+ All Categories
Home > Documents > A- Inch B- Inch F- Inch D- Inch E- Inch

A- Inch B- Inch F- Inch D- Inch E- Inch

Date post: 08-Apr-2022
Category:
Upload: others
View: 15 times
Download: 0 times
Share this document with a friend
5
B 2" 50.79 32" 813.50 16" 407 28" 711.50 D F 4" 102 10" 254.25 A 228. 9" 5 0 Telescopic Leg Range From bottom of glass: 10''-19 '' Flare Front Metal Frame Rev 4 Model 45 50 60 70 80 100 A- Inch 45 9/16 52 5/16 62 2/16 72 3/16 84 9/16 101 8/16 B- Inch 41 5/16 48 57 13/16 67 11/16 80 1/16 97 3/16 F- Inch 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 D- Inch 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 E- Inch 4x6 5x8 5x8 5x8 5x8 5x8 Fireplace Dimensions
Transcript
Page 1: A- Inch B- Inch F- Inch D- Inch E- Inch

B

2"

50.7

9

32

"8

13

.50

16

"4

07

28

"7

11

.50

D

F

4"

102

10

"2

54

.25

A

228

.9

" 5 0

Telescopic Leg RangeFrom bottom of glass: 10''-19''

Flare Front Metal FrameRev 4

Model 45 50 60 70 80 100

A- Inch 45 9/16 52 5/16 62 2/16 72 3/16 84 9/16 101 8/16

B- Inch 41 5/16 48 57 13/16 67 11/16 80 1/16 97 3/16

F- Inch 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16

D- Inch 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16

E- Inch 4x6 5x8 5x8 5x8 5x8 5x8

Fireplace Dimensions

Page 2: A- Inch B- Inch F- Inch D- Inch E- Inch

Appliance Location

4" min.102 min.

1" min.

25 min. 2 "min.

51 min.

Clearances below are to non-combustible materials.

Chimney Installation

Horizontal Termination Vertical Termination

For 5 x 8 vent size create 10'' x 12'' vent termination opening

For 5 x 8 vent size create 10'' x 10'' vent termination opening

10"254

12"305

10"254

4"m

ax.

10

2m

ax.

2"m

in.

51

min

.

10"

25

4

Page 3: A- Inch B- Inch F- Inch D- Inch E- Inch

Flat Vs. L Shape Installation For Flare Front Fireplace

Flat Installation Example L Shape Installation Example

4"102 Max. Shelf Width

Heat Release and Air Intakes

The following sizes MUST be maintained for the upper heat release:For fireplaces sized 80” & 100”– vent area must be at least 200 square inches.For fireplaces sized 60” & 70” - vent area must be at least 140 square inches.For fireplace sized 50” and below - vent area must be at least 100 square inches.

The following sizes MUST be maintained for the lower air intake:For fireplaces sized 80” & 100” – vent area must be at least 100 square inches.For fireplaces sized 60” & 70” - vent area must be at least 70 square inches.For fireplaces sized 50” and below - vent area must be at least 50 square inches.For See Through and Room Definer fireplaces, the air intake requirements are double.NOTE: Openings above for Heat Release and Air Intake are measured for open air space. NOTE: On all See Through and Room Definer units the air intake must be doubled

Page 4: A- Inch B- Inch F- Inch D- Inch E- Inch

Metal Framing Dimensions

Rev 04

NOTE: Dimension ‘Y’ uses legs at default lowest height 4” below the unit with glass beginning 10” above the floor. Increase leg height and Y dimension for higher viewing window. All framing and finishing must be secured to your projects back wall, ceiling or floor, and must never bear weight on the fireplace in any circumstance. For more information reference the Installation Manual

Z

Y

X

Metal stud with Non-

Combustible Back

Wall

Inch 46 9/16 32 8/16

mm 1169 1029

Inch 53 5/16 32 8/16

mm 1354 1029

Inch 63 2/16 32 8/16

mm 1603 1029

Inch 73 3/16 32 8/16

mm 1853 1029

Inch 85 9/16 32 8/16

mm 2173 1029

Inch 102 8/16 32 8/16

mm 2604 1029

4524 1/1620 1/16

510 611

Recess Installation ( 4" Max)

ZX Y

Flat Installation

6020 1/16

510

24 1/16

611

5020 1/16

510

24 1/16

611

8020 1/16

510

24 1/16

611

7020 1/16

510

24 1/16

611

10020 1/16

510 611

24 1/16

Page 5: A- Inch B- Inch F- Inch D- Inch E- Inch

Metal Framing Materials &

Clearances

Rev 04

EXAMPLE OF CLEARANCES TO SIDES AND BACK


Recommended