+ All Categories
Home > Documents > A Reliable Transmission Protocol for ZigBee-Based Wireless Patient Monitoring

A Reliable Transmission Protocol for ZigBee-Based Wireless Patient Monitoring

Date post: 25-Feb-2016
Category:
Upload: harper
View: 50 times
Download: 0 times
Share this document with a friend
Description:
A Reliable Transmission Protocol for ZigBee-Based Wireless Patient Monitoring. IEEE JOURNALS Volume: 16 , Issue:1 Shyr-Kuen Chen, Tsair Kao, Chia-Tai Chan, Chih-Ning Huang, Chih-Yen Chiang, Chin-Yu Lai, Tse-Hua Tung, and Pi-Chung Wang. Presenter: Yu-Ming Chen - PowerPoint PPT Presentation
Popular Tags:
32
A Reliable A Reliable Transmission Transmission Protocol for ZigBee- Protocol for ZigBee- Based Wireless Based Wireless Patient Monitoring Patient Monitoring IEEE IEEE JOURNALS JOURNALS Volume: 16 , Issue:1 Volume: 16 , Issue:1 Shyr-Kuen Chen, Tsair Kao, Chia-Tai Shyr-Kuen Chen, Tsair Kao, Chia-Tai Chan, Chan, Chih-Ning Huang, Chih-Yen Chiang, Chin- Chih-Ning Huang, Chih-Yen Chiang, Chin- Yu Lai, Yu Lai, Tse-Hua Tung, and Pi-Chung Wang Tse-Hua Tung, and Pi-Chung Wang Presenter: Yu-Ming Chen Adviser: Hung-Chi Yang
Transcript
Page 1: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

A Reliable Transmission A Reliable Transmission Protocol for ZigBee-Protocol for ZigBee-Based Wireless Patient Based Wireless Patient MonitoringMonitoring

IEEEIEEE JOURNALS JOURNALSVolume: 16 , Issue:1 Volume: 16 , Issue:1

Shyr-Kuen Chen, Tsair Kao, Chia-Tai Chan, Shyr-Kuen Chen, Tsair Kao, Chia-Tai Chan, Chih-Ning Huang, Chih-Yen Chiang, Chin-Yu Lai, Chih-Ning Huang, Chih-Yen Chiang, Chin-Yu Lai,

Tse-Hua Tung, and Pi-Chung WangTse-Hua Tung, and Pi-Chung Wang

Presenter: Yu-Ming Chen Adviser: Hung-Chi Yang

Page 2: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

OutlineOutlineIntroductionIntroductionRelated WorkRelated WorkReliable Transmission ProtocolReliable Transmission ProtocolFall Monitoring systemFall Monitoring systemSimulation and implementation ResultsSimulation and implementation ResultsConclusionConclusion

Page 3: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTIONThe global elderly population is fast The global elderly population is fast

growing and will outnumber the population growing and will outnumber the population of children in near future. of children in near future.

The changes brought about by the aging The changes brought about by the aging society include an increasing demand for society include an increasing demand for caretaking; thus, patient monitoring caretaking; thus, patient monitoring systems are gaining their importance in systems are gaining their importance in reducing the need for human resources.reducing the need for human resources.

Page 4: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTION In this paper, we present a reliable In this paper, we present a reliable

transmission protocol based on anycast transmission protocol based on anycast routing for wireless patient monitoring.routing for wireless patient monitoring.

Page 5: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTION In this paper, we present a reliable In this paper, we present a reliable

protocol of packet forwarding that protocol of packet forwarding that transmits emergency messages with vital transmits emergency messages with vital signs on a multihop ZigBee network.signs on a multihop ZigBee network.

Page 6: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTIONWe deploy multiple data sinks in a ZigBee We deploy multiple data sinks in a ZigBee

network.network.

Our protocol uses anycast to find the Our protocol uses anycast to find the nearest available data sink.nearest available data sink.

When the path to the original data sink When the path to the original data sink fails, our protocol automatically selects fails, our protocol automatically selects another data sink as destination. another data sink as destination.

Page 7: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTIONAs compared with multicast/broadcast

approaches, our protocol significantly reduces the traffic overhead while maintaining the reliability at the same level.

Page 8: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTIONWe implement a ZigBee device for fall We implement a ZigBee device for fall

monitoring, which integrates fall detection monitoring, which integrates fall detection indoor positioning, and ECG monitoring.indoor positioning, and ECG monitoring.

When the triaxial accelerometer of our When the triaxial accelerometer of our device detects a fall, the current position of device detects a fall, the current position of the patient is generated and transmitted to the patient is generated and transmitted to a data sink through a ZigBee network. a data sink through a ZigBee network.

Page 9: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

INTRODUCTIONINTRODUCTION In order to clarify the situation of the fallen In order to clarify the situation of the fallen

patient, 4-s ECG signals are transmitted patient, 4-s ECG signals are transmitted along with the emergency message.along with the emergency message.

Page 10: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORKA Communication ModesA Communication Modes Data transmission can be categorized into Data transmission can be categorized into

four modes, namely unicast, multicast, four modes, namely unicast, multicast, broadcast, and anycast.broadcast, and anycast.

Page 11: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORK

B. Wireless Patient Monitoring SystemB. Wireless Patient Monitoring System This framework uses four routing This framework uses four routing

schemes(multicast, reliable multicast, schemes(multicast, reliable multicast, broadcast, and reliable broadcast)broadcast, and reliable broadcast)

Page 12: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORK

B. Wireless Patient Monitoring SystemB. Wireless Patient Monitoring System Using IEEE 802.15.4 standard for ECG, Using IEEE 802.15.4 standard for ECG,

the maximum payload size only allow up the maximum payload size only allow up to 118 samples per frame bringing the to 118 samples per frame bringing the accumulation delay to 236ms. accumulation delay to 236ms.

Page 13: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

802.15.4802.15.4

Page 14: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORK

B. Wireless Patient Monitoring SystemB. Wireless Patient Monitoring System The minimum data sampling rate of 1 The minimum data sampling rate of 1

sample per frame result in an accumulated sample per frame result in an accumulated delay of 2 ms.delay of 2 ms.

Page 15: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORKB. Wireless Patient Monitoring SystemB. Wireless Patient Monitoring System

Previous schemes tend to use broadcast Previous schemes tend to use broadcast or multicast schemes to achieve message or multicast schemes to achieve message delivery in a multihop wireless network.delivery in a multihop wireless network.

Page 16: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORK B. Wireless Patient Monitoring SystemB. Wireless Patient Monitoring System

Although the number of transmission hops and Although the number of transmission hops and traffic overhead can be reduced by using excess traffic overhead can be reduced by using excess transmission power, the collision domain is also transmission power, the collision domain is also enlarged to severely degrade the transmission enlarged to severely degrade the transmission efficiency of MAC layer.efficiency of MAC layer.

Page 17: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELATED WORKRELATED WORK B. Wireless Patient Monitoring SystemB. Wireless Patient Monitoring System We combine anycast with a reliable transmission We combine anycast with a reliable transmission

mechanism to improve the efficiency of message mechanism to improve the efficiency of message transmission in this paper. transmission in this paper.

Since our scheme does not rely on in creasing Since our scheme does not rely on in creasing transmission power, the power efficiency of our transmission power, the power efficiency of our scheme can be improved as well.scheme can be improved as well.

Page 18: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELIABLE TRANSMISSION RELIABLE TRANSMISSION PROTOCOLPROTOCOL

Sensor NodeSensor Node

Router NodeRouter Node

Data receiverData receiver

Page 19: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELIABLE TRANSMISSION RELIABLE TRANSMISSION PROTOCOLPROTOCOL

A. Sensor NodeA. Sensor Node

Page 20: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELIABLE TRANSMISSION RELIABLE TRANSMISSION PROTOCOLPROTOCOL

B. Router NodeB. Router Node

Page 21: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

RELIABLE TRANSMISSION RELIABLE TRANSMISSION PROTOCOLPROTOCOL

C. Data ReceiverC. Data Receiver

Page 22: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

FALL MONITORING SYSTEMFALL MONITORING SYSTEM

SVM: SSVM: Sum Vector Magnitude of accelerationum Vector Magnitude of acceleration

Page 23: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring
Page 24: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

SIMULATION AND SIMULATION AND IMPLEMENTATION RESULTSIMPLEMENTATION RESULTS

A. Simulation ResultsA. Simulation Results

Page 25: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring
Page 26: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring
Page 27: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring
Page 28: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

SIMULATION AND SIMULATION AND IMPLEMENTATION RESULTSIMPLEMENTATION RESULTS

B. Implementation ResultsB. Implementation Results

Page 29: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring
Page 30: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring
Page 31: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

CONCLUSIONCONCLUSION This paper presents a reliable anycast routing This paper presents a reliable anycast routing

protocol for ZigBee-based wireless patient protocol for ZigBee-based wireless patient monitoring.monitoring.

A broken path can be recovered in a short A broken path can be recovered in a short latency. latency.

We demonstrate that our scheme can improve We demonstrate that our scheme can improve the feasibility of wireless patient monitoring the feasibility of wireless patient monitoring systems.systems.

Page 32: A  Reliable Transmission Protocol for ZigBee-Based Wireless  Patient  Monitoring

Recommended