+ All Categories
Home > Documents > 8kW Hybrid Inverter - Lighting, Electrical, Solar PV ...

8kW Hybrid Inverter - Lighting, Electrical, Solar PV ...

Date post: 02-Mar-2022
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
2
www.ellies.co.za IP65 weather proofing 8kW Hybrid Inverter Renewable Energy Product Code: Features and Benefits Packaging Contents 1 x 8kW Hybrid Inverter 1 x Installation Screws (1 pack) 1 x Temperature Sensor Probe 1 x CT 100Amp 50mA Multiple Built-In MPPTs • It allows for multiple panel orientations • All strings on each MPPT needs to be identical in terms of quantity and size of panels, azimuth and tilt • Efficient charging algorithm offered by MPPT charging allows you to get more form you PV array Built-in Grid Limiter When grid-tied systems generate more power from the solar panels than what is required by the appliances in your home or business, the excess power can flow back through your electricity meter to the national electricity grid which is not allowed. Grid Limiting / Active Power Limitation decreases the output from the solar panels to match the consumption of your appliances. This ensures that no power flows back to the grid Monitoring and ease of configuration Through the new and updated User Interface on the built-in touch LCD display you can get access to: All required settings (password protected) • Daily / Monthly energy generated and Consumed • Real-time system information • Battery status and usage Sunsynk also offers Wi-Fi and GSM communication devices that allow remote monitoring via a cell phone app as well as remote technical assistance Smart Load Smart load is a method of making grid-tied systems with grid limiting more efficient. Instead of losing out on potential generation from your panels because of grid limiting, the smart load function allows you to power appliances, that are not connected to your battery bank, directly from the solar panels In short, once the battery is full and all loads connected to the inverter are supplied, electricity will flow from the solar panels to loads such as geysers, large air-conditioning units or pumps. Only once these have been supplied will the system be throttled meaning that more of you solar power can be consumed. Time of use charging / Peak shaving Some electricity suppliers provide electricity at different tariffs at different times during the day. This is mainly to discourage electricity usage in peak times when the grid is under more pressure. Special Smart electricity meters administrate this. Using the Sunsynk’s Time of Use functionality to charge the batteries when electricity is cheaper and then using the stored energy when electricity is more expensive Overview A highly efficient power management tool that allows the user to hit their electricity consumption targets by managing power from multiple energy sources. These include solar panels, the national electricity grid, a generator or even a wind turbine. The energy can be effectively stored as well which allows for power whenever it is needed. The Sunsynk inverter can operate without a battery to save you electricity, to working as an Uninterrupted Power Supply with no panels, to combining both sources to operate like a hybrid system Programmable export Single or 3-phase operation FBIHSK8K48P
Transcript

www.ellies.co.za

IP65weatherproofing

8kW Hybrid Inverter

Rene

wab

leEn

ergy

Product Code:

Features and Benefits

Packaging Contents1 x 8kW Hybrid Inverter 1 x Installation Screws (1 pack)1 x Temperature Sensor Probe1 x CT 100Amp 50mA

Multiple Built-In MPPTs• It allows for multiple panel orientations• All strings on each MPPT needs to be identical in terms of quantity and size of panels, azimuth and tilt• E�cient charging algorithm o�ered by MPPT charging allows you to get more form you PV array

Built-in Grid LimiterWhen grid-tied systems generate more power from the solar panels than what is required by the appliances in your home or business, the excess power can flow back through your electricity meter to the national electricity grid which is not allowed. Grid Limiting / Active Power Limitation decreases the output from the solar panels to match the consumption of your appliances. This ensures that no power flows back to the grid

Monitoring and ease of configurationThrough the new and updated User Interface on the built-in touch LCD display you can get access to:All required settings (password protected) • Daily / Monthly energy generated and Consumed • Real-time system information • Battery status and usageSunsynk also o�ers Wi-Fi and GSM communication devices that allow remote monitoring via a cell phone app as well as remote technical assistance

Smart LoadSmart load is a method of making grid-tied systems with grid limiting more e�cient. Instead of losing out on potential generation from your panels because of grid limiting, the smart load function allows you to power appliances, that are not connected to your battery bank, directly from the solar panels In short, once the battery is full and all loads connected to the inverter are supplied, electricity will flow from the solar panels to loads such as geysers, large air-conditioning units or pumps.Only once these have been supplied will the system be throttled meaning that more of you solar power can be consumed.

Time of use charging / Peak shavingSome electricity suppliers provide electricity at di�erent tari�s at di�erent times during the day. This is mainly to discourage electricity usage in peak times when the grid is under more pressure. Special Smart electricity meters administrate this.

Using the Sunsynk’s Time of Use functionality to charge the batteries when electricity is cheaper and then using the stored energy when electricity is more expensive

OverviewA highly e�cient power management tool that allows the user to hit their electricity consumption targets by managing power from multiple energy sources. These include solar panels, the national electricity grid, a generator or even a wind turbine. The energy can be e�ectively stored as well which allows for power whenever it is needed.The Sunsynk inverter can operate without a battery to save you electricity, to working as an Uninterrupted Power Supply with no panels, to combining both sources to operate like a hybrid system

Programmable export

Single or 3-phase operation

FBIHSK8K48P

Batter TypeBattery Voltage Range (V) Max. Charging Current (A)Max. Discharging Current (A)Charging CurveExternal Temperature SensorCharging Strategy for Li-ion Battery

Max. DC Input Power (W)Max. DC Input Voltage (V) MPPT Range (V)Start-up Voltage (V)Max. Input Current (A)No. of MPPT TrackersNo. of Strings Per MPPT Tracker

Rated AC Output and UPS Power (W)

Max. AC Current (A)Output Frequency and Voltage

Grid TypeCurrent Harmonic Distortion

PV Input Lightning ProtectionAnti-islanding ProtectionPV String Input Reverse PolarityProtectionInsulation Resistor DetectionResidual Current Monitoring UnitOutput Over Current ProtectionOutput Shorted ProtectionOutput Over Voltage Protection

Grid Regulation

Safety Regulation

South African Certifications

EMC

Operating Temperature Range (ºC)CoolingNoise (dB)Communication with BMSWeight (kg)Size (Length*Width*Height mm)Protection DegreeInstallation StyleWarranty

Lead-Acid or Li-ion40V-60V

3 Stages/EqualizationOptionalSelf-Adaption to BMS

500V 125V-425V150V

2 Times Rated Powerfor 10 Seconds

50, 230 VAC(Single Phase)

Single PhaseTHD<3% (Linear Load<1.5%)

97.60%99.90%96.50%

IntegratedIntegratedIntegrated

IntegratedIntegratedIntegratedIntegratedIntegrated

IEC62109-1&2, IEC62040-1EN61000-6-1, EN61000-6-3, FCC 15 class BNRS097-2-1: 2017Edition 2

-25~60ºC, >45 DeratingFan<30RS485; CAN32KG670x420x233mmIP65Wall-Mounted5 Years

190A190A

10400W

18A+18A22/2

8000W

33A

Battery Input Data

PV String Input Data

AC Output Data

Protection

General Data

Certifications and Standards

Specifications

Rene

wab

leEn

ergy

8kW Hybrid Inverter

UL1741, IEEE1547, RULE21, VDE0126, AS4777, NRS2017, G98,G99, IEC61683,IEC62116, IEC61727


Recommended