OverviewGreat classic design, the CLUBHOUSE offers practical areas of separation between living and sleeping. With two bedrooms, a toilet laundry combo and open plan kitchen living area, this attractive ‘L’ shaped shack comes with a Double Skillion roof for a modern aesthetic. Build a deck within the ‘L’ and you have a great entertaining space. The CLUBHOUSE gives you options a plenty with its classic layout and modern style.
Living Space: 57.99m2
Total Area: 57.99m2
x1x2 x1
CLUBHOUSESkillion Roof
What Back Yard Shacks Supply With Your Shack• Complete building kit to lockup stage using 100% BlueScope materials, including
– frame, cladding, roofing, external doors & windows. (Note: internal fixtures, internal doors plasterboard, kitchens, bathrooms, laundry’s etc are not included).
• Delivery to your site.
• Full engineering plans for frames, roof, sub floor or slab (for Region C2 and N3 wind code areas, this covers from Tasmania to Cairns, to WA excluding Norwest WA).
• Full architectural elevations ready for submission to council.
• Indicative electrical and plumbing plans for DIY.
• Engineering plans for soil classifications A&S, M & MD.
3 Swanston Rd Launceston - 6339 44891 Bass Hwy Roundhill Burnie - 6432 366864 Channel Hwy Kingston - 6229 1790
BACKYARD SHACKS
6180
4180
8060
3780
7670
6670
9360
6270
16950
1113
0
16550
9140
9960
7770
11270
7860
7560
8270
1218 ASW
2124 ASD
REF
HPS
VB
SHR
ENS
LIVINGWC
0906 ASW
SHRWC
WM
REF
HP
S
0906 ASW
1215
ASW
1215
ASW
1215
ASW
BED
AREAS (THE FLAT):TOTAL AREA: 30.46 sqm
ENS
STUDIO THE FLAT
ROBE 920
820 820
VB
KITC
HENLIVING
AREAS (STUDIO):TOTAL AREA: 25.83 sqm
920
820 820
REF
ROBE
BED 1
LIVING
HP S
SHR
WC
WM
BATH
VB
1215 ASW
HOBBY HUT
REFS
920
920
SHR
WCWM
BATHVB920 CSD
BED 1
BED 2
LIVING/DINING
KITCHEN
0912 ASW 1215 ASW
1218 ASW2124 ASD
1218
ASW
1215
ASW
12
15 A
SW
TEENAGE ESCAPE
AREAS (HOBBY HUT):TOTAL AREA: 51.15 sqm
AREAS (TEENAGE ESCAPE):TOTAL AREA: 58.68 sqm
920LIN
920
S
920
920
1215 ASW 1215 ASW
2124 ASD
1215 ASW 1218 ASW 1218 ASW 1215 ASW
DINING
LIVING
BED 2BED 1
0912
ASW
WT
WMVB
SHR
BAT
H
WC
LIVING
DINING
BED 1 BED 2
BED 3LDRY
BATH
ROBE 82
082
0
2124 ASD 1215 ASW 1215 ASW 0912 ASW 920
1218 ASW 1218 ASW 1218 ASW 1215 ASW
920
920
920
WEEKENDERRETREAT
3.0 X 3.0 2.7 X 2.8
2.4 X 3.6 3.8 X 4.0
FLOOR PLAN FLOOR PLAN FLOOR PLAN
1218
ASW
2.9 X 3.0
2.9 X 3.0
6.0 X 4.2
FLOOR PLAN
820820ROBE
820 820
ROBE820 820
LIN
920
4.3 X 4.2
7.6 X 4.2
3.4 X 3.0 3.0 X 3.0
3.0 X 3.0
920
820 820
820
820 REF
0912
ASW
WT
WM
BED 3 BED 4LDRY
3.6 X 2.7
820820
3.0 X 2.6
3.2 X 2.8
3.5 X 5.9
3.9 X 3.8
WIR0906
ASW
BATH
WCENS
SHRVBBATH
VBSHR
WC
AREAS (WEEKENDER):LIVING: 133.58 sqmVERANDAH: 27.12 sqmTOTAL AREA: 160.70 sqm
AREAS (RETREAT):LIVING: 124.78 sqmVERANDAH: 26.48 sqmTOTAL AREA: 151.26 sqm
FLOOR PLANFLOOR PLAN
4.3 X 5.8
1218 ASW 0912 ASW
HP
HP
920
920
920 920
920
920
920
920
920
920
ROBE ROBE
ROBE
ENT.
VERANDAH
1215
ASW
920
ENT.
VERANDAH
1215 ASW 1218 ASW 1215 ASW
1215 ASW
2124 ASD
ENTERTAINER
920
ROBE
WM
VB
REF
S
HP
BED 1
DINING
LIVING
BED 2
BED 3
KITCHEN
BATH
3.1 X 3.1
3.1 X 3.0
3.1 X 3.0
3.5 X 6.0
FLOOR PLAN
AREAS (ENTERTAINER):LIVING: 63.25 sqmVERANDAH: 9.13 sqmTOTAL AREA: 77.38 sqm
920
920
0912
ASW
SHRWC
1215 ASW
VERANDAH
920
920
920 REF
S
HP
SHR
WC
WM
BATHVB
KITC
HENLIVING/DINING
1215 ASW 1218 ASW
2124 ASD 1218 ASW
1215
ASW
0912
ASW
1215 ASW
BED 1
BED 2
920
CLUBHOUSE
AREAS (CLUBHOUSE):TOTAL AREA: 57.99 sqm
920
REF
720
920
920
1215 ASW 1215 ASW
1218 ASW 1215 ASW
1218
ASW
2124
ASD
S
HP
SHR
WC
BATH
VB
BED 2 BED 1
0912
ASW
920 CSD
OUTBACK
LIVING
DINING
KITCHEN
AREAS (OUTBACK):TOTAL AREA: 65.52 sqm
WT WMRO
BE
3.4 X 2.7
3.4 X 2.7
92092
0RO
BE
7.0 X 4.0 92
0
920
CSD
2.9 X 2.9
1218 ASW
KITCHEN
2.9 X 2.9
4.0 X 4.1
3.2 X 2.8
FLOOR PLAN FLOOR PLAN
720
KITCHEN
KITCHEN
DINING
L'DRY
LIN
EN
REF
KITCHEN
HP
920
920
1218 ASW
WC
Things You’ll Need• Site Plan – A site plan is required for a building application submission
to council.
• Soil Test – For soil classifications other than above, consult a local engineer to provide RC Slab/Footing engineering to suit your site.
• House Energy Rating Report – The BCA (Building Code of Australia) now require a house energy rating report from your respective state. QLD, VIC, TAS, SA, NT & WA all use measures adopted from the BCA regulations, with the exception of NSW. NSW operates its own Building Sustainability Index or BASIX.
• Local Building Certifier or Council Certifier – Home-owners are responsible for appointing a Licensed Building Certifier (Building Surveyor) or council certifier.
• A plumbing and Electrical Certifier – to ensure the plumbing drainage and electrical plans comply with prescribed standards. Certifiers must be licensed.
• Possible DA (Development Approval) from Local Council – You may need to submit a DA to the Local Planning and Land Authority or Council for approval.
• Mandatory BA (Building Approval) – A BA application must be lodged with the permit authority or local council.
3 Swanston Rd Launceston - 6339 44891 Bass Hwy Roundhill Burnie - 6432 366864 Channel Hwy Kingston - 6229 1790