+ All Categories
Home > Documents > A Very Forward Proton Spectrometer for H1

A Very Forward Proton Spectrometer for H1

Date post: 08-Jan-2016
Category:
Upload: katima
View: 42 times
Download: 2 times
Share this document with a friend
Description:
A Very Forward Proton Spectrometer for H1. Pierre Van Mechelen Universiteit Antwerpen (UIA). Participating Groups. University of Antwerp (UIA), Belgium T. Anthonis, E. A. De Wolf, P. Van Mechelen Inter-University Institute for High Energies (ULB-VUB), Brussels, Belgium - PowerPoint PPT Presentation
Popular Tags:
17
LISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002 A Very Forward Proton A Very Forward Proton Spectrometer for H1 Spectrometer for H1 Pierre Van Mechelen Pierre Van Mechelen Universiteit Antwerpen (UIA) Universiteit Antwerpen (UIA)
Transcript
Page 1: A Very Forward Proton Spectrometer for H1

LISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

A Very Forward ProtonA Very Forward ProtonSpectrometer for H1Spectrometer for H1

Pierre Van MechelenPierre Van Mechelen

Universiteit Antwerpen (UIA)Universiteit Antwerpen (UIA)

Page 2: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Participating GroupsParticipating Groups

University of Antwerp (UIA), BelgiumUniversity of Antwerp (UIA), BelgiumT. Anthonis, E. A. De Wolf, P. Van MechelenT. Anthonis, E. A. De Wolf, P. Van Mechelen

Inter-University Institute for High Energies (ULB-Inter-University Institute for High Energies (ULB-VUB), VUB),

Brussels, BelgiumBrussels, BelgiumL. Favart, X. Janssen, D. Johnson, P. Marage, R. RoosenL. Favart, X. Janssen, D. Johnson, P. Marage, R. Roosen

University of Hamburg II, GermanyUniversity of Hamburg II, GermanyV. Blobel, F. Büsser, V. Jemanov, A. Meyer, B. Naroska,V. Blobel, F. Büsser, V. Jemanov, A. Meyer, B. Naroska,

F. Niebergall, J. Schütt, H. Spitzer, R. van StaaF. Niebergall, J. Schütt, H. Spitzer, R. van Staa

University of Lund, SwedenUniversity of Lund, SwedenL. Jönsson, H. Jung, U. MjörnmarkL. Jönsson, H. Jung, U. Mjörnmark

University of Birmingham, UKUniversity of Birmingham, UKP. NewmanP. Newman

Page 3: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Diffraction Physics at HERADiffraction Physics at HERA

• HERA I (1992-2000): HERA I (1992-2000):

– large fraction (~10%) of “large rapidity gap” eventslarge fraction (~10%) of “large rapidity gap” events

– strong theoretical interest (understanding in QCD)strong theoretical interest (understanding in QCD)

– measurements of measurements of FF22DD, incl. final states, jets, charm, excl. VM, incl. final states, jets, charm, excl. VM

– results: soft/hard transition, gluon dominance, DGLAP results: soft/hard transition, gluon dominance, DGLAP consistencyconsistency

– limitations: rapidity gap selection yields large systematic errors, limitations: rapidity gap selection yields large systematic errors, low statistics, limited low statistics, limited t t and and measurement measurement

• HERA II (2001-2006):HERA II (2001-2006):

– major upgrade of the H1 detectormajor upgrade of the H1 detector

– high luminosity regime high luminosity regime need for efficient VFPS-trigger need for efficient VFPS-trigger

– need for clean selection by tagging the scattered protonneed for clean selection by tagging the scattered proton

– need for measurement of proton momentum (need for measurement of proton momentum (xxIPIP ,, t t, , ))

Page 4: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

The H1 Forward Proton The H1 Forward Proton SpectrometerSpectrometer• Horizontal stations:Horizontal stations:

– at 60 m and 80 m from I.P.at 60 m and 80 m from I.P.

– acceptance of a few % at acceptance of a few % at high |high |t t | and low | and low xxIPIP

• Vertical stations:Vertical stations:

– at 81 m and 90 m from I.P.at 81 m and 90 m from I.P.

– large acceptance at low |large acceptance at low |tt | and large | and large xxIPIP

• Measurement of Measurement of FF22LPLP::

year lumi events FPS-V 1995 1.4 pb-1 1661 FPS-H 1999/2000 28.8 pb-1 3100

Page 5: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

VFPS LocationVFPS Location

• VFPS location is optimised for VFPS location is optimised for acceptance acceptance 220m NL 220m NL

• Proton beam is approached Proton beam is approached horizontally (use HERA bend)horizontally (use HERA bend)

• Bypass is needed to re-route Bypass is needed to re-route the cold beam linethe cold beam line

xxIPIP = 0.01 = 0.01

H1

ZEUS

VFPS

HERMES

HERA-B

present FPS VFPS

Page 6: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Bypass of Cold Beam LineBypass of Cold Beam Line• Cold section HPNL-220:Cold section HPNL-220:

– modification of 10 m drift segment with easy accessmodification of 10 m drift segment with easy access

– p p -beam above -beam above e e -beam-beam

– horizontal bypass for helium and superconductor lineshorizontal bypass for helium and superconductor lines

– new (warm) beam pipenew (warm) beam pipe

Page 7: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

VFPS DetectorsVFPS Detectors

• VFPS detectors similar to FPS:VFPS detectors similar to FPS:

– 2 “Roman Pot” stations equipped 2 “Roman Pot” stations equipped with with 2 scintillating fibre detectors each2 scintillating fibre detectors each

– 1 fibre detector measures both 1 fibre detector measures both u u - - and and v v - co-ordinates- co-ordinates

• 5 fibres/light guide 5 fibres/light guide 8.2 photo- 8.2 photo-electrons electrons 99.4% detection 99.4% detection efficiencyefficiency

• Staggered fibres properties:Staggered fibres properties:diameter 480 µm pitch 340 µm cladding 30 µm theoretical resolution 63 µm prototype test resolution 94 µm

Page 8: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Triggering Diffractive DIS at Triggering Diffractive DIS at HERA-IIHERA-II• HERA-I strategy:HERA-I strategy:

– inclusive trigger based on inclusive trigger based on backward calorimeter (SPACAL) backward calorimeter (SPACAL) and vertex requirement and vertex requirement (MWPC)(MWPC)

– off-line rapidity gap selection off-line rapidity gap selection

• HERA-II: HERA-II:

– factor 5 increase in luminosityfactor 5 increase in luminosity

– factor 2 increase in beam factor 2 increase in beam currents currents

– inclusive triggers are pre-scaledinclusive triggers are pre-scaled

• Rapidity gap trigger unfeasibleRapidity gap trigger unfeasible

• Level-1 VFPS trigger neededLevel-1 VFPS trigger needed

HERA-I 100 Hz HERA-I < 174° 30 Hz HERA-II < 174° 175 Hz

FPS HERA-I 10 kHz FPS HERA-II 20 kHz VFPS HERA-II 60 kHz

SPACAL/MWPC trigger rates:

(V)FPS trigger rates:

coincidence rates:

background 1.0 Hz physics 0.4 Hz total 1.4 Hz

Page 9: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

• Linear beam transport:Linear beam transport:

• Non-linear corrections:Non-linear corrections:

– non-linear effects in energy deviation non-linear effects in energy deviation xxIPIP

– sextupolessextupoles

– offset, tilted magnetsoffset, tilted magnets

Simulation StudiesSimulation Studies

IP

xxxx

xxx

x

x

x

DTT

DTT

x

x

0

100 0

0

02221

1211

diffractiveep scattering

beam spreadand divergence at

I.P.

position, slope and

energy at VFPS

beam optictransport matrix

Page 10: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

AcceptanceAcceptance

• Simulation includes detailed Simulation includes detailed description of beam pipedescription of beam pipe

• HERA machine crew agreed to HERA machine crew agreed to steer proton beam away from steer proton beam away from critical acceptance losscritical acceptance loss

• Detectors approach beam up to Detectors approach beam up to “12-sigma” from inside HERA “12-sigma” from inside HERA ring ring + 3 mm “coasting beam + 3 mm “coasting beam margin”margin”

• Acceptance range:Acceptance range: FPS-H FPS-V VFPS |t |- range 0.2 0.4 0 0.15 0 0.25 xIP - range 10-5 10-2 0.05 0.15 0.01 0.02 local acc. < 30% ~ 100% ~ 100%

Page 11: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

ReconstructionReconstruction

• Reconstruction fit:Reconstruction fit:

where where ccijij is a covariance matrix containing: is a covariance matrix containing:

– beam covariancebeam covariance

– fibre detector resolutionfibre detector resolution

jiyxIPjjijyxIPii xxxcxxx

,

12 ,,,,

Page 12: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

ResolutionResolution

• Resolution is dominated by beam covariance (but still Resolution is dominated by beam covariance (but still sensitive to fibre detector resolution)sensitive to fibre detector resolution)

• xxIPIP resolution is competitive with reconstruction of resolution is competitive with reconstruction of xxIPIP by H1 by H1

• ~ 4 bins in |~ 4 bins in |t t ||

• ~ 15 bins in ~ 15 bins in for | for |tt | > 0.2 GeV | > 0.2 GeV22

Page 13: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

• Relative positioning of Relative positioning of detectors versus nominal detectors versus nominal proton beamproton beam

• Exploit kinematic peak and Exploit kinematic peak and xxIP IP -measurement by H1-measurement by H1

• Calibration fit:Calibration fit:

• Alignment precision of ~100 Alignment precision of ~100 m is feasiblem is feasible

• Alternative fits are possible Alternative fits are possible with e.g. elastic with e.g. elastic mesonsmesons

AlignmentAlignment

2

21

2

2

2

22

1HIPIPyx xx

HIPIPyx xx

Page 14: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Expected ResultsExpected Results

• Inclusive diffraction:Inclusive diffraction:

– luminosity: 350 pbluminosity: 350 pb-1-1 (3 years of (3 years of HERA-II running, 50% VFPS HERA-II running, 50% VFPS operation efficiency)operation efficiency)

– test of hard scattering fact.:test of hard scattering fact.:FF22

D D ((, Q, Q 22) at fixed ) at fixed xxIPIP , |, |t t ||

– uncorrelated systematic errors uncorrelated systematic errors can approach the level of can approach the level of FF22 (few (few %)%)

– event yields:event yields:

event sample no coasting beam coasting beam acceptance > 80% 1,100,000 390,000 0 < |t| < 0.2 GeV2 1,800,000 810,000 0.2 < |t| < 0.4 GeV2 330,000 160,000 0.4 < |t| < 0.6 GeV2 47,000 23,000 0.6 < |t| < 0.8 GeV2 6,000 3,000

Page 15: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Expected ResultsExpected Results

• Hadronic final states:Hadronic final states:

– Open charm production:Open charm production:• 1996/97 1996/97 D*D* analysis yielded 46 analysis yielded 4610 10

ev.ev.

• full HERA-I data sample: factor 2-3full HERA-I data sample: factor 2-3

• HERA-II/VFPS expectation: 380 ev.HERA-II/VFPS expectation: 380 ev.

– Diffractive dijet electroproduction:Diffractive dijet electroproduction:• 1996/97 dijet analysis yielded 2500 1996/97 dijet analysis yielded 2500

ev.ev.

• HERA-II/VFPS expectation: 22900 HERA-II/VFPS expectation: 22900 ev.ev.

– Diffractive dijet photoproduction:Diffractive dijet photoproduction:• HERA-II/VFPS expectation: HERA-II/VFPS expectation:

• eTag-6 (eTag-6 (WW = 275 GeV): 1400 ev. = 275 GeV): 1400 ev.

• eTag-40 (eTag-40 (WW = 140 GeV): 20000 ev. = 140 GeV): 20000 ev.

open charm production

dijet electroproduction

Page 16: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

Expected ResultsExpected Results

• Azimuthal asymmetryAzimuthal asymmetry

– angle between proton and electron scattering planes (angle between proton and electron scattering planes () ) gives a handle on gives a handle on T T and and LL and their interference terms: and their interference terms:

– 15 bins with each 10,000 events!15 bins with each 10,000 events!

– study asymmetry as a function of study asymmetry as a function of , , QQ 22

• Deeply Virtual Compton ScatteringDeeply Virtual Compton Scattering

– only 25 DVCS observed in 1997only 25 DVCS observed in 1997

– HERA-II/VFPS expectation: 3600 events (HERA-II/VFPS expectation: 3600 events (QQ 22 > 8 GeV > 8 GeV22))

– VFPS adds to H1-triggered DVCS, mostly at low VFPS adds to H1-triggered DVCS, mostly at low WW, low , low QQ 22

2coscos12 TTLTLT

D

dd

Page 17: A Very Forward Proton Spectrometer for H1

Pierre Van MechelenLISHEP 2002 – Rio de Janeiro, Brazil – February 4-8, 2002

TimelineTimeline

ConclusionConclusion

• VFPS mandatory to trigger diffraction at HERA-IIVFPS mandatory to trigger diffraction at HERA-II

• Very good acceptance in narrow window around Very good acceptance in narrow window around xxIPIP = 0.01 = 0.01

• Good resolution on reconstructed proton momentum will Good resolution on reconstructed proton momentum will allow exciting physics analysesallow exciting physics analyses

• DESY-PRC approved the project in October 2001DESY-PRC approved the project in October 2001

• Bypass and VFPS construction are on scheduleBypass and VFPS construction are on schedule

• Insertion in HERA machine is foreseen for early 2003 Insertion in HERA machine is foreseen for early 2003 shutdownshutdown

• Data taking from 2004 to 2006...Data taking from 2004 to 2006...


Recommended