Date post: | 12-Oct-2015 |
Category: |
Documents |
Upload: | khinaungshwe |
View: | 48 times |
Download: | 1 times |
Heat Transfer Technology Worldwide
Your Complete Source for:
Temperature Sensors Heating Elements Process Controls
Complete Heating & Cooling Engineered Systems
Visit us at: WWW.ACROLAB.COM PHONE(800)265-9542 FAX:(800)465-9674
Serving you Since 1948
Thermal Manufacturing Solutions
Section Index
General Information Plastics Thermocouples and RTDs Industrial Thermocouples and RTDs Food, Dairy and Pharmaceutical Thermocouples and RTDs Explosion Proof Thermocouples and RTDs Thermowells Thermocouple and RTD Accessories Thermocouple, Extension and RTD Wire Heating Elements General Accessories Instruments Isobars Technical Information Application Information Distributed Products
Section A Section B Section C Section D Section E Section F Section G Section H Section I Section J Section K Section L Section M Section N Section O
Thermal Manufacturing Solutions
Section A General Information
Comments from a few of Our Satisfied Customers...
Acrolab always handles my requests in an efficient and professional manner. Acrolabs sales staff are friendly, in-formed and take time to address all of my needs and concerns. - Ford En-gine Plant, Windsor, ON Acrolabs products always meet my expectations for quality, function, and value. - Lear Corporation, Windsor, ON Acrolab does a great job! I get excel-lent value & customer servicethey also stream lined the process to make ordering fool proof and easy! - Ventra Plastics Group, Chatham, ON Acrolabs thermocouple designs have given us our best uptime record in 25 years. The sales and service supplied by Acrolabs staff was fantastic!
Acrolab is committed to supplying the highest quality products and services available. Acrolab has provided solutions for every industry from automotive, food processing, and mold-making, to electronics, aerospace and Oil & Gas, for over fifty years. Call anyone on the Acrolab team for a quote on your heating, sensor, or accessories needs and experience the value for yourself!
Acrolabs Thermal Control Technology has been used in many engineered thermal solutions worldwide for the past fifty years.We have supplied some of the largest companies in the world with critical and precise temperature control in a wide range ofindustries, such as Oil & Gas, Agricultural, Automotive, Aerospace, Plastics, Rubber, Power Generation, Military, Water Treatment, Pharmaceuticals, Electronics, Waste Management and more.
Acrolab offers custom engineered, manufactured and installed heat transfer and cooling systems which are aimed at providing customers with predictable, narrow, thermal windows and isothermal surfaces. These, in-turn, allow for precise, consistent and efficient control of processes, resulting in morepredictable quality and higher profitability.
Acrolab also manufactures high quality temperature sensors such as thermocouples and RTD assemblies, and is one of Canadas largest suppliers of industrial heaters and heat related products. No matter what industry you are in, if precise temperature control is an issue, call Acrolab Ltd. to find out how we can increase your profitability.
Acrolab is accredited to ISO9001:2000. Acrolab has won awards for business excellence, market expansion and industry leadership.
GEOTHERMAL
AGRICULTURAL
AUTOMOTIVE
POWER GENERATION
OIL AND GAS
HEAT TRANSFER TECHNOLOGY WORLDWIDE
Ph: 403-389-5440
Web: www.acrolab.com
Email: [email protected]
Toll Free In North America
Ph: 1-800-265-9542
Fax: 1-800-465-9674
NORTH AMERICA SOUTH AMERICA EUROPE ASIA
Heat Transfer technology Worldwide
Section B Plastics Industry Thermocouples and RTDs
Fixed Bayonet Style Thermocouples Fixed Compression Style Thermocouples Nozzle Style Thermocouples Melt Style Thermocouples Adjustable Bayonet Style Thermocouples Tube and Wire Style Thermocouples Gasket Style Thermocouples Ring Style Thermocouples Under The Band Style Thermocouples Thermocouple Extension Cables Pipe Clamp Adaptors
B-1 B-3 B-5 B-7 B-9 B-11 B-13 B-15 B-17 B-19 B-21
A100 STYLE
A145 STYLE
A190 STYLE
"A" "B"
3/16"
"B"
"A"
3/16"
45
1/2"
1 1/2"
"B"
"A"
90
3/16"
1/2"
1 1/2"
1/2"
FIXED BAYONET THERMOCOUPLESAND RTDs
B-1
Fixed bayonet thermocouples and RTD's are most commonly used in thePlastic Processing Industry. They can be used in many general applicationswhere a bayonet adaptor is preferred. As a standard, they are providedwith a 316SS sheath with SS square lock armoured leads.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
29 1/8" Diameter Probe
RTD/RTD2
RTD/RTD3
1. THERMOCOUPLE STYLE
RTD/RTD4
45 Fixed Bayonet Style
90 Fixed Bayonet Style
Straight Fixed Bayonet StyleA100
A145
A190
Dual Copper/Constantan
Dual 100 Ohm, 4 Wire
Dual 100 Ohm, 2 Wire
Dual 100 Ohm, 3 Wire
Dual Chromel/Alumel
TT
KK
49
09
AA
99
Standard Male Plug
Leads Not Stripped
5. TERMINATION TYPE
BX Connector & 4" StrippedLeads with Spade Lugs
4" Stripped Leads with
Standard Female Jack
2. CALIBRATION TYPE
T Copper/Constantan
100 Ohm, 2 Wire
Dual Iron/Constantan100 Ohm, 4 Wire
100 Ohm, 3 Wire
RTD2
RTD3
RTD4JJ
Iron/Constantan
Chromel/AlumelK
J
4. "B" LENGTHSpecify in Inches
3. "A" LENGTH
2
Spade Lugs4
3
1
0
Special Construction, Describe
Fiberglass Wire with Stainless
1/4" Diameter Probe
Steel Overbraid
FIXED BAYONET THERMOCOUPLES
6. OPTIONS
W
U
A - -1 2 4 53- -
AND RTDs
6
Ungrounded (3/16" OD Standard)
Welded Construction
B-2
Specify in Inches
Fiberglass Wire without Stainless
Steel Overbraid
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A245 STYLE
A290 STYLE
"A" "B"
3/16"
"B"
"A"
3/16"
45
1 1/2"
"B"
"A"
3/16"
1 1/2"
1/8" NPT BRASS
COMPRESSION FITTING
FIXED COMPRESSION THERMOCOUPLESAND RTDs
A200 STYLE
B-3
Fixed Compression thermocouple's and RTD's are commonly usedint the Plastics Processing Industry much like the fixed bayonetstyle are. The difference being is they are mounted using a 1/8" NPTcompression fitting. Other thread sizes are available upon request.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
3. "A" LENGTHSpecify in Inches
1. THERMOCOUPLE STYLE
90 Fixed Compression Style
45 Fixed Compression Style
Straight Fixed Compression Style
A290
A245
A200
Steel Overbraid
1 Standard Male Plug
Standard Female PlugBX Connector and 4" Stripped
4" Stripped Leads with Spade Lugs
Leads with Spade Lugs
Specify in Inches
4. "B" LENGTH
4
32
99
AA
5. TERMINATION TYPELeads not Stripped0
Special Construction, Describe
Ungrounded (3/16" OD Standard)
No Compression Fitting Required
6. OPTIONS
09
49
29
00W
U
Fiberglass Wire With Stainless
1/4" Diameter Probe
1/8" Diameter Probe
Welded Construction
B-4
AND RTDsFIXED COMPRESSION THERMOCOUPLES
Fiberglass Wire Without StainlessSteel Overbraid
21A -- 3 4- 6-5
2. CALIBRATION TYPE
100 Ohm, 3 Wire100 Ohm, 4 Wire
Iron/Constantan
Dual Iron/Constantan
Chromel/Alumel
Dual Chromel/Alumel
Copper/Constantan
Dual Copper/Constantan
100 Ohm, 2 Wire
Dual 100 Ohm, 2 Wire
Dual 100 Ohm, 3 WireDual 100 Ohm, 4 Wire
RTD3
RTD/RTD4
RTD/RTD2
RTD/RTD3
TT
JJ
KK
RTD4
T
RTD2
K
J
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A310 STYLE
"B"
"B"
A300 STYLE
3/8"
3/8"
1/4" - 28 N.F. THREAD
1/4" - 28 N.F. THREAD
NOZZLE STYLE THERMOCOUPLESAND RTDs
B-5
Threaded nozzle thermocouples and RTD's are commonly used to measure the temperatureof the nozzle on an injection moulding machine. The A300 and A310 style is a versatiledesign and may be used in a wide variety of applications where space is a factor. Acrolaboffers this style, as a standard, either with or without stainless steel armour and with a 1/4"-28N.F. threaded swivelling bolt. Other thread sizes, imperial or metric, are available.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
1. THERMOCOUPLE STYLEArmored Nozzle Style
Spring Relief Nozzle StyleA310
A300
IRON / CONSTANTANJ
DUAL 100 OHM, 4 WIREDUAL 100 OHM, 3 WIRE
DUAL 100 OHM, 2 WIRE
RTD/RTD4RTD/RTD3
RTD/RTD2
COPPER / CONSTANTAN
DUAL IRON / CONSTANTAN
DUAL COPPER / CONSTANTAN
DUAL CHROMEL / ALUMEL
100 OHM, 3 WIRERTD3100 OHM, 4 WIRE
TT
KKJJ
RTD4
CHROMEL / ALUMEL
100 OHM, 2 WIRET
K
RTD2
3. B" LENGTHSpecify in Inches
2. CALIBRATION TYPE
1 Standard Male Plug
Standard Female Jack
4
32
Leads Not Stripped
4. TERMINATION TYPE0
Steel Overbraid
Fiberglass Wire Without Stainless
Special Construction, Describe
UngroundedU
AA
99
5. OPTIONS
NOZZLE STYLE THERMOCOUPLESAND RTDs
B-6
21A - 3 - 5-4
6 x 1.0 x 10mm boltB1
8 x 1.25 x 16mm boltB2
Stainless Steel BoltSS
4" Stripped Leads with
Leads with Spade LugsBX Connector and 4" Stripped
Spade Lugs
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A400 STYLE
-
J
+
"A"
1/8"
B-7
PLASTIC MELT THERMOCOUPLES AND RTDs
33/64" 5/16"
27/64"
1/4"
3/8"
45
1"
1/4"
7/16"
"A".312 DIA
.421 DIA
1/2-20 N.F
"B"
Acrolab's melt bolt style thermocouples and RTD's are designed to directly measure the melttemperature of plastic as it moves down the extruder barrel . They are commonplace in the
lengths, as well as offering many other leadwire and termination options.extrusion and plastic injection moulding industries. Acrolab offers them in a variety of bolt
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A410 Adjustable Melt Style
1. THERMOCOUPLE STYLEPlastic Melt StyleA400
Standard Female Jack2
4" Stripped Leads with Spade Lugs
with Spade LugsBX Connector & 4" Stripped Leads3
4
Special Construction, Describe
5. TERMINATION TYPELeads Not Stripped
Standard Male Plug
0
1
AA
Ungrounded (3/16" OD Standard)
6. OPTIONSU
PLASTIC MELT THERMOCOUPLES AND RTDs
B-8
-A 1 2 - -3 4 -5 6
Specify in Inches
3. "A" LENGTH
4. "B" LENGTH
6" SS Melt Bolt
4" SS Melt Bolt
8" SS Melt Bolt
12" SS Melt Bolt10" SS Melt Bolt
3" SS Melt Bolt
1012
6
8
4
3
2. CALIBRATION TYPE
100 Ohm, 3 Wire
100 Ohm, 4 Wire
Iron/Constantan
Dual Iron/Constantan
Chromel/Alumel
Dual Chromel/Alumel
Copper/Constantan
Dual Copper/Constantan
100 Ohm, 2 Wire
Dual 100 Ohm, 2 Wire
Dual 100 Ohm, 3 Wire
Dual 100 Ohm, 4 Wire
RTD3
RTD/RTD4
RTD/RTD2
RTD/RTD3
TT
JJ
KK
RTD4
T
RTD2
K
J
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A500 STYLE
A510 STYLE
9/16"
9/16"
1/4"
1/4"
"B"
"B"
11 1/2" ADJUSTABLE
ADJUSTABLE BAYONET STYLE THERMOCOUPLESAND RTDs
B-9
Acrolab's adjustable bayonet style thermocouples and RTD's are designed forapplications where quick installation and disconnect is required with the useof a bayonet adaptor. Acrolab offers them wtih SS armour allowing the sensorto be fully adjustable along it's entire "B" length, or with a 12" long spring.Metric dual slot caps are available upon request.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Fiberglass Wire Without Stainless
Ungrounded (3/16" OD Standard)
ADJUSTABLE BAYONET STYLE THERMOCOUPLES
Special Construction, Describe
99
1. THERMOCOUPLE STYLEArmored Adjustable Bayonet Style
Spring Adjustable Bayonet StyleA510
A500
Standard Female Jack2BX Connector & 4" Stripped
4" Stripped Leads with
Leads with Spade Lugs
Spade Lugs
Specify in Inches
3. B" LENGTH
4
3
Leads Not Stripped
Standard Male Plug
4. TERMINATION TYPE0
1
Steel Overbraid
AAU
3/16" Diameter Probe
1/8" Diameter Probe
39
29
5. OPTIONS
AND RTDs
B-10
A -1 2 -3 -4 5
2. CALIBRATION TYPE
100 Ohm, 3 Wire100 Ohm, 4 Wire
Iron/Constantan
Dual Iron/Constantan
Chromel/Alumel
Dual Chromel/Alumel
Copper/Constantan
Dual Copper/Constantan
100 Ohm, 2 Wire
Dual 100 Ohm, 2 Wire
Dual 100 Ohm, 3 WireDual 100 Ohm, 4 Wire
RTD3
RTD/RTD4
RTD/RTD2
RTD/RTD3
TT
JJKK
RTD4
T
RTD2
K
J
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A520 STYLE
"A"
AND RTDsPROBE STYLE TUBE AND WIRE THERMOCOUPLES
B-11 Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Acrolab's A520 style Thermocouple's and RTD's are a low cost tube and wire altenativeto Magnesium Oxide (MgO) styles. They are available in the common calibrations forThermocouples as well as 2, 3 or 4 wire for RTD's.
1/4"
U Ungrounded (3/16" OD Standard)
DUAL IRON / CONSTANTANJJ
1. THERMOCOUPLE STYLEProbe Style Tube and WireA520
DUAL CHROMEL / ALUMEL
DUAL 100 OHM, 2 WIRE
DUAL 100 OHM, 3 WIRE
DUAL 100 OHM, 4 WIRE
DUAL COPPER / CONSTANTAN
RTD/RTD4
RTD/RTD2
RTD/RTD3
KK
TT
Spade Lugs
4. "B" LENGTH
4" Stripped Leads with
Standard Male Plug
Leads with Spade Lugs
Standard Female JackBX Connector & 4" Stripped
Leads Not Stripped
5. TERMINATION TYPE
Specify in Inches
IRON / CONSTANTAN
100 OHM, 3 WIRE
100 OHM, 2 WIRE
COPPER / CONSTANTAN
100 OHM, 4 WIRE
CHROMEL / ALUMEL
2. CALIBRATION TYPE
T
RTD3
RTD2
RTD4
J
K
3. "A" LENGTHSpecify in Inches
3
4
0
2
1
1/8" Diameter Probe
3/16" Diameter ProbeFiberglass Wire Without Stainless
Welded Construction
Special Construction, Describe
Steel Overbraid
AA
39
29
99
W
PROBE STYLE TUBE AND WIRE THERMOCOUPLESAND RTDs
6. OPTIONS
B-12
1 2A -- 4- 3 6-5
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A600 STYLE
BRASS WASHER
"B"
A-A
1/8"
1.0"
1/4"
A-A
RTDTHERMOCOUPLE
GASKET STYLE THERMOCOUPLES AND RTDs
B-13
Acrolab's gasket style thermocouples and RTD's are a more heavy duty version of theA700 and A710 ring style. The heavy duty brass washer is reinforced with a strainrelief fork crimped to the leadwire. They are ideal for surface temperature measurementas are the ring style sensors.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
U Ungrounded
2. CALIBRATION TYPE
1. THERMOCOUPLE STYLE
RTD/RTD4
Gasket StyleA600
T
KK
RTD/RTD3
RTD/RTD2TT
RTD2
RTD3
JJ
RTD4
J
K
DUAL 100 OHM, 4 WIRE
COPPER / CONSTANTAN
DUAL CHROMEL / ALUMEL
DUAL 100 OHM, 3 WIRE
DUAL 100 OHM, 2 WIREDUAL COPPER / CONSTANTAN
DUAL IRON / CONSTANTAN
100 OHM, 3 WIRE
100 OHM, 2 WIRE
100 OHM, 4 WIRE
IRON / CONSTANTAN
CHROMEL / ALUMEL
3. B" LENGTHSpecify in Inches
Forks Exiting 90 from Gasket
Special Construction, Describe
Fiberglass Wire Without Stainless
Leads Not Stripped
Standard Female Jack
Leads with Spade Lugs
Standard Male Plug
4" Stipped Leads with Spade Lugs
BX Connector & 4" Stripped
4
0
23
1
4. TERMINATION TYPE
AA
Steel Overbraid99
9D
GASKET STYLE THERMOCOUPLES AND RTDs
5. OPTIONS
B-14
A 1 2 - 3 -4 5-
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A710 STYLE
"B"
A700 STYLE
#10 COPPER WASHER
"B"
#10 COPPER WASHER
#10 COPPER WASHER
RING STYLE THERMOCOUPLES AND RTDs
B-15
Acrolab's ring style thermocouples and RTD's are designed for any surface measurementapplication. They are attached to a surface simply with a screw or bolt. The are availablewith SS Armoured leads or SSOB leads. Many washer sizes and lead types are availableupon request.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A710
A700
1. THERMOCOUPLE STYLE
Ring Style with SS Braid
Ring Style with SS Armor
Specify in Inches
Leads Not Stripped
BX Connector & 4" Stripped
4" Stripped Leads with Spade Lugs
Standard Male Plug
Leads with Spade Lugs
Standard Female Jack
4. TERMINATION TYPE
1
4
3. B" LENGTH
23
0
Fiberglass Wire Without Stainless
Special Construction, Describe
Steel Overbraid
Hi Temperature Washer
99
AA
MUngroundedU
5. OPTIONS
RING STYLE THERMOCOUPLES AND RTDs
B-16
1A - 32 -4- 5
#6 Copper Washer6
2. CALIBRATION TYPE
100 Ohm, 3 Wire
100 Ohm, 4 Wire
Iron/Constantan
Dual Iron/Constantan
Chromel/Alumel
Dual Chromel/Alumel
Copper/Constantan
Dual Copper/Constantan
100 Ohm, 2 Wire
Dual 100 Ohm, 2 Wire
Dual 100 Ohm, 3 WireDual 100 Ohm, 4 Wire
RTD3
RTD/RTD4
RTD/RTD2
RTD/RTD3
TT
JJ
KK
RTD4
T
RTD2
K
J
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A810 STYLE
"B"
A800 STYLE
"B"
"C"
"D"
"D"
"C"
B-17
UNDER THE BAND STYLE THERMOCOUPLESAND RTDs
Under the Band style thermocouples and RTD's are a variety of surface measurementsensors. They are commonly used in pipes and held in place with the use of a pipeclamp, or on barrels and nozzles under a band heater. Acrolab offers these with a brassshim as a standard, but are available with SS upon request.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
AA Special Construction, Describe
JJ DUAL IRON / CONSTANTAN
DUAL CHROMEL / ALUMEL
DUAL 100 OHM, 4 WIRE
DUAL 100 OHM, 3 WIRE
DUAL 100 OHM, 2 WIRE
Under the Band Style with SS Braid
Under the Band Style with SS Armor
DUAL COPPER / CONSTANTAN
1. THERMOCOUPLE STYLEA800
A810
RTD/RTD3
RTD/RTD4
RTD/RTD2
KK
TT
6. TERMINATION TYPE
Standard Female Jack
Leads with Spade Lugs
Standard Male Plug
4" Stripped Leads with Spade Lugs
BX Connector & 4" Stripped
Leads Not Stripped
IRON / CONSTANTAN2. CALIBRATION TYPE
100 OHM, 3 WIRE
100 OHM, 2 WIRE
100 OHM, 4 WIRE
COPPER / CONSTANTAN
CHROMEL / ALUMEL
T
RTD3
RTD2
RTD4
J
K
Specify in Inches
4. "C" LENGTH
3. "B" LENGTHSpecify in Inches
5. "D" LENGTHSpecify in Inches
4
0
23
1
Stainless Steel Shim
UNDER THE BAND STYLE THERMOCOUPLES
Ungrounded
Stainless Steel OverbraidFiberglass Wire Without
7. OPTIONS
SSU
99
AND RTDs
B-18
721A - 4 -3- -5 -6
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
A900 STYLE
-
+
J
"B"
THERMOCOUPLE AND RTD EXTENSION CABLES
B-19
Thermocouple and RTD extension cables are availabe with a wide variety of leadwires andprotection such as SS armour and over braid, as well as many termination options andlengths. They are used to provide connections between sensors, jack panels or variousinstrumentation.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
5. "Y" TERMINATION0
1M
1
2M
3
2
4
4. "X" TERMINATION
100 OHM, 4 WIRERTD4
A810
A800
1. THERMOCOUPLE STYLEArmored Extension Cable
Stainless Steel Over Braid Extension Cable
DUAL CHROMEL / ALUMEL
DUAL COPPER / CONSTANTAN
DUAL IRON / CONSTANTAN
DUAL 100 OHM, 3 WIRE
DUAL 100 OHM, 4 WIRE
DUAL 100 OHM, 2 WIRERTD/RTD2
RTD/RTD3
RTD/RTD4
JJKK
TT
IRON / CONSTANTAN
COPPER / CONSTANTAN
CHROMEL / ALUMEL
2. CALIBRATION TYPE
100 OHM, 2 WIRE
100 OHM, 3 WIRE
K
T
RTD2
RTD3
J
3. "B" LENGTHSpecify in Inches
4" Stripped Leads with Spade Lugs
BX Connector & 4" StrippedLeads with Spade Lugs
Miniature Female Jack
Standard Female JackMiniature Male Plug
Standard Male Plug
Leads Not Stripped
THERMOCOUPLE AND RTD EXTENSION CABLES
Fiberglass Wire With Stainless
Special Construction, Describe
Fiberglass Wire Without Stainless99Steel Overbraid (no armor)
AA
6. OPTIONS9
B-20
A -1 2 - 5-3 - 6
Steel Overbraid
Miniature Male Plug1M
2M
4" Stripped Leads with Spade Lugs
Leads with Spade LugsBX Connector & 4" Stripped
Miniature Female Jack
Standard Female Jack
3
4
2
Standard Male Plug
Leads Not Stripped0
1
4
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
PIPE CLAMP ADAPTORS
BA-24
BA-25
BA-26
BA-20
BA-21
BA-23
BA-22
PART NUMBER
2 1/4" TO 3 1/4"
4 1/4" TO 5"
3 1/4" TO 4 1/4"
1/2" TO 7/8"
1 1/4" TO 2"
2" TO 2 1/2"
7/8" TO 1 1/4"
FITS OUTSIDE DIAMETER
B-21
INSIDE DIAMETER
Pipe clamps are used in conjunction with Acrolab's A100, A145,A190, A500 and A510 series bayonet style thermocouples. Theyare designed for temperature measurement on the outside of
Pipe clamps are an economical and efficient design that requiresno machining or tapping to mount them. Custom diametersand bayonet adaptor locations are also available.
a pipe.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Thermal Manufacturing Solutions
Section C Industrial Thermocouples and RTDs
Straight Base Metal Thermocouple Elements Angle Base Metal Thermocouple Elements Straight Noble Metal Thermocouple Elements Metal Protection Tubes Straight Thermocouples Assemblies With Metal Protection Tubes Angle Thermocouples Assemblies With Metal Protection Tubes Straight Ceramic Protection Tubes Straight Thermocouple Assemblies with Ceramic Protection Tubes Straight Thermocouple Assemblies with Double Protection Tubes MgO Insulated Thermocoplues Resistance Temperature Detectors (RTDs) Tubeskin Thermocouples
C-1 C-3 C-5 C-7 C-9 C-11 C-13 C-15 C-17 C-19 C-29 C-39
C-1
STRAIGHT BASE METAL THERMOCOUPLE
BARE ALLOY (ALL GAUGES)
BALL AND SOCKET (8 AND 14 GAUGE ONLY)
CERAMIC INSULATORS (8, 11, 14 AND 18 GAUGE ONLY)
2.5"
2.5"
ELEMENTS
Straight base metal thermocouple elements are designed asreplacement elements for use in protection tube assemblies.Various calibrations, gauges, insulator styles and junctionsare available.
TWIST AND WELD
BUTT WELD
INSULATED JUNCTION
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
TYPE K, SINGLE
TYPE J, SINGLE
TYPE K, DUAL
TYPE N, DUAL
TYPE J, DUAL
-
TYPE N, SINGLE
DESCRIPTION
REFRACTORY INSULATORS (2475F MAX.)J, K, AND N SUPPLIED WITH
DESCRIPTION
IS 2.5" LONGER THAN SPECIFIED TO
ACTUAL LENGTH PROVIDED
ALLOW FOR TERMINAL CONNECTIONS
XXX
024
036
018
030
012
COMPLETE ORDERNUMBER -1 2 3 4 5
EXAMPLE PART NUMBER: K8CI-012-1
CODE
J
K
JJ
NN
KK
N
1. CALIBRATION
2. WIRE GAUGECODE
20
14
8
11
8 GAUGE (J, K AND N ONLY)
11 GAUGE (J AND K ONLY)
14 GAUGE (J, K AND N ONLY)
20 GAUGE (J AND K ONLY)
DESCRIPTION
3. INSULATIONCODE
NO INSULATORS, BARE ALLOY00
B - BALL AND SOCKETB
CI - CERAMIC INSULATOR, TWOCI
HOLE, OVAL
4. LENGTH (IN INCHES)CODE DESCRIPTION
12" LONG
30" LONG
36" LONG
SPECIFY (IN 1" INCREMENTS)
18" LONG
24" LONG
OTHER (DESCRIBE)
1 TWIST AND WELDED JUNCTION
342
L
AA
341
2
DUPLEX TERMINAL BLOCK
ISOLATED JUNCTION
BUTT WELDED JUNCTION
SINGLE TERMINAL BLOCK
5. OPTIONSCODE DESCRIPTION
K8CI = TYPE K, 8 GAUGE, CERAMIC INSULATORS012 = 12" LONG1 = TWIST AND WELDED JUNCTION
C-2
STRAIGHT BASE METAL THERMOCOUPLEELEMENTS
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-3
HO
T L
EG
LEN
GTH
COLD LEG LENGTH
APPROX
. 4.0"
ANGLE BASE METAL THERMOCOUPLEELEMENTS
2.5"
Various calibrations, gauges, insulator styles and junctions
Angle base metal thermocouple elements are designed asreplacement elements for use in protection tube assemblies.
are available.INSULATED JUNCTION
TWIST AND WELD
BUTT WELD
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
4321NUMBER -COMPLETE ORDER 5 6-
4. HOT LENGTH (IN INCHES)
14 GAUGE (J, K AND N)14
11 11 GAUGE (J AND K ONLY)
CODE
2. WIRE GAUGE
8
DESCRIPTION
8 GAUGE (J, K AND N)
30" LONG030
SPECIFY (IN 1" INCREMENTS)XXX
036 36" LONG
DESCRIPTION
024
018
24" LONG
18" LONG
CODE
012 12" LONG
JJ TYPE J, DUAL
NN
KK
TYPE N, DUAL
TYPE K, DUAL
N
K
TYPE N, SINGLE
TYPE K, SINGLE
1. CALIBRATIONCODE
J
DESCRIPTION
TYPE J, SINGLE
HOLE, OVAL
J, K, AND N SUPPLIED WITH
CI - CERAMIC INSULATOR, TWO
REFRACTORY INSULATORS (2475F MAX.)
CI
DUPLEX TERMINAL BLOCK
SINGLE TERMINAL BLOCK
ISOLATED JUNCTIONL
OTHER (DESCRIBE)AA
342
341
CODE
6. OPTIONS
B - BALL AND SOCKET
DESCRIPTION
NO INSULATORS, BARE ALLOY
CODE
00
B
3. INSULATION
BUTT WELDED JUNCTION
TWIST AND WELDED JUNCTION
DESCRIPTION
1
2
SPECIFY (IN 1" INCREMENTS)
24" LONG
36" LONG
30" LONG
ALLOW FOR TERMINAL CONNECTIONS
IS 2.5" LONGER THAN SPECIFIED TO
ACTUAL LENGTH PROVIDED
036
XXX
024
030
12" LONG
18" LONG
5. COLD LENGTH (IN INCHES)CODE
018
012
DESCRIPTION
K8CI = TYPE K, 8 GAUGE, CERAMIC INSULATORS
024 = 24" LONG COLD LEG
EXAMPLE PART NUMBER: K8CI-012-24-1
012 = 12" LONG HOT LEG
1 = TWIST AND WELDED JUNCTION
C-4
ANGLE BASE METAL THERMOCOUPLEELEMENTS
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
STRAIGHT NOBLE METAL THERMOCOUPLE
C-5
ALUMINA INSULATOR
ELEMENTS
2.5"
Noble metal thermocouple elements are designed as replacementelements for use in high temperature protection tube assemblies.Various calibrations, gauges, insulator styles and junctionsare available.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
ACTUAL LENGTH PROVIDED
2. WIRE GAUGE
TYPE S, SINGLE
TYPE B, DUAL
TYPE S, DUAL
TYPE R, DUALRR
SS
BB
S
DESCRIPTION
1. CALIBRATION
TYPE B, SINGLE
TYPE R, SINGLE
CODE
B
R
24
26
CODE
EXAMPLE PART NUMBER: R26CI-012-2
R26CI = TYPE R, 26 GAUGE, ALUMINA INSULATOR012 = 12" LONG2 = BUTT WELDED JUNCTION
C-6
26 GAUGE (R AND S ONLY)
24 GAUGE (B, R AND S)
DESCRIPTION
CI - CERAMIC INSULATOR, TWO
NO INSULATORS, BARE ALLOY
ALLOW FOR TERMINAL CONNECTIONS
IS 2.5" LONGER THAN SPECIFIED TO
INSULATORS - 3400F MAX. (1871 C)
00
HOLE, OVAL
SUPPLIED WITH 99.7% ALUMINA
CI
3. INSULATIONCODE DESCRIPTION
-COMPLETE ORDERNUMBER 1 2
DESCRIPTION
SINGLE TERMINAL BLOCK
BUTT WELDED JUNCTION
ISOLATED JUNCTION
DUPLEX TERMINAL BLOCK
OTHER (DESCRIBE)
SPECIFY (IN 1" INCREMENTS)
DESCRIPTION
4. LENGTH (IN INCHES)
18" LONG018
030
036
024
XXX
36" LONG
24" LONG
30" LONG
CODE
012 12" LONG AA
342
2
L
341
-3 4
CODE
5. OPTIONS
5
STRAIGHT NOBLE METAL THERMOCOUPLEELEMENTS
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-7
OVERALL LENGTH
INSERTION LENGTH ("X")
OVERALL LENGTH
INSERTION LENGTH ("X")
OPTION H
OPTION C THROUGH G
METAL PROTECTION TUBES
The metal protection tubes found on these pages are replacement protectiontubes for Acrolab's complete metal protection tube thermocouple assemblies.Acrolab offers a variety of materials to suit your application requirements aswell as numerous options for mounting, etc...
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
COMPLETE ORDERNUMBER 1 2- - 3
24 = 24" OVERALL LENGTHD(18) = 3/4" NPT BUSHING WELDED AT 18" INSERTION LENGTH
7-50 = 3/4" SCH. 40 INCONEL 601 PROTECTION TUBE
1.049"
0.840"
1. SCH. 40 PIPE ALLOY AND SIZE
0.540"
0.840"
1.050"
1.050"
ID
0.622"
OD
6-25
6-100
6-75
6-50
5-50
5-75
CODE
CARBON STEEL
CARBON STEEL
CARBON STEEL
CARBON STEEL
MATERIAL
446 SS
446 SS 1/2"
3/4"
1/2"
1/2"
3/4"
NPT
0.824"
0.364"
0.622"
0.824"
7-100 INCONEL 601
316 SS
316 SS
316 SS
8-75
8-50
8-25
7-75
7-50
INCONEL 601
INCONEL 601
1.049" 1.315" 1"
1.050"
0.840"
0.824"
0.364"
0.622" 1/2"
1/2"
1.050"
0.840"
0.824"
0.622"
3/4"
1/2"
SILICONE NITRIDE
LT-1 METAL CERAMIC
CAST IRON
12-75
13-75
15-75
14-75
HEXOLOY
REFRACTORY COATED
11-75
3/4"0.625" 1.625"
1.500"
0.750"
1.125"
0.500"
0.493"
0.625"
3/4"
3/4"
3/4"
0.840"1.049" 1"
1.050"
1.315"
3/4"
1"
2. OVERALL PIPE LENGTH
36
24
30
06
12
18
CODE
36.0" OVERALL LENGTH
30.0" OVERALL LENGTH
24.0" OVERALL LENGTH
LENGTH
18.0" OVERALL LENGTH
6.0" OVERALL LENGTH
12.0" OVERALL LENGTH
SPECIFY OTHER LENGTHXX
METAL PROTECTION TUBES
C-8
EXAMPLE PART NUMBER: 7-50-24-D(18)
16-75 VESUVIUS 0.824" 2.000" 3/4"
1" NPT WELDED STEEL BUSHINGE(X)
TO PROTECTION TUBE
STAINLESS STEEL BUSHING
PROTECTICE WHITE EPOXY COATING ON HEAD
CSA APPROVED EXPLOSION PROOF HEAD
TO PROTECTION TUBE
SS UNION AND NIPPLES TO CONNECT HEAD
X
W
V
SS
STEEL UNION AND NIPPLES TO CONNECT HEAD
SEPCIAL LIMITS OF ERROR
THERMOCOUPLE INSULATED FROM TUBE
CAST ALUMINUM WEATHERPROOF HEAD
(ONLY ON 0.50", 0.75" AND 1.0" SIZE PIPES)
(ONLY ON 0.50" AND 0.75" SIZE PIPES)
1 1/8" NPT WELDED STEEL BUSHING
(ONLY ON 0.50", 0.75" AND 1.0" SIZE PIPES)
1 1/2" NPT WELDED STEEL BUSHING
ADJUSTABLE STEEL FLANGE
P
M
K
L
H
G(X)
F(X)
OTHER (SPECIFY)
OPEN END (CLOSED END STANDARD)
INTERNAL GROUND SCREW IN HEAD
(ONLY ON 0.25" SIZE PIPES)
3/4" NPT WELDED STEEL BUSHING
(ONLY ON 0.50" SIZE PIPES)
1/2" NPT WELDED STEEL BUSHING
4. OPTIONS
AA
D(X)
C(X)
B
A
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
STRAIGHT THERMOCOUPLE ASSEMBLIESWITH METAL PROTECTION TUBES
SUPPLIED WITH CAST IRON HEADUNLESS OTHERWISE SPECIFIED
OVERALL LENGTH
INSERTION LENGTH ("X")
C-9
OPTION C THROUGH G
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Acrolab's straight metal protection tube thermocouple assemblies are designedfor a wide variety of medium to high temperature, corrosive and non corrosiveindustrial applications. Various pipe diameters and lengths are available as wellas many options for mounting, etc...
C-10
2 4- - 5
WITH METAL PROTECTION TUBESSTRAIGHT THERMOCOUPLE ASSEMBLIES
(ONLY ON 0.25" SIZE PIPES)
(ONLY ON 0.50" AND 0.75" SIZE PIPES)
3/4" NPT WELDED STEEL BUSHING
1" NPT WELDED STEEL BUSHING
1 1/8" NPT WELDED STEEL BUSHING
THERMOCOUPLE INSULATED FROM TUBE
CAST ALUMINUM WEATHERPROOF HEAD
1 1/2" NPT WELDED STEEL BUSHING
(ONLY ON 0.50", 0.75" AND 1.0" SIZE PIPES)
STEEL UNION AND NIPPLES TO CONNECT HEAD
(ONLY ON 0.50", 0.75" AND 1.0" SIZE PIPES)
PROTECTICE WHITE EPOXY COATING ON HEAD
CSA APPROVED EXPLOSION PROOF HEAD
SS UNION AND NIPPLES TO CONNECT HEAD
SILICONE NITRIDE
REFRACTORY COATED
4. OVERALL PIPE LENGTH
LT-1 METAL CERAMIC12-75
CODE
16-75
15-75
13-75
14-75
8-50
11-75
8-75
8-25
7-100
6-100
7-75
7-50
6-75
6-50
3/4"1.625"0.625"
LENGTH
0.493"
0.625"
0.500"
0.824"VESUVIUS
HEXOLOY
2.000"
0.750"
3/4"
3/4"
1.125"
1.500"
3/4"
3/4"
TO PROTECTION TUBE
X
W
V
SS
P
M
STAINLESS STEEL BUSHING
SEPCIAL LIMITS OF ERROR
TO PROTECTION TUBE
1.049"
0.364"
0.824"
1.049"
0.622"316 SS
CAST IRON
316 SS
INCONEL 601
316 SS
1/2"1.050"
0.840"
1.050"
1"
3/4"
0.840"
1.315"
1/2"
1"
0.622"
0.824"
0.622"
0.824"
1.049"CARBON STEEL
INCONEL 601
INCONEL 601
CARBON STEEL
CARBON STEEL
1"1.315"
1.050"
0.840"
3/4"
1/2"
1.050"
0.840"
3/4"
1/2"
K
L
H
G(X)
ADJUSTABLE STEEL FLANGE
E(X)
F(X)
D(X)
(ONLY ON 0.50" SIZE PIPES)
OPEN END (CLOSED END STANDARD)
INTERNAL GROUND SCREW IN HEAD
1/2" NPT WELDED STEEL BUSHING
3. SCH. 40 PIPE ALLOY AND SIZE
5-50
5-75
6-25
CODE
0.364"
0.824"
0.622"446 SS
CARBON STEEL
446 SS
MATERIAL ID
1/2"0.840"
1.050"
0.540"
3/4"
1/2"
OD NPT
AA
C(X)
B
A
OTHER (SPECIFY)
06 6.0" OVERALL LENGTH
12.0" OVERALL LENGTH
18.0" OVERALL LENGTH
30.0" OVERALL LENGTH
24.0" OVERALL LENGTH
SPECIFY OTHER LENGTH
36.0" OVERALL LENGTH36
XX
30
24
12
18TYPE N, SINGLE
TYPE K DUAL
TYPE J, DUALJJ
KK
DESCRIPTION
1. CALIBRATION
TYPE J, SINGLE
TYPE K, SINGLE
CODE
J
K
TYPE NN, DUAL
1
5. OPTIONS
K = CAST ALUMINUM WEATHERPROOF HEAD
EXAMPLE PART NUMBER: K8-7-50-024-KK8 = TYPE K, 8 GAUGE7-50 = INCONEL 601 PROTECTION TUBE, 1/2" PIPE024 = 24" LONG
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
COMPLETE ORDERNUMBER
2. WIRE GAUGE
8
11
14
CODE DESCRIPTION
14 GAUGE (J, K AND N ONLY)
11 GAUGE (J AND K ONLY)
8 GAUGE (J, K AND N ONLY)
3
N
NN
-
SUPPLIED WITH CAST IRON HEAD
UNLESS OTHERWISE SPECIFIED
HO
T L
EG
LEN
GTH
"X"
DIM
EN
SIO
N
COLD LEG LENGTH
90
C-11
ANGLE THERMOCOUPLE ASSEMBLIESWITH METAL PROTECTION TUBES
OPTION C THROUGH G
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Angle thermocouples are designed for over-the-side temperature measurement. Variousprotection tube materials are available as well as the common thermocouple calibrations.A variety of mounting options as well as terminations are available.
C-12
ANGLE THERMOCOUPLE ASSEMBLIESWITH METAL PROTECTION TUBES
SPECIFY OTHER LENGTHXXRR TYPE R, DUAL
L THERMOCOUPLE INSULATED FROM TUBE
7-50 = INCONEL 601 PROTECTION TUBE, 1/2" PIPE
EXAMPLE PART NUMBER: K8-7-50-024-012-K
3/4"
3/4"
3/4"
3/4"
3/4"
024 = 24" LONG HOT LEG024 = 12" LONG COLD LEG
K8 = TYPE K, 8 GAUGE
LT-1 METAL CERAMIC
REFRACTORY COATED14-75
16-75
15-75
VESUVIUS
HEXOLOY
SILICONE NITRIDE13-75
12-75
0.493" 1.500"
0.750"
2.000"0.824"
0.500"
1.125"
1.625"
0.625"
0.625"
SS UNION AND NIPPLES TO CONNECT HEAD
CSA APPROVED EXPLOSION PROOF HEAD
STEEL UNION AND NIPPLES TO CONNECT HEAD
PROTECTICE WHITE EPOXY COATING ON HEAD
TO PROTECTION TUBE
W
X
TO PROTECTION TUBE
STAINLESS STEEL BUSHING
SEPCIAL LIMITS OF ERROR
SS
V
P
M
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
1/2"
3/4"
1/2"
0.364" 0.540"6-25 CARBON STEEL
6-100
0.824" 1.050"7-75 INCONEL 601
316 SS8-50
8-75
11-75
316 SS
CAST IRON
INCONEL 601
8-25
7-100
316 SS
0.622" 1.050"
1.050"
0.840"
0.824"
1.049" 1"
1.315"
0.840"0.364"
1.049" 1"
INCONEL 601
CARBON STEEL
7-50
CARBON STEEL
CARBON STEEL6-75
6-50
0.840"
1.315"
0.622"
1.049" 1"
0.840"
1.050"0.824"
0.622"
2. SCH. 40 PIPE ALLOY AND SIZE
5-75
5-50
446 SS
446 SS
CODE MATERIAL
0.840"
1.050"0.824"
0.622"
ID OD NPT
TYPE S, DUALSS
(ONLY ON 0.50" AND 0.75" SIZE PIPES)
(ONLY ON 0.50", 0.75" AND 1.0" SIZE PIPES)
CAST ALUMINUM WEATHERPROOF HEAD
(ONLY ON 0.50", 0.75" AND 1.0" SIZE PIPES)
F(X) 1 1/8" NPT WELDED STEEL BUSHING
1 1/2" NPT WELDED STEEL BUSHING
ADJUSTABLE STEEL FLANGE
K
H
G(X)
(ONLY ON 0.50" SIZE PIPES)
1" NPT WELDED STEEL BUSHING
3/4" NPT WELDED STEEL BUSHING
(ONLY ON 0.25" SIZE PIPES)
E(X)
D(X)
OPEN END (CLOSED END STANDARD)
INTERNAL GROUND SCREW IN HEAD
5. OPTIONS
OTHER (SPECIFY)
1/2" NPT WELDED STEEL BUSHING
B
C(X)
AA
A
-
CODE
1. CALIBRATION
K TYPE K, SINGLE
TYPE K DUAL
TYPE J, DUAL
KK
JJ
TYPE R, SINGLE
TYPE S, DUAL
R
S
DESCRIPTION
TYPE J, SINGLEJ
1 2
12.0" OVERALL LENGTH12
36
30
18
24
36.0" OVERALL LENGTH
30.0" OVERALL LENGTH
24.0" OVERALL LENGTH
18.0" OVERALL LENGTH
3. HOT LEG LENGTH
06
CODE LENGTH
6.0" OVERALL LENGTH
-3 4
12.0" OVERALL LENGTH
LENGTH
6.0" OVERALL LENGTH
SPECIFY OTHER LENGTH
36.0" OVERALL LENGTH
30.0" OVERALL LENGTH
24.0" OVERALL LENGTH
18.0" OVERALL LENGTH
4. COLD LEG LENGTH
18
30
24
36
XX
06
12
CODE
- 5
K = CAST ALUMINUM WEATHERPROOF HEADAcrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
COMPLETE ORDERNUMBER
C-13
STRAIGHT CERAMIC PROTECTION TUBES
Plain
Collar
Nipple
Hex Fitting
The mullite and alumina protection tubes found on these pages are directreplacements for Acrolab's ceramic protection tube thermocouple assemblies.They are available in a wide variety of lengths and diameters and have thesame mounting options as the complete assemblies do.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
COMPLETE ORDER
EXAMPLE PART NUMBER: 16CH-024
16C1 = 1/2" ID X 11/16" OD MULLITE TUBEWITH 1" LONG STEEL NIPPLE
024 = 24" OVERALL LENGTH
C-14
1 2 3
STRAIGHT CERAMIC PROTECTION TUBES
2. TUBE "X" LENGTH
12
18
24
30
36
48
3. OPTIONS
8
NT
316 SS NIPPLE OR HEX TUBE FITTING
CODE DESCRIPTION
NO PROCESS MTG.THREADS ON PIPE NIPPLE
CODE DESCRIPTION12" OVERALL LENGTH
18" OVERALL LENGTH
24" OVERALL LENGTH
30" OVERALL LENGTH
36" OVERALL LENGTH
48" OVERALL LENGTH
SPECIFY OTHER LENGTHS IN1" INCREMENTS
NUMBER
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
1. TUBE MATERIAL
MULLITE
16AH
16A1
16A4
16A(X)
16A
CODE
16AC
TUBE SIZEID OD
16AF
FITTING SIZEPROCESS THREAD
FITTING TYPEDESCRIPTIONALUMINA
17AH
17A1
17A4
17A(X)
17A
17AF
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2" NPT
1/2" NPT
1/2" NPT
1/2" NPT
NONE
NONE
NONE
STEEL HEX. FITTING
1" LONG NIPPLE
4" LONG NIPPLE
(X)" LONG NIPPLE (SPECIFY)
7/8" OD X 2" BRASS FERRULE
PLAIN TUBE
5/8" OD X 1/2" LONG COLLAR
16BH
16B1
16B4
16B(X)
16B
16BC
16BF
17BH
17B1
17B4
17B(X)
17B
17AB
7/16" 11/16" 3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
NONE
NONE
NONE
STEEL HEX. FITTING
1" LONG NIPPLE
4" LONG NIPPLE
(X)" LONG NIPPLE (SPECIFY)
7/8" OD X 2" BRASS FERRULE
PLAIN TUBE
1" OD X 1/2" LONG COLLAR
16CH
16C1
16C4
16C(X)
16CC
16C
17CH
17C1
17C4
17C(X)
17C
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
NONE
NONE
STEEL HEX. FITTING
1" LONG NIPPLE
4" LONG NIPPLE
(X)" LONG NIPPLE (SPECIFY)
PLAIN TUBE
1 1/8" OD X 1/2" LONG COLLAR
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
16DH 17DH 5/8" 7/8" 1" NPT STEEL HEX. FITTING
16D1 17D1 1" LONG NIPPLE5/8" 7/8" 1" NPT
16D(X) 17D(X) (X)" LONG NIPPLE (SPECIFY)5/8" 7/8" 1" NPT
16D 17D NONE PLAIN TUBE5/8" 7/8"
16EH 17EH 1" 1 1/4" 1 1/4" NPT STEEL HEX. FITTING
16E1 17E1 1" LONG NIPPLE1" 1 1/4" 1 1/4" NPT
16E(X) 17E(X) (X)" LONG NIPPLE (SPECIFY)1" 1 1/4" 1 1/4" NPT
16E 17E NONE PLAIN TUBE1" NONE
18J-(X) 1 3/4" WITH COLLAR
18JC-(X) WITHOUT COLLAR1 3/4"
1"
1"
SILICON CARBIDE
Update No. 200803-01
C-15
"X"
"X"
"Y"
"X"
"Y"
STRAIGHT THERMOCOUPLE ASSEMBLIESWITH CERAMIC PROTECTION TUBES
HEX FITTING
PIPE NIPPLE WITH "H" OPTION
PIPE NIPPLE WITH "HF" OPTION
Acrolab's straight thermocouple assemblies with mullite or alumina protectiontubes are commonly used in high temperature process heating applications. Theyare available in a variety of lengths, diameters and mounting options.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
COMPLETE ORDER
C-16
1 4 5
STRAIGHT THERMOCOUPLE ASSEMBLIES
5. OPTIONS
A
B
OPEN END (CLOSED END STANDARD)
CODE DESCRIPTION
HEAD WITH INTERNAL GROUND SCREW
H
I
ADJUSTABLE STEEL FLANGE
OTHER (SPECIFY)
K WEATHERPROOF ALUMINUM HEAD
M SPECIAL LIMITS OF ERROR WIRE
P STEEL UNION AND NIPPLES TO CONNECT HEAD TO PROTECTION TUBE
V
W
STAINLESS STEEL UNION AND NIPPLES
PROTECTIVE WHITE EPOXY COATING ON HEAD
X EXPLOSION PROOF HEAD
WITH CERAMIC PROTECTION TUBES
HF THREADED FLANGE ON NIPPLE
4. TUBE "X" LENGTH
12
18
24
30
36
48
CODE DESCRIPTION12" OVERALL LENGTH
18" OVERALL LENGTH
24" OVERALL LENGTH
30" OVERALL LENGTH
36" OVERALL LENGTH
48" OVERALL LENGTH
SPECIFY OTHER LENGTHS IN1" INCREMENTS
NT NO PROCESS THREADS ON PIPE NIPPLE
NUMBER
EXAMPLE PART NUMBER: K14-16CI-018-K
K14 = TYPE K, 14 GAUGE16CI = MULLITE, 3/4" OD, 1" LONG NIPPLE018 = 18" INSERTIONK = WEATHERPROOF CAST ALUMINUM HEAD
2 3
1. CALIBRATION
B
K
N
R
S
BB
CODE DESCRIPTIONSINGLE, TYPE B
SINGLE, TYPE K
SINGLE, TYPE N
SINGLE, TYPE R
SINGLE, TYPE S
DUAL, TYPE B
KK
NN
DUAL, TYPE K
DUAL, TYPE N
2. GAUGE
8
11
14
CODE DESCRIPTIONTYPE K & N ONLY. 16C,
16D OR 16E TUBES ONLY
TYPE K ONLY. 16B, 16C,
16D OR 16E TUBES ONLY
TYPE N ONLY
24 TYPE B, R OR S ONLY
RR
SS
DUAL, TYPE R
DUAL, TYPE S
26 TYPE R OR S ONLY
3. TUBE MATERIAL
MULLITE
16AH
16A1
16A4
16A(X)
16A
CODE
16AC
TUBE SIZEID OD
16AF
FITTING SIZEPROCESS THREAD
FITTING TYPEDESCRIPTIONALUMINA
17AH
17A1
17A4
17A(X)
17A
17AF
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2" NPT
1/2" NPT
1/2" NPT
1/2" NPT
NONE
NONE
NONE
STEEL HEX. FITTING
1" LONG NIPPLE
4" LONG NIPPLE
(X)" LONG NIPPLE (SPECIFY)
7/8" OD X 2" BRASS FERRULE
PLAIN TUBE
5/8" OD X 1/2" LONG COLLAR
16BH
16B1
16B4
16B(X)
16B
16BC
16BF
17BH
17B1
17B4
17B(X)
17B
17AB
7/16" 11/16" 3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
NONE
NONE
NONE
STEEL HEX. FITTING
1" LONG NIPPLE
4" LONG NIPPLE
(X)" LONG NIPPLE (SPECIFY)
7/8" OD X 2" BRASS FERRULE
PLAIN TUBE
1" OD X 1/2" LONG COLLAR
16CH
16C1
16C4
16C(X)
16CC
16C
17CH
17C1
17C4
17C(X)
17C
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4" NPT
3/4" NPT
3/4" NPT
3/4" NPT
NONE
NONE
STEEL HEX. FITTING
1" LONG NIPPLE
4" LONG NIPPLE
(X)" LONG NIPPLE (SPECIFY)
PLAIN TUBE
1 1/8" OD X 1/2" LONG COLLAR
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
7/16" 11/16"
16DH 17DH 5/8" 7/8" 1" NPT STEEL HEX. FITTING
16D1 17D1 1" LONG NIPPLE5/8" 7/8" 1" NPT
16D(X) 17D(X) (X)" LONG NIPPLE (SPECIFY)5/8" 7/8" 1" NPT
16D 17D NONE PLAIN TUBE5/8" 7/8"
16EH 17EH 1" 1 1/4" 1 1/4" NPT STEEL HEX. FITTING
16E1 17E1 1" LONG NIPPLE1" 1 1/4" 1 1/4" NPT
16E(X) 17E(X) (X)" LONG NIPPLE (SPECIFY)1" 1 1/4" 1 1/4" NPT
16E 17E NONE PLAIN TUBE1" NONE
18J-(X) 1 3/4" WITH COLLAR
18JC-(X) WITHOUT COLLAR1 3/4"
1"
1"
SILICON CARBIDE
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com Update No. 200803-01
C-17
STRAIGHT THERMOCOUPLE ASSEMBLIESWITH DOUBLE PROTECTION TUBES
"X"
"X"
"X"
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Acrolab's double protection tube assemblies all come equipped with aceramic inner protection tube, and a variety of ceramic, metal alloy orcomposite material outer protection tube. They are used in a varietyof high temperature process heating applications.
OPTION J
OPTION T
OPTIONS E, F OR G
"U"
COMPLETE ORDERNUMBER
C-18
2 3 4
STRAIGHT THERMOCOUPLE ASSEMBLIESWITH DOUBLE PROTECTION TUBES
3. TUBE "X" LENGTH
12
18
24
30
36
48
CODE DESCRIPTION12" OVERALL LENGTH
18" OVERALL LENGTH
24" OVERALL LENGTH
30" OVERALL LENGTH
36" OVERALL LENGTH
48" OVERALL LENGTH
SPECIFY OTHER LENGTHS IN1" INCREMENTS
1
1. THERMOCOUPLE
R24
R26
S24
S26
B24
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
2. TYPE
16A1-16B1
16A1-16B4
16A1-16B(Y)
16A-16BH
16A-12-75
16B-7-75
CODE INNERMULLITE
MULLITE
MULLITE
MULLITE
MULLITE
MULLITE
17A1-17B1 ALUMINA
ALUMINA
ALUMINA
ALUMINA
ALUMINA
ALUMINA
17A1-17B4
17A1-17B(Y)
17A-17BH
17A-12-75
17BH-18J
OUTERMULLITE
MULLITE
MULLITE
MULLITE
LT-1
INCONEL 601
ALUMINA
ALUMINA
ALUMINA
ALUMINA
LT-1
SILICON CARBIDE
OD11/16"
11/16"
11/16"
11/16"
7/8"
1.050"
11/16"
11/16"
11/16"
11/16"
7/8"
1 3/4"
16BH-18J MULLITE SILICON CARBIDE 1 3/4"
MOUNTING FITTING TYPE & LENGTH3/4" NPT x 1 1/2" LONG NIPPLE
3/4" NPT x 4" LONG NIPPLE
3/4" NPT x (X") LONG NIPPLE
3/4" NPT x 1/2" NPT HEX. NIPPLE
NONE, OR TABLE 3 OPTIONS E, F OR G
NONE, OR TABLE 3 OPTIONS E, F, G OR H
3/4" NPT x 1 1/2" LONG NIPPLE
3/4" NPT x 4" LONG NIPPLE
3/4" NPT x (X") LONG NIPPLE
3/4" NPT x 1/2" NPT HEX. NIPPLE
NONE, OR TABLE 3 OPTIONS E, F OR G
NONE, OR TABLE 3 OPTIONS E, F, G OR H
NONE, OR TABLE 3 OPTIONS H, J OR T
4. OPTIONS
B
E
F
H
CODE DESCRIPTIONHEAD WITH INTERNAL GROUND SCREW
(X) 1" NPT WELDED STEEL BUSHING
(ONLY 0.75" SIZE TUBES)
(X) 1 1/4" NPT WELDED STEEL BUSHING
(ONLY 0.75" SIZE TUBES)
ADJUSTABLE STEEL FLANGE
I
J
K
M
N
G (X) 1 1/2" NPT WELDED STEEL BUSHING
P
SPECIAL CONSTRUCTION (DESCRIBE)
FIXED FLANGE
WEATHERPROOF HEAD - ALUMINUM
SPECIAL LIMITS OF ERROR
(FOR P-R RH T/C ONLY)
OPEN TYPE TERMINAL HEAD
HEAD TO PROTECTION TUBESTEEL UNION AND NIPPLES TO CONNECT
T
V
W
X
CLAMP ASSEMBLY
STAINLESS STEEL UNION AND NIPPLES
HEAD (2 mil.)
PROTECTIVE WHITE EPOXY COATING ON
EXPLOSION PROOF HEAD - CSA APPROVED
(ONLY 0.75" SIZE TUBES)
EXAMPLE PART NUMBER: S24-16A1-16B1-24-HS24 = TYPE S, 24 GAUGE16A1-16B1 = MULLITE INNER, MULLITE OUTER PROTECTION TUBE, 3/4" NPT X 1.5" LONG NIPPLE24 = 24" LONG PROTECTION TUBEH = ADJUSTABLE STEEL FLANGE
-+
J
INERTION LENGTH
INSERTION LENGTH
INSERTION LENGTH
INSERTION LENGTH
MgO THERMOCOUPLES
C-19
Acrlolab's Magnesium Oxide (MgO) thermocouples are manufactured using standard purity (96%) MagnesiumOxide mineral insulation in a fully annealed metal sheath. They are available in diameters of 0.032" to 3/8" ODand are extremely flexible. The following pages will aid you in selecting a MgO Thermocouple to suit yourapplication's needs.
option 16
option 03
option 32, 33, 35, 36
option 2, 22
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-20
MgO THERMOCOUPLES [1 to 4]
E28
J
K
K
E
J
N/A316 SS
INCONEL 600
316 SS
N/A E18 E48E38 E68
CALIBRATION
1. CALIBRATION, TUBE DIAMETER AND MATERIAL
0.032"MATERIAL
SINGLE ORDER CODE NUMBERS
0.040" 1/8"1/16" 3/8"1/4"3/16"
J008 J08 J18 J28 J38 J48 J58
K14N/A N/A K24 K34 K44 K64
J007 J07 J17 J27 J37 J47 J67
310SS
316 SS K18K08K008 K28 K38 K48 K68
K17
N/AK 446 SS N/AN/A
K INCONEL 600 K007 K07
N/A N/A K45 K65
K37K27 K67K47
N17N N/A N/A N27 N37 N47 N67INCONEL 600
T18T 316 SS N/A N/A T28 T38 T48 T68
KK28 KK38N/AN/AK 316 SS KK18
INCONEL 600
INCONEL 600
316 SST
N
446 SSK
K
N/AN/A
N/A N/A
TT38TT28TT18
NN27N/A NN37
N/A
N/A N/A
N/A
KK28KK17 KK38
N/AN/A N/A
INCONEL 600
K 310SS
J
E 316 SS
J 316 SS
N/A N/A
N/A N/A
KK34KK24N/A
JJ27JJ17 JJ37
N/AN/A
N/A N/A
EE38EE28EE18
JJ28JJ18 JJ38
KK48 KK68
TT68TT48
NN47 NN67
KK48 KK68
KK45 KK65
KK64KK44
JJ47 JJ67
EE68EE48
JJ48 JJ48
DUAL ORDER CODE NUMBERS
INSERT 3 DIGIT LENGTH IN INCHES
2. SHEATH LENGTH
CODE
3. HOT JUNCTION STYLE
E
G
U
DESCRIPTION
UNGROUNDED JUNCTION
GROUNDED JUNCTION
EXPOSED JUNCTION
T CLEAR TEFLON COATING ON SHEATH
4. SHEATH OPTIONS
DESCRIPTION
BLACK PVC COATING ON SHEATH
SPECIAL LIMITS OF ERROR
HIGH PURITY MgO (99.6% PURE)
P
M
CODE
H
61 2 43 - -5 -87- 9
5 TO 9: SEE PAGES C-21 TO C-28
ODODODOD OD OD OD
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-21
"X"
"X"
OPTIONS 02 TO 15, 19 AND 25 OPTION 14
OPTION 18 OPTION 20(X)
OPTIONS 21(X) TO 25(X)
MgO THERMOCOUPLES [5]
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
CODE DESCRIPTION
5. ELEMENT FITTING
1 - 2 - 3 4 -
NO ELEMENT MOUNTING FITTING00
01 1/8" NPT, STAINLESS STEEL FERRULE
02
12
STAINLESS STEEL, ONE TIME ADJUSTABLE
COMPRESSION FITTING
COMPRESSION FITTING
STAINLESS STEEL, ONE TIME ADJUSTABLE
FITTING TYPE
C-22
5 -
MgO THERMOCOUPLES [5]
1/2" NPT, STAINLESS STEEL FERRULE
STAINLESS STEEL, RE-ADJUSTABLE
STAINLESS STEEL, ONE TIME ADJUSTABLE
COMPRESSION FITTING
09
COMPRESSION FITTING
05
1/8" NPT, LAVA PACKING GLAND
1/4" NPT, STAINLESS STEEL FERRULE
STAINLESS STEEL, RE-ADJUSTABLE
COMPRESSION FITTING
1/8" NPT, TEFLON FERRULE
BRASS, ADJUSTABLE COMPRESSION15
FITTING
1/8" NPT, BRASS FERRULE
BRASS, ADJUSTABLE SPRING LOADED WELL19
FITTING
1/2" NPT, STAINLESS STEEL FERRULE
BRASS, ADJUSTABLE COMPRESSION25
FITTING
1/4" NPT, BRASS FERRULE
ADJUSTABLE STEEL FLANGE WITH BRASS14
COMPRESSION FITTING
3.5" OUTSIDE DIAMETER
304 STAINLESS STEEL WELD PAD18
(1" X 1" X 1/8" THICK STANDARD)
1/8" NPT, BRASS FERRULE
1/8" NPT, AVAILABLE FOR 1/16", 1/8",
FIXED STAINLESS STEEL BUSHING
(SPECIFY "X" DIMENSION)
24(X)
FIXED STAINLESS STEEL BUSHING
FIXED STAINLESS STEEL BUSHING
(SPECIFY "X" DIMENSION)
(SPECIFY "X" DIMENSION)
23(X)
21(X)
SPECIAL FITTING, DESCRIBEAA
AVAILABLE FOR 1/8" AND 3/16"
(SPECIFY "X" DIMENSION)
BAYONET CAP AND SPRING20(X)
DIAMETER SHEATHS
3/16" AND 1/4" OD SHEATHS ONLY
1/4" NPT, AVAILABLE FOR 1/16", 1/8",
3/16" AND 1/4" OD SHEATHS ONLY
1/2" NPT, AVAILABLE FOR 1/8", 3/16",
1/4" AND 3/8" OD SHEATHS
1/4" AND 3/8" OD SHEATHS
FIXED STAINLESS STEEL BUSHING
(SPECIFY "X" DIMENSION)
25(X) 3/4" NPT, AVAILABLE FOR 1/8", 3/16",
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-23
MgO THERMOCOUPLES [6]
OPTIONS 37 AND 38
OPTION 22
OPTION 02
OPTION 01
OPTION 03
J
+
-
SHEATH TERMINATIONS
PLUG AND JACK TERMINATIONS
OPTION 04
+
J
-
OPTION 05
-
OPTION 06
J
- -
OPTION 39
J
+
-
OPTION 40
J
J
OPTION 41
-
+
-
+-
OPTION 42
- -
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
SQUARED END01
3" STRIPPED LEADS22
02 1" STRIPPED LEADS
1/2" NPT STEEX HEX. FITTING
38
37
CODE
6A. SHEATH TERMINATIONS
DESCRIPTION
WITH 3" STRIPPED LEADS
FITTING WITH 3" STRIPPED LEADS1/2" NPT STAINELESS STEEX HEX.
6B. PLUG & JACK TERMINATIONS
CODE DESCRIPTION
STANDARD SIZE PLUG03
04
05
06
39STANDARD SIZE JACK1/16" THROUGH 1/4" OD SHEATHS ONLY
JACKMINIATURE SIZE PLUG WITH MATING
1/16" THROUGH 1/4" OD SHEATH ONLY
STANDARD SIZE PLUG WITH MATINGJACK
1/16" THROUGH 3/16" OD SHEATH ONLYMINIATURE SIZE PLUG
PLUGMINIATURE SIZE JACK WITH MATING
MINIATURE SIZE JACK1/16" THROUGH 1/4" SHEATH ONLY
PLUGSTANDARD SIZE JACK WITH MATING
42
41
40
C-24
SPECIAL FITTING (DESCRIBE)AA
-1 2 - 3 4 5- - -6
MgO THERMOCOUPLES [6]
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-25
MgO THERMOCOUPLES [6]
OPTION 17
HEAD TERMINATIONS
OPTIONS 31 TO 36
OPTIONS 20 AND 21
LEADWIRE TRANSITIONS
OPTION 15
OPTION 16
OPTION 15H
OPTION 19
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.comUpdate No. 200803-01
WITH 1/2" NPT STEEL HEX. FITTING
CAST IRON SCREW COVER HEAD
CAST IRON SCREW COVER HEAD
WITH 1/2" NPT SS HEX. FITTING
WITH 1/2" NPT SS HEX. FITTINGCAST ALUMINUM SCREW COVER HEAD
WITH 1/2" NPT STEEL HEX. FITTING
36
35
33
17
CAST ALUMINUM SCREW COVER HEAD
WITH NO PROCESS THREADCAST ALUMINUM SCREW COVER HEAD
CSA APPROVED EXPLOSION PROOF HEAD
21
31
32
20
6C. HEAD TERMINATIONSCODE DESCRIPTION
MINIATURE PLASTIC HEAD, 1/4" NPTPROCESS AND CONDUIT OPENEINGS
WITH 1/2" NPT STEEL HEX. FITTING
WITH 1/2" NPT SS HEX. FITTINGCSA APPROVED EXPLOSION PROOF HEAD
WITH NO PROCESS THREADCAST IRON SCREW COVER HEAD34
DESCRIPTIONCODE
6D. LEADWIRE TRANSITIONS
EXTENSION LEADWIRE TRANSITION15FITTING AND RELIEF SPRING
15HFITTINGHIGH TEMPERATURE TRANSITION
INLINE TRANSITION FITTING
FITTING SEALED WITH HEAT SHRINKEXTENSION LEADWIRE TRANSITION
16
19
SPECIAL TERMINATION (DESCRIBE)BB
TR HEAD MOUNTED TRANSMITTER(DETAILS TO BE GIVEN)
C-26
-1 2 - 43 6-- 5 -
MgO THERMOCOUPLES [6]
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-27
1
7. EXTENSION LEADWIRE
CODE DESCRIPTION
AVAILABLE
FIBERGLASS INSULATION - SOLID
TEMP.CALIBRATIONSRATING
CONDUCTOR* *** * 900 F
2CONDUCTOR - SS ARMOUR
FEP TEFLON INSULATION - STRANDED400 F
3CONDUCTOR
FIBERGLASS INSULATION - STRANDED
CONDUCTOR - SS ARMOUR4
HI-TEMP FIBERGLASS INSULATION - SOLID1300 F
900 F
CONDUCTOR
FEP TEFLON INSULATION - STRANDED5 900 F
6CONDUCTOR
CONDUCTOR - STAINLESS STEEL OVERBRAID
SPECIAL LEADWIRE, DESCRIBE
FIBERGLASS INSULATION - STRANDED
CONDUCTOR
SOLID CONDUCTOR
EXTREME HI-TEMP CERAMIC FIBER -
FIBERGLASS INSULATION - STRANDED8
CC
9
7
* *
POLYVINYL INSULATION - STRANDED221 F
900 F
900 F
2200 F
** * *
*
*** *
*
** * *
** **
* * * *
J K T E N
31 - -2 - 54 6 -- 7 -8
INSERT 3 DIGIT LENGTH IN INCHES
8. LEADWIRE LENGTH
MgO THERMOCOUPLES [7,8]
*
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-28
9. EXTENSION WIRE TERMINATIONS
LEADS NOT STRIPPED1
CODE DESCRIPTION
2 LEADS STRIPPED 4"
3 LEADS STRIPPED 4" WITH SPADE LUGS
4 STANDARD SIZE MALE PLUG
MINIATURE MALE PLUG WITH MATING FEMALE JACK7
8 12" SPLIT LEADS WITH 2" STRIPPED LEADS WITH SPADE LUGS AND
5
6 MINIATURE MALE PLUG
STANDARD SIZE MALE PLUG WITH MATING FEMALE JACK
9 STANDARD SIZE FEMALE JACK
11 MINIATURE FEMALE JACK
10 STANDARD SIZE FEMALE JACK WITH MATING MALE PLUG
1/2" BX CONNECTOR
12 MINIATURE FEMALE JACK WITH MATING MALE PLUG
13
1 2- -4- 3 -5 87-6 - 9
MgO THERMOCOUPLES [9]
STANDARD SIZE 3-PIN FEMALE JACK WITH MATING MALE PLUG
STANDARD SIZE 3-PIN MALE PLUG WITH MATING FEMALE JACK
STANDARD SIZE 3-PIN MALE PLUG
STANDARD SIZE 3-PIN FEMALE JACK
16
15
14
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
RESISTANCE TEMPERATURE DETECTORS
INSERTION LENGTH
INSERTION LENGTH
C-29
INERTION LENGTH
INSERTION LENGTH
J
+
-
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Acrolab's Resistance Temperature Detector's are available in the same styles as our thermocouples are.Standard accuracy is 0.3%, but are available in 0.01% for more accuracy. Standard temperature RTD'sare designed and built to be moisture resistant, where as high temperature RTD's generally are not.Acrolab's RTD's are built with a 316SS sheath as standard.
option 2, 22
option 32, 33, 35, 36
option 03
option 16
C-30
2. SHEATH LENGTH
INSERT 3 DIGIT LENGTH IN INCHES
1. CALIBRATION, TUBE DIAMETER AND MATERIAL
.03% 316 SS
ACCURACY MATERIAL
DUAL ORDER CODE NUMBERS
SINGLE ORDER CODE NUMBERS
RTD28 RTD38
1/8" 3/16"
RTD68RTD48
3/8"1/4"
RESISTANCE TEMPERATURE DETECTORS [1 to 3]
1
4 TO 8: SEE PAGES C-33 TO C-40
HIGH TEMP BULB (400F / 204C) ( 0.1% ACCURACY ONLY)
HIGH ACCURACY BULB ( 0.01% ACCURACY)
BLACK PVC COATING ON SHEATH
DESCRIPTION
CLEAR TEFLON COATING ON SHEATH
H
A
P
T
4. SHEATH AND OTHER OPTIONS
CODE
2 -3 -4 5 - 6 7 - 8
316 SS RTD/RTD48RTD/RTD28 RTD/RTD38 RTD/RTD68
AT 0 C
+-
- .03%+
+-
OD ODODOD
*RTDs COME STANDARD AS 3-WIRE (2 RED, 1 WHITE),2 AND 4 WIRE ARE AVAILABLE UPON REQUESTED
C FIRST RESPONSE COPPER SHEATH
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
C-31
OPTIONS 21(X) TO 25(X)
"X"
"X"
OPTION 18 OPTION 20(X)
OPTION 14OPTIONS 02 TO 15, 19 AND 25
RESISTANCE TEMPERATURE DETECTORS [4]
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
FIXED STAINLESS STEEL BUSHING
SPECIAL FITTING, DESCRIBE
FIXED STAINLESS STEEL BUSHING
FIXED STAINLESS STEEL BUSHING
FIXED STAINLESS STEEL BUSHING
(1" X 1" X 1/8" THICK STANDARD)
304 STAINLESS STEEL WELD PAD
ADJUSTABLE STEEL FLANGE WITH BRASS
BRASS, ADJUSTABLE COMPRESSION
BRASS, ADJUSTABLE SPRING LOADED WELL
BRASS, ADJUSTABLE COMPRESSION
STAINLESS STEEL, RE-ADJUSTABLE
STAINLESS STEEL, ONE TIME ADJUSTABLE
STAINLESS STEEL, RE-ADJUSTABLE
RESISTANCE TEMPERATURE DETECTORS [4]
FITTING TYPE
STAINLESS STEEL, ONE TIME ADJUSTABLE
STAINLESS STEEL, ONE TIME ADJUSTABLE
NO ELEMENT MOUNTING FITTING
09
AA
(SPECIFY "X" DIMENSION)
(SPECIFY "X" DIMENSION)
25(X)
24(X)
23(X)
(SPECIFY "X" DIMENSION)
(SPECIFY "X" DIMENSION)
20(X)
21(X)
25
BAYONET CAP AND SPRING
(SPECIFY "X" DIMENSION)
FITTING
15
19
18
FITTING
FITTING
14
12
COMPRESSION FITTING
COMPRESSION FITTING
COMPRESSION FITTING
COMPRESSION FITTING
05
02
COMPRESSION FITTING
COMPRESSION FITTING
5. ELEMENT FITTING
CODE
01
00
1/8" NPT, LAVA PACKING GLAND
1/4" AND 3/8" OD SHEATHS
C-32
3/4" NPT, AVAILABLE FOR 1/8", 3/16",
1/2" NPT, AVAILABLE FOR 1/8", 3/16",
1/4" NPT, AVAILABLE FOR 1/16", 1/8",
1/8" NPT, AVAILABLE FOR 1/16", 1/8",
3/16" AND 1/4" OD SHEATHS ONLY
1/4" AND 3/8" OD SHEATHS
3/16" AND 1/4" OD SHEATHS ONLY
DIAMETER SHEATHS
AVAILABLE FOR 1/8" AND 3/16"
1/4" NPT, BRASS FERRULE
1/8" NPT, BRASS FERRULE
1/8" NPT, BRASS FERRULE
1/2" NPT, STAINLESS STEEL FERRULE
3.5" OUTSIDE DIAMETER
1/8" NPT, TEFLON FERRULE
1/4" NPT, STAINLESS STEEL FERRULE
1/2" NPT, STAINLESS STEEL FERRULE
1/8" NPT, STAINLESS STEEL FERRULE
DESCRIPTION
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
-21 3 4
C-33
RESISTANCE TEMPERATURE DETECTORS [4]
OPTION 41
OPTION 42
OPTION 40
OPTION 39
OPTION 06
OPTION 05
OPTION 04
OPTION 03
PLUG AND JACK TERMINATIONS
OPTIONS 37 AND 38
OPTION 22
OPTION 02
OPTION 01
SHEATH TERMINATIONS
-
+G
UU
U
-
G
U
+
G
U
-
+
UG
+
U
G
U
G
-
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
WITH 3" STRIPPED LEADS
SPECIAL FITTING (DESCRIBE)AA
C-34
MINIATURE SIZE PLUG WITH MATING
STANDARD SIZE JACK WITH MATING
1/16" THROUGH 1/4" SHEATH ONLYMINIATURE SIZE JACK
1/16" THROUGH 1/4" OD SHEATHS ONLYSTANDARD SIZE JACK
6B. PLUG & JACK TERMINATIONS
MINIATURE SIZE PLUG1/16" THROUGH 3/16" OD SHEATH ONLY
STANDARD SIZE PLUG WITH MATING
1/16" THROUGH 1/4" OD SHEATH ONLYSTANDARD SIZE PLUG
DESCRIPTION
MINIATURE SIZE JACK WITH MATING
FITTING WITH 3" STRIPPED LEADS1/2" NPT STAINELESS STEEX HEX.
05
41
42
40
PLUG
PLUG
39
06 JACK
CODE
04
03
JACK
38
RESISTANCE TEMPERATURE DETECTORS [4]
6A. SHEATH TERMINATIONS
1" STRIPPED LEADS
3" STRIPPED LEADS
1/2" NPT STEEX HEX. FITTING
DESCRIPTION
22
37
02
CODE
01 SQUARED END
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
21 -3 -4
C-35
RESISTANCE TEMPERATURE DETECTORS [5]
OPTIONS 20 AND 21
OPTION 15H
OPTION 19
OPTION 16
OPTIONS 31 TO 36
OPTION 15
LEADWIRE TRANSITIONS
OPTION 17
HEAD TERMINATIONS
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.comUpdate No. 200803-01
WITH NO PROCESS THREAD
EXTENSION LEADWIRE TRANSITION
EXTENSION LEADWIRE TRANSITION
FITTING SEALED WITH HEAT SHRINK
WITH 1/2" NPT STEEL HEX. FITTING
WITH 1/2" NPT STEEL HEX. FITTING
CAST ALUMINUM SCREW COVER HEAD
CAST ALUMINUM SCREW COVER HEAD
19
BB
INLINE TRANSITION FITTING
SPECIAL TERMINATION (DESCRIBE)
HEAD MOUNTED TRANSMITTER
16
15
CODE
15H
6D. LEADWIRE TRANSITIONS
TR
FITTING AND RELIEF SPRING
HIGH TEMPERATURE TRANSITIONFITTING
DESCRIPTION
(DETAILS TO BE GIVEN)
35
36
34
33
32
CAST IRON SCREW COVER HEAD
CAST IRON SCREW COVER HEAD
CAST IRON SCREW COVER HEAD
WITH NO PROCESS THREAD
WITH 1/2" NPT SS HEX. FITTING
WITH 1/2" NPT SS HEX. FITTING
C-36
RESISTANCE TEMPERATURE DETECTORS [5]
PROCESS AND CONDUIT OPENEINGS
WITH 1/2" NPT STEEL HEX. FITTING
MINIATURE PLASTIC HEAD, 1/4" NPT
CSA APPROVED EXPLOSION PROOF HEAD
CSA APPROVED EXPLOSION PROOF HEAD
CAST ALUMINUM SCREW COVER HEAD
HEAD TERMINATIONS
21
20
17
CODE
6C. SHEATH TERMINATIONS
31
WITH 1/2" NPT SS HEX. FITTING
DESCRIPTION
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
21 -3 -4 -5
C-37
FIBERGLASS INSULATION - STRANDED
FEP TEFLON INSULATION - STRANDED
FIBERGLASS INSULATION - STRANDED
CONDUCTOR - STAINLESS STEEL OVERBRAID
FIBERGLASS INSULATION - STRANDED
8. LEADWIRE LENGTH
INSERT 3 DIGIT LENGTH IN INCHES
SPECIAL LEADWIRE, DESCRIBECC
9
CONDUCTOR8
CONDUCTOR - SS ARMOUR
CONDUCTOR5
4
900 F
900 F
900 F
900 F
RESISTANCE TEMPERATURE DETECTORS [6, 7]
DESCRIPTION
FEP TEFLON INSULATION - STRANDED
CONDUCTOR - SS ARMOUR2
7. EXTENSION LEADWIRE
CODERATING
400 F
TEMP.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
1 2 543 - - 6- -7
CODE
7 MINIATURE MALE PLUG WITH MATING FEMALE JACK
C-38
STANDARD SIZE 3-PIN FEMALE JACK WITH MATING MALE PLUG
STANDARD SIZE 3-PIN MALE PLUG WITH MATING FEMALE JACK
12" SPLIT LEADS WITH 2" STRIPPED LEADS WITH SPADE LUGS AND
STANDARD SIZE 3-PIN MALE PLUG
STANDARD SIZE 3-PIN FEMALE JACK
13
12
11
1/2" BX CONNECTOR
STANDARD SIZE FEMALE JACK
10
9
8
STANDARD SIZE MALE PLUG WITH MATING FEMALE JACK
LEADS STRIPPED 4" WITH SPADE LUGS
2
MINIATURE MALE PLUG
STANDARD SIZE MALE PLUG
6
5
4
3
LEADS STRIPPED 4"
DESCRIPTION
LEADS NOT STRIPPED
5. EXTENSION WIRE TERMINATIONS
1
RESISTANCE TEMPERATURE DETECTORS [8]
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
21 -3 -4 -5 76 - 8
TUBESKIN THERMOCOUPLE ASSEMBLIES
1 = WELD PAD OPTION
06, 07, 09, 10 SHEATH TERMINATION OPTIONS
C-39
02 SHEATH TERMINATION OPTION
Acrolab's Tubeskin Thermocouples are designed to be welded directly to boiler pipesand the like. They are manufactured using a felxible Magnesium Oxide 316SS or310SS sheath. Various mounting devices and terminations are available. Acrolabhas the ability to provide you with countless custom designs and specificationsas well.
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
COMPLETE ORDER NUMBER
-
C-40
3 4 5 76B --1A 6A2 -1B
EXAMPLE PART NUMBER:K44168G-1-04-1B048-1
168 = 168" OVERALL SHEATH LENGTHG = GROUNDED JUNCTION1 = 1/8" THICK X 1" X 1" 310 SS WELD PAD
K44 = TYPE K, 1/4" OD, 310 SS
TYPE J CALIBRATION
1A. CALIBRATION
TYPE K CALIBRATION
J
K
CODE DESCRIPTION
1B. SHEATH DIAMETER
34
24
CODE
1/8" OD, 310 SS
3/16" OD, 316 SS
DESCRIPTION
64
44 1/4" OD, 310 SS
3/8" OD, 310 SS
2. SHEATH DIAMETERXXX SHEATH LENGTH (IN INCHES)
3. JUNCTION TYPE
U
G
CODE
GROUNDED
UNGROUNDED
DESCRIPTION
1
0
1" X 1", 310 SS
ROUNDED WELDED TIP
WELD PAD, 1/8" THICK,
4. SHEATH TIP STYLECODE DESCRIPTION
5. SHEATH TERMINATION
01
00
CODE
NOT APPLICABLE
LEADS STRIPPED 4.0"
DESCRIPTION
TRANSITION FITTING WITH RELIEF SPRING
TRANSITION FITTING
03
02
1/2" NPT SS HEX. NIPPLE, WITH CAST ALUMINUM HEAD
1/2" NPT SS HEX. NIPPLE, WITH CAST IRON HEAD
3/4" NPT SS HEX. NIPPLE, WITH 4" STRIPPED LEADS
1/2" NPT SS HEX. NIPPLE, WITH 4" STRIPPED LEADS
06
07
05
04
3/4" NPT SS HEX. NIPPLE, WITH EXPLOSION PROOF HEAD
3/4" NPT SS HEX. NIPPLE, WITH CAST IRON HEAD
3/4" NPT SS HEX. NIPPLE, WITH CAST ALUMINUM HEAD
1/2" NPT SS HEX. NIPPLE, WITH EXPLOSION PROOF HEAD
11
10
09
08
FIBERGLASS, STRANDED, WITH SS ARMOUR
FIBERGLASS, STRANDED, WITH SSOB
FIBERGLASS, STRANDED
6A. EXTENSION LEADWIRE TYPE
4C
4B
3B
4A
3C
3A
2C
1C
2A
2B
1B
1A
CODE DESCRIPTION
TEFLON, STRANDED, WITH SS ARMOUR
TEFLON, STRANDED, WITH SSOB
TEFLON, STRANDED
FIBERGLASS, SOLID, WITH SS ARMOUR
FIBERGLASS, SOLID, WITH SSOB
FIBERGLASS, SOLID
TEFLON, SOLID, WITH SS ARMOUR
TEFLON, SOLID, WITH SSOB
TEFLON, SOLID
6B. LEADWIRE LENGTHXXX SHEATH LENGTH (IN INCHES)
CODE
7. LEADWIRE TERMINATION
3
6
8
7
5
4
0
2
1
MINIATURE FEMALE JACK
MINIATURE FEMALE PLUG
STANDARD MALE JACK
STANDARD MALE PLUG
LEADS STRIPPED 4.0" WITH SPADE LUGS AND BX CONNECTOR
DESCRIPTION
LEADS STRIPPED 4.0" WITH BX CONNECOTR
NOTHING
LEADS STRIPPED 4.0"
LEADS STRIPPED 4.0" WITH SPADE LUGS
1 = STRIPPED LEADS, 4.0"1B048 = FIBERGLASS LEADS WITH SSOB, 48" LONG04 = TRANSITION FITTING
TUBESKIN THERMOCOUPLE ASSEMBLIES
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Thermal Manufacturing Solutions
Section D Food, Dairy and Pharmaceutical
Thermocouples and RTDs
Food and Meat Processing Thermocouples Sanitary Connected Thermocouples Food and Meat Processing RTDs Sanitary Connected RTDs Sanitary Fitting Styles
D-1 D-3 D-5 D-7 D-9
D-1
"X" DIMENSION
FOOD AND MEAT PROCESSING THERMOCOUPLES
4.0""E" DIMENSION
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Penetration style Thermocouples are designed to be used to measure internal temperatureof dough, fish, meat, poultry and other food products. They can also be used to measuretemperatures of other soft materials such as plastic or rubber. All meterials used in theconstruction of Acrolab's penetration style Thermcouples are FDA compliant for use insanitary applications. The sheaths are manufactured from 304SS hypodermic tubing witha sharp tip.
DIMENSIONS IN INCHESXX
* AVAILABLE WITH 0.180" OD SHEATH ONLY
3. "X" DIMENSION
2. DIAMETER
KKMP*
CODE
29
39
CODE
TTMP*
TMP
JJMP*
DESCRIPTION
0.134" OD
0.180" OD
DESCRIPTION
DUAL TYPE J
DUAL TYPE T
DUAL TYPE J
SINGLE TYPE T
24 = 24" "E" DIMENSION5 = MINIATURE PLUG
D-2
BB OTHER (DESCRIBE)
EXAMPLE PART NUMBER
8 = 8" "X" DIMENSION29 = 0.134" OD SHEATHJMP = TYPE J, SINGLE
JMP-29-08-24-5
LEADS - STRIPPED 2" WITH SPADE LUGS
DESCRIPTION
LEADS - TINNED 1/2", STRIPPED 2"
UNGROUNDED
3
STANDARD PLUG
MINIATURE PLUG5
U
4
5. OPTIONSCODE
2
FOOD AND MEAT PROCESSING THERMOCOUPLES
1. CALIBRATION
JMP
KMP
CODE CALIBRATION
SINGLE TYPE J
SINGLE TYPE K
1 - 2 - 3 -
DESCRIPTION
DIMENSIONS IN INCHES
4. "E" DIMENSION
XX
CODE
4 - 5
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.comUpdate No. 200803-01
D-3
0.840" OD 304SSSUPPORT TUBE
1/4" OD 316SS
304SS
REDUCED TIP1.25"
3/8" OD 316SS
"X"
1/4" OD 316SS
3.0"
SANITARY CONNECTED THERMOCOUPLES
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
are 316SS and come with a FDA compliant white thermoplastic head. The assembliescommon sanitary caps in the industry and all meet 3-A Sanitary Standard 74-. The sheathschemical, dairy, food and pharmaceutical processing industries. Acrolab offers the mostClean in place (CIP) style sanitary connected Thermocouples are used in the bevarage,
provide excellent washdown protection. Reduced tips are offered for faster responce time.
AUTHORIZED74-
D-4
2
OTHER (SPECIFY)
DESCRIPTION
OTHER (DESCRIBE)
16AI-14I CAP **
3A4 ADAPTOR *
16A CAP - BEVEL SEAT WITH 13-H NUT *
16 AMP CAP - TRI CLAMP
DESCRIPTION
OTHER (SPECIFY)
DUAL TYPE K
DUAL TYPE E
DUAL TYPE T
CODE
XX
05
65
55
04
2. LENGTH
TTSC
EESC
KKSC
CODE5"
5 1/2"
6 1/2"
4"
6
8
7
16A CAP - BEVEL SEAT *
2
5
1
4. SANITARY CAP STYLE
CALIBRATION
SINGLE TYPE J
SINGLE TYPE K
SINGLE TYPE E
SINGLE TYPE T
DUAL TYPE J
1. CALIBRATION
TSC
JJSC
ESC
KSC
JSC
CODE
3. SANITARY CAP SIZE
5
4
3
2
3"
2 1/2"
2"
1
CODE
1 1/2"
DESCRIPTION
1 -
RD REDUCED TIP
UNGROUNDED JUNCTION (T/C ONLY)
WHITE EPOXY COATING ON HEAD
WIRE SEAL SECURITY SCREWS
STAINLESS STEEL TAGS
HEAD MOUNTED TRANSMITTER
W
WS
U
ST
TR
WHITE POLYPROPYLENE HEAD
GROUNDED JUNTION (T/C ONLY)
WHITE EPOXY COATED ALUMINUM HEAD
NO HEAD, 6" TEFLON LEADS
SPRING LOADED T/C OR RTD
PP
G
R
EP
22
CODE
5. OPTIONSDESCRIPTION
- 3 4- - 5
SANITARY CONNECTED THERMOCOUPLES
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
AUTHORIZED74-
316L STAINLESS STEAL HEADSH
Update No. 200803-01
* MUST BE MANUALLY CLEANED
** NOT 3A AUTHORIZED
FOOD AND MEAT PROCESSING RTDs
"X" DIMENSION "E" DIMENSION 4.0"
D-5 Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
construction of Acrolab's penetration style RTD's are FDA compliant for use in sanitarytemperatures of other soft materials such as plastic or rubber. All meterials used in thedough, fish, meat, poultry and other food products. They can also be used to measure Penetration style RTD's are designed to be used to measure internal temperature of
applications. The sheaths are manufactured from 304SS hypodermic tubing with a sharptip. All assemblies come standard as a 3-wire construction and 0.12% accuracy at 0 C.
* AVAILABLE WITH 0.180" OD SHEATH ONLY
3. "X" DIMENSION
2. DIAMETER
CODE
XX
39
29
CODE
DIMENSIONS IN INCHES
DESCRIPTION
0.134" OD
0.180" OD
DESCRIPTION
24 = 24" "E" DIMENSION5 = MINIATURE PLUG
D-6
BB OTHER (DESCRIBE)
EXAMPLE PART NUMBER
8 = 8" "X" DIMENSION29 = 0.134" OD SHEATHRTD = 3-WIRE RTD, SINGLE
RTDMP-29-08-24-5
LEADS - STRIPPED 2" WITH SPADE LUGS
DESCRIPTION
LEADS - TINNED 1/2", STRIPPED 2"
3
STANDARD PLUG
MINIATURE PLUG5
4
5. OPTIONSCODE
2
FOOD AND MEAT PROCESSING RTDs
1. CALIBRATION
RTDMP*
RTD/RTDMP*
CODE CALIBRATION
SINGLE RTD, 100 ohm
DUAL RTD, 100 ohm
1 - 2 - 3 -
DESCRIPTION
DIMENSIONS IN INCHES
4. "E" DIMENSION
XX
CODE
4 - 5
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
SANITARY CONNECTED RTDs
"X" 3.0"
1/4" OD 316SS0.840" OD 304SSSUPPORT TUBE
304SS
REDUCED TIP1.25"
1/4" OD 316SS
3/8" OD 316SS
D-7
Clean in place (CIP) style sanitary connected RTD's are used in the bevarage, chemical,
provide excellent washdown protection. Reduced tips are offered for faster responce time.
sanitary caps in the industry and all meet 3-A Sanitary Standard 74-. The sheaths aredairy, food and pharmaceutical processing industries. Acrolab offers the most common
316SS and come with a FDA compliant white thermoplastic head. The assemblies
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
74-AUTHORIZED
D-8
SANITARY CONNECTED RTDs
DUAL 3-WIRE RTD
3-WIRE RTD
CALIBRATION
1. CALIBRATION
RTD/RTDSC
RTDSC
CODE
CODE
3. SANITARY CAP SIZE
2. LENGTH
4
5
2
3
1
04
65
XX
55
05
CODE
3"
OTHER (SPECIFY)
DESCRIPTION
1 1/2"
2"
2 1/2"
4"
5 1/2"
6 1/2"
OTHER (SPECIFY)
5"
DESCRIPTION
-1 -2 43 - - 5
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
AUTHORIZED74-
U UNGROUNDED JUNCTION (T/C ONLY)
DESCRIPTION
16A CAP - BEVEL SEAT WITH 13-H NUT *
WIRE SEAL SECURITY SCREWS
WHITE EPOXY COATING ON HEAD
1 16A CAP - BEVEL SEAT *
16AI-14I CAP **7
** NOT 3A AUTHORIZED
* MUST BE MANUALLY CLEANED
OTHER (DESCRIBE)8
3A4 ADAPTOR *
16 AMP CAP - TRI CLAMP5
6
2
4. SANITARY CAP STYLE
CODE
WS
W
316L STAINLESS STEAL HEAD
HEAD MOUNTED TRANSMITTER
STAINLESS STEEL TAGS
NO HEAD, 6" TEFLON LEADS
DESCRIPTION
SPRING LOADED T/C OR RTD
WHITE EPOXY COATED ALUMINUM HEAD
GROUNDED JUNTION (T/C ONLY)
WHITE POLYPROPYLENE HEAD
SH
TR
ST
G
PP
RD
R
REDUCED TIP
5. OPTIONSCODE
22
EP
Update No. 200803-01
SANITARY FITTING STYLES
- MUST BE MUNUALLY CLEANED
- CAP STYLE 16A (CODE No. 2 WITH NUT)
- CAP STYLE 16A (CODE No. 1 WITHOUT NUT)
- CAP STYLE 16APV - (CODE No. 3 WITHOUT NUT)
- CAP STYLE 16APV - (CODE No. 4 WITH NUT)
- CAP STYLE 16AI-14I (CODE No. 7)
- NOT 3-A AUTHORIZED
- CAP STYLE 16AMP (CODE No. 5)
- CAP STYLE 3A4 ADAPTOR (ORDER CODE No. 6)
- MUST BE MUNUALLY CLEANED
D-9 Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Thermal Manufacturing Solutions
Section E Explosion Proof Thermocouples and RTDs
Fixed Element RTD Assemblies Element Thermocouple Assemblies RTD Assemblies With Thermowells Thermocouple Assemblies With Thermowells Spring Loaded RTD Assemblies Spring Loaded Thermocouple Assemblies Temperature Transmitters for Explosion Proof Assemblies Connecting Head And Transmitter Selection Guide Overview Of NEC Hazardous Location Classifications And Methods Of Protection
E-1 E-3 E-5 E-7 E-9 E-11 E-13 E-14 E-15
EXPLOSION PROOF APPROVEDFIXED ELEMENT RTD ASSEMBLIES - MODEL 70-22
Explosion Proof Fixed Element RTD's are for use in U.S. and Canadian hazardous areas. They are designed to extinguish . ames inside the device eliminating the potential for ignition of ammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependent on connection head type, meet XP Class I, Division 1, Group A, B, C and D; DIP Class II, Division I, Groups E, F, G, and Class III, Division 1. They may be installed directly in the process without being inserted into a thermowell. The assemblies feature 316 stainless steel sheaths in various diameter sizes. They are available with or without process mountings and with aluminum or stainless steel explosion proof connection heads.
X
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.comE-1
FMAPPROVED
CSA FILE #217989
DESCRIPTION
1. AGENCY APPROVAL
RBF285L
LOW RANGE WIRE WOUND (-200 TO 204)C
R5T185L R5T285L
LOW RANGE THIN FILM (-40 to 204)C
RBF185L
SINGLE
R1T185L
DUPLEX
R1T285L
XP
CODE
FM/CSA explosion proofapproved assembly
1 2 3 4 65 7 98 Select Type and Range
CODE INITIAL ELEMENT ACCURACY 0C
2. 100 Ohm PLATINUM RTD ELEMENTS
0.1%
0.01%
RAF285L
HIGH RANGE WIRE WOUND (-200 TO 600)C
RAF185L
R1T285HR1T185H
0.12%
0.06%
0.1%
3. SHEATH DIAMETERS
CODE DIAMETER (inches)
or with 440 Series Transmitter)
4*
3
2
68
48
38
28* 1/8 *Not available in Duplex
3/8
1/4
3/16
DIAMETER (inches)CODE
4. ELEMENT CONNECTION
4 Wire Element *(Not Avail. in Duplex
3 Wire Element
2 Wire Element
8. HEAD TERMINATIONS
DESCRIPTION
Cast iron/aluminum explosion proof head Group C
DIN form B aluminum explosion proof head Group B72
75T-642B
74 DIN form B aluminum explosion proof head Group A
(4 to 20) mA HART Field Transmitter with aluminum
71
CODE
DIN form B 316 stainless steel explosion proof head Group B
316L stainless steel explosion proof head Group C
82
81
SB
I Stainless steel tag
1/2" NPT conduit reducer bushing
T-441**
T-440* (4 to 20) mA heat-mounted tranmitter
(4 to 20) mA isolated heat-mounted tranmitter
T-442**
*Only available with option 71 or 81
(4 to 20) mA HART isolated heat-mounted tranmitter
9. OPTIONS
explosion proof housing, Group A
**Not available with option 71 or 81
DESCRIPTIONCODE
8RNDC
9HP 1/2" NPT stainless steel bushing (no process threads)
3/4" x 1/2" NPT stainless steel hex nipple
7. HEAD MOUNTING FITTINGS
CODE
8HN
6HN 1/2" x 1/2" NPT hex nipple 1" "E" length
1/2" x 1/2" NPT hex nipple 1" "E" length
DESCRIPTION
6. SHEATH MOUNTING FITTINGS
00
CODE
No Fitting
DESCRIPTION
Insert three digit sheath length ("X" Dimension) in inches
5. "X" DIMENSIONS
EXPLOSION PROOF APPROVEDFIXED ELEMENT RTD ASSEMBLIES - MODEL 70-22
E-2Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.com
Explosion Proof Fixed Element Thermocouples are for use in U.S. and Canadian hazardous areas. They are designed to extinguish . ames inside the device eliminating the potential for ignition of . ammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependant on connection head type, meet XP Class I, Division 1, Group A, B, C and D; DIP Class II, Division I, Groups E, F, G and Class III, Division 1. They may be installed directly in the process without being inserted into a thermowell. The assemblies feature 316 stainless steel sheaths in various diameter sizes and ungrounded isolated junctions. They are available with or without process mountings and with aluminum or stainless steel explosion proof connection heads.
X
EXPLOSION PROOF APPROVED FIXEDELEMENT THERMOCOUPLE ASSEMBLIES - MODEL 70-82
Acrolab Ltd. PH: 1-800-265-9542 FX: 1-800-465-9674 www.acrolab.comE-3
APPROVEDCSA FILE #217989
FM
Cast iron/aluminum explosion proof head Group C71
74
72
82
81
75T-642B
CODE
6HN
8HN
9HP
8RNDC
8. HEAD MOUNTING FITTINGS
7. SHEATH MOUNTING FITT