ID Name1.0.1.0.0.0 1 FMX 11.0.2.0.0.0 P2 next 2 FMX 21.0.4.0.0.0 P2 4 FMX 41.0.5.0.0.0 P2 5 FMX 5 1.0.3.0.0.0 FR 3 FMX 3 255.0.0.0.0.0 FR 0 Manager NB : 255.0.0.0.0.0 Type :other = Manager

    ROLE : HEADER

    TMN - P2 codirectional

    Equipment table 2 :

    IP iso interface ID Name1.0.2.0.0.0 0 FMX 21.0.1.0.0.0 P1 next 0 FMX 1255.0.0.0.0.0 P1 0 Manager1.0.4.0.0.0 FR 0 FMX 41.0.5.0.0.0 FR 0 FMX 5

    P1 codirectional - P2 codirectional

    IONOS-NMS : FMX network example (GIE-S)

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-35

    Slide 34

    34| AET/TAC 8408 | July 2011

    Equipment table 3 :

    IP iso interface ID Name 1.0.3.0.0.0 0 FMX 3 1.0.1.0.0.0 FR 0 FMX 1 255.0.0.0.0.0 FR 0 Manager P1 codirectional - P2 codirectional

    Equipment table 4 : 1.0.4.0.0.0 0 FMX 4 1.0.2.0.0.0 FR 0 FMX 2 1.0.1.0.0.0 FR 0 FMX 1 All equipments 1, 2, 3, 4 and 5 are Gateway 255.0.0.0.0.0 FR 0 Manager P1 codirectional - P2 codirectional

    Equipment table 5 : 1.0.5.0.0.0 0 FMX 5 1.0.4.0.0.0 FR 0 FMX 4 1.0.2.0.0.0 FR 0 FMX 2 1.0.1.0.0.0 FR 0 FMX 1 255.0.0.0.0.0 FR 0 Manager P1 codirectional - P2 codirectional

    IONOS-NMS : FMX network example (GIE-S)

    Caution : In case of PC Proxy (with GIE-P)

    equipments 3-4-5 are None gateway.

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-36 IONOS-NMS for FMX Training handbook

    1.5. FMX network management with IONOS-NMS Slide 35

    35| AET/TAC 8408 | July 2011

    FMX network management with IONOS-NMS :

    IONOS-NMS

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-37

    Slide 36

    36| AET/TAC 8408 | July 2011

    IONOS-NMS manages on FMX equipments only : FMX configuration/operation. Alarms management.

    2Mbps links between FMX are not managed in IONOS-NMS. They can be created in the network topology view. Its only a graphic and static view of the link (no specific alarm

    for the link).

    IONOS-NMS

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-38 IONOS-NMS for FMX Training handbook

    Slide 37

    37| AET/TAC 8408 | July 2011

    Create subnetworks.

    Create a network element (FMX).

    Create links between FMX.

    IONOS-NMS : FMX network configuration

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-39

    Slide 38

    38| AET/TAC 8408 | July 2011

    FMX configuration and exploitation (card, ports, connections,) with the LCT :IONOS-NMS : FMX network exploitation

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-40 IONOS-NMS for FMX Training handbook

    Slide 39

    39| AET/TAC 8408 | July 2011

    Alarms log :

    IONOS-NMS : management of Alarms

    Current alarms

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-41

    1.6. Exercise : Network of FMX Slide 40

    40| AET/TAC 8408 | July 2011

    Exercise : Network of FMX Address plan of FMX with GIE.S :

    GIE.SIP iso : 1.0.1.0.0.0

    GIE.SIP Add : 192.168.0.1/16IP iso : 1.0. 3.0.0.0

    GIE.SIP iso : 1.0.2.0.0.0

    GIE.SIP iso : 1.0.4.0.0.0

    A2 S

    Slot14

    A2 S

    Slot12

    A2 S

    Slot13

    A2 SSlot11

    FMX 2

    FMX 1 FMX 3

    FMX 4

    Header1

    22

    1

    1 1

    PC Server192.168.0.140255.255.0.0

    Eth.

    DLCI 1

    DLCI 3

    DLCI 2

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-42 IONOS-NMS for FMX Training handbook

    Slide 41

    41| AET/TAC 8408 | July 2011

    Management network equipment : Table FMX 1 :

    IP iso interface ID Name

    Table FMX 2 :IP iso interface ID Name

    Table FMX 3 :IP iso interface ID Name

    Table FMX 4 :IP iso interface ID Name

    Exercise : Network of FMX

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-43

    Slide 42

    42| AET/TAC 8408 | July 2011

    FR frames relay connections :DestinationSourceDLCI FMX 1 :

    DestinationSourceDLCI

    DestinationSourceDLCI

    FMX 2 :

    FMX 3 :

    DestinationSourceDLCI FMX 4 :

    Exercise : Network of FMX

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-44 IONOS-NMS for FMX Training handbook

    Slide 43

    43| AET/TAC 8408 | July 2011

    Configuration of the FMX Header (FMX 3) : IP link and P1-P2 link configuration of FMX 3 : Choose : RGT/P2 contra or codirectional IP v4 address : Subnetwork Mask : Default gateway :

    Manager Addresses : For the FMX Header :

    Exercise : Network of FMX IP link and P1/P2 link configuration :

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-45

    1.6.1. Correct version Slide 44

    44| AET/TAC 8408 | July 2011

    GIE.SIP iso : 1.0.1.0.0.0

    GIE.SIP Add : 192.168.0.1/16IP iso : 1.0. 3.0.0.0

    GIE.SIP iso : 1.0.2.0.0.0

    GIE.SIP iso : 1.0.4.0.0.0

    A2 S

    Slot14

    A2 S

    Slot12

    A2 S

    Slot13

    A2 SSlot11

    FMX 2

    FMX 1 FMX 3

    FMX 4

    DLCI 2 DLCI 3

    DLCI 1

    DLCI 3

    Header1

    22

    1

    1 1

    PC Server192.168.0.140255.255.0.0

    Eth.

    DLCI 2DLCI 1DLCI 2

    Address plan of FMX with GIE.S :Correct version : Network of FMX

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-46 IONOS-NMS for FMX Training handbook

    Slide 45

    45| AET/TAC 8408 | July 2011

    Table FMX 1 :IP iso interface ID Name1.0.1.0.0.0 0 FMX 11.0.3.0.0.0 FR 0 FMX 3255.0.0.0.0.0 FR 0 Manager

    Table FMX 2 :IP iso interface ID Name1.0.2.0.0.0 0 FMX 21.0.3.0.0.0 FR 0 FMX 3255.0.0.0.0.0 FR 0 Manager

    Table FMX 3 :IP iso interface ID Name1.0.1.0.0.0 1 FMX 11.0.2.0.0.0 FR 2 FMX 21.0.3.0.0.0 FR 3 FMX 31.0.4.0.0.0 FR 4 FMX 255.0.0.0.0.0 FR 0 Manager

    Table FMX 4 :IP iso interface ID Name1.0.4.0.0.0 0 FMX 41.0.3.0.0.0 FR 0 FMX 3255.0.0.0.0.0 FR 0 Manager

    Correct version : Network of FMX Management network equipment :

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-47

    Slide 46

    46| AET/TAC 8408 | July 2011

    A2S ; Slot14 ; port 2; bits 7 and 8 (8Kbps)1.0.2.0.0.0

    A2S ; Slot14 ; port 1; bits 7 and 8 (8Kbps)1.0.3.0.0.0

    2

    A2S ; Slot14 ; port 1; bits 7 and 8 (8Kbps)1.0.3.0.0.0

    GIE (64Kbits/s)1.0.1.0.0.0

    1DestinationSourceDLCI FMX 1 :

    A2S ; Slot13 ; port 1; bits 7 and 8 (8Kbps)1.0.3.0.0.0

    GIE (64Kbits/s)1.0.2.0.0.0

    2DestinationSourceDLCI

    A2S ; Slot12 ; port 2; bits 7 and 8 (8Kbps)1.0.4.0.0.0

    GIE (64Kbits/s)1.0.3.0.0.0

    3

    A2S ; Slot12 ; port 1; bits 7 and 8 (8Kbps)1.0.2.0.0.0

    GIE (64Kbits/s)1.0.3.0.0.0

    2

    A2S ; Slot12 ; port 1; bits 7 and 8 (8Kbps)1.0.1.0.0.0

    GIE (64Kbits/s)1.0.3.0.0.0

    1DestinationSourceDLCI

    FMX 2 :

    FMX 3 :

    A2S ; Slot11 ; port 1; bits 7 and 8 (8Kbps)1.0.3.0.0.0

    GIE (64Kbits/s)1.0.4.0.0.0

    3DestinationSourceDLCI FMX 4 :

    Correct version : Network of FMX FR frames relay connections :

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-48 IONOS-NMS for FMX Training handbook

    Slide 47

    47| AET/TAC 8408 | July 2011

    Correct version : Network of FMX IP link and P1/P2 link configuration :

    Configuration of the FMX Header (FMX 3) : IP link and P1-P2 link configuration of FMX 3 : Choose : RGT/P2 contra or codirectional IP v4 address : 192.168.0.1 Subnetwork Mask : 255.255.0.0 Default gateway : 192.168.0.140 (router @).

    Manager Addresses : For the FMX Header : 192.168.0.140

    ______________________________________________________________________________________________

    ___________________________________________________________________________________________

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-49

    1.7. Process 1.7.1. ATLANTIS card configuration on PC Proxy

    Access path to ATLANTIS card parameters :

    Start > Settings > Control Panel Double click on Network Connections icon > Service > ATLANTIS- Header X25/ISDN (Prima P2) > Properties.

    Click on VOIE A & Then on 2 Inside the tools bar.

    Type of data circuit DB25

    Type of protocol X25

    Type of Network Transpac-(FR)

    Type of behaviour TERM / DTE or DCE

    Recovery block nX25

    Disconnections on exit appli Transmission of nX25

    Timer of network disconnection Reception of nX25

    Transmission of NUI

    Click on 4 To see the second window

    n of assigned VL 1 Flow ctrl parameters

    Number of CVP 0 Transmitted block window 2

    Number of incoming VL 0 Received block window 2

    n of low mixed VL 1 Transmitted block size 256

    n of high mixed VL 128 Received block size 256

    n of low outgoing VL

    n of high outgoing VL

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-50 IONOS-NMS for FMX Training handbook

    Click on 4

    Link layer: Physical layer:

    K Frame window 7 Clock External x If DTE

    N2 meter 10 Internal x If DCE

    T1 Temporisation 20 Speed rate 64000

    Disc before SABM Line interface V24/V28

    Transmission of XID Management command

    Management signal DTR

    Waiting tempo DSR 3

    Management signal RI

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-51

    1.7.2. Creation of a FMX (GIE-P Header) on IONOS-NMS

    I Creation of NE on IONOS-NMS : - Open NMS Client. - Create a NE. - Type : FMX P4.3C. - Give a name. - Give a Equipment number ( has to be unique ). - Give the PC Proxy IP address. - Tick the under Proxy box. - Create 2Mbps interface ( virtual, only for style of drawing ).

    II PC Proxy configuration :

    1. Launch Proxy Configuration from a PC Client.

    2. Verify FTP PROFILE

    - Click on A then on Modify . - Give the PC Proxy address. - Give User, password and port of the PC Proxy ( ex : administrator ; SaGeM ; 21 ).

    3. Make a Load to load all information from the PC Proxy to the PC client. (systematic if we dont want to run over the Proxy configuration)

    4. Verify the Configuration

    - Proxy : X25@ = 00141 - Manager : IP@ of PC server; ex : 192.168.0.140 - BMX : Configuration of FMX; Make ADD to add one FMX. - ID : Has to correspond to the equipment number of FMX given at the creation of

    the NE on IONOS-NMS. - Name : name of the FMX. - @X25 : X25 address of the FMX in gateway mode; ex : 00541 - @IP : IPiso address of the FMX; ex : 1.0.0.0.0.1

    5. If we did some modifications ( ex : add FMX )

    Make a Built ( we have to be in FTP Profile to turn accessible Built, Load and Send keys).

    Then make a Send : Tick the Proxy Reboot box ( modifications will take in count only after a

    reboot of the PC Proxy ) Send

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-52 IONOS-NMS for FMX Training handbook

    1.7.3. GIE-S card configuration in header mode

    1- Menu Configuration / general parameters select Gateway

    2- Menu management network / TMN link and P1-P2 link configuration

    Select TMN/P2

    Give the IP address of the FMX Ethernet port ( J129 ) mask and gateway.

    3- Menu management network / Manage network Equipment :

    4- Change the FMX address ( by default 1.0.0.0.0.0 )

    5- Give a FMX ID ( It will be the same one used when creating the NE on IONOS )

    6- Add all FMX reachable by this equipment ( address + ID + (type = FMX )+ name + (interface = Frame relay or P2 ))

    7- Add NMS ( type other ; ID = 0 ; @ IPv6= 255.0.0.0.0.0 and a name)

    8- Menu Management network / Managers Address

    Add all NMS IP addresses managing this equipment.

    9- Menu Management network / Frame relay connections

    Add all frame relay connection

    A- Give a name and a DLCI number ( 1 to 1024 )

    B- Give IP iso addresses for source and destination entities

    C- Select a rate ( 8kbits/s = 2 bits of TS0; 64 kbits/s = GIE or TS different of TS0 )

    D- Select source and destination entities ( GIE is always already relayed )

    In any case GIE will be always selected as a source.

  • 8408 IONOS-NMS for FMX July 2011 issue

    IONOS-NMS for FMX Training handbook Page 1-53

    1.7.4. GIE-S card configuration in non-header mode

    1- Menu Configuration / general parameters select Gateway

    2- Menu management network / TMN link and P1-P2 link configuration

    Select P1/P2 (ex: P1 co-directional /P2 co-directional )

    3- Menu management network / Manage network Equipment :

    4- Change the FMX address ( by default 1.0.0.0.0.0 )

    5- Give a FMX ID = 0

    6- Add all FMX reachable by this equipment ( address + ID=0 + type = FMX + name + interface = Frame relay or P1 or P2 )

    7- Add NMS ( type other ; ID = 0 ; @ IPv6= 255.0.0.0.0.0 and a name)

    8- Menu Management network / Managers Address

    No need to put NMS address ( done by the header ).

    9- Menu Management network / Frame relay connections

    A- Add all frame relay connection

    B- Give a name and a DLCI number ( 1 to 1024 )

    C- Give IP iso addresses for source and destination entities

    D- Select a rate ( 8kbits/s = 2 bits of TS0; 64 kbits/s = GIE or TS different of TS0 ) for source and destination

    E- Select source and destination entities ( GIE is always already relayed )

    In any case GIE will be always selected as a source.

  • 8408 IONOS-NMS for FMX July 2011 issue

    Page 1-54 IONOS-NMS for FMX Training handbook


Recommended